Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Ciênc. rural (Online) ; 47(8): 1-7, 2017. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1480033

Resumo

ABSTRACT: Long bone fractures are commonly in surgery routine and several bone imobilization techniques are currently available. Technological progress has enabled to use low cost materials in surgical procedures. Thus, the aim of this study was to evaluate the applicability of polyamide 12 rods, solid and hollow in swine femurs, comparing them through flexion strength. This study had as second aim to fix the locking errors, commom place in interlocking nails, once polyamide 12 allows perforation in any direction by orthopaedic screw. Six groups were used: G1 - eight whole swine femurs; G2 - eight whole swine femurs with drilled medullary canal; G3 - two solid polyamide 12 rods; G4 - two hollow polyamide 12 rods; G5 - eight osteotomized drilled swine femurs with a solid polyamide 12 rod implanted in the medullary canal and locked by four 316L stainless steel screws; and G6 - similar to G5 but using hollow rods instead of solid ones. No significant differences were observed for the modulus of rupture between solid and hollow rods, demonstrating that both rods had similar performances. These results led to the speculation that the addition of other polymers to the hollow rods could increase their strength and thus the bone-implant system. Furthermore, the comparison between G1, G5 and G6 could be analyzed using the finite element method in future. New polymeric materials may be developed based on the data from this study, strengthening the bone-implant system and making possible screws to be placed in any direction, nullifying the detrimental forces on the fracture site.


RESUMO: Fraturas em ossos longos são comumente encontradas na rotina cirúrgica e várias técnicas de imobilização óssea estão disponíveis. Com o avanço tecnológico, tornou-se viável utilizar materiais de baixo custo nos procedimentos, portanto esse estudo objetivou avaliar a aplicabilidade de hastes de poliamida 12, sólidas e vazadas, implantadas em fêmures suínos, comparando-as segundo as forças de flexão e aos erros de bloqueio, corriqueiros nesse implante, uma vez que a poliamida 12 permite sua perfuração em qualquer direção por meio de parafusos ortopédicos. Seis grupos foram usados: G1 - oito fêmures suínos íntegros; G2 - oito fêmures suínos, fresados intramedularmente; G3 - duas hastes maciças de poliamida 12; G4 - duas hastes vazadas de poliamida 12; G5 - oito fêmures suínos osteotomizados e fresados, com haste de poliamida 12 maciça implantada no canal medular e bloqueada com quatro parafusos de aço inoxidável 316L e G6 - diferente de G5 apenas por utilizar hastes vazadas. Não foram observadas diferenças significativas no módulo de ruptura entre hastes sólidas e vazadas, demonstrando que ambas apresentaram o mesmo desempenho. Estes resultados levaram à especulação de que adicionar outros polímeros às hastes vazadas aumentaria sua força e, portanto, do sistema osso-implante. Além disso, a comparação entre G1, G5 e G6 poderia no futuro ser analisada utilizando o método dos elementos finitos. Novos polímeros podem ser desenvolvidos baseando-se nos dados deste estudo, reforçando o sistema osso-implante e também possibilitando o uso de perfurações para o bloqueio no transoperatório em qualquer direção, anulando as forças deletérias atuantes no sítio de fratura.


Assuntos
Animais , Fixação Interna de Fraturas , Fraturas do Fêmur/veterinária , Osteotomia/veterinária , Suínos , Fenômenos Biomecânicos
2.
Ci. Rural ; 47(8): 1-7, 2017. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-735379

Resumo

ABSTRACT: Long bone fractures are commonly in surgery routine and several bone imobilization techniques are currently available. Technological progress has enabled to use low cost materials in surgical procedures. Thus, the aim of this study was to evaluate the applicability of polyamide 12 rods, solid and hollow in swine femurs, comparing them through flexion strength. This study had as second aim to fix the locking errors, commom place in interlocking nails, once polyamide 12 allows perforation in any direction by orthopaedic screw. Six groups were used: G1 - eight whole swine femurs; G2 - eight whole swine femurs with drilled medullary canal; G3 - two solid polyamide 12 rods; G4 - two hollow polyamide 12 rods; G5 - eight osteotomized drilled swine femurs with a solid polyamide 12 rod implanted in the medullary canal and locked by four 316L stainless steel screws; and G6 - similar to G5 but using hollow rods instead of solid ones. No significant differences were observed for the modulus of rupture between solid and hollow rods, demonstrating that both rods had similar performances. These results led to the speculation that the addition of other polymers to the hollow rods could increase their strength and thus the bone-implant system. Furthermore, the comparison between G1, G5 and G6 could be analyzed using the finite element method in future. New polymeric materials may be developed based on the data from this study, strengthening the bone-implant system and making possible screws to be placed in any direction, nullifying the detrimental forces on the fracture site.(AU)


RESUMO: Fraturas em ossos longos são comumente encontradas na rotina cirúrgica e várias técnicas de imobilização óssea estão disponíveis. Com o avanço tecnológico, tornou-se viável utilizar materiais de baixo custo nos procedimentos, portanto esse estudo objetivou avaliar a aplicabilidade de hastes de poliamida 12, sólidas e vazadas, implantadas em fêmures suínos, comparando-as segundo as forças de flexão e aos erros de bloqueio, corriqueiros nesse implante, uma vez que a poliamida 12 permite sua perfuração em qualquer direção por meio de parafusos ortopédicos. Seis grupos foram usados: G1 - oito fêmures suínos íntegros; G2 - oito fêmures suínos, fresados intramedularmente; G3 - duas hastes maciças de poliamida 12; G4 - duas hastes vazadas de poliamida 12; G5 - oito fêmures suínos osteotomizados e fresados, com haste de poliamida 12 maciça implantada no canal medular e bloqueada com quatro parafusos de aço inoxidável 316L e G6 - diferente de G5 apenas por utilizar hastes vazadas. Não foram observadas diferenças significativas no módulo de ruptura entre hastes sólidas e vazadas, demonstrando que ambas apresentaram o mesmo desempenho. Estes resultados levaram à especulação de que adicionar outros polímeros às hastes vazadas aumentaria sua força e, portanto, do sistema osso-implante. Além disso, a comparação entre G1, G5 e G6 poderia no futuro ser analisada utilizando o método dos elementos finitos. Novos polímeros podem ser desenvolvidos baseando-se nos dados deste estudo, reforçando o sistema osso-implante e também possibilitando o uso de perfurações para o bloqueio no transoperatório em qualquer direção, anulando as forças deletérias atuantes no sítio de fratura.(AU)


Assuntos
Animais , Suínos , Osteotomia/veterinária , Fraturas do Fêmur/veterinária , Fixação Interna de Fraturas , Fenômenos Biomecânicos
3.
Tese em Português | VETTESES | ID: vtt-208932

Resumo

O tratamento de fraturas ósseas são procedimentos corriqueiros na clínica ortopédica humana e veterinária. As fraturas em ossos longos (p. ex. fêmur, úmero, tíbia) ocorrem com frequência tanto em humanos como em animais domésticos e demandam técnicas específicas de estabilização. Hastes intramedulares, confeccionadas com materiais biocompatíveis, têm sido reconhecidas como adequadas no tratamento de fraturas de ossos longos. O desenvolvimento de artefatos, que apresentem as necessárias características de biocompatibilidade e resistência mecânica às demandas de estabilização óssea, exige o entendimento do comportamento biomecânico do sistema músculo-esquelético. Dessa forma, um projeto de caráter multidisciplinar tem sido desenvolvido por pesquisadores da Universidade Federal de Minas Gerais, utilizando-se dos recursos da Escola de Engenharia, Escola de Veterinária e Escola de Educação Física, Fisioterapia e Terapia Ocupacional. Um estudo do comportamento do conjunto osso-implante, nas mais diversas situações de solicitação mecânica, será realizado em parceria com pesquisadores da Universidade Federal dos Vales do Jequitinhonha e Mucuri. Nesse trabalho, pretende-se desenvolver metodologia que permita melhor entendimento da biomecânica do sistema musculo-esquelético de bovinos jovens, facilitando a monitoração do processo de reabilitação dos animais e possibilitando o aperfeiçoamento dos modelos teóricos utilizados nas simulações computacionais, baseadas no método dos elementos finitos. Serão analisados dados relativos à força de reação do solo, obtidos por meio do uso de plataforma de força, durante o deslocamento ao passo dos animais. Da mesma forma, resultados obtidos em testes in-vivo, a serem realizados, com hastes fabricadas com o material polimérico, serão analisados, a fim de avaliar o comportamento do conjunto osso implante e possibilitar o acompanhamento do processo de reparação da fratura.


The treatment and the reduction of bone fractures are usual procedures in human and veterinary orthopedic clinics. Fractures of long bones (e.g., femur, humerus, tibia) occur frequently both in humans and domestic large animals, requiring specific techniques of stabilization. Intramedullary nails, made from biocompatible materials, have been recognized as suitable for the treatment of long bone fractures. The development of prosthesis, presenting the necessary biocompatibility and mechanical strength to support bone stabilization demands, requires the understanding of the biomechanical behavior of the musculoskeletal system. To investigate the effect of different fixation strategies of the intramedullary interlocking nail (IIN) on the mechanical behavior of a polymeric implant applied for femoral fracture fixation in calves. It was also evaluated the performance of four polymeric materials used for the manufacture of intramedullary nails. Five Holstein male animals with a mean weight (± SD) of 62.8 ± 20.4 kgf and aged 74 ± 15 days were used in this study. Based on the solid model of the femur, sixteen models were built to simulate an oblique simple fracture. The models were divided into four groups, with each group of four models being associated with a different fixation strategy. Models were tested under the same loading condition that simulated a calf in the transition (decubitus position to static position) condition. Maximum bone and implant stresses were compared to yield and rupture stresses of specific materials (polyacetal, polypropylene, polyamide VI and a glass fiber-reinforced polymer). The largest stresses in the implant were found in the screws and at the interface between the screw and the nail. The performance of implants was influenced by the material and fixation strategy. The finite element method (FEM) model analyses demonstrated that all polymeric materials analyzed provided sufficient resistance to tolerate the loading forces imposed on the femur when an adequate fixation strategy was applied.

4.
Acta cir. bras. ; 27(6): 424-429, 2012. tab
Artigo em Inglês | VETINDEX | ID: vti-4294

Resumo

PURPOSE: To conduct a systematized review of the literature about the main methodologies used to evaluate the biomechanical fixation systems with titanium plates in fractures of the mandibular condyle. METHODS: A systematized review of literature was performed in the electronic databases PubMed, EMBASE, LILACS and MEDLINE without restriction of the publication date. The eligibility criteria were laboratory studies involving mandibular condyle fractures, studies using titanium plates, biomechanical studies, in vitro and computational studies involving the finite element method (FEM). RESULTS: Eleven articles that met the eligibility criteria were selected, including seven articles involving in vitro studies and four studies with biomechanical analysis by using FEM. CONCLUSION: Although few articles have used the finite element method, the results of in vitro studies were similar to those found in computational studies, regarding to the stable use of two titanium miniplates.(AU)


OBJETIVO: Realizar uma revisão sistematizada da literatura sobre as principais metodologias empregadas na avaliação biomecânica de sistemas de fixação com placas de titânio em fraturas de côndilo mandibular. MÉTODOS: Foi realizada uma revisão sistematizada da literatura nas bases de dados eletrônicas PubMed, EMBASE, LILACS e MEDLINE sem restrição quanto à data de publicação. Os critérios de elegibilidade foram estudos laboratoriais envolvendo fraturas de côndilo mandibular, estudos utilizando placas de titânio, estudos biomecânicos, estudos in vitro e estudos computacionais envolvendo o método de elementos finitos (MEF). RESULTADOS: Foram selecionados 11 artigos que se enquadraram nos critérios de elegibilidade, incluindo sete artigos envolvendo estudos in vitro e quatro utilizando análise biomecânica através do MEF. CONCLUSÃO: Embora poucos artigos tenham utilizado o método de elementos finitos, os resultados das pesquisas in vitro assemelham-se aos encontrados nos estudos computacionais, com relação ao uso estável de duas miniplacas de titânio.(AU)


Assuntos
Fenômenos Biomecânicos , Titânio/uso terapêutico , Côndilo Mandibular/anatomia & histologia , Fixação de Fratura
5.
Sci. agric ; 68(5)2011.
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1497219

Resumo

A finite element method-based model of a substrate heated by an electric heating cable buried in a thermal isolated container was experimentally validated with root mean square error values of root zone temperature ranging 0.25 to 0.62 ºC. The two-dimensional transient model allowed variations in the physical properties of the substrate with temperature, water content and depth. The operation of nine configurations of a heating cable buried in sand at different depths (50 to 450 mm, at 50 mm intervals) at 200 mm spacing was simulated and assessed. The validated model was used to perform 24-h simulations applying boundary conditions, and substrate moisture content was experimentally obtained at a mean substrate surface temperature of 13.98 ºC. Such simulations reproduced the operation of the heating system by setting a reference temperature of 20 ºC at the control point in the root zone. Burying the heating cable in the surface layers of the substrate caused large temperature gradients and high heat losses through the substrate surface. Accordingly, average temperature in the root zone increased with heating cable depth, up to the 200 mm depth. For greater depths, temperature in the root zone was constant. The ON/OFF control was most effective with the heating cable buried in the root zone and at control point temperatures of 20 ± 1 ºC. Burying the heating cable in the surface layers required higher energy consumption, up to 28 % at 50 mm. The most efficient heating cable depth was 350 mm, with a daily energy consumption of 6750 kJ m-2.

6.
Sci. agric. ; 68(5)2011.
Artigo em Inglês | VETINDEX | ID: vti-440612

Resumo

A finite element method-based model of a substrate heated by an electric heating cable buried in a thermal isolated container was experimentally validated with root mean square error values of root zone temperature ranging 0.25 to 0.62 ºC. The two-dimensional transient model allowed variations in the physical properties of the substrate with temperature, water content and depth. The operation of nine configurations of a heating cable buried in sand at different depths (50 to 450 mm, at 50 mm intervals) at 200 mm spacing was simulated and assessed. The validated model was used to perform 24-h simulations applying boundary conditions, and substrate moisture content was experimentally obtained at a mean substrate surface temperature of 13.98 ºC. Such simulations reproduced the operation of the heating system by setting a reference temperature of 20 ºC at the control point in the root zone. Burying the heating cable in the surface layers of the substrate caused large temperature gradients and high heat losses through the substrate surface. Accordingly, average temperature in the root zone increased with heating cable depth, up to the 200 mm depth. For greater depths, temperature in the root zone was constant. The ON/OFF control was most effective with the heating cable buried in the root zone and at control point temperatures of 20 ± 1 ºC. Burying the heating cable in the surface layers required higher energy consumption, up to 28 % at 50 mm. The most efficient heating cable depth was 350 mm, with a daily energy consumption of 6750 kJ m-2.

7.
Tese em Português | VETTESES | ID: vtt-203046

Resumo

A espondilomielopatia cervical (EMC) é uma afecção que envolve diversas estruturas da coluna vertebral cervical de cães de raças grandes e gigantes, havendo como consequência a compressão da medula espinhal, raízes nervosas, ou ambas. A cirurgia é o tratamento de escolha e diferentes procedimentos cirúrgicos foram propostos para o tratamento da EMC. Na doença disco-associada, o tratamento amplamente utilizado e que conduz a melhores resultados é a distração-fusão, porém, esta técnica pode levar a alterações biomecânicas nos segmentos adjacentes aumentando o risco de lesão do tipo dominó, com consequente degeneração dos discos intervertebrais imediatamente craniais e caudais ao ponto acometido. Recentemente, a técnica de artroplastia com o uso da prótese Adamo Spinal Disc® foi proposta na Medicina Veterinária com o objetivo de preservar a mobilidade entre as vértebras e ao mesmo tempo manter a distração entre elas. Com o uso dessa prótese, os resultados clínicos foram favoráveis, porém a quantidade de distração e a mobilidade dos espaços intervertebrais reduziram-se com o passar do tempo, quando comparado com o pós-operatório imediato. Outra complicação encontrada foi o afundamento tardio do implante no corpo vertebral. O objetivo deste trabalho foi desenvolver uma prótese de disco intervertebral cervical por meio do design gráfico e avaliar de forma qualitativa e quantitativa as principais tensões no sistema prótese - corpo vertebral utilizando o método de elementos finitos (MEF). Para isso foram utilizadas dezesseis colunas cervicais (C3-C7) de cadáveres caninos maturos (25-35 Kg) que serviram como modelo e parâmetro para as mensurações do tamanho da prótese. A mensuração da largura, altura, comprimento e angulação das superfícies ventrais e placas terminais dos corpos vertebrais de C5-C6 das colunas cervicais coletadas foram realizadas a fim de se obter o tamanho médio da prótese a ser desenvolvida. A prótese foi desenvolvida no programa Rhinoceros® e utilizou-se prototipagem após impressão em 3D para definição do melhor design e mensurações do implante. A análise por meio do MEF foi realizada no programa AnsysWorkbench. Para comparar a prótese desenvolvida com a já existente no mercado, foram compostos dois grupos experimentais representados por: prótese de disco cervical constituída de liga de titânio, denominada PVTM Cervical Disc (grupo I - GI) e a prótese Adamo Spinal Disc® (grupo II - GII). As tensões nas superfícies dos corpos vertebrais e prótese (parte cranial P1; parte caudal P2 e parafusos) foram avaliadas após a aplicação de forças de extensão, flexão lateral e flexão ventral. As forças foram aplicadas com as vértebras posicionadas de duas formas: neutra (para ambos os grupos) e pré-posicionada (flexão e extensão máximas apenas para o GI). Com as vértebras posicionadas de forma neutra, tanto para o GI como para o GII, observou-se que as tensões totais médias geradas no corpo vertebral, em P1 e P2 foram respectivamente 51,7%, 72,7% e 57,1% maiores no GII do que em GI. Com as vértebras posicionadas de forma neutra para o GII e pré-posicionada para o GI, observou-se que as tensões totais médias geradas no corpo vertebral, em P1 e P2 foram respectivamente 119,9%, 123,6% e 105,4% maiores em GII que em GI. A prótese PVTM Cervical Disc (GI) apresentou design adequado e bom encaixe no espaço intervertebral entre C5 e C6, e as tensões totais médias geradas no osso e prótese foram maiores em GII quando comparado com o GI. O estudo permitiu desenvolver uma prótese com distribuição mais homogênea das tensões no corpo vertebral e que possivelmente evita o afundamento da mesma e consequente redução da distração e mobilidade intervertebral como ocorre com a prótese Adamo Spinal Disc® (GII) existente no mercado.


Cervical spondylomyelopathy (CSM) is a disease that usually affects various structures of the cervical spine of large and giant breed dogs causing compression of the spinal cord, nerve roots, or both. Surgery is the treatment of choice and different surgical techniques have been proposed for the treatment of CSM. In disk-associated disease a widely used treatment the better results is distraction-merger, however, this technique can lead to biomechanical changes in the adjacent segments increasing the risk of domino type injury with consequent degeneration of the discs immediately cranial and caudal to the affected point. Recently, arthroplasty was proposed in order to keep distraction and preservation of mobility at the affected site using the Adamo Spinal Disc® prosthesis. Clinical outcomes using this prosthesis were favorable but distraction and mobility in the treated intervertebral spaces were reduced in most dogs over time when compared to the immediate postoperative period. Sinking of the prosthesis in the vertebral body was the main complication. Therefore, the objective of this study was to develop a cervical intervertebral disc prosthesis and evaluate main stress points in the prosthesis system - vertebral body using the Finite Element Method (FEM). Sixteen cervical spine (C3-T1) of mature canine cadavers weighing between 25-35 Kg that served as a model and basis for the measurements of the size of the prosthesis were used. The measurement of width, height, length and angle of the ventral surfaces and end plates of the vertebral bodies of C5-C6 of the cervical spine collected were performed to obtain the average size of the prosthesis to be developed. The prosthesis has been developed in Rhinoceros program and used for 3D prototyping after printing to define the best "design" and measurements from the implant. Analysis by the FEM was held at AnsysWorkbench® program. We setup two experimental groups represented by: cervical disc prosthesis made of titanium alloy (group I - GI) and the prosthesis Adamo Spinal Disc® (group II - GII). The stresses in the surfaces of the vertebral bodies and implant (cranial plate - P1; flow plate - P2 and screws) were evaluated after applying extension forces, lateral bending and ventral flexing. The forces applied to the vertebrae were positioned in two ways: neutral (for both groups) and pre-positioned (maximum flexion and extension only for GI). Comparing tensions with the vertebrae positioned neutrally it was observed that the average total stress generated were 51.7%, 72.7% and 57.1% higher in GII than in GI, in the vertebral body, P1 and P2, respectively . Comparing the tensions in the neutral form (GII) and pre-positioned (GI), the average total stress generated were 119.9%, 123.6% and 105.4% higher in GII than GI, in the vertebral body, and P1 P2, respectively. The developed prosthesis PVTM Cervical Disc (GI) presented nice fit and proper "design" intervertebral space between C5 and C6 and the average total stress generated in the bone and prosthesis GII were higher when compared with the GI. The study allowed us to develop a prosthesis that features more homogeneous stress distribution in the vertebral body and prevents the sinking of the prosthesis and consequent reduction of distraction and intervertebral mobility as occurs in Spinal prosthesis Adamo Disc® (GII) on the market.

8.
Semina ciênc. agrar ; 31(2): 391-404, 2010.
Artigo em Português | LILACS-Express | VETINDEX | ID: biblio-1498594

Resumo

Water loss and sugar gain were modeling during the osmotic dehydration process of cylinders of apple. The transfer of solute to the fruit and the water to the solution was based on Ficks 2nd law generalized for simultaneous diffusion and solved by the finite element method using the software COMSOL Multiphysics 3.2. The main and cross diffusion coefficients, the relationship between the mass transfer and mass conductivity coefficients, as well, the Biot number were determined on the simulation with the implementation of the simplex optimization method through minimization of the percentage deviations. The value of deviation between the experimental and the simulated data were 5,76% for sucrose and 2,95 for water. The simulation despising the Biot number indicated that the resistance of the film can be disregarded in the phenomenon of mass transfer studied. The system developed to simulate solute and water diffusion will permit control and modulation of the sugar content in cylinder of apple.


A perda de água e o ganho de açúcar foram modelados durante o processo de desidratação osmótica de cilindros de maçã. A transferência de soluto para a fruta e de água para a solução,  foi modelada com base na 2ª Lei generalizada de Fick para difusão simultânea e resolvida por meio do método de elementos finitos utilizando o software COMSOL Multiphysics 3.2. Os coeficientes de difusão principais e cruzados, a relação entre o coeficiente de transferência de massa e o de condutividade mássica bem como o número de Biot foram determinados na simulação com a aplicação do método de otimização simplex por meio da minimização dos desvios percentuais. O valor dos desvios entre os dados experimentais e simulados foi de 5,76% para a sacarose e 2,95% para a água. A simulação, desprezando o número de Biot, indicou que a resistência externa pode ser desconsiderada no fenômeno de transferência de massa estudado. O sistema desenvolvido para simular a difusão da água e do soluto permitirá o controle e a modulação do conteúdo de açúcar nos cilindros de maçã.

9.
Semina Ci. agr. ; 31(2): 391-404, 2010.
Artigo em Português | VETINDEX | ID: vti-472372

Resumo

Water loss and sugar gain were modeling during the osmotic dehydration process of cylinders of apple. The transfer of solute to the fruit and the water to the solution was based on Ficks 2nd law generalized for simultaneous diffusion and solved by the finite element method using the software COMSOL Multiphysics 3.2. The main and cross diffusion coefficients, the relationship between the mass transfer and mass conductivity coefficients, as well, the Biot number were determined on the simulation with the implementation of the simplex optimization method through minimization of the percentage deviations. The value of deviation between the experimental and the simulated data were 5,76% for sucrose and 2,95 for water. The simulation despising the Biot number indicated that the resistance of the film can be disregarded in the phenomenon of mass transfer studied. The system developed to simulate solute and water diffusion will permit control and modulation of the sugar content in cylinder of apple.


A perda de água e o ganho de açúcar foram modelados durante o processo de desidratação osmótica de cilindros de maçã. A transferência de soluto para a fruta e de água para a solução,  foi modelada com base na 2ª Lei generalizada de Fick para difusão simultânea e resolvida por meio do método de elementos finitos utilizando o software COMSOL Multiphysics 3.2. Os coeficientes de difusão principais e cruzados, a relação entre o coeficiente de transferência de massa e o de condutividade mássica bem como o número de Biot foram determinados na simulação com a aplicação do método de otimização simplex por meio da minimização dos desvios percentuais. O valor dos desvios entre os dados experimentais e simulados foi de 5,76% para a sacarose e 2,95% para a água. A simulação, desprezando o número de Biot, indicou que a resistência externa pode ser desconsiderada no fenômeno de transferência de massa estudado. O sistema desenvolvido para simular a difusão da água e do soluto permitirá o controle e a modulação do conteúdo de açúcar nos cilindros de maçã.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA