Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Filtros aplicados
Intervalo de ano de publicação
1.
Dent. press endod ; 2(3): 36-41, 2012. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-686412

RESUMO

Objetivo: analisar, in vitro, o pH de seis pastas endodônticas à base de hidróxido de cálcio [Ca(OH)2]. Métodos:foram formados seis grupos (n = 5 pastas/grupo) mais um grupo controle (água destilada): G1: Ca(OH)2, propilenoglicol 400 (PEG 400) e paramonoclorofenol canforado(PMCC); G2: Ca(OH)2, iodofórmio 1:1, PEG 400 ePMCC; G3: Ca(OH)2, iodofórmio 4:1, PEG 400 e PMCC;G4: Ca(OH)2 e Otosporim®; G5: Ca(OH)2 e óleo de oliva;G6: Ca(OH)2 e clorexidina gel 2%. As pastas foram previamente colocadas em água destilada e armazenadas a 37°C, sendo o pH de cada amostra avaliado em 7 intervalos de tempo diferentes. O ensaio foi realizado em duas etapas, sendo que na segunda fase foi realizada a troca da água destilada após cada leitura. Resultados:em ambas as etapas não foi observada diferença estatisticamente significativa entre os valores de pH do G1,G2, G3 e G4 (p>0,05) nos 7 tempos avaliados. Todos os grupos apresentaram pH mais elevado em relaçãoa o do G5 e do grupo controle (p<0,05), os quais foram estatisticamente iguais entre si (p>0,05). Conclusão:as pastas apresentaram pH alcalino, com variações em função da sua composição, havendo uma dissociação maior quando alguma substância viscosa estava presente na composição


Assuntos
Análise de Variância , Hidróxido de Cálcio , Materiais Dentários , Difusão , Endodontia
2.
RGO (Porto Alegre) ; 59(3): 373-378, jul.-set. 2011. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-874641

RESUMO

Objective: The purpose of this study was to assess if 4% articaine with 1:100,000 epinephrine (DFL®, Rio de Janeiro, Brazil) provides the necessary diffusion to anesthetize dental pulps innervated by the anterior and medium branches of the superior alveolar nerve as well as the nasopalatine region after posterior superior alveolar nerve block. Methods: In this descriptive and quantitative study, selected total of 30 patients was selected, with healthy superior-lateral incisors and first premolars, who were submitted to cold testing of the pulp, puncture of the nasopalatine region and identification of the stimuli on the visual analogue Faces Pain Scale. This procedure was repeated in two stages, four minutes and eight minutes after the posterior superior alveolar nerve block with articaine.Results: Eight minutes after the injection, 50% of patients reported complete absence of pain (score zero) in the lateral incisor tested, 80% in the premolar and 36.67% in the nasopalatine region. No statistically significant diffusion was recorded in either gender (p = 0.26) or between different age groups (p=0.29). Conclusion: Diffusion did not occur with the expected intensity in all patients, which does not exclude the use of anesthetic block on these nerves when an intervention is needed in the region.


Objetivo: Avaliar se a articaína a 4% com epinefrina 1:100.000 (DFL®, Rio de Janeiro, Brazil) apresenta uma difusão capaz de insensibilizar as polpas dentárias inervadas pelos ramos médio e anterior do nervo alveolar superior e insensibilizar, também, a região nasopalatina, quando utilizado o bloqueio anestésico do nervo alveolar superior posterior.Métodos: Neste estudo descritivo e quantitativo, foram selecionados 30 pacientes com incisivo lateral superior e primeiro pré-molar superior hígidos, os quais foram submetidos a teste pulpar a frio e punção na região nasopalatina e identificação dos estímulos na Escala de Faces de Dor. Este procedimento foi repetido em duas etapas: com quatro minutos e oito minutos após o bloqueio do nervo alveolar superior posterior com articaína. Resultados: Em seguida aos testes de sensibilidade, verificou-se que após oito minutos da anestesia por bloqueio, 50.00% dos pacientes referiram ausência de dor (escore zero) no incisivo lateral testado, 80.00% no pré-molar e 36,67% na região nasopalatina. Não foi registrada difusão estatisticamente significante em relação aos sexos (p = 0,26) e entre as faixas etárias analisadas (p = 0,29). Conclusão: Esta difusão não ocorreu em todos os pacientes com a intensidade esperada, o que não descarta o uso do bloqueio destes nervos quando houver necessidade de intervenção na região.


Assuntos
Carticaína , Difusão , Nervo Maxilar
3.
Araraquara; s.n; mar. 2006. 201 p. tab, ilus, graf.
Tese em Português | BBO - Odontologia, LILACS | ID: biblio-864451

RESUMO

Com o desenvolvimento dos aparelhos LEDs para fotopolimerização de resinas compostas, intensidades maiores puderam ser atingidas sem grandes elevações de temperatura na massa da resina composta e na estrutura dental decorrentes da irradiância em comparação a aparelhos halógenos. Esse novo cenário foi o ponto de partida para o desenvolvimento desse trabalho que utilizou variadas temperaturas de cura (Tcura) (0, 25, 50, 75, 100°C) para a fotopolimerização de uma resina composta (Filtek Z250, 3M ESPE) por 40 e 60 segundos, utilizando o aparelho halógeno Gnatus Optilight Digital (halógeno) e dois LEDs que empregam uma nova tecnologia de montagem de diodos: LEC 1000 e Bright LEC (MM Optics)(LED 1 e LED2 respectivamente). A influência da temperatura de cura somada a outras variáveis estudadas foram avaliadas utilizando uma metodologia desenvolvida e aprimorada no IFSC/USP em que a penetração de um corante fluorescente no corpo da resina composta polimerizada é quantificada utilizando espectroscopia de fluorescência. De acordo com os dados finais submetidos à análise de variância, pode-se averiguar a presença de dois grupos de resultados: entre 0 e 25°C em que ambas obtiveram uma maior porcentagem de pentração do corante comparado às outras Tcura com uma variação na penetração de 69,26 +/- 8,19% até 90,99 +/- 3,38%. Na análise desse grupo o efeito tempo e temperatura foram significativos (p<0,05) sendo que a menor penetração de corante ocorreu com 60 segundos de fotoativação e esta penetração foi em média, menor com a Tcura de 25°C. Algumas interações mostraram que houve dependência entre aparelho e tempo e entre tempo e temperatura; o outro grupo refere-se as Tcura de 50, 75 e 100°C em que apesar do valor-p próximo de 0,05, o efeito temperatura foi significativo. A penetração do corante variou de 8,87 +/- 3,55 até 39,47 +/- 8,9%. Os efeitos aparelho e tempo foram altamente significativos. A penetrção com o tempo de 60 segundos foi em média menor. Exceto com o aparelho LED 1, as porcentagens de penetração do corante foram maiores com a Tcura de 100°C. A menor média foi referente a Tcura de 50°C e 60 segundos de fotoativação


With the development of the LED equipment to photopolimerization of composite resin, greater intensities could be reach without greater elevation of temperature in the mass of the composite resin and in the dental structure arisen from the irradiance in comparison to halogens equipments. This new scenario was the beginning for the development of this work that used a variety of cure temperatures (Tcure)(0, 25, 50, 75, 100°C), to a photopolymerization of a composite resin (Filtek Z250, 3M ESPE) for 40 and 60 seconds, using the halogen equipment Gnatus Optilight Digital (halogen) and two LEDs that use a new technology of assembly diodes: LEC 1000 and Bright LEC (MM Optics)(LED 1 and LED 2 respectively). The influence of cure temperature added by other variables studied were evaluated using a methodology developed and improved in the IFSC/USP in that the penetration of a fluorescent dye in the body of the photopolimerized composite resin is quantified using fluorescence spectroscopy. According to the final data submitted to an analysis of variance, it could verify the presence of two groups of results: between 0 and 25 °C both had a great percentage of the dye penetration compared to other Tcure with a variation in penetration from 69,26 +/- 8,19 % up to 90,99 +/- 3,38 %. In this analysis the effect time and temperature were highly expressive (p<0,05) and the smaller dye penetration happened to 60 seconds of photoactivation and this penetration were in media, smaller with the Tcure of 25°C. The results showed that there was interaction between the equipment and time and between time and temperature; the other group is concerning the Tcure from 50, 75 and 100°C in spite of the p-value near 0,05 the effect temperature were expressive. The penetration of the dye ranged from 8,87 +/- 3,55 up to 39,47 +/- 8,9 %. The effect equipment and time were highly expressive. The penetration with the time of 60 seconds was in average smaller. Except with the equipment LED 1, the percentages of the dye penetration were bigger with the Tcure of 100°C. The smallest average were the Tcure of 50°C and 60 seconds of photoactivation


Assuntos
Resinas Compostas , Luzes de Cura Dentária , Difusão , Fluorescência , Luz , Polímeros , Condutividade Térmica , Corantes , Cura Luminosa de Adesivos Dentários
4.
Araraquara; s.n; 2004. 116 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-466920

RESUMO

A utilização de corantes fluorescentes tem ajudado ao estudo da penetração de sistemas adesivos na estrutura dental e alguns compósitos, bem como na avaliação da microinfiltração e fendas na interface dente restauração. No caso das resinas compostas, esta técnica pode ser útil na verificação da profundidade de polimerização e vulnerabilidade físico-química das mesmas a corantes orgânicos. Neste intuito, nos propusemos a avaliar por meio de espectroscopia de fluorescência, a difusão de um corante orgânico em resinas compostas em função dos fatores: 1. Tipo de resina, 2. Fonte de luz, 3. Tempo de polimerização e 4. Tempo de imersão no corante. Para isso, foram realizados 2 grupos experimentais de acordo com a fonte de luz: lâmpada halógena - Grupo H e sistema LEDs - Grupo L. Cada grupo foi subdividido de acordo com a resina utilizada: 1. Micropartícula (Filtek A110/3M), 2. Híbrida (Z100/3M) e 3. Compactável (P60/3M), onde cada subgrupo teve 2 tempos de polimerização: 40 e 60 segundos, e 3 tempos de imersão em solução de Rodamina 6G a 0,1 percento em etilenoglicol: 0, 24 e 48 horas. Cada subgrupo possuía 5 amostras de 4 mm de diâmetro e 4 mm de espessura. Completados os tempos de imersão, foi obtida 1 fatia de 1,5 mm de espessura de cada amostra...


Assuntos
Resinas Compostas , Difusão , Fluorescência
5.
JBC j. bras. clin. estet. odontol ; 3(17): 46-51, set. 1999. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-427693

RESUMO

Atividade antibacteriana do óleo essencial e da resina da Copaire multijuga associados ao hidróxido de cálcio e ao óxido de zinco foi avaliada, visando sua introdução na Odontologia, tendo em vista as propriedades medicinais deste óleo. O óleo bruto foi submetido à análise por cromatografia gasosa e destilação para obtenção de suas frações (óleo essencial e a resina). Foram confeccionadas pastas experimentais de hidróxido de cálcio ou óxido de zinco associadas ao óleo essencial ou a resina de copaíba na proporção 1:1 ou 2:1. A avaliação da atividade antibacteriana foi realizada pelo Método de Difusão e pela determinação da Concentração Inibitória Mínima e da Concentração Bacteriana Mínima à frente à Pseudomonas aeruginosa e Streptococcus mutans. As pastas experimentais apresentaram atividade antibacteriana frente ao Streptococcus mutans; o óleo essencial apresentou melhor atividade antibacteriana do que a resina quando avaliadi isoladamente; o óleo bruto foi bacteriostático e bactericida frente ao Streptococcus mutans


Assuntos
Cremes Dentais/farmacologia , Óleos Voláteis , Placa Dentária/microbiologia , Hidróxido de Cálcio , Difusão , Eugenol , Testes de Sensibilidade Microbiana , Polietilenoglicóis , Pseudomonas aeruginosa , Resinas Vegetais , Streptococcus mutans , Óxido de Zinco
6.
JBC j. bras. clin. estet. odontol ; 3(15): 67-69, maio 1999. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-415766

RESUMO

A atividade antibacteriana de 6 materiais usados como seladores temporários foi avaliada e comparada. Para isto, foram utilizadas 4 espécies bacterianas comumente associadas a processos patológicos na cavidade oral. O teste de difusão em ágar foi a metodologia utilizada. As bactérias testadas foram semeadas sobre placas de ágar e os materiais testados colocados em furos no ágar. Após 48 horas, os halos de inibição de crescimento bacteriano foram mensurados em torno dos materiais. Foi demonstrado que todos os materias testados apresentaram atividade antibacteriana. No geral, Coltsol, Pulpo-San e OZE foram os mais eficazes. Vidron-R, um cimento ionomérico, produziu os menores halos de inibição. Os prováveis mecanismos responsáveis pela eficácia antibacteriana dos materiais são discutidos


Assuntos
Bactérias Anaeróbias , Cimentos Dentários/farmacologia , Materiais Dentários/farmacologia , Ágar , Crescimento Bacteriano , Boca/microbiologia , Meios de Cultura , Difusão
7.
Braz. dent. j ; 6(1): 5-9, jan.-jul. 1995. tab
Artigo em Inglês | BBO - Odontologia | ID: biblio-850402

RESUMO

The aim of this study was to analyze in vitro the dentinal diffusion of hydroxyl ions of calcium hidroxide pastes, prepared with different acid-base vehicles, in an inert nitrogen atmosphere. Sixty maxillary central incisors with mature apexes were selected and after and access and root canal preparation each root was filled with calcium hydroxide pastes prepared with different vehicles: saline solution, anesthetic and polyethylene glycol 400. The roots were then sectioned 2mm from the apical vertex and the teeth mounted in the center of a round platform, filled with saline solution up to 2mm from the root tip. The platforms remained inert in an atmosphere of nitrogen, completely sealed, in the absence of light and with a constant temperature of 36.5ºC. Diffusion analysis of the hydroxyl ions was carried out by a colorimetric method on days 7, 15, 30, 45 and 60. Calcium hydroxide pastes prepared with saline solution and anesthetic showed a pH change of 6-7 to 7-8 after 30 days, remaining at this level at 60 days. In the polythylene glycol 400 group, the same alteration occurred at 45 days, and continued at 60 days


Assuntos
Hidróxido de Cálcio/análise , Permeabilidade da Dentina/efeitos dos fármacos , Dentina/efeitos dos fármacos , Difusão , Concentração de Íons de Hidrogênio , Técnicas In Vitro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...