Validação clínica do diagnóstico de enfermagem "Resposta disfuncional ao desmame ventilatório" em pacientes adultos internados em Unidade de Terapia Intensiva / Clinical validation of the nursing diagnosis \"Dysfunctional response to ventilatory weaning\" in adult patients admitted to the Intensive Care Unit
Belo Horizonte; s.n; 2017. 202 p. tab, ilus.
Thesis en Pt | BDENF | ID: biblio-1037733
Biblioteca responsable: BR21.1
Ubicación: BR21.1; T-WY100.4, SIVA
RESUMO
Apesar de ser uma intervenção fundamental para o paciente com insuficiência respiratória aguda ou crônica agudizada, a ventilação mecânica é capaz de induzir diversas complicações, que podem aumentar a morbidade e mortalidade de um paciente crítico, tornando-se essencial restabelecer a ventilação espontânea tão logo seja possível. No entanto, retirar um paciente do suporte ventilatório mecânico pode ser mais difícil que mantê-lo, já que o insucesso na extubação tem sido relatado com grande frequência em investigações prévias. Para esses pacientes, o diagnóstico de enfermagem de “Resposta disfuncional ao desmame ventilatório” é estabelecido. No entanto, apesar de ser aceito pela NANDA-I há cerca de 25 anos, esse diagnóstico não é sustentado por evidências científicas e suas características definidoras e fatores relacionados ainda não estão determinados em termos de relevância. Este estudo teve como objetivo geral validar clinicamente o diagnóstico de enfermagem “Resposta disfuncional ao desmame ventilatório” em pacientes adultos internados em Unidades de Terapia Intensiva de Belo Horizonte, Minas Gerais. Trata-se de um estudo conduzido em duas etapas revisão integrativa da literatura e validação clínica. Na primeira etapa, foram identificados na literatura indicadores clínicos de determinação da falha do desmame ventilatório e fatores relacionados ao desenvolvimento deste problema. Na segunda etapa foi estimada a incidência e densidade de incidência deste diagnóstico na amostra estudada, além de observados os indicadores clínicos de determinação do insucesso do desmame ventilatório e seus fatores relacionados. Foi conduzido um estudo do tipo coorte concorrente, no período de 12 meses, com 93 pacientes internados em quatro Unidades de Terapia Intensiva de dois hospitais gerais e de ensino. A associação...
ABSTRACT
Although it is a fundamental intervention for the patient with acute or chronic respiratory insufficiency, mechanical ventilation is capable of inducing several complications, which may increase the morbidity and mortality of a critical patient, making it essential to restore spontaneous ventilation as soon as possible. However, withdrawing a patient from mechanical ventilatory support may be more difficult than maintaining it, since extubation failure has been reported very often in previous investigations. For these patients, the nursing diagnosis of "Dysfunctional ventilatory weaning response" is established. However, despite being accepted by NANDA I for about 25 years, this diagnosis is not supported by scientific evidence and its defining characteristics and related factors are not yet determined in terms of relevance. This study aimed to validate clinically the nursing diagnosis "Dysfunctional ventilatory weaning response" in adult patients admitted to Intensive Care Units of Belo Horizonte, Minas Gerais. This is a two-step study integrative literature review and clinical validation. In the first stage, from an integrative review, clinical indicators were identified to determine the failure of ventilatory weaning and factors related to the development of this problem present in the literature. In the second stage, the incidence of this diagnosis was estimated in the population, in addition to the clinical indicators of determination of failure of ventilatory weaning and its related factors. A concurrent cohort study, conducted over a 12-month period, was conducted with 93 patients admitted to four intensive care units at two general and teaching hospitals. The association between factors related to the occurrence of "Dysfunctional ventilatory weaning response" was verified from bivariate analysis. The extraction of the predictive model for the problem was performed using multivariate logistic regression analysis. The clinical indicators of "Dysfu...
Asunto(s)
Palabras clave
Texto completo: 1 Bases de datos: BDENF Asunto principal: Diagnóstico de Enfermería / Desconexión del Ventilador / Factores de Riesgo Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: Pt Año: 2017 Tipo del documento: Thesis
Texto completo: 1 Bases de datos: BDENF Asunto principal: Diagnóstico de Enfermería / Desconexión del Ventilador / Factores de Riesgo Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: Pt Año: 2017 Tipo del documento: Thesis