Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 429
Filtrar
1.
Apunts, Med. esport (Internet) ; 59(221)Jan.-Mar. 2024. tab, ilus
Artigo em Inglês | IBECS | ID: ibc-231118

RESUMO

There is little information regarding the acute repercussions of anterior cruciate ligament (ACL) reconstruction on muscle activation, especially on the proximal hip muscles. Thus, this study analyzed the acute effects of ACL reconstruction with doubled semitendinosus/gracilis (ST/G) autografts on lower limb muscle activation. Fourteen male recreational athletes that presented a primary unilateral ACL rupture and underwent the ACL reconstruction with an ST/G graft. Surface electromyographic (sEMG) signal were recorded from each participant during the maximal voluntary isometric contraction (MVIC) of the gluteus maximus and gluteus medius, vastus lateralis and vastus medialis, semitendinosus, biceps femoris, and medial gastrocnemius muscles and also during bipodal mini-squatting with open and closed eyes, before surgery and 15 days postoperatively. (sEMG) signal were normalized to isometric peak electromyography. The postoperative assessment showed reduced muscle activation in the gluteus maximus (p = 0.013, d:0.48) in non-operated limb and also in the muscle gluteus medius (p = 0.013, d:0.79), vastus medialis (p = 0.035, d:0.63) semitendinosus (p = 0.001, d:2.46), biceps femoris (p<0.001, d:1.5), and medial gastrocnemius (p = 0.001, d:1.45) during MVIC in the operated limb. The postoperative assessment also revealed alterations in the sEMG activity of the hip and local thigh muscles in the operated and non-operated limbs during mini-squatting with opened eyes and closed eyes (p<0.05). ACL reconstruction surgery with a doubled ST/G autograft may promote immediate changes in lower limb muscle activation of the operated and non-operated limb. (AU)


Assuntos
Humanos , Masculino , Adulto Jovem , Adulto , Lesões do Ligamento Cruzado Anterior/reabilitação , Reconstrução do Ligamento Cruzado Anterior , Fenômenos Biomecânicos , Eletromiografia , Traumatismos em Atletas/reabilitação , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/reabilitação
2.
Rev. esp. enferm. dig ; 115(12): 693-699, Dic. 2023. ilus, tab, graf
Artigo em Inglês, Espanhol | IBECS | ID: ibc-228704

RESUMO

Antecedentes: la esofagitis eosinofílica (EEo) activa se asocia a alteraciones en el calibre, la distensibilidad y la motilidad esofágica que podrían revertir con el tratamiento. Objetivos: estudiar el diámetro, la distensibilidad y la contractilidad esofágica en sujetos sanos comparándolos con pacientes con EEo antes y después del tratamiento. Métodos: estudio cuasiexperimental. Mediante EndoFLIP™, se analizaron el cuerpo esofágico y la unión esofagogástrica (UEG) de los tres grupos, y se diseñó un programa para obtener los valores de diámetro, distensibilidad y contractilidad esofágica. Resultados: incluimos diez voluntarios sanos (24-61 años, seis hombres) y nueve pacientes con EEo (21-52 años, siete hombres). El índice de distensibilidad de la UEG fue de 5,07 mm2/Hg en controles, 2,40 mm2/Hg en EEo antes del tratamiento y 2,46 mm2/Hg después; la meseta de distensibilidad fue de 20,02 mm, 15,43 mm y 17,41 mm, respectivamente; y el diámetro, de 21,90 mm, 17,73 mm y 18,30 mm, con diferencias significativas (p < 0,05) excepto entre los diámetros de controles y pacientes tratados (p = 0,079). Las contracciones anterógradas repetitivas aparecieron en el 90 % de los controles, en el 66,7 % de EEo a antes del tratamiento y en el 88,9 % después (p > 0,05). Conclusiones: el índice de distensibilidad de la UEG, la meseta de distensibilidad y el diámetro en controles son mayores que en pacientes, aunque seis semanas de tratamiento parece poco tiempo para ver cambios significativos en la biomecánica esofágica. Las contracciones anterógradas repetitivas son el patrón predominante en sanos y en EEo. Aportamos valores de normalidad de la biomecánica esofágica medida mediante planimetría por impedancia en nuestro entorno.(AU)


Background: active eosinophilic esophagitis is associated with esophageal caliber, distensibility and motility changes that may be reversed with treatment. Objectives: to study esophageal diameter, distensibility and contractility in healthy subjects compared to patients with eosinophilic esophagitis, both before and after treatment. Methods: a quasi-experimental study, EndoFLIP™, was used to analyze the esophageal body and esophago-gastric junction (EGJ) in all three groups, and a program was designed to obtain esophageal diameter, distensibility and contractility values. Results: ten healthy volunteers (24-61 years, six men) and nine patients with eosinophilic esophagitis (21-52 years, seven men) were included. The esophagogastric junction distensibility index was 5.07 mm2/Hg in the control subjects, 2.40 mm2/Hg in the subjects with eosinophilic esophagitis before treatment and 2.46 mm2/Hg after treatment. The distensibility plateau was 20.02 mm, 15.43 mm and 17.41 mm, respectively, and the diameter was 21.90 mm, 17.73 mm and 18.30 mm, showing significant differences (p < 0.05), except between control subjects and patients after treatment (p = 0.079). Repetitive antegrade contractions developed in 90 % of control subjects, 66.7 % of eosinophilic esophagitis patients before treatment and 88.9 % of the latter after treatment (p > 0.05). Conclusions: esophago-gastric junction distensibility index, distensibility plateau and diameter values were higher in controls than in patients, although six weeks of treatment seems a short period to observe significant changes in esophageal biomechanics. Repetitive antegrade contractions are the predominant pattern in healthy subjects and eosinophilic esophagitis. We provide normality values for esophageal biomechanics, measured by impedance planimetry in our setting.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Esofagite Eosinofílica/diagnóstico , Doenças do Esôfago/tratamento farmacológico , Complacência (Medida de Distensibilidade) , Transtornos de Deglutição , Junção Esofagogástrica , Fenômenos Biomecânicos , Espanha , Estudos de Casos e Controles , Gastroenteropatias , Doenças do Sistema Digestório
3.
Med. oral patol. oral cir. bucal (Internet) ; 28(6): e553-e561, nov. 2023. tab, ilus
Artigo em Inglês | IBECS | ID: ibc-227374

RESUMO

Background: The aim of this study was to evaluate the stress occurring in the fixation systems both developed in various geometric designs for this study and currently used in sagittal split ramus advancement osteotomy using finite element analysis. Material and Methods: The finite element model that imitates three-dimensional sagittal split advancement osteotomy was fixed in 10 different miniplate fixation methods: one miniplate fixed with four monocortical screws in a horizontal and oblique pattern; four-hole two miniplates with eight monocortical screws; five-hole miniplate fixed with four monocortical and one bicortical screws; six-hole straight and curved miniplates fixed with six monocortical screws in different geometric designs. Unilateral masticatory muscle loads that have previously determined in the literature were applied to the model at the anatomical muscle attachment regions and the data obtained from finite element analysis and static linear analysis methods were recorded as Von mises, maximum principle and minimum principle stress values. Results: It was observed from the results that maximum stress occurred in Group 1, which consisted of double backward T-shaped miniplate with 6-holes and, minimum stress occured in group 10, which mimiced hybrid system with one miniplate and four monocortical and one bicortical screws. Conclusions: Based on our results, the stress on the miniplates changes according to the geometric designs and the stress on the miniplate decreases as the numbers of miniplates and bars increase. The hybrid miniplate may be preferred by the surgeon as it will be exposed to less stress in excessive mandibular advancements by using the advantages of both the miniplate and the bicortical screw. (AU)


Assuntos
Humanos , Placas Ósseas , Osteotomia Sagital do Ramo Mandibular/métodos , Mandíbula/cirurgia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Técnicas de Fixação da Arcada Osseodentária
4.
Rev. Asoc. Esp. Espec. Med. Trab ; 32(3)sep. 2023. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-227708

RESUMO

Introducción: Los Trastornos musculoesqueléticos (TME) son un problema importante en salud, causan incapacidad y disminuyen la rentabilidad de las empresas. Objetivos: Evaluar el riesgo por sobrecarga biomecánica, realizar mediciones antropométricas para un rediseño de puesto de trabajo orientado a la prevención. Material y Métodos: Estudio descriptivo de corte transversal en un puesto de trabajo mediante normas ISO TR 12295, antropometría a 10 trabajadoras con norma ISO 7250-1:2017 y rediseño del puesto bajo norma ISO 14738. Resultados: Se evidenció levantamiento manual de cargas en nivel crítico, postura forzada estática en nivel inaceptable, movimientos repetitivos de extremidad superior derecha ocrachecklist de 11,5. Se obtuvieron las medidas antropométricas de 10 trabajadoras con lo cual se planteó el rediseño del puesto de trabajo. Conclusiones: El rediseño logro eliminar el peligro por levantamiento manual de cargas y reducir el riesgo de posturas forzadas y movimientos repetitivos de extremidad superior. (AU)


Introduction: Musculoskeletal Disorders (MSD) are a major health problem, cause disability and reduce the profitability of companies. Objectives: To evaluate the risk to biomechanical overload, to carry out anthropometric measurements for a prevention-oriented job redesign. Material and Methods: Descriptive cross-sectional study in a job using ISO TR 12295 standards, anthropometry of 10 workers with ISO 7250-1: 2017 standards and redesign of the job under ISO 14738 standards. Results: manual lifting of loads at a critical level, forced static posture at an unacceptable level, repetitive movements of the right upper extremity, or a ocrachecklist of 11.5, were evidenced. The anthropometric measurements of 10 workers were obtained, with which the redesign of the job was proposed. Conclusions: The redesign managed to eliminate the danger of manual lifting of loads and reduce the risk of forced postures and repetitive movements of the upper extremity. (AU)


Assuntos
Humanos , Doenças Musculoesqueléticas , Medicina do Trabalho , Fenômenos Biomecânicos , Estudos Transversais , Epidemiologia Descritiva , Bolívia
5.
Rev. int. androl. (Internet) ; 21(2): 1-9, abr.-jun. 2023. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-218837

RESUMO

Introduction: Human semen analysis must be performed after the liquefaction of the ejaculate. This takes place about 30min after ejaculation and samples must be maintained in the lab during this time. The temperatures for this incubation and the final analysis of motility are crucial but seldom taken into account. This study aims to examine the effect of these temperatures on various sperm parameters both manually (sperm count, motility, morphology, viability, chromatin condensation and maturation and DNA fragmentation) and CASA (kinematics and morphometrics, using an ISAS®v1 CASA-Mot and CASA-Morph systems, respectively) analyzed. Methods: Seminal samples from thirteen donors were incubated for 10min at 37°C followed by additional 20min at either room temperature (RT, 23°C) or 37°C and then examined following WHO 2010 criteria. Results: The data obtained show that there were no significant differences (P>0.05) in the subjective sperm quality parameters with incubation temperature. On the other hand, the head sperm morphometric parameters were significantly higher after room temperature incubation showing, in addition, lower ellipticity (P<0.05). Furthermore, kinematic parameters were evaluated both at RT and 37°C for the two incubation temperatures. In general, the four temperature combinations showed that kinematic parameters followed this order: RT-RT Conclusions: Our results showed that temperature control during both incubation and analysis is needed for accurate semen analysis, recommending the use of 37°C during the entire process. (AU)


Introducción: El análisis de semen humano debe realizarse después de la licuefacción del eyaculado. Esto ocurre aproximadamente a los 30minutos después de la eyaculación. Las temperaturas para esta incubación y el análisis final de la motilidad son cruciales, pero rara vez se tienen en cuenta. Este estudio tiene como objetivo examinar el efecto de estas temperaturas en varios parámetros de los espermatozoides tanto de forma manual (recuento de espermatozoides, motilidad, morfología, viabilidad, condensación y maduración de la cromatina y fragmentación del ADN) como CASA (cinemática y morfometría, utilizando un CASA-Mot ISAS®v1 y Sistemas CASA-Morph, respectivamente) analizados. Métodos: Las muestras seminales de 13 donantes se incubaron durante 10minutos a 37°C, seguidas de 20minutos adicionales a temperatura ambiente (TA, 23°C) o a 37°C y luego se examinaron siguiendo los criterios de la OMS 2010. Resultados: Los datos obtenidos muestran que no hubo diferencias significativas (p>0,05) en los parámetros subjetivos de calidad del esperma con la temperatura de incubación. Por otro lado, los parámetros morfométricos de la cabeza de los espermatozoides fueron significativamente más altos después de la incubación a temperatura ambiente, mostrando, además, una elipticidad más baja (p<0,05). Además, los parámetros cinemáticos se evaluaron tanto a temperatura ambiente como a 37°C para las dos temperaturas de incubación. En general, las cuatro combinaciones de temperatura mostraron que los parámetros cinemáticos siguieron este orden: RT-RT < RT-37 < 37-37 < 37-RT (temperaturas de incubación y análisis, respectivamente). Conclusiones: Nuestros resultados mostraron que el control de la temperatura durante la incubación y el análisis es necesario para un análisis de semen preciso, recomendando el uso de 37°C durante todo el proceso. (AU)


Assuntos
Humanos , Masculino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Sêmen , Motilidade dos Espermatozoides , Espermatozoides , Análise do Sêmen/métodos , Fenômenos Biomecânicos
6.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): 125-133, Mar-Abr. 2023. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-217110

RESUMO

Objetivo: Comprobar si la aplicación de fijación externa mediante barra curva conectada a clavos de Schanz supraacetabulares confiere mayor estabilidad al anillo pélvico con una lesión tipo Tile C1 cuando se realiza el montaje con la barra pretensada que con el montaje estándar (sin pretensar). Material y métodos: Pelvis sintéticas (N=5) con lesión verticalmente inestable estabilizada con ambos montajes, se sometieron a carga axial progresiva. Se midieron las fuerzas aplicadas y las variaciones en las posiciones de marcadores situados en la articulación sacroilíaca y la sínfisis se registraron con un sistema óptico. Se determinaron los desplazamientos relativos entre las superficies lesionadas, la rigidez, la resistencia y el modo de fallo de cada montaje. Resultados: Con el fijador pretensado, la rigidez del montaje en la articulación sacroilíaca resultó muy superior a la del montaje convencional (p=0,043) multiplicándola por 3,45, siendo 2,06 veces mayor en la sínfisis. La resistencia ante el fallo también fue superior, multiplicándola por 2 (p=0,043). Discusión: El aumento de estabilidad a carga axial con el fijador externo pretensado concuerda con su capacidad de producir compresión activa simultánea en los elementos posteriores y anteriores del anillo pélvico, demostrada previamente. Este resultado soporta los excelentes resultados clínicos preliminares obtenidos como tratamiento provisional. Conclusiones: El fijador externo pretensado aumenta la estabilidad axial de los elementos óseos posteriores del anillo pélvico con lesión tipo Tile C1 en modelo sintético, sin disminuir la capacidad de estabilización anterior propia de la fijación externa anterior.(AU)


Objective: The aim of our work is to check if the use of a pre-tensed bar connected to 2supra-acetabular Schanz pins is more stable in a pelvic with a tile C1 injury. Material and methods: We used synthetic pelvis (N=5) with a unstable vertical injury, stabilized with both the standard and the pre-tensed system. They both were submitted to axial loading. We measured applied forces and the position of markers that were positioned in the sacroiliac and symphysis joints. We determined the relative movements between injured surfaces, rigidity, resistance and when each system failed. Results: When using the pre-tensed fixator, the rigidity was much higher in the sacro-iliac joint (P=.043) being 3.45 times higher, being also 2.06 times higher in pubic symphysis (P=.043). The resistance against failure was 2 times higher too (P=.043). Discussion: The increased axial stability with the pre-tensed external fixator accords with its ability to make active compression in both posterior and anterior elements of the pelvic ring, which was previously demonstrated. This result supports the preliminary clinic outcomes that were obtained. Conclusions: The pre-tensed external fixator increases the axial stability of the pelvic ring's posterior elements in a synthethic pelvis with a Tile C1 injury, without decreasing it's capacity to achieve an anterior stability.(AU)


Assuntos
Humanos , Suporte de Carga , Fenômenos Biomecânicos , Pelve/cirurgia , Fixadores Externos , Fraturas Ósseas , Fixação de Fratura , Traumatologia , Ortopedia
7.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): T125-T133, Mar-Abr. 2023. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-217111

RESUMO

Objetivo: Comprobar si la aplicación de fijación externa mediante barra curva conectada a clavos de Schanz supraacetabulares confiere mayor estabilidad al anillo pélvico con una lesión tipo Tile C1 cuando se realiza el montaje con la barra pretensada que con el montaje estándar (sin pretensar). Material y métodos: Pelvis sintéticas (N=5) con lesión verticalmente inestable estabilizada con ambos montajes, se sometieron a carga axial progresiva. Se midieron las fuerzas aplicadas y las variaciones en las posiciones de marcadores situados en la articulación sacroilíaca y la sínfisis se registraron con un sistema óptico. Se determinaron los desplazamientos relativos entre las superficies lesionadas, la rigidez, la resistencia y el modo de fallo de cada montaje. Resultados: Con el fijador pretensado, la rigidez del montaje en la articulación sacroilíaca resultó muy superior a la del montaje convencional (p=0,043) multiplicándola por 3,45, siendo 2,06 veces mayor en la sínfisis. La resistencia ante el fallo también fue superior, multiplicándola por 2 (p=0,043). Discusión: El aumento de estabilidad a carga axial con el fijador externo pretensado concuerda con su capacidad de producir compresión activa simultánea en los elementos posteriores y anteriores del anillo pélvico, demostrada previamente. Este resultado soporta los excelentes resultados clínicos preliminares obtenidos como tratamiento provisional. Conclusiones: El fijador externo pretensado aumenta la estabilidad axial de los elementos óseos posteriores del anillo pélvico con lesión tipo Tile C1 en modelo sintético, sin disminuir la capacidad de estabilización anterior propia de la fijación externa anterior.(AU)


Objective: The aim of our work is to check if the use of a pre-tensed bar connected to 2supra-acetabular Schanz pins is more stable in a pelvic with a tile C1 injury. Material and methods: We used synthetic pelvis (N=5) with a unstable vertical injury, stabilized with both the standard and the pre-tensed system. They both were submitted to axial loading. We measured applied forces and the position of markers that were positioned in the sacroiliac and symphysis joints. We determined the relative movements between injured surfaces, rigidity, resistance and when each system failed. Results: When using the pre-tensed fixator, the rigidity was much higher in the sacro-iliac joint (P=.043) being 3.45 times higher, being also 2.06 times higher in pubic symphysis (P=.043). The resistance against failure was 2 times higher too (P=.043). Discussion: The increased axial stability with the pre-tensed external fixator accords with its ability to make active compression in both posterior and anterior elements of the pelvic ring, which was previously demonstrated. This result supports the preliminary clinic outcomes that were obtained. Conclusions: The pre-tensed external fixator increases the axial stability of the pelvic ring's posterior elements in a synthethic pelvis with a Tile C1 injury, without decreasing it's capacity to achieve an anterior stability.(AU)


Assuntos
Humanos , Suporte de Carga , Fenômenos Biomecânicos , Pelve/cirurgia , Fixadores Externos , Fraturas Ósseas , Fixação de Fratura , Traumatologia , Ortopedia
8.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): 144-152, Mar-Abr. 2023. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-217116

RESUMO

Background: Calcaneal fractures can be high energy intra-articular injuries associated with joint depression. Challenges to fracture reduction include lateral wall blow out, medial wall overlap, comminution and central bone loss. Secondary deformity such as hindfoot varus alters foot biomechanics. Minimally invasive approaches with indirect reduction of the calcaneal tuberosity to maintain the reduction using posterior screws is routinely being used in the treatment of joint depression fractures. Biomechanically, optimum screw numbers and configuration is not known. Biomechanical studies have evaluated and proposed different screw configurations, however, it is not clear which configuration best controls varus deformity. This study aims to determine the optimum screw configuration to control varus deformity in Sanders 2B calcaneal fractures. Methods: Sawbone models were prepared to replicate Sanders type 2-B fracture, with central bone loss and comminution. 0.5cm medial wedge of the calcaneal tuberosity was removed to create varus instability. After stabilising posterior facet with a single 4mm partial threaded screw, and applied an 8 hole contoured plate to stabilise the angle of Gissane, inserted one or two 7mm cannulated partially threaded Charlotte™ (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) Headless Multi-use Compression (under image guidance) extra screws to control varus and subsidence deformity of the fracture. Coronal plane displacement of the dissociated calcaneal tuberosity fragment relative to the body when applying 5N, 10N and 20N force was measured in millimetres (mm). Results: 2 screws inserted (one medial screw into the sustentaculum talus from inferior to superior and, one lateral screw into the long axis anterior process) provides the least displacement (0.88±0.390 at 5N and 1.7±1.251 at 20N) and the most stable construct (p<0.05) when compared to other configurations...(AU)


Introducción: Las fracturas de calcáneo suelen ser lesiones intraarticulares de alta energía asociadas con hundimiento articular. Además, se añade con frecuencia el estallido de la pared lateral, la superposición de la pared medial, la conminución y la pérdida de hueso bajo la carilla articular. La deformidad secundaria, como el varo del retropié, altera la biomecánica del pie. Nuestra comunidad utiliza cada vez más abordajes mínimamente invasivos con reducción indirecta de la tuberosidad del calcáneo para mantener la reducción mediante tornillos posteriores. Hay estudios que proponen diferentes configuraciones de tornillos, tras experimentación biomecánica, pero aún no es bien conocido qué configuración controla mejor la deformidad en varo. Este estudio tiene como objetivo determinar la configuración óptima del tornillo para controlar la deformidad en varo en las fracturas de calcáneo Sanders 2B. Método: Se prepararon modelos en Sawbone para replicar la fractura de Sanders tipo 2B, con pérdida de hueso central y con conminución. Se eliminó una cuña medial de 0,5cm de la tuberosidad calcánea para crear inestabilidad en varo. Tras estabilizar el ángulo de Gissane con un tornillo aislado parcialmente roscado de 4mm y una placa moldeada, se utilizaron tornillos de compresión multiuso Charlotte (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) sin cabeza, canulados y parcialmente roscados de 7mm insertados sobre una AK bajo escopia. El desplazamiento del plano sagital del fragmento de tuberosidad fracturado en comparación con el cuerpo al aplicar una fuerza de 5N, 10N y 20N se midió en milímetros (mm). Resultados: Dos tornillos insertados (un tornillo medial en el sustenaculum tali de inferior a superior y un tornillo lateral en el eje largo del astrágalo) proporciona el menor desplazamiento (0,88±0,390 a 5N y 1,7±1,251 a 20N) y resulta la construcción más estable (p<0,05) en comparación con otras configuraciones...(AU)


Assuntos
Humanos , Parafusos Ósseos , Calcâneo/lesões , Calcanhar/cirurgia , Fenômenos Biomecânicos , Ortopedia
9.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): T144-T15, Mar-Abr. 2023. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-217117

RESUMO

Background: Calcaneal fractures can be high energy intra-articular injuries associated with joint depression. Challenges to fracture reduction include lateral wall blow out, medial wall overlap, comminution and central bone loss. Secondary deformity such as hindfoot varus alters foot biomechanics. Minimally invasive approaches with indirect reduction of the calcaneal tuberosity to maintain the reduction using posterior screws is routinely being used in the treatment of joint depression fractures. Biomechanically, optimum screw numbers and configuration is not known. Biomechanical studies have evaluated and proposed different screw configurations, however, it is not clear which configuration best controls varus deformity. This study aims to determine the optimum screw configuration to control varus deformity in Sanders 2B calcaneal fractures. Methods: Sawbone models were prepared to replicate Sanders type 2-B fracture, with central bone loss and comminution. 0.5cm medial wedge of the calcaneal tuberosity was removed to create varus instability. After stabilising posterior facet with a single 4mm partial threaded screw, and applied an 8 hole contoured plate to stabilise the angle of Gissane, inserted one or two 7mm cannulated partially threaded Charlotte™ (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) Headless Multi-use Compression (under image guidance) extra screws to control varus and subsidence deformity of the fracture. Coronal plane displacement of the dissociated calcaneal tuberosity fragment relative to the body when applying 5N, 10N and 20N force was measured in millimetres (mm). Results: 2 screws inserted (one medial screw into the sustentaculum talus from inferior to superior and, one lateral screw into the long axis anterior process) provides the least displacement (0.88±0.390 at 5N and 1.7±1.251 at 20N) and the most stable construct (p<0.05) when compared to other configurations...(AU)


Introducción: Las fracturas de calcáneo suelen ser lesiones intraarticulares de alta energía asociadas con hundimiento articular. Además, se añade con frecuencia el estallido de la pared lateral, la superposición de la pared medial, la conminución y la pérdida de hueso bajo la carilla articular. La deformidad secundaria, como el varo del retropié, altera la biomecánica del pie. Nuestra comunidad utiliza cada vez más abordajes mínimamente invasivos con reducción indirecta de la tuberosidad del calcáneo para mantener la reducción mediante tornillos posteriores. Hay estudios que proponen diferentes configuraciones de tornillos, tras experimentación biomecánica, pero aún no es bien conocido qué configuración controla mejor la deformidad en varo. Este estudio tiene como objetivo determinar la configuración óptima del tornillo para controlar la deformidad en varo en las fracturas de calcáneo Sanders 2B. Método: Se prepararon modelos en Sawbone para replicar la fractura de Sanders tipo 2B, con pérdida de hueso central y con conminución. Se eliminó una cuña medial de 0,5cm de la tuberosidad calcánea para crear inestabilidad en varo. Tras estabilizar el ángulo de Gissane con un tornillo aislado parcialmente roscado de 4mm y una placa moldeada, se utilizaron tornillos de compresión multiuso Charlotte (Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN) sin cabeza, canulados y parcialmente roscados de 7mm insertados sobre una AK bajo escopia. El desplazamiento del plano sagital del fragmento de tuberosidad fracturado en comparación con el cuerpo al aplicar una fuerza de 5N, 10N y 20N se midió en milímetros (mm). Resultados: Dos tornillos insertados (un tornillo medial en el sustenaculum tali de inferior a superior y un tornillo lateral en el eje largo del astrágalo) proporciona el menor desplazamiento (0,88±0,390 a 5N y 1,7±1,251 a 20N) y resulta la construcción más estable (p<0,05) en comparación con otras configuraciones...(AU)


Assuntos
Humanos , Parafusos Ósseos , Calcâneo/lesões , Calcanhar/cirurgia , Fenômenos Biomecânicos , Ortopedia
10.
Rev. int. med. cienc. act. fis. deporte ; 23(89): 1-15, mar. 2023. tab, graf, ilus
Artigo em Inglês | IBECS | ID: ibc-219867

RESUMO

The purpose of this study was to determine the foot strike pattern (FSP), inversion (INV) and spatial-temporal variables in a large sample of recreational runners during a long-distance competition, according to sex and changes in the classification race. A total of 368 men and 67 women, who participated in the XVII International Half Marathon of Cordoba (Spain) were analysed. It was recorded at km 5 and km 15, where high-speed camcorder and 2D-photogrammetric techniques were used to measure FSP, INV, contact time (CT) and flight time (FT). The group that worsened their classification at km 15 increase RFS prevalence and INV asymmetry. A Pearson analysis indicates that variation of the classification in the race between the marks km 5 and km 15 is related with CT (r=0.429, p<0.001) and FT (r=-0.360, p<0.001). RFS prevalence and spatial-temporal parameters showed different patterns depending on whether the runners improved or worsened their ranking. (AU)


El objetivo de este estudio fue determinar el patrón de pisada, inversión y variables espaciotemporales para una amplia muestra de corredores amateurs, durante una carrera de larga distancia, según sexo y posición de clasificación. Se analizaron 368 hombres y 67 mujeres, que participaron en la XVII Media Maratón Internacional de Córdoba (España). Se registró el km 5 y km 15, utilizando técnicas de fotogrametría 2D de alta velocidad para medir la pisada, la inversión, el tiempo de contacto (TC) y el tiempo de vuelo (TV). El grupo que empeoró su clasificación en el km 15 aumentó la prevalencia de FSP y la asimetría del INV. Un análisis de Pearson indica que la variación de la clasificación en la carrera está relacionada con TC (r=0,429, p<0,001) y TV (r=-0,360, p<0,001). La prevalencia de retropié y los parámetros espaciotemporales mostraron diferentes patrones dependiendo de si los corredores mejoraron o empeoraron su clasificación. (AU)


Assuntos
Humanos , Corrida , Resistência Física , Fadiga , Espanha , Fenômenos Biomecânicos , Desempenho Físico Funcional
11.
Rev. esp. podol ; 34(2): 62-68, 2023. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-229372

RESUMO

Introducción: La fascitis plantar es uno de los principales motivos de las consultas podológicas. Hay multitud de tratamientos para esta patología, entre los que destacamos tratamiento ortopodológico, físico y farmacológico. Recientemente ha salido al mercado un modelo de calcetín biomecánico que podría tener un efecto positivo frente al tratamiento de la fascitis plantar, pero aún no se han obtenido resultados. Por lo tanto, el objetivo de este trabajo fue comprobar la eficacia en la reducción del dolor y aumento de la función que presenta el calcetín biomecánico en personas que padecen fascitis plantar o dolor en el talón. Pacientes y métodos: La muestra se compuso de 15 participantes, comprendidos en un rango de edad entre 20 y 71 años. Se realizaron dos grupos al azar: uno de 8 participantes (grupo experimental, calcetín Podoks®) y otro de 7 participantes (grupo control). Se realizó a todos los participantes el cuestionario Foot Function Index previo, y después de los 15 días de la utilización del calcetín se le volvió a realizar, anotando el Foot Function Index posterior. Resultados: Tras la evaluación de los resultados obtenidos, se encontraron diferencias en el Foot Function Index previo, presentando las mujeres un estado clínico peor que los hombres. Una vez realizado el periodo de 15 días de seguimiento, se encontró una mejor puntuación en la subescala de dolor del Foot Function Index, presentando el grupo Podoks® una media de 28.6 ± 18.0 y el grupo control 39.4 ± 21.6 (p = 0.043). Conclusiones: Los calcetines biomecánicos pueden ser una buena alternativa para el tratamiento de la fascitis plantar, como apoyo a otros tratamientos, ya que mejoran el dolor percibido a los 15 días. Esto podría ser debido a la instauración temprana del mecanismo de Windlass, lo que provoca que el arco interno del pie sea más estable y reduciendo así un excesivo estrés tensil sobre la fascia plantar, ligamentos plantares, músculos intrínsecos y musculatura flexora plantar (AU)


Introduction: Plantar fasciitis is one of the main reasons in podiatric consultations. There are many treatments for this pathology, among which we highlight, orthopedic, physical and pharmacological treatments. In the market, biomechanical sock models has been discovered that could have a positive effect against the treatment of plantar fasciitis, but no results have yet been obtained. Therefore, the objective of this work was to verify the efficacy of the biomechanical sock in reducing pain or improving foot function people suffering from plantar fasciitis or heel pain. Patients and methods: The sample consisted of 15 participants, included in an age range between 20 and 71 years. Two random groups were held, one of 8 participants (experimental group, Podoks® socks) and another of 7 participants (control group). The previous Foot Function Index questionnaire was carried out on all participants, and after 15 days of wearing the sock, it was carried out again, noting the subsequent Foot Function Index. Results: After evaluating the results obtained, differences were found in the previous Foot Function Index, with women presenting a worse clinical state than men. After the 15-day follow-up period, a better score was found in the pain subscale of the Foot Function Index, with the Podoks® group presenting a mean of 28.6 ± 18.0 and the control group 39.4 ± 21.6 (p = 0.043) Conclusions: Biomechanical socks can be a good alternative for the treatment of plantar fasciitis, as a support to other treatments, since they improve the perceived pain after 15 days. This could be related to the early establishment of the Windlass mechanism, which causes the internal arch of the foot to be more stable, thereby reducing excessive tensile stress on the plantar fascia, plantar ligaments, intrinsic muscles, and plantar flexor musculature (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Fasciíte Plantar/terapia , Fenômenos Biomecânicos , Resultado do Tratamento , Seguimentos
12.
Rev. esp. podol ; 34(2): 121-131, 2023. ilus
Artigo em Espanhol | IBECS | ID: ibc-229381

RESUMO

Este artículo examina la relación entre los patrones de pisada de corredores de larga distancia (Rearfoot Strike [RFS] y Non Rearfoot Strike [NRFS]) y varios aspectos como lesiones, rendimiento y biomecánica. A pesar de que correr se ha establecido como una actividad popular con beneficios cardiovasculares, respiratorios y psicológicos, conlleva un riesgo significativo de lesiones. Se encontró que la mayoría de los corredores adoptan un patrón RFS, que tiende a aumentar con la distancia recorrida, la fatiga y el uso de calzado amortiguado. Aunque algunos estudios sugieren una relación entre ciertos patrones de pisada y lesiones específicas, no hay suficiente evidencia para recomendar cambios en el patrón de pisada para la prevención de lesiones. Los corredores de élite tienden a usar un patrón NRFS más que los amateurs, pero la relación entre el patrón de pisada, el rendimiento y las variables biomecánicas es compleja y varía según el individuo. Se concluye que los profesionales de la salud y entrenadores deben considerar estas variaciones al asesorar a los corredores sobre técnicas y estrategias de entrenamiento, prevención, tratamiento y readaptación de lesiones (AU)


This paper examines the relationship between long-distance runners’ foot strike patterns (Rearfoot Strike [RFS] and Non Rearfoot Strike [NRFS]) and various aspects such as injuries, performance, and biomechanics. While running has established itself as a popular activity with cardiovascular, respiratory, and psychological benefits, it carries a significant risk of injuries. It was found that most runners adopt an RFS pattern, which tends to increase with distance covered and the use of cushioned footwear. Although some studies suggest a relationship between certain foot strike patterns and specific injuries, there is insufficient evidence to recommend changes in foot strike patterns for injury prevention. Elite runners tend to use an NRFS pattern more than amateurs, but the relationship between foot strike patterns, performance, and biomechanical variables is complex and varies indivually. It concludes that health professionals and coaches should consider these variations when advising runners on training techniques and strategies, prevention, treatment, and rehabilitation of injuries (AU)


Assuntos
Humanos , Traumatismos em Atletas/etiologia , Fenômenos Biomecânicos , Corrida/lesões
13.
Rev. int. med. cienc. act. fis. deporte ; 22(88): 863-875, dic. 2022. tab
Artigo em Espanhol | IBECS | ID: ibc-213729

RESUMO

El objetivo de este trabajo es evaluar en 36 corredores aficionados, la fuerza y las presiones del pie sobre tres superficies comúnmente empleadas para el entrenamiento de la carrera en el sitio (césped artificial, suelo técnico de caucho y trampolín plano). Los valores de fuerza y presión se registraron mediante plantillas instrumentadas (Gebiomized® Munster, Germany). Se obtuvieron los siguientes parámetros: Fuerza máxima (N) y picos de presión (N/cm2) en 6 zonas específicas del pie. Según los resultados, la fuerza máxima ejercida por el pie dominante en césped artificial (657 N) y en suelo técnico de caucho (692,5 N) fue significativamente superior al registrado sobre el trampolín (262 N). Respecto a la presión, la mayor parte de la presión ejercida por el pie en superficies duras (césped artificial y suelo técnico de caucho), se observó en las cabezas de los metatarsianos, mientras que en el trampolín la presión se repartió entre estas y el calcáneo. (AU)


The objective of this study is to evaluate the Maximum Force and Peak Pressure of the foot on three surfaces commonly used for running in place training (artificial turf, rubber floor and flat trampoline). Force and pressure were recorded in 36 amateur runners using instrumented insoles (Gebiomized® Munster, Germany). The following parameters were obtained: Maximum Force (N) and Peak Pressure (N/cm2) in 6 specific areas of the foot. According to the results, the maximum force exerted by the dominant foot on artificial turf (657 N) and rubber floor (692.5 N) was significantly higher than the recorded on the trampoline (262 N). Regarding the pressure, most of the pressure exerted by the foot on hard surfaces (artificial turf and technical floor), was observed in the heads of the metatarsals, while in the trampoline the pressure was distributed in the heads of the metatarsals and the calcaneus. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Corrida , , Força Compressiva , Fenômenos Biomecânicos , Entrevistas como Assunto
14.
Asclepio ; 74(2)dic. 2022. ilus
Artigo em Inglês | IBECS | ID: ibc-212892

RESUMO

Many Biomechanics texts and courses begin with a historical introduction. This usually describes the contributions of a large number of people who, over many centuries, have been fundamental to the development of this science. In these presentations it is often stated that the term Biomechanik (Biomechanics) appears to have been used for the first time in 1887 by Dr. Moriz Benedikt, in Über Mathematische Morphologie und Biomechanik. However, this term was previously used by the physiologist William Preyer in 1873 and 1883. In this short article, we show these first mentions and frame them in the context of other terms, Biostatik (Biostatics) and Biodynamik (Biodynamics), used at that time. Finally, as a secondary result of the research, we found what could be the first textbook that specifically addresses Biomechanics as a new object of scientific knowledge.(AU)


Muchos textos y cursos de Biomecánica comienzan con una introducción histórica. Esta suele describir las aportaciones de un gran número de personas que, a lo largo de muchos siglos, han sido fundamentales para el desarrollo de esta ciencia. En estas presentaciones se afirma a menudo que el término Biomechanik (Biomecánica) parece haber sido utilizado por primera vez en 1887 por el Dr. Moriz Benedikt, en Über Mathematische Morphologie und Biomechanik. Sin embargo, este término fue utilizado previamente por el fisiólogo William Preyer en 1873 y 1883. En este breve artículo, mostramos estas primeras menciones y las enmarcamos en el contexto de otros términos, Biostatik (Biostática) y Biodynamik (Biodinámica), utilizados en ese momento. Finalmente, como resultado secundario de la investigación, encontramos el que podría ser el primer libro de texto que aborde específicamente la Biomecánica como un nuevo objeto de conocimiento científico.(AU)


Assuntos
Humanos , Fenômenos Biomecânicos , Fisiologia , História da Medicina , Ciência/história , Vitalismo
15.
Rev. int. med. cienc. act. fis. deporte ; 22(87): 565-578, sept. 2022. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-211089

RESUMO

Los objetivos del presente estudio son evaluar la fiabililidad test-retest e inter-observador del software Kinovea® para la obtención de los principales parámetros espaciotemporales de la marcha, así como, estudiar la validez de criterio respecto a un sistema tridimensional de análisis del movimiento. Los resultados obtenidos son significativamente estadísticos (p < 0,05) en todos los parámetros estudiados. La fiabilidad test-retest muestra una correlación excelente en los parámetros de longitud de paso, longitud de zancada, tiempo de paso y tiempo de zancada (CCI > 0,90), y buena en la velocidad (CCI = 0,76-0,90). La fiabilidad inter-observador es excelente (CCI > 0,90) en todos los parámetros espaciotemporales estudiados en ambos observadores. La validez de criterio entre Kinovea® y VICON Motion System® es excelente para los parámetros estudiados (r > 0,80) en ambos evaluadores. Estos hallazgos respaldan el empleo de Kinovea® como una herramienta accesible y de fácil manejo, con la que obtener datos objetivos de la marcha. (AU)


The aims of this study are to evaluate test-retest ant inter-rater reliability of the software Kinovea® to obtain the spatiotemporal gait parameters, as well as to study the criterion validity with respect to a three-dimensional motion capture system. The results obtained are statically significant (p < 0.05) in all the parameters studied. The test-retest reliability shows an excellent correlation in the parameters of step length, stride length, step time and stride time (ICC > 0.90), and good in speed (ICC = 0.76-0.90). The inter-rater evaluation is excellent (ICC > 0.90) in all the spatiotemporal parameters studied in both raters. The criterion validity between Kinovea® and VICON Motion System® is excellent for the parameters studied (r > 0.80) in both raters. These findings support the use of Kinovea® as an accessible and easy-to-use tool with which to obtain objective gait data. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Análise da Marcha , Reprodutibilidade dos Testes , Software , Teste de Caminhada , Fenômenos Biomecânicos
16.
Rev. int. med. cienc. act. fis. deporte ; 22(87): 615-633, sept. 2022. tab
Artigo em Espanhol | IBECS | ID: ibc-211092

RESUMO

El objetivo del presente trabajo consistió en analizar las relaciones existentes entre los parámetros de carga interna (objetiva y subjetiva) y externa. La muestra estuvo compuesta por un total de 15 partidos disputados en el Eurobasket femenino U-16, donde participaron un total de nueve árbitros (6 masculinos y 3 femeninos). Las variables analizadas de carga interna fueron la frecuencia cardiaca y la percepción subjetiva de esfuerzo. Las variables de carga externa se dividieron en cinemáticas y neuromusculares, medidas a través de dispositivos inerciales. Los resultados explican que existen relaciones entre los valores de carga interna objetiva y carga externa, así como entre las variables de carga externa. En cambio, no existen relaciones entre la carga interna subjetiva y las variables de carga interna y externa objetiva, exceptuando el PowerMetabolic. Estos resultados demuestran que la competición y el nivel de los árbitros influyen en gran medida en las variables subjetivas. (AU)


The aim of the present paper consists in analysing the relations between internal (objective and subjective) and external load parameters. The sample was composed of a total of 15 matches played in the women’s U16 Eurobasket championship, in which a total of nine referees (6 men and 3 women) participated. The internal load variables analysed were heart rate and the subjective rating of perceived exertion. The external load variables were divided into kinematic and neuromuscular variables, measured using inertial devices. The results show that there are associations between the values of objective internal load and external load, as well as between the variables of external load. In contrast, there is no relation between internal subjective load and the variables of objective internal and external load, except regarding Metabolic Power. These results indicate that the competition and the level of the referees greatly influence the subjective variables. (AU)


Assuntos
Humanos , Masculino , Feminino , Basquetebol , Frequência Cardíaca , Esforço Físico , Fenômenos Biomecânicos , Estudos Transversais , Europa (Continente)
17.
Rehabilitación (Madr., Ed. impr.) ; 56(3): 195-203, Jul - Sep 2022. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-204910

RESUMO

El patrón de marcha en la niñez está constantemente cambiando producto de la maduración neuroanatómica propia del crecimiento, y por esto nos proponemos identificar, a partir de los estudios publicados, los rasgos esenciales para la obtención del patrón biomecánico de la marcha en niños sanos. Se realizó una búsqueda de artículos científicos en Scopus, SciELO, PubMed y PEDro donde se evalúa la marcha en sujetos menores de 18 años, partiendo de los métodos de captura de movimiento y los parámetros biomecánicos. Los resultados arrojaron que de 7 a 9 años el niño adquiere el patrón de marcha definitivo; la captura de movimiento más utilizada es el método óptico Vicon con video, plataforma de fuerza y electromiografía, y los parámetros evaluados fueron espaciales, temporales, espaciotemporales, cinemáticos, cinéticos y electromiográficos.(AU)


The gait patter in childhood is constantly changing as a result of the neuro-anatomical maturation due to growth, for this reason we propose to identify from published studies and the motion capture method, the essential features for obtaining the biomechanical pattern of gait in children. A search for scientific articles was carried out in Scopus, SciELO, PudMed and PEDro where gait is evaluated in subjects under 18 years old, based on motion capture methods and biomechanical parameters. The results showed that from 7 to 9 years old the child acquires the definitive gait pattern, the most used motion capture method was Vicon, with the use of video, force platform and electromyography and the parameters used were the spatial, temporal, spatial–temporal, kinematic, kinetic and electromyographic.(AU)


Assuntos
Humanos , Criança , Velocidade de Caminhada , Análise da Marcha , Fenômenos Biomecânicos , Cinética , Eletromiografia , Sistema Musculoesquelético , Medicina Física e Reabilitação
18.
Rehabilitación (Madr., Ed. impr.) ; 56(3): 237-242, Jul - Sep 2022. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-204914

RESUMO

En personas con amputación transtibial unilateral (ATU) usualmente se presentan deficiencias en los mecanismos que fundamentan la marcha, posiblemente debido a la ausencia del segmento reseccionado, lo cual impacta la capacidad para ajustar activamente el miembro inferior protetizado. Se incluyeron cinco participantes con ATU, evaluando las fuerzas de reacción desde el piso durante la marcha mediante un sistema integrado BTS GAITLAB. En el miembro inferior sano (MIS) la primera fuerza de pico vertical y la segunda tendieron a ser mayores que en el miembro inferior protetizado (MIP). Tanto las fuerzas de desaceleración como de propulsión fueron menores en esta extremidad, además, se observó variabilidad en las fuerzas mediolaterales. La dependencia para mantener control activo del centro de gravedad durante la marcha desde el MIS se dio probablemente por restricciones mecánicas en el control activo del tobillo y limitaciones para absorber y generar fuerzas que permitan controlar la estabilidad postural durante la marcha desde el MIP.(AU)


Unilateral Transtibial Amputees (UTA) usually present deficiencies in the mechanisms underlying their gait likely because of the absence of the resected segment, thus having an impact on the ability to actively adjust the lower limb prosthesis. Five participants with UTA were evaluated considering the ground reaction forces during gait by using an integrated BTS GAITLAB system. The first and the second vertical peak forces tended to be greater in the Healthy Lower Limb (HLL) than in the Lower Limb prosthesis (LLP). Both the deceleration and propulsion forces were lower in this limb prosthesis, in addition, a variability of the mediolateral force was observed. Maintaining active control of the center of gravity during gait from the HLL was probably due to mechanical restrictions to actively control the ankle and the limitations for force absorption and generation that allow controlling postural stability during gait from the LLP.(AU)


Assuntos
Humanos , Masculino , Adulto , Velocidade de Caminhada , Amputação Cirúrgica , Amputados , Extremidade Inferior , Fenômenos Biomecânicos , Especialidade de Fisioterapia , Retroalimentação Sensorial , Medicina Física e Reabilitação
19.
Rev. andal. med. deporte ; 15(2): 43-47, Jun. 2022. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-209901

RESUMO

Objective: To verify if three-weeks of training cessation affects 200 m front crawl performance and kinematics in 12 years old and under age-groupswimmers controlling for anthropometric changes.Method:Sixteen age-group swimmers: 11 girls (age 10.0 ± 1.3 y) and 5 boys (age 10.5 ± 1.0 y) performed a 200 m front crawl test (T200) (time trial)PRE- and POST three-weeks (off-season), where performance, kinematics and anthropometrics variables were obtained. Results: Height and arm span increased (height ~1.0 cm - CI: 0.70 to 1.3 cm; p < 0.001; d= 1.22; arm span ~1.0 cm - CI: 0.20 to 1.4 cm; p = 0.007; d =0.68). Trivial changes were observed for performance (mean diff: 3.3 s CI: -6.7 to 13.9; p = 0.69; d = 0.08) and kinematical variables (p from 0.69 to 0.84;d = 0.04 to 0.17). High intraclass correlations (ICC: 0.69 to 0.84; p < 0.001) were observed for all variables after three-weeks, indicating stability overtime.Conclusion: Three-weeks off-season does not impair swimming T200 performance and kinematic variables in 12 years old and under age-groupswimmers.(AU)


Objetivo: Verificar si tres semanas de interrupción del entrenamiento afectan el rendimiento y la cinemática de 200 m en nado crol en nadadores de 12años y menores mientras se controlan los cambios antropométricos.Método: Dieciséis nadadores de grupos de edad: 11 niñas (edad 10.0 ± 1.3 años) y 5 niños (edad 10.5 ± 1.0 años)realizaron una prueba de 200 m nadocrol (contrarreloj) pre y post tres semanas (fuera de temporada), donde se obtuvieron el rendimiento, variables cinemáticas y antropométricas.Resultados: La altura y la envergadura han aumentado (altura ~ 1.0 cm; IC: 0.70 a 1.3 cm; p <0.001; d = 1.22; envergadura ~ 1.0 cm; IC: 0.2 a 1.4 cm; p<0.001; d = 0.68). Se observaron cambios triviales para el rendimiento (diferencia media: 3.3 s IC: -6.7 a 13.9; p = 0.69; d = 0.08) y las variablescinemáticas (p de 0.69 a 0.84; d = 0.04 a 0.17). Se observaron altas correlaciones intraclase (CCI: 0.69 a 0.84; p <0.001) para todas las variables despuésde tres semanas, lo que indica estabilidad en el tiempo.Conclusión: Tres semanas fuera de temporada no afecta el rendimiento en 200 m nado crol ni las variables cinemáticas en nadadores de 12 años ymenores(AU)


Objetivo: Verificar se três semanas de interrupção do treinamento afetam o desempenho e a cinemática em 200 m nado crawl de nadadores de até 12anos de idade, controlando as alterações antropométricas.Método: Dezesseis nadadores de grupos de idade: 11 meninas (idade 10.0 ± 1.3 anos) e 5 meninos (idade 10.5 ± 1.0 anos) realizaram um teste de 200 mem nado crawl (contrarrelógio) pré e pós três semanas (fora de temporada), quando o desempenho, variáveis cinemáticas e antropométricas foramobtidas.Resultados: Estatura e envergadura aumentaram (estatura ~ 1.0 cm - IC: 0.70 a 1.3 cm; p <0.001; d = 1.22; envergadura ~1.0 cm - CI: 0.20 a 1.4 cm; p =0.007; d = 0.68). Mudanças triviais foram observadas para desempenho (diferença média: 3,3 s IC: -6,7 a 13,9; p = 0,69; d = 0,08) e variáveis cinemáticas(p de 0.69 a 0.84; d = 0.04 a 0.17). Correlações intraclasse foram elevadas (ICC: 0.69 a 0.84; p <0.001) e observadas para todas as variáveis após trêssemanas, indicando estabilidade ao longo do tempo.Conclusão: Três semanas fora da temporada não prejudicam o desempenho de natação em 200 m nado crawl e as variáveis cinemáticas em nadadores de12 anos e mais novos.(AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Desempenho Atlético , Desempenho Físico Funcional , 51654 , Teste de Esforço , Natação , Exercício Físico , Fenômenos Biomecânicos , Antropometria , Medicina Esportiva , Espanha , Estudos de Coortes , Estudos Longitudinais
20.
Cir. plást. ibero-latinoam ; 48(2): 217-226, abr. - jun. 2022. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-208945

RESUMO

Introducción y objetivo: El amplio rango de movimiento y fuerza de la mano ha sido clave en el desarrollo de la especie humana dada su capacidad de adaptación según las demandas funcionales. El conocimiento de la anatomía y biomecánica de las estructuras que influyen en la generación de la fuerza de los dedos es crucial para el entendimiento de las alteraciones que pueden producir un deterioro de la misma. Son múltiples los estudios para valorar la fuerza de cada dedo y su rol en la funcionalidad del complejo sistema músculo-esquelético de la mano. En este trabajo descriptivo revisamos conceptos básicos y presentamos las etapas de diseño y construcción de un dispositivo tridimensional capaz de cuantificar de manera individual la fuerza de los dedos para la evaluación en pacientes sanos. Material y método: Realzamos múltiples mediciones en 20 pacientes sanos con un dispositivo que discrimina la fuerza de cada dedo y comparamos los resultados con estudios previamente publicados. Resultados: Los hallazgos numéricos de las diferentes mediciones son equiparables entre si y con los resultados en estudios previos. Conclusiones: Este nuevo dispositivo brinda la posibilidad de medir la fuerza de los dedos de manera individual, como valiosa herramienta en la evaluación del paciente sano y de pacientes con patologías traumáticas y no traumáticas, para cuantificar su grado de discapacidad, evolución postoperatoria o de su enfermedad de manera especifica al dedo comprometido y el impacto en la fuerza global de agarre. (AU)


Background and objective: The wide range of movement and strength of the hand have been key in the development of the human species given its ability to adapt according to functional demands. Knowledge of the anatomy and biomechanics of the structures that influence the generation of fingers force is crucial to understand the alterations that can cause its deterioration. Multiple studies have been conducted to assess the strength of each finger and its role in the functionality of the complex musculoskeletal system of the hand. In this descriptive paper, basic concepts are reviewed and stages of design and construction of a three-dimensional device capable of individually quantify the strength of each finger for healthy patients evaluation is presented. Methods: Multiple measurements were performed in 20 healthy patients with a device that discriminates the strength of each finger, comparing the results with previously published studies. Results: The results of the different measures are comparable with each other and with the results in previous studies. Conclusions:The use of this new device offers the possibility of measuring the strength of the fingers individually, which constitutes a valuable and novel tool in the evaluation of healthy patients and patients with traumatic and non-traumatic pathologies, to quantify their degree of disability, postoperative evolution or its disease specifically to the involved finger and its impact on the global grip strength. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Força da Mão , Dedos , Fenômenos Biomecânicos , Desenho Assistido por Computador , Equipamentos e Provisões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...