Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
1.
J. oral res. (Impresa) ; 12(1): 1-11, abr. 4, 2023. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1442654

RESUMO

Introduction: Proximal lesions that exceed the cement enamel limit (ACE) under the gingival margin complicate impressions and the adhesive technique. Compare the magnitude of micro infiltration between conventional resin and bulk fill resin in the cervical margin relocation technique. Materials and Methods: 48 samples of human teeth re-ceived two preparations: occluso-mesial (OM) and occluso-distal (OD) under LAC; first they received the cervical margin relocation technique (RMC) with bulk fill and conventional resin; then restored with semi-direct resinous inlays. Sample analysis: immersion in 50% colloidal silver nitrate solution, 24 hours, 37°C and cut mesiodistally. Observed under a stereoscopic magnifying glass to assess dye penetration and digitally photographed, analyzed with "Image J" software. Results: Sample of 96 cavities in two groups of 48 units; control group restored with conventional resin with incremental technique and study group restored with bulk fill resin, mono-incremental technique. Probabilistic sampling. No statistically significant diffe-rences in percentage of microinfiltrated area between Filtek™ Z250™ and Filtek™ Bulk Fill™ (p-value= 0.68). Discussion: Various studies show that the presence of marginal microinfiltration exist independent of: restorative technique, consistency, adhesive mechanism and polyme-rization technique. The research carried out is no exception, observing a similar degree for both systems. Conclusions: Results allow us to conclude that conventi-onal resin and bulk fill resin did not show significant differences in microleakage percentages for the RMC technique. Outside the study framework, bulk fill resins would have comparative advantages; better behavior against light in depths greater than 2 mm, less sensitivity to the "C" factor, and less clinical time.


Introducción: Las lesiones proximales que superan el límite cemento esmalte (ACE) por debajo del margen gingival complican las impresiones y la técnica adhesiva. Comparar la magnitud de la microinfiltración entre la resina convencional y la resina de relleno en la técnica de reubicación del margen cervical. Materiales y Métodos: 48 muestras de dientes humanos recibieron dos preparaciones: ocluso-mesial (OM) y ocluso-distal (OD) bajo LAC, primero recibieron la técnica de reubicación del margen cervical (RMC) con relleno en bloque y resina convencional; luego restaurado con incrustaciones resinosas semidirectas. Análisis de la muestra: inmersión en solución de nitrato de plata coloidal al 50%, 24 horas, 37°C y corte mesiodistal. Observado bajo una lupa estereoscópica para evaluar la penetración del tinte y fotografiado digitalmente, analizado con el software "Image J". Resultados: Muestra de 96 cavidades en dos grupos de 48 unidades; grupo control restaurado con resina convencional con técnica incremental y grupo estudio restaurado con resina bulk fill, técnica mono-incremental. Muestreo probabilístico. No hubo diferencias estadísticamente significativas en el porcentaje de área microinfiltrada entre Filtek™ Z250™ y Filtek™ Bulk Fill™ (p-value = 0,68) Discusión: Diversos estudios evidencian presencia de microinfiltración marginal, independiente de técnica restauradora, consistencia, mecanismo adhesivo y técnica polimerizadora. La investigación realizada no es excepción, observándose grado similar para ambos sistemas. Conclusiones: Los resultados permiten concluir que resina convencional y resina bulk fill no presentaron diferencias significativas en porcentajes de microinfiltración para técnica RMC. Fuera del marco del estudio, resinas bulk fill tendrían ventajas comparativas; mejor comportamiento frente a la luz en profundidades superiores a 2 mm, menor sensibilidad al factor "C", y menor tiempo clínico.


Assuntos
Humanos , Resinas Sintéticas , Infiltração Dentária , Restauração Dentária Permanente , Polimento Dentário/métodos
2.
Natal; s.n; 21 out. 2022. 126 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1532447

RESUMO

Recursos digitais, como a manufatura subtrativa (fresagem CAD-CAM) e a manufatura aditiva (impressão 3D) podem promover significativos avanços, reduzindo o tempo e o custo de produção de próteses totais (PTs). Assim, este estudo objetiva investigar as características superficiais (rugosidade e ângulo de contato), propriedades mecânicas (resistência mini-flexural) e a adesão de biofilme sobre polímeros de PMMA pré-polimerizado para fresagem CAD-CAM e sobre resinas para impressão 3D utilizados na fabricação de bases de PTs, bem como propor um fluxo de trabalho inovador para abreviar e simplificar as etapas de confecção de PTs. Para a análise in vitro, foram fabricados um total de 60 discos e 40 barras distribuídas igualmente em quatro grupos: fresagem CAD-CAM (GF), impressão 3D (GI) e PMMA convencional termopolimerizado por ciclo longo (GCL) ou por energia de micro-ondas (GCM). A rugosidade foi determinada pelo valor de Ra; o ângulo de contato foi medido pelo método da gota séssil; o teste de resistência à mini-flexão foi obtido por teste de flexão de três pontos, enquanto o comportamento frente à formação de biofilme foi analisado através da adesão de biofilme de C. albicans. Os dados foram analisados por meio de estatística descritiva e analítica (α = 0,05). Os resultados mostraram que o GI apresentou a maior rugosidade superficial (Ra: 0,317 ± 0,151µm) e os menores valores de resistência à miniflexão (57,23 ± 9,07MPa) e o GF apresentou a menor adesão de biofilme de C. albicans (log UFC/mL: 3,74 ± 0,57) e maior média de resistência à mini-flexão (114,96 ± 16,23 MPa). Não houve diferença estatística entre o GF e os grupos convencionais para rugosidade, ângulo de contato e resistência à mini-flexão. A patente de inovação desenvolvida estabeleceu um novo fluxo de trabalho para confecção de próteses totais através de um protocolo de três consultas em que foram feitas as moldagens anatômicas na 1ª sessão, juntamente com o registro do suporte labial, plano oclusal e linhas de referência para subsidiar a montagem dos dentes superiores. Uma prótese-teste foi confeccionada por meio de procedimentos convencionais ou CAD-CAM e avaliada na 2ª consulta, permitindo observar o resultado estético, executar a moldagem funcional e realizar o registro da relação maxilo-mandibular, fornecendo referências precisas para a confecção da prótese inferior. Com base nos resultados da fase in vitro deste estudo, os corpos-de-prova obtidos a partir de disco para fresagem CAD-CAM apresentaram resistência flexural e propriedades superficiais semelhantes às resinas convencionais e mostraram um comportamento inibidor da adesão de C. albicans, enquanto os espécimes produzidos por impressão 3D exibiram a menor resistência à flexão e a maior rugosidade da superfície. O dispositivo inovador apresentado para a execução das etapas clínicas relacionadas à fabricação de PTs mostrou-se efetivo para abreviar e simplificar as técnicas disponíveis, apresentando confiabilidade e previsibilidade para produção de PTs em número de sessões reduzido (AU).


Digital features like subtractive and additive manufacturing can promote breakthroughs by reducing the time and cost of making complete dentures (CDs). Thus, this study aims to investigate surface characteristics (roughness and contact angle), mechanical properties (mini-flexural strength), and biofilm adhesion on computer-aided design/computer-aided manufacturing (CAD-CAM) PMMA polymer, and threedimensional (3D) printed resin for denture´s base fabrication as well as to propose an innovative workflow. For in vitro analysis, a total of 60 discs and 40 rectangular specimens were fabricated from one CAD-CAM pre-polymerized PMMA disc (GF), one 3D-printed (GI), and two conventional heat-polymerized (GCL and GCM) materials for denture base fabrication. Roughness was determined by the Ra value; the contact angle was measured by the sessile drop method; the mini-flexural strength test was a three-point bending test while the biofilm formation inhibition behavior was analyzed through C. albicans adhesion. The data were analyzed using descriptive and analytical statistics (α = 0.05). Results showed that GI specimens presented the highest surface roughness (Ra: 0.317 ± 0.151 µm) and lowest mini-flexural strength values (57.23 ± 9.07 MPa) and the GF showed the lowest C. albicans adhesion (log CFU/mL: 3.74 ± 0.57) and highest mini-flexural strength mean (114.96 ± 16.23 MPa). There was no statistical difference between GF and conventional groups for roughness, contact angle, and mini-flexural strength. In turn, the presented novel workflow for complete dentures fabrication reached a three appointments protocol in which preliminary impressions were made in the 1st session, all together to maxillary registration of lip support, occlusal plane, and reference lines for teeth arrangement. A trial denture was manufactured and evaluated by the 2nd appointment through conventional or CAD-CAM procedures, allowing esthetics evaluation, final impression, and maxillomandibular relationship record and providing precise references for final dentures fabrication. Based on the findings of this in vitro study, GF presented surface and mechanical properties similar to conventional resins and show improved behavior preventing C. albicans adhesion, while GI specimens exhibited the lowest flexural strength, and highest surface roughness. The proposed device for CD´s fabrication clinical procedures reached feasibility and by simplifying available techniques, this protocol could achieve reliability and predictability to produce complete dentures with reduced working time (AU).


Assuntos
Resinas Sintéticas , Desenho Assistido por Computador/instrumentação , Prótese Total/tendências , Tecnologia Digital , Técnicas In Vitro/métodos , Placa Dentária/prevenção & controle , Fluxo de Trabalho , Testes Mecânicos/métodos
3.
Braz. dent. sci ; 25(2): 1-10, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1368117

RESUMO

Objective: The aim of this study was to evaluate the effectiveness of different adhesives on the shear bond strength (SBS) of brackets bonded to different ceramic materials. Material and Methods: Fifty disk-shaped specimens were produced from lithium disilicate (IPS e.max CAD) and monolithic zirconia (Cercon) materials. Each specimen was polished with a three-step diamond polishing system. The polished ceramic surfaces were conditioned with universal bonding resin (Assure Plus) without pre-treatment, except for two specimens. Central brackets were bonded onto different ceramic specimens with different adhesives as follows: group 1: conventional adhesive onto the lithium disilicate; group 2: one-step adhesive onto the lithium disilicate; group 3: conventional adhesive onto the monolithic zirconia; group 4: one-step adhesive onto the monolithic zirconia. After thermal cycling, the specimens were subjected to the SBS test. The adhesive remnant index (ARI) scores were also recorded to evaluate bond failure type. Kruskal­Wallis and Mann-Whitney U tests were used for statistical analysis. Results: There were statistically significant differences among the SBS values (p˂0.05). The monolithic zirconia group with universal bonding resin and conventional orthodontic adhesive demonstrated the highest SBS value (6.34 MPa) and ARI scores. The lithium disilicate group showed the lowest SBS value (2.17 MPa) with the same protocol. No adhesive remained on the lithium disilicate specimens. Conclusion: One-step adhesive and universal bonding resin combination should not be considered as an alternative for lithium disilicate and monolithic zirconia restorations. Conventional adhesive and universal bonding resin application can be effective on non-pretreated ceramic surfaces during orthodontic bonding (AU)


Objetivo: o objetivo deste estudo foi avaliar a eficácia de diferentes adesivos na resistência ao cisalhamento (SBS) de bráquetes colados a diferentes materiais cerâmicos. Material e métodos: Cinquenta espécimes em forma de disco foram produzidos a partir de materiais de dissilicato de lítio (IPS e.max CAD) e zircônia monolítica (Cercon). Cada amostra foi polida com um sistema de polimento de diamante de três passos. As superfícies cerâmicas polidas foram condicionadas com resina de ligação universal (Assure Plus) sem pré-tratamento, exceto para dois corpos-de-prova. Bráquetes centrais foram colados em diferentes corpos de prova cerâmicos com diferentes adesivos da seguinte forma: grupo 1: adesivo convencional sobre dissilicato de lítio; grupo 2: adesivo de uma etapa sobre o dissilicato de lítio; grupo 3: adesivo convencional sobre zircônia monolítica; grupo 4: adesivo de uma etapa sobre a zircônia monolítica. Após a ciclagem térmica, os corpos-de-prova foram submetidos ao teste SBS. Os escores do índice de remanescente adesivo (ARI) também foram registrados para avaliar o tipo de falha de adesão. Os testes U de Kruskal-Wallis e Mann-Whitney foram usados para análise estatística. Resultados: Houve diferenças estatisticamente significativas entre os valores de SBS (p˂0,05). O grupo de zircônia monolítica com resina de colagem universal e adesivo ortodôntico convencional demonstrou o maior valor de SBS (6,34 MPa) e escores de ARI. O grupo de dissilicato de lítio apresentou o menor valor de SBS (2,17 MPa) com o mesmo protocolo. Nenhum adesivo permaneceu nas amostras de dissilicato de lítio. Conclusão: A combinação de adesivo de uma etapa e resina de ligação universal não deve ser considerada como uma alternativa para restaurações de dissilicato de lítio e zircônia monolítica. A aplicação de adesivo convencional e resina de colagem universal podem ser eficazes em superfícies de cerâmica não pré-tratadas durante a colagem ortodôntica (AU)


Assuntos
Resinas Sintéticas , Braquetes Ortodônticos , Adesivos Dentinários , Resistência ao Cisalhamento
4.
Odovtos (En línea) ; 23(3)dic. 2021.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386563

RESUMO

ABSTRACT: CAD/CAM blocks are widely used in dental restorations around the world. This study aimed to investigate the effects of different polishing and finishing systems on surface roughness and color change of resin-based CAD/CAM blocks. In this study, material samples of 2×7×12mm were prepared. In three different experimental groups, surface polishing was carried out with one-step, two-step and multi-step polishing systems. The samples in one subgroup of each experimental group were polished with the diamond paste. Once the initial roughness and color values of the samples were measured using a profilometer and a spectrophotometer, the samples were immersed in coffee. Surface roughness and color change (ΔE00) results were statistically analyzed using two-way variance analysis (ANOVA). Finishing and polishing systems created significantly different levels of surface roughness on the hybrid ceramic block (Vita Enamic) but not on the composites block (Brilliant Crios, Grandio Blocs). While the two-step and multi-step finishing and polishing systems produced the lowest color change on hybrid ceramic blocks, one-step and two-step systems achieved this on composite blocks (p<0.05). In all test groups, the supplementary polishing performed after regular polishing procedures helped us reduce the surface roughness and color change on CAD/CAM blocks. The findings obtained in this study suggest that one and two-step polishing systems are more suitable for resin-based composite CAD/CAM blocks; for hybrid ceramic CAD/CAM blocks, on the other hand, two and multi-step finishing and polishing systems seem to be more efficient concerning lower surface roughness and resistance to color changes.


RESUMEN: Los bloques CAD/CAM son ampliamente utilizados en las restauraciones dentales, alrededor del mundo. El objetivo de este estudio es investigar los efectos de diferentes sistemas de pulido y acabado sobre la rugosidad de la superficie y el cambio de color de los bloques CAD/CAM de resina. En este estudio se prepararon muestras de material de 2×7×12mm. El pulido de la superficie se llevó a cabo en tres grupos experimentales con sistemas de pulido de un paso, de dos pasos y de varios pasos. Las muestras de un subgrupo de cada grupo experimental se pulieron con la pasta de diamante. Una vez medidos los valores iniciales de rugosidad y color de las muestras mediante un perfilómetro y un espectrofotómetro, las muestras se sumergieron en café. Los resultados de la rugosidad superficial y el cambio de color (ΔE00) se analizaron estadísticamente mediante un análisis de varianza de dos vías (ANOVA). Los sistemas de acabado y pulido crearon niveles de rugosidad superficial significativamente diferentes en el bloque cerámica híbrida (Vita Enamic) pero no en el bloque de composites (Brilliant Crios, Grandio Blocs). Mientras que los sistemas de acabado y pulido de dos y varios pasos produjeron el menor cambio de color en los bloques de cerámica híbrida, los sistemas de un paso y dos pasos lo consiguieron en los bloques de composite (p<0,05). En todos los grupos de prueba, el pulido suplementario realizado después de los procedimientos de pulido regulares nos ayudó a reducir la rugosidad de la superficie y el cambio de color en los bloques CAD/CAM. Los hallazgos obtenidos en este estudio sugieren que los sistemas de pulido de uno y dos pasos son más adecuados para los bloques CAD/CAM de resina; en cambio, para los bloques CAD/CAM de cerámica híbrida, los sistemas de acabado y pulido de dos y varios pasos parecen ser más eficientes en lo que respecta a la menor rugosidad de la superficie y la resistencia a los cambios de color.


Assuntos
Resinas Sintéticas , Cor , Restauração Dentária Permanente/instrumentação
5.
Int. j interdiscip. dent. (Print) ; 14(1): 100-104, abr. 2021. tab
Artigo em Espanhol | LILACS | ID: biblio-1385175

RESUMO

RESUMEN: Introducción: Con el fin de prevenir la progresión de la caries interproximal no cavitada en dientes temporales, se ha generalizado el uso de estrategias mínimamente invasivas como la aplicación de sellantes, barniz de flúor o la resina infiltrante, ya sea combinadas o como monoterapia. Pese a lo anterior, hay incertidumbre con relación al efecto de la infiltración de resina en combinación con el barniz de flúor en dientes temporales. Métodos: Realizamos una búsqueda en Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud, la cual es mantenida mediante el cribado de múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Extrajimos los datos desde las revisiones identificadas, analizamos los datos de los estudios primarios, realizamos un metaanálisis y preparamos una tabla de resumen de los resultados utilizando el método GRADE. Resultados y conclusiones: Se identificaron nueve revisiones sistemáticas que en conjunto incluyeron tres estudios primarios que corresponden a ensayos clínicos aleatorizados. Se concluye que la infiltración de resina probablemente reduce el riesgo de la progresión de la caries interproximal no cavitada en dientes temporales. No se encontraron estudios que evaluaran los eventos adversos. Palabras claves: caries, infiltración de resina, caries interproximal, barniz de flúor, tratamiento mínimamente invasivo, Epistemonikos, GRADE.


ABSTRACT: Introduction: Minimally invasive techniques are widely used in non-cavitated interproximal caries treatment in primary dentition. Sealants, fluoride varnish, or resin infiltration can be applied in conjunction or as monotherapy. There is uncertainty regarding the effect of resin infiltration in conjunction with fluoride varnish in primary dentition. Methods: We searched in Epistemonikos, the largest database of systematic reviews in health, which is maintained by screening multiple information sources, including MEDLINE, EMBASE, Cochrane, among others. We extracted data from the systematic reviews, reanalyzed data of primary studies, conducted a meta-analysis and generated a summary of findings table using the GRADE approach. Results and conclusions: We identified 9 systematic reviews including three studies overall, of which all were randomized trials. We conclude that resin infiltration plus fluoride varnish probably decreases the risk of progression of non-cavitated interproximal caries in primary dentition. No studies were found that looked at adverse effects.


Assuntos
Humanos , Resinas Sintéticas , Cárie Dentária , Dentição
6.
J. oral res. (Impresa) ; 10(1): 1-7, feb. 24, 2021. ilus, graf, tab
Artigo em Inglês | LILACS | ID: biblio-1282565

RESUMO

Objective: The aim of this study was to assess the micro-push-out bond strength of a mineral-based root canal sealer, BioRoot RCS in canals prepared by K3XF rotary systems of two different tapers. Material and Methods: Eighty caries free maxillary central incisors were used in this study. The samples were allocated into 4 groups (n=20) according to the root canal sealer and taper of the rotary instruments. The samples were obturated using single cone obturation technique. From each root 1mm thick slices at coronal, middle and apical thirds were collected using hard tissue microtome under continuous water coolant. Push-out tests were done for these sections using a Universal testing machine (INSTRON 8801) at a crosshead speed of 1mm/min. One-way analysis of variance (ANOVA) was used to compare the bond strengths within groups and Tukey's multiple post hoc analysis was used for pair-wise comparison of bond strengths. Results: AH Plus exhibited higher micro-push-out bond strength than BioRootRCS though they did not differ significantly (p>0.05). Preparation of root canals with 6% taper rotary instruments showed higher bond strength than 4% though they did not differ significantly (p>0.05). Conclusion: There was no significant difference between micro-push-out bond strength values of BioRoot RCS and AH Plus. The bond strength values were high in 6% taper canals than 4% canals though the difference was not significant statistically.


Objetivo: El objetivo de este estudio fue evaluar la fuerza de unión por micro-expulsión de un sellador de conductos radiculares de base mineral, BioRoot RCS, en conductos preparados por sistemas rotativos K3XF con dos conos diferentes. Material y Métodos: En este estudio se utilizaron 80 incisivos centrales superiores libres de caries. Las muestras se distribuyeron en cuatro grupos (n = 20) de acuerdo al sellador del conducto radicular y al cono de los instrumentos rotativos. Las muestras se obturaron mediante la técnica de obturación de un solo cono. De cada raíz se recogieron rodajas de 1 mm de grosor en los tercios coronal, medio y apical utilizando un micrótomo de tejido duro con refrigeración continua por agua. Posteriormente, se realizó una prueba de expulsión para estas secciones utilizando una máquina de prueba universal (INSTRON 8801) a una velocidad del cabezal transversal de 1mm/min. Se utilizó el análisis de varianza unidireccional (ANOVA) para comparar las resistencias de la unión dentro de los grupos y el análisis post hoc multiple de Tukey se utilizó para la comparación por pares de las resistencias de la unión. Resultados: AH Plus exhibió una fuerza de unión de micro-expulsión más alta que BioRootRCS, aunque no difirieron significativamente (p>0,05). La preparación de los conductos radiculares con instrumentos rotativos ahusados al 6% mostró una fuerza de unión superior al 4%, aunque no difirieron significativamente (p>0,05). Conclusión: No hubo diferencias significativas entre los valores de fuerza de unión de micro-expulsión de BioRoot RCS y AH Plus. Los valores de la fuerza de unión fueron más altos en canales cónicos al 6% que en canales al 4%, aunque la diferencia no fue significativa estadísticamente.


Assuntos
Humanos , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular/métodos , Adesivos Dentinários , Resistência à Flexão , Resinas Sintéticas , Análise de Variância , Preparo de Canal Radicular , Cavidade Pulpar , Resinas Epóxi/química , Minerais
7.
São José dos Campos; s.n; 2021. 116 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1362020

RESUMO

Os objetivos deste estudo foram comparar três materiais bioativos a uma resina bulk fill convencional (controle), quanto à adesão bacteriana e alterações ópticas, quando expostos a solução corante e escovação simulada; como também, avaliar o esmalte adjacente a restaurações com esses materiais, quando submetidas ao envelhecimento térmico e a desafio cariogênico. Para determinação da adesão bacteriana (fase 1), foram confeccionadas 10 amostras de cada grupo: AB: Activa Bioactive Restorative (PulpdentTM Corporation, USA); BB: Beautifil Bulk (Shofu inc., Kyoto, Japan); EQ: Equia Forte (GC América Inc., Illinois, EUA) e FBC: Filtek Bulk Fill (3M ESPE, Saint Paul, Minessota, EUA 3M). Após a polimerização, as amostras foram armazenadas por 48h e então expostas a cepa padrão de Streptococcus mutans (UA 159) e determinado o número de unidades formadoras de colônia (UFC/ml). Foram então autoclavadas e submetidas diariamente a ciclos de pigmentação por café e escovação simulada, durante 30 dias, seguidos de uma segunda adesão bacteriana. Alterações de cor e translucidez foram avaliadas após esses ciclos. Os dados foram submetidos à ANOVA dois fatores e teste de Tukey (5%). Para avaliação do esmalte (fase 2), foram utilizadas as faces vestibulares e linguais de 50 terceiros molares humanos distribuídas aleatoriamente em 5 grupos (n=20): grupo EH: esmalte hígido (controle) e, 4 grupos que receberam preparos cavitários padronizados restaurados com os mesmos materiais utilizados na fase 1. Os espécimes foram expostos à termociclagem (10.000 ciclos) e desafio cariogênico. A microdureza do esmalte foi medida inicialmente, após termociclagem e após o desafio cariogênico. Os dados foram submetidos a ANOVA dois fatores de medidas repetidas e teste de Tukey (5%). Os resultados apresentaram diferenças estatisticamente significantes entre os grupos para as adesões bacterianas; sendo que na primeira, o grupo AB (6,2 log) apresentou o menor valor. Na segunda adesão, o grupo FBC manteve seu crescimento estável (7,5 log). Os grupos AB e EQ (9,4 e 9,2 log) apresentaram médias superiores as da primeira adesão (6,2 e 7,6 log respectivamente). O grupo BB (6,7 log) mostrou a menor adesão bacteriana. Diferenças na cor não foram estatisticamente significantes entre os grupos, no entanto, todos materiais mostraram alteração de cor perceptível (∆E> 2,7) após os ciclos de exposição ao café e escovação. A translucidez foi estatisticamente diferente entre os grupos, mas não foi influenciada pelos ciclos. A microdureza do esmalte diminuiu para todos os grupos após a termociclagem. Os grupos FBC e EH apresentaram as menores médias de microdureza (178,78/ 202,83 kgf); os grupos AB e BB (240,82/ 265,34 kgf), foram estatisticamente semelhantes; e o grupo EQ apresentou a maior média (274,18 kgf). Uma diminuição da microdureza aconteceu após o desafio cariogênico, exceto para o grupo EQ (244,73 kgf). Os grupos FBC e EH (117,18/ 112,97 kgf), não apresentaram diferenças estatísticas entre eles, com as menores médias de microdureza; e, os grupos BB e AB (211,32/ 171,14 kgf) apresentaram diferenças estatísticas em relação aos demais grupos. Podemos concluir que: os materiais bioativos interferiram na adesão bacteriana por Streptococcus mutans, e foram susceptíveis aos ciclos de pigmentação e escovação; a imersão no café e escovação simulada alteraram a cor, mas não a translucidez de todos os materiais; a termociclagem reduziu a dureza superficial do esmalte adjacente a todas as restaurações nesse estudo; e que, o desafio cariogêncio reduziu a dureza do esmalte exceto para o grupo EQ, que apresentou manutenção da sua dureza, mostrando seu potencial de influenciar a resistência do esmalte à desmineralização.


The aim of this study was to compare three bioactive materials to a conventional resin, regarding bacterial adhesion and optical changes, when exposed to dye solution and simulated brushing; as well as evaluate the enamel adjacent to restorations with these materials, when submitted to thermal aging and cariogenic challenge. To determine bacterial adhesion (phase 1), 10 samples of each material were prepared: AB: Activa Bioactive Restorative (Pulpdent™ Corporation, USA); BB: Beautifil Bulk (Shofu inc., Kyoto, Japan); EQ: Equia Forte (GC America Inc., Illinois, USA) and FBC: Filtek Bulk Fill (3M ESPE, Saint Paul, Minnesota, USA 3M). After 48 hours the samples were exposed to a standard strain of Streptococcus mutans (UA 159) and the number of colony forming units (CFU/ml) determined. They were then autoclaved and submitted daily to coffee pigmentation and simulated brushing cycles, for 30 days, followed by a second bacterial adhesion. Color and translucency changes were assessed after these cycles. Data were submitted to two-way ANOVA and Tukey test (5%). For enamel evaluation (phase 2), buccal and lingual surfaces of 50 human third molars were randomly distributed into 5 groups (n=20): EH group: sound enamel (control) and 4 groups that received standardized cavity preparations restored with the same materials in phase. Specimens were exposed to thermocycling (10,000 cycles) and cariogenic challenge. Enamel microhardness was measured initially, after thermocycling and after cariogenic challenge. Data were submitted to Two-way Repeated Measures ANOVA and Tukey test (5%). Bacterial adhesion results showed statistically significant differences among groups; in the first adhesion, AB group (6.2 log) presented the lowest bacterial growth. In the second one, group FBC maintained its growth (7.5 log). AB and EQ groups (9.3 log) presented higher growth than before the treatments (6.2 and 7.6 log respectively). BB group (6.7 log) showed the lowest bacterial adhesion. Color differences were not statistically significant among groups; however, noticeable color change (∆E> 2.7) was seen for all materials after the coffee and brushing cycles. Translucency was statistically different among the groups but was not influenced by the cycles. Enamel microhardness decreased for all groups after thermocycling. FBC group and EH group, showed the lowest microhardness averages (178.78/202.83 kgf); AB and BB groups (240.82/265.34 kgf) were statistically similar; and EQ group had the highest average (274.18 kgf). A decrease in microhardness occurred after the cariogenic challenge for all materials, except for the EQ group (244.73 kgf). FBC and EH groups (117.18/112.97 kgf) did not present statistical differences between them, showing the lowest microhardness averages; and, groups BB and AB (211.32/ 171.14 kgf), were statistically different to the other groups. We can conclude that: bioactive materials interfered with bacterial adhesion by Streptococcus mutans, and were susceptible to pigmentation and brushing cycles; immersion in coffee and simulated brushing changed color, but not translucency for all materials; thermocycling reduced surface hardness of the enamel adjacent to all restorations in this study; and that cariogenic challenge also reduced enamel hardness, except for the EQ group, which maintained its hardness, showing its potential to influence enamel resistance demineralization.


Assuntos
Humanos , Streptococcus mutans , Remineralização Dentária , Materiais Biocompatíveis , Cárie Dentária , Resinas Sintéticas , Pigmentação , Análise de Variância , Cor
8.
Rev. Odontol. Araçatuba (Impr.) ; 41(2): 52-57, maio-ago.2020. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1102702

RESUMO

Objetivo: avaliar a adesão bacteriana do Streptococcus mutans na superfície de uma resina composta do tipo incremento único submetida a diferentes protocolos de polimento. Materiais e métodos: foram realizadas 60 amostras nas quais foram divididas aleatoriamente em 6 grupos (n=10) de diferentes tratamentos de superfície. Cinco amostras de cada grupo foram separadas e submetidas ao estudo de adesão bacteriana, das quais duas foram analisadas pela microscopia eletrônica de varredura. Foram contabilizadas as unidades formadoras de colônias UFC/ml de modo manual e realizada a média e desvio padrão de cada grupo. De acordo com os resultados analisados através do teste de One Way ANOVA e comparações múltiplas de Tukey observou-se uma diferença estatisticamente significativa entre os grupos. Resultados: os valores de UFC/ mL variaram de 0 para o grupo American Burrs a 8,64 para o grupo Dhpro. Os grupos Jota e Dhpro não diferiram estatisticamente entre si (p=0,71), porém diferiram dos demais grupos avaliados (p=0,45). Os grupos American Burrs e o controle negativo não diferiram estatisticamente entre si (p>0.999) e diferiram dos demais grupos testados (p=0,20). O grupo de controle positivo diferiu estatisticamente dos outros grupos (p=0,02) assim como o grupo KG (p=0,01). Conclusão: Diante dos resultados obtidos, pode-se concluir que, a superfície da resina Bulk Fill One submetida a diferentes protocolos de polimento e mesmo sem ter passado por nenhum tratamento de superfície é passível de adesão bacteriana seja por contagem manual ou microscopia eletrônica de varredura(AU)


Objective: To evaluate the bacterial adhesion of Streptococcus mutans on the surface of a single increment composite resin submitted to different polishing protocols. Materials and methods: 60 samples were randomly divided into 6 groups (n = 10) of different surface treatments. Five samples from each group were separated and submitted to the bacterial adhesion study, two of which were analyzed by scanning electron microscopy. The UFC/ml colony forming units were accounted for manually and the mean and standard deviation of each group were performed. According to the results analyzed by the One Way ANOVA test and Tukey's multiple comparisons, a statistically significant difference was observed between the groups. Results: The values ranged from 0 for the American Burrs group to 8.64 for the Dhpro group. The Jota and Dhpro groups did not differ statistically (p = 0.71), but differed from the other groups evaluated (p = 0.45). The American Burrs and negative control groups did not differ statistically (p> 0.999) and differed from the other groups tested (p = 0.20). The positive control group differed statistically from the other groups (p = 0.02) as did the KG group (p = 0.01). Conclusion: It can be concluded that the surface of the Bulk Fill One resin submitted to different polishing protocols and even without any surface treatment is susceptible to bacterial adhesion either by manual counting or scanning electron microscopy(AU)


Assuntos
Streptococcus mutans , Aderência Bacteriana , Resinas Compostas , Resinas Sintéticas , Microscopia Eletrônica de Varredura
9.
Dental press j. orthod. (Impr.) ; 25(1): 26-27, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1089826

RESUMO

ABSTRACT Objective: To qualitatively and quantitatively assess the color changes effect and the color stability of the resin infiltrant on white spot lesions (WSLs), in comparison with nano-hydroxyapatite (nano-HA) toothpaste and microabrasion. Methods: WSLs were artificially created on sixty human premolars enamel surfaces and randomly assigned to equal four groups (n = 15 each): nano-HA toothpaste, microabrasion (Opalusture), resin infiltrant (Icon) treatment, or artificial saliva (control group). The color change (ΔE) of each specimen was measured by dental spectrophotometer (Vita Easyshade) at different time points: baseline, after WSLs' creation, after application of treatments, one month, three and six months after treatments application. Results: The ΔE value did not differ significantly for the four groups at baseline measurement before treatment (p> 0.05). Icon resin infiltrant improved the color of WSLs significantly immediately after its application, giving the lowest ΔE value (3.00 ± 0.59), when compared to other treatments (p< 0.001). There were no significant changes in ΔE (p> 0.05) for all groups during the follow up intervals (one month, three and six months after treatments application). Conclusion: Resin infiltrant can improve the color of WSLs and restore the natural appearance of enamel better than nano-HA toothpaste and microabrasion.


RESUMO Objetivo: avaliar qualitativamente e quantitativamente os efeitos nas mudanças e estabilidade da cor de lesões de mancha branca (LMBs), após tratamento com infiltração de resina, em comparação aos tratamentos com pasta de dentes com nanopartículas de hidroxiapatita (Nano-HA) e com microabrasão. Métodos: As LMBs foram criadas artificialmente em 60 superfícies de esmalte dentário de pré-molares humanos e aleatoriamente divididas em quatro grupos (n=15, cada): pasta de dentes Nano-HA, microabrasão (Opalusture), tratamento com infiltração de resina (Icon) e saliva artificial (grupo controle). A mudança de cor (ΔE) de cada espécime foi aferida com um espectrofotômetro odontológico (Vita Easyshade) em diferentes tempos: início do estudo, após a criação das LMBs, após a aplicação dos tratamentos, um mês, três meses e seis meses após a aplicação dos tratamentos. Resultados: Os valores de ΔE não diferiram significativamente entre os quatro grupos ao início do estudo (p > 0,05). A infiltração com resina Icon melhorou significativamente a coloração das LMBs imediatamente após a sua aplicação, com o menor valor de ΔE (3,00 ± 0,59), quando comparada às outras modalidades de tratamento (p < 0,001). Não houve mudanças significativas nos valores de ΔE (p > 0,05) em qualquer um dos grupos durante os intervalos de acompanhamento (um mês, três meses e seis meses após a aplicação do tratamento). Conclusão: A infiltração de resina é capaz de melhorar a coloração das LMBs e restaurar a aparência natural do esmalte de forma superior à pasta de dentes com Nano-HA e à microabrasão.


Assuntos
Humanos , Cárie Dentária , Resinas Sintéticas , Espectrofotometria , Cor , Esmalte Dentário
10.
Arq. odontol ; 56: 1-7, jan.-dez. 2020. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1120471

RESUMO

Objetivo: Avaliar a alteração da rugosidade superficial de uma resina composta nanoparticulada (Filtek Z350 XT ® ) após o uso de produtos clareadores de autoaplicação contento baixa concentração de peróxido de hidrogênio. Métodos: Para isto, foram confeccionados 30 corpos de prova deste material, divididos aleatoriamente em 3 grupos com 10 amostras cada, da seguinte forma: G1 (grupo controle) no qual as amostras não foram submetidas à ação de nenhum produto clareador; G2, realização de procedimento clareador com peróxido de hidrogênio a 10% (Crest 3D White Professional Effects Whitestrips ® ) em 2 aplicações de 30 minutos, por 10 dias consecutivos; e G3, tratamento com peróxido de hidrogênio a 7,7% (pincel Pretty Smile ® ) com o mesmo número de aplicações, tempo e dias do G2. Após este período cada corpo de prova foi analisado no rugosímetro Surftest SJ-301, para determinar a sua rugosidade superficial média. Estes dados foram então submetidos à análise estatística por meio da análise de variância (ANOVA) e teste de Tukey, nível de significância de 5% para comparações múltiplas. Resultados: Ao final do experimento, houve diferenças estatísticas significantes entre o grupo controle (G1) e os demais grupos (G2 e G3), com p < 0,05. Porém, quando analisados apenas os grupos submetidos ao clareamento com o peróxido de hidrogênio em diferentes concentrações (G2 e G3), não foi encontrada diferença significativa (p > 0,05). Conclusão: Após 10 dias, os produtos clareadores testados determinaram aumento significativo nos valores de rugosidade superficial média da resina composta nanoparticulada.


Aim: Tod evaluate the change in surface roughness of a nanoparticulate composite resin (Filtek Z350 XT ® ) after using over-the-counter bleaching products, containing a low concentration of hydrogen peroxide. Methods: For this, 30 specimens of this material were made, randomly divided into 3 groups with 10 samples each, as follows: G1 (control group) in which the samples were not subjected to the action of any bleaching product; G2, performing a bleaching procedure with 10% hydrogen peroxide (Crest 3D White Professional Effects Whitestrips ® ), in 2 applications of 30 minutes, for 10 consecutive days; and G3, treatment with 7.7% hydrogen peroxide (Pretty Smile ® ), with the same number of applications, time, and days as G2. After this period, each specimen was analyzed, using the Surftest SJ-301, to determine its average surface roughness. These data were then subjected to statistical analysis through analysis of variance (ANOVA) and Tukey's Test, with a significance level of 5% for multiple comparisons. Results: Statistically significant differences were found between the control group (G1) and the other groups (G2 and G3), with p < 0.05. However, when analyzing only the groups submitted to bleaching agents with hydrogen peroxide in different concentrations (G2 and G3), no significant difference was found (p > 0.05). Conclusions: After 10 days, the bleaching products tested in this study determined a significant increase in the average surface roughness values of the nanoparticulate composite resin.


Assuntos
Clareamento Dental , Resinas Compostas/análise , Clareadores , Clareadores Dentários/uso terapêutico , Peróxido de Hidrogênio/uso terapêutico , Resinas Sintéticas , Técnicas In Vitro , Materiais Dentários
11.
Braz. dent. sci ; 23(3): 1-6, 2020. ilus, tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1104370

RESUMO

Objective: was to evaluate the retentive force, fatigue resistance and deformity of clasps made from two materials cobalt chromium and poly ether ether ketone (PEEK). Material and Methods: sixteen models were fabricated,each one having lower 1st molar. Models were divided into two groups according to materials,group I (GI) for cobalt chromium (Co-Cr) and group II (GII) for PEEK. Each testing models and its clasps were mounted inside universal testing machine, the retention was measured by applying withdrawal force to it by this machine at 5 mm/min. The Fatigue resistance is measured by the reduction in retention through repeated insertion and removal cycles using robota chewing simulator. Removal and insertion cycling of clasps was carried out for 360, 730, 1080, 1,440, 2,116 and 2,880 cycles (corresponding to 3, 6, 9, 12, 18 and 24 months of simulated clinical use of a RPD) to simulate the fatigue resistance test. Deformity was measured before and after each cycling using a digital micrometer. Statistical analysis was done by 2-way-ANOVA test to detect significance effects of each variable. Results: Retention and fatigue resistance, after 360, 730, 1080, 1,440, 2,116 and 2,880 cycles totally the difference between Co-Cr and PEEK groups was statistically non-significant (P = 0.0980> 0.05) where (Co-Cr > PEEK). Deformation results, regardless to evaluation time, Co-Cr group recorded statistically significant higher deformation mean value than PEEK group (P = 0.008 < 0.05).Regardless to material group, deformation mean value changed nonsignificantly by time (P = 0.2882> 0.05). Conclusion: PEEK clasps (1.0 mm in cross section diameter) engage 0.50 mm undercut provide sufficient retention nearly similar that of Co-Cr clasps.(AU)


Objetivo: o objetivo foi avaliar a força de retenção, a resistência à fadiga e a deformidade dos grampos fabricados com dois materiais diferentes: cromo-cobalto (Co-Cr) e poliéter-éter-étercetona (PEEK). Materiais e métodos: dezesseis modelos foram confeccionados, cada um com 1º molar inferior. Os modelos foram divididos em dois grupos de acordo com o material: grupo I Co-Cr e grupo II para PEEK. Cada modelo de teste universal e seus grampos foram montados em uma máquina de teste universal. A retenção foi medida aplicando força de retirada por esta máquina a 5 mm/min. A resistência à fadiga foi medida pela redução na retenção através de ciclos repetidos de inserção e remoção usando um simulador do ciclo de mastigação. O ciclo de remoção e inserção dos grampos foi realizado por 360, 730, 1080, 1.440, 2.116 e 2.880 ciclos (correspondendo a 3, 6, 9, 12, 18 e 24 meses de uso clínico simulado de um RPD) para simular o teste de resistência à fadiga. A deformidade foi medida antes e após cada ciclo, usando um micrômetro digital. A análise estatística foi realizada pelo teste ANOVA de 2 fatores para detectar os efeitos de significância de cada variável. Resultados: A retenção e a resistência à fadiga após 360, 730, 1080, 1.440, 2.116 e 2.880 ciclos entre os grupos Co-Cr e PEEK não mostrou diferença estatisticamente significativa (p = 0,0980> 0,05), onde (Co-Cr> PEEK). Para os resultados da deformação, independentemente do tempo de avaliação, o grupo Co-Cr registrou um valor médio de deformação maior, com diferença estatística significativa, quando comparado com o grupo PEEK (p= 0,008 < 0,05). Independentemente do grupo de material, o valor médio da deformação foi alterado de forma não significativa pelo tempo (p= 0,2882> 0,05). Conclusão: os grampos PEEK (1,0 mm de diâmetro da seção transversal) engatam 0,50 mm retenção quase semelhante à dos grampos Co-Cr (AU)


Assuntos
Resinas Sintéticas , Ligas de Cromo , Prótese Parcial
12.
Araçatuba; s.n; 2020. 43 p. graf, ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1396449

RESUMO

A remoção de facetas de resina composta quando o retratamento se faz necessário representa um desafio ao clínico no sentido de preservação do remanescente dental. Sendo assim, o objetivo deste estudo foi avaliar dispositivos auxiliares na precisão dos retratamentos de facetas diretas, por meio de escaneamento digital. Setenta e cinco espécimes de dente bovino (10 x 8 mm ­ cor A1) foram selecionados, e então foi realizado o escaneamento inicial (T0). Em seguida, os espécimes foram preparados para faceta de resina composta e novamente escaneados (T1) para verificação da padronização dos preparos. As superfícies dentárias foram então restauradas com sistema adesivo e resina composta. Os espécimes foram divididos em 5 grupos (n=15): remoção sem dispositivo auxiliar (CN ­ grupo controle), remoção com alta rotação com LED branco (AL), remoção com alta rotação com luz ultra-violeta (UV), remoção com motor elétrico e multiplicadora 1/5 (MT) e remoção com uso de lupa de aumento 2,5x (MN). A remoção das facetas e o re-preparo dos espécimes foi feito por outro operador, sendo então realizado um novo escaneamento (T2). A alteração volumétrica entre T2 e T1, assim como, as áreas de desgaste dentário e/ou presença de resíduos de resina composta foram avaliados. A média entre desgaste e presença de resíduos entre T2 e T1 foi também realizada. Os dados foram submetidos aos testes estatísticos de Kruskal-Wallis e pós teste de Dunn ao nível de significância de 5%. Não foi encontrada diferença estatística entre os grupos entre T1 e T0, com uma média de desgaste de 0,28 mm (± 0,07), p ≥ 0.05. Somente houve diferença entre os grupos para as análises referentes às áreas de desgaste e de presença de resíduos (p ≤ 0,05). Ocorreu maiores áreas de desgaste para o grupo MN, sendo estatisticamente superior aos grupos CN e MT (p≤ 0,05). O oposto ocorreu para áreas de resíduos, sendo que o grupo MN apresentou as menores áreas de resíduos, sendo estatisticamente inferior aos grupos CN e MT (p≤ 0,05). Considerando a média entre desgaste e resíduos, ocorreu um desgaste adicional após o re-preparo, indepedente do grupo (p≥ 0,05). Apesar do uso de lupa odontológica ser mais efetivo para remoção da resina composta durante o retratamento de faceta direta, este proporciona maior desgaste da estrutura dentária. A similaridade da fluorescência entre a resina composta e o substrato dentário minimizou os benefícios do dispositivo com luz UV(AU)


The removal of direct composite veneers when the retreatment is necessary represents a challenge to the clinician in the sense of dental preservation. Thus, the aim of this study was to evaluate auxiliary devices, in the precision of direct composite veneers retreatments, through digital scanning. Seventy-five bovine tooth specimens (10 x 8 mm - A1 shade) were selected and the initial scanning (T0) was performed. Then, the specimens were prepared for direct composite veneer and rescanned (T1) to verify the standardization of the preparations. The dental surfaces were then restored with adhesive system and composite resin. The specimens were divided into 5 groups (n=15): removal without auxiliary device (CN - control group), removal with a hand piece with a white LED (WL), removal with a hand piece with an UV light source (UV), removal with electric motor and multiplier 1/5 hand piece (MT); and removal with the use of a 2.5x dental loupe (MN). The removal of the restorations and the re-preparation of the specimens were done by another operator, and a new scanning (T2) was performed. The volumetric change between T2 and T1, as well as the areas of additional dental wear and presence of composite resin residues were evaluated. The mean considering additional wear and the presence of residues between T2 and T1 were also performed. The data were submitted to Kruskal-Wallis and Dunn's as post-test, at significance level of 5%. No statistical difference among the groups were found between T1 and T0 with a wear mean of 0.28 mm (±0.07), p≥ 0.05. There were only statistical differences between the groups for the analyses related to the areas of wear and presence of residues (p≤ 0.05). There were greater areas of wear for MN group, being statistically superior to CN and MT groups (p≤ 0.05). The opposite occurred for areas of presence of residues, with the MN group presenting smaller areas of residues, being statistically lower than the CN and MT groups (p≤ 0.05). Considering the average between wear and residues, additional wear occurred after re-preparation, regardless of the group (p≥ 0.05). Although the use of dental loupe is more effective for removal of composite resin during the retreatment of direct composite veneers, it provides greater wear of the dental structure. The fluorescence similarity between the composite resin and the dental substrate minimized the benefits of UV light device(AU)


Assuntos
Equipamentos Odontológicos de Alta Rotação , Retratamento , Instrumentos Odontológicos , Facetas Dentárias , Resinas Sintéticas , Raios Ultravioleta , Cor , Resinas Compostas , Cimentos Dentários , Esmalte Dentário , Dentina , Desgaste dos Dentes , Fluorescência
13.
Arq. odontol ; 56: 1-8, jan.-dez. 2020. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1087806

RESUMO

Objetivo:O objetivo do estudo foi verificar, in vitro, a alteração de cor da resina composta Beautiful-Bulk®, exposta aos líquidos pigmentantes. Métodos:Foram confeccionados 60 espécimes da resina (15,0 mm de diâmetro e 1,0 mm de espessura, n = 5) nas cores A2, B2 e C2. Os espécimes foram mantidos em uma sala escura por sete dias, em ambiente seco, a 37 °C e, em seguida, foram fotografados com aparelho celular iPhone 6S®. Os espécimes foram divididos aleatoriamente e submetidos a ciclos de imersão em quatro líquidos: água destilada (controle), suco de açaí, Coca-Cola® e molho de tomate. As imersões foram realizadas em sete e quatorze dias de forma cíclica, após a confecção dos espécimes, três vezes ao dia, durante 20 minutos. Ao fim de cada ciclo, novas fotografias foram realizadas. As imagens foram analisadas no programa Adobe Photoshop® e os dados convertidos em L*a*b através de um histograma. A variação de cor (∆E) foi analisada pela escala CIE-Lab. Resultados:A análise dos resultados (One-way ANOVA, Teste de Tukey, p < 0,05) demonstrou que o grupo controle produziu maior alteração de cor (p < 0,05) em sete e quatorze dias na cor A2. A cor B2, no ciclo de quatorze dias, apresentou maior alteração de cor (p < 0,05) para os espécimes imersos em molho de tomate sem diferença estatística (p > 0,05) do controle. Para a cor C2, os espécimes imersos em molho de tomate tiveram maior alteração de cor (p < 0,05) em sete dias. Conclusão:Conclui-se que todas as substâncias pigmentantes e a água destilada foram capazes de produzir grandes alterações de cor na resina Beautifil Bulk®. Existe uma interação significativa entre a cor da resina e agentes pigmentantes.


Aim: This study sought to verify, in vitro, the color change of the nanoparticle composite resin, Beautiful Bulk®, exposed directly to pigmented liquids. Methods: Sixty test specimens were made in a Metal matrix (15.0 mm X 1.0 mm) using composite resin (n = 5) in colors A2, B2, and C2. The specimens were photographed with a smartphone (iPhone 6S®) seven days after the preparation. The specimens were kept in the dark for seven days, dry, at 37°C. The specimens were then randomly divided and immersed in four liquids: distilled water (control), açaí juice, Coca-Cola®, and tomato sauce. The immersions were performed in seven and fourteen days cyclically, three times a day, for 20 minutes. At the end of each immersion cycle, new photographs were taken with the same smartphone. The images were analyzed in the Adobe Photoshop® program, and the data was converted to L* a* b* through a histogram. The color variation (∆E) was analyzed by the CIE-Lab scale. Results: Analysis of the results (Tukey's test, p < 0.05) showed that the control group produced a greater color change (p < 0.05) in seven and fourteen days in the A2 shade. The B2 shade, in fourteen days, showed a greater color change (p < 0.05) for the specimens immersed in tomato sauce with no statistical difference (p > 0.05) of the control. For the C2 shade, the specimens immersed in tomato sauce presented a greater color change (p < 0.05) at seven days. Conclusion: It could therefore be concluded that there is a significant interaction between the composite resin and pigment agents. All pigmented substances produced color changes in the composite resin.


Assuntos
Resinas Sintéticas , Pigmentação , Cor , Resinas Compostas , Materiais Dentários , Imersão
14.
Rev. Ciênc. Méd. Biol. (Impr.) ; 18(3): 397-401, dez 20, 2019. fig, tab
Artigo em Português | LILACS | ID: biblio-1359198

RESUMO

Objetivo: o objetivo do presente estudo foi comparar a influência de diferentes protocolos de polimento sobre a rugosidade superficial de uma resina composta nanoparticulada. Metodologia: foram confeccionados 30 corpos de prova (1,5 mm espessura e 6 mm diâmetro), divididos em 3 grupos (n=10), de acordo com o tipo de polimento realizado: 1. Grupo controle; 2. Borrachas abrasivas em 3 granulações (grossa, média, fina); 3 Borracha abrasiva de granulação única. Todos os grupos receberam acabamento com lixa d'água, simulando uma ponta diamantada fina, sendo que o grupo controle não recebeu o polimento com borracha, após esse acabamento. Após o polimento dos grupos 2 e 3, a rugosidade superficial de cada corpo de prova, dos três grupos, foi avaliada em 3 medidas, através de rugosímetro, sendo calculada a média aritmética dos 3 valores picos e vales. A análise estatística inferencial foi feita por meio da ANOVA a 1-critério e teste de Tukey, para comparações múltiplas, com nível de significância de 5%. Resultados: observaram-se maiores valores de rugosidade no grupo controle (3,31µm), seguido do polimento de 1 passo (1,53µm) e 3 passos (0,48µm). Conclusão: diante disso, observa-se alta rugosidade superficial no acabamento com pontas diamantadas, simulado pelo grupo controle, e sua redução após o polimento. Entretanto, apenas o sistema de 3 passos foi capaz de produzir uma lisura superficial clinicamente aceitável.


Aim: the aim of the present study was to compare the influence of different polishing protocols on the surface roughness of a nanoparticulate composite resin. Methodology: Thirty specimens (1.5 mm thickness and 6 mm diameter) were made and divided into 3 groups (n = 10), according to the type of polishing performed: 1. Control group; 2. 3 grit abrasive rubs (thick, medium, thin); 3 Single grain abrasive rubber. All groups were finished with sandpaper, simulating a fine diamond tip, and the control group did not receive rubber polishing after this finish. After groups 2 and 3 polishing, the surface roughness of each specimen of the three groups were evaluated in 3 measurements by means of roughness, and the arithmetic mean of the 3 peaks and valleys (Ra) values were calculated. Inferential statistical analysis was performed using one-way ANOVA and Tukey test for multiple comparisons, with a significance level of 5%. Results: higher roughness values were observed in the control group (3.31µm), followed by 1-step (1.53µm) and 3-step (0.48µm) polishing. Conclusion: therefore, it is noticed a high surface roughness in the diamond-tipped finish, simulated by the control group, which was reduced after polishing. However, only the 3-step system was able to produce a clinically acceptable surface smoothness.


Assuntos
Humanos , Resinas Sintéticas , Resinas Compostas , Polimento Dentário , Nanopartículas
15.
Int. j. morphol ; 37(4): 1557-1563, Dec. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1040169

RESUMO

La plastinación es una técnica anatómica de conservación cadavérica creada en 1977 por Gunther von Hagens, en Heidelberg, Alemania, y que sustituye los líquidos biológicos y/o de fijación por acetona, para luego impregar las muestras con distintas resinas, dependiendo de la técnica de plastinación desarrollada, para finalmente llevar a cabo la polimerización de los componentes incorporados a las muestras, para obtener muestras biológicas secas y totalmente duraderas. El objetivo de este trabajo consistió en desarrollar un protocolo de plastinación de cortes con resina poliéster (Biodur® P40) en secciones de 3 mm de espesor de cerebro humano. La muestras fueron fijadas y conservadas con formalina al 10 %. Los cerebros luego fueron seccionados con una maquina cortadora de tejidos, obteniéndose láminas delgadas de 3 mm de espesor. Inmediatamente los cortes de cerebro fueron colocados en deshidratación en acetona al 100 %, a -25 ºC, durante 7 días el primer baño de acetona, y durante otros 3 días más, para el segundo baño de acetona. Una vez deshidratados los cortes, estos fueron colocados en resina poliéster Biodur® P40 y se llevó a cabo la impregnación forzada de los cortes, en cámara de vacío a temperatura ambiente (20 ºC). Una vez finalizada la impregnación forzada, se procedió a la etapa de curado, la cual en primer lugar consiste en el armado de las cámaras de curado dentro de las cuales se colocaran los cortes con resina poliéster. Las cámaras de curado fueron colocadas bajo luz UV para acelerar la polimerización del poliéster y finalizar el proceso de plastinación. Se logró desarrollar satisfactoriamente en el Laboratorio de Plastinación y Técnicas Anatómicas de la Universidad de La Frontera un protocolo de plastinación de cortes con resina poliéster, obteniendo una excelente conservación de cortes de cerebro, con diferenciación de sustancias gris y blanca, y conservación de todas las características morfológicas.


Plastination is an anatomical technique of cadaveric conservation created in 1977 by Gunther von Hagens, in Heidelberg, Germany, and that substitutes biological and / or fixation fluids with acetone, to then impregnate the samples with different resins, depending on the developed plastination technique, to finally carry out the polymerization of the components incorporated into the samples, to obtain dry and totally durable biological samples. The aim of this work was to develop a sheet plastination protocol with polyester resin (Biodur® P40) in 3 mm thick slices of human brain. The samples were fixed and preserved with 10 % formalin. The brains were sectioned with a slice cut machine, obtaining thin sheets of 3 mm thick. Immediately the slices of brain were placed in dehydration in 100 % acetone, at -25 °C, for 7 days the first acetone bath, and for another 3 more days, for the second acetone bath. Once the cuts were dehydrated, they were placed in Biodur® P40 polyester resin and the forced impregnation was carried out in a vacuum chamber at room temperature (20 °C). Once the forced impregnation was finished, the curing stage was carried out, which first consists in the assembly of the curing chambers within which the slices with polyester resin were placed. The curing chambers were placed under UV light to accelerate the polymerization of the polyester and finished the plastination process. A sheet plastination protocol with polyester resin was successfully developed in the Laboratory of Plastination and Anatomical Techniques of Universidad de La Frontera, obtaining excellent conservation of brain slices, with differentiation of gray and white substances, and conservation of all morphological characteristics.


Assuntos
Humanos , Poliésteres/química , Resinas Sintéticas/química , Encéfalo/anatomia & histologia , Plastinação/métodos , Protocolos Clínicos
16.
J. oral res. (Impresa) ; 8(supl.1): 7-10, ago. 9, 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1141327

RESUMO

Objectives: Compare tensile and transverse strength of new copolymers for denture base. Materials and methods: The specimens were prepared from heat cured acrylic resin with three types of additives: Acryester B, Ethoxycarbonylethylene, and Propenoic acid at a percentage of 5% and 10%. The tensile and transverse strains were tested, recorded and compared. Results: The analysis of variance display statistically significant difference. The p-value was 0.001 for each of tensile and transverse strain tests. Conclusions: The tensile strength of the novel copolymers increased. The transverse strength of some of the novel copolymers increased.


Assuntos
Humanos , Resinas Sintéticas/química , Resistência à Tração , Bases de Dentadura , Polimetil Metacrilato
17.
J. oral res. (Impresa) ; 8(supl.1): 19-23, ago. 9, 2019. ilus
Artigo em Inglês | LILACS | ID: biblio-1141501

RESUMO

Objectives: The aim of this study was to evaluate chemical and topographical changes in the intaglio zirconia surface induced by chemical conditioning solutions using FTIR and SEM analysis. Material and method: twelve plates for each FTIR and SEM tests from each zirconia materials (UPCERA HT White, BruxZir® Solid Zirconia, and Copran® Multilayer), milled by a Yenadent CAD/CAM system, sintered and divided randomly into a three groups. A different surface conditioning was applied to the intaglio surface of each group: 30% hydrogen peroxide, 30% citric acid and control group. Result and discussion: by using of the FTIR spectroscopy, an evidence of new bands formation appeared at 1637cm-1 and 3352cm-1 due to the high oxidizing effect of hydrogen peroxide, and at 630cm-1 and 1663cm-1 due to the chelating action of citric acid, and simultaneously, SEM assessment of the surface topography took place, to identify lines, scratches, or surface dissociation that appeared on the intaglio zirconia surface after conditioning. Conclusion: such analysis provides an enhancement of new convenient, less expensive, reliable trials to improve micro-bond strength of luting cement to Y-TZP ceramics.


Assuntos
Humanos , Resinas Sintéticas , Zircônio/análise , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Microscopia Eletrônica de Varredura , Cimentos Dentários , Peróxido de Hidrogênio
18.
J. oral res. (Impresa) ; 8(supl.1): 24-27, ago. 9, 2019. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1141502

RESUMO

This study assessed the effect of copolymerization on the microbiota of the oral cavity. The plant extraction was converted into aromatic derivatives, which were added to methyl methacrylate monomer. Fourier transform infrared spectroscopy spectra showed no negative effects of these additives on the polymerization process. All the assayed derivatives displayed some degree of antibacterial activity.


Assuntos
Humanos , Eugenol/análise , Bases de Dentadura , Microbiota , Resinas Sintéticas , Espectroscopia de Infravermelho com Transformada de Fourier , Polimerização , Anti-Infecciosos/isolamento & purificação
19.
Rev. cient. Esc. Univ. Cienc. Salud ; 6(1): 29-35, ene.-jun. 2019. ilus
Artigo em Espanhol | LILACS | ID: biblio-1023735

RESUMO

La técnica de resina inyectada es un trata-miento estético con el que es posible prede-cir el resultado final y trasladar del encerado diagnóstico la forma anatómica deseada a una restauración sobre la superficie dental, prediciendo el aspecto estético para esco-ger el color y la textura del material restaura-dor; estableciendo parámetros oclusales como modificar la posición y alineación de dientes, contorno fisiológico, perfil labial, posición del borde incisal y orientación gingi-val. Además, esta técnica puede realizarse con o sin preparación de la superficie, ase-gura una adaptación uniforme del material de restauración y aumenta el potencial para diseñar preparaciones más conservadoras, pues conservar tejido dental y predecir el resultado final son objetivos de esta técnica. El presente reporte de caso es sobre la rehabilitación estética y funcional con cari-llas dentales de resina inyectada en pacien-te femenina de 19 años que se presentó a la clínica dental de la Subdirección de Desa-rrollo Estudiantil, Cultural, Arte y Deporte (SUDECAD), de la Universidad Nacional Autonóma de Honduras en el Valle de Sula (UNAH-VS), con 4 dientes afectados que presentaban dolor, grietas a nivel del esmal-te, pigmentaciones oscuras, restos de restauraciones previas con pobre anatomía y mal adaptadas; como resultado, una sonri-sa poco favorecedora. En este caso se presenta una opción de tratamiento funcio-nal y estético con el que se le dió solución rápida y predecible. Tratamiento que forma parte de la continua búsqueda para brindar una sonrisa estética y saludable que todo profesional de la Odontología debe ofrecer...(AU)


Assuntos
Humanos , Feminino , Adulto , Resinas Sintéticas , Técnicas de Movimentação Dentária , Facetas Dentárias , Reparação de Restauração Dentária
20.
Int. j. med. surg. sci. (Print) ; 6(1): 26-30, mar. 2019.
Artigo em Inglês | LILACS | ID: biblio-1254188

RESUMO

The availability of new scientific information about the etiology, diagnosis and treatment of carious lesions and the introduction of reliable adhesive restorative materials substantially reduced the need of extensive tooth preparations. In order to achieve a successful procedure, an adequate bonding interface between old and new composite is required. The aim of this article is to review the concepts and techniques described in the literature for the improvement of resin-resin bonding. Bonding to dentin has been quite difficult to achieve. The difficulties are that dentin's histological structure and chemical composition are very different from those of the enamel. Bonding to dentin requires, besides acid conditioning and the adhesive required for enamel, a primer or dentin bonding agent, which is a hydrophilic, able to penetrate by infiltrating the microscopic spaces of the collagen mesh. The repairing of faulty restorations is a treatment option that has proven to be quite effective and safe, since it presents excellent results over time. For this purpose, different methods for surface treatment have been develo-ped, which has a great effect on the resistance of the reparation bonding. In order to achieve successful bonding between both resins, the following steps are recommended, including: surface roughening, acid etching, silane application, and bonding agent application


Assuntos
Humanos , Colagem Dentária/métodos , Resinas Sintéticas , Resinas Compostas , Cimentos de Resina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...