Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
J. optom. (Internet) ; 17(3): [100505], jul.-sept2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-231869

RESUMO

Purpose: This study explored whether retinoscopy (RET) provides comparable results of relative peripheral refraction (RPR) to open–field autorefractometry (AR) in myopic subjects.Methods: Peripheral refraction was measured in 20 myopic and 20 control adult subjects. Both central and peripheral refraction (20° nasal and temporal eccentricity) were measured using RET and open-field AR. Differences in the median central spherical equivalent (SE), median RPR, and median J45/J180 power vectors between the RET and AR techniques were analyzed. Moreover, Bland – Altman plots were used to assess the agreement between RET and AR methods for RPR measurements in MG. Results: For MG, the median RPR values were positive (hyperopic shift), and no significant differences were observed between the RET and AR techniques with respect to RPR measurement. In addition, we did not observe any significant differences in the RPR values between the nasal and temporal eccentricities for either the RET or AR technique for myopic subjects. There was also a significant correlation and agreement between the RET and AR technique for RPR measurements. With respect to central refraction, the median SE was slightly more positive for the RET than for the AR technique. Inside the CG, we also found significant correlation between the RET and AR technique for RPR measurements, and we observed a myopic shift in peripheral eccentricities. Conclusion: Our results show that retinoscopy may be a useful tool for objective measurements of RPR in myopic subjects and may be used interchangeably with the open-field AR method in everyday clinical practice. (AU)


Assuntos
Humanos , Retinoscopia , Miopia , Refração Ocular , Visão Ocular , Visão Binocular , Oftalmologistas
2.
J. optom. (Internet) ; 17(3): [100497], jul.-sept2024. graf, tab
Artigo em Inglês | IBECS | ID: ibc-231871

RESUMO

Purpose: To compare the eye defocus curves (DCs) obtained with stimuli on red, green, and white backgrounds and to investigate the applicability of the duochrome test (DT) in different age groups. Methods: 12 elderly (ELD: 59.3 ± 3.9 years) and 8 young (YG: 22.1 ± 1.1 years) subjects were recruited. An optometric assessment with the DT was carried out to obtain the subjective refraction at distance. DCs at distance on green, white, and red backgrounds were measured and the following parameters were deduced: dioptric difference between red-green, green-white, red-white focal positions (minima of the DCs), best corrected visual acuity (BCVA), and widths of the DCs for red, green, and white. Results: The DC difference between the green-white focal positions (mean ± standard deviation) was -0.12±0.17 diopters (D) (ELD, p = 0.012) and -0.11±0.12 D (YG, p = 0.039), while the red-white difference was not statistically significant. The DC red-green difference was 0.20±0.16 D (ELD, p = 0.002) and 0.18±0.18 D (YG, p = 0.008). The ELD BCVA with green background was significantly worse than BCVA with red (p = 0.007) and white (p = 0.007). The mean value of the DC's width in ELD for green (1.01±0.36 D) was higher than for red (0.77±0.21 D) and for white (0.84±0.35 D), but with no statistical significance. Conclusion: Both age groups showed a slight focusing preference for red when using white light. Moreover, ELD showed a worse BCVA with a green compared to a red background. Despite these results deduced by DC analyses, these aspects do not compromise the possibility of using the DT in clinical practice both in the young and in the elderly. Furthermore, the difference of about 0.20 D between red-green DC in both groups confirms the clinical appropriateness of the widespread use of 0.25 D step as the standard minimum difference in power between correcting lenses.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Idoso , Visão Ocular , Acuidade Visual , Fundo de Olho , Lentes de Contato , Testes Visuais
3.
J. optom. (Internet) ; 17(3): [100510], jul.-sept2024. tab
Artigo em Inglês | IBECS | ID: ibc-231872

RESUMO

Purpose: To evaluate the association between visual symptoms and use of digital devices considering the presence of visual dysfunctions. Methods: An optometric examination was conducted in a clinical sample of 346 patients to diagnose any type of visual anomaly. Visual symptoms were collected using the validated SQVD questionnaire. A threshold of 6 hours per day was used to quantify the effects of digital device usage and patients were divided into two groups: under and above of 35 years old. A multivariate logistic regression was employed to investigate the association between digital device use and symptoms, with visual dysfunctions considered as a confounding variable. Crude and the adjusted odds ratio (OR) were calculated for each variable. Results: 57.02 % of the subjects reported visual symptoms, and 65.02% exhibited some form of visual dysfunction. For patients under 35 years old, an association was found between having visual symptoms and digital device use (OR = 2.10, p = 0.01). However, after adjusting for visual dysfunctions, this association disappeared (OR = 1.44, p = 0.27) and the association was instead between symptoms and refractive dysfunction (OR = 6.52, p < 0.001), accommodative (OR = 10.47, p < 0.001), binocular (OR = 6.68, p < 0.001) and accommodative plus binocular dysfunctions (OR = 46.84, p < 0.001). Among patients over 35 years old, no association was found between symptoms and the use of digital devices (OR = 1.27, p = 0.49) but there was an association between symptoms and refractive dysfunction (OR = 3.54, p = 0.001). Conclusions: Visual symptoms are not dependent on the duration of digital device use but rather on the presence of any type of visual dysfunction: refractive, accommodative and/or binocular one, which should be diagnosed.(AU)


Assuntos
Humanos , Masculino , Feminino , Visão Ocular , Testes Visuais , Campos Visuais , Pessoas com Deficiência Visual , Visão Binocular , Inquéritos e Questionários , Optometria
4.
J. optom. (Internet) ; 17(3): [100491], jul.-sept2024. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-231873

RESUMO

Background and objectives: The invention described herein is a prototype based on computer vision technology that measures depth perception and is intended for the early examination of stereopsis. Materials and methods: The prototype (software and hardware) is a depth perception measurement system that consists on: (a) a screen showing stereoscopic models with a guide point that the subject must point to; (b) a camera capturing the distance between the screen and the subject's finger; and (c) a unit for recording, processing and storing the captured measurements. For test validation, the reproducibility and reliability of the platform were calculated by comparing results with standard stereoscopic tests. A demographic study of depth perception by subgroup analysis is shown. Subjective comparison of the different tests was carried out by means of a satisfaction survey. Results: We included 94 subjects, 25 children and 69 adults, with a mean age of 34.2 ± 18.9 years; 36.2 % were men and 63.8 % were women. The DALE3D platform obtained good repeatability with an interclass correlation coefficient (ICC) between 0.94 and 0.87, and coefficient of variation (CV) between 0.1 and 0.26. Threshold determining optimal and suboptimal results was calculated for Randot and DALE3D test. Spearman's correlation coefficient, between thresholds was not statistically significant (p value > 0.05). The test was considered more visually appealing and easier to use by the participants (90 % maximum score). Conclusions: The DALE3D platform is a potentially useful tool for measuring depth perception with optimal reproducibility rates. Its innovative design makes it a more intuitive tool for children than current stereoscopic tests. Nevertheless, further studies will be needed to assess whether the depth perception measured by the DALE3D platform is a sufficiently reliable parameter to assess stereopsis.(AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto Jovem , Visão Binocular , Percepção de Profundidade , Visão Ocular , Testes Visuais
5.
J. optom. (Internet) ; 17(3): [100508], jul.-sept2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-231874

RESUMO

Purpose: To report the visual and refractive characteristics and the prevalence of amblyopia in patients with different types of Duane's Retraction Syndrome (DRS). Method: This retrospective study was performed on hospital records of 582 DRS patients at Farabi Hospital, Iran, from 2012 to March 2022. Results: The mean age of patients was 19.4 ± 11.9 (range, 3–70) years [335 (57.6 %) females and 247 (42.4 %) males (P < .001)]. DRS type I, II, III, and IV were presented in 347 (59.6 %), 148 (25.4 %), 82 (14.1 %), and 5 (0.9 %) patients, respectively. There were 530 (91.1 %) patients with unilateral and 52 (8.9 %) with bilateral involvement. In the unilateral patients, the DRS eyes' corrected distance visual acuity (CDVA) and astigmatism were significantly worse than the Non-DRS Eyes (P < .001). The mean amount of all refractive and visual parameters in bilateral patients' right or left eyes was significantly lower than in unilateral patients' non-DRS eyes (all P < .05). Anisometropia was observed in 75(12.9 %) of the patients. Amblyopia was observed in 18.5 % (98 patients) and 36.5 % (19 patients) of unilateral and bilateral DRS patients, respectively (P < .001). In unilateral patients, amblyopia was found in 57 (16.4 %) patients with Type I, 22 (14.9 %) patients with Type II, 16 (19.5 %) patients with Type III, and 3 (60 %) patients with Type IV. Forty-four (37.6 %) of patients with amblyopia had anisometropia. Conclusion: This large-scale study indicates that DRS types differ in terms of refractive error, visual acuity, and the prevalence of amblyopia and anisometropia. Clinicians should be aware of the clinical features associated with different types of DRS.(AU)


Assuntos
Humanos , Masculino , Feminino , Visão Ocular , Ambliopia , Síndrome da Retração Ocular , Erros de Refração , Anisometropia
6.
J. optom. (Internet) ; 17(3): [100512], jul.-sept2024. graf, tab
Artigo em Inglês | IBECS | ID: ibc-231875

RESUMO

Purpose: In children under 20 years, refractive development targets a cycloplegic refractive error of +0.5 to +1.5D, while presbyopes over 40 years generally have non-cycloplegic errors of ≥ +1D. Some papers suggest these periods are separated by a period of myopic refractive error (i.e., ≤ –0.50D), but this remains unclear. Hence, this work investigates the mean cycloplegic refractive error in adults aged between 20 – 40 years. Methods: In 2002 a cross-sectional study with stratified cluster sampling was performed on the population of Tehran, providing cycloplegic and non-cycloplegic refractive error data for the right eyes of 3,576 participants, aged 30.6 ± 18.6 years (range: 1–86 years). After grouping these data into age groups of 5 years, the refractive error histogram of each group was fitted to a Bigaussian function. The mean of the central, emmetropized peak was used to estimate the mean refractive error without the influence of myopia. Results: The mean cycloplegic refractive error at the emmetropized peak decreased from +1.10 ± 0.11D (95 % confidence interval) to +0.50 ± 0.04D before 20 years and remains stable at that value until the age of 50 years. The non-cycloplegic refractive error also sees a stable phase at 0.00 ± 0.04D between 15 – 45 years. After 45 – 50 years both cycloplegic and non-cycloplegic refractive error become more hypermetropic over time, +1.14 ± 0.12D at 75 years. Conclusions: The cycloplegic refractive error in adults is about +0.50D between 20 – 50 years, disproving the existence of the myopic period at those ages.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Visão Ocular , Testes Visuais , Erros de Refração , Emetropia , Estudos Transversais , Irã (Geográfico)
10.
J. optom. (Internet) ; 17(2): [100485], Abr-Jun, 2024. tab, ilus
Artigo em Inglês | IBECS | ID: ibc-231620

RESUMO

Purpose: To study topographic epithelial and total corneal thickness changes in myopic subjects undergoing successful orthokeratology treatment in connection with the objective assessment of contact lens decentration. Methods: A prospective-observational and non-randomized study in 32 Caucasian myopic eyes undergoing Ortho-k for 3 months. Total, epithelial, and stromal thicknesses were studied before and after Ortho-k treatment, using optical coherence tomography with anterior segment application software. Central, paracentral, and mid-peripheral values are taken along 8 semi-meridians. Results: The central average total corneal thickness was 4.72 ± 1.04 μm thinner after Ortho-K. The paracentral corneal thickness showed no significant changes (p = 0.137), while the mid-peripheral corneal thickness was increased by 3.25 ± 1.6 μm associating this increase exclusively to the epithelial plot (p<0.001). When lens centration was assessed, a lens fitting decentration less than 1.0 mm was found for the whole sample, predominantly horizontal-temporal (87.5%) and vertical-inferior (50%) decentring. Corneal topographical analysis revealed a horizontal and vertical epithelial thickness asymmetric change profile with paracentral temporal thinnest values, and mid-peripheral nasal thickest values. Conclusions: The present study found a central corneal thinning induced by Ortho-k lenses in subjects with moderate myopia, only associated with a change in epithelial thickness, as well as mid-peripheral thickening, that seems to be mainly epithelial in origin. The authors also found a tendency of contact lens decentration toward temporal and inferior areas conditioning an asymmetric epithelial redistribution pattern.(AU)


Assuntos
Humanos , Masculino , Feminino , Visão Ocular , Miopia , Cristalino , Procedimentos Ortoceratológicos , Substância Própria , Tomografia de Coerência Óptica , Estudos Retrospectivos , Optometria , Oftalmologia , Estudos Prospectivos
11.
J. optom. (Internet) ; 17(2): [100492], Abr-Jun, 2024. tab
Artigo em Inglês | IBECS | ID: ibc-231621

RESUMO

Purpose: Given the increase in demand for optometry services by society and the importance of the Optometry profession in Portugal and Spain, the objective of this study was to determine job satisfaction and important factors related to this satisfaction in a sample of Portuguese and Spanish optometrists. Methods: A prospective, cross-sectional, and observational study was carried out from June to December 2021. An adaptation of the 15-item job satisfaction in eye-care personnel (JSEP) questionnaire validated by Paudel et al. was administered to Portuguese and Spanish optometrists. The questionnaire was shared through different social media (Facebook, LinkedIn, WhatsApp, etc.) in a Google form during the months of June to December 2021 in Portugal and Spain. Results: A total of 530 surveys were collected in Portugal (42.3%; n = 224) and Spain (57.7%; n = 306). The factors that most influence overall job satisfaction are salary, career development opportunities, recognition/prestige in society, good work-life balance (all p<0.001), workplace equipment and facilities, and encouragement reward positive feedback (both p = 0.002). When comparing the determinants of job satisfaction of optometrists, it was found that Portuguese professionals were generally more satisfied than Spanish ones (p<0.001). However, Spanish optometrists reported feeling more supported by their colleagues (p<0.001). Conclusion: This study has shown that the level of job satisfaction was higher in Portugal than in Spain. The most important factors influencing job satisfaction were salary, job stability, and support from colleagues.(AU)


Assuntos
Humanos , Masculino , Feminino , Satisfação no Emprego , Visão Ocular , Optometristas , Optometria , Espanha , Portugal , Estudos Prospectivos , Estudos Transversais , Inquéritos e Questionários
12.
J. optom. (Internet) ; 17(2): [100489], Abr-Jun, 2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-231622

RESUMO

Purpose: The impact of visual outcomes of cataract surgery can be measured using a questionnaire. The aim of our study was to evaluate how patient quality of life changes after cataract surgery and if there are differences between the responses of patients with nuclear, cortical, and posterior subcapsular cataracts, which has not been studied before. Method: We studied 210 cataract patients who were divided into 3 cataract groups based on their cataract type: nuclear (n = 80), cortical (n = 70), and posterior subcapsular (PSC) (n = 60). The patients completed the Visual Function Index (VF-14) questionnaire before, 2 weeks and 1 month after bilateral cataract surgery. The results were analysed using one-way ANOVA (significance level 5 %) and were compared over time and between the cataract groups. Results: Before the cataract surgery, cortical cataract patients had the lowest questionnaire score compared to nuclear and posterior subcapsular cataract groups (p = 0.08). After cataract surgery, cortical cataract patients experienced the greatest improvement in near distance daily activities, while PSC cataract patients experienced the greatest improvement in far distance daily activities (p = 0.38). Before surgery, nuclear cataract patients had the highest questionnaire scores compared to the other cataract groups (p = 0.08). Conclusion: At the 1 month follow-up, there were no statistically significant differences in questionnaire scores between the cataract groups for any of the questions. Overall, cortical cataract patients showed a trend to experience the greatest subjective improvement in quality of life after cataract removal, followed by nuclear and posterior subcapsular patients.(AU)


Assuntos
Humanos , Masculino , Feminino , Catarata/reabilitação , Extração de Catarata , Visão Ocular , Qualidade de Vida , Catarata/classificação , Inquéritos e Questionários , Optometria
13.
J. optom. (Internet) ; 17(2): [100488], Abr-Jun, 2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-231623

RESUMO

Purpose: As ocular dryness and glaucoma are more prevalent with increasing age, understanding how the tear film affects tonometry is important. The present study aims to understand the impact that changes in the tear film have on intraocular pressure (IOP), corneal hysteresis, and corneal resistance factor measurements. Methods: Cross-sectional research was conducted and 37 patients were assessed. The tear film lipid layer and the non-invasive break-up time (NIBUT) were evaluated using the Tearscope Plus (Keeler, Windsor, UK). Dry eye symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. IOP was measured using rebound tonometry and the Ocular Response Analyzer (ORA, Reichert). Corneal biomechanical properties were measured using ORA. Results: It was found that an increase in the IOP measured with the iCare was directly correlated with the subclass that evaluated symptomatology associated with environmental factors (r = 0.414, p<0.05, Spearman). Goldmann-correlated IOP (IOPg) and Corneal-compensated IOP (IOPcc) values were statistically significantly different between the various interferometric patterns (p<0.05). It was also found that an increase in the corneal biomechanical properties measured with ORA was directly correlated with the overall scores obtained when using the OSDI and some of its subclasses. Conclusions: Tear film interferometric patterns were shown to have some impact on the IOP measured using ORA. The IOP measured with iCare seems to be related to the symptomatology obtained from OSDI. Corneal biomechanical properties were related to the OSDI total score and some of its subclasses. An increase in symptomatology was associated with an increase in the measured biomechanical properties of the cornea.(AU)


Assuntos
Humanos , Masculino , Feminino , Optometria , Aparelho Lacrimal , Visão Ocular , Síndromes do Olho Seco , Glaucoma , Pressão Intraocular
14.
J. optom. (Internet) ; 17(2): [100500], Abr-Jun, 2024. tab
Artigo em Inglês | IBECS | ID: ibc-231624

RESUMO

Purpose: Visual snow syndrome (VSS) is a complex neurological condition presenting with an array of sensory, motor, and perceptual dysfunctions and related visual and non-visual symptoms. Recent laboratory studies have found subtle, basic, saccadic-based abnormalities in this population. The objective of the present investigation was to determine if saccadic-related problems could be confirmed and extended using three common clinical reading-related eye movement tests having well-developed protocols and normative databases. Methods: This was a retrospective analysis of 32 patients (ages 16–56 years) diagnosed with VSS in the first author's optometric practice. There was a battery of three reading-related tests: the Visagraph Reading Eye Movement Test, the Developmental Eye Movement (DEM) Test, and the RightEye Dynamic Vision Assessment Test, all performed using their standard documented protocols and large normative databases. Results: A high frequency of oculomotor deficits was found with all three tests. The greatest percentage was revealed with the Visagraph (56%) and the least with the RightEye (23%). A total of 77% of patients failed at least one of the three tests. Conclusion: The present findings confirm and extend earlier investigations revealing a high frequency of saccadic-based oculomotor problems in the VSS population, now including reading-related tasks. This is consistent with the more general oculomotor/motor problems found in these individuals.(AU)


Assuntos
Humanos , Masculino , Feminino , Doenças do Sistema Nervoso Central/complicações , Visão Ocular , Oftalmoplegia , Optometria , Movimentos Oculares
15.
J. optom. (Internet) ; 17(2): [100502], Abr-Jun, 2024. graf
Artigo em Inglês | IBECS | ID: ibc-231625

RESUMO

Background: Silicone oil is used as endotamponade following vitreoretinal surgery to maintain the retina reattached when indicated. This study investigates the hypothesis that silicone oil causes insulation effects on the retina by affecting its response to light. Methods: Electrophysiological responses to a flash stimulus were recorded using full-field electroretinography (ERG) and visual evoked potentials (VEP). Recordings were performed in 9 patients who underwent surgery for retinal detachment, before (1–2 days) and after (2–3 weeks) silicone oil removal (SOR) in both the study and the control eye. Flash ERG and VEP recordings were performed according to the ISCEV standard protocol. Results: Statistically significant differences were found in the study eye in the amplitudes of the ERG responses and their corresponding ratios, i.e. the amplitude after SOR over the amplitude before SOR, in all conditions tested. No differences were observed in the control eye. The mean ratio of photopic ERG response was 3.4 ± 2.4 for the study and 1.0 ± 0.3 for the control eye (p<0.001). The mean ratio of ERG flicker response was 3.1 ± 2.4 and 1.0 ± 0.3, respectively (p = 0.003). Scotopic flash ERG ratio was 5.0 ± 4.4 for the study and 1.3 ± 0.6 for the control eye (p = 0.012). No differences were observed for the amplitude and latency of flash VEP response after SOR. Conclusions: Silicone oil causes a reduction in flash ERG responses; no effect was found on flash VEP responses. ERGs in eyes filled with silicone oil should not be considered representative of retinal functionality, in contrast to VEPs, which are not affected by silicone oil presence.(AU)


Assuntos
Humanos , Masculino , Feminino , Descolamento Retiniano/cirurgia , Óleos de Silicone/administração & dosagem , Óleos de Silicone/efeitos adversos , Eletrorretinografia , Cirurgia Vitreorretiniana , Optometria , Visão Ocular , Retina/cirurgia , Potenciais Evocados Visuais
16.
Arch. Soc. Esp. Oftalmol ; 99(3): 91-97, Mar. 2024. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-231135

RESUMO

Detectar y caracterizar los defectos del campo visual (CV) mediante perimetría Octopus en pacientes con glaucoma congénito primario (GCP) y determinar la calidad y duración del CV. Material y métodos: Se incluyeron 88 ojos de 70 pacientes diagnosticados de GCP. Las evaluaciones se realizaron con un Octopus 900 y cada ojo se evaluó con el algoritmo de perimetría orientada por tendencias (G-TOP). Se recogieron datos cuantitativos de CV: datos de calidad (respuestas falsa positiva y negativa, y duración del tiempo) y resultados de desviación media (DM) y raíz cuadrada de la varianza de pérdida (sLV). También se recogieron datos cualitativos: presencia de defectos difusos y localizados, hemicampo afectado y grado de defectos utilizando la clasificación de Aulhorn y Karmeyer. Se analizaron las correlaciones entre los resultados perimétricos y las variables clínicas. Resultados: La mediana de edad fue de 11 (8-17) años. El 65,9% (58/88) de los ojos con GCP presentaban defectos de CV. Se observaron defectos difusos en 10/58 ojos (16,94%) (DM media=23,92 [DE: 2,52]) dB) y defectos localizados en 48/58 ojos (82,75%). El defecto más frecuente fue el escotoma incipiente paracentral (n=15), el escalón nasal (n=8), el defecto arciforme añadido (n=2), el semianular (n=13) y el defecto concéntrico con isla central (n=9). El hemicampo visual afectado con mayor frecuencia fue el inferior. La duración media de la prueba fue de 2min 12s (DE: 21,6s). Los valores MD y sLV se correlacionaron con la agudeza visual mejor corregida, la relación excavación/disco y el número de cirugías de glaucoma (todas p<0,001). Conclusión: Se identificó un alto número de defectos difusos y localizados utilizando la perimetría Octopus en pacientes con GCP. El defecto más frecuente fue el escotoma paracentral, y el hemicampo inferior fue el más afectado.(AU)


Purpose: To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration. Material and methods: Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed. ResultsMedian age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD=23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n=15), nasal step (n=8), adding arcuate defect (n=2), half ring-shaped (n=13) and concentric defect with a central island (n=9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2min 12s (SD: 21.6s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all P<.001). Conclusion: A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.(AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Glaucoma , Testes de Campo Visual/métodos , Cegueira , Anormalidades do Olho , Oftalmologia , Pediatria , Visão Ocular
17.
J. optom. (Internet) ; 17(1)Jan.-March. 2024.
Artigo em Inglês | IBECS | ID: ibc-229114

RESUMO

Purpose To compare improvements in visual acuity (VA) and stereoacuity between active vision therapy (AVT) and conventional patching therapy in children with amblyopia. Methods This study included 65 children aged 5 to 16 years (mean age±SD, 11.00±3.29 years) with unilateral amblyopia. Among them, 31 children underwent active vision therapy (AVT group), and 34 children underwent conventional patching therapy (patching group). AVT group underwent three sequential phases of AVT: Monocular phase (pursuit, saccades, fixation, visuomotor, eye-hand coordination, and central peripheral activities), biocular phase (diplopia awareness, antisuppression, monocular fixation in a binocular field, accommodative activities, bilateral integration, and fine motor activities) and binocular phase (fusion and stereopsis). Patching group patched their fellow eyes as per guidelines by Pediatric Eye Disease Investigator Group. Best-corrected monocular VA and stereoacuity were measured at baseline and after three months of therapy in both groups. Results There were significant improvements in the mean acuities in amblyopic eye (AE) in both AVT (0.32±0.11 logMAR, p <0.001) and patching groups (0.27±0.19 logMAR, p ˂ 0.001). However, there was no significant difference in mean acuity gains in AE between AVT and patching groups (p = 0.059). Mean gains in stereoacuities (log seconds of arc) were statistically significant in both AVT (0.81±0.34, p < 0.001) and patching groups (0.32±0.34, p < 0.001). The stereoacuity gain in the AVT group was significantly higher compared to patching group (p < 0.001). Conclusion Active vision therapy had a better impact than conventional patching therapy in terms of improvement of stereoacuity but not in terms of VA when used for treating children with amblyopia. (AU)


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Acuidade Visual , Ambliopia/terapia , Testes do Emplastro/métodos , Percepção Visual , Visão Ocular
18.
J. optom. (Internet) ; 16(4): 277-283, October - December 2023. tab, graf
Artigo em Inglês | IBECS | ID: ibc-225617

RESUMO

Purpose: To compare the performance in the Developmental Eye Movement test (DEM) and the Test of Visual Perceptual Skills (TVPS) between three groups: individuals with strabismus and amblyopia, patients with binocular and accommodative dysfunctions, and subjects with normal binocular and accommodative function. Methods: A multicentric, retrospective study including 110 children aged 6–14 years old was conducted to investigate the potential impact of strabismus, amblyopia, and different binocular conditions in DEM results (adjusted time in vertical and horizontal parts) and TVPS (percentiles in the seven sub-skills). Results: No significant differences were found in the different subtests of the vertical and horizontal DEM and all the sub-skills in the TVPS between the three groups of the study. We found high variability of performance in the DEM test between participants with strabismus and amblyopia compared with binocular and accommodative problems. Conclusion: DEM and TVPS scores have not been found to be influenced by the presence of strabismus with or without amblyopia, nor by binocular and accommodative dysfunctions. A slightly correlation tendency with horizontal DEM and degree of exotropia deviation was observed. (AU)


Assuntos
Humanos , Criança , Adolescente , Estrabismo/diagnóstico , Ambliopia/diagnóstico , Medições dos Movimentos Oculares , Percepção Visual/fisiologia , Estudos Retrospectivos , Estudos Multicêntricos como Assunto , Visão Ocular
19.
J. optom. (Internet) ; 16(3): 189-198, July - September 2023. tab, graf
Artigo em Inglês | IBECS | ID: ibc-222227

RESUMO

Purpose This study aimed to translate the Convergence Insufficiency Symptom Survey (CISS) into the Italian language and assess psychometric properties of the translated questionnaire (CISS_I). Methods The CISS_I was arranged according to guidelines for a comprehensive multistep methodologic process for translating, adapting, and validating psychometric instruments in health care research. The CISS_I questionnaire was administered to 103 volunteers (21.8 ± 2.2 years), students in higher education, at two different times. A complete optometric evaluation was performed including subjective refraction, best corrected visual acuity, near point of convergence, prism fusional ranges to blur, diplopia and recovery, TNO stereo test and prism cover test for measurement of heterophoria. Results The performance of the CISS_I in terms of validity showed some points of weakness. Sensitivity was 42%, specificity was 74%, positive predictive value was 27% and negative predictive value was 85%. The area under the ROC curve was 0.672. On the contrary, the results showed good internal consistency of the CISS_I (Cronbach's alpha - α=0.89) and good test-retest reliability (ICC = 0.92). Rasch analysis showed good model fit (all items, except one, with infit and outfit mean square between 0.7 and 1.3), good measurement precision (person separation = 2.66) and good targeting –0,81 logits but also some evidence of multidimensionality. Conclusions The CISS_I showed some point of weakness in terms of validity but also good psychometric properties and has been shown to be applicable to an Italian speaking population to quantify the visual discomfort associated with near vision in higher education students. The results show that high CISS_I score is not necessarily linked to convergence insufficiency, while low scores can exclude the presence of this anomaly...(AU)


Assuntos
Humanos , Adulto Jovem , Transtornos da Motilidade Ocular , Avaliação de Sintomas , Visão Ocular , Inquéritos e Questionários , Tradução
20.
J. optom. (Internet) ; 16(2): 91-99, Abr-Jun 2023. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-218460

RESUMO

Purpose: We aimed to determine if visual acuity (VA) could differentiate the quality of vision with two ophthalmic lenses with unwanted astigmatism. Methods: Twenty presbyopic subjects (48 to 62 years old; VA better than 0.0 logMAR) graded the magnitude of their preference between two progressive addition lenses (plano addition 2.00D) and their visual acuities were measured with both lenses at various eccentricities from -12 to +12 mm from the near vision point every 3 mm in controlled conditions. Results: The Lens with the least peripheral astigmatism was preferred by 75% of the subjects. VA measured at the near vision point was statistically worse (p<0.01) with this lens whereas the contrary was observed in the periphery (± 12 and -9 mm of eccentricity). The Friedman test shows that the eccentricity (p<0.001) has a significant effect on visual acuity. However, the lens did not show any significant effect (p=0.76). The choice of the favorite lens was predicted for only 35% when considering central VA (up to 6mm) and 80% of the subjects when considering peripheral VA (9 to 12mm). However, the magnitude of the difference could be predicted by peripheral VA in only 60% of the subjects. Conclusion: High contrast Visual acuity was clearly able to differentiate the 2 lens designs tested in our experiment. However, even under the controlled conditions of this study, it was not possible to predict the quality of vision, as measured by a subjective appreciation, through progressive addition lenses at various eccentricities from the near vision with an addition of 2.0D.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Acuidade Visual , Lentes de Contato , Visão Ocular , Optometria , Oftalmologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...