Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Bol. malariol. salud ambient ; 62(3): 526-545, 2022. tab, graf
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1397154

RESUMO

El acceso al agua potable por red pública es un problema de la población rural en el departamento de Huánuco, por ende, se suele realizar el consumo de este recurso sin previo tratamiento, produciéndose así enfermedades estomacales. El uso de agentes naturales como el Aloe vera (L.) (Sábila) viene a ser una alternativa como floculante para el tratamiento convencional del agua, por tal motivo, en esta investigación se visualizaron experimentalmente las características y reacciones del gel de A. vera como floculante en la remoción de la turbidez. La turbidez del agua se simuló con el caolín, y se determinó la concentración óptima de alúmina y sábila (1%) a valores diferentes de pH y turbidez iniciales, con los datos resultantes se optimizó las dosis mediante el modelo matemático de superficie de respuesta, para después realizar su respectiva validación mediante métodos gráficos e índices matemáticos; los resultados reflejaron que la turbidez inicial, pH inicial y la dosis del coagulante influyen significativamente en la remoción de la turbidez de agua, de forma individual, concluyendo según el modelo de superficie de respuesta que el volumen óptimo de sábila al 1% alcanza su mayor eficiencia a 0,1 mL y 0,4 mL por cada 500 mL, dosis que varía de acuerdo a su pH y turbidez inicial, este modelo matemático se ajusta para aguas superficiales de la ciudad de Tingo María(AU)


Access to drinking water through the public network is a problem for the rural population in the department of Huánuco, therefore, this resource is usually consumed without prior treatment, thus producing stomach illnesses. The use of natural agents such as Aloe vera (L.) becomes an alternative as a flocculant for conventional water treatment, for this reason, in this investigation the characteristics and reactions of the A. vera gel were visualized experimentally as a flocculant in the removal of turbidity. The turbidity of the water was simulated with kaolin, and the optimum concentration of alumina and aloe vera (1%) was determined at different values of initial pH and turbidity. With the resulting data, the doses were optimized using the mathematical model of the response surface. to later carry out their respective validation through graphic methods and mathematical indices; The results showed that the initial turbidity, initial pH and the dose of the coagulant significantly influence the removal of the turbidity of the water, individually, concluding according to the response surface model that the optimal volume of aloe at 1% reaches its highest level. efficiency at 0.1 mL and 0.4 mL per 500 mL, a dose that varies according to its pH and initial turbidity, this mathematical model is adjusted for surface waters of the city of Tingo María(AU)


Assuntos
Abastecimento de Água , Aloe , Óxido de Alumínio , Caulim , Gastropatias , Purificação da Água
2.
Braz. dent. sci ; 25(4): 1-10, 2022. tab, ilus, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1395952

RESUMO

Objective: Endodontic perforation is a challenging mishap that should be repaired with a biocompatible material, Mineral trioxide aggregate (MTA) and Biodentine are the most commonly used repair materials. However, these materials are expensive, (MTA) has prolonged setting time and difficult manipulation. The purpose of this study is to prepare the experimental nano calcium-aluminate/tri-calcium-silicate (CA/C3S) material and comparing its physical properties with biodentine and MTA, to evaluate the experimental material eligibility to compete the commercial repair materials. And to perform part two (animal study) that will evaluate the cytotoxicity, the biocompatibility and the efficacy of (CA/C3S) in furcal perforation repair compared to diode laser. Material and Methods: A mixture of calcium carbonate and aluminum oxide was used to formulate calcium aluminate phase (CA), tri-calcium-Silicate phase (C3S) was formulated by firing of calcium carbonate and quartz. The produced powders were investigated by X-ray diffraction, then (CA) and (C3S) mixed with water.(CA/ C3S) compared with MTA and biodentine for setting-time, micro-hardness, dimensional-stability and solubility. Results: Mean setting time of (CA/C3S) was (32.70±0.75min) which is significantly higher than MTA and Biodentine. The Mean microhardness of (CA/C3S) was (56.50±7.41VHN) which has no statical difference with MTA and Biodentine. Solubility results showed weight increase for (CA/C3S) as following (6.29±3.05)and loss of weight for MTA and Biodentine. The percentage of change in dimensions for(CA/C3S) increased as following (0.64±0.78) while decreased for MTA and Biodentine. Conclusion: The experimental (CA/C3S) material showed good microhardness, dimensional stability and acceptable setting time that could be improved in further work (AU)


Objetivo: A perfuração endodôntica é um percalço desafiador que deve ser reparado com um material biocompatível, Agregado de trióxido mineral (MTA) e Biodentina são os materiais de reparo mais comumente usados. No entanto, esses materiais são caros, (MTA) tem tempo de presa prolongado e difícil manipulação. O objetivo deste estudo é preparar o material experimental de nano aluminato de cálcio/silicato tricálcico (CA/C3S) e comparar suas propriedades físicas com biodentina e MTA, para avaliar a elegibilidade do material experimental para competir com os materiais de reparo comerciais. E realizar a segunda parte (estudo animal) que avaliará a citotoxicidade, a biocompatibilidade e a eficácia do (CA/C3S) no reparo de perfuração de furca em comparação ao laser de diodo.Material e Métodos: Uma mistura de carbonato de cálcio e óxido de alumínio foi usada para formular a fase de aluminato de cálcio (CA), a fase tri-cálcio-silicato (C3S) foi formulada por queima de carbonato de cálcio e quartzo. Os pós produzidos foram investigados por difração de raios X, em seguida (CA) e (C3S) misturados com água. (CA/ C3S) comparados com MTA e biodentina para tempo de presa, microdureza, estabilidade dimensional e solubilidade. Resultados: O tempo médio de presa de (CA/C3S) foi (32,70±0,75min) que é significativamente maior que MTA e Biodentine. A microdureza média de (CA/C3S) foi (56,50±7,41VHN) que não tem diferença estática com MTA e Biodentine. Os resultados de solubilidade mostraram aumento de peso para (CA/C3S) conforme a seguir (6,29±3,05) e perda de peso para MTA e Biodentine. A porcentagem de mudança nas dimensões para (CA/C3S) aumentou como segue (0,64±0,78), enquanto diminuiu para MTA e Biodentine. Conclusão: O material experimental (CA/C3S) apresentou boa microdureza, estabilidade dimensional e aceitável tempo de presa, que pode ser melhorado em trabalhos futuros (AU)


Assuntos
Difração de Raios X , Materiais Biocompatíveis , Carbonato de Cálcio , Lasers de Estado Sólido , Óxido de Alumínio
3.
Braz. dent. sci ; 24(3): 1-8, 2021. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1281041

RESUMO

Objectives: this in vitro study was done to evaluate the effect of packable P60 composite and Tetric N-Ceram composite veneer material on fracture strength of zirconia cores. Material and Methods:Twenty four zirconium cores (Vita, Germany) with 0.7 mm thickness were fabricated by CAD/CAM technology and then subjected to air abrasion with 50 µm of Al2O3. Cores were randomly divided into three groups according to veneering material (group A: control group sandblasted with 50 µm Al2O3 veneered by IPS E-max Ceram porcelain, group C: sandblasted with 50 µm Al2O3, etching with hydrofluoric acid and veneered with P60 composite, group E: sandblasted with 50 µm Al2O3, etching with hydrofluoric acid and veneered with Tetric N-Ceram composite). All crowns were subjected to fracture strength test in the testing machine, with load application by steel ball indenter and 0.5 mm/min. cross head speed. Results: statistical analysis was carried out utilizing one-way ANOVA, LSD. The results of fracture strength value test showed the highest mean value was registered for group (A), and the lowest mean for group (E). One-way ANOVA test represented that, there was a statistically high significant different among all groups. LSD results showed a high significant difference increase in fracture resistance for Group A at p value (*p < 0.001 High significant). Conclusions: Within the limitation of this study, sandblasting zirconia core with 50 µm Al2O3 and veneering with conventional ceramic produced restoration with acceptable fracture resistance value (AU)


Objetivo: o objetivo desse estudo in vitro foi avaliar o efeito dos compósitos P60 compactáveis e material laminado de compósitos Tetric-N Ceram na resistência à fratura de núcleos de zircônia. Material e métodos:Vinte e quatro núcleos de zircônia (Vita, Germany) com 0.7 mm de espessura fabricados por tecnologia de CAD/CAM e sinterizados em alta temperatura (1450ºC por 60 min) de acordo com as instruções do fabricante. Núcleos totalmente de zircônias foram submetidos a abração com 50 µm de Al2O3. Os núcleos de zircônia foram divididos de forma randomiza em três grupos de acordo com o material de revestimento (grupo A: grupo controle jateado com 50 µm Al2O3 folheado com porcelana IPS E-max Ceram, grupo C: jateado com 50 µm Al2O3 , coberto com concentração 9,5% de ácido fluorídrico e folheado com resina composta compatível, grupo E: jateado com 50 µm Al2O3 coberto com concentração 9,5% de ácido fluorídrico e folheado com porcelana IPS E-max Ceram. Todos os espécimes (coroas) foram submetidos a teste de resistência a fratura com máquina de teste universal, essa máquina utilizou para aplicação de carga bola de aço com 6mm de diâmetro 0,5 mm/min de velocidade da cruzeta. Resultados: análise estatística foi realizada utilizando One-way ANOVA, LSD. O resultado da resistência a fratura mostra que o maior valor médio foi registrado no grupo A e a menor média para o grupo E. O resultado do teste One-Way ANOVA representaram que houve uma diferença estatisticamente alta e significante entre todos os grupos. LSD foi executada para mostrar a fonte de significância. Os resultados do LSD mostraram um aumento da diferença significativa alta na resistência à fratura para o grupo A no valor de p (p < 0.001 signicancia alta). Conclusão: Dentro das limitações desse estudo o uso convencional de jateamento com 50 µm Al2O3 e estratificação com cerâmica convencional produziu restauração com valor aceitável de resistência a fratura (AU)


Assuntos
Resinas Compostas , Óxido de Alumínio , Resistência à Flexão , Ácido Fluorídrico
5.
J. appl. oral sci ; 28: e20190371, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1056595

RESUMO

Abstract Objective This study aims to evaluate the influence of different air-abrasion pressures and subsequent heat treatment on the flexural strength, surface roughness, and crystallographic phases of highly translucent partially stabilized zirconia (Y-PSZ), and on the tensile bond strength of resin cement to Y-PSZ. Methodology Fully sintered zirconia specimens were ground with SiC paper (control) and/or air-abraded with 50 µm particles of alumina at 0.1, 0.15, 0.2, or 0.3 MPa or left as-sintered. After air-abrasion at 0.2 MPa (0.2AB), additional specimens were then heated to 1500°C, and held for one hour at this temperature (0.2AB+HT1h). Flexural strength and surface roughness were evaluated. Crystalline phase identification was also carried out using X-ray diffraction. Bonded zirconia specimens with self-adhesive resin cement were stored in distilled water at 37°C for 24 h, either with or without aging (thermal cycling 4-60°C/20000). Results were analyzed statistically by ANOVA and Tukey-Kramer tests. Results The flexural strength decreased with the increase in air-abrasion pressure, while in contrast, the surface roughness increased. The lowest flexural strength and the highest roughness value were found for the 0.2AB and 0.3AB groups, respectively. All groups contained cubic-, tetragonal ( t )-, and rhombohedral ( r )-ZrO2 phases with the exception of the as-sintered group. Upon increasing the air-abrasion pressure, the relative amount of the r -ZrO2 phase increased, with a significant amount of r -ZrO2 phase being detected for the 0.2AB and 0.3AB groups. The 0.2AB+HT1h group exhibited a similar flexural strength and t -ZrO2 phase content as the as-sintered group. However, the 0.2AB group showed a significantly higher tensile bond strength (p<0.05) than the 0.2AB+HT1h group before and after aging. Conclusion Micromechanical retention by alumina air-abrasion at 0.2 MPa, in combination with chemical bonding of a resin to highly translucent Y-PSZ using a MDP-containing resin cement may enable durable bonding.


Assuntos
Zircônio/química , Colagem Dentária/métodos , Cimentos de Resina/química , Abrasão Dental por Ar/métodos , Óxido de Alumínio/química , Valores de Referência , Propriedades de Superfície , Resistência à Tração , Difração de Raios X/métodos , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Microscopia Confocal/métodos , Resistência à Flexão , Temperatura Alta
6.
Rev. Fac. Odontol. (B.Aires) ; 35(81): 73-77, 2020. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1222960

RESUMO

El objetivo fue comparar la rugosidad de un composite nanoparticulado con diferentes técnicas de acabado y pulido. Se obtuvieron 20 discos en conformadores ad-hoc en los que se insertó un composite nanoparticulado en capas de 2mm. Se activó cada incremento durante 30s con una intensidad de 1450 mw/cm2. Todas las probetas se pulieron con la secuencia completa de discos Sof-lex a velocidad media y luego se asignaron a uno de 4 grupos (n=5) tratados de la siguiente manera: G1: sin tratamiento extra; G2: con cepillos Astrobrush y JC-SICRA-G; G3: con pasta de diamantes Diamond Gloss aplicada con fieltro; y pasta de óxido de aluminio Poligloss y fieltro; G4: igual que G3 + cepillos (igual que G2). Las superficies se evaluaron con un perfilómetro óptico tridimensional. Se registró la rugosidad promedio (Ra) en tres puntos de cada espécimen, se consideró la Ra a la media de los tres registros obtenidos. Los datos se analizaron mediante ANOVA de una vía y prueba de Tukey para comparaciones múltiples. Los resultados obtenidos fueron: G1: 132,20nm (26,16); G2: 77,20 nm (20,64); G3: 78,74 nm (10,04); G4: 66,47nm (31,08). Se encontró diferencia estadísticamente significativa entre los grupos (P=0.0017); de las comparaciones múltiples surge que G1 presentó una rugosidad media significativamente mayor que los restantes. G1>G2 (P<0.01), G1>G3 (P<0,05), G1>G4 (P<0,01). En conclusión, el uso de sistemas anexos de pulido permite lograr mayor lisura superficial. El uso de más de un sistema complementario no mejora el resultado (AU)


Assuntos
Propriedades de Superfície , Resinas Compostas , Polimento Dentário/métodos , Nanopartículas , Teste de Materiais , Interpretação Estatística de Dados , Análise de Variância , Imageamento Tridimensional , Óxido de Alumínio
7.
Araçatuba; s.n; 2020. 61 p. ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1434476

RESUMO

Objetivo: Avaliar o processo de reparo ao redor de implantes com as superfícies usinada (SU), superfície disponível comercialmente modificada por jateamento de óxido de alumínio seguido do condicionamento ácido (SJA), modificada por feixe de LASER (SL) e modificada por feixe de LASER com posterior recobrimento de hidroxiapatita através do método biomimético sem tratamento térmico (SLH). Material e Métodos: As superfícies foram analisadas através de microscopia eletrônica de varredura acoplado a espectroscopia por energia dispersiva de raios X (MEV-EDX) previamente a cirurgia. Vinte coelhos receberam randomicamente 40 implantes em suas tíbias direita e esquerda, sendo um implante de cada superfície em cada tíbia. No procedimento cirúrgicos e nos períodos de 2 e 4 semanas foi mensurado o coeficiente de estabilidade do implante através da análise de frequência por ressonância (FR), seguida da remoção por contra-torque dos implantes nos períodos de análise. Os dados obtidos foram submetidos à análise de variância e ao teste t de Tukey (FR) e Kruskal-Wallis (análise biomecânica). Resultados: MEV e EDX mostraram diferenças na topografia das superfícies. Não houve diferença estatisticamente significante entre os grupos na análise de frequência por ressonância. Foi observada diferença estatisticamente significante no torque de remoção entre o grupo SL e SLH quando comparados ao grupo SU no período de 2 semanas. Já no período de 4 semanas, foi observada diferença estatística entre as 2 superfícies experimentais SL e SLH quando comparadas as superfícies SU e SJA. Na análise histológica os grupos SL e SLH apresentaram remodelação óssea no período de 2 semanas e osso maduro no período de 4 semanas, diferente de SU e SJA que apresentaram um atraso no reparo perante as superfícies experimentais. Conclusão: Os implantes com superfície SL e SLH apresentaram propriedades topográficas, e biomecânicas superiores às das superfícies SU e SJA(AU)


Purpose: To evaluate the repair process around implants with the machined surfaces (SU), commercially available surface modified by aluminum oxide blasting followed by acid etching (SJA), modified by LASER beam (SL) and modified by LASER beam with subsequent coating of hydroxyapatite using the biomimetic method without thermal treatment (SLH). Material and Methods: The surfaces were analyzed using scanning electron microscopy coupled with dispersive energy X-ray spectroscopy (SEM-EDX) prior to surgery. Twenty rabbits randomly received 40 implants in their right and left tibiae, with one implant on each surface in each tibia. In the surgical procedure and in the periods of 2 and 4 weeks, the implant stability coefficient was measured through the resonance frequency (ISQ), followed by the removal by counter-torque of the implants in the analysis periods. The data obtained were subjected to analysis of variance and Tukey's t test (ISQ) and Kruskal-Wallis (biomechanical analysis). Results: SEM and EDX showed differences in surface topography. There was no statistically significant difference between the groups in the resonance frequency. There was a statistically significant difference in the removal torque between the SL and SLH group when compared to the SU group in the period of 2 weeks. In the 4-week period, a statistical difference was observed between the 2 experimental surfaces SL and SLH when comparing the SU and SJA surfaces. In the histological analysis, the SL and SLH groups presented bone remodeling in the period of 2 weeks and mature bone in the period of 4 weeks, unlike SU and SJA which presented a delay in repair before the experimental surfaces. Conclusion: Implants with SL and SLH surfaces showed topographic and biomechanical properties superior to those of SU and SJA surfaces(AU)


Assuntos
Animais , Coelhos , Propriedades de Superfície , Implantes Dentários , Osseointegração , Durapatita , Lasers , Coelhos , Osso e Ossos , Microscopia Eletrônica de Varredura , Análise de Variância , Remodelação Óssea , Torque , Óxido de Alumínio
8.
Braz. dent. sci ; 22(4): 520-527, 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1024654

RESUMO

Objective: Despite the increase of all-ceramic prosthesis in dental practice there is no evidence of the possibility of welding these structures if necessary. The objective of this study was to use CO2 laser (λ = 10.6 µm) as a welding agent to fuse dental polycrystalline alumina ceramic. Methods: Ceramic blocks of pre-sintered alumina were sectioned into 20 bars (10.0 x 1.5 x 1.5 mm) and sintered to the final cross section dimension of 1.2 x 1.2mm. The bars were adapted to an LHPG (Laser Heated Pedestal Growth) system device where the bars could be fixed in pairs and have their ends irradiated with CO2 laser to fusion. The ring-shaped laser beam (300 µm thickness) was directed with the aid of mirrors to reach samples' ends. The laser was continuously applied (40 W nominal power, 5 seconds). After welding, the samples were analyzed in stereomicroscope and SEM. A diffraction analysis was carried out with one sample. Results: CO2 laser was able to fuse the ceramic bars, but some of them showed some shape distortion in the fusion zone. The aspect of the fused alumina differed in color and translucency from the original sintered material. SEM evidenced the presence of porosity and voids in the center of the fusion zone. X-ray diffraction pointed to a reduction in crystallite size by two to four times in the welded region of samples. Conclusions: This study points to CO2 laser as a possible welding agent to polycrystalline alumina dental ceramic. Porosity observed in the molten zone gives cause for concern regarding weld resistance. (AU)


Objetivo: Apesar do aumento no número de próteses totalmente cerâmicas na prática clínica, não há evidência da possibilidade de se soldar essas estruturas se necessário. Este estudo testou o laser de CO2 (λ=10.6 µm) como um agente de solda para estruturas cerâmicas de alumina policristalina. Métodos: Blocos cerâmicos de alumina pré-sinterizada foram seccionados na forma de barras (10,0 x 1,5 x 1,5 mm) e sinterizados na dimensão final de 1,2 x 1,2 mm. As barras foram adaptadas a um sistema de crescimento de fibras cerâmicas (LHPG ­ Laser Heated Pedestal Growth) onde as barras foram fixadas em pares e tiveram suas extremidades irradiadas com laser de CO2 até a sua fusão. O feixe de laser foi direcionado com a ajuda de espelhos para atingir as extremidades das barras. O laser foi aplicado de forma contínua (40 W de potência nominal, 5 segundos). Depois da solda, os espécimes foram analisados em estereomicroscopia e MEV. Teste de difração foi conduzido com um espécime. Resutados: O laser de CO2 foi capaz de fundir as barras cerâmicas, mas algumas delas mostraram uma distorção da forma na zona de fusão. O aspecto da alumina soldada diferiu em cor e translucidez do material original. O MEV evidenciou a presença de porosidade no centro da zona de fusão. A difração por raio-x apontou para uma redução no tamanho dos cristalitos de duas a quatro vezes na região da solda. Conclusões: Esse estudo mostrou ser possível usar o laser de CO2 como um agente de solda para uma cerâmica policristalina de alumina. A porosidade observada na zona de fusão traz preocupação quanto à resistência da solda. (AU)


Assuntos
Materiais Dentários , Lasers de Gás , Óxido de Alumínio
9.
Rev. cient. odontol ; 6(1): 72-83, ene.-jun. 2018. ilus., tabs., grafs.
Artigo em Espanhol | LILACS | ID: biblio-998842

RESUMO

Objetivo: Comparar la resistencia a la microtensión entre dentina y resina de laboratorio Ceramage (Shofu) microa- renada, con óxido de aluminio de 25, 50 y 90 micrómetros, y un grupo sin microarenado. Materiales y métodos: Se utilizaron 12 terceros molares sanos, 3 por cada grupo. Se cortó la super- ficie de esmalte oclusal con un disco diamantado biactivo (BesQual) de 22 mm para exponer una superficie plana de dentina. Se fabricaron 12 bloques de resina de laboratorio Ceramage (Shofu) en un molde cilíndrico de teflón con un diámetro de 8 mm y una altura de 4 mm. Se tuvieron 4 grupos de estudio (3 bloques por grupo), a los que aleatoria- mente se aplicaron los siguientes trata- mientos de superficie: G1, sin microa- renar (grupo control); G2, con Al2O3 de 25 µm (Zhermack); G3, con Al2O3 de 50 µm (Bioart), y G4, con Al2O3 de 90 µm (Bioart). La cementación de los bloques a la dentina se realizó con el cemento resinoso autoadhesivo Maxcem Elite (Kerr). Se obtuvieron especímenes de aproximadamente 1 mm2 de área transversal (n = 26 especímenes por grupo) con una máquina de corte tipo IsoMet y se almacenaron en agua desti- lada por 24 horas a 37 °C. La prueba de microtensión se realizó haciendo uso de un microtensiómetro (Microtensile Tester - Bisco). Para el análisis estadís- tico se utilizaron las pruebas de Anova y Tukey, donde p < 0,001. Resultados: Los valores de la media y de la desviación estándar, para la variable resistencia a la microtensión de cada grupo, fueron las siguientes: para el G1 sin microarenado, 7,03 (± 2,94) Mpa; para el G2, microare- nado con 25 µm: 4,63 (± 1,28) Mpa; para el G3, microarenado con 50 µm: 4,56 (± 1,40) Mpa; y para el G4, microarenado con 90 µm: 5,93 (± 1,39) Mpa. Conclu- sión: La resistencia de unión entre el grupo que no recibió ningún tratamiento de superficie y el que empleó partículas de 90 µm es similar, razón por la cual se podría prescindir del microarenado como tratamiento de superficie. Además, la resistencia de unión del grupo que empleó partículas de 90 µm es superior a los grupos que emplearon 25 y 50 µm. (AU)


Objective: To compare the micro-tensile bond strength of dentine and the labora-tory composite "Ceramage" (Shofu), sand-blasted with 25, 50 and 90 micrometer aluminum oxide, and a control group not subjected to sandblasting. Materials and methods: 12 third molars were used, 3 in each group. The surface of the occlusal enamel was cut with a 22 mm bioac-tive diamond disc (BesQual), exposing a flat surface of dentin. 12 blocks of the laboratory composite Ceramage (Shofu) were manufactured in a cylin-drical Teflon mold with a diameter of 8 mm and a height of 4 mm. There were 4 study groups (3 blocks per group), upon which the following surface treatments were randomly performed: (g1): without sandblasting (c ontrol group); (g2): with 25 µm al2o3 (zhermack); (g3): with 50 µm al2o3 (bioart) and (g4): with 90 µm Al2O3 (Bioart). The cementation was made using Maxcem elite (Kerr) self-adhesive resin cement. Specimens of approximately 1 mm2 in cross-sectional area (n=26 specimens by group) were obtained using an IsoMet type cutting machine and stored in distilled water for 24 hours at 37°C. The micro-tensile test was performed using a Micro-tensile tester machine (Bisco). The Anova and Tukey tests were applied to the statis-tical analysis (p <0.001). Results: The mean and standard deviation values for the micro-tensile bond strength of each group were as follows: f or group 1 (g1) without sandblasting: 7.03 (+ 2.94) Mpa; for group 2 (G2) sandblasted with 25 µm: 4.63 (+ 1.28) Mpa; for group 3 (g3) sandblasted with 50 µm: 4.56 (+ 1.40) Mpa; and for group 4 (G4) sandblasted with 90 µm: 5.93 (+ 1.39) Mpa. Conclu-sions: The micro-tensile bond strength of the group which did not receive any surface treatment and the group subjected to 90 µm particles is similar, indicating that sandblasting could be dispensed with as a surface treatment. Also, the micro-tensile bond strength of the group subjected to 90 µm particles is superior to that of the groups subjected to 25 and 50 µm. (AU)


Assuntos
Cimentos de Resina , Dentina , Óxido de Alumínio , Polimerização
10.
Ortodoncia ; 82(163): 10-16, ene.-jun. 2018. ilus
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-994492

RESUMO

El movimiento ortodóncico es el resultado de la aplicación de fuerzas a las piezas dentarias a través de dispositivos diseñados para almacenar energía y devolverla y, así, producir el efecto deseado. El profesional actuante puede confeccionar un diagnóstico e implementar una técnica para concretar un plan de tratamiento y cumplir las satisfacciones estéticas del paciente eligiendo el zafiro como material de innovación. Sin embargo, si el bracket de zafiro no mantiene su integridad estructural en el slot donde se encuentra la información para el movimiento de la pieza dentaria, el ortodoncista debe hacer maniobras compensatorias en busca del movimiento dental óptimo para alcanzar el éxito deseado. El objetivo de este trabajo fue comparar la angulación de las paredes del slot de los brackets de zafiro y el desgaste en la superficie estructural del material en brackets sin uso clínico y utilizados luego de concluir un tratamiento. Para esto, se eligieron brackets de zafiro de todas las piezas dentarias de la arcada del maxilar superior y del inferior con uso y sin uso clínico y fueron observados al microscopio electrónico de barrido ambiental (MEB) FEI ESEM Quanta 200. Las muestras fueron lavadas con alcohol absoluto de 96 % de volumen, cepilladas de manera mecánica y secadas antes de ser introducidas en la cámara del MEB. En la etapa de observación se procedió a la construcción de medidas lineales en la imagen de la ranura del bracket desde una vista sagital. Se obtuvieron una medida interna, una media y una externa, cuyos resultados se analizaron mediante el test de normalidad de Shapiro-Wilk. En conclusión, mediante este estudio se observó que algunos brackets mantuvieron su estructura al inicio y al final de su utilización clínica, y otros presentaron una diferenciación en la medida inicial del grupo de brackets no usados clínicamente, que lleva a determinar un desgaste del ángulo interno del slot producto del deslizamiento del alambre durante el uso clínico.


The orthodontic movement is the result of the application of forces to the dental pieces through devices designed to store energy and return it and so to produce the desired effect. The acting professional can make a diagnosis and implement a technique to carry out a treatment plan and meet the aesthetic satisfactions of the patient choosing sapphire as an innovation material. However, if the sapphire bracket does not maintain its structural integrity in the slot where the information for the movement of the tooth is located, the orthodontist must make compensatory maneuvers in search of optimal dental movement to achieve the wanted success. The objective of this work was to compare the angulation of the sapphire brackets slot walls and the wear on the structural surface of the brackets material without clinical use and used after completing a treatment. For this, sapphire brackets were selected from all teeth of the upper and lower jaw arches with use and without clinical use and were observed under the environmental scanning electron microscope (ESEM) FEI ESEM Quanta 200. Samples were washed with absolute alcohol at 96% vol, mechanically brushed and dried before being introduced into the MEB chamber. In the observation phase it was carried out the construction of linear measurements in the image of the bracket slot from a sagittal view. They were obtained an internal, an average and an external measurements which results were analyzed by the Shapiro-Wilk Normality Test. In conclusion, through this study it was observed that some brackets maintained their structure at the beginning and end of their clinical use and others presented a differentiation in the initial measurement of the group of not used clinically brackets that leads to determine a wear of the internal angle of the slot owing to the sliding of the wire during clinical use.


Assuntos
Microscopia Eletrônica de Varredura , Braquetes Ortodônticos , Óxido de Alumínio , Fricção em Ortodontia
11.
Belo Horizonte; s.n; 2018. 71 p. ilus, tab.
Tese em Inglês, Português | LILACS, BBO - Odontologia | ID: biblio-914053

RESUMO

Um dos maiores desafios atuais da ciência dos materiais dentários é a obtenção de união efetiva e durável às cerâmicas de alto conteúdo cristalino. O objetivo do presente estudo foi avaliar a resistência de união, energia de superfície e tipos de fratura de dois sistemas cerâmicos após diferentes formas de tratamento de superfície associada à aplicação do plasma em pressão atmosférica. Para o estudo foram obtidas quarenta placas de zircônia (12 mm x 5 mm x 1,5 mm) de dois tipos de cerâmicas zircônia (E.max ZirCad e Calypso), polidas e limpas por ultrassom durante 5 minutos. Divididas aleatoriamente em 2 grupos de acordo com o sistema cerâmico e 4 subgrupos (n=5) de acordo com o tratamento de superfície, (I) controle (primer), (II) jateamento com partículas micrométricas de alumina (Al2O3) + primer, (III) jateamento com partículas micrométricas de alumina (Al2O3) + plasma + primer, (IV) plasma + primer. Foram confeccionados cento e vinte cilindros de resina composta (Z100), utilizando matrizes cilíndricas (1,0 mm x 3,0 mm) cimentadas com cimento resinoso, Multilink N, sobre as placas de zircônia. Os espécimes foram armazenados em água destilada durante 24 horas a 37° C, depois testados para microcisalhamento em máquina de teste Shimadzu EZ a 1,0 mm/min. Os dados obtidos foram submetidos à análise estatística para comparação entre os grupos E.max e Calypso em relação à resistência à união (força/área ­ MPa), ângulo de contato e os tipos de fratura. Os dados foram analisados pelos testes ANOVA One-Way e Kruskal-Wallis para resistência de união (p=0,003) e (p=0,005) e ângulo de contato (p<0,001) e (p<0,001). Não houve diferença significativa para os dados de fratura (p=0,145), pelo teste quiquadrado, com predomínio de fraturas mistas. Os valores de resistência de união das cerâmicas Y-TZP apresentaram maiores valores quando o plasma foi associado ao jateamento com óxido de alumínio e/ou primer e a aplicação somente do plasma não superou os valores alcançados pelas outras formas de tratamento da superfície. Essa associação resultou em menores valores dos ângulos de contato. Houve maior frequência de fraturas mistas quando realizado somente o tratamento com óxido de alumínio e quando em associação com o plasma.(AU)


One of the major challenges today in the science of dental materials is the achievement of effective and durable bonding to ceramics with high crystalline content. The objective of the present study was to evaluate the efficacy of plasma at atmospheric pressure in the adhesion of ceramic zirconia through the bond strength, surface energy and type of fracture of two ceramic systems after different forms of surface treatment associated with the application of plasma at atmospheric pressure. For the study forty zirconia plates (12 mm x 5 mm x 1.5 mm) were obtained from two zirconia ceramics (E.max ZirCad and Calypso), polished and cleaned by ultrasound for 5 minutes. Randomly divided into 2 groups according to the ceramic system and 4 subgroups (n = 5) according to the surface treatment, control (primer), primer + blasting with micrometric alumina (Al2O3) particles, primer + blasting with micrometric particles of alumina (Al2O3) + plasma, primer + plasma. One hundred and twenty cylinders of composite resin (Z-100) were made using cylindrical matrices (1.0 mm x 3.0 mm) cemented on the zirconia plates. The specimens were stored in distilled water for 24 hours at 37°C, then tested for microshear on a Shimadzu EZ test machine at 0.5 mm / min. The obtained data were submitted to statistical analysis for comparison between the E.max and Calypso groups in relation to the bond strength (strength / area - Mpa), contact angle and fracture types. The data were analyzed by ANOVA One-Way and Kruskal-Wallis tests for bond strength (p=0.003) and (p=0.005) and contact angle (p<0.001) and (p<0.001). There was no significant difference for the fracture data (p = 0.145), by the chi-square test, with a predominance of mixed fractures. The bond strength values of the Y-TZP ceramics showed higher values when the plasma was associated with blasting with aluminum oxide and / or primer and the application of only the plasma did not exceed the values reached by the other forms of surface treatment. This association resulted in lower values of contact angles. It is a higher frequency of mixed fractures when only aluminum oxide treatment is performed and when it is associated with plasma.(AU)


Assuntos
Pressão Atmosférica , Cerâmica , Materiais Dentários , Ciência dos Materiais , Fenômenos Químicos , Plasma , Cimentos de Resina , Zircônio , Óxido de Alumínio , Ligas Metalo-Cerâmicas
12.
Braz. oral res. (Online) ; 31: e4, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839528

RESUMO

Abstract The present study aimed to evaluate effects of different surface treatments and aging of composite cylinders on bond strength of composite resin repair. Thirty-two composite cylinders were produced and divided into four groups according to type of surface treatment and storage time of composite cylinder and repair. Cylinder surface of control group (Gcontrol) received no treatment before composite repair. Other groups were sandblasted with aluminum oxide (GAl2O3), followed by silane (GAl2O3sil) or adhesive (GAl2O3ad). Composite cylinders were stored in artificial saliva for either 24 hours or 1 year. Repairs were performed and stored in artificial saliva for 24 hours or 1 year and repair strength was evaluated using microtensile bond strength test. Data were submitted to Student’s t test, two-way ANOVA, and post hoc test for storage time and treatment (α = 0.05). Gcontrol group showed lower values of aging of composite cylinder and storage time of repair (24 hours or 1 year for both) compared with other groups (p < 0.05). GAl2O3ad and GAl2O3sil groups did not exhibit decreased microtensile bond strength with aged repairs (1 year; p > 0.05). Polymer degradation was significant for composite cylinders during the first year of storage in Gcontrol, GAl2O3, and GAl2O3ad groups (p < 0.05). In GAl2O3sil group, storage time of composite cylinders was not significant (p > 0.05). Aging of composite resin influenced bond strength of restoration repair for up to 1 year. Sandblasting with Al2O3, followed by application of silane layer, produced high bond strength after composite or repair aging.


Assuntos
Resinas Compostas/química , Colagem Dentária/métodos , Reparação de Restauração Dentária/métodos , Cimentos de Resina/química , Resistência à Tração , Óxido de Alumínio/química , Análise de Variância , Luzes de Cura Dentária , Teste de Materiais , Reprodutibilidade dos Testes , Saliva Artificial/química , Silanos/química , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo
13.
Rev. ADM ; 73(3): 116-120, mayo-jun.2016. tab
Artigo em Espanhol | LILACS | ID: lil-795802

RESUMO

En la actualidad existen muchos materiales dentales para la restauraciónestética, sin embargo, su tiempo de vida clínico no se conoce ampliamente. Objetivo: Identificar las publicaciones recientes de los materiales de restauración libre de metal que incluyan estudios clínicos. Metodología: La búsqueda sistemática de la literatura se realizó en bases de datos de PubMed y SciELO; se consideraron publicacionesdel 2010-2015 y que fueran investigaciones clínicas exclusivamente.Las palabras clave utilizadas fueron: Veneer crowns, dental restorationsfree metal, metal free crowns, aesthetic crowns y restauraciones libres de metal, coronas de silicato de litio, tipos de cerámicas. Resultados: Se revisaron 40 artículos y 20 cumplieron con los criterios de selección para la revisión bibliográfica. Todas las restauraciones protésicas libres de metal muestran un desempeño clínico muy similar a los tres años. Las restauraciones de zirconia y disilicato de litio por CAD mostraronel mejor éxito clínico. Conclusión: El éxito clínico de las restauracioneslibres de metal de esta revisión de la literatura muestra que van de un92.7 al 100 por ciento a tres o más años de seguimiento...


Assuntos
Humanos , Cerâmica/classificação , Facetas Dentárias/estatística & dados numéricos , Estética Dentária , Restauração Dentária Permanente/estatística & dados numéricos , Zircônio/classificação , Compostos de Lítio/classificação , Desenho Assistido por Computador/métodos , Restaurações Intracoronárias , Materiais Biocompatíveis/classificação , Materiais Dentários/classificação , Óxido de Alumínio/classificação , Interpretação Estatística de Dados , Propriedades de Superfície
14.
Braz. j. microbiol ; 47(2): 314-321, Apr.-June 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-780839

RESUMO

Abstract Little is known regarding how the increased diversity of nitrogen-fixing bacteria contributes to the productivity and diversity of plants in complex communities. However, some authors have shown that the presence of a diverse group of nodulating bacteria is required for different plant species to coexist. A better understanding of the plant symbiotic organism diversity role in natural ecosystems can be extremely useful to define recovery strategies of environments that were degraded by human activities. This study used ARDRA, BOX-PCR fingerprinting and sequencing of the 16S rDNA gene to assess the diversity of root nodule nitrogen-fixing bacteria in former bauxite mining areas that were replanted in 1981, 1985, 1993, 1998, 2004 and 2006 and in a native forest. Among the 12 isolates for which the 16S rDNA gene was partially sequenced, eight, three and one isolate(s) presented similarity with sequences of the genera Bradyrhizobium, Rhizobium and Mesorhizobium, respectively. The richness, Shannon and evenness indices were the highest in the area that was replanted the earliest (1981) and the lowest in the area that was replanted most recently (2006).


Assuntos
Microbiologia do Solo , Bactérias/isolamento & purificação , Filogenia , Plantas/microbiologia , Solo/química , Bactérias/classificação , Bactérias/genética , Óxido de Alumínio/análise , Mineração
15.
J. appl. oral sci ; 23(6): 629-636, Nov.-Dec. 2015. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-769818

RESUMO

ABSTRACT Objective The study aimed to evaluate effects of air abrasion with alumina or glass beads on bond strengths of resin cements to CAD/CAM composite materials. Material and Methods CAD/CAM composite block materials [Cerasmart (CS) and Block HC (BHC)] were pretreated as follows: (a) no treatment (None), (b) application of a ceramic primer (CP), (c) alumina-blasting at 0.2 MPa (AB), (d) AB followed by CP (AB+CP), and (e) glass-beads blasting at 0.4 MPa (GBB) followed by CP (GBB+CP). The composite specimens were bonded to resin composite disks using resin cements [G-CEM Cerasmart (GCCS) and ResiCem (RC)]. The bond strengths after 24 h (TC 0) and after thermal cycling (TC 10,000 at 4–60°C) were measured by shear tests. Three-way ANOVA and the Tukey compromise post hoc tests were used to analyze statistically significant differences between groups (α=0.05). Results For both CAD/CAM composite materials, the None group exhibited a significant decrease in bond strength after TC 10,000 (p<0.05). AB showed significantly higher bond strength after TC 10,000 than the None group, while CP did not (p<0.05). GBB exhibited smaller surface defects than did AB; however, their surface roughnesses were not significantly different (p>0.05). The AB+CP group showed a significantly higher bond strength after TC 10,000 than did the AB group for RC (p<0.05), but not for GCCS. The GBB+CP group showed the highest bond strength for both thermal cyclings (p<0.05). Conclusions Air abrasion with glass beads was more effective in increasing bond durability between the resin cements and CAD/CAM composite materials than was using an alumina powder and a CP.


Assuntos
Abrasão Dental por Ar/métodos , Óxido de Alumínio/química , Resinas Compostas/química , Desenho Assistido por Computador , Vidro/química , Cimentos de Resina/química , Análise de Variância , Cimentação/métodos , Cerâmica/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Propriedades de Superfície , Fatores de Tempo
16.
Physis (Rio J.) ; 25(4): 1361-1382, out.-dez. 2015.
Artigo em Português | LILACS | ID: lil-773453

RESUMO

O artigo discute, à luz dos paradigmas da ecologia política e da justiça ambiental, os impactos socioambientais e à saúde coletiva resultantes do processo de extração mineral no município de Itamarati de Minas-MG. Os objetivos se encerram na compreensão dos riscos e vulnerabilidades socioambientais produzidos, assim como na apreensão dos conflitos e dos cenários de injustiça ambiental, próprios a essa atividade econômica. Na primeira parte são apresentadas, de forma abreviada, algumas características do atual modelo de exploração mineral e de inserção mundial subordinada de territórios como o do município de Itamarati de Minas. Em seguida, tem lugar uma descrição da área estudada e das fontes e métodos utilizados no trabalho; em seguida, são apresentados os resultados das entrevistas. Percebeu-se que o processo de mineração de bauxita é impactante ao meio ambiente e aos modos de vida da coletividade; do mesmo modo, atua de forma negativa no processo de produção de saúde e doença, estorvando uma situação de promoção de saúde.


This paper discusses, in the light of the paradigms of political ecology and environmental justice, social, environmental and public health impacts resulting from the mining process in the city of Itamarati de Minas-MG, Brazil. The objectives are understanding risks and social and environmental vulnerability, as well as the seizure of conflicts and environmental injustice scenarios in this economic activity. The first part briefly presents some features of the current model of mineral exploration and subordinate worldwide integration of territories such as the municipality of Itamarati de Minas. Then there is a description of the study area and the sources and methods used at work; then the results of the interviews are presented. It was noticed that the bauxite mining process is impacting the environment and the community ways of life; likewise, it acts negatively in the health production process and disease, damaging a health promotion situation.


Assuntos
Humanos , Condições de Trabalho , Insegurança Hídrica , Família , Saúde Ambiental , Saúde , Saúde Pública , Vulnerabilidade a Desastres , Pesquisa Qualitativa , Meio Ambiente , Óxido de Alumínio , Fazendeiros , Mineração , Brasil
17.
Braz. j. microbiol ; 46(3): 735-742, July-Sept. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-755827

RESUMO

Native rhizobia are ideal for use as commercial legume inoculants. The characteristics of the carrier used to store the inoculants are important for the survival and symbiotic potential of the rhizobia. The objective of this study was to investigate the effects of peat (PEAT), perlite sugarcane bagasse (PSB), carboxymethyl cellulose plus starch (CMCS), and yeast extract mannitol supplemented with mannitol (YEMM) on the survival, nodulation potential and N2 fixation capacity of the native strains Sinorhizobium mexicanum ITTG R7T and Rhizobium calliandrae LBP2-1T and of the reference strain Rhizobium etli CFN42T. A factorial design (4 × 3) with four repetitions was used to determine the symbiotic potential of the rhizobial strains. The survival of the strains was higher for PEAT (46% for strain LBP2-1T, 167% for strain CFN42T and 219% for strain ITTG R7T) than for the other carriers after 240 days, except for CFN42T kept on CMCS (225%). All the strains kept on the different carriers effectively nodulated common bean, with the lowest number of nodules found (5 nodules) when CFN42T was kept on CMCS and with the highest number of nodules found (28 nodules) when ITTG R7T was kept on PSB. The nitrogenase activity was the highest for ITTG R7T kept on PEAT (4911 μmol C2H4 per fresh weight nodule h−1); however, no activity was found when the strains were kept on YEMM. Thus, the survival and symbiotic potential of the rhizobia depended on the carrier used to store them.

.


Assuntos
Fertilizantes/microbiologia , Phaseolus/crescimento & desenvolvimento , Phaseolus/microbiologia , Rhizobium/metabolismo , Sinorhizobium/metabolismo , Simbiose/fisiologia , Óxido de Alumínio/química , Carboximetilcelulose Sódica/química , Celulose/química , Manitol/química , Fixação de Nitrogênio/fisiologia , Nodulação/fisiologia , Rizosfera , Microbiologia do Solo , Dióxido de Silício/química , Solo/química , Amido/análogos & derivados , Amido/química , Leveduras/química
18.
Dental press j. orthod. (Impr.) ; 20(4): 32-38, July-Aug. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-757425

RESUMO

OBJECTIVE: To assess the color stability of five types of ceramic brackets after immersion in potentially staining solutions.METHODS: Ninety brackets were divided into 5 groups (n = 18) according to brackets commercial brands and the solutions in which they were immersed (coffee, red wine, coke and artificial saliva). The brackets assessed were Transcend (3M/Unitek, Monrovia, CA, USA), Radiance (American Orthodontics, Sheboygan, WI, USA), Mystique (GAC International Inc., Bohemia, NY, USA) and Luxi II (Rocky Mountain Orthodontics, Denver, CO, USA). Chromatic changes were analyzed with the aid of a reflectance spectrophotometer and by visual inspection at five specific time intervals. Assessment periods were as received from the manufacturer (T0), 24 hours (T1), 72 hours (T2), as well as 7 days (T3) and 14 days (T4) of immersion in the aforementioned solutions. Results were submitted to statistical analysis with ANOVA and Bonferroni correction, as well as to a multivariate profile analysis for independent and paired samples with significance level set at 5%.RESULTS: The duration of the immersion period influenced color alteration of all tested brackets, even though these changes could not always be visually observed. Different behaviors were observed for each immersion solution; however, brackets immersed in one solution progressed similarly despite minor variations.CONCLUSIONS: Staining became more intense over time and all brackets underwent color alterations when immersed in the aforementioned solutions.


OBJETIVO: avaliar a estabilidade da cor de cinco tipos de braquetes cerâmicos após imersão em soluções potencialmente corantes.MÉTODOS: noventa braquetes foram divididos em 5 grupos (n = 18) de acordo com a marca comercial dos braquetes e as soluções em que foram imersos (café, vinho tinto, Coca-Cola e saliva artificial). Os baquetes avaliados foram Transcend (3M / Unitek, Monrovia, CA, EUA), Radiance (American Ortodontia, Sheboygan, WI, EUA), Mystique (GAC International Inc., Bohemia, NY, EUA) e Luxi II (Rocky Mountain Orthodontics, Denver, CO, EUA). Alterações cromáticas foram analisadas com o uso de um espectrofotômetro de reflectância e por inspecção visual, em cinco intervalos de tempo específicos. Os momentos de avaliação foram: 24 horas (T1), 72 horas (T2), 7 dias (T3) e 14 dias (T4) de imersão nas soluções. Os resultados foram submetidos à avaliação estatística com análise de variância e correção de Bonferroni, bem como a uma análise do perfil multivariada para amostras independentes e pareadas, com nível de significância de 5%.RESULTADOS: a duração do período de imersão influenciou na alteração de cor de todos os braquetes testados, mesmo admitindo-se que essas alterações nem sempre puderam ser observadas visualmente. Diferentes comportamentos foram observados em cada solução de imersão; no entanto, braquetes imersos em um mesmo tipo de solução progrediram de forma semelhante, apesar das pequenas variações.CONCLUSÕES: a coloração se tornou mais intensa com o tempo, e todos os braquetes sofreram alteração de cor nas soluções imersas.


Assuntos
Cerâmica/química , Braquetes Ortodônticos , Materiais Dentários/química , Saliva Artificial/química , Espectrofotometria/instrumentação , Propriedades de Superfície , Fatores de Tempo , Vinho , Teste de Materiais , Bebidas Gaseificadas , Café , Cor , Corantes/química , Óxido de Alumínio/química , Imersão
19.
Arq. bras. cardiol ; 104(6): 476-485, 06/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-750695

RESUMO

Background: Circulatory power (CP) and ventilatory power (VP) are indices that have been used for the clinical evaluation of patients with heart failure; however, no study has evaluated these indices in patients with coronary artery disease (CAD) without heart failure. Objective: To characterize both indices in patients with CAD compared with healthy controls. Methods: Eighty-seven men [CAD group = 42 subjects and healthy control group (CG) = 45 subjects] aged 40–65 years were included. Cardiopulmonary exercise testing was performed on a treadmill and the following parameters were measured: 1) peak oxygen consumption (VO2), 2) peak heart rate (HR), 3) peak blood pressure (BP), 4) peak rate-pressure product (peak systolic HR x peak BP), 5) peak oxygen pulse (peak VO2/peak HR), 6) oxygen uptake efficiency (OUES), 7) carbon dioxide production efficiency (minute ventilation/carbon dioxide production slope), 8) CP (peak VO2 x peak systolic BP) and 9) VP (peak systolic BP/carbon dioxide production efficiency). Results: The CAD group had significantly lower values for peak VO2 (p < 0.001), peak HR (p < 0.001), peak systolic BP (p < 0.001), peak rate-pressure product (p < 0.001), peak oxygen pulse (p = 0.008), OUES (p < 0.001), CP (p < 0.001), and VP (p < 0.001) and significantly higher values for peak diastolic BP (p = 0.004) and carbon dioxide production efficiency (p < 0.001) compared with CG. Stepwise regression analysis showed that CP was influenced by group (R2 = 0.44, p < 0.001) and VP was influenced by both group and number of vessels with stenosis after treatment (interaction effects: R2 = 0.46, p < 0.001). Conclusion: The indices CP and VP were lower in men with CAD than healthy controls. .


Fundamento: Os índices da Potência Circulatória (PC) e Potência Ventilatória (PV) têm sido utilizados para avaliação clínica de pacientes com insuficiência cardíaca, mas nenhum estudo avaliou esses índices em pacientes com Doença Arterial Coronariana (DAC). Objetivo: Caracterizar ambos os índices em pacientes com DAC comparados a indivíduos saudáveis. Métodos: Oitenta e sete homens [grupo DAC = 42 sujeitos e, grupo controle (GC) = 45 sujeitos] com idade entre 45 e 65 anos foram incluídos. Um Teste de Exercício Cardiopulmonar (TECP) foi realizado em esteira e as seguintes variáveis foram obtidas: 1) consumo de oxigênio (VO2) pico; 2) Frequência Cardíaca (FC) pico; 3) Pressão Arterial (PA) pico; 4) duplo produto pico (PA sistólica pico x FC pico); 5) pulso de oxigênio pico (VO2 pico dividido pela FC pico); 6) eficiência ventilatória para o consumo de oxigênio (OUES); 7) eficiência ventilatória para a produção de dióxido de carbono (VE/VCO2 slope); 8) PC (VO2 pico x PA sistólica pico); e 9) PV (PA sistólica pico dividido pelo VE/VCO2 slope). Resultados: O grupo DAC apresentou valores significativamente menores das seguintes variáveis no pico do exercício: VO2 (p < 0,001), FC (p < 0,001), PA sistólica (p < 0,001), duplo produto (p < 0,001), pulso de oxigênio (p = 0,008), OUES (p < 0,001), PC (p < 0,001) e PV (p < 0,001), e valores significativamente maiores de PA diastólica (p = 0,004) e VE/VCO2 slope (p < 0,001) em relação ao GC. Uma análise de regressão pelo método stepwise mostrou que a PC foi influenciada pelo grupo (R2 = 0,44, p < 0,001) e a PV tanto pelo grupo quanto pelo número de vasos com estenose pós tratamento (efeito de interação: R2 = 0,46, p < 0,001). Conclusion: Os índices da PC e PV foram menores em homens com DAC comparados ao GC, podendo dessa forma ser utilizados na caracterização dessa população. .


Assuntos
Animais , Humanos , Óxido de Alumínio/toxicidade , Moléculas de Adesão Celular/metabolismo , Adesão Celular/efeitos dos fármacos , Endotélio Vascular/efeitos dos fármacos , Nanopartículas Metálicas/toxicidade , Células Cultivadas , Moléculas de Adesão Celular/genética , Relação Dose-Resposta a Droga , Selectina E/genética , Selectina E/metabolismo , Endotélio Vascular/metabolismo , Endotélio Vascular/ultraestrutura , Expressão Gênica/efeitos dos fármacos , Molécula 1 de Adesão Intercelular/genética , Molécula 1 de Adesão Intercelular/metabolismo , Microscopia Eletrônica de Transmissão/métodos , Monócitos/efeitos dos fármacos , Monócitos/metabolismo , Monócitos/ultraestrutura , Tamanho da Partícula , RNA Mensageiro/metabolismo , Suínos , Molécula 1 de Adesão de Célula Vascular/genética , Molécula 1 de Adesão de Célula Vascular/metabolismo
20.
Dental press j. orthod. (Impr.) ; 20(2): 61-67, Mar-Apr/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-745853

RESUMO

OBJECTIVE: To assess enamel surface under scanning electron microscopy (SEM) after resin removal and enamel polishing procedures following brackets debonding, as well as compare the time required for these procedures. METHODS: A total of 180 deciduous bovine incisors were used. The enamel surface of each tooth was prepared and brackets were bonded with light cured Transbond XT composite resin. Brackets were removed in a testing machine. The samples were randomized and equally distributed into nine groups according to the resin removal and polishing technique: Group 1, 30-blade tungsten carbide bur in high speed; Group 2, 30-blade tungsten carbide bur in high speed followed by a sequence of 4 Sof-lex polishing discs (3M); Group 3, 30-blade tungsten carbide bur in high speed followed by Enhance tips (Dentsply). All groups were subdivided into (a) unpolished; (b) polished with aluminum oxide paste; and (c) polished with water slurry of fine pumice. Subsequently, the enamel surface was assessed and statistical analysis was carried out. RESULTS: There were statistically significant differences in enamel roughness and removal time among all groups. Groups 3a, 3b and 3c appeared to be the most efficient methods of removing resin with low damages to enamel. Groups 2a, 2b and 2c were the most time consuming procedures, and Group 2a caused more damages to enamel. CONCLUSION: The suggested protocol for resin removal is the 30-blade tungsten carbide bur in high speed followed by Enhance tips and polishing with aluminum oxide paste. This procedure seems to produce less damages and is less time consuming. .


OBJETIVO: avaliar a superfície do esmalte, por meio de microscopia eletrônica de varredura, após descolagem de braquetes e o polimento do esmalte, com diferentes técnicas de remoção de resina, bem como comparar o tempo necessário para a realização do procedimento. MÉTODOS: foram utilizados 180 dentes bovinos decíduos. A superfície do esmalte dos dentes foi preparada e realizada a colagem dos braquetes com resina Transbond XT. Os braquetes foram removidos em máquina de ensaio mecânico. Foram formados, aleatoriamente, nove grupos, de acordo com o tipo de remoção da resina e de polimento, sendo: Grupo 1, broca de tungstênio de 30 lâminas em alta rotação; Grupo 2, broca de tungstênio de 30 lâminas em alta rotação e sequência de quatro discos Soflex (3M); Grupo 3, broca de tungstênio de 30 lâminas em alta rotação e pontas de acabamento Enhance (Dentsply). Todos os grupos foram subdividido em (a) sem polimento, (b) polimento com pasta de óxido de alumínio e (c) polimento com pedra-pomes. As superfícies foram avaliadas e foi realizada análise estatística. RESULTADOS: houve diferença estatística entre os grupos em relação à rugosidade de superfície e ao tempo de remoção. Os grupos 3a, 3b e 3c demonstraram ser os métodos mais eficientes de remoção da resina, promovendo pouco dano à superfície do esmalte. Os grupos 2a, 2b e 2c consumiram maior tempo de procedimento, e o grupo 2a causou maior dano ao esmalte. CONCLUSÃO: sugere-se como protocolo de remoção o uso de broca de tungstênio de 30 lâminas para remoção do maior volume da resina, pontas de acabamento Enhance e polimento com a pasta de óxido de alumínio, por produzirem menor dano. .


Assuntos
Animais , Bovinos , Descolagem Dentária/métodos , Esmalte Dentário/ultraestrutura , Profilaxia Dentária/métodos , Braquetes Ortodônticos , Cimentos de Resina/química , Condicionamento Ácido do Dente/métodos , Óxido de Alumínio/química , Equipamentos Odontológicos de Alta Rotação , Colagem Dentária/métodos , Descolagem Dentária/instrumentação , Profilaxia Dentária/instrumentação , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Propriedades de Superfície , Silicatos/química , Fatores de Tempo , Compostos de Tungstênio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...