Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Filtros aplicados
Intervalo de ano de publicação
1.
J. appl. oral sci ; 25(5): 490-497, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893659

RESUMO

Abstract Periodontal research involves the use of animal models to better understand the biological processes of periodontal diseases and the potential of new or existing therapies. Currently, ligature-induced periodontitis in rats is the main model used in periodontal research, in this model, alveolar bone loss (ABL) is the main parameter evaluated by radiographic, morphometric, and histological techniques. Interestingly, although these methodologies are widely used, it is not totally clarified neither the kinetics of ABL over the induction time nor the agreement degree (repeatability and reproducibility) of these techniques. Objective: To characterize ABL kinetics at 0, 3, 7, 15, 30, and 60 days after ABL induction by ligature and to evaluate the intra- (repeatability) and inter-examiner (reproducibility) agreement and the correlation among the radiographic, morphometric, and histological methodologies. Material and Methods: 60 male Wistar rats with induced ABL were randomly divided into 6 experimental groups (n = 10 animals/group). After 0, 3, 7, 15, 30, and 60 days, the animals were euthanized and their hemimandibles were removed for ABL determination using radiographic, morphometric and histological techniques. Results: Radiographic and morphometric/linear techniques allowed the detection of statistically significant ABL on the third day, while histological and morphometric/area techniques could only detect ABL after the seventh day (ANOVA/Tukey, p<0.05). After the fifteenth day, except for histological analysis, the ABL was stabilized. Concerning the agreement of the methodologies, Bland Altman's test (intra and inter-examiner evaluations) showed no difference among the measurements (p>0.05). In addition, high correlations (Pearson's test, r2>0.9, p<0.05) were observed. Conclusion: The results indicated that the minimum time for ABL induction could vary from 3 to 7 days, according to the chosen analysis methodology. Agreement and correlation data support the comparison of results between studies with same induction time.


Assuntos
Animais , Masculino , Periodontite/etiologia , Periodontite/patologia , Perda do Osso Alveolar/patologia , Periodontite/diagnóstico por imagem , Valores de Referência , Fatores de Tempo , Cinética , Radiografia Dentária , Distribuição Aleatória , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Perda do Osso Alveolar/etiologia , Perda do Osso Alveolar/diagnóstico por imagem , Ratos Wistar , Modelos Animais de Doenças , Ligadura
2.
São Paulo; s.n; 2012. 152 p. ilus, tab, graf. (BR).
Tese em Português | LILACS, BBO - Odontologia | ID: lil-682234

RESUMO

OBJETIVO: caracterizar a interação entre tensão e cinética de polimerização e seus parâmetros determinantes, e avaliar a qualidade da rede polimérica e propriedades mecânicas de compósitos comerciais para dentes posteriores a base de dimetacrilato ou de silorano. A cinética de polimerização foi avaliada sob influência da intensidade da fonte de luz, da temperatura e da umidade. Por fim, o grau de conversão (GC) do compósito a base de silorano foi avaliado por espectroscopia e titulação. MÉTODOS: foram utilizados três compósitos de baixa contração: Kalore (KAL - GC America) e N´Durance (NDUR Septodont), a base de dimetacrilatos; e Filtek P90 (P90 - 3MESPE), a base de silorano. O EsthetX HD (EHD - Dentsply) foi utilizado como controle. A tensão de polimerização (TP) dos espécimes (n = 5; Ø = 5 mm; h = 1 mm, 10 min) foi obtida em máquina universal de ensaios mecânicos. A contração volumétrica (CVol) foi determinada em linômetro (n = 3; Ø = 6 mm; h = 1,5 mm; 10 min). O módulo de elasticidade em flexão (MeFlex) e a resistência à flexão (RFlex) (n = 10; 10 x 2 x 1 mm) foram obtidos através do teste de dobramento em três pontos (8 mm entre apoios; 0.5 mm/min). O GC e a taxa de polimerização (Rp) dos espécimes (n = 3; Ø = 6,5 mm; h = 0,8 mm) foram determinados por espectroscopia no NIR (banda em 6165 cm-1 para dimetacrilatos e em 4156 cm-1 e 4071 cm-1 para silorano). Para os testes acima descritos, a fotopolimerização foi realizada com 740 mW/cm2 x 27 s (Bluephase G2 Ivoclar). A temperatura de transição vítrea (Tg), a tangente de delta (tan delta), o grau de heterogeneidade e a densidade de ligações cruzadas de espécimes (n = 3; 15 x 3 x 1 mm) com o máximo de conversão foram obtidos em analisador dinâmico-mecânico. A análise dos extratos obtidos após imersão dos espécimes (Ø = 12 mm; h = 0,8 mm; 970 mW/cm2 x 30 s) em diclorometano foi realizada através de 1H-NMR para verificar monômeros residuais. A cinética de polimerização de espécimes (n = 3; Ø = 5,5 mm; h = 1 mm) de todos os materiais, fotopolimerizados com Acticure 4000 EXFO e filtro 320-500 nm, foi analisada sob variação de irradiância (3, 30 ou 200 mW/cm2) e de temperatura (23, 35 ou 60 °C) por espectroscopia no NIR (banda em 6165 cm-1 para dimetacrilatos e em 4156 cm-1 para silorano). A influência da umidade a 23, 35 ou 60 °C na cinética de polimerização foi verificada para Filtek P90 e EsthetX HD. Para auxiliar na identificação de bandas que possam ser utilizadas para o GC do Filtek P90, as conversões de bandas referentes a anéis epóxicos selecionadas com a caracterização espectroscópica (Mid-IR e NIR) de monômeros modelos e do Filtek P90 sem carga foram comparadas com os valores encontrados no teste de titulação ácido-base desses materiais. Os dados dos testes laboratoriais, quando necessário, foram submetidos à Anova e ao Teste de Tukey ( < 0,05).


OBJECTIVE: To characterize the interaction between polymerization kinetics and stress and its determining parameters, and evaluate polymer network quality and mechanical properties of commercial composites for posterior teeth based on dimethacrylate or silorane. Also, the influence of the intensity of the light source, temperature and humidity on the polymerization reaction was evaluated. Finally, the degree of conversion (DC) of the composite based on silorane was evaluated by spectroscopy and titration. METHODS: three "low shrinkage" composites were chosen: Kalore (KAL - GC America) and N'Durance (NDUR - Septodont), based on dimethacrylates, and Filtek P90 (P90 - 3MESPE), based on silorane. EsthetX HD (EHD - Dentsply) was used as a control. Polymerization stress (PS) of samples (n = 5, Ø = 5 mm; h = 1 mm, 10 min) was obtained using a universal testing machine. Volumetric shrinkage (VS) was determined in a linometer (n = 3, Ø = 6 mm, h = 1.5 mm, 10 min). Elastic modulus (E) and flexural strength (FS) (n = 10; 10 x 2 x 1 mm) were obtained by three point bending test (8 mm between support, 0.5 mm/min). DC and polymerization rate (Rp) of specimen (n = 3, Ø = 6.5 mm, h = 0.8 mm) were determined by NIR spectroscopy (peak 6165 cm-1 for dimethacrylates and 4156 cm-1 and 4071 cm-1 for silorane). For these tests, photopolymerization was performed with 740 mW/cm2 x 27 s (Bluephase G2 - Ivoclar). Glass transition temperature (Tg), loss tangent (LT), degree of heterogeneity and crosslink density of specimens (n = 3, 15 x 3 x 1 mm) with maximum conversion was obtained in a dynamic mechanical analyzer. Analysis of extracts obtained after specimen immersion (Ø = 12 mm, h = 0.8 mm; 970 mW/cm2 x 30 s) in dichloromethane was carried out using 1H-NMR to determine residual monomers. Polymerization kinetics of specimens (n = 3; Ø = 5.5 mm, h = 1 mm) of all materials cured with Acticure 4000 - EXFO and 320-500 nm filter, was analyzed using different levels of irradiance (3, 30 or 200 mW/cm2) and temperature (23, 35 or 60 °C) by NIR spectroscopy (peak 6165 cm-1 for dimethacrylates and 4156 cm-1 for silorane). The influence of moisture at 23, 35 or 60 °C on polymerization kinetics was observed for Filtek P90 and EsthetX HD. To assist in the identification of peaks that can be used to calculate the conversion of Filtek P90, peaks related to epoxy rings selected with the spectroscopic characterization (Mid-IR and NIR) of model monomers and Filtek P90 (after filler extraction with acetone) were compared with the values found in acid-base titration test of these materials. Data were submitted to ANOVA and Tukey's test ( < 0.05).


Assuntos
Cinética , Polimerização , Percolação/métodos , Ressonância Magnética Nuclear Biomolecular
4.
Bauru; s.n; 2004. 140 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-407615

RESUMO

Há um relacionamento direto entre o uso do flúor e a prevenção da dental dentária. Devido ao aumento da fluorose dentária, deve-se dar ênfase ao controle da ingestão diária de flúor, e, mais que isto, à biodisponibilidade do mesmo. Sendo assim, o objetivo deste trabalho, cruzado e duplo-cego, foi analisar a cinética do flúor liberado na saliva total pela goma de mascar Happydent (0,3 mg F como MFP), sua capacidade de incorporação ao esmalte dentário e sua biodisponibilidade através da saliva do ducto da glândula parótida e urina. Na 1ª fase do experimento a saliva de 10 voluntários foi coletada durante 15 min (tempos 0,3,6,9,12 e 15 min) e duas biópsias, uma antes da mastigação (biópsia "baseline") e outra após, foram realizadas através da aplicação de 5 'mü'L de HCl a 0,5 M, sobre área delimitada na superfície do incisivo, por 15 seg, seguidas da neutralização da área por aplicação de 5 'mü'L de NaOH a 0,25 N, por 2 vezes. A quantidade de flúor tanto na saliva quanto nas biópsias foi medida com o auxílio de eletrodo íon-específico. As concentrações médias de flúor liberada na saliva total após o uso do Happydent® e Trident® foram de 0,187 e 0,002 mg F, respectivamente. A goma de mascar Happydent® foi capaz de produzir uma incorporação média de flúor ao esmalte dentário correspondente a 1474 ppm. Na 2ª fase, após jejum de 12h, cinco voluntários receberam 3 gomas de Happydent (' > OU=' 1 mg MFP) e foram coletadas amostras de saliva do ducto da glândula parótida: antes do início do experimento ("baseline"), a cada 3 min durante os 20 min iniciais, a cada 20 min nas primeiras 2 h, a cada 40 min até 4 h e, por fim, em intervalos de 1 h até completarem-se 8 h do início do experimento. Amostras de urina foram coletadas um dia antes e durante o estudo, por 9 h. O F presente na saliva do ducto foi analisado após difusão facilitada por HMDS e o da urina pelo método direto...


Assuntos
Humanos , Masculino , Feminino , Criança , Goma de Mascar , Flúor , Esmalte Dentário , Cinética , Glândula Parótida , Ductos Salivares
5.
Periodontia ; 5(3): 273-6, jan.-jun. 1996. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-853571

RESUMO

O papel da resposta inflamatório-imonológica na etiopatogênese da doença periodontal é ainda bastante controverso. Pesquisas sugerem que as reações imunológicas contribuem para a destruição tecidual. O presente trabalho avaliou a resposta infamatória apresentada por camundongos normais e por camundongos imunossuprimidos por ciclofosfamida após monoinfecção subcutânea com Porphyromonas gingivalis. Os resultados demonstraram haver desenvolvimento de resposta inflamatória em ambos os grupos, a qual atinge seu pico em 48 horas e se resolve 4 a 7 dias após a inoculação. Entretanto, a administração de ciclofosfamida alterou significativamente a cinética do desenvolvimento desta resposta inflamatória


Assuntos
Animais , Ratos , Ciclofosfamida , Camundongos , Doenças Periodontais , Porphyromonas gingivalis , Cinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...