1.
Acta Paul. Enferm. (Online) ; 35: eAPE03397, 2022. tab, graf
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1402904

RESUMO

Resumo Objetivo Analisar as evidências científicas de práticas de desinfecção de incubadoras usadas em Unidades de Cuidados Intensivos Neonatais. Métodos Revisão integrativa de literatura, realizada de junho a julho de 2020, nas bases de dados: LILACS, SciELO, CINAHL, SCOPUS, Web of Science e MEDLINE. Os achados foram organizados conforme o fluxograma PRISMA e discutidos de acordo com a literatura pertinente. Resultados Dos 780 artigos encontrados, apenas cinco contemplaram os critérios de inclusão. Os saneantes utilizados foram: cloreto de didecildimetilamônio, polihexametilenobiguanida e Peróxido de Hidrogênio (VHP); cloreto de didecildimetilamônio; N-(3-aminopropyl)-N-dodécylpropane-1,3-diamine; cloreto de didecildimetilamônio e limpeza a vapor; água com detergente para limpeza no balde e água sanitária (200mg/L) e desinfectante Umonium38® a 2,5%. Há diversidade de opções para desinfecção das incubadoras, com variação de métodos e frequência de limpeza. Os saneantes utilizados foram eficazes, apontando para redução da carga microbiana. Conclusão Observou-se uma variedade de procedimentos e produtos que podem ser utilizados para limpeza e desinfecção das incubadoras. Os procedimentos de desinfecção favoreceram a redução da contaminação da superfície. No entanto, a presença de micro-organismos, mesmo que reduzida, alerta sobre o risco à segurança do paciente.


Resumen Objetivo Analizar las evidencias científicas de prácticas de desinfección de incubadoras usadas en Unidades de Cuidados Intensivos Neonatales. Métodos Revisión integradora de literatura, realizada de junio a julio de 2020, en las bases de datos: LILACS, SciELO, CINAHL, SCOPUS, Web of Science y MEDLINE. Los resultados fueron organizados de acuerdo con el diagrama de flujo PRISMA y discutidos de acuerdo con la literatura pertinente. Resultados De los 780 artículos encontrados, solamente cinco contemplaron los criterios de inclusión. Los desinfectantes utilizados fueron: cloruro de didecildimetilamonio, polihexametilen biguanida y peróxido de hidrógeno (VHP); cloruro de didecildimetilamonio; N-(3-aminopropil)-N-dodecilpropano-1,3-diamina; cloruro de didecildimetilamonio y limpieza a vapor; agua con detergente para limpieza en el balde y cloro (200mg/L) y desinfectante Umonium38® al 2,5 %. Existe una diversidad de opciones para la desinfección de las incubadoras, con variación de métodos y frecuencia de limpieza. Los desinfectantes utilizados fueron eficaces, lo que indica una reducción de la carga microbiana. Conclusión Se observó una variedad de procedimientos y de productos que se pueden utilizar para la limpieza y la desinfección de las incubadoras. Los procedimientos de desinfección favorecieron la reducción de la contaminación de la superficie. Sin embargo, la presencia de microorganismos, aunque reducida, alerta respecto al riesgo a la seguridad del paciente.


Abstract Objective To analyze the scientific evidence of incubator disinfection practices used in Neonatal Intensive Care Units. Methods This is an integrative literature review, conducted from June to July 2020, in the LILACS, SciELO, CINAHL, Scopus, Web of Science and MEDLINE databases. The findings were organized according to the PRISMA flowchart and discussed according to pertinent literature. Results Of the 780 articles found, only five met the inclusion criteria. The sanitizers used were: didecyldimethylammonium chloride, PHMB and vaporized hydrogen peroxide (VHP); didecyldimethylammonium chloride; N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine; didecyldimethylammonium chloride and steam cleaning; water with detergent for cleaning in the bucket and bleach (200 mg/L) and 2.5% Umonium38® disinfectant. There is a diversity of options for disinfection of incubators, with variation of methods and frequency of cleaning. The sanitants used were effective, pointing to reduction of microbial load. Conclusion A variety of procedures and products were observed that can be used for cleaning and disinfection of incubators. Disinfection procedures favored the reduction of surface contamination. However, the presence of microorganisms, even if reduced, alerts about the risk to patient safety.


Assuntos
Humanos , Terapia Intensiva Neonatal , Indicadores de Contaminação , Desinfecção , Infecção Hospitalar , Incubadoras para Lactentes , Detergentes , Equipamentos e Provisões , Segurança do Paciente
2.
Rev. latinoam. enferm. (Online) ; 30: e3684, 2022. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-1409620

RESUMO

Abstract Objective: to analyze the cleaning process of gastroscopes, colonoscopes and duodenoscopes in eight in-hospital health services. Method: a cross-sectional study conducted with 22 endoscopes (eight gastroscopes, eight colonoscopes and six duodenoscopes), and microbiological analysis of 60 samples of air/water channels (all endoscopes) and elevator (duodenoscopes), in addition to protein testing. Descriptive statistics with calculation of frequencies and central tendency measures was used in data analysis. Results: the processing of 22 endoscopes was monitored with microbiological analysis for 60 channels. In the pre-cleaning procedure, in 82.3% (14/17) of the devices, gauze was used in cleaning the insertion tube. Incomplete immersion of the endoscope in detergent solution occurred in 72.3% (17/22) of the cases, and in 63.6% (14/22) there was no standardization of filling-in of the channels. Friction of the biopsy channel was not performed in 13.6% (3/22) of the devices. In the microbiological analysis, 25% (7/32) of the samples from the stored endoscopes were positive for microbial growth (from 2x101 to 9.5x104 CFU/mL), while after processing, contamination was 32% (9/28). Protein residues in the elevator channel were detected in 33% of duodenoscopes. Conclusion: the results indicate important gaps in the stages of pre-cleaning and cleaning of endoscopes that, associated with presence of protein residues and growth of microorganisms of epidemiological importance, indicate limitations in safety of the processing procedures, which can compromise the disinfection processes and, consequently, their safe use among patients subjected to such tests.


Resumo Objetivo: analisar o processo de limpeza de gastroscópios, colonoscópios e duodenoscópios em oito serviços de saúde intra-hospitalar. Método: estudo transversal com 22 endoscópios, sendo oito gastroscópios, oito colonoscópios e seis duodenoscópios, e análise microbiológica de 60 amostras dos canais de ar/água (todos os endoscópios) e elevador (duodenoscópios), além de teste de proteína. Na análise dos dados, utilizou-se estatística descritiva, com cálculo de frequências e medidas de tendência central. Resultados: o processamento de 22 endoscópios foi acompanhado com análise microbiológica de 60 canais. Na pré-limpeza, em 82,3% (14/17) dos equipamentos, foi utilizada gaze na limpeza do tubo de inserção. A imersão incompleta do endoscópio em solução detergente ocorreu em 72,3% (17/22) dos casos, e em 63,6% (14/22) não havia padronização do preenchimento dos canais. A fricção do canal de biópsia não foi realizada em 13,6% (3/22) dos equipamentos. Na análise microbiológica, 25% (7/32) das amostras dos endoscópios armazenados foram positivas para crescimento microbiano (2x101 a 9,5x104 UFC/mL), enquanto após o processamento, a contaminação foi de 32% (9/28). Resíduos de proteína no canal do elevador foram detectados em 33% dos duodenoscópios. Conclusão: os resultados apontam lacunas importantes nas etapas de pré-limpeza e limpeza dos endoscópios que, associadas à presença de resíduos de proteína e ao crescimento de microrganismo de importância epidemiológica, sinalizam limitações na segurança do processamento, que podem comprometer os processos de desinfecção e consequentemente seu uso seguro entre pacientes submetidos a tais exames.


Resumen Objetivo: analizar el proceso de limpieza de gastroscopios, colonoscopios y duodenoscopios en ocho servicios de salud intrahospitalarios. Método: estudio transversal con 22 endoscopios, de los cuales ocho eran gastroscopios, ocho colonoscopios y seis duodenoscopios, y análisis microbiológico de 60 muestras de los canales de aire/agua (todos los endoscopios) y elevador (duodenoscopios), además de prueba de proteínas. En el análisis de los datos se utilizó estadística descriptiva, con cálculo de frecuencias y medidas de tendencia central. Resultados: el procesamiento de los 22 endoscopios fue monitoreado con el análisis microbiológico de 60 canales. En la prelimpieza, en el 82,3% (14/17) de los equipos se utilizó gasa para limpiar el tubo de inserción. En el 72,3% (17/22) de los casos la inmersión del endoscopio en solución detergente fue incompleta y en el 63,6% (14/22) no hubo estandarización del llenado de los canales. La fricción del canal de biopsia no se realizó en el 13,6% (3/22) de los equipos. En el análisis microbiológico, el 25% (7/32) de las muestras endoscópicas almacenadas dio positivo para crecimiento microbiano (2x101 a 9,5x104 UFC/ml), mientras que después del procesamiento, la contaminación fue del 32% (9/28). Se detectaron residuos de proteína en el canal elevador en el 33% de los duodenoscopios. Conclusión: los resultados indican que hay importantes lagunas en las etapas de prelimpieza y limpieza de los endoscopios que, junto con la presencia de residuos de proteínas y del crecimiento de microorganismos de importancia epidemiológica, indican limitaciones en la seguridad del procesamiento, que pueden comprometer los procesos de desinfección y, por ende, el uso seguro en los pacientes que se someten a esos procedimientos.


Assuntos
Humanos , Desinfecção , Infecção Hospitalar , Contaminação de Equipamentos/prevenção & controle , Estudos Transversais , Endoscópios/microbiologia , Detergentes
3.
Belo Horizonte; s.n; 2018. 92 p. tab, graf, ilus.
Tese em Português | LILACS, BDENF - Enfermagem | ID: biblio-963973

RESUMO

No Brasil, é recomendado que durante a limpeza dos Produtos para Saúde (PPS) o detergente utilizado possua ação enzimática. Embora a Resolução da Diretoria Colegiada nº 55 de 14 de novembro de 2012 da Agência Nacional de Vigilância Sanitária desaconselhe a reutilização desta solução de limpeza, sabe-se que na prática clínica elas são reaproveitadas por diversas vezes para imersão de PPS, como os aparelhos endoscópicos, o que pode comprometer a efetividade da ação do detergente enzimático e com isso a segurança no processamento do PPS. Esta pesquisa objetivou avaliar a carga microbiana presente na solução de detergente enzimático durante sua reutilização na limpeza manual de aparelhos endoscópicos gastrointestinais. Tratou-se de um estudo transversal realizado em um serviço de endoscopia digestiva de um hospital universitário de Belo Horizonte e no Laboratório de Microbiologia Oral e Anaeróbios do ICB/UFMG. A amostra foi composta por 57 aparelhos endoscópicos e 76 alíquotas de solução de detergente enzimáticos coletadas de diversos reusos de 19 diferentes soluções. O material coletado foi agitado em vórtex, acrescido a Caldo Letheem Modificado e submetido a filtração em membrana Millipore® 0,45µm. A membrana foi depositada em Tryptic Soy Ágar para crescimento microbiano. A identificação presuntiva dos micro-organismos foi realizada manualmente considerando-se aspectos morfotintoriais e reações bioquímico/fisiológicas. As variáveis foram descritas utilizando frequências, porcentagens e medidas de tendência central. O projeto foi aprovado pelo Comitê de Ética e Pesquisa da Universidade Federal de Minas Gerais (CAAE ­ 67493417.1.0000.5149). As médias das cargas microbianas na solução de detergente enzimático variaram de 19,9 UFC/mL após primeiro uso, 51,1 UFC/mL após terceiro uso e 67,1UFC/mL após o quinto reuso. Nos canais de ar/água e biópsia houve aumento de micro-organismos Gram negativos ao longo das reutilizações do detergente. Foram recuperados, Enterobacter spp., Escherichia coli, Klebsiella spp., Pseudomonas spp., Staphyloccocus aureus, Staphyloccocus coagulase negativa. Pseudomonas spp. foi o micro-organismo mais identificado em todas as alíquotas coletadas. Verificou-se a importância da escovação do canal de biópsia para correta remoção de micro-organismos. Conclui-se que a reutilização das soluções de detergente enzimático contribuiu para contaminação dos aparelhos endoscópicos com micro-organismos potencialmente patogênicos. Faz-se necessário a reavaliação de protocolos institucionais, no sentido de que seja cumprida a orientação da Anvisa por meio da RDC nº 55 de 14 de novembro de 2012 de que os detergentes enzimáticos não devem ser reutilizados sob perda da eficiência do produto. As características físico químicas dos detergentes enzimáticos devem ser respeitadas pelos serviços de saúde conforme parâmetros estabelecidos pelos fabricantes.(AU)


In Brazil, it is recommended that during the cleaning of Health Products the detergent used has enzymatic action. Although Collegiate Board Resolution No. 55 of November 14, 2012 of the National Agency of Sanitary Surveillance advises against the reuse of this cleaning solution, it is known that in clinical practice they are reused several times for immersion of health products, such a gastrointestinal endoscope, which may compromise the effectiveness of the enzymatic detergent action and thus the safety in the processing. This research aimed to evaluate the microbial load present in the enzymatic detergent solution during its reuse in the manual cleaning of endoscopic gastrointestinal devices. This was a cross-sectional study performed at a gastrointestinal endoscopy service at a university hospital in Belo Horizonte and at the Oral Microbiology and Anaerobic Laboratory of ICB/UFMG. The sample consisted of 57 endoscopes and 76 aliquots of enzymatic detergent solution collected from several replicates of 19 different solutions. The collected material was vortexed, added to Modified Letheem Broth and subjected to Millipore® 0.45 µm membrane filtration. The membrane was deposited in Tryptic Soy Ágar for microbial growth. The identification of the microorganisms was performed manually considering morphotintorial aspects and biochemical/physiological reactions. The variables were described using frequencies, percentages and measures of central tendency. The project was approved by the Ethics and Research Committee of the Federal University of Minas Gerais (CAAE - 67493417.1.0000.5149). The mean values of the microbial loads in the enzymatic detergent solution varied from 19.9 UFC/mL after first use, 51.1 UFC/mL after third use and 67.1 UFC/mL after the fifth reuse. In the air/water and biopsy channels there was an increase of Gram negative microorganisms along the reuse of the detergent. Enterobacter spp., Escherichia coli, Klebsiella spp., Pseudomonas spp., Staphylococcus aureus, Coagulase-negative Staphyloccocus were recovered. Pseudomonas spp. was the most identified microorganism in all aliquots collected. It was verified the importance of brushing the biopsy channel for correct removal of microorganisms. It was concluded that the reuse of enzyme detergent solutions contributed to the contamination of the endoscopes with potentially pathogenic microorganisms. It is necessary to re-evaluate institutional protocols, in order to comply with Anvisa's guidance through RDC nº. 55 of November 14, 2012 that enzymatic detergents should not be reused under loss of product efficiency. The physical characteristics of the enzymatic detergents must be observed by the health services according to the parameters established by the manufacturers.(AU)


Assuntos
Humanos , Controle de Infecções/métodos , Endoscópios/microbiologia , Detergentes/isolamento & purificação , Detergentes/normas , Pseudomonas/isolamento & purificação , Staphylococcus aureus/isolamento & purificação , Contenção de Riscos Biológicos , Dissertação Acadêmica , Enterobacter/isolamento & purificação , Enzimas , Escherichia coli/isolamento & purificação , Klebsiella/isolamento & purificação
4.
Rev. SOBECC ; 22(2): 106-114, abr.-jun 2017.
Artigo em Inglês, Português | LILACS, BDENF - Enfermagem | ID: biblio-848197

RESUMO

Objetivo: Identificar estudos que abordem indicações e limitações dos diferentes detergentes utilizados no processamento de produtos para a saúde. Método: Revisão integrativa que incluiu publicações presentes nas bases de dados Scientific Eletronic Library Online, Science Direct, Scopus, Web of Science e PubMed, no período de 2000 a 2016, nos idiomas inglês e português. Resultados: Foram identificados nove estudos. Os detergentes alcalinos apresentam boa remoção de sujidades, são indicados para uso em equipamento automatizado, adequados em processos que utilizem água dura e compatíveis com instrumentais cirúrgicos de aço inoxidável. Podem danificar o produto para a saúde e reagir com alumínio, zinco, metais não ferrosos, borracha e látex. Detergentes enzimáticos são compatíveis com diversos materiais e, devido à presença de enzimas, removem diferentes sujidades do instrumental. Conclusão: Embora os detergentes alcalino e enzimático possuam similaridades, a escolha do produto exige o conhecimento da sua ação, observando as características de uso, compatibilidade com o produto para a saúde e qualidade da água.


Objective: To identify studies that address indications and limitations of different detergents used in the processing of medical devices. Method: Integrative review that included publications in Scientific Electronic Library Online, Science Direct, Scopus, Web of Science and PubMed, from 2000 to 2016, in English and in Portuguese. Results: Nine studies were identified. Alkaline detergents remove dirt well, its use is indicated for automated equipment, and they are suitable in processes that use hard water, compatible with surgical stainless steel instruments. They may damage the medical device and react with aluminum, zinc, non-ferrous metals, rubber and latex. Enzymatic detergents are compatible with various materials and, due to the presence of enzymes, remove different types of dirt from the instrument. Conclusion: Although alkaline and enzymatic detergents present similarities, the choice of the product requires knowledge of its action, observing the characteristics of use, compatibility with the medical device and water quality.


Objetivo: Identificar los estudios que abordan indicaciones y limitaciones de diferentes detergentes utilizados en el procesamiento de productos de salud. Método: Revisión integrada que incluye publicaciones presentes en las bases de datos Scientific Electronic Library Online, Science Direct, Scopus, Web of Science y PubMed, de 2000 a 2016, en los idiomas Inglés y Portugués. Resultados: Se identificaron nueve estudios. Los detergentes alcalinos tienen buena eliminación de impurezas, están indicados para su uso en equipos automatizados, los procedimientos adecuados utilizando agua dura compatibles e instrumental acero inoxidable quirúrgico. Pueden dañar la salud del producto, y reaccionar con aluminio, zinc, metales no ferrosos, caucho y látex. Detergentes enzimáticos son compatible con diversos materiales y, debido a la presencia de enzimas, eliminan diferentes suciedades de los instrumentales. Conclusión: Aunque detergentes alcalinos y enzimáticos presenten similitudes, la elección del producto requiere el conocimiento de su acción, observando las características de uso, compatibilidad con el producto para la salud y la calidad del agua.


Assuntos
Humanos , Detergentes , Equipamentos e Provisões , Saneantes , Esterilização , Desinfecção , Eficácia
5.
Rev. latinoam. enferm ; 22(6): 1034-1040, 16/12/2014. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: lil-732956

RESUMO

OBJECTIVES: to identify the number of electro-medical pieces of equipment in a coronary care unit, characterize their types, and analyze implications for the safety of patients from the perspective of alarm fatigue. METHOD: this quantitative, observational, descriptive, non-participatory study was conducted in a coronary care unit of a cardiology hospital with 170 beds. RESULTS: a total of 426 alarms were recorded in 40 hours of observation: 227 were triggered by multi-parametric monitors and 199 were triggered by other equipment (infusion pumps, dialysis pumps, mechanical ventilators, and intra-aortic balloons); that is an average of 10.6 alarms per hour. CONCLUSION: the results reinforce the importance of properly configuring physiological variables, the volume and parameters of alarms of multi-parametric monitors within the routine of intensive care units. The alarms of equipment intended to protect patients have increased noise within the unit, the level of distraction and interruptions in the workflow, leading to a false sense of security. .


OBJETIVOS: identificar o número de alarmes dos equipamentos eletromédicos numa unidade coronariana, caracterizar o tipo e analisar as implicações para a segurança do paciente na perspectiva da fadiga de alarmes. MÉTODO: trata-se de estudo quantitativo observacional descritivo, não participante, desenvolvido numa unidade coronariana de um hospital de cardiologia, com capacidade para 170 leitos. RESULTADOS: registrou-se o total de 426 sinais de alarmes, sendo 227 disparados por monitores multiparamétricos e 199 alarmes disparados por outros equipamentos (bombas infusoras, hemodiálise, ventiladores mecânicos e balão intra-aórtico), nas 40h, numa média total de 10,6 alarmes/hora. CONCLUSÃO: os resultados encontrados reforçam a importância da configuração de variáveis fisiológicas, do volume e dos parâmetros de alarmes dos monitores multiparamétricos à rotina das unidades de terapia intensiva. Os alarmes dos equipamentos destinados a proteger os pacientes têm conduzido ao aumento do ruído na unidade, à fadiga de alarmes, a distrações e interrupções no fluxo de trabalho e à falsa sensação de segurança. .


OBJETIVOS: identificar el número de alarmas de los equipamientos electromédicos en una unidad coronariana, caracterizar el tipo y analizar las implicaciones para la seguridad del paciente en la perspectiva de fatiga de alarmas. MÉTODO: se trata de un estudio cuantitativo, observacional, descriptivo, no participante, desarrollado en una unidad coronariana de un hospital de cardiología, con capacidad de 170 camas. RESULTADOS: se registró un total de 426 señales de alarmas, siendo 227 disparadas por monitores multiparamétricos y 199 disparadas por otros equipamientos (bombas de infusión, hemodiálisis, ventiladores mecánicos y balón intraaórtico), durante 40h, con un promedio total de 10,6 alarmas/hora. CONCLUSIÓN: los resultados encontrados refuerzan la importancia de la configuración de las variables fisiológicas, del volumen y de los parámetros de alarma de los monitores multiparamétricos, a la rutina de las unidades de terapia intensiva. Las alarmas de los equipamientos destinados a proteger a los pacientes, han llevado al aumento del ruido en la unidad, a la fatiga de alarmas, a las distracciones e interrupciones en el flujo de trabajo y a una falsa sensación de seguridad. .


Assuntos
Humanos , RNA Polimerases Dirigidas por DNA/metabolismo , Proteínas Oncogênicas Virais/genética , RNA Polimerase III/metabolismo , Sarcosina/análogos & derivados , Fatores de Transcrição TFIII , Transcrição Gênica , Fatores de Transcrição/metabolismo , Proteínas Precoces de Adenovirus , Detergentes , Proteínas de Ligação a DNA/genética , Células HeLa , Cinética , Sarcosina/farmacologia , Fator de Transcrição TFIIIB , Fatores de Transcrição/genética , Transcrição Gênica/efeitos dos fármacos
6.
Rev. Esc. Enferm. USP ; 42(2): 282-289, jun. 2008. ilus, tab
Artigo em Português | LILACS, BDENF - Enfermagem | ID: lil-486527

RESUMO

Estudo de desenvolvimento metodológico que teve por objetivo construir um instrumento de avaliação de detergentes enzimáticos e analisar a ação dos produtos sobre os instrumentais. O instrumento foi submetido à análise de três juízes. O pré-teste foi realizado com 25 instrumentos. A amostra para a análise de campo foi constituída por mais 25 instrumentais cirúrgicos. Os resultados obtidos permitiram a construção de um instrumento com 19 itens e a análise de campo constatou que houve diferenças nos escores das soluções avaliadas. O produto P5 obteve a melhor média 78,7 (DP 6,68) e mediana 80,2 e o produto P4 obteve o pior desempenho, média 56,2 (DP 7,09) e mediana 56,7, em um intervalo possível de 19 a 95. O instrumento de medida mostrou-se confiável ao estudo, apresentando valor do Alpha de Cronbach de 0,83.


The objective of this study was to develop an instrument for measuring the quality of enzymatic detergents and analyze their cleaning action on surgical instruments. The instrument was submitted to a panel of three judges. It was pre-tested in a sample of 25 surgical instruments. Twenty-five other surgical instruments trays were used for the field analysis. The results made possible the construction of an instrument with 19 items, and the field analysis verified that there were differences in the scores of the solutions that were evaluated. P5 had the best average score, 78.7 (SD 6.68), and median of 80.2, and P4 had the worst performance, with an average score of 56.2 (SD 7.09) and median of 56.7 in a possible range between 19 and 95. In the study, the measuring instrument proved to be reliable, with a Cronbach's alpha of 0.83.


Se trata de un estudio de desarrollo metodológico que tuvo como objetivo construir un instrumento de evaluación de detergentes enzimáticos y analizar la acción de los productos sobre los instrumentales. El instrumento fue sometido al análisis de tres jueces. El pre test fue realizado con 25 instrumentos. La muestra para el análisis de campo estuvo constituida por más de 25 instrumentales quirúrgicos. Los resultados obtenidos permitieron la construcción de un instrumento con 19 items y por el análisis de campo se constató que hubo diferencias en los escores de las soluciones evaluadas. El producto P5 obtuvo el mejor pro-medio de 78,7 (DP 6,68) y mediana de 80,2 y el producto P4 obtuvo el peor desempeño, promedio de 56,2 (DP 7,09) y mediana de 56,7, en un intervalo posible de 19 a 95. El instrumento de medida se mostró confiable para el estudio, presentando valor del Alpha de Cronbach de 0,83.


Assuntos
Detergentes , Inquéritos e Questionários , Esterilização , Instrumentos Cirúrgicos , Enzimas