Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec. (Online) ; 75(1): 98-106, 2023. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1416594

Resumo

Atrial septal aneurysm (ASA) is a rare congenital deformity of variable clinical relevance, often reported in association with patent foramen ovale (PFO). Transthoracic Doppler echocardiography (TTE) is the first choice for diagnosis, but complementary techniques, such as microbubble contrast, should be used. Despite its importance, in Veterinary Medicine, there is little information related to the subject, and the present study is the second report of this condition in dogs. The objective was to report a case of ASA type IV LR associated with PFO in a Shar Pei bitch, diagnosed by a combined approach of transthoracic echocardiography backed by agitated saline solution (microbubbles). During clinical care, the owners reported episodes of seizures as their main complaint. Echocardiographic examination revealed a type 4 LR atrial septal aneurysm and left ventricular systolic dysfunction. The use of microbubble contrast showed right-to-left shunt, confirming PFO. The recommended treatment was medication. It was concluded that the rarity of ASA in dogs may be due to incomplete diagnoses and the transthoracic echocardiographic examination allows its analysis and classification. Furthermore, ASA can be found in animals with or without evidence of heart disease and it should be investigated in patients with neurological alterations.


O aneurisma do septo atrial (ASA) é uma rara deformidade congênita, de relevância clínica variável, frequentemente relatado em associação a forame oval patente (PFO). O ecodopplercardiograma transtorácico (TTE) é a primeira escolha para o diagnóstico, mas técnicas complementares, como o contraste por microbolhas, devem ser utilizadas. Apesar da importância, em medicina veterinária existe uma carência de informações relacionadas ao tema, sendo esse o segundo relato dessa condição em cão. Objetivou-se relatar um caso de ASA tipo IV LR, associado a PFO, em uma cadela Shar Pei, diagnosticado por uma abordagem combinada por ecodopplercardiograma transtorácico e costrastado com solução salina agitada (microbolhas). Ao atendimento clínico, os proprietários relataram, como queixa principal, episódios de crises convulsivas. O exame ecocardiográfico revelou aneurisma de septo atrial tipo 4 LR e disfunção sistólica em ventriculo esquerdo. A utilização de contraste por microbolhas constatou shunt direita-esquerda, confirmando PFO. O tratamento recomendado foi medicamentoso. Concluiu-se que a raridade do ASA em cães pode ser devido a diagnósticos incompletos, e o exame ecocardiográfico transtorácico permite sua análise e classificação. Ainda, ASA pode ser encontrado em animais com ou sem evidências de cardiopatia e sua investigação deve ser feita em pacientes com alterações neurológicas.


Assuntos
Animais , Feminino , Cães , Forame Oval Patente/veterinária , Aneurisma Cardíaco/veterinária , Cardiopatias Congênitas/veterinária , Comunicação Interatrial/veterinária , Ecocardiografia/veterinária
2.
Rev. bras. reprod. anim ; 46(1): 17-27, Janeiro-Março 2022. tab
Artigo em Português | VETINDEX | ID: biblio-1378025

Resumo

O objetivo desta revisão foi descrever as principais técnicas de avaliação e achados ultrassonográficos da próstata canina. A ultrassonografia é o método de escolha para avaliação da glândula prostática, sendo imprescindível como auxílio no diagnóstico na detecção de anormalidades, principalmente quando há suspeita da presença de tumores. Com inovação dos equipamentos, surgiram técnicas complementares à ultrassonografia modo Bidimensional (B), tais como Doppler, ultrassonografia contrastada e elastografia, que aumentam a acurácia diagnóstica. O Doppler fornece informações sobre arquitetura vascular e aspectos hemodinâmicos dos vasos sanguíneos. A ultrassonografia contrastada permite determinar parâmetros relacionados à perfusão sanguínea das estruturas pelos agentes de contraste (ex.: microbolhas), definindo, portanto, padrões de alta e baixa intensidade da arquitetura vascular. A elastografia proporciona a avaliação da rigidez tecidual tanto de forma qualitativa, por meio de elastogramas, quanto quantitativa, por meio das velocidades de cisalhamento. Espera-se que esta revisão possa contribuir com informações relevantes aos leitores e veterinários da área de ultrassonografia e reprodução animal.(AU)


The purpose of this review was to describe the main assessment techniques and ultrasound findings of the canine prostate. Ultrasonography is the method of choice for assessing the prostate gland, being essential as an aid in the diagnosis in the detection of abnormalities, especially when the presence of tumors is suspected. With the innovation of the equipment, complementary techniques to B-mode ultrasonography have emerged, such as Doppler, contrasted ultrasound and elastography, which increase the diagnostic accuracy. Doppler provides information on vascular architecture and hemodynamic aspects of blood vessels. Contrast ultrasonography allows to determine parameters related to the blood perfusion of structures by contrast agents (eg, microbubbles), thus defining high and low intensity patterns of vascular architecture. ARFI elastography provides assessment of tissue stiffness both qualitatively, using elastograms, and quantitative, using shear speeds. It is hoped that this review can contribute with relevant information to readers and veterinarians in the area of asound and animal reproduction.(AU)


Assuntos
Animais , Cães , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Doppler/métodos , Equipamentos para Diagnóstico/veterinária , Técnicas de Imagem por Elasticidade/métodos , Vasos Sanguíneos/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Microbolhas/veterinária , Imagem de Perfusão/veterinária , Rigidez Vascular/fisiologia
3.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1487655

Resumo

ABSTRACT: The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.


RESUMO: O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.

4.
Pesqui. vet. bras ; 41: e06785, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-32489

Resumo

The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.(AU)


O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.(AU)


Assuntos
Animais , Cães , Anormalidades Congênitas , Ultrassonografia , Insuficiência Renal Crônica , Técnicas de Imagem por Elasticidade , Perfusão , Rim
5.
Pesqui. vet. bras ; 41: e06785, 2021. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1250490

Resumo

The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.(AU)


O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.(AU)


Assuntos
Animais , Cães , Anormalidades Congênitas , Ultrassonografia , Insuficiência Renal Crônica , Técnicas de Imagem por Elasticidade , Perfusão , Rim
6.
Tese em Português | VETTESES | ID: vtt-222041

Resumo

Os objetivos dos estudos foram realizar a avaliação da hemodinâmica gestacional fisiológica, envolvendo a dinâmica vascular da artéria umbilical e a perfusão de placentas normais e funcionais e então estabelecer parâmetros qualitativos e quantitativos de referência para cadelas braquicefálicas saudáveis e avaliar a vascularização e perfusão placentária em cadelas com anormalidades fetais proximas ao parto. Foram utilizados 44 fetos, provenientes de 22 cadelas braquicefálicas, e 9 fetos com anormalidades. Os exames ultrassonográficos foram realizados nos três terços da gestação, aos 25, 45 e 58 dias, neste ultimo momento, dos fetos com anormalidade gestacionais. Utilizou-se aparelho ACUSON S2000/SIMENS e transdutor multifrequencial matricial e linear. Foram avaliados dois fetos de cada fêmea, preferencialmente os localizados próximos a região de ovário. O modo doppler espectral foi utlizado para mensuração eletrônica das variáveis dopplerfluxométricas da artéria umbilical: velocidade sistólica (VS), velocidade diastólica (VD), tempo médio de velocidade mínima (TaMin), tempo médio de velocidade máxima (TaMax), índice de pulsatilidade (IP) e índice de resistência (IR). Após, foi realizada a CEUS utilizando o software de imagem harmônica (CADENCE) na avaliação qualitativa do contraste ultrassonográfico, identificando: uniformidade do preenchimento nas regiões placentárias (homogêneo ou heterogêneo), áreas de hipoperfusão, e se ao longo do período gestacional o padrão de realce sofreria alterações em relação a entrada e saída do contraste; e na quantitativa dos parâmetros de perfusão placentários: pico de intensidade do contraste (Fpeak em % de pixels), tempo para o pico (Ftp em s), tempo médio de transmissão (Fmtt em s), área sob a curva (Fauc) e inclinação da curva de entrada em pixels (Fpixels). As variáveis coletadas foram comparadas entre os fetos avaliados (normais e anormais) e entre os momentos pelo teste T-Student e ANOVA e correlacionadas pelo teste de Spearman. Nos fetos saudáveis as variáveis VS, VD, TaMax e TaMin aumentaram significativamente do M2 para o M3 (P<0,05), enquanto o IP (P<0,043) e o IR (P<0,001) diminuíram. Os parâmetros avaliados no CEUS permaneceram constantes durante todos os terços da gestação (P<0,05). Qualitativamente, em todos os momentos avaliados, a distribuição do contraste foi homogênea no tecido placentário. Foi possível acompanhar as adaptações vasculares materno-fetais conforme a progressão da gestação em cadelas, de forma a atender às crescentes demandas metabólicas do feto. Já nos fetos que apresentaram hidropsias os valores de Doppler foram semelhantes aos obtidos nos saudáveis (P<0,05), porém na avaliação com CEUS foi possivel verificar uma distribuição heterogênea, com menor intensidade de preenchimento do tecido placentário e um atraso nos tempos de perfusão (P<0,05), com acurácia diagnóstica próxima de 75%. A associação das técnicas dopplerfluxométricas e CEUS permitiu estabelecer parâmetros qualitativos e quantitativos da hemodinâmica gestacional fisiológica, em todos os terços da gestação, sendo possível correlacionar com desenvolvimento e manutenção de todo processo gestacional, sem evidência de alterações significativas na fisiologia do binômio materno-fetal; assim a CEUS demonstrou ser aplicável na detecção de falhas no preenchimento vascular placentário (disfunção tecidual) em fetos com anasarca e hidrocefalia. Adicionalmente,foram descritos os achados ultrassonográficos de alterações encontrados durante o exame pré natal, de alterações nas estruturas renais de um feto pela da ultrassonografia de alta definição, com descrito no relato de caso presente nesta tese.


The objectives of the studies were to evaluate the physiological gestational hemodynamics, involving the vascular dynamics of the umbilical artery and the perfusion of normal and functional placentas, and then to establish qualitative and quantitative reference parameters for healthy brachycephalic bitches and to evaluate the vascularization and placental perfusion in bitches with fetal abnormalities close to delivery. 44 fetuses were used, from 22 brachycephalic bitches, and 9 fetuses with abnormalities. Ultrasound examinations were performed in the three thirds of pregnancy, at 25, 45 and 58 days, at this last moment, of fetuses with gestational abnormalities. An ACUSON S2000 / SIMENS device and a multi-frequency matrix and linear transducer were used. Two fetuses from each female were evaluated, preferably those located near the ovary region. The spectral doppler mode was used to electronically measure the dopplerfluxometric variables of the umbilical artery: systolic velocity (VS), diastolic velocity (RV), mean minimum velocity time (TaMin), mean maximum velocity time (TaMax), pulsatility index ( IP) and resistance index (IR). Afterwards, CEUS was performed using the harmonic imaging software (CADENCE) in the qualitative evaluation of the ultrasound contrast, identifying: uniformity of filling in the placental regions (homogeneous or heterogeneous), areas of hypoperfusion, and whether, throughout the gestational period, the pattern of enhancement would change in relation to the entry and exit of the contrast; and in the quantity of placental perfusion parameters: peak contrast intensity (Fpeak in% of pixels), time to peak (Ftp in s), average transmission time (Fmtt in s), area under the curve (Fauc) and slope of the input curve in pixels (Fpixels). The variables collected were compared between the fetuses evaluated (normal and abnormal) and between the moments by the T-Student and ANOVA tests and correlated by the Spearman test. In healthy fetuses, the variables VS, VD, TaMax and TaMin increased significantly from M2 to M3 (P <0.05), while PI (P <0.043) and IR (P <0.001) decreased. The parameters evaluated in CEUS remained constant during all thirds of pregnancy (P <0.05). Qualitatively, in all evaluated moments, the distribution of contrast was homogeneous in the placental tissue. It was possible to monitor the maternal fetal vascular adaptations according to the progression of gestation in bitches, in order to meet the increasing metabolic demands of the fetus, which allow it to develop properly. In the case of fetuses that presented hydrops, the Doppler values were similar to those obtained in the healthy ones (P <0.05), however, in the evaluation with CEUS it was possible to verify a heterogeneous distribution, with less intensity of filling of the placental tissue and a delay in the times of perfusion (P <0.05), with diagnostic accuracy close to 75%. The association of flow-through doppler techniques and CEUS allowed to establish qualitative and quantitative parameters of physiological gestational hemodynamics, in all thirds of pregnancy, of healthy brachycephalic bitches, being possible to correlate with the development and maintenance of the whole gestational process of healthy bitches, without evidence of significant changes in the physiology of the maternal fetal binomial; thus, CEUS proved to be applicable in the detection of flaws in the placental vascular filling (tissue dysfunction) in fetuses with anasarca and hydrocephalus. In addition, the sonographic findings of alterations found during the prenatal examination, of alterations in the renal structures of a fetus by that of high definition ultrasonography, have been described, as described in the case report in this thesis.

7.
Arq. bras. med. vet. zootec. (Online) ; 67(6): 1528-1532, Nov.-Dec. 2015. ilus
Artigo em Inglês | VETINDEX | ID: vti-334113

Resumo

The aim of this study was to evaluate the splenic parenchyma of dogs with subclinical ehrlichiosis using Doppler and contrast-enhanced ultrasonography and provide reference values for this organ in affected animals. Seventeen dogs naturally infected with E. canis were selected for this study. Splenic parenchyma echotexture and echogenicity, size and borders were determined by ultrasound scan. The vascular indices of the splenic artery were determined by Doppler. SonoVue, at 0.1mL per animal, was used in microbubble contrast-enhanced ultrasonography to determine wash in, wash out and peak enhancement time in the splenic tissue. B-mode ultrasonography revealed splenomegaly with rounded borders, heterogeneous echotexture and mixed echogenicity. The vascular indices of the splenic artery were: systolic velocity of 22.59±8.07cm/s, diastolic velocity of 5.25±4.66cm/s and resistance index of 0.71±0.14; values not yet reported in Veterinary Medicine. Contrast-enhanced ultrasonography recorded wash in time of 5.31±0.7s, peak enhancement time of 18.56±2.90s and wash out time of 94.56±35.21s. The combination of conventional ultrasonography of the spleen and hemodynamic evaluation by Doppler and contrast-enhanced ultrasonography is important for the diagnosis of canine ehrlichiosis and could help monitor the clinical evolution of subclinical cases(AU)


O objetivo deste estudo foi avaliar o parênquima esplênico de cães com erliquiose na fase subclínica, por meio do Doppler e da ultrassonografia por contraste com microbolhas. Dezessete cães naturalmente infectados por E. canis na fase subclínica foram selecionados para este estudo. Por meio da ultrassonografia, avaliou-se a ecotextura, a ecogenicidade, o tamanho e os bordos do baço e, pelo Doppler, foram determinados os índices vasculares da artéria esplênica dos cães. Para a avaliação por contraste com microbolhas, foi utilizado SonoVue, na dosagem de 0,1mL por animal, e determinou-se o tempo de entrada e saída, bem como o pico de realce no tecido esplênico. Ao exame modo-B, foram observadas esplenomegalia com presença de bordas arredondadas, ecotextura heterogênea e ecogenicidade mista do baço. Ao Doppler, foram encontrados valores para os índices vasculares da artéria esplênica: velocidade sistólica: 22,59±8,07cm/s; velocidade diastólica: 5,25±4,66cm/s; e índice de resistência: 0,71±0,14, valores ainda não descritos em veterinária. Pela ultrassonografia com contraste, observaram-se valores para wash-in de 5,31±0.7s, pico de realce de 18,56±2.90s e wash-out de 94,56±35.21s. A ultrassonografia convencional do baço de cães com erliquiose, associada com a utilização do método Doppler e a ultrassonografia contrastada, é uma importante ferramenta na triagem diagnóstica e pode auxiliar a monitoração e a evolução de animais na fase subclínica(AU)


Assuntos
Animais , Cães , Ehrlichiose , Ehrlichiose/veterinária , Baço , Baço/virologia , Ultrassonografia Doppler de Pulso/veterinária , Portador Sadio/veterinária
8.
Tese em Português | VETTESES | ID: vtt-220658

Resumo

Introdução: Artemia salina (camarão de salmoura) é um microcrustáceo aquático utilizado para testes de ecotoxicidade. Isoterápicos (ou preparações homeopáticas feitas a partir do mesmo agente causador da doença) são comumente usados na clínica como recurso para atenuação de sintomas de intoxicações, contudo, pouco se sabe sobre seus efeitos em animais aquáticos. Dado que a poluição marinha é um dos problemas mais importantes deste século, a busca de soluções para reduzir seu impacto sobre sistemas vivos é tema de alto interesse. Nesse trabalho, a Artemia salina e o cloreto de mercúrio foram utilizados como modelo experimental para o estudo dos possíveis efeitos protetores do isoterápico de cloreto de mercúrio na intoxicação de animais aquáticos pelo mesmo sal. Objetivo: a) avaliar possíveis efeitos atenuadores da toxicidade ao cloreto de mercúrio pelos isoterápicos; b) avaliar a presença de mercúrio solúvel e insolúvel na água; c) avaliar possíveis interferências das fases da lua nos efeitos do tratamento sobre a eclosão de cistos, dado que a Artemia salina é um animal marinho e sujeito a tais oscilações. Métodos: Os isoterápicos (Mercurius corrosivus) foram preparados em água pura estéril, a partir de matrizes de cloreto de mercúrio homeopáticas, preparadas previamente em farmácia homeopática credenciada na ANVISA. Os tratamentos foram feitos em cego. Placas de cultura de 96 poços foram utilizadas para promover a eclosão de cistos de Artemia salina em água do mar artificial de maneira controlada. Cistos expostos a cloreto de mercúrio 39 µg/mL (concentração letal 10%) foram tratados durante 48 horas com as seguintes diluições (potências) de Mercurius corrosivus: 6 cH, 30 cH, 200 cH, para observação da taxa de eclosão. Os controles foram: cistos não desafiados, cistos desafiados e tratados com água pura, água pura sucussionada ou Ethilicum 1cH (veículo). Quatro séries de nove experimentos foram realizadas, sendo cada série executada em uma fase distinta da lua para averiguação de possíveis resultados falso-positivos. Fotomicrografias e vídeos de 13 segundos foram capturados de cada poço, após 24 e 48 horas, sendo os vídeos analisados pelo software Image J, plug-in Trackmate para quantificação da mobilidade dos náuplios nascidos. O número de náuplios e de cistos não eclodidos foi computado para o cálculo da taxa de eclosão. Análises físico-químicas (CV/AAS) e microscópicas (MEV / EDS) da água também foram feitas, para quantificação de mercúrio solúvel e precipitado, respectivamente. Os dados foram analisados por ANOVA de múltiplas vias seguida de Tukey, sendo p0,05. Resultados e conclusões: A fase da lua tem influência na velocidade da eclosão dos cistos, sendo esta mais precoce nas luas minguante e cheia. Embora os efeitos dos tratamentos tenham sido mais evidentes na lua cheia, não houve interação estatística entre fases da lua e tratamentos. Atraso significante (p<0,05) na eclosão dos cistos foi observado após tratamento com Mercurius corrosivus 30 cH, em relação aos controles igualmente intoxicados, independentemente da fase da lua, sugerindo melhor adaptação dos cistos ao ambiente hostil. Náuplios nascidos na lua cheia tratados com Mercurius corrosivus 200 cH ou Ethilicum 1cH apresentaram maior mobilidade. Todas as amostras de água colhidas na lua cheia e tratadas com preparações submetidas à agitação (sucussão), incluindo a água sucussionada e o Ethilicum 1cH, mostraram redução na concentração de mercúrio solúvel sem que houvesse precipitação de mercúrio insolúvel na água ou amostras biológicas, sugerindo ação facilitadora de nano e microbolhas na evaporação de mercúrio volátil. Os efeitos específicos do Mercurius corrosivus ainda necessitam de estudos futuros para esclarecimento de seus mecanismos, mas a deposição de oxigênio e carbono na superfície dos elementos orgânicos e o aumento de cloro nas partículas minerais em suspensão na água sugerem o envolvimento de processos relacionados à troca iônica.


Introduction: Brine shrimp (brine shrimp) is an aquatic microcrustacean used for ecotoxicity tests. Isotherapeutic homeopathic preparations, made from the causative agent of a certain disease, are commonly used as a clinical resource for attenuation of intoxication symptoms, however, little is known about their effects on aquatic animals. Given that marine pollution is one of the most important problems of this century, finding solutions to reduce its impact on living systems is a matter of high interest. In this work, Artemia salina and mercury chloride were used as an experimental model to study the possible protective effects of isotherapic preparations on poisoning of aquatic animals by the same salt. Objective: a) to evaluate possible attenuating effects of mercury chloride toxicity by isotherapics; (b) evaluate the presence of soluble and insoluble mercury in water; (c) evaluate possible interference of the moon phases on the effects of treatment on cyst eclosion, since Artemia salina is a marine animal and subject to such oscillations. Methods: Isotherapics (Mercurius corrosivus) were prepared in sterile pure water from homeopathic mercury chloride matrices, previously prepared in an ANVISA-accredited homeopathic pharmacy. Treatments were done in blind. 96-well culture plates were used to promote the eclosion of Artemia salina cysts in artificial seawater, in a controlled manner. Cysts exposed to 39 µg/mL mercury chloride (lethal concentration 10%) were treated for 48 hours with the following Mercurius corrosivus dilutions (potencies): 6 cH, 30 cH, 200 cH, for eclosion rate observation. The controls were: non-challenged cysts, challenged cysts treated with pure water, pure stirred water or Ethilicum 1cH (vehicle). Four series of nine experiments were performed, each series being performed in a distinct phase of the moon, to evaluate possible false-positive effects. Photomicrographs and 13 second videos were captured from each well after 24 and 48 hours, and the videos were analyzed by Image J software, Trackmate plug-in to quantify the mobility of born nauplii. The number of nauplii and non-hatched cysts was computed to calculate the eclosion rate. Physicochemical (CV / AAS) and microscopic (SEM / EDS) analyzes of water were also performed to quantify soluble and precipitated mercury, respectively. Data were analyzed by multiple-way ANOVA followed by Tukey, being p0.05. Results and conclusions: The moon phase influences the rate of cysts eclosion, which is earlier in the waning (third quarter) and full moons. Although the effects of treatments were more evident in the full moon, there was no statistical interaction between moon phases and treatments. Significant delay (p<0.05) in cyst eclosion was observed after treatment with Mercurius corrosivus 30 cH compared to intoxicated controls, independent of the moon phase, suggesting better cyst adaptation to hostile environment. Nauplii born in the full moon and treated with Mercurius corrosivus 200 cH or Ethilicum 1cH showed increase in their mobility. All water samples taken at full moon and treated with agitated (succussed) preparations, including succussed water and vehicle, showed reduction in soluble mercury concentration without any correspondence with insoluble mercury precipitation in the water, suggesting a facilitating action of nano and microbubbles on volatile mercury evaporation. The specific effects of Mercurius corrosivus still need further studies to clarify its mechanisms, but oxygen and carbon deposition on the surface of organic elements and increased chlorine in mineral particles suspended in water suggest the involvement of ion exchange processes.

9.
Tese em Português | VETTESES | ID: vtt-212978

Resumo

A farmacologia diagnóstica é um importante nicho de pesquisa dentro da oftalmologia veterinária, tamanha sua importância e impacto de suas descobertas. A gama de possibilidades e de drogas disponíveis aumenta na mesma velocidade em que as pesquisas avançam rumo à precisão da localização do foco da doença. Para isso, a compreensão dos diferentes mecanismos de ação, bem como limitações e possíveis alterações no organismo ou do meio que o cerca, são de suma importância para evitar distorções na interpretação dos resultados. No primeiro capítulo aborda-se uma modalidade farmacológica relativamente nova no que diz respeito ao diagnóstico, principalmente na oftalmologia veterinária. Trata-se de uma ideia de aplicação ocular de uma solução de microbolhas que já vinha sendo empregada como contraste na ultrassonografia de outros órgãos ou no próprio bulbo ocular mas com outras finalidades. Nesta proposta foram abordadas diferentes espécies de aves, as quais receberam uma injeção intravenosa da solução de microbolhas para evidenciar o pecten, uma iniciativa até então inédita no meio científico. Constatou-se que o pecten foi evidenciado pelo contraste sem extravasamento deste para o corpo vítreo e sem efeitos colaterais para as aves na dose utilizada. No segundo capítulo, os principais corantes vitais utilizados na oftalmologia médica e veterinária foram testados para sua capacidade de inibição ou permissibilidade do crescimento de determinadas espécies bacterianas. Testes de Kirk-Bauer e de eficácia antimicrobiana foram realizados a fim de verificar as capacidades citadas anteriormente em diferentes formulações para os mesmos corantes, ora em strips, ora em soluções, neste caso com ou sem conservantes. Os resultados mostraram que cuidados devem ser tomados principalmente com fluoresceína sem conservante para evitar o crescimento de Escherichia coli e Pseudomonas aeruginosa, sendo aconselhável não utilizar este corante nesta condição. Concluiu-se também que coletas para cultura e antibiograma devem ser realizadas antes de se corar a superfície ocular devido ao potencial antimicrobiano de alguns corantes


Diagnostic pharmacology is an important research niche within veterinary ophthalmology due to its importance and impact of its findings. The range of possibilities and drugs available increases at the same rate as research advances toward the precise location of the disease's focus. For this, the understanding of the different mechanisms of action, as well as limitations and possible alterations in the organism or the surrounding environment, are extremely important to avoid distortions in the interpretation of the results. The first chapter covers a relatively new pharmacological modality regarding diagnosis, especially in veterinary ophthalmology. It is an idea of ocular application of a microbubble solution that has already being used as a contrast in the ultrasound of other organs or in the eye bulb itself but for other purposes. Different species of birds, which received an intravenous injection of the microbubbles solution to highlight the pecten were approached in this proposal, an initiative previously unheard of in the scientific environment. It was found that pecten was evidenced without extravasation by the contrast from it to the vitreous body and without side effects to the birds at the dose used. In the second chapter, the main vital dyes used in medical and veterinary ophthalmology were tested for their ability to inhibit or allow the growth of certain bacterial species. Kirk-Bauer and antimicrobial efficacy tests were performed to verify the aforementioned capabilities in different formulations for the same dyes, time in strips, time in solutions, in this case with or without preservatives. The results showed that care should be taken mainly with preservative-free fluorescein to prevent the growth of Escherichia coli and Pseudomonas aeruginosa. It is advisable not to use this dye in this condition. It was also concluded that sample collection for culture and sensitivity should be performed before staining the ocular surface due to the antimicrobial potential of some dyes.

10.
Tese em Português | VETTESES | ID: vtt-213451

Resumo

Atualmente, a ultrassonografia é o método de escolha para avaliação pancreática, sendo imprescindível como auxílio diagnóstico na detecção de anormalidades. Com a tecnologia inovadora dos equipamentos, surgiram técnicas complementares à ultrassonografia modo-B, que contribuem para o diagnóstico de alterações pancreáticas. O objetivo deste estudo foi avaliar se a elastografia, a ultrassonografia Doppler e contraste por microbolhas permitem identificar alterações pancreáticas de cães. Foram selecionados 25 cães, machos e fêmeas, com idade entre 1-14 anos, 16 animais sem sinais de alterações clínicas de doença pancreática (GS) e nove com suspeita clínica de pancreatite (GD). Os 16 animais saudáveis não apresentaram alterações à ultrassonografia modo-B nem à elastografia qualitativa, a velocidade média da onda de cisalhamento (SWV) foi maior (1,9±0,3) no GS (p=0,014) do que no GD (2,4±0,5 m/s) resultando numa sensibilidade de 78%, e especificidade de 69% na identificações de alterações pancreáticas. Ao Doppler não foram verificadas diferenças entre os grupos, nem no mapeamento colorido e nem no Doppler pulsado. Os valores obtidos na CEUS não obtiveram diferença entre os grupos. A elastografia apresenta-se como técnica promissora para identificação das alterações do pâncreas, enquanto que as demais técnicas não mostraram acurácia diagnóstica.


Currently, ultrasonography is the method of choice for pancreatic evaluation, and is essential as a diagnostic aid in the detection of abnormalities. With the innovative technology of the equipment, techniques complementary to B-mode ultrasonography have emerged, which contribute to the diagnosis of pancreatic changes. The objective of this study was to evaluate whether the elastography, Doppler ultrasonography and microbubble contrast allow the identification of pancreatic changes in dogs. Twenty-five male and female dogs, aged 1-14 years, 16 animals with no clinical signs of pancreatic disease (GS) and nine with clinical suspicion of pancreatitis (GD) were selected. The 16 healthy animals showed no change in B-mode or qualitative elastography, mean shear wave velocity (SWV) was greater (1.9±0.3) in GS (p=0.014) than in GD (2.4±0.5 m / s) resulting in a sensitivity of 78%, and specificity of 69% in the identification of pancreatic changes. Doppler showed no differences between groups, either in color mapping or in pulsed Doppler. The values obtained in the CEUS did not differ between groups. Elastography presents as a promising technique for the identification of pancreas alterations, while the other techniques did not show diagnostic accuracy.

11.
Tese em Português | VETTESES | ID: vtt-212966

Resumo

A sepse é uma síndrome clínica que ocasiona alta morbimortalidade em humanos e animais, devido à disfunção orgânica a qual conduz, sendo a principal complicação a lesão renal aguda (LRA), originada por alteração da perfusão dentre outros fatores. No entanto, até o presente momento as técnicas utilizadas para o diagnóstico precoce de alterações na perfusão renal são pouco acuradas, invasivas ou de alto risco para o paciente. Por tal motivo, este estudo clínico avaliou parâmetros clínicos, hematológicos, urinários, de ultrassonografia Modo-B, Doppler espectral e contrastada por microbolhas (CEUS), utilizando o exame histopatológico da biopsia renal como padrão diagnóstico de LRA, em 20 cadelas com piometra de origem natural como modelo experimental de sepse. Objetivou-se identificar alterações patofisiológicas que expliquem o desenvolvimento da LRA e sepse neste tipo de pacientes e verificar a acurácia dos métodos estudados para o diagnóstico desta lesão, utilizando um grupo de 12 pacientes saudáveis como controle. Todas as pacientes apresentaram algum grau de lesão renal de diversas origens celulares e 40% apresentaram-se em sepse. A LRA pôde ser explicada em 57% dos casos por alteração da hemodinâmica renal, principalmente redução da magnitude e velocidade do fluxo sanguíneo renal avaliados pelo Doppler e da perfusão cortical pela CEUS; e em 22% dos casos por alterações inflamatórias sistémicas, associadas à redução da concentração plasmática de albumina e aumento das globulinas. Os parâmetros que apresentaram melhor valor diagnóstico para LRA (acurácia > 80%) foram: razão proteína-creatinina urinária (UPC), albumina sérica, tempo médio de velocidade na artéria renal (TaMin), indice de pulsatilidade (IP), relação comprimento renal-aorta (RelCompAor) e pico de realce do contraste no córtex renal. A sepse e as alterações na albumina, PaO2, TaMin, hematócrito, UPC, RelCompAor, fosfatase alcalina e IP, associaram-se a degeneração tubular, infiltração inflamatória, necrose tubular aguda, fibrose intersticial, glomerulonefrite membranoproliferativa e glomerulonefrite membranosa, mais severas, sendo estas as lesões renais encontradas na análise histopatológica. Além disso, sugere-se a utilização da UPC ao invés da creatinina como método de avaliação renal no escore SOFA para determinação de sepse em cães.


Sepsis is a clinical syndrome that causes high morbidity and mortality in humans and animals, due to the organic dysfunction it leads to. The main complication is acute kidney injury (AKI), caused by changes in perfusion, among other factors. Unfortunately, to date the techniques used for the early diagnosis of changes in renal perfusion are not accurate, invasive or at high risk for the patient. Therefore, this clinical study evaluated clinical, hematological, urinary and utrasonographic B-mode, spectral Doppler and microbubble contrast (CEUS) techniques, using histopathological exam of renal biopsy as the diagnostic standard of AKI in 20 bitches with pyometra of natural causes as an experimental model of sepsis. The aim was to identify pathophysiological changes that explain the development of AKI and sepsis in this kind of patients and to verify the accuracy of the methods studied for the diagnosis of this lesion, using a group of 12 healthy control patients. All animals with pyometra presented some degree of renal damage from multiple cellular origins and 40% presented with sepsis. The LRA could be explained in 57% of cases due to renal hemodynamics changes, mainly reduction of renal blood flow magnitude and velocity evaluated by Doppler ultrasonography and cortical perfusion evaluated by CEUS; and in 22% of cases due to systemic inflammatory alterations, associated to reduction of plasmatic concentration of albumin and increase of globulins. The parameters that presented the best diagnostic value for AKI (accuracy> 80%) were: urinary protein-creatinine ratio (UPC), serum albumin, mean renal artery velocity (TaMin), pulsatility index (PI), kidney length/aorta ratio (KLAorR) and peak contrast enhancement in the renal cortex. Sepsis and alterations in albumin, PaO2, TaMin, hematocrit, UPC, KLAorR, alkaline phosphatase and PI were associated with aggravation of tubular degeneration, inflammatory infiltration, acute tubular necrosis, interstitial fibrosis, membranoproliferative glomerulonephritis and membranous glomerulonephritis, these being the renal lesions found in the histopathological analysis. In addition, we suggest the use of UPC instead of creatinine as a renal evaluation in the SOFA score for determination of sepsis in dogs.

12.
Tese em Português | VETTESES | ID: vtt-202242

Resumo

O baço é um órgão que desenvolve inúmeras funções importantes no organismo e é um dos principais locais para o desenvolvimento de tumores primários, metastáticos e afecções do sistema hematopoiético, por isso realizar uma avalição apurada neste órgão é de suma importância, em Medicina veterinária, particularmente em cães devido à importância econômica, afetiva e de similaridade cientifica para o homem.Todavia, amaioria dos métodos utilizados para o diagnóstico conclusivo de enfermidades esplênicas são métodos invasivos, sendo que os nãos invasivos perdem em sensibilidade e especificidade, dificultando que se proceda a um correto diagnóstico. Sendo assim, este estudo prospectivo visou avaliar a aplicabilidade das novas técnicas ultrassonográficas para avaliação esplênica de caninos, utilizando a elastografia ARFI (qualitativa e quantitativa), Doppler e ultrassonografia por contraste com microbolhas, com o intuito de determinar valores ainda não descritos na veterinária, as quais forneçam subsídios suficientes para se obter um diagnóstico conclusivo sobre a condição esplênica, nesta espécie. Os resultados obtidosnos cães saudáveis, por meio da ultrassonografia modo B apresentaram-se normais, sendo que na elastografia qualitativa, as porções esplênicas avaliadas apresentaram-se não deformáveis, com parênquima homogêneo de cor cinza escuro (hard). Na elastografia quantitativaos valores médios da velocidade de cisalhamento foram de 2,32 m/s para a cabeça, 2,16 m/s para o corpo e 2,25 m/s para a cauda do baço, não apresentando diferença estatística (P > 0,05). Ao exame contrastado, foram avaliados animais com erliquiose na fase subclínica, e estes apresentaram ao exame modo-B, esplenomegalia com presença de bordas arredondadas, ecotextura heterogênea e ecogenicidade mista do baço. Ao Doppler, verificou-se valores para os índices vasculares da artéria esplênica: velocidade sistólica: 22,59 ± 8,07 cm/s; velocidade diastólica: 5,25 ± 4,66 cm/s; e índice de resistência: 0,71 ± 0,14. Pela ultrassonografia com contraste observaram-se valores para wash-in de 5,31 ± 0,7s, pico de realce de 18,56 ± 2,90s e wash-out: 94,56 ± 35,21s. A elastografia ARFI é um método recente que pode fornecer dados de base para o baço e permitir a utilização futura desta técnica, na avaliação de cães com doença esplênica. A ultrassonografia convencional do baço de cães com erliquiose associado com a utilização do método Doppler e ultrassonografia contrastada são importantes ferramentas na triagem diagnóstica e podem auxiliar a monitoração e evolução de animais na fase subclínica.


The spleen is an organ develops much important functions in the body and the spleen is one of the main organs prone to the development of primary tumors, metastasis and a broad range of diseases of the hematopoietic system perform assessment of spleen is important. In veterinary medicine, principally in dogs because of economic importance, affective and scientific similarity to humans. However, the most of the methods used for conclusive diagnosis of splenic diseases are invasive methods, noninvasive lose in sensitivity and specificity difficulting proceed to a correct diagnosis. Thus, this study aimed to perform the ultrasound scan of dogs spleen using the elastographic (qualitative and quantitative) Doppler and contrast enhanced ultrasonography. Determining values not described in veterinary, which provide sufficient subsidies to get a conclusive diagnosis of the splenic condition in this species. The results in healthy dogs showed, all splenic segments visualized with the B-mode ultrasonography appeared normal. Different splenic segments examined with qualitative elastography were free of any detectable malformations and the images appeared as homogeneous dark areas. The mean shear velocity values were 2.32 m/s for head, 2.16 m/s for body and 2.25 m/s for tail of the spleen, and they did not vary between the different age groups (P>0.05). In dogs with ehrlichiosis in subclinical phase showed, by B-mode examination, observed splenomegaly with presence of rounded borders and heterogeneous echotexture and mixed echogenicity in spleen. For Doppler found values for vascular indices of the splenic artery: systolic velocity: 22.59 ± 8.07 cm/s; diastolic velocity: 5.25 ± 4.66 cm/s; and resistance index: 0.71 ± 0.14. For contrast enhanced ultrasonography observed values for wash-in: 5.31 ± 0.7s, peak enhancement: 18.56 ± 2.90s and wash-out: 94.56 ± 35.21s. The ARFI elastography is a new method and it may aid in the diagnosis and evaluation of splenic abnormalities routinely assessed in veterinary practice. The conventional ultrasonography of the spleen in dogs with ehrlichiosis associated with hemodynamic evaluation by Doppler and contrast enhanced ultrasonography are important tools for diagnosis trial and could help the monitoring clinical evolution in subclinical phase.

13.
Tese em Português | VETTESES | ID: vtt-202511

Resumo

As pesquisas envolvendo a reprodução de gatos domésticos comumente baseiam-se em análise macroscópica e andrológica do sistema reprodutor desses animais, não havendo nenhum estudo até o momento sobre a avaliação ultrassonográfica dos testículos nesta espécie. Sendo assim, este estudo prospectivo visou realizar a varredura ultrassonográfica dos testículos de 45 gatos adultos domésticos, utilizando as técnicas Modo B, Doppler e Ultrassonografia por Contraste com Microbolhas. Os resultados obtidos ao exame ultrassonográfico modo B demonstraram as estruturas testiculares com ecotextura homogênea e com ecogenicidade dentro da normalidade (semelhante à ecogenicidade do tecido esplênico), com presença de linha mediastinal evidente. Ao Doppler colorido testicular, foi possível verificar artéria testicular com padrão de ondas arterial e monofásico, em região de cordão espermático. Utilizando o Doppler Espectral, obtiveram-se os índices vasculares dos testículos direito e esquerdo, respectivamente: VS = 6.23 cm/s, VD = 2.77 cm/s e IR = 0.53; VS = 6.73 cm/s, VD = 2.8 cm/s e IR = 0.54. A avaliação ultrassonográfica contrastada por microbolhas não resultou em efeitos colaterais aos animais, apresentando-se de aplicação confiável e gerando imagens de qualidade. O contraste preencheu as estruturas vasculares subcapsulares, com moderado realce homogêneo do parênquima, além de rápida redução da ecogenicidade após o pico de realce. Os valores de tempo para o contraste de microbolhas, considerando tempo de entrada, pico de realce e tempo de saída para os testículos direito e esquerdo foram, respectivamente: tempo de entrada = 10.76 s, pico de realce = 21.50 s e pico de saída = 81.81; tempo de entrada = 8.78 s, pico de realce = 21.62 s e tempo de saída = 75.36. Esses exames foram facilmente aplicados em gatos domésticos e devem ser utilizados como técnicas auxiliares no diagnóstico de anormalidades testiculares nesta espécie.


Research involving breeding of domestic cats are commonly based on macroscopic and andrologic analysis, there is no study to date with sonographic evaluation of domestic cats testicle. Thus, this study aimed to perform the ultrasound scan of 45 adult domestic cats testicles, using the techniques of B mode, Triplex Doppler ultrasound and contrast-enhanced. The results showed homogeneous testicles, with normal echogenicity and echotexture, with evident mediastinal line. Testicular artery was observed in the spermatic cord with tortuous patter and showed monophasic-patterned waves and low vascular resistance and with systolic peak evident. Values of indices vascular were as follows: SV = 6.73 cm/s, DV = 2.8 cm/s and RI = 0.54 for left testicles; and SV = 6.23 cm/s, DV = 2.77 cm/s and RI = 0.53 for right testicles. The contrast-enhanced resulted in no side effects, being reliable and generating quality images. Contrast filled the subcapsular vascular structures and after a few seconds, a homogeneous moderate enhancement of the parenchyma, with parenchymal vessels still distinguishable and after the peak phase, a rapid homogeneous decrease in echogenicity. Values of time for contrast-enhanced ultrasonography were as follows: wash-in = 8.78 s, peak enhancement = 21.62 s and wash-out = 75.36 for left testicles; and wash-in = 10.76 s, peak enhancement = 21.50 s and washout = 81.81 for right testicles. The examination in Doppler mode showed testicular artery with monophasic-patterned waves in spermatic cord. These tests were easily applied in domestic cats and should be used as auxiliary techniques in the diagnosis of testicular abnormalities in this species.

14.
Clín. Vet. (São Paulo, Ed. Port.) ; 17(101): 108-114, 2012.
Artigo em Inglês, Espanhol, Português | VETINDEX | ID: biblio-1480860

Resumo

Nas últimas duas décadas, a ultrassonografia apresentou diversas inovações tecnológicas, algumas até bem acessíveis economicamente. Estudos recentes comprovam que a ultrassonografia com contraste por microbolhas possibilita a avaliação da perfusão dos órgãos e, quando associada ao Doppler, aumenta a capacidade de detecção da sua vascularização. Esses novos conceitos permitem estudar o comportamento hemodinâmico de lesões focais em relação ao tecido normal, e a principal utilização se relaciona à diferenciação de tumores. Os resultados dessa técnica parecem promissores, sugerindo acurácia diagnóstica semelhante à de outros métodos de diagnóstico por imagem, como a tomografia contrastada e a imagem em ressonância magnética. Este trabalho teve como objetivo rever na literatura veterinária as principais possibilidades diagnósticas de utilização dessa técnica nos órgãos da cavidade abdominal de pequenos animais.


In the last two decades, there have been several technological improvements in ultrasonography, some of which are very accessible economically. Recent studies show that contrast-enhanced ultrasonography with microbubbles enables the assessment of perfusion, and increases the detection of organ vascularization when used in combination with Doppler. These new concepts allow the study of hemodynamic behavior of focal lesions in relation to the normal tissue, and its main use is related with tumor differentiation. The results of this technique seem promising and suggest similar diagnostic accuracy as other imaging methods, such as computed tomography and magnetic resonance imaging. The aim of this work was to review the main diagnostic possibilities of this technique in the abdominal cavity organs of small animals.


En las últimas décadas la ecografía ha presentado diversos tipos de innovaciones tecnológicas, algunas de éstas accesibles desde el punto de vista económico. Recientes estudios comprobaron que la ultrasonografía de contraste con microburbujas permite el estudio de la perfusión de los órganos y que, cuando se la asocia al Doppler, aumenta la capacidad de detección de la vascularización. Estos nuevos conceptos permiten estudiar el comportamiento hemodinámico de las lesiones focales en relación al tejido normal, siendo su utilización principal la diferenciación de tumores. Los resultados de esta técnica parecen ser prometedores y se sugiere que su capacidad diagnóstica es semejante a la de otros métodos de diagnóstico por imágenes, como la tomografía contrastada y la resonancia magnética. Este trabajo tuvo como objetivo revisar la literatura veterinaria respecto a las posibilidades diagnósticas de esta técnica en la evaluación de los órganos de la cavidad abdominal en pequeños animales.


Assuntos
Animais , Microbolhas , Tomografia , Ultrassonografia Doppler
15.
Clín. Vet. ; 17(101): 108-114, 2012.
Artigo em Inglês, Espanhol, Português | VETINDEX | ID: vti-10428

Resumo

Nas últimas duas décadas, a ultrassonografia apresentou diversas inovações tecnológicas, algumas até bem acessíveis economicamente. Estudos recentes comprovam que a ultrassonografia com contraste por microbolhas possibilita a avaliação da perfusão dos órgãos e, quando associada ao Doppler, aumenta a capacidade de detecção da sua vascularização. Esses novos conceitos permitem estudar o comportamento hemodinâmico de lesões focais em relação ao tecido normal, e a principal utilização se relaciona à diferenciação de tumores. Os resultados dessa técnica parecem promissores, sugerindo acurácia diagnóstica semelhante à de outros métodos de diagnóstico por imagem, como a tomografia contrastada e a imagem em ressonância magnética. Este trabalho teve como objetivo rever na literatura veterinária as principais possibilidades diagnósticas de utilização dessa técnica nos órgãos da cavidade abdominal de pequenos animais.(AU)


In the last two decades, there have been several technological improvements in ultrasonography, some of which are very accessible economically. Recent studies show that contrast-enhanced ultrasonography with microbubbles enables the assessment of perfusion, and increases the detection of organ vascularization when used in combination with Doppler. These new concepts allow the study of hemodynamic behavior of focal lesions in relation to the normal tissue, and its main use is related with tumor differentiation. The results of this technique seem promising and suggest similar diagnostic accuracy as other imaging methods, such as computed tomography and magnetic resonance imaging. The aim of this work was to review the main diagnostic possibilities of this technique in the abdominal cavity organs of small animals.(AU)


En las últimas décadas la ecografía ha presentado diversos tipos de innovaciones tecnológicas, algunas de éstas accesibles desde el punto de vista económico. Recientes estudios comprobaron que la ultrasonografía de contraste con microburbujas permite el estudio de la perfusión de los órganos y que, cuando se la asocia al Doppler, aumenta la capacidad de detección de la vascularización. Estos nuevos conceptos permiten estudiar el comportamiento hemodinámico de las lesiones focales en relación al tejido normal, siendo su utilización principal la diferenciación de tumores. Los resultados de esta técnica parecen ser prometedores y se sugiere que su capacidad diagnóstica es semejante a la de otros métodos de diagnóstico por imágenes, como la tomografía contrastada y la resonancia magnética. Este trabajo tuvo como objetivo revisar la literatura veterinaria respecto a las posibilidades diagnósticas de esta técnica en la evaluación de los órganos de la cavidad abdominal en pequeños animales.(AU)


Assuntos
Animais , Ultrassonografia Doppler , Tomografia , Microbolhas
16.
Clín. Vet. (São Paulo, Ed. Port.) ; 17(101): 96-106, 2012.
Artigo em Inglês, Espanhol, Português | VETINDEX | ID: biblio-1480859

Resumo

A ultrassonografia é um meio de diagnóstico por imagem que reflete e incorpora inovações tecnológicas rapidamente. O uso de agentes de contraste ultrassonográfico é relativamente recente na medicina humana, e ainda mais inovador na veterinária. A técnica vem apresentando resultados otimistas na diferenciação de lesões benignas e malignas. No Brasil, a utilização do contraste ultrassonográfico depende apenas da liberação por parte da Agência Nacional de Vigilância Sanitária (Anvisa). No entanto, o seu uso está condicionado à presença de recursos especiais nos equipamentos, que, em geral, requerem complexidade tecnológica. Com essa expectativa, vimos revisar a literatura publicada a respeito dos princípios físicos da ultrassonografia com contraste por microbolhas, a fim de melhorar a compreensão dessa nova técnica, assim como os potenciais efeitos colaterais dos agentes de contraste atualmente utilizados.


Ultrasonography is an imaging diagnosis technique that reflects and incorporates technological innovations very fast. The use of ultrasound contrast agents is relatively recent in human medicine and even more so in veterinary medicine. This technique has presented promising results in the differentiation between benign and malignant lesions. In Brazil, the use of ultrasound contrast agents depends only on approval by the National Agency for Sanitary Vigilance (ANVISA). However, their use is conditioned to the presence of special features in the equipment, which in general require technological complexity. We therefore reviewed the literature on the physical principles of medical ultrasonography with contrast by microbubbles, in order to improve the understanding of this new technique, as well as the potential side effects of contrast agents currently used.


La ecografía es un medio de diagnóstico por imagen que rápidamente incorpora innovaciones tecnológicas. El uso de agentes de contraste ecográfico es una técnica relativamente reciente en la medicina humana, y es aún más innovador en veterinaria. La técnica presenta resultados optimistas en la diferenciación de lesiones benignas y malignas. En Brasil la utilización de contraste ecográfico depende sólo de la aprobación de la Agencia Nacional de Vigilancia Sanitaria (ANVISA). No obstante, su uso está condicionado a la presencia de recursos especiales en los equipos, que en general necesitan de una tecnología altamente compleja. Con esa expectativa, hemos realizado una revisión de la literatura respecto a los principios físicos de la ecografía de contraste por microburbujas, con el objetivo de mejorar la comprensión de esta nueva técnica, así como evitar los potenciales efectos colaterales de los agentes de contraste que se usan actualmente.


Assuntos
Animais , Agência Nacional de Vigilância Sanitária , Ferimentos e Lesões , Fluorimunoensaio , Vesícula/metabolismo , Vigilância Sanitária
17.
Clín. Vet. ; 17(101): 96-106, 2012.
Artigo em Inglês, Espanhol, Português | VETINDEX | ID: vti-10427

Resumo

A ultrassonografia é um meio de diagnóstico por imagem que reflete e incorpora inovações tecnológicas rapidamente. O uso de agentes de contraste ultrassonográfico é relativamente recente na medicina humana, e ainda mais inovador na veterinária. A técnica vem apresentando resultados otimistas na diferenciação de lesões benignas e malignas. No Brasil, a utilização do contraste ultrassonográfico depende apenas da liberação por parte da Agência Nacional de Vigilância Sanitária (Anvisa). No entanto, o seu uso está condicionado à presença de recursos especiais nos equipamentos, que, em geral, requerem complexidade tecnológica. Com essa expectativa, vimos revisar a literatura publicada a respeito dos princípios físicos da ultrassonografia com contraste por microbolhas, a fim de melhorar a compreensão dessa nova técnica, assim como os potenciais efeitos colaterais dos agentes de contraste atualmente utilizados.(AU)


Ultrasonography is an imaging diagnosis technique that reflects and incorporates technological innovations very fast. The use of ultrasound contrast agents is relatively recent in human medicine and even more so in veterinary medicine. This technique has presented promising results in the differentiation between benign and malignant lesions. In Brazil, the use of ultrasound contrast agents depends only on approval by the National Agency for Sanitary Vigilance (ANVISA). However, their use is conditioned to the presence of special features in the equipment, which in general require technological complexity. We therefore reviewed the literature on the physical principles of medical ultrasonography with contrast by microbubbles, in order to improve the understanding of this new technique, as well as the potential side effects of contrast agents currently used.(AU)


La ecografía es un medio de diagnóstico por imagen que rápidamente incorpora innovaciones tecnológicas. El uso de agentes de contraste ecográfico es una técnica relativamente reciente en la medicina humana, y es aún más innovador en veterinaria. La técnica presenta resultados optimistas en la diferenciación de lesiones benignas y malignas. En Brasil la utilización de contraste ecográfico depende sólo de la aprobación de la Agencia Nacional de Vigilancia Sanitaria (ANVISA). No obstante, su uso está condicionado a la presencia de recursos especiales en los equipos, que en general necesitan de una tecnología altamente compleja. Con esa expectativa, hemos realizado una revisión de la literatura respecto a los principios físicos de la ecografía de contraste por microburbujas, con el objetivo de mejorar la comprensión de esta nueva técnica, así como evitar los potenciales efectos colaterales de los agentes de contraste que se usan actualmente.(AU)


Assuntos
Animais , Vesícula/metabolismo , Agência Nacional de Vigilância Sanitária , Vigilância Sanitária , Ferimentos e Lesões , Fluorimunoensaio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA