Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 348
Filtrar
1.
Sci. agric ; 80: e20210260, 2023. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1390424

Resumo

Microbial contamination of the wort during the fermentation process causes significant losses in ethanol production worldwide and creates a dependence of the industry on chemicals and antibiotics to control contamination. Therefore, this study used electron beam (e-beam) to disinfect wort from sugarcane (Saccharum officinarum L.) molasses and investigate the bioethanol fermentation. Four treatments (T0 - T3) were carried out using ionizing doses of radiation through the electron accelerator: 0 (control), 10, 20, and 40 kGy. Total mesophiles, total bacteria, sucrose, glucose, fructose, phenolics, flavonoids, hydroxymethylfurfural (5-HMF), and Furfural were measured. An alcoholic fermentation assay was performed after the irradiation process. The irradiated treatments showed no inversion of sugars and formation of the inhibitory by-products flavonoids, furfural and 5-HMF, except for the phenolic compounds. The lower dose tested (10 kGy) reduced more than 99.9 % of the total mesophiles and more than 99.99 % of the total bacteria in the substrate. In the fermentation, the irradiated worts presented similar (p > 0.05) yields (92, 93, and 94 %) and ethanol productivity levels (0.89, 0.88, and 0.87 g L-1 h-1, for T1, T2, and T3 respectively). However, all treatments presented higher yields and productivity (p < 0.05) when compared to the control (88 % and 0.85 g L-1 h-1), highlighting the possible use of e-beam in wort fermentation at a lower dose (10 kGy). This allows reduction in losses caused by microbial contamination, besides increasing fermentation yield and productivity with lower energy consumption.(AU)


Assuntos
Bactérias , Etanol , Bioetanol , Antibacterianos , Fermentação
2.
Ciênc. Anim. (Impr.) ; 33(1): 145-151, jan.-mar. 2023. ilus
Artigo em Português | VETINDEX | ID: biblio-1434525

Resumo

A tungíase é uma infecção parasitária causada pela fêmea da pulga Tunga penetrans, que penetra na pele do hospedeiro para se alimentar e desenvolver seus ovos, gerando lesões que provocam prurido e dor. Assim, o objetivo deste trabalho foi relatar um caso de tungíase em um cão domiciliado em uma comunidade rural de Colinas, Maranhão. Em julho de 2020, um cachorro da raça American Pit Bull Terrier, com um ano e oito meses de idade, foi levado a uma clínica veterinária apresentando irritação e incômodo nas patas, o que dificultava sua locomoção. O cão vivia em uma residência com solo de chão batido, com acesso à rua e o tutor não possuía outros animais. Ao exame físico, constatou-se a presença de ectoparasitos nos coxins palmares e plantares, que foram retirados com auxílio de pinça cirúrgica e encaminhados ao Laboratório de Parasitologia da UFPI para identificação, confirmando tratar-se de pulgas da espécie Tunga penetrans. O cão recebeu tratamento à base de ivermectina 1%, 0,5mL via subcutânea, dose única, apresentando melhora no quadro clínico, e o tutor recebeu orientações sobre a desinfestação do ambiente. Conclui-se que a tungíase pode acometer cães em áreas rurais de um município do Maranhão, sendo importante o diagnóstico precoce e o tratamento adequado.


Tungiasis is a parasitic infection caused by the female flea Tunga penetrans, which penetrates the host's skin to feed and develop its eggs, generating lesions that provoke itching and pain. Thus, this study aimed to report a case of tungiasis in a dog domiciled in a rural community in Colinas, Maranhão. In july 2020, an American Pit Bull Terrier dog, one year and eight months old, was taken to a veterinary clinic with irritation and discomfort in the paws, which made it difficult to move. The dog lived in a house with beaten ground soil, had access to the street, and the tutor had no other animals. The physical examination showed the presence of ectoparasites on the palm and plantar pads, which were removed with surgical tweezers and sent to the UFPI Parasitology Laboratory for identification, confirming that they were Tunga penetrans fleas. The dog received a treatment based on ivermectin 1%, 0.5mL subcutaneously, single dose, showing improvement in the clinical picture, and the tutor received guidance on the disinfection of the environment. It is concluded that tungiasis can affect dogs in rural areas of a city in Maranhão, being important the early diagnosis and adequate treatment.


Assuntos
Animais , Cães , Doenças do Cão , Tunga/patogenicidade , Tungíase/veterinária , Zona Rural
3.
Rev. bras. zootec ; 52: e20210189, 2023. tab
Artigo em Inglês | VETINDEX | ID: biblio-1436778

Resumo

The objective of this study was to evaluate the effect of milking hygiene practices, herd size, water hardness, and temperature-humidity index (THI) on the physicochemical and microbiological characteristics of raw milk, and standard plate count (SPC) in milking machines of dairy farms in the central region of Mexico. Data were collected from fifty-three dairy farms during one year. The evaluated effects included milking hygiene conditions (good, medium, poor), herd size (1-50, 51-100, 101-150, ≥151 heads), water hardness (soft or moderately hard), and THI (comfortable or stressful). The increase in milking hygiene produced greater milk yield (MY) and energy corrected milk (ECM) but lower protein content, and decreased the individual bacterial count (IBC) and somatic cell count (SCC). The MY, ECM, protein content, IBC, and SCC were higher on bigger farms. The use of soft water reduced MY, IBC, and SCC, but improved fat, lactose, total solids (TS), and non-fat solids (NFS). Heat stress negatively affected fat, protein, TS, NFS, acidity, freezing point (FP), SCC, and methylene blue dye reduction test. Poor milking hygiene contributes to higher SPC in milking machine parts. Water hardness and THI did not affect SPC in all milking machine parts. Proper milking hygiene practices, larger herd size, softer water, lower THI, and adequate cleaning and disinfection of the milking machine parts benefits the physicochemical and microbiological quality of the milk.


Assuntos
Características da Água , Transtornos de Estresse por Calor , Leite , Fazendas
4.
Braz. j. biol ; 83: e273843, 2023.
Artigo em Inglês | VETINDEX | ID: biblio-1447642

Resumo

Instead of typical household trash, the heavy metal complexes, organic chemicals, and other poisons produced by huge enterprises threaten water systems across the world. In order to protect our drinking water from pollution, we must keep a close eye on the situation. Nanotechnology, specifically two-dimensional (2D) nanomaterials, is used in certain wastewater treatment systems. Graphene, g-C3N4, MoS2, and MXene are just a few examples of emerging 2D nanomaterials that exhibit an extraordinary ratio of surface (m3), providing material consumption, time consumption, and treatment technique for cleaning and observing water. In this post, we'll talk about the ways in which 2D nanomaterials may be tuned to perform certain functions, namely how they can be used for water management. The following is a quick overview of nanostructured materials and its possible use in water management: Also discussed in length are the applications of 2D nanomaterials in water purification, including pollutant adsorption, filtration, disinfection, and photocatalysis. Fluorescence sensors, colorimetric, electrochemical, and field-effect transistors are only some of the devices being studied for their potential use in monitoring water quality using 2D nanomaterials. Utilizing 2D content has its benefits and pitfalls when used to water management. New developments in this fast-expanding business will boost water treatment quality and accessibility in response to rising awareness of the need of clean, fresh water among future generations.


Em vez do lixo doméstico típico, os complexos de metais pesados, produtos químicos orgânicos e outros venenos produzidos por grandes empresas ameaçam os sistemas de água em todo o mundo. Para proteger nossa água potável da poluição, devemos ficar de olho na situação. A nanotecnologia, especificamente nanomateriais bidimensionais (2D), é usada em certos sistemas de tratamento de águas residuais. Grafeno, g-C3N4, MoS2 e MXene são apenas alguns exemplos de nanomateriais 2D emergentes que exibem uma extraordinária proporção de superfície (m3), proporcionando consumo de material, consumo de tempo e técnica de tratamento para limpeza e observação da água. Neste trabalho, trataremos das maneiras pelas quais os nanomateriais 2D podem ser ajustados para desempenhar determinadas funções, ou seja, como eles podem ser usados para o gerenciamento de água. A seguir, uma breve visão geral dos materiais nanoestruturados e seu possível uso no gerenciamento de água. Serão também discutidas detalhadamente as aplicações de nanomateriais 2D na purificação de água, incluindo adsorção de poluentes, filtração, desinfecção e fotocatálise. Sensores de fluorescência, colorimétricos, eletroquímicos e transistores de efeito de campo são apenas alguns dos dispositivos que estão sendo estudados para uso potencial no monitoramento da qualidade da água usando nanomateriais 2D. A utilização de conteúdo 2D tem seus benefícios e armadilhas quando utilizada para gerenciamento de água. Novos desenvolvimentos neste negócio em rápida expansão visam aumentar a qualidade e a acessibilidade do tratamento de água em resposta à crescente conscientização sobre a necessidade de água limpa e fresca entre as gerações futuras.


Assuntos
Poluição da Água/prevenção & controle , Monitoramento da Água , Purificação da Água , Nanoestruturas
5.
Hig. aliment ; 37(296): e1123, jan.-jun. 2023. graf, ilus, tab
Artigo em Português | VETINDEX | ID: biblio-1434269

Resumo

O amendoim (Arachis hypogaea L.) é uma oleaginosa com alto valor energético e nutricional, servindo de substrato ideal para o crescimento de fungos durante o processo de colheita, estocagem e processamento dos grãos. As micotoxinas são originadas a partir do metabolismo secundário de fungos toxigênicos; quando essas toxinas são ingeridas, podem causar efeitos tóxicos em humanos e animais. O objetivo deste trabalho foi avaliar a contaminação fúngica em amostras de grãos de amendoim disponíveis para o consumo humano. Foram analisadas amostras de amendoim torrado na vagem, amendoim cru (in natura) e amendoim torrado sem a vagem. A metodologia utilizada foi o método de plaqueamento direto em placas de Petri, contendo o meio cultura Sabouraud Dextrose Ágar (SDA). Porções de 40 grãos de amendoim de cada amostra foram utilizadas para o teste. Os resultados obtidos foram expressos em quantidade de grãos que apresentaram crescimento fúngico em porcentagem. Para identificação ao nível do género das colônias fúngicas isoladas, foi efetuada uma observação microscópica das suas estruturas morfológicas. Em todas as amostras estudadas ocorreram o crescimento de fungos potencialmente micotoxigênicos. Os grãos de amendoim cru (in natura) sem a vagem foram os mais contaminados por fungos como Aspergillus sp. (20%), Alternaria sp. (13,1%), Penicillium sp. (13,3%) e Fusarium sp. (23,3%) quando comparados com os grãos torrados. A presença desses fungos nas amostras de amendoim indica a possibilidade de desenvolvimento de micotoxinas potencialmente tóxicas para o humano. O processo de torrefação inibe o crescimento de determinadas espécies de fungos micotoxigênicos.(AU)


Peanut is an oilseed with high energy and nutritional value, serving as an ideal substrate for the growth of fungi during the process of harvesting, storing and processing the grains. Mycotoxins originate from the secondary metabolism of toxigenic fungi; when ingested, they can cause toxic effects in humans and animals. The objective of this work was to evaluate the fungal contamination in samples of peanut grains available for human consumption. The methodology used was the direct plating method in Petri dishes containing Sabouraud Dextrose Agar (SDA) culture. Portions of 40 peanut kernels from the samples were immersed in a 0.4% sodium hypochlorite solution for two minutes for surface disinfection, then rinsed once in distilled water. Incubation was carried out at room temperature for 7 days and the results were expressed as the amount of grains that showed fungal growth in percentage. To identify the colonies of isolated filamentous fungi at the genus level, a microscopic observation of their morphological structures was carried out, which consists of removing a sample from the edge of the colony and placing it in a drop of cotton blue (1g/L in lactic acid 88%), between slide and coverslip. Potentially toxigenic fungi were identified: Aspergillus sp., Rhizopus sp., Alternaria sp., Penicillium sp. and Fusarium sp. The presence of these fungi in peanut samples indicates the possibility of development of mycotoxins potentially toxic to humans. The roasting process may not be sufficient to destroy some mycotoxins.(AU)


Assuntos
Arachis/microbiologia , Fungos/crescimento & desenvolvimento , Micotoxinas/metabolismo , Aflatoxinas/análise
6.
Rev. bras. ciênc. avic ; 25(3): eRBCA-2022-1758, 2023. graf, tab
Artigo em Inglês | VETINDEX | ID: biblio-1451859

Resumo

This study aims to identify relative proportions of beneficial and pathogenic bacteria in the gut of broilers and risk factors that may be contributing to the development of colibacillosis disease in broiler farms of District Kasur, Punjab, Pakistan. For this, 10 healthy and 10 colibacillosis affected broiler farms were surveyed for ileum and blood sample collection along with data regarding farm management, antibiotic use and hygiene practices. Lactobacillus and Escherichia coli number was estimated using Miles and Misra method and colibacillosis was confirmed by Congo red dye assay. Lactobacillus and E. coli were identified biochemically. For risk factors analysis chi-square analysis was performed to find any significant association between the health status of the farm and risk factors. Results showed during disease and healthy conditions Lactobacillus and Escherichia coli counts differ significantly (p<0.05). E. coli counts (106-108 to 107-109) increased (p<0.05) about three folds and Lactobacillus counts decrease (106-108 to 105-107) about four folds in disease conditions. Risk factor analysis showed colibacillosis disease was significantly associated (p<0.05) with non-vaccinated flocks, natural ventilation systems, rodent presence and the lack of outfit disinfection or change by workers when moving between different houses. It is concluded that E. coli and Lactobacillus work antagonistically to each other. However, further research is necessary to determine the exact mechanisms by which E. coli and Lactobacillus influence the development of colibacillosis. While Lactobacillus as probiotic may help with prevention, good hygiene and management practices are still crucial in preventing the spread of disease.(AU)


Assuntos
Animais , Galinhas/microbiologia , Escherichia coli/patogenicidade , Infecções por Escherichia coli/diagnóstico , Lactobacillus/patogenicidade , Paquistão , Fatores de Risco
7.
Pesqui. vet. bras ; 42: e06990, 2022. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1365240

Resumo

The current techniques used in the disinfection of reused poultry litter, such as lime addition, windrowing and plastic cover on the surface, do not guarantee the elimination of pathogenic microorganisms, causing damage to the environment and animal health. Gram negative bacteria, i.e., Salmonella and Escherichia coli, can be transmitted from one batch to another through reused litter, causing health damage to broilers and humans that consume food contaminated by these agents. Our study assessed the effectiveness of the methods plastic cover on the surface (PCS) and plastic cover on the surface with ammonia gas injection (PCSAI) in the control of Gram negative bacteria. The results obtained, both in laboratory conditions (Experiment 1) and in the field (Experiment 2), demonstrate that the method PCSAI with 0.22% ammonia gas had a significant reduction (P<0.05) of Gram negative bacteria in the period of 48 hours This new methodology for disinfecting poultry litter will allow its reuse in a practical and safe way, improving the preservation of the environment, of the health of broilers and consumers of poultry products.


O reaproveitamento de camas aviárias na criação de frangos de corte é uma prática muito utilizada no Brasil. Essa prática reduz custos de produção e contribui na conservação do meio ambiente. As técnicas atuais utilizadas na desinfecção de camas aviárias reaproveitadas, como adição de cal, enleiramento e lona na superfície, não garantem a eliminação de microrganismos patogênicos porque não geram quantidade suficiente de amônia. O gás amônia, em concentrações elevadas, tem efeito biocida. Bactérias Gram negativas, como as Salmonelas e Escherichia coli, podem ser transmitidas de um lote para outro através do reaproveitamento da cama, ocasionando prejuízos para a saúde das aves e dos humanos que consomem alimentos contaminados por estes agentes. Este trabalho avaliou a eficácia do método lona na superfície com injeção de gás amônia no controle de microrganismos Gram negativos. Os resultados obtidos demostraram que esse método controlou os microrganismos Gram negativos num período de 48 horas em camas de frangos de corte reaproveitadas. Assim, essa nova metodologia de desinfecção de camas de aviário permitirá sua reutilização de forma prática e segura, melhorando a saúde das aves e dos consumidores dos produtos avícolas.


Assuntos
Animais , Aves Domésticas/microbiologia , Galinhas , Desinfecção/métodos , Amônia/uso terapêutico , Bactérias Gram-Negativas
8.
Arq. Inst. Biol. (Online) ; 89: e00022021, 2022. tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1416873

Resumo

Biosecurity, cleaning and disinfection of swine and poultry facilities are fundamental for the reduction of pathogenic microorganisms of importance for public and animal health. The objective of this work was to compare the levels of active ingredient described on the label and the real levels detected in high-performance liquid chromatography (HPLC) of two disinfectants., then evaluate the antimicrobial activity since, following the Germicidal Sanitizing Action and Disinfectant Detergent (Official Method AOAC 960.09) in four different dilutions with the presence of 3% organic matter during 15 min of contact, against Salmonella Heidelberg and Salmonella Typhimurium (ST). The product "A" presents active levels of agreement according to the label. The content of quantified assets for product "B" was lower than that recorded on the label. The disinfectant "A" was effective in microbiological evaluation while the disinfectant "B" had microbiocidal activity compromised by the deficit of assets.


Assuntos
Salmonella , Salmonella typhimurium , Compostos de Benzalcônio/administração & dosagem , Desinfecção/métodos , Glutaral/administração & dosagem , Desinfetantes/análise , Cromatografia Líquida de Alta Pressão
9.
Pesqui. vet. bras ; 42: e06987, 2022. tab
Artigo em Inglês | VETINDEX | ID: biblio-1436968

Resumo

The aim of this study was to access the efficacy of four disinfectants to inactivate influenza A [H1N1] 0 hour and 72 hours after disinfectant dilution. A pandemic H1N1 influenza virus isolated from a pig with respiratory disease was used to obtain inoculums containing 6.4log10 EID50/mL; 5.4log10 EID50/mL; 4.4log10 EID50/mL and 3.4log10 EID50/mL. Suspension test was composed of 400µL of viral inoculum, 100µL of organic load and 500µL of each individually diluted disinfectant and incubated for ten minutes of contact time. After a neutralizing step, each mixture was filtered on a 0.22µm membrane and 0.2mL was inoculated in six 9-day-old embryo chicken egg through allantoic route. The allantoic fluid from eggs was harvest for RT-PCR and hemagglutination test. The experiment was repeated 72 hours after disinfectant dilution. On the first assessment with fresh disinfectant, influenza virus was inactivated by oxidizing compost disinfectant and phenolic disinfectant in all virus concentrations, the quaternary ammonium compound (QAC) and glutaraldehyde association inactivated the virus up to a concentration of 5.4log10 EID50/mL. QAC disinfectant did not eliminate virus viability. Seventy-two hours after disinfectants were diluted, oxidizing compost disinfectant and QAC and glutaraldehyde association disinfectant demonstrated the same result as the evaluation with fresh disinfectant solution. Phenolic disinfectant inactivated viral inoculum up to a concentration of 5.4log10 EID50/mL. QAC had no effect on inactivating 3.4log10 EID50/ mL of influenza virus. In conclusion, three of the four disinfectants tested were effective to inactivate pandemic H1N1 influenza virus in the presence of organic load. Test result performed 72hours after disinfectant dilution suggest a decrease in the effectiveness of one disinfectant.


O objetivo deste trabalho foi avaliar a eficácia de quatro desinfetantes em inativar o vírus da influenza A [H1N1] 0-hora e 72-horas após a diluição dos produtos. Um vírus H1N1 pandêmico isolado previamente de um suíno com doença respiratória foi utilizado e foram obtidas quatro concentrações de inóculo contendo 6,4log10 EID50/mL; 5,4log10 EID50/mL; 4,4log10 EID50/mL and 3,4log10 EID50/mL. Para compor o teste em suspensão foram adicionados 400µL de inóculo viral, 100µL de matéria orgânica e 500µL de cada desinfetante diluído individualmente e a mesma foi incubada por 10 minutos. Após a etapa neutralizante, a suspensão foi filtrada em membrana 0,22µm e 0,2mL foi inoculado em seis ovos de galinha embrionados de nove dias de incubação, via rota alantóide. O fluido alantóide foi colhido após 72 horas para testes de hemaglutinação e RTPCR. O mesmo protocolo experimental foi repetido usando as soluções desinfetantes 72 horas após a diluição. O vírus da influenza foi inativado pelo composto oxidante e também pelo desinfetante fenólico em todas as concentrações virais testadas 0-hora após diluição. O desinfetante com associação de amônia quaternária e glutaraldeído inativou o vírus na concentração de até 5,4log10 EID50/mL. O desinfetante à base de amônia quaternária não inativou o vírus. Os resultados 72-horas após a diluição não diferiram quando comparado com 0-hora, exceto o desinfetante fenólico, o qual inativou o vírus da influenza somente até a concentração 5,4log10 EID50/ mL. Concluindo, três dos quatro desinfetantes testados foram efetivos ao inativar o vírus da influenza [H1N1] pandêmico na presença de matéria orgânica. Os resultados do teste com produtos diluídos após 72 horas sugerem redução da efetividade em, pelo menos, um desinfetante.


Assuntos
Animais , Suínos/virologia , Desinfecção/métodos , Desinfetantes/análise , Vírus da Influenza A Subtipo H1N1 , Matéria Orgânica , Reação em Cadeia da Polimerase em Tempo Real/veterinária
10.
Braz. j. biol ; 822022.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1468606

Resumo

Abstract High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Resumo Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.

11.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1487698

Resumo

ABSTRACT: The current techniques used in the disinfection of reused poultry litter, such as lime addition, windrowing and plastic cover on the surface, do not guarantee the elimination of pathogenic microorganisms, causing damage to the environment and animal health. Gram negative bacteria, i.e., Salmonella and Escherichia coli, can be transmitted from one batch to another through reused litter, causing health damage to broilers and humans that consume food contaminated by these agents. Our study assessed the effectiveness of the methods plastic cover on the surface (PCS) and plastic cover on the surface with ammonia gas injection (PCSAI) in the control of Gram negative bacteria. The results obtained, both in laboratory conditions (Experiment 1) and in the field (Experiment 2), demonstrate that the method PCSAI with 0.22% ammonia gas had a significant reduction (P 0.05) of Gram negative bacteria in the period of 48 hours This new methodology for disinfecting poultry litter will allow its reuse in a practical and safe way, improving the preservation of the environment, of the health of broilers and consumers of poultry products.


RESUMO: O reaproveitamento de camas aviárias na criação de frangos de corte é uma prática muito utilizada no Brasil. Essa prática reduz custos de produção e contribui na conservação do meio ambiente. As técnicas atuais utilizadas na desinfecção de camas aviárias reaproveitadas, como adição de cal, enleiramento e lona na superfície, não garantem a eliminação de microrganismos patogênicos porque não geram quantidade suficiente de amônia. O gás amônia, em concentrações elevadas, tem efeito biocida. Bactérias Gram negativas, como as Salmonelas e Escherichia coli, podem ser transmitidas de um lote para outro através do reaproveitamento da cama, ocasionando prejuízos para a saúde das aves e dos humanos que consomem alimentos contaminados por estes agentes. Este trabalho avaliou a eficácia do método lona na superfície com injeção de gás amônia no controle de microrganismos Gram negativos. Os resultados obtidos demostraram que esse método controlou os microrganismos Gram negativos num período de 48 horas em camas de frangos de corte reaproveitadas. Assim, essa nova metodologia de desinfecção de camas de aviário permitirá sua reutilização de forma prática e segura, melhorando a saúde das aves e dos consumidores dos produtos avícolas.

12.
Arq. Inst. Biol. (Online) ; 89: e00272021, 2022. tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1416817

Resumo

Petri disease is a problem for vineyard caused mainly by the fungus Phaeomoniella chlamydospora. Contaminated seedlings are source of inoculum for the disease. Treatment to disinfect vine rootstock cuttings for seedling production is hot water treatment (HWT) by 50 °C for 30 min, but the efficiency is contested. To improve its efficacy, the study aimed to assess the combination of the following methods and the reason for the control: i) exposition of the fungus to five different temperatures in HWT bath for 30 min; ii and iii) exposition of the fungus and also plants infected with P. chlamydospora to different disinfection treatments (biofumigation = soil + cabbage at 40 °C; temperatures of 40 and 23 °C, all in microcosm), in different periods (7, 14 and 21 days), with and without additional HWT (51 °C for 30 min). The results showed that HWT with high temperatures (55­70 °C) for 30 min inactivated the fungus. Biofumigation technique at 40 °C and the temperature solely of 40 °C applied for up to 21 days and combined with HWT (51 °C for 30 min) inhibited mycelial growth and inactivated the fungus in vine plant tissues without compromising the rooting.


Assuntos
Ascomicetos , Vitis/microbiologia , Fungicidas Industriais/uso terapêutico , Microbiologia do Solo
13.
Braz. j. biol ; 82: e234471, 2022. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1153460

Resumo

High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.


Assuntos
Esgotos , Bactérias/genética , Fenótipo , Brasil , Testes de Sensibilidade Microbiana , Centros de Atenção Terciária
14.
Braz. j. biol ; 82: 1-6, 2022. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1468419

Resumo

High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.


Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.


Assuntos
Enterococcus/patogenicidade , Esgotos/análise , Microbiologia da Água/normas , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/toxicidade , Resistência Microbiana a Medicamentos , Staphylococcus aureus/patogenicidade
15.
Acta sci. vet. (Impr.) ; 50(supl.1): 781, 2022. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1370150

Resumo

Background: Haw's syndrome results in bilateral projection of the third eyelid, which is caused by a dysfunction of the sympathetic innervation in the region, not accompanied by other ocular changes. It has been mostly seen in cats, under 2-year-old and, it usually shows an acute presentation. It is believed that the disorder may be self-limiting, but several infectious etiologies have been proposed, together with diarrhea. The aim of the study was to report a case of a 2-year-old mixed breed male feline, castrated and diagnosed with Haw's syndrome, associated with an infectious condition given the presence of Giardia sp. Case: A 2-year-old male, mixed-breed cat and orchiectomized, was admitted and treated at the Veterinary Hospital of the Federal University of Jataí. In the anamnesis, the owner complained that the cat had had pasty brown diarrhea for 4 days and a projection of the third eyelid. He emphasized that the animal used to have some episodes of diarrhea sporadically and the last deworming was carried out 3 months ago from that day. He reported contact with other random street and outdoor cats. On the physical examination, bilateral projection of the third eyelid was observed without any other visible alteration. The third eyelid projection was responsive to the mydriatic and adrenergic [phenylephrine 10%] eye drops instillation test. Complete blood count and serum biochemical evaluation of creatinine, alkaline phosphatase (ALP) and alanine aminotransferase (ALT) concentrations were performed. In addition, abdominal ultrasound and parasitological examination of feces were requested. Complete blood count showed eosinophilia and serum biochemical evaluations were within reference values. The coproparasitological examination detected Giardia sp. On the ultrasound, no significant changes were observed. The recommended treatment was anthelmintic [fenbendazole 50 mg/kg, SID, for 5 days]. However, one week later, the coproparasitological examination still showed Giardia sp. Given this scenario, the chosen treatment was the use of nitazoxanide [25 mg/kg, BID, for 7 days]. Therefore, the patient presented emesis and the treatment with nitazoxanide had to be suspended. Thus, metronidazole [25 mg/kg, BID, for 7 days] was prescribed, in addition to the environmental disinfection and daily litter box cleaning, all performed with quaternary ammonia. After 1 week of treatment with metronidazole, the patient's clinical improvement and reversal of the third eyelid projection were observed. Discussion: This case proved to be consistent with the data found in the literature, in which cats younger than 2-year-old are affected by Haw's syndrome and may present concomitant diarrhea. On the physical examination, the parameters evaluated were within normal reference for the cat species and the bilateral projection of the third eyelid was the only alteration found in the patient. The prognosis for the patient with Haw's syndrome and concomitant giardiasis is favorable, as long as the intestinal infection is treated briefly, in order to prevent the chronicity of the enteroparasitosis. The need of more studies is evident in order to explain the Haw's syndrome pathology and so, clarify the real cause of this disease. Since the syndrome is mostly, a self-limiting disease, interventions with topical ocular drugs are not necessary. However, in the event of a concomitant disease, infection or underlying cause, it must be treated correctly. Attention is drawn to the need of feces examination through coproparasitological evaluation in cases of diarrhea.


Assuntos
Animais , Masculino , Gatos , Giardíase/veterinária , Disenteria/veterinária , Enteropatias Parasitárias/veterinária , Membrana Nictitante/patologia
16.
Arq. bras. med. vet. zootec. (Online) ; 74(1): 117-125, Jan.-Feb. 2022. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1374403

Resumo

This study identified the risk factors associated with parasite infestation in tambaqui fingerlings Colossoma macropomum from São Francisco region SE/AL. The fingerlings fish farms were and characterized about water quality, handling, feeding management and sanitary aspects. Parasitological indexes (prevalence, mean intensity and abundance) were obtained from 380 fish and correlated to the aspects of fish farms as well as biotic and abiotic factors to determine the risk factors. The fish rearing in earthen ponds increased the parasite infestations in tambaqui fingerlings, and the mainly parasites founded were monogenean, Myxobolus sp., Ichthyophthirius multifiliis and digenean metacercaria. The main risk factors identified were associated to irregular water supply and consequently low water quality (total ammonia); lack of biometric procedure which promoted an inadequate feeding rate; and absence of disinfection of tools and ponds. Thus, improvements on these specific aspects in fish farms from São Francisco region must be carried out to avoid disease outbreaks, dissemination, mortalities and economic losses.


Este estudo identificou os fatores de risco associados à ocorrência de parasitas em alevinos de tambaqui Colossoma macropomum da região do baixo São Francisco, SE/AL. As pisciculturas foram caracterizadas segundo parâmetros de qualidade da água, manejo, alimentação e dos aspectos sanitários. Os índices parasitológicos (prevalência, intensidade média e abundância) foram obtidos mediante a análise de 380 peixes e correlacionados com as características das pisciculturas, bem como com os fatores bióticos e abióticos, a fim de determinar os fatores de risco. A fase de crescimento dos alevinos realizada em tanques de terra aumentou as infestações de parasitas, e os principais parasitas encontrados foram monogenéticos, Myxobolus sp., Ichthyophthirius multifiliis e metacercária de digenético. Os principais fatores de risco identificados foram: abastecimento irregular de água e consequente baixa qualidade da água (amônia total); falta de procedimento biométrico, que promoveu uma taxa de alimentação inadequada; e ausência de desinfecção dos tanques e das ferramentas. Pelo exposto, melhorias, especificamente nesses aspectos, nas pisciculturas de alevinos da região do São Francisco, devem ser realizadas para evitar surtos e disseminação de doenças, assim como mortalidades e perdas econômicas.


Assuntos
Animais , Doenças Parasitárias em Animais/prevenção & controle , Doenças Parasitárias em Animais/epidemiologia , Caraciformes/parasitologia , Infecções por Mesomycetozoea , Myxobolus , Metacercárias , Pesqueiros
17.
Braz. J. Biol. ; 82: 1-6, 2022. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-32994

Resumo

High doses of antibiotics used in hospitals can affect the microbial composition of sewers, selecting resistant bacteria. In this sense, we evaluated the antibiotic resistance profile and the multiresistant phenotype of bacteria isolated in sewage from a tertiary hospital in the interior São Paulo state, Brazil. For bacteria isolation, 10 µL of sewage samples were sown in selective culture media and the isolates were identified using VITEK-2 automatized system. The antibiotic sensitivity test was performed by disk diffusion. High percentages of resistance were found for amoxicillin, ampicillin, ceftazidime, clindamycin, vancomycin and the multidrug-resistant phenotype (MDR) was attributed to 60.7% of the isolates. Our results show bacteria classified as critical/high priority by WHO List of Priority Pathogens (Enterococcus and Staphylococcus aureus resistant to vancomycin and Enterobacteriaceae resistant to carbapenems) in hospital sewage. Therefore, the implementation of disinfection technologies for hospital sewage would reduce the bacterial load in the sewage that will reach urban wastewater treatment plants, minimizing superficial water contamination and bacterial resistance spread in the environment.(AU)


Altas doses de antibióticos utilizados em hospitais podem afetar a composição microbiana dos esgotos, selecionando bactérias resistentes. Nesse sentido, avaliamos o perfil de resistência a antibióticos e o fenótipo multirresistente de bactérias isoladas em esgoto de um hospital terciário no interior do estado de São Paulo, Brasil. Para o isolamento de bactérias, foram semeados 10 µL das amostras de esgoto em meios de cultura seletivos e os isolados foram identificados usando o sistema automatizado VITEK-2. O teste de sensibilidade aos antibióticos foi realizado por disco-difusão em ágar. Elevadas porcentagens de resistência foram encontradas para amoxicilina, ampicilina, ceftazidima, clindamicina, vancomicina e o fenótipo multirresistente (MDR) foi atribuído a 60,7% dos isolados. Nossos resultados mostram bactérias classificadas como prioridade crítica/alta pela Lista de Patógenos Prioritários da OMS (Enterococcus e Staphylococcus aureus resistentes à vancomicina e Enterobacteriaceae resistentes aos carbapenêmicos) no esgoto hospitalar. Sendo assim, implementação de tecnologias de desinfecção do esgoto hospitalar reduziriam a carga bacteriana no esgoto que chegará às estações de tratamento de esgoto urbanas, minimizando a contaminação dos ecossistemas hídricos receptores e a disseminação da resistência bacteriana no ambiente.(AU)


Assuntos
Poluentes Químicos da Água/análise , Poluentes Químicos da Água/toxicidade , Esgotos/análise , Resistência Microbiana a Medicamentos , Microbiologia da Água/normas , Enterococcus/patogenicidade , Staphylococcus aureus/patogenicidade
18.
Arq. bras. med. vet. zootec. (Online) ; 73(5): 1137-1146, Sept.-Oct. 2021. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1345273

Resumo

This study aimed to evaluate the effectiveness of ultraviolet light in reducing bacterial load of eggshells and the impact of experimental disinfection on hatching, embryo mortality, and time-borne distribution using broiler breeder hens of different ages (38, 42, and 48 weeks old). Fertile eggs were subjected to different exposure periods (5, 7, and 9 minutes) of UV light (UV-C) with a 254 nm wavelength. For controls, eggs disinfected with paraformaldehyde (5.3 g/m3) and eggs not disinfected (NC). After subjection to disinfection protocols, the eggs were placed into sterile plastic bags containing 20 mL of peptone saline solution (0.1% m:v) and massaged for 1 minute to release the bacterial load. Aliquots of this solution were incubated in specific medium for bacterial growth for 48 hours at 37ºC for subsequent CFU counts. To evaluate the effects of disinfection on production, eggs previously disinfected by UV-C (9 min) and paraformaldehyde and NC eggs were candled between incubation days 10 and 13 and at the end of the incubation period to assess embryonic mortality. Hatchability distribution was performed every 8 hours. The 9 minutes 254nm UV-C light exposure was able to disinfect viable eggs and matched the effectiveness of the paraformaldehyde technique.(AU)


Objetivou-se avaliar a eficácia da luz ultravioleta na redução da carga bacteriana de cascas de ovos e o impacto na eclosão e na mortalidade embrionária observando-se a idade das matrizes (38, 42 e 48 semanas). Os ovos foram submetidos a diferentes períodos de exposição (cinco, sete e nove minutos) à luz UV (UV-C) com comprimento de onda de 254nm. Os controles foram ovos desinfetados com paraformaldeído (5,3g/m³) e ovos não desinfetados (NC). Após a desinfecção, os ovos foram colocados em sacos plásticos estéreis contendo 20mL de solução salina peptonada (0,1% m:v) e massageados por um (1) minuto para descolamento das bactérias. Alíquotas dessa solução foram incubadas em meio para crescimento bacteriano por 48 horas a 37ºC e contagem de UFC. Para avaliar os efeitos da desinfecção, ovos previamente desinfetados por UV-C (nove minutos) e ovos com paraformaldeído e NC foram submetidos à ovoscopia entre os dias 10 e 13 de incubação e ao final do período de incubação, para avaliação da mortalidade embrionária. A distribuição da eclodibilidade foi realizada a cada oito horas. A exposição à luz UV-C de 25nm de nove minutos desinfetou os ovos férteis e coincidiu com a eficácia do paraformaldeído.(AU)


Assuntos
Animais , Galinhas , Desinfecção/métodos , Ovos/efeitos da radiação , Ovos/microbiologia , Raios Ultravioleta
19.
Acta sci. vet. (Impr.) ; 49: Pub.1800-2021. tab
Artigo em Inglês | VETINDEX | ID: biblio-1458439

Resumo

Background: This study aimed to assess the level of bacterial contamination in the Small Animals Sector of the VeterinaryMedical Teaching Hospital (HCV) of the Universidade Federal do Rio Grande do Sul (UFRGS). Firstly, a committee wasinvited to complete a questionnaire and to list critical sample sites for collection. With the identification of the places to besampled, collections were made with sterile swabs on different surfaces of environments of the HCV. The identification ofimportant bacteria in the veterinary area, in the different sampled environments, raises the concern for hygiene proceduresin the veterinary hospital environment.Materials, Methods & Results: Sixteen samples were collected from these different areas, and microbiological analyses wereperformed. Standard counts of viable and strictly aerobic mesophilic microorganisms were realized. Collections were madeto assess ambient air quality. With the microbiological analysis performed, bacteria of clinical importance were identified.To assess the resistance profile of the bacteria, the susceptibility test to antimicrobials was performed. MALDI-TOF/MSmeasurement identified 29 bacteria at the genus level and 10 bacteria at the species level and the antimicrobial susceptibility test was realized. Most of the isolates identified (60%) were bacteria of the genus Staphylococcus spp. Regardingantimicrobial susceptibility analysis the 10 bacteria identified at the species level were assessed. Test results showed thatthe isolates S. aureus, S. epidermidis and S. haemolyticus - collected from treatment room 2 - and S. haemolyticus, whichhad been isolated from samples from treatment room 2 of the cattery, presented multiresistance. Pantoea ananatis isolatesfrom room 5 also showed a multiresistant profile for erythromycin, cephalothin, vancomycin and ampicillin. Micrococcusluteus isolates from the x-ray room and the kennel showed resistance to ceftazidime. Staphylococcus equorum isolates...


Assuntos
Animais , Contaminação Biológica/análise , Hospitais Veterinários , Indicadores de Contaminação , Poluição do Ar , Contaminação de Equipamentos , Desinfecção das Mãos , Farmacorresistência Bacteriana Múltipla , Resistência Microbiana a Medicamentos
20.
Acta sci. vet. (Online) ; 49: Pub. 1800, Apr. 11, 2021. tab
Artigo em Inglês | VETINDEX | ID: vti-762302

Resumo

Background: This study aimed to assess the level of bacterial contamination in the Small Animals Sector of the VeterinaryMedical Teaching Hospital (HCV) of the Universidade Federal do Rio Grande do Sul (UFRGS). Firstly, a committee wasinvited to complete a questionnaire and to list critical sample sites for collection. With the identification of the places to besampled, collections were made with sterile swabs on different surfaces of environments of the HCV. The identification ofimportant bacteria in the veterinary area, in the different sampled environments, raises the concern for hygiene proceduresin the veterinary hospital environment.Materials, Methods & Results: Sixteen samples were collected from these different areas, and microbiological analyses wereperformed. Standard counts of viable and strictly aerobic mesophilic microorganisms were realized. Collections were madeto assess ambient air quality. With the microbiological analysis performed, bacteria of clinical importance were identified.To assess the resistance profile of the bacteria, the susceptibility test to antimicrobials was performed. MALDI-TOF/MSmeasurement identified 29 bacteria at the genus level and 10 bacteria at the species level and the antimicrobial susceptibility test was realized. Most of the isolates identified (60%) were bacteria of the genus Staphylococcus spp. Regardingantimicrobial susceptibility analysis the 10 bacteria identified at the species level were assessed. Test results showed thatthe isolates S. aureus, S. epidermidis and S. haemolyticus - collected from treatment room 2 - and S. haemolyticus, whichhad been isolated from samples from treatment room 2 of the cattery, presented multiresistance. Pantoea ananatis isolatesfrom room 5 also showed a multiresistant profile for erythromycin, cephalothin, vancomycin and ampicillin. Micrococcusluteus isolates from the x-ray room and the kennel showed resistance to ceftazidime. Staphylococcus equorum isolates...(AU)


Assuntos
Animais , Indicadores de Contaminação , Poluição do Ar , Contaminação Biológica/análise , Hospitais Veterinários , Resistência Microbiana a Medicamentos , Farmacorresistência Bacteriana Múltipla , Contaminação de Equipamentos , Desinfecção das Mãos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA