Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 734
Filtrar
1.
Pesqui. bras. odontopediatria clín. integr ; 23: e210147, 2023. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1431045

RESUMO

Abstract Objective: To determine the effect of ozonated water on the color stability of denture tooth and denture bases. Material and Methods: Thirty denture base discs consisting of 15 Acropars and 15 ProBase Hot specimens with the dimensions of 40 × 5 mm were prepared. Fifteen denture teeth in shade A1 (Ivoclar Vivadent, Schaan, Liechtenstein) were mounted in a specific acrylic jig. All specimens were immersed in three solutions (1% sodium hypochlorite, ozonated water, and distilled water) for four months (one year of clinical use). Color measurements were done with a spectrophotometer and assessed using the CIE L*a*b* colorimetric system (0, 4, 8, 12, and 16 weeks). Data were analyzed using the three-way ANOVA and Tukey test (α=0.05). Results: Tukey's post hoc test revealed a significant change in color in the Acropars denture base for the distilled water group compared to the ozonated water and 1% hypochlorite (p<0.05). Regarding the ProBase Hot denture base, significantly less color change was observed in the 1% hypochlorite group compared to the ozonated water and distilled water (p≤0.001). For the denture teeth, significantly less color change was seen in the distilled water group than in the ozonated water (p=0.015) and 1% hypochlorite (p<0.05) groups. Conclusion: The color change of denture bases and denture tooth in ozonated water are acceptable. Ozonated water can be considered a good disinfectant for cleaning dentures.


Assuntos
Ozônio/uso terapêutico , Cor , Polimento Dentário , Prótese Total , Resinas Acrílicas , Água Destilada , Análise de Variância , Higienizadores de Dentadura/efeitos adversos , Polimerização
2.
Braz. dent. sci ; 26(4): 1-7, 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1523154

RESUMO

Objective: The study aimed to develop a cell phone application entitled: "Total Prosthesis Manual ­ Rehabilitating smiles", as an auxiliary teaching tool for teachers and students through digital technology, with a smartphone. Material and Methods: The tool was structured on the "Application Factory website", which allows the creation of mobile applications in different formats, with broad and interactive features on IOS and Android platforms. The expository format of the content is in slide format, containing descriptive theory and images about the stages of making a complete prosthesis; from necessary materials, photos and descriptive guidance of the steps. Results: The application is a complementary teaching resource to assist undergraduate and postgraduate students and professionals working in the area of complete prosthetics. The theoretical and practical content selected for the application covered all stages of understanding, development and possible complications associated with the manufacture of a complete bimaxillary prosthesis, from planning, impressions, models, orientation plans, tooth assembly, adaptations and delivery. Conclusion: The application provided a low-cost, expandable and easy-to-use teaching resource for teaching complete dentures. It is essential to develop various analyzes such as user experience tests, application effectiveness, development of new technologies and improvement of techniques, so that their potential for enriching learning in complete dentures and dentistry in general can be verified.(AU)


Objetivo: O estudo teve como objetivo desenvolver um aplicativo de celular intitulado: "Manual de Prótese Total ­ Reabilitando sorrisos", como uma ferramenta didática auxiliar para professores e alunos por meio da tecnologia digital, com smartphone. Material e Métodos: A ferramenta foi estruturada no "site da Fábrica de Aplicativos", que permite a criação de aplicativos móveis em diversos formatos, com recursos amplos e interativos nas plataformas IOS e Android. A modalidade expositiva do conteúdo é em formato de slides, contendo teoria descritiva e imagens sobre as etapas de confecção de uma prótese total; a partir de materiais necessários, fotos e orientação descritiva das etapas. Resultados: O aplicativo é um recurso didático complementar para auxiliar estudantes de graduação, pós-graduação e profissionais que atuam na área de prótese total. O conteúdo teórico e prático selecionado para a aplicação visou todas as etapas de compreensão, desenvolvimento e possíveis complicações associadas à confecção de uma prótese total bimaxilar, desde o planejamento, moldagens, maquetes, planos de orientação, montagem dos dentes, adaptações e entrega. Conclusão: O aplicativo trouxe um recurso didático de baixo custo, expansível e fácil de usar para o ensino de próteses totais. É fundamental desenvolver diversas análises como testes de experiência do usuário, eficácia de aplicação, desenvolvimento de novas tecnologias e aprimoramento de técnicas, de forma que possa ser verificado seu potencial de enriquecimento do aprendizado em prótese total e odontologia em geral(AU)


Assuntos
Humanos , Tecnologia Educacional , Prótese Total , Educação em Odontologia , Aplicativos Móveis , Educação a Distância , Odontólogos/educação
3.
Rev. Odontol. Araçatuba (Impr.) ; 43(3): 54-60, set.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1381314

RESUMO

The aim of this study is to report a clinical case of a patient with Cushing's syndrome, low self-esteem and need for oral rehabilitation. A 50-year-old female patient with hypercortisolism sought care at School of Dentistry of the Federal University of Minas Gerais. During anamnesis, the patient reported painful symptoms and mobility of the upper and lower teeth. On clinical examination, absence of many teeth were observed, periodontal disease and caries lesions. After discussion of the case, the planning involved the extraction of all teeth, and the preparation of Maxillary Immediate Complete Dentures (ICD's) and Immediate Mandibular Implant-retained Overdenture (IMIO). The treatment proposed allowed the restored aesthetics, phonetics and chewing(AU)


O objetivo desse estudo é relatar um caso clínico de uma paciente com síndrome de Cushing, baixa autoestima e necessidade de reabilitação oral. Paciente do sexo feminino, 50 anos de idade e com hipercortisolismo, procurou atendimento na Faculdade de Odontologia da Universidade Federal de Minas Gerais. Durante a anamnese, a paciente relatou sintomas dolorosos e mobilidade dos dentes superiores e inferiores. No exame clínico, foi observada a ausência de muitos dentes, doença periodontal e lesões cariosas. Após a discussão do caso, o planejamento envolveu a extração de todos os dentes, e o preparo de Prótese Total Imediata maxilar (PTI), e Overdenture Implantorretida Imediata mandibular. O tratamento proposto permitiu que restaurasse a estética, fonética e mastigação(AU)


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Síndrome de Cushing , Prótese Total Imediata , Doenças Periodontais , Extração Dentária , Cárie Dentária , Prótese Total , Revestimento de Dentadura , Estética Dentária
4.
Braz. j. oral sci ; 21: e225686, jan.-dez. 2022. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1366509

RESUMO

Aim: Tooth loss is very prevalent in Brazil, reflecting high demand for dental services, especially those related to oral rehabilitation. This study aimed to assess the quality of life in total edentulous patients rehabilitated with implants and fixed prosthesis. Methods: Thirty-two patients were evaluated before and after rehabilitation with dental implants and fixed prosthesis using the OHIP-14 questionnaire and the Visual Analogue Scale (VAS) after 6 months follow-up. Results:OHIP-14 revealed a significant improvement after treatment in all seven parameters and in the global score (P < 0.001). VAS presented positive results related to patient satisfaction regarding oral rehabilitation, except for the hygiene of the fixed dentures. Conclusion: At the end of this study, OHIP-14 scores decreased by 50% in most of the questions raised, and VAS presented positive results, except for hygiene of the fixed dentures, presenting an improvement in the quality of life of total edentulous patients after rehabilitation with implants and fixed prosthesis


Assuntos
Humanos , Masculino , Feminino , Qualidade de Vida , Implantes Dentários , Boca Edêntula/reabilitação , Satisfação do Paciente , Prótese Total
5.
Natal; s.n; 9 nov 2022. 158 p. tab, ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1532385

RESUMO

Este estudo objetivou identificar os fatores que influenciam na decisão de substituir uma prótese total convencional mandibular pelo tratamento com implantes dentários, assim como avaliar a satisfação, qualidade de vida e performance mastigatória (PM) após reabilitação com sobredentaduras com implante único (SIU) em pacientes adaptados e não-adaptados a prótese total convencional (PT) mandibular. Inicialmente, foi realizado um estudo transversal com 117 usuários de PTs bimaxilares, avaliados quanto aos desfechos relacionados à prótese (número de PTs mandibulares usadas previamente, tempo de uso e profissional que confeccionou a prótese atual, e quanto ao uso regular ou não da prótese mandibular) e aspectos centrados no paciente (período de edentulismo mandibular, altura óssea mandibular e interesse do paciente em se submeter a terapia com implantes). Do total da amostra, 78 pacientes manifestaram interesse na terapia implantossuportada, e desses apenas 22 foram selecionados e reabilitados com novas PTs bimaxilares. Após critérios de elegibilidade, foram alocados após pareamento em 2 grupos: adaptados à prótese mandibular (Grupo PTA - "adaptados à PT mandibular", n:10) e não adaptados (Grupo PTN - "não adaptados à PT mandibular", n:12). Em cada paciente, foi instalado um único implante na linha média e após o período de osseointegração as próteses mandibulares foram convertidas em sobredentaduras. O desempenho mastigatório foi avaliado pelo método das tamises, a altura óssea mandibular por medição em radiografia panorâmica, satisfação por escala quantitativa com questionário validado e o impacto da saúde oral na qualidade de vida pelo questionário OHIP-Edent-19. O teste Qui-quadrado foi utilizado para análise dos dados e as razões de prevalência ajustadas por meio da regressão multivariada de Poisson no primeiro estudo; para o segundo, a análise estatística em cada grupo e entre grupos foi baseada nos testes não-paramétricos de Wilcoxon e Mann-Whitney. O intervalo de confiança para os testes foi de 95%. A amostra foi predominantemente do sexo feminino, com 66,7% (n=78) dos participantes interessados em PT mandibular implantossuportada e com idade média de 65,68±6,38 anos. A PM não influenciou a escolha pela reabilitação com implantes. A preferência pela PT implantossuportada mandibular foi associada significativamente com maior experiência prévia com PT mandibular (p=0,021) e à insatisfação quanto à retenção (p=0,005). Após a intervenção com implante, todos os pacientes não adaptados passaram a condição de adaptados. Não houve diferença entre PTA e PTN para OHIP-Edent (p=0,276) e PM (p=0,222), a satisfação foi significativa apenas para o critério "conforto em arco inferior" (p=0,043). Para comparações pré e pós-tratamento com sobredentadura, a mediana do OHIP-Edent total diminuiu significativamente em ambos os grupos. Na comparação intragrupo, essa redução foi significativa em PTA apenas para a "limitação funcional" (p=0,026), e em PTN em quase todos os domínios, exceto "disfunção social" e "incapacidade" (p>0,05). Houve aumento estatisticamente significativo para a satisfação geral de 75,41 para 90,25 (p=0,012) em PTN e de 76,10 para 90,50 (p=0,007) em PTA. Os parâmetros "mastigação", "adaptação", "retenção" e "conforto" em arco inferior foram diferentes com significância em ambos os grupos, e "gustação", "fonação" e "dor" em arco inferior foram significativos apenas para o grupo não adaptado (p<0,05). Houve diferença significativa para PM em PTN (p=0,002) e PTA (p=0,047) ao se comparar tipo de reabilitação. Não houve correlação entre PM e OHIP antes e após a reabilitação (p>0,05). Pode-se concluir que a experiência prévia com PT mandibulares convencionais e a insatisfação com a retenção dessas, influenciam o interesse pela reabilitação com sobredentadura implantossuportada mandibular, assim como, a reabilitação com sobredentadura sobre implante único apresenta-se como alternativa aos pacientes não adaptados a PT convencional mandibular, auxiliando na aceitação do uso da prótese mandibular, assim como, comprovando efeito positivo na satisfação, qualidade de vida e performance mastigatória (AU).


This study aimed to identify the factors that influence the decision to replace a conventional mandibular complete denture by treatment with dental implants, as well as to evaluate satisfaction, quality of life and masticatory performance (MP) after rehabilitation with overdentures with a single implant in patients adapted and not adapted to conventional mandibular complete denture (CD). Initially, a cross-sectional study was carried out with 117 users of bimaxillaries CDs, who were evaluated for outcomes related to the denture (number of previous mandibular CDs, time of use and professional who made the current denture, and regarding regular use of the mandibular denture) and aspects centered patients (period of mandibular edentulism, mandibular bone height and the patient's willingness to undergo implant therapy). From the total sample, 78 patients expressed interest in implant-supported therapy, and of these, only 22 were selected and rehabilitated with new bimaxillary CDs. After eligibility criteria, they were allocated after pairing into 2 groups: adapted to mandibular prosthesis (PTA Group - "adapted to mandibular CD", n:10) and non-adapted (PTN Group - " not adapted to mandibular CD", n:12). In each patient, a single implant was installed in the midline and after the osseointegration period, the mandibular prostheses were converted into overdentures. Masticatory performance was evaluated by the sieve method, mandibular bone height by paranoid radiographic measurement, satisfaction by quantitative scale with a validated questionnaire and the impact of oral health on quality of life by the OHIP-Edent-19 questionnaire. The chi-square test was used for data analysis and the prevalence ratios adjusted by means of multivariate Poisson regression in the first study; on the second, the statistical analysis in each group and between groups was based on the non-parametric-Wilcoxon and Mann-Whitney tests. The confidence interval for the tests was 95%. The sample was composed predominantly by women, with 66.7% (n=78) of the participants interested in implantsupported mandibular CD, with mean age 65.68±6.38 years. MP was not influenced by the choice by dental implants rehabilitation. Preference for mandibular implant-supported CD was significantly associated with longer previous experience in mandibular CD (p=0.021) and with dissatisfaction regarding retention (p=0.005). After the implant intervention, all non-adapted patients became adapted. There was no difference between PTA and PTN for OHIP-Edent (p=0.276) and MP (p=0.222), satisfaction was significant only for the criteria "comfort in the lower arch" (p=0.043). For pre- and post-treatment comparisons with overdentures, the median total OHIP-Edent decreased significantly in both groups. In the intragroup comparison, this reduction was significant in PTA only for "functional limitation" (p=0.026), and in PTN in almost all domains, except "social dysfunction" and "disability" (p>0.05). There was a statistically significant increase in overall satisfaction from 75.41 to 90.25 (p=0.012) in PTN and from 76.10 to 90.50 (p=0.007) in PTA. The parameters "chewing", "adaptation", "retention" and "comfort" in the lower arch were significantly different in both groups, and "gustation", "phonation" and "pain" in the lower arch were significant only for the group not adapted (p<0.05). There was a significant difference for MP in PTN (p=0.002) and PTA (p=0.047) when comparing the type of rehabilitation. There was no correlation between MP and OHIP before and after rehabilitation (p>0.05). It can be concluded that the previous experience with conventional mandibular CD and the dissatisfaction with the retention of these, influence the rehabilitation with mandibular implant-supported overdenture, as well as the rehabilitation with overdenture on single implant presents itself as an alternative for patients not adapted to mandibular conventional CD, helping to accept the use of mandibular prosthesis, as well as proving a positive effect on satisfaction, quality of life and masticatory performance (AU).


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Qualidade de Vida , Prótese Total , Mastigação , Reabilitação Bucal , Estudos Transversais/métodos , Satisfação do Paciente , Estatísticas não Paramétricas , Implante de Prótese Mandibular , Implantação Dentária , Carga Imediata em Implante Dentário
6.
Natal; s.n; 21 out. 2022. 126 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1532447

RESUMO

Recursos digitais, como a manufatura subtrativa (fresagem CAD-CAM) e a manufatura aditiva (impressão 3D) podem promover significativos avanços, reduzindo o tempo e o custo de produção de próteses totais (PTs). Assim, este estudo objetiva investigar as características superficiais (rugosidade e ângulo de contato), propriedades mecânicas (resistência mini-flexural) e a adesão de biofilme sobre polímeros de PMMA pré-polimerizado para fresagem CAD-CAM e sobre resinas para impressão 3D utilizados na fabricação de bases de PTs, bem como propor um fluxo de trabalho inovador para abreviar e simplificar as etapas de confecção de PTs. Para a análise in vitro, foram fabricados um total de 60 discos e 40 barras distribuídas igualmente em quatro grupos: fresagem CAD-CAM (GF), impressão 3D (GI) e PMMA convencional termopolimerizado por ciclo longo (GCL) ou por energia de micro-ondas (GCM). A rugosidade foi determinada pelo valor de Ra; o ângulo de contato foi medido pelo método da gota séssil; o teste de resistência à mini-flexão foi obtido por teste de flexão de três pontos, enquanto o comportamento frente à formação de biofilme foi analisado através da adesão de biofilme de C. albicans. Os dados foram analisados por meio de estatística descritiva e analítica (α = 0,05). Os resultados mostraram que o GI apresentou a maior rugosidade superficial (Ra: 0,317 ± 0,151µm) e os menores valores de resistência à miniflexão (57,23 ± 9,07MPa) e o GF apresentou a menor adesão de biofilme de C. albicans (log UFC/mL: 3,74 ± 0,57) e maior média de resistência à mini-flexão (114,96 ± 16,23 MPa). Não houve diferença estatística entre o GF e os grupos convencionais para rugosidade, ângulo de contato e resistência à mini-flexão. A patente de inovação desenvolvida estabeleceu um novo fluxo de trabalho para confecção de próteses totais através de um protocolo de três consultas em que foram feitas as moldagens anatômicas na 1ª sessão, juntamente com o registro do suporte labial, plano oclusal e linhas de referência para subsidiar a montagem dos dentes superiores. Uma prótese-teste foi confeccionada por meio de procedimentos convencionais ou CAD-CAM e avaliada na 2ª consulta, permitindo observar o resultado estético, executar a moldagem funcional e realizar o registro da relação maxilo-mandibular, fornecendo referências precisas para a confecção da prótese inferior. Com base nos resultados da fase in vitro deste estudo, os corpos-de-prova obtidos a partir de disco para fresagem CAD-CAM apresentaram resistência flexural e propriedades superficiais semelhantes às resinas convencionais e mostraram um comportamento inibidor da adesão de C. albicans, enquanto os espécimes produzidos por impressão 3D exibiram a menor resistência à flexão e a maior rugosidade da superfície. O dispositivo inovador apresentado para a execução das etapas clínicas relacionadas à fabricação de PTs mostrou-se efetivo para abreviar e simplificar as técnicas disponíveis, apresentando confiabilidade e previsibilidade para produção de PTs em número de sessões reduzido (AU).


Digital features like subtractive and additive manufacturing can promote breakthroughs by reducing the time and cost of making complete dentures (CDs). Thus, this study aims to investigate surface characteristics (roughness and contact angle), mechanical properties (mini-flexural strength), and biofilm adhesion on computer-aided design/computer-aided manufacturing (CAD-CAM) PMMA polymer, and threedimensional (3D) printed resin for denture´s base fabrication as well as to propose an innovative workflow. For in vitro analysis, a total of 60 discs and 40 rectangular specimens were fabricated from one CAD-CAM pre-polymerized PMMA disc (GF), one 3D-printed (GI), and two conventional heat-polymerized (GCL and GCM) materials for denture base fabrication. Roughness was determined by the Ra value; the contact angle was measured by the sessile drop method; the mini-flexural strength test was a three-point bending test while the biofilm formation inhibition behavior was analyzed through C. albicans adhesion. The data were analyzed using descriptive and analytical statistics (α = 0.05). Results showed that GI specimens presented the highest surface roughness (Ra: 0.317 ± 0.151 µm) and lowest mini-flexural strength values (57.23 ± 9.07 MPa) and the GF showed the lowest C. albicans adhesion (log CFU/mL: 3.74 ± 0.57) and highest mini-flexural strength mean (114.96 ± 16.23 MPa). There was no statistical difference between GF and conventional groups for roughness, contact angle, and mini-flexural strength. In turn, the presented novel workflow for complete dentures fabrication reached a three appointments protocol in which preliminary impressions were made in the 1st session, all together to maxillary registration of lip support, occlusal plane, and reference lines for teeth arrangement. A trial denture was manufactured and evaluated by the 2nd appointment through conventional or CAD-CAM procedures, allowing esthetics evaluation, final impression, and maxillomandibular relationship record and providing precise references for final dentures fabrication. Based on the findings of this in vitro study, GF presented surface and mechanical properties similar to conventional resins and show improved behavior preventing C. albicans adhesion, while GI specimens exhibited the lowest flexural strength, and highest surface roughness. The proposed device for CD´s fabrication clinical procedures reached feasibility and by simplifying available techniques, this protocol could achieve reliability and predictability to produce complete dentures with reduced working time (AU).


Assuntos
Resinas Sintéticas , Desenho Assistido por Computador/instrumentação , Prótese Total/tendências , Tecnologia Digital , Técnicas In Vitro/métodos , Placa Dentária/prevenção & controle , Fluxo de Trabalho , Testes Mecânicos/métodos
7.
Rev. Odontol. Araçatuba (Impr.) ; 43(2): 49-54, maio-ago. 2022.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1362035

RESUMO

Overdenture é uma prótese total que se caracteriza por usar apoios retentivos para que aumente sua estabilidade e retenção na cavidade bucal, gerando assim menor desconforto ao paciente e melhor adaptação. A Prótese overdenture dentossuportada necessita de elementos dentais remanescentes com canais tratados endodonticamente e que possuam suporte periodontal adequado. O objetivo deste relato de caso clínico é expor a sequência de confecção de uma prótese overdenture dentossuportada maxilar associada a uma prótese total convencional mandibular, com os passos clínicos detalhados por meio de uma abordagem teórica e visual. Esse tipo de reabilitação favorece a adaptação do paciente à nova condição, visto que o uso de próteses totais convencionais pode causar certo desconforto ao paciente devido à falta de retenção e estabilidade. Essa manutenção dos dentes remanescentes favorece à manutenção óssea e a futura decisão do paciente em optar pela instalação de implantes dentários, podendo confeccionar próteses implantorretidas (overdentures) ou implantossuportadas (protocolo).O Paciente demonstrou-se satisfeito com o resultado estético e funcional após a instalação da prótese concretizando que o tratamento é viável(AU)


Overdenture is a denture that utilizing retentive supports for increase stability and retention in oral cavity. The tooth-supported overdenture require dental elements with root canal therapy and good periodontal support. The aim of this study is to report the confection of a maxillary tooth-supported overdenture associated with mandibular denture and your clinical steps. This rehabilitation promotes the patient's adaptation the new condition, since the use of conventional dentures may cause discomfort due to lack of retention and stability. The preservation of dental elements promotes bone maintenance and forthcoming decision of the patient in the installation of dental implants that can choose implantretained or implant-supported prosthesis. Patient was satisfied with aesthetic and functional result after installation of prosthesis(AU)


Assuntos
Humanos , Masculino , Retenção de Dentadura , Prótese Total , Revestimento de Dentadura , Retenção em Prótese Dentária , Prótese Dentária
8.
Araçatuba; s.n; 2022. 73 p. ilus, graf, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1435928

RESUMO

Objetivo: Avaliar se customizações da prótese total mandibular (reembasamento e restabelecimento da dimensão vertical de oclusão) influenciam na amplitude eletromiográfica dos músculos masseter e temporal, força máxima de mordida e qualidade de vida relacionada à saúde oral de indivíduos edêntulos. Materiais e métodos: Usuários de próteses totais que usavam o mesmo par de próteses por mais do que 5 anos foram incluídos (sem disfunção temporomandibular) (n=15). Avaliações de qualidade de vida (Oral Health Impact Profile for Edentulous ­ OHIP-EDENT), força máxima de mordida, e eletromiografia dos músculos masseter e temporal foram realizadas em 5 tempos diferentes (T1 ­ próteses antigas originais; T2 ­ após 18 dias de uso da prótese mandibular reembasada; T3 ­ após 18 dias do restabelecimento da dimensão vertical de oclusão; e T4 e T5 ­ 30 e 100 dias de uso de novas próteses totais. Resultados: Não houve diferenças significativas entre os pontos de tempo para todos os testes eletromiográficos e de força máxima de mordida. O OHIP-EDENT mostrou que o reembasamento pode contribuir para uma maior adaptação da prótese total mandibular e conforto do paciente (T2), em contrapartida T3 foi associado com o desconforto do paciente (p<0.05). Conclusão: Baseado na avaliação de qualidade de vida relacionada à saúde oral, o reembasamento da prótese total mandibular ocasionou um aumento do conforto mastigatório para os pacientes, e o restabelecimento prévio da dimensão vertical de oclusão causou um desconforto para os pacientes. A amplitude eletromiográfica mostrou que as customizações realizadas neste estudo não aumentaram ou diminuíram o esforço mastigatório significativamente. Além disso, todos os valores de força máxima de mordida observados estavam dentro do clinicamente aceitável(AU)


Objective: To evaluate whether customizations of mandibular complete dentures (relining and restoration of the vertical dimension of occlusion) influence the electromyographic amplitude of the masseter and temporal muscles, maximum bite force and oral health-related quality of life of edentulous individuals. Materials and methods: Complete denture wearers who wore the same pair of dentures for more than 5 years were included (without temporomandibular dysfunction) (n=15). Assessments of quality of life (Oral Health Impact Profile for Edentulous ­ OHIP-EDENT), maximum bite force, and electromyography of the masseter and temporal muscles were performed at 5 different times (T1 - original old dentures; T2 - after 18 days of wearing relined mandibular denture; T3 - after 18 days of restoration of the vertical dimension of occlusion; and T4 and T5 - 30 and 100 days of wearing new complete dentures. Results: There were no significant differences between the time points for all electromyographic and maximum bite force tests. The OHIP-EDENT showed that relining can contribute to greater adaptation of the mandibular denture and patient comfort (T2), in contrast, T3 was associated with patient discomfort (p<0.05). Conclusion: Based on the assessment of quality of life related to oral health, the reline of the mandibular complete denture caused an increase in masticatory comfort for the patients, and the previous definitive restoration of the vertical dimension of occlusion caused discomfort for patients. The electromyographic amplitude showed that the customizations performed in this study did not significantly increase or decrease masticatory effort. In addition, all observed maximum bite force values were within the clinically acceptable range(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Qualidade de Vida , Força de Mordida , Arcada Edêntula , Prótese Total , Músculos da Mastigação , Dimensão Vertical , Saúde Bucal , Reembasamento de Dentadura , Eletromiografia , Reabilitação Bucal
9.
Rev. odontol. UNESP (Online) ; 51: e20220015, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1409936

RESUMO

Introduction Temporomandibular disorder (TMD) involves the mastication and temporomandibular articulation muscles. Completely toothless patients with prostheses should be thoroughly assessed since edentulism causes damage that can lead to TMD onset. Objective This study aims to assess the effect of the technical quality of total prostheses (TPs) on TMD occurrence in patients with bimaxillary TPs. Material and method 154 patients responded to a questionnaire to obtain personal data, information regarding prostheses, anamnestic index for TMD, and the prosthesis quality index. Result Of the 154 patients examined, 64 (41.6%) had no TMD, 61 (39.6%) had mild TMD, 23 (14.9%) moderate, and only 6 (3.9%) showed severe TMD. As for the quality of total prosthesis, 78 (50.6%) completely toothless individuals had satisfactory TPs while 76 (49.4) presented unsatisfactory prostheses. Regarding the time using total prosthesis, around 50% of individuals with up to 10 years use presented some degree of TMD and 70% of individuals with over 10 years presented TMD. Conclusion Considering the methodology used and the population studied, we conclude that the quality of the TPs did not influence the incidence of TMD.


Introdução A disfunção temporomandibular (DTM) é uma desordem que envolve os músculos da mastigação e da articulação temporomandibular. Pacientes desdentados totais e que utilizam protéses requerem uma avaliação criteriosa, já que o edentulismo leva a prejuízos que podem contribuir para o aparecimento de DTM. Objetivo O objetivo deste presente estudo foi avaliar o efeito da qualidade técnica das próteses totais (PTs) na incidência de DTM em pacientes portadores de PTs bi-maxilares. Material e método Foi aplicado um questionário a 154 pacientes contendo os dados pessoais, o histórico das próteses, o índice anamnésico para DTM e o índice de qualidade de prótese. Resultado Dos 154 pacientes examinados, 64 (41,6%) estavam livres de DTM, 61 (39,6%) possuíam DTM leve, 23 (14,9%), moderada e apenas 6 (3,9%) mostravam DTM severa. Quanto à qualidade da prótese total, 78 (50,6%) desdentados totais portavam PTs satisfatórias e 76 (49,4) estavam com próteses insatisfatórias. Quanto ao tempo de uso da prótese total, cerca de 50% dos indivíduos com até 10 anos de uso apresentaram algum grau de DTM e 70% dos indivíduos com mais de 10 anos acusaram a presença de DTM. Conclusão Considerando-se a metodologia empregada e a população estudada, pôde-se concluir que a qualidade das PTs não influenciou na presença de DTM.


Assuntos
Humanos , Síndrome da Disfunção da Articulação Temporomandibular , Distribuição de Qui-Quadrado , Inquéritos e Questionários , Boca Edêntula , Prótese Total
10.
Braz. dent. sci ; 25(1): 1-11, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354726

RESUMO

Objective: To compare the three different methods of complete denture fabrication assessing patient satisfaction and retention after insertion for six months' follow-up period. Material and Methods: The study was conducted in the Prosthodontic Department where a total of forty-eight patients were recruited from the outpatient clinics fulfilling the inclusion criteria. This study was designed as a randomized controlled clinical trial. All patients followed the steps of complete denture construction till jaw relation record. Then, all eligible patients were randomized to intervention and control groups. For intervention groups digital scanning, designing, manufacturing of complete dentures was done; 3D printing for first and milling for second intervention. For the comparator group, complete dentures were manufactured the conventional way. After 2 weeks of delivery of the dentures, patients received a patient satisfaction questionnaire, retention was measured by retention force gauge. Both readings were also recorded after 3 months and at 6 months. The mean and standard deviation values were calculated for each group in each test. The significance level was set at P≤ 0.05. Results: No statistical difference was found in terms of patient satisfaction and retention between the three groups at different time intervals. Conclusion: The manufacturing technique seemed to have no influence on patient satisfaction and retention with milled showing the least results.(AU)


Objetivo: Comparar três métodos diferentes de fabricação de prótese total avaliando a satisfação do paciente e a retenção após a inserção por um período de acompanhamento de seis meses. Material e Métodos: O estudo foi conduzido no departamento de Prótese onde um total de quarenta e oito pacientes foram recrutados das clínicas ambulatoriais atendendo os critérios de inclusão. Este estudo foi designado como um ensaio clínico randomizado controlado. Todos os pacientes seguiram as mesmas etapas de confecção de prótese total até o registro da relação maxilo-mandibular. Então, todos os pacientes qualificados foram divididos de forma aleatória nos grupos de intervenção e grupo controle. Para os grupos de intervenção foram realizados escaneamento digital, projeto e fabricação de próteses totais; Impressão 3D para o primeiro e fresagem para o segundo grupo de intervenção. Para o grupo de comparação, próteses totais foram feitas com o método convencional. Depois de 2 semanas após a entrega das próteses os pacientes receberam um questionário de satisfação e a retenção foi mensurada com um medidor de força de retenção. Ambas as leituras também foram registradas após 3 e 6 meses. Os valores de média e desvio padrão foram calculados para cada grupo em cada teste. O nível de significância foi estabelecido em P ≤ 0,05. Resultados: Nenhuma diferença estatística foi encontrada em termos de satisfação do paciente e retenção entre os três grupos em diferentes intervalos de tempo. Conclusão: A técnica de fabricação pareceu não ter influência na satisfação do paciente e retenção da prótese, com o grupo fresado apresentando o mínimo de resultados.(AU)


Assuntos
Satisfação do Paciente , Retenção em Prótese Dentária , Desenho Assistido por Computador , Prótese Total , Impressão Tridimensional
11.
Pesqui. bras. odontopediatria clín. integr ; 22: e210131, 2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1365225

RESUMO

Abstract Objective: To analyze and compare changes of quality of life parameter among dental patients rehabilitated by the implant-supported overdentures with different attachment systems. Material and Methods: Forty-eight patients were recruited as a study cohort. The implant placement procedure was based on the results obtained by CBCT scanning and individualized surgical templates manufactured for correct implant placement. Each individual received two k3Pro Implants (Sure Type with 4.0 or 4.5 mm in diameter) at the intraforaminal area due to standard protocol of implantation provided by the manufacturer under local anesthesia. All patients were distributed between two groups based on the fact of using either Locator- or ball-attachments. Rank correlation was measured using Spearman correlation coefficient, while linear correlation was evaluated by Pearson correlation coefficient. Results: No statistically meaningful differences were noted regarding patients' distribution among groups considering age (p>0.05) and gender (p>0.05). Provided patient-level analysis demonstrated that increase of conventional full denture service time was positively correlated with escalation of OHIP-EDENT scores. The most prominent inter-correspondences were noted specifically between longevity of denture service and elevation of scores within "Functional limitation" (r=0.61; p<0.05), "Physical pain" (r=0.51; p<0.05) and "Physical disability" (r=0.57; p<0.05) subdomains. No statistically argumented regressions were noted between increase tendency of OHIP-EDENT scores and gender (p>0.05) or age (p>0.05) parameters. Conclusion: Significant improvements of quality of life measured with OHIP-EDENT were noted for both types of attachments compared to the pre-treatment situation independently of additionally provided surface electromyography-based alignment.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Qualidade de Vida , Prótese Dentária Fixada por Implante/instrumentação , Eletromiografia/instrumentação , Músculos da Mastigação , Ucrânia , Inquéritos e Questionários , Análise de Regressão , Estudos de Coortes , Estatísticas não Paramétricas , Ajuste Oclusal , Adaptação a Desastres , Implantação Dentária , Prótese Total , Revestimento de Dentadura
12.
Araçatuba; s.n; 2022. 79 p. tab, ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1442671

RESUMO

O objetivo desse estudo foi investigar as propriedades de superfície, estabilidade de cor e propriedades mecânicas de resinas acrílicas para base de dentadura do método convencional, processada por micro-ondas, fresada e impressa 3D diante de diferentes tempos de envelhecimento e imersão em bebidas corantes. Além disso, realizar uma revisão sistemática para avaliar e comparar, através de estudos de ensaios clínicos, próteses totais fabricadas pelo método CAD/CAM com fabricadas convencionalmente, em termos de tempo clínico, manutenção, retenção, estabilidade, eficácia mastigatória, satisfação e qualidade de vida. Um total de 480 amostras redondas (10 × 3,3 ± 0,03 mm) foram confeccionadas para avaliação das propriedades de superfície e estabilidade de cor, divididas entre os quatro grupos principais de resinas e subdivididas em quatro tempos de análise (T0, T1, T2 e T3) e bebidas corantes (água, café, vinho e refrigerante cola), resultando um n = 10 para cada subgrupo. Um total de 160 amostras retangulares (64 × 10 × 3,3 ± 0,03 mm) foram confeccionadas para avaliação das propriedades mecânicas, divididas entre os quatro grupos principais de resinas e subdivididas em quatro tempos de análise (T0, T1, T2 e T3), resultando um n = 10 para cada subgrupo. A revisão sistemática seguiu os Itens de Relatório Preferenciais para Revisões Sistemáticas e Meta-Análises (PRISMA) e foi registrada no Registro Prospectivo Internacional de Revisões Sistemáticas (PROSPERO) (CRD42022296907). A busca eletrônica foi realizada nas bases de dados PubMed/MEDLINE, Web of Science e Scopus até dezembro de 2021. A questão formulada para população, intervenção, comparação e resultado (PICO) foi "Pacientes reabilitados com próteses totais com tecnologia CAD/CAM apresentam parâmetros clínicos semelhantes aos pacientes reabilitados com próteses totais convencionais?". A resina fresada apresentou os melhores resultados das propriedades de superfície diante do efeito do envelhecimento, enquanto que a resina impressa 3D apresentou resultados semelhantes as resinas tradicionais. A resina de Impressão 3D apresentou não ter propriedades ópticas adequadas diante do efeito do envelhecimento, enquanto que a resina fresada apresentou as melhores propriedades. As bebidas corantes não alteraram as propriedades de superfície das resinas, entretanto afetaram suas propriedades ópticas, principalmente a resina de impressão 3D e a processada por micro-ondas. A resina de dentadura fresada CAD/CAM apresentou propriedades mecânicas semelhantes as resinas tradicionais, enquanto que a impressa 3D não apresentou propriedades mecânicas adequadas para uso clínico à longo prazo. As próteses do método de fresagem apresentaram melhor desempenho clínico que as próteses convencionais, em termos de qualidade de vida, satisfação, retenção, estabilidade, tempo clínico e custo, enquanto que as de impressão 3D não apresentaram diferenças. Ambos os métodos do CAD/CAM apresentaram não haver diferenças da eficácia mastigatória em relação as próteses convencionais(AU)


The objective of this study was to investigate the surface properties, color stability and mechanical properties of acrylic resins for denture base of the conventional method, processed by microwave, milled and 3D printed in face of different aging times and immersion in coloring drinks. In addition, carry out a systematic review to evaluate and compare, through clinical trial studies, complete dentures manufactured by the CAD/CAM method with those manufactured conventionally, in terms of clinical time, maintenance, retention, stability, masticatory efficiency, satisfaction and quality of life. A total of 480 round samples (10 × 3.3 ± 0.03 mm) were made to evaluate surface properties and color stability, divided among the four main groups of resins and subdivided into four analysis times (T0, T1, T2 and T3) and coloring drinks (water, coffee, wine and cola), resulting in n = 10 for each subgroup. A total of 160 rectangular samples (64 × 10 × 3.3 ± 0.03 mm) were prepared to evaluate the mechanical properties, divided among the four main groups of resins and subdivided into four analysis times (T0, T1, T2 and T3), resulting in n = 10 for each subgroup. The systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and was registered in the International Prospective Registry of Systematic Reviews (PROSPERO) (CRD42022296907). The electronic search was performed in the PubMed/MEDLINE, Web of Science and Scopus databases until December 2021. The question formulated for population, intervention, comparison and result (PICO) was "Patients rehabilitated with complete dentures with CAD/CAM technology present clinical parameters similar to patients rehabilitated with conventional complete dentures?". The milled resin presented the best results of surface properties in the face of aging effect, while the 3D printed resin presented similar results to traditional resins. The 3D Printing resin did not have adequate optical properties due to the aging effect, while the milled resin showed the best properties. Coloring drinks do not change the surface properties of resins, but optical printing solutions, mainly 3D printing resin and microwave-processed resin. The CAD/CAM milled denture resin presented mechanical properties similar to traditional resins, while the 3D printed denture resin did not present adequate mechanical properties for long-term clinical use. The milling method prostheses showed better clinical performance than conventional prostheses, in terms of quality of life, satisfaction, retention, stability, clinical time and cost, while the 3D printing prostheses showed no differences. Both CAD/CAM methods showed no differences in masticatory efficiency in relation to conventional prostheses(AU)


Assuntos
Bases de Dentadura , Fatores de Tempo , Cor , Polimetil Metacrilato , Prótese Total , Resinas , Fenômenos Mecânicos
13.
Braz. dent. sci ; 25(3): 1-10, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1372941

RESUMO

Objective: To evaluate and compare prosthesis and implant survival in case of interim fixed complete dentures reinforced with fiber resin frameworks versus those that were not reinforced with any framework in case of immediately loaded full arch restorations in completely edentulous patients. Material and Methods: Thirty completely edentulous patients were randomly allocated into two parallel arm groups. Non-reinforced control group in which patients received non-reinforced all-on-four immediately loaded fixed complete denture and Fiber reinforced group in which patients received all-on-four fixed complete denture supported with glass-fiber reinforced resin framework. Prosthesis and implant survival were clinically evaluated after 4 months follow up period. Results: A statistically significant difference for prosthesis (p = 0.032) and implant survival (p = 0.031) was found between both groups. The fiber-reinforced group showed 100% prosthesis survival and 95% implant survival. On the other hand, the non-reinforced group showed 73.3% prosthesis survival and 81.1% implant survival. Conclusion: Based on the findings of this study, it can be concluded that strengthening the fixed full arch restorations with fiber reinforced frameworks can help overcoming the problem of interim prosthesis fracture during the osseointegration period when used for immediate loading in completely edentulous patients. It can also improve the survival of the immediately loaded implants. (AU)


Objetivo : Avaliar e comparar a sobrevivência de próteses e implantes no caso de próteses totais fixas provisórias reforçadas com estruturas de resina de fibra versus aquelas que não foram reforçadas com nenhuma estrutura no caso de restaurações de arcada completa com carga imediata em pacientes completamente desdentados. Material e Métodos : Trinta pacientes completamente desdentados foram alocados aleatoriamente em dois grupos de braços paralelos. Grupo controle não reforçado, no qual os pacientes receberam prótese total fixa (all-on-four) não reforçada, com carga imediata e grupo reforçado com fibra, no qual os pacientes receberam prótese total fixa (all-on-four), suportada com estrutura de resina reforçada com fibra de vidro. A sobrevivência da prótese e do implante foi avaliada clinicamente após 4 meses de acompanhamento. Resultados : Foi encontrada diferença estatisticamente significante para prótese (p=0,032) e sobrevivência do implante (p=0,031) entre os dois grupos. O grupo reforçado com fibra apresentou 100% de sobrevivência da prótese e 95% de sobrevivência do implante. Por outro lado, o grupo não reforçado apresentou 73,3% de sobrevivência da prótese e 81,1% de sobrevivência do implante. Conclusão: Com base nos achados deste estudo, pode-se concluir que o fortalecimento das restaurações fixas de arcada completa com estruturas reforçadas com fibras pode ajudar a superar o problema da fratura da prótese provisória durante o período de osteointegração quando usada para carga imediata em pacientes completamente desdentados. Também pode melhorar a sobrevivência dos implantes carregados imediatamente (AU).


Assuntos
Humanos , Masculino , Feminino , Implantes Dentários , Prótese Dentária , Restauração Dentária Permanente , Prótese Total
14.
Rev. Ciênc. Plur ; 7(3): 220-234, set. 2021. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1343609

RESUMO

Introdução:Grande parte dos idosos caracteriza a reabilitação com prótese total como satisfatória. Entretanto, algunsse mostram insatisfeitos devido a dificuldades com a adaptação, principalmente em relação a prótese total mandibular. Objetivo:Identificar a prevalência e os fatores associados ao não uso da prótese total inferior em idosos. Ademais, verificou-se o impacto do não uso dessa prótese na autopercepção de saúde bucal e na dificuldade de se alimentar. Método:Trata-se de um estudo de base populacional e transversal. Para a sua realização, foi utilizado a base de dados da última Pesquisa Nacional de Saúde realizada no Brasil. Inicialmente, o teste Qui-quadrado foi usado para a análise dos dados. Em seguida, uma análise multivariada do tipo regressão múltipla de Poisson foi realizada para o ajuste das razões de prevalência. Resultados:Participaram 4.582 idosos brasileiros, dos quais 27,1% não faziam uso da prótese total inferior. Onão uso da prótese esteve associada aos idosos mais velhos (p=0,001), aos sem instrução (p=0,001), aos que não possuem plano de saúde (p=0,019), aos que fumam (p=0,012) e aos que não realizavam higiene bucal todos os dias (p<0,001). O não uso da prótese total inferior impactou em uma pior autopercepção de saúde bucal (p=0,001) e em maiores dificuldades de se alimentar (p<0,001). Conclusões:Onão uso de prótese total inferior está associado a piores condições socioeconômicas e a um pior estilo de vida, fortemente ligado ao ato de fumar. Ademais, o não uso da prótese impacta negativamente na autopercepção de saúde bucal e na alimentação (AU).


Introduction:A large part of the elderly characterizes rehabilitation with total prosthesis as satisfactory. However, some are dissatisfied due to difficulties with adaptation, mainly in relation to total mandibular prosthesis.Objective:To identify the prevalence and factors associated with not using the lower denture in the elderly. In addition, the impact of not using this prosthesis on self-perceived oral health and the difficulty of eating was verified.Methods:This is a population-based and cross-sectional study. For its realization, the database of the last National Health Survey carried out in Brazil was used. Initially, the Chi-square test was used for data analysis. Then, a multivariate analysis using Poisson multiple regression was performed to adjust the prevalence ratios.Results:4,582 elderly Brazilians participated, of which 27.1% did not use the lower total prosthesis. Failure to use the prosthesis was associated with older elderly people (p=0.001), those without education (p=0.001), those who do not have health insurance (p=0.019), those who smoke (p=0.012) and those who they did not perform oral hygiene every day (p<0.001). Failure to use the lower denture impacted worse self-perceived oral health (p=0.001) and greater difficulties in eating (p<0.001). Conclusions:Failure to use a lower denture is associated with worse socioeconomic conditions and a worse lifestyle, strongly linked to smoking. In addition, the non-use of the prosthesis has a negative impact on self-perception of oral health and food (AU).


Introducción:Una gran parte de los ancianos caracteriza la rehabilitación con prótesis total como satisfactoria. Sin embargo, algunos están insatisfechos por dificultades de adaptación, principalmente en relación con la prótesis total mandibular.Objetivo:Identificar la prevalencia y los factoresasociados a la no utilización de la prótesis inferior en el anciano. Además, se verificó el impacto de no utilizar esta prótesis sobre la salud bucal autopercibida y la dificultad para comer. Método:Se trata de un estudio poblacional y transversal. Para su realización se utilizó la base de datos de la última Encuesta Nacional de Salud realizada en Brasil. Inicialmente, se utilizó la prueba de Chi-cuadrado para el análisis de datos. Luego, se realizó un análisis multivariado utilizando regresión múltiple de Poisson para ajustar las razones de prevalencia.Resultados:Participaron 4.582 ancianos brasileños, de los cuales el 27,1% no utilizó la prótesis total inferior. La falta de uso de la prótesis se asoció con ancianos (p=0,001), sin educación (p=0,001), sin seguro médico (p=0,019), con tabaquismo (p=0,012) y con los que no realizaban tratamiento oral. higiene todos los días (p<0,001). La no utilización de la dentadura inferior repercutió en una peor salud bucal autopercibida (p=0,001) y mayores dificultades para comer (p<0,001).Conclusiones:La no utilización de una dentadura inferior se asocia con peores condiciones socioeconómicas y un peor estilo de vida, fuertemente ligado al tabaquismo. Además, la no utilización de la prótesis tiene un impacto negativo en la autopercepción de la salud bucal y la alimentación (AU).


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Brasil/epidemiologia , Idoso , Saúde Bucal , Prótese Total , Prótese Total Inferior , Reabilitação Bucal/instrumentação , Higiene Bucal , Qualidade de Vida , Distribuição de Qui-Quadrado , Estudos Transversais/métodos , Análise Multivariada , Inquéritos e Questionários , Análise de Dados
15.
Braz. dent. j ; 32(2): 64-71, Mar.-Apr. 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1339323

RESUMO

Abstract This study evaluated the dental displacement in dentures included in different flasks and processed by the Australian cycle modified or by microwave. Metal pins were placed on the teeth as reference for measurements: a) Incisal edge of maxillary and mandibular central incisors, buccal cusp of maxillary and mandibular vestibular first premolars, and mesiobuccal maxillary and mandibular cusps of second molars; b) Incisor to incisor, premolar to premolar and molar to molar; c) Left incisor to left molar and right incisor to right molar, and d) Vertical. Dentures were divided according to flasks (n=10): G1- Metal; G2- HH bimaxillary metal; G3-Microwaves; G4- HH bimaxillary microwaves. For G1 and G2, polymerization at 65ºC/30 min, flame quenched for 30 min, heating at 65ºC/30 min, boiling water for 1 h. For G3 and G4, microwave (20 min/140 W and 5 min/560 W). Comparator microscope with digital camera and analytical unit assessed the measurements before and after denture polymerization. The final distance was made subtracting the distance before the denture processing from the distance of the dental displacement after processing. The value of the difference was submitted to 2-way ANOVA, considering the flask type and denture type. Maxillary denture showed greater displacement when compared to mandibular denture. Flask types and interaction with denture types showed similar difference between before and after polymerization. In conclusion, displacement promoted by flask types in dentures cured by polymerization cycles promoted similar effect on the distance between teeth. Greater value for distance between teeth occurred for maxillary denture.


Resumo O objetivo neste estudo foi avaliar o deslocamento dental em próteses totais incluídas em diferentes tipos de muflas e polimerizadas pelo ciclo australiano ou por micro ondas. Pinos metálicos foram colocados nos dentes como pontos de referência para as medidas: a) Borda incisal dos incisivos centrais maxilares e mandibulares, cúspide vestibular dos primeiros pré molares maxilares e mandibulares e cúspides mésiovestibulares dos segundos molares maxilares e mandibulares; b) Distâncias látero-laterais incisivo a incisivo, pré-molar a pré-molar e molar a molar; c) Distâncias horizontais anteroposterior incisivo esquerdo a molar esquerdo e incisivo direito a molar direito, e d) Vertical. As próteses foram separadas de acordo com o tipo de mufla (n=20): G1- Metálica; G2-HH bi-maxilar metálica; G3- Micro-ondas; G4- HH bi-maxilar micro ondas. Ciclo de polimerização para G1 e G2, água a 65ºC por 30 minutos, aquecimento interrompido por 30 minutos, reaquecimento a 65ºC por 30 minutos, seguido de água fervente por 1 hora. Para G3 e G4, micro ondas (20 minutos a 140 W e 5 minutos a 560 W). As medidas foram avaliadas com microscópio comparador linear. A distância final entre os dentes foi obtida subtraindo o valor da distância antes do processamento da prótese do valor da distância resultante do deslocamento dentário após o processamento. A diferença obtida entre essas distâncias foi submetida à ANOVA de 2 fatores, considerando como variáveis tipo de mufla e tipo de prótese. A prótese maxilar apresentou maior deslocamento dental quando comparada à mandibular. Os tipos de muflas e a interação com os tipos de próteses mostraram movimentos dentais similares antes e depois da polimerização. Em conclusão, o deslocamento dental promovido por diferentes tipos de frascos em próteses curadas por diferentes ciclos de polimerização promoveu efeito semelhante na alteração da distância entre os dentes. Maior valor para a mudança de distância entre os dentes ocorreu na prótese maxilar.


Assuntos
Prótese Total , Austrália , Polimerização
16.
Rev. Odontol. Araçatuba (Impr.) ; 42(1): 24-32, jan.-abr. 2021. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1148164

RESUMO

O uso de próteses mal adaptadas pode ocasionar o surgimento de processos proliferativos não neoplásicos. A hiperplasia fibrosa inflamatória (HFI) é uma lesão benigna, proveniente de reação hiperplásica do tecido conjuntivo fibroso em resposta às injúrias crônicas de baixa intensidade. O objetivo do presente trabalho é relatar um caso clínico sobre remoção cirúrgica de HFI, seguida de reabilitação oral com próteses removíveis. Paciente de 75 anos do sexo masculino relatou que gostaria de fazer a troca da sua prótese, pois a mesma estava fraturada. Ao exame clínico intra-oral constatou-se que suas próteses possuíam higienização precária, e, a superior, possuía uma borda cortante que causou uma lesão hiperplásica na região de fundo de vestíbulo anterior. Quanto ao aspecto clínico, apresentava-se com consistência fibrosa e firme à palpação, de coloração semelhante a mucosa e assintomática. O plano de tratamento proposto foi reembasamento da prótese antiga com resina Soft Confort (Dencril, Brasil) eliminando as áreas que traumatizavam a mucosa, cirurgia pré-protética para a remoção da HFI, exame histopatológico e a confecção de novas próteses, sendo a superior prótese total convencional e a inferior prótese parcial removível. Observa-se a importância no cuidado do planejamento reabilitador protético dos pacientes, pois, como foi descrito neste caso, em algumas situações pode haver necessidade de lançarmos mão de diversas modalidades de tratamento prévias à reabilitação(AU)


The use of poorly adapted prostheses can lead to the emergence of non-neoplastic proliferative processes. Inflammatory fibrous hyperplasia (HFI) is a benign lesion, resulting from a hyperplastic reaction of fibrous connective tissue in response to low-intensity chronic injuries. The aim of the present study is to report a clinical case about surgical removal of HFI, followed by oral rehabilitation with removable prostheses. A 75-year-old male patient reported that he would like to change his prosthesis, because it was fractured. On intra-oral clinical examination, it was found that his prostheses had poor hygiene, and the upper one had a cutting edge that caused a hyperplastic lesion in the deep region of the anterior vestibule. As for the clinical aspect, it was fibrous and firm on palpation, mucosa-like and asymptomatic. The proposed treatment plan was to repurpose the old prosthesis with Soft Confort resin (Dencril, Brazil), eliminating the areas that traumatized the mucosa, pre-prosthetic surgery for the removal of HFI, histopathological examination and the making of new prostheses, the upper prosthesis being conventional total and the lower partial removable prosthesis. It is observed the importance in the care of the prosthetic rehabilitation planning of the patients, because, as it was described in this case, in some situations it may be necessary to resort to different treatment modalities prior to the rehabilitation(AU)


Assuntos
Planejamento de Prótese Dentária , Hiperplasia , Tecido Conjuntivo , Prótese Total , Prótese Parcial Removível , Reembasamento de Dentadura
17.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1346680

RESUMO

ABSTRACT Objective: To evaluate the influence of tooth loss and the use of removable dentures on chewing function and nutritional status of institutionalized elders. Material and Methods: Cross-sectional study with 155 elders from seven long-stay institutions in João Pessoa, Brazil. The participants were classified according to the presence of reminiscent teeth and use of dentures in four levels: toothless, without denture (1); toothless with a complete denture (2); partial toothless without denture (3) and partial toothless with a partial denture (4). Nutritional status was assessed using the Mini-Nutritional Assessment (MNA) instrument and the Body Mass Index (BMI). Swallowing threshold was used for the assessment of masticatory function, using a portion of roasted peanuts (3.7 g). Comparisons among groups were performed using Kruskal-Wallis test with Bonferroni adjustment, considering p<0.05. Results: MNA (p=0.702) and BMI (p=0.884) were not modified in relation to the presence of teeth and denture use. Toothless individuals without dentures had a lower swallowing threshold (p<0.001), whilst partial toothless with dentures had better masticatory function (p>0.05). Conclusion: The presence of reminiscent teeth and the use of dentures do not influence the nutritional status of the elders but interfere with the masticatory function. Prosthetic rehabilitation is desirable for complete toothless individuals.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Brasil , Estado Nutricional , Prótese Total , Prótese Parcial Removível , Instituição de Longa Permanência para Idosos , Mastigação/fisiologia , Idoso , Índice de Massa Corporal , Estudos Transversais/métodos , Boca Edêntula , Estatísticas não Paramétricas
18.
Braz. dent. sci ; 24(2): 1-7, 2021. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1177576

RESUMO

Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain. (AU)


Objetivo: Avaliar o efeito da altura da fibromucosa na distribuição de tensões e deslocamento das próteses totais mandibulares durante a carga unilateral posterior, carga bilateral posterior e orientação anterior usando a análise por elementos finitos (FEA). Material e métodos: Modelos virtuais 3D foram confeccionados para simular a tensão gerada durante diferentes movimentos mandibulares em uma prótese total. Os contatos foram simulados de acordo com a fisiologia, sendo considerados perfeitamente unidos entre os ossos corticais e medulares; e entre o osso cortical e a mucosa. O contato friccional não linear foi utilizado entre a base total da prótese e a fibromucosa, permitindo que a prótese deslizasse sobre o tecido. A base do osso cortical foi fixada e a carga de 100 N aplicada como carga unilateral, carga bilateral posterior e simulação de guia incisiva anterior. Os resultados foram calculados em tensão máxima principal (MPa), microdeformação (mm/mm) e deslocamento total (mm). Os resultados numéricos foram convertidos em mapas colorimétricos e organizados de acordo com as escalas correspondentes. Resultados: A tensão gerada em todas as situações foi diretamente proporcional à altura da fibromucosa. Os resultados de tensão máxima principal demonstraram maior magnitude durante a carga anterior, posterior unilateral e posterior bilateral, respectivamente. Apenas a carga unilateral posterior demonstrou aumento da microdeformação óssea, independente da altura da fibromucosa. O deslocamento da prótese foi menor sob carga bilateral posterior. Conclusão: A carga bilateral posterior é indicada para prótese total, pois permite menor deslocamento da prótese, menor concentração de tensões na base da prótese e menor microdeformação óssea (AU)


Assuntos
Análise de Elementos Finitos , Oclusão Dentária , Prótese Total
19.
Braz. dent. j ; 31(4): 399-403, July-Aug. 2020. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132316

RESUMO

Abstract: This cross-sectional observational study with 24 patients evaluated differences in bite force (BF) and masticatory performance (MP) between conventional complete denture (CCD) and implant mandibular overdenture (IMO) users and the correlation between these variables. The BF test was performed bilaterally with an occlusal force device. During the MP test, patients were asked to chew Optocal particles for 40 cycles. The Shapiro Wilk test was employed to verify the normality of the data, the student t test to identify differences between groups, and Pearson's correlation to investigate interrelationships between variables. A multiple linear regression was subsequently performed via the stepwise method. P values ≤0.05 were considered statistically significant. Unlike IMO users, CCD users presented a significant difference (25.6%) in BF between the dominant and non-dominant chewing side (p=0.04). IMO users presented significantly higher BF (p=0.01) without presenting a dominant side (p=0.38), and also performed significantly better for the following MP parameters: MPX50 values decreased by 27.25% in IMO users (p=0.01), MPB decreased by 48.38% (p=0.01), and ME 5.6 decreased by 53.25% (p=0.02), while ME2.8 increased by 151.57% (p=0.01). The BF and MPX50 in the IMO wearers group were negatively correlated (-0.57; p=0.05); this correlation coefficient was the only parameter included in the multivariate regression model. IMO users have higher BF and better masticatory performance than CCD users, especially in terms of chewed particles size reduction. MP is correlated with a higher BF in IMO users through better particle trituration.


Resumo Este estudo observacional transversal com 24 participantes teve como objetivo avaliar as diferenças na força de mordida (FM) e na PM (performance mastigatória) entre usuários de prótese total convencional (PTC) e de overdenture mandibular (OM) e a correlação entre essas variáveis. O teste de FM foi realizado bilateralmente com um dispositivo de força oclusal. Durante o teste de PM, os pacientes foram solicitados a mastigar uma porção padronizada de Optocal por 40 ciclos mastigatórios. O teste de Shapiro Wilk foi empregado para verificar a normalidade dos dados, o teste T de Student para identificar diferenças entre os grupos e os coeficientes de correlação de Pearson para investigar inter-relações entre variáveis. Uma regressão linear múltipla foi realizada pelo método stepwise. Valores de p≤0,05 foram considerados estatisticamente significantes. Diferentemente dos usuários de OM, os usuários de PTC apresentaram uma diferença significativa (34%) na FM entre o lado dominante e o não dominante (p=0,04). Os usuários de OM apresentaram FM significativamente maior (p=0,01) sem apresentar um lado dominante (p=0,38) e obtiveram PM significativamente melhor nos seguintes parâmetros: os valores de PMX50 diminuíram 27,25% (p=0,01), PMB diminuiu em 48,38% (p=0,01), e EM 5.6 diminuiu 53,25% (p=0,02), enquanto EM2.8 aumentou 151,57% (p=0,01). A FM e PMX50 no grupo de usuários da IMO foram negativamente correlacionados (-0,57;p=0,05); esse coeficiente de correlação foi o único parâmetro incluído no modelo de regressão multivariada. Os usuários da OM possuem maior FM e melhor performance mastigatória do que os usuários de PTC, observados principalmente na redução do tamanho das partículas mastigadas. A PM está correlacionada com um maior FM nos usuários da OM através de uma melhor trituração de partículas.


Assuntos
Humanos , Força de Mordida , Revestimento de Dentadura , Estudos Transversais , Prótese Total , Mandíbula
20.
Rev. Ciênc. Plur ; 6(1): 137-149, 2020. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1052873

RESUMO

Introdução:Aenorme dificuldade de deglutição e fala apresentada em pacientes que sofreram maxilectomiatotal ou parcial por consequência de patologias bucais, afeta grande parte da população que realizou tal procedimento. A alternativa de minimizar o impacto causado pela sequela deixada após cirurgia em maxila está na confecção de um obturador palatino, que tem como objetivo obstruir a comunicação oronasal.Objetivo:Este trabalho objetivou descrever um relato de caso evidenciando o passo a passo clínico e laboratorial de uma prótese total obturadorae a satisfação do paciente com a mesma.Método:Paciente do gênero masculino, maxilectomizado há seisanos devido a presença de um CarcinomaAdenóideCístico foi reabilitado com prótese total obturadora superior e prótese total convencional inferior. A reabilitação superior seguiu os mesmos passos de uma prótesetotal convencional, com exceção da moldagem funcional, na qual foi feita a moldagem da comunicação bucosinusal com silicona de condensação antes da moldagem do selado periférico e moldagem funcional propriamente dita. Na etapa laboratorial, foi necessáriaa realização de três prensagens a fim de deixar a prótese oca na porção obturadora.Resultados:O tratamento restabeleceu a dimensão vertical perdida, proporcionou uma oclusão adequada, se mostrou melhor esteticamentee o paciente mostrou-se extremamente satisfeito com a reabilitação.Conclusões:Como conclusão, obteve-se uma prótese total obturadora superior com qualidades funcionais e estéticas satisfatórias. Ademais, ao comparar com a antiga, a novamostrou-se satisfatória de acordo com a percepção do usuário epossui um menor peso, favorecendo uma melhor retenção (AU).


Introduction:The enormous difficulty in swallowing and speaking presented in patients who underwent total or partial maxillectomy as a result of oral pathologies affects a large part of the population that performed this procedure. The alternative of minimizing the impact caused by the sequelae left after maxillary surgery is by making a palatal obturator, which aims to obstruct oronasal communication.Objective:This study aimed to describe a case report highlighting the clinical and laboratory step by step of a complete obturator prosthesis and patient satisfaction with it. Methods:A male patient who had been maxillectomized for 6 years due to the presence of a cystic adenoid carcinoma was rehabilitated with superior obturator total denture and inferior conventional total denture. The superior rehabilitation followed the same steps of a conventional total prosthesis, except for the functional molding, in which the bucosinusal communication with condensation silicon was molded before the peripheral sealing molding and the functional molding itself. In the laboratory stage, it was necessary to perform three presses in order to leave the hollow prosthesis in the obturator portion.Results:The treatment restored the lost vertical dimension, provided an adequate occlusion,was better aesthetically and the patient was extremely satisfied with the rehabilitation.Conclusions:In conclusion, a superior total obturator prosthesis with satisfactory functional and aesthetic qualities was obtained. Moreover, when compared to the old one, the new one was satisfactory according to the user's perception and has a lower weight, favoring a better retention (AU).


Introduccion: La enorme dificultad para tragar y hablarpresentada en pacientes que han sufrido una maxillectomía total o parcial como resultado de patologías orales afecta a gran parte de la población que realizó este procedimiento. La alternativa de minimizar el impacto causado por las secuelas que quedan después de la cirugía maxilar es hacer un obturador palatino, que tiene como objetivo obstruir la comunicación oronasal. Objetivo: Este estudio tuvo como objetivo describir un informe de caso que muestra la clínica y el laboratorio paso a paso de una prótesis obturadora completa y la satisfacción del paciente con ella. Método:Un paciente masculino que había sido maxillectomizado durante seis años debido a la presencia de un carcinoma adenoide quístico fue rehabilitado con una prótesis obturadora total superior y una prótesis total inferior convencional. La rehabilitación superior siguió los mismos pasos de una prótesis total convencional, excepto el moldeado funcional, en el cual la comunicación bucosinusal con silicio de condensación se moldeó antes del moldeado de sellado periférico y el moldeado funcional en sí. En la etapa de laboratorio, fue necesario realizar tres prensas para dejar la prótesis hueca en la porción del obturador. Resultados:El tratamiento restableció la dimensión vertical perdida, proporcionó una oclusión adecuada, fue mejor estéticamente y el paciente quedó extremadamente satisfecho con la rehabilitación. Conclusiones:Como conclusión, se obtuvo una prótesis obturadora superior con cualidades funcionales y estéticas satisfactorias. Además, en comparación con el anterior, el nuevo fue satisfactorio de acuerdo con la percepción del usuario y tiene un peso menor, lo que favorece una mejor retención (AU).


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Obturadores Palatinos , Cirurgia Bucal/reabilitação , Satisfação do Paciente , Prótese Maxilofacial , Reabilitação Bucal , Brasil , Prótese Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...