Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Filtros aplicados
Intervalo de ano de publicação
1.
Braz. dent. sci ; 22(1): 31-38, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-986769

RESUMO

Objective: To evaluate the effect of Polyethylene Terephthalate (PET) tongue scraper on the volatile sulfur compound (VSC) levels. Material and Methods: A randomized, controlled, parallel design was used in this study. Out of the 48 volunteers from Dentistry Department of the Federal University of Sergipe, 40 subjects who met the inclusion criteria were randomly divided into 4 groups (n=10): G1 (control), rinsing of distilled water solution (WS); G2, WS and tongue coating removal (TCR) with toothbrush; G3, WS and TCR with a commercial tongue scraper; and G4, WS and TCR with PET tongue scraper. PET bottles were cut with a rectangular shape (1.0 cm wide x 20 cm long) to obtain PET tongue scraper. The VSC measurements were performed before (T0) and immediately after (T1) each therapy by portable sulfide monitor. Data (ppb) were submitted to Wilcoxon test (α=0.05). The differences between T0 and T1 were calculated and percentage values were assigned. Data (percentage) were submitted to ANOVA and Tukey test (α=0.05). Results: All 40 selected subjects completed the study. All groups reduced significantly the VSC levels after therapy (P<0.01). ANOVA indicated a significant difference among groups (P<0.001). The Tukey test showed that G1 (reduction of 21%) was similar to G2 (31%); G2 was similar to G3 (42%) and different from G4 (52%); G3 and G4 were similar. Conclusion: PET tongue scraper was similar to commercial tongue scraper and provided higher reductions of VSC levels than the toothbrush. (AU)


Objetivo: Avaliar o efeito do raspador de língua de polietilenotereftalato (PET) nos níveis de compostos sulfurados voláteis (CSVs). Material e Métodos: Um desenho paralelo, controlado e randomizado foi empregado neste estudo. Dos 48 voluntários do Departamento de Odontologia da Universidade Federal de Sergipe, 40 atenderam ao critério de inclusão e foram distribuídos aleatoriamente em 4 grupos (n=10): G1 (controle), bochecho com solução de água destilada (SA); G2, SA e remoção da saburra lingual (RSL) com escova dental; G3, SA e RSL com um raspador de língua comercial; e G4, SA e RSL com raspador de língua PET. Garrafas PET foram recortadas com uma forma retangular (1,0 cm de largura x 20 cm de comprimento) para obtenção dos raspadores de língua PET. As mensurações de CSVs foram realizadas antes (T0) e imediatamente após (T1) cada terapia usando um monitor portátil de enxofre. Os dados (ppb) foram submetidos ao teste de Wilcoxon (α=0,05). As diferenças entre T0 e T1 foram calculadas e transformadas em valores percentuais de redução. Os dados (percentuais) foram submetidos à ANOVA e ao teste de Tukey (α=0,05). Resultados: Todos os 40 indivíduos selecionados completaram o estudo. Em todos os grupos houve redução significante dos níveis de CSVs após terapia (P<0,01). ANOVA indicou uma diferença significante entre grupos (PP<0,001). O teste de Tukey mostrou que G1 (redução de 21%) foi semelhante a G2 (31%); G2 foi semelhante a G3 (42%) e diferente de G4 (52%); G3 e G4 foram semelhantes. Conclusão: O raspador de língua PET foi semelhante ao raspador de língua comercial e proporcionou maiores reduções de CSVs do que a escova dental. (AU)


Assuntos
Compostos de Enxofre , Língua , Polietilenotereftalatos , Halitose
2.
Braz. dent. sci ; 21(4): 445-450, 2018. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-966307

RESUMO

Objective: Evaluate the bond strength of resin cements to new materials for application in intraradicular posts. Material and Methods: Five materials were evaluated: fiberglass, PET, polyethylene, polyacetal and PTFE. Two commercial resin cements (Rely X U200 and Rely X Arc) were applied on the test specimens of the materials (9x3mm) and the bonding was evaluated through the shear bond strength test, where the chisel operated with a load of 1kN and a velocity of 0.5mm/min at the cement/material interface. The data were analyzed by the Shapiro-Wilk test, followed by the two-way analysis of variance, performed with the Bonferroni post-test (α=0.05). Results: The glass fiber was statistically different from all evaluated materials (p0.05). Comparing the two cements, a statistical difference was found between Rely X U200 and Arc only for the glass fiber (p=0). Conclusion: PET, polyethylene, polyacetal and PTFE exhibited reduced bond strength compared to the glass fiber (AU)


Objetivo: Avaliar a resistência de união de cimentos resinosos a novos materiais para aplicação em pinos intrarradiculares. Material e método: Foram avaliados cinco materiais: fibra de vidro, PET, polietileno, poliacetal e PTFE. Dois cimentos resinosos comerciais (Rely X U200 e Rely X Arc) foram aplicados sobre os corpos de prova dos materias (9x3mm) e a resistência de união foi avaliada através do teste de cisalhamento, onde o cinzel atuou com carga de 1kN e velocidade de 0,5mm/min na interface cimento/material. Verificada a normalidade dos dados através do teste Shapiro-Wilk, foi realizada a análise de variância de dois fatores com pós-teste de Bonferroni (α=0,05). Resultados: a fibra de vidro foi diferente estatisticamtente de todos os materiais avaliados (p0,05). Comparando-se os dois cimentos, foi encontrada diferença estatística entre o Rely X U200 e Arc apenas para a fibra de vidro (p=0). Conclusão: PET, polietileno, poliacetal e PTFE apresentaram resistência de união reduzida comparando-se à fibra de vidro. (AU)


Assuntos
Politetrafluoretileno , Polietilenotereftalatos , Cimentos de Resina
3.
An. Fac. Odontol. Univ. Fed. Pernamb ; 11(1/2): 65-8, 2001. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-849810

RESUMO

Este trabalho objetiva demonstrar como o P.E.T. (Polietileno Tereftalato) pode ser utilizado como estrutura na construção de Aparelhos Ortodônticos Removíveis, reduzindo o volume de acrílico e aço, transferindo o corpo da placa para a vestibular dos dentes posteriores, permitindo a total liberação da área lingual para as funções de deglutição e fonação, tornando o seu uso menos perceptível, portanto mais constante


Assuntos
Aparelhos Ortodônticos Removíveis , Polietilenotereftalatos , Aço , Desenho de Aparelho Ortodôntico , Ortodontia/instrumentação
4.
J. bras. ortodon. ortop. facial ; 3(14): 33-7, mar.-abr. 1998. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-271569

RESUMO

Este trabalho objetiva demostrar como o P.E.T. (Polietileno Tereftalato) pode ser utilizado como estrutura na construçäo de placas de contençäo removíveis, reduzindo o volume de acrílico e aço transferindo o corpo da placa para a vestibular dos dentes posteriores, permitindo a total liberaçäo da área lingual para as funçöes de deglutiçäo e fonaçäo, tornando o seu uso menos perceptível, portanto mais constante


Assuntos
Humanos , Contenções Ortodônticas , Polietilenotereftalatos , Aparelhos Ortodônticos Removíveis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...