Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 192
Filtrar
1.
Rev. bras. ginecol. obstet ; 45(2): 96-103, Feb. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449706

RESUMO

Abstract This comprehensive review compares clinical protocols of important entities regarding the management of fetal growth restriction (FGR), published since 2015. Five protocols were chosen for data extraction. There were no relevant differences regarding the diagnosis and classification of FGR between the protocols. In general, all protocols suggest that the assessment of fetal vitality must be performed in a multimodally, associating biophysical parameters (such as cardiotocography and fetal biophysical profile) with the Doppler velocimetry parameters of the umbilical artery, middle cerebral artery, and ductus venosus. All protocols reinforce that the more severe the fetal condition, the more frequent this assessment should be made. The timely gestational age and mode of delivery to terminate the pregnancy in these cases can vary much between the protocols. Therefore, this paper presents, in a didactic way, the particularities of different protocols for monitoring FGR, in order to help obstetricians to better manage the cases.


Resumo Esta revisão compreensiva compara protocolos clínicos de entidades importantes em relação ao manejo da restrição de crescimento fetal (RCF), publicados desde 2015. Cinco protocolos foram escolhidos para a extração de dados. Não houve diferenças relevantes quanto ao diagnóstico e classificação da RCF entre os protocolos. Em geral, todos os protocolos sugerem que a avaliação da vitalidade fetal deve ser realizada de forma multimodal, associando parâmetros biofísicos (como cardiotocografia e perfil biofísico fetal) aos parâmetros dopplervelocimétricos da artéria umbilical, artéria cerebral média e ducto venoso. Todos os protocolos reforçam que quanto mais grave a condição fetal, mais frequente essa avaliação deve ser feita. A idade gestacional oportuna e o modo de parto para interromper a gravidez nesses casos podem variar muito entre os protocolos. Portanto, este trabalho apresenta, de forma didática, as particularidades de diferentes protocolos de acompanhamento de RCF, a fim de auxiliar os obstetras no melhor manejo dos casos.


Assuntos
Humanos , Recém-Nascido , Recém-Nascido Prematuro , Cardiotocografia , Fluxometria por Laser-Doppler , Guias como Assunto , Retardo do Crescimento Fetal
2.
Artigo em Inglês | LILACS | ID: biblio-1370080

RESUMO

Objective: it is well known that low omentin levels and reduced bioavailability of nitric oxide (NO) are outgrowth of obesity. Besides, in obese subjects, microvascular dysfunction can be an initial stage of cardiovascular diseases. This situation can be evaluated with skin laser­Doppler flowmetry (LDF). Methods: in this study we investigated the effects of 12 weeks moderate physical exercise on microvascular reactivity and plasma levels of omentin and NO in 25 overweight and obese subjects. Control group was composed of 28 sedentary participants who were neither obese nor overweight. Microvascular reactivity was handled by measurement of skin blood flow from the ring finger of the right hand with LDF, which is a non­invasive method for evaluation. With this method, it was aimed to examine the post­occlusive reactive hyperemia response of the patients. None of the participants in both groups have never followed a regular exercise schedule in their life span. Results: with regular exercise, there was a statistically significant decrease in glucose (p=0.008), cholesterol (p=0.05), and triglyceride (p=0.048) levels, while body mass index, high­density lipoprotein, and low­density lipoprotein levels did not change significantly in overweight/obese group. Also, the omentin level significantly increased (p=0.01), but NO level did not change significantly. Moreover, the amount of change in omentin and NO levels measured before and after the physical exercise were significantly correlated (r=0.57). Considering the microcirculation, rest flow (p=0.001) and peak flow value of LDF (p=0.001) increased after the physical exercise. Conclusion: our study shows that moderate physical exercise affects microvascular reactivity and plasma levels of omentin in overweight and obese subjects.


Objetivo: sabe-se que níveis baixos de omentina e a reduzida biodisponibilidade de óxido nítrico (NO) são consequências da obesidade. Além disso, a disfunção microvascular pode ser um estágio inicial de doenças cardiovasculares em indivíduos obesos. Essa situação pode ser avaliada com a fluxometria de pele laser-Doppler (LDF). Métodos: foram investigados os efeitos do exercício físico moderado por 12 semanas na reatividade microvascular e nos níveis plasmáticos de omentina e NO em 25 indivíduos com sobrepeso e obesidade. O grupo controle foi composto por 28 participantes sedentários que não eram obesos nem com sobrepeso. A reatividade microvascular foi obtida pela medida do fluxo sanguíneo da pele do dedo anelar da mão direita com LDF, que é um método não invasivo de avaliação. Com este método, objetivou-se examinar a resposta da hiperemia reativa pós-oclusiva dos pacientes. Os participantes de ambos os grupos nunca seguiram um cronograma regular de exercícios em sua vida. Resultados: com o exercício regular houve diminuição estatisticamente significativa dos níveis de glicose (p=0,008), de colesterol (p=0,05) e de triglicerídeos (p=0,048), enquanto o índice de massa corporal e os níveis de lipoproteínas de alta e baixa densidade não se alteraram significativamente no grupo com sobrepeso/obesidade. Além disso, o nível de omentina aumentou significativamente (p=0,01), mas o nível de NO não apresentou modificações significas. Observou-se, também, que as modificações nos níveis de omentina e NO mensurados antes e após o exercício físico foram significativamente correlacionados (r=0,57). Em relação à microcirculação, os valores do fluxo de repouso (p=0,001) e do valor de fluxo de pico e da LDF (p=0,001) aumentaram após o exercício físico. Conclusão: nosso estudo mostra que o exercício físico moderado afeta a reatividade microvascular e os níveis plasmáticos de omentina em indivíduos com sobrepeso e obesidade.


Assuntos
Humanos , Masculino , Feminino , Circulação Sanguínea , Doenças Cardiovasculares , Exercício Físico , Obesidade , Fluxometria por Laser-Doppler
3.
São Paulo; s.n; s.n; 2021. 60 p. tab, graf.
Tese em Inglês | LILACS | ID: biblio-1415547

RESUMO

Unprotected chronic exposure to ultraviolet radiation generates many harmful effects to human skin and UV filters are essential to health, however, traditional sunscreens do not provide enough protection against cutaneous oxidative stress, a process amplified by UV radiation. Therefore, is been proposed the development of multifunctional photoprotective formulations, acting in the absorption/reflection of UV radiation and assisting in cutaneous homeostasis. In the present study, ferulic acid is used in conjunction with two sunscreens, bemotrizinol and ethylhexyl triazone, for the determination of biosafety and efficacy methods, using techniques that better elucidate the effects of ferulic acid. Skin permeation assays were performed by applying a formulation containing the three substances in the stratum corneum of volunteers, which were removed by the tape stripping method (ex vivo) with follow quantification by high performance liquid chromatography (HPLC). The test was able to evaluate the penetration depth of the substances, characterizing them. In addition, the simultaneous quantification of the three substances was performed by a single and fast method, facilitating their analysis and improving the technique. Also, TBARS (thiobarbituric acid reactive substances) assays were performed in stratum corneum removed by tape stripping (ex vivo), evaluating the potential of cutaneous lipid peroxidation, with or without ferulic acid. To date, it is the first time that TBARS method is used to characterize the stratum corneum (ex vivo) and quantified by HPLC. The protocol developed may aid in the efficacy of antioxidant agents in studies aimed at elucidating the level of lipid peroxidation caused by drugs and cosmetics, and even in carrying out baseline studies characterizing different ethnicities and genders. As last, an anti-inflammatory in vivo assay with Laser Doppler flowmetry equipment was used to compare the sunscreen formulation with or without ferulic acid. Data indicated that the antioxidant reduced the angular coefficient of the perfusion units, mitigating the inflammatory effects. Furthermore, a significant difference was found between the genders, suggesting a more pronounced inflammatory reaction in women. Ferulic acid proved to be a valuable resource, besides being safe and raise the SPF of sunscreens, it also mitigates the effects of inflammation


A exposição crônica desprotegida à radiação ultravioleta (UV) contribui para o desenvolvimento de câncer de pele e os filtros solares são relevantes para evitar tais efeitos prejudiciais, porém, os protetores solares tradicionais não geram proteção suficiente contra o estresse oxidativo cutâneo. Logo, espera-se o desenvolvimento de formulações fotoprotetoras multifuncionais, atuando não somente na absorção e/ou reflexão da radiação UV, mas, também, auxiliando na homeostase cutânea, com presença de agentes antioxidantes. No presente estudo foi utilizado o ácido ferúlico conjuntamente com dois filtros solares, o bemotrizinol e a triazona de octila, para determinação de métodos de segurança e eficácia, utilizando técnicas que melhor elucidem e comprovem os efeitos do ácido ferúlico. Foram realizados ensaios de permeação cutânea pela aplicação tópica de formulação contendo as três substâncias em voluntários, sendo o estrato córneo retirado pelo método de tape stripping (ex vivo) com subsequente quantificação por cromatografia líquida de alta eficiência (CLAE). O ensaio pôde avaliar a profundidade de penetração das substâncias, caracterizando-as. Ademais, a quantificação simultânea das três substâncias foi efetuada por método único e rápido, facilitando análise com aprimoramento da técnica. Em adição, foi realizado ensaios de TBARS (substâncias reativas ao ácido tiobarbitúrico) em estrato córneo removido por tape stripping (ex vivo), para avaliar o potencial de peroxidação lipídica cutânea, contendo ou não o ácido ferúlico. Até o presente momento, é a primeira vez que o método TBARS é utilizado para caracterização do estrato córneo (ex vivo) e quantificada por CLAE. O protocolo desenvolvido pode auxiliar na eficácia de agentes antioxidantes, em estudos que visam elucidar o nível de peroxidação lipídica causada por medicamentos e cosméticos e, até mesmo, na realização de estudos de base, caracterizando etnias e gêneros. Ademais, um ensaio anti-inflamatório in vivo com equipamento de fluxometria Laser Doppler foi utilizado para comparar a formulação fotoprotetora com ou sem ácido ferúlico. Os dados indicaram que o antioxidante reduziu o coeficiente angular das unidades de perfusão, mitigando os efeitos inflamatórios. Ainda, foi identificada diferença entre os gêneros, sugerindo reação inflamatória mais pronunciada em mulheres. O ácido ferúlico provou ser um recurso valioso, além de ser seguro e elevar o FPS dos fotoprotetores, também atenuando os efeitos da inflamação


Assuntos
Protetores Solares/análise , Eficácia , Fatores de Proteção , Anti-Inflamatórios/análise , Antioxidantes/administração & dosagem , Radiação , Neoplasias Cutâneas/classificação , Raios Ultravioleta/efeitos adversos , Preparações Farmacêuticas/análise , Cromatografia Líquida de Alta Pressão/métodos , Substâncias Reativas com Ácido Tiobarbitúrico/farmacologia , Fluxometria por Laser-Doppler/métodos , Estresse Oxidativo/efeitos dos fármacos , Cosméticos/classificação , Diagnóstico
4.
J. oral res. (Impresa) ; 9(5): 392-399, oct. 31, 2020. graf, ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1179028

RESUMO

Background: Oral mucositis (OM) is an inflammation of the oral mucosa due to cancer therapy that compromises the patient's quality of life. Laser Doppler flowmetry (LDF) is a non-invasive method to monitor microvascular blood flow (BF) in real-time. Purpose: Develop a method to evaluate BF in the genian region cheek in patients undergoing chemotherapy by LDF and compare the degrees of OM and pain with evaluation of BF. Material and methods: Evaluation of OM was performed using the World Health Organization (WHO) and Oral Mucositis Assessment Scale (OMAS) scales and the visual analog scale for pain evaluation. For flowmetry analysis, a laser Doppler flowmeter (moorVMSTM™, 780 nm wavelength and VP3 probe), fixed by an acrylic resin support was used; VP3 probe was positioned on the genian region and the patient's head was stabilized with a neck pillow for an accurate measurement. The Wilcoxon test was used to compare the flowmetry results at the studied times. The Pearson correlation coefficient was used to evaluate relationships between BF and the WHO, OMAS and visual analog scales. Results: Eleven patients of both sexes, aged between 30 and 78 years, with OM were included. An increase in cutaneous BF was observed at the initial times of OM, with progressive reduction during the chemotherapy cycle. There was a statistical difference (p<0.05) between time point T0 (first consultation) and time point T6 (last consultation). Conclusion: The method developed in this pilot study is effective, reliable, and reproducible, and allows the evaluation of BF dynamics in the genian region using LDF of patients undergoing chemotherapy at risk of developing OM.


Antecedentes: La mucositis oral (MO) es una inflamación de la mucosa oral debido a la terapia del cáncer, que compromete la calidad de vida del paciente. La flujometría láser Doppler (FLD) es un método no invasivo para monitorear el flujo sanguíneo microvascular (FS) en tiempo real. Objetivo: Desarrollar un método para evaluar la FS en la mejilla de la región geniana en pacientes sometidos a quimioterapia por FLD y comparar los grados de MO y dolor con la evaluación del FS. Material y Métodos: La evaluación de la MO se realizó utilizando las escalas de la Organización Mundial de la Salud (OMS) y la Escala de Evaluación de la Mucositis Oral (OMAS) y la escala analógica visual para la evaluación del dolor. Para el análisis de flujometría se utilizó un flujómetro láser Doppler (moorVMSTM™, longitud de onda de 780 nm y sonda VP3), fijado por un soporte de resina acrílica; La sonda VP3 se colocó en la región geniana y la cabeza del paciente se estabilizó con una almohada para el cuello para una medición precisa. Se utilizó la prueba de Wilcoxon para comparar los resultados de la flujometría en los tiempos estudiados. Se utilizó el coeficiente de correlación de Pearson para evaluar las relaciones entre FS y las escalas de la OMS, OMAS y analógicas visuales. Resultados: Se incluyeron 11 pacientes de ambos sexos, con edades comprendidas entre 30 y 78 años, con MO. Se observó un aumento del FS cutáneo en los momentos iniciales de la MO, con reducción progresiva durante el ciclo de quimioterapia. Hubo una diferencia estadística (p<0.05) entre el momento T0 (primera consulta) y el momento T6 (última consulta). Conclusión: El método desarrollado en este estudio piloto es efectivo, confiable y reproducible, y permite evaluar la dinámica del FS en la región geniana utilizando FLD de pacientes sometidos a quimioterapia con riesgo de desarrollar MO.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Estomatite/etiologia , Fluxometria por Laser-Doppler , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Dor , Qualidade de Vida , Microcirculação , Antineoplásicos/efeitos adversos
5.
Rev. Fac. Cienc. Méd. Univ. Cuenca ; 38(2): 29-38, ago.2020. ^c21 cm.ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1178356

RESUMO

Introducción: la flujometría de la arteria pulmonar en fetos sanos puede ser un estudio predictor de la madurez pulmonar, lo que conlleva a un impacto en la disminución de la mortalidad perinatal.Objetivo: establecer el índice de tiempo de aceleración/tiempo de eyección de la arteria pulmonar (TA/TE) como un indicador de madurez pulmonar fetal en gestantes entre 26 y 40 semanas de gestación (SG), usuarias del Hospital Especializado Fundación Humanitaria Pablo Jaramillo Crespo, periodo 2017.Métodos: estudio de validación de prueba diagnóstica. Se evaluó la flujometría de la arteria pulmonar por ecografía doppler en 300 fetos sanos de gestantes entre 15 y 45 años de edad. Para la recolección de datos se utilizó encuestas y para la determinación de la validez se usó los estadísticos sensibilidad (S), especificidad (E), valor predictivo positivo (VPP) y valor predictivo negativo (VPN). Resultados: el valor del índice TA/TE de la arteria pulmonar fue 0.216 para las gestantes entre 26-28 SG; de 0.253 entre 29-31 SG; de 0.279 entre 32-34 SG; de 0.315 para las gestantes entre 35-37 SG y de 0.349 entre 38-40 SG. Las 37 SG en punto de corte fue de 0.320; el área ROC fue 0.98 con una S: 95.2%, E: 97.2%. VPP 93.0% y VPN 98.1%.Conclusiones: el índice TA/TE de la arteria pulmonar demostró correlación con la edad gestacional. Un índice TA/TE de 0.320, como punto de corte, predice madurez pulmonar fetal (AU);


Introduction: pulmonary artery flow metric in healthy fetuses can be a predictive study of lung maturity, which leads to an impact on the decrease in perinatal mortality.Objective: to establish the ratio of pulmonary artery acceleration time to ejection time (AT/ET) as an indicator of fetal lung maturity in pregnant women from 26 to 40 weeks of gestation (WG), users of the "Hospital Especializado Fundación Humanitaria Pablo Jaramillo Crespo", period 2017.Methods: A validity study of diagnostic tests was carried out. Pulmonary artery flow metric was evaluated by Doppler ultrasound in 300 healthy fetuses of pregnant women between 15 to 45 years old. Surveys were used to collect data. Sensitivity (S), specificity (E), positive predictive value (PPV) and negative predictive value (NPV) were used to determine validity.Results: the value of the TA / TE index of the pulmonary artery was 0.216 for pregnant women between 26-28 WG; of 0.253 between 29-31 WG; 0.279 between 32-34 WG; 0.315 for pregnant women between 35-37 WG and 0.349 between 38-40 WG. The 37 WG at the cut-off point was 0.320; the ROC area was 0.98 with a S: 95.2%, E: 97.2%. The PPV 93.0% and NPV 98.1%.Conclusions: the AT/ET ratio of pulmonary artery showed correlation with gestational age. An AT/ET ratio of 0.320, as a cut-off point, predicts fetal lung maturity (AU);


Assuntos
Humanos , Feminino , Gravidez , Adolescente , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Artéria Pulmonar/diagnóstico por imagem , Idade Gestacional , Ultrassonografia Doppler , Maturidade dos Órgãos Fetais , Pulmão/embriologia , Sensibilidade e Especificidade , Fluxometria por Laser-Doppler
7.
J. appl. oral sci ; 28: e20190145, 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1056576

RESUMO

Abstract Ultrasonic wave technology is widely used during dental treatments. We previously demonstrated that this method protects the gingival tissue. However, the physiological change on the gingival microvasculature caused by this method remains unclear. Objective The aim of this study was to investigate the relationship between the morphological and physiological effects on gingival microcirculation when preparing teeth, using the conventional dental turbine or ultrasonic method. Methodology The lower premolar teeth of beagle dogs were prepared along the gingival margin by using a dental turbine or ultrasonic wave instrument. Gingival vasculature changes were investigated using scanning electron microscopy for corrosion resin casts. Gingival blood flow at the preparation site was determined simultaneously by laser Doppler flowmetry. These assessments were performed immediately (Day 0), at 7 days and 30 days after tooth preparation. Results At day 0, in the turbine group, blood vessels were destroyed and some resin leaked. Furthermore, gingival blood flow at the site was significantly increased. In contrast, the ultrasonic group demonstrated nearly normal vasculature and gingival blood flow similar to the non-prepared group for 30 days after preparation. No significant alterations occurred in gingival circulation 30 days after either preparation; however, the turbine group revealed obvious morphological changes. Conclusions Based on multiple approach analyses, this study demonstrated that ultrasonic waves are useful for microvascular protection in tooth preparation. Compared with a dental turbine, ultrasonic wave instruments caused minimal damage to gingival microcirculation. Tooth preparation using ultrasonic wave instruments could be valuable for protecting periodontal tissue.


Assuntos
Humanos , Animais , Feminino , Cães , Preparo do Dente/instrumentação , Ondas Ultrassônicas , Gengiva/irrigação sanguínea , Microcirculação/fisiologia , Fatores de Tempo , Microscopia Eletrônica de Varredura , Protocolos Clínicos , Reprodutibilidade dos Testes , Fluxometria por Laser-Doppler/métodos , Preparo do Dente/métodos , Instrumentos Odontológicos
8.
Acta cir. bras ; 34(12): e201901203, 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1054686

RESUMO

Abstract Purpose Composite flaps used in reconstructive surgery may intra- and postoperatively suffer from hypoperfusion and/or ischemia-reperfusion influencing wound healing. We aimed to follow-up the effect of ischemia on adipocutaneous flaps' wound healing and microcirculation. Methods In anesthetized rats groin flaps were formed bilaterally. In Control group the flaps were repositioned and sutured back. In Ischemia-Reperfusion (I/R) group before repositioning and suturing the flap pedicles were clamped for 60 minutes. Laser Doppler (LD) fluxmetry and temperature probes were applied on the cranial, central and caudal flap regions before/after preparation and ischemia, re-suturing, and on the 1st-3rd-5th-7th-14th postoperative days, before the final examinations and biopsies for histology. Results Flaps' skin temperature quickly recovered after repositioning. LD values were lower in the I/R group, reaching a significant level by the 3rd postoperative day, and remained lowered till the 14th day. The magnitude of alterations differed in the flap regions. Histologically normal wound healing process was seen, except for some I/R flaps, where hypertrophized mammary glands were found. Conclusions Short-term ischemia could influence flap microcirculation and wound healing, and may result in hypertrophized mammary glands. Laser Doppler could be used to evaluate intra- and postoperative microcirculatory changes and may have significance in predicting complications.


Assuntos
Animais , Masculino , Ratos , Pele/irrigação sanguínea , Cicatrização/fisiologia , Traumatismo por Reperfusão/complicações , Procedimentos Cirúrgicos Dermatológicos/efeitos adversos , Retalho Miocutâneo/irrigação sanguínea , Microcirculação/fisiologia , Período Pós-Operatório , Valores de Referência , Pele/patologia , Fatores de Tempo , Biópsia , Temperatura Corporal , Traumatismo por Reperfusão/patologia , Reprodutibilidade dos Testes , Resultado do Tratamento , Fluxometria por Laser-Doppler , Modelos Animais de Doenças , Retalho Miocutâneo/patologia
9.
Rev. medica electron ; 40(6): 2030-2052, nov.-dic. 2018.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-978716

RESUMO

RESUMEN El bajo peso al nacer representa en la actualidad uno de los problemas prioritarios de salud a nivel mundial, que aumenta el riesgo de morbimortalidad. Cuba presenta cifras bajas de bajo peso al nacer lo que la ubica entre los cinco países con indicadores más bajos a nivel mundial, pero a pesar de ello, el bajo peso al nacer, específicamente la restricción del crecimiento intrauterino constituye un problema de salud por las complicaciones que produce, por lo que su predicción precoz es vital para evitar la muerte. Por tal motivo los autores proponen como objetivo exponer los referentes teóricos relacionados con el valor predictivo de la flujometría doppler en la restricción del crecimiento intrauterino, basándose en los fundamentos teóricos más actualizados. Se concluye que la flujometría doppler combinada de las arterias uterinas y umbilicales, tiene valor predictor en la restricción del crecimiento intrauterino y en su manejo y seguimiento (AU).


ABSTRACT Low weight at birth is currently one of the priority health problems around the world, increasing the morbi-mortality risk. Cuba shows little quantities of low weight at birth, locating the country among the five ones with the lowest indicators in the world; nevertheless, low weight at birth, specifically the intrauterine growth restriction arises as a health problem due to the complications it produces, making its precocious prediction vital to avoid death. The authors of this work have the objective of exposing theoretical referents related with the predictive value of the Doppler flowmetry in the restriction of the intrauterine growth on the bases of updated theoretical fundaments. They arrive to the conclusion that combined Doppler flowmetry of the uterine and umbilical arteries has a predictive value in the restriction of intrauterine growth and its management and follow up (AU).


Assuntos
Humanos , Feminino , Gravidez , Complicações na Gravidez , Recém-Nascido de Baixo Peso , Valor Preditivo dos Testes , Morbidade , Fluxometria por Laser-Doppler , Gravidez de Alto Risco , Retardo do Crescimento Fetal/prevenção & controle , Artérias Umbilicais , Mortalidade Infantil , Artéria Uterina , Retardo do Crescimento Fetal/diagnóstico
10.
Acta cir. bras ; 33(7): 597-608, July 2018. graf
Artigo em Inglês | LILACS | ID: biblio-949363

RESUMO

Abstract Purpose: To compare early- and late-effect remote ischemic preconditioning (RIPC) by analysing the microcirculatory, hemodynamic and histological changes in partial liver ischemia-reperfusion of rats. Methods: 60-minute partial liver ischemia followed by 120-minute reperfusion was performed without (Control group, n=7) or with preconditioning. In RIPC groups a tourniquet was applied around the left thigh using 3 cycles of 10-minute ischemia/10-minute reperfusion, one (RIPC-1, n=7) or twenty-four hours (RIPC-24, n=7) before I/R. Hemodynamic and microcirculatory measurements were performed before and after ischemia and in 30th, 60th and 120th minute of reperfusion and histological examination at the end of reperfusion. Results: Blood pressure decreased in all groups followed by biphasic changes in Control group. In RIPC groups R120 values returned almost to normal. Heart rate increased in Control and RIPC-1 groups at R120, while RIPC-24 did not show significant changes. Microcirculation of non-ischemic liver stayed constant in Control and showed significant changes in RIPC-24 group, while in ischemic liver elevated by R120 in all groups. RIPC didn't reduce histological alterations. Conclusion: Considering the survival and the results, both remote ischemic preconditioning protocols had beneficial effect in hepatic ischemia-reperfusion, however the histopathological findings were controversial.


Assuntos
Animais , Ratos , Traumatismo por Reperfusão/prevenção & controle , Precondicionamento Isquêmico/métodos , Isquemia/prevenção & controle , Fígado/irrigação sanguínea , Microcirculação/fisiologia , Temperatura , Fatores de Tempo , Pressão Sanguínea/fisiologia , Distribuição Aleatória , Reprodutibilidade dos Testes , Resultado do Tratamento , Fluxometria por Laser-Doppler , Modelos Animais de Doenças , Taxa Respiratória/fisiologia , Fígado/patologia
11.
Rev. cuba. med. gen. integr ; 34(2)abr.-jun. 2018. tab
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1093433

RESUMO

Introducción: La flujometría doppler constituye un método de control y evaluación para determinar la culminación de la gestación, permite entender de una mejor manera la dinámica fetoplacetaria lo que posibilita evitar todo riesgo que pueda dañar la maduración fetal, y a su vez la prematuridad, bajo peso al nacer y patologías de la preeclampsia. Objetivo: Determinar la utilidad de la flujometría doppler color, en el diagnóstico y manejo de la restricción de crecimiento intrauterino en embarazadas preeclámpticas. Métodos: Se realizó un estudio no experimental, transversal, de tipo descriptivo comparativo en el departamento de ecografía de la clínica Bolívar, Babahoyo - Ecuador durante el año 2013. Participaron 96 mujeres gestantes en edades entre 15 a 40 años, a las que se le realizó las intervenciones: Flujometría doppler, prueba de índice cerebro placentario, arteria cerebral media/arteria umbilical; para el análisis se emplearon los indicadores descriptivos entre las variables. Resultados: La prueba de índice cerebro placentario fue descompensada en el 53,1 por ciento de las mujeres, el volumen de líquido amniótico estuvo disminuido en el 46,9 por ciento, y la edad gestacional más vulnerable fue de las 32 a las 37 semanas de gestación. Conclusiones: La flujometría doppler con la prueba índice cerebro placentario es un indicador efectivo y seguro de bienestar fetal cuando esta prueba es normal, y un predictor de resultado adverso, así como un marcador de hipoxia fetal cuando está alterado, convirtiéndose en una herramienta útil para la decisión de interrumpir la gestación cuando la salud del feto está en peligro, o de mantener el embarazo cuando su comportamiento es normal(AU)


Assuntos
Humanos , Feminino , Gravidez , Fluxometria por Laser-Doppler/instrumentação , Pré-Eclâmpsia/diagnóstico , Epidemiologia Descritiva , Estudos Transversais
12.
Acta cir. bras ; 33(4): 296-305, Apr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-886282

RESUMO

Abstract Purpose: To evaluate the effect of the cilostazol on the evolution of partially avulsed flaps, using experimental model of cutaneous degloving in rat limbs. Methods: A controlled and randomized experimental study was carried out in which the blood flow and the percentage of flap necrosis were evaluated. We compared the study group, which received cilostazol, and the control group, which received enteral saline solution in the postoperative period. The blood flow in the flap was evaluated through Laser Doppler flowmetry, and a planimetry using the IMAGE J® software was employed for the calculation of the area of necrosis. Results: Enteral administration of cilostazol was associated with a higher mean blood flow in all regions of the flap, with a statistically significant difference in the proximal and middle regions (p<0.001) and a lower percentage of necrotic area in the flap (p<0.001). Conclusion: Postoperative enteral administration of cilostazol increased blood flow and decreased the total area of necrosis of avulsed cutaneous flaps of rat limbs.


Assuntos
Humanos , Animais , Masculino , Tetrazóis/uso terapêutico , Modelos Animais de Doenças , Inibidores da Fosfodiesterase 3/uso terapêutico , Desenluvamentos Cutâneos/tratamento farmacológico , Valores de Referência , Fluxo Sanguíneo Regional/efeitos dos fármacos , Retalhos Cirúrgicos , Tetrazóis/farmacologia , Fatores de Tempo , Distribuição Aleatória , Reprodutibilidade dos Testes , Resultado do Tratamento , Ratos Wistar , Fluxometria por Laser-Doppler , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/lesões , Extremidade Inferior/patologia , Inibidores da Fosfodiesterase 3/farmacologia , Desenluvamentos Cutâneos/cirurgia , Desenluvamentos Cutâneos/patologia , Necrose/tratamento farmacológico
13.
Rev. Col. Bras. Cir ; 45(4): e1837, 2018. tab, graf
Artigo em Português | LILACS | ID: biblio-956572

RESUMO

RESUMO Objetivo: avaliar, através de dopplerfluxometria, de venografia, de histologia e de evolução clínica, o uso de enxertos tubulares de biopolímero de cana-de-açúcar (BP) na reconstrução de veias femorais em cães. Métodos: oito cães adultos foram submetidos à reconstrução de veia femoral, à esquerda com enxerto tubular de BP e à direita com veia autóloga. No período pós-operatório, os animais foram submetidos à avaliação clínica e dopplerfluxometria das veias femorais. Após 360 dias, os cães foram reoperados e submetidos à flebografia das veias femorais com contraste iodado. Os segmentos das veias femorais contendo os enxertos foram retirados e enviados para avaliação histopatológica. Resultados: os cães não apresentaram hemorragia, hematoma, infecção da ferida operatória ou edema dos membros operados. Um animal apresentou dilatação venosa superficial na região inguinal esquerda. A flebografia realizada 360 dias após a primeira cirurgia demonstrou que três (37,5%) enxertos de BP e sete (87,5%) do grupo controle (C) estavam pérvios. Na avaliação histopatológica foi encontrada uma reação inflamatória com neutrófilos e linfócitos na superfície externa de ambos os grupos. Na camada íntima de revestimento dos enxertos e na camada externa nos dois grupos, foi encontrada fibrose. Conclusão: com base nos resultados obtidos com o modelo experimental utilizado, conclui-se que a BP apresenta potencial para ser utilizado como enxerto tubular para revascularização venosa, porém novas pesquisas precisam ser realizadas para confirmar a sua eficácia na revascularização de veias de médio e grande calibre, o que poderia permitir o seu uso na prática clínica.


ABSTRACT Objective: to evaluate, through Doppler flowmetry, venography, histology and clinical evolution, the use of sugarcane biopolymer (BP) tubular grafts in the reconstruction of femoral veins in dogs. Methods: we submitted eight adult dogs to femoral vein reconstruction, on the left with BP tubular graft and on the right with autologous vein. In the postoperative period, the animals underwent clinical evaluation and femoral vein Doppler flowmetry. After 360 days, we reoperated the dogs and submitted them to femoral vein phlebography with iodinated contrast. We removed the segments of the femoral veins containing the grafts and sent them for histopathological evaluation. Results: the dogs did not present hemorrhage, hematoma, surgical wound infection or operated limb edema. One animal had superficial venous dilatation in the left inguinal region. Phlebography performed 360 days after the first surgery showed that three (37.5%) BP grafts and seven (87.5%) grafts from the control group (C) were patent. In the histopathological evaluation, we found an inflammatory reaction, with neutrophils and lymphocytes on the external surface of both groups. In the intimal layer of the grafts and in the outer layer in the two groups, we observed fibrosis. Conclusion: based on the results obtained with the experimental model used, BP presents potential to be used as a tubular graft for venous revascularization. However, new research must be performed to confirm its efficacy in the revascularization of medium and large diameter veins, which could allow its use in clinical practice.


Assuntos
Animais , Masculino , Feminino , Cães , Bioprótese , Prótese Vascular , Implante de Prótese Vascular/métodos , Veia Femoral/transplante , Enxerto Vascular/métodos , Transplante Autólogo/métodos , Biopolímeros/uso terapêutico , Distribuição Aleatória , Fluxometria por Laser-Doppler , Implante de Prótese Vascular/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Modelos Animais , Saccharum , Veia Femoral/patologia
14.
Braz. j. med. biol. res ; 51(3): e6601, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889041

RESUMO

The primary aim of this study was to evaluate penile endothelial microvascular function in patients with primary arterial hypertension and age-matched normotensive subjects using laser speckle contrast imaging (LSCI). Additionally, we analyzed the acute penile microvascular effects induced by oral phosphodiesterase type 5 inhibitor (sildenafil; SIL) administration. Endothelium-dependent microvascular reactivity was evaluated in the penises and forearms of hypertensive patients (aged 58.8±6.6 years, n=34) and age-matched healthy volunteers (n=33) at rest and 60 min following oral SIL (100 mg) administration. LSCI was coupled with cutaneous acetylcholine (ACh) iontophoresis using increasing anodal currents. Basal penile cutaneous vascular conductance (CVC) values were not significantly different between control subjects and hypertensive individuals. Penile CVC values increased significantly after SIL administration in control (P<0.0001) and hypertensive (P<0.0001) subjects. Peak CVC values were not different between the two groups during penile ACh iontophoresis before SIL administration (P=0.2052). Peak CVC values were higher in control subjects than in hypertensive subjects after SIL administration (P=0.0427). Penile endothelium-dependent microvascular function is, to some extent, preserved in patients presenting with primary arterial hypertension under effective anti-hypertensive treatment. LSCI may be a valuable non-invasive tool for the evaluation of penile vascular responses to phosphodiesterase type 5 inhibitor.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Endotélio Vascular/fisiopatologia , Hipertensão/fisiopatologia , Pênis/irrigação sanguínea , Inibidores da Fosfodiesterase 5/administração & dosagem , Citrato de Sildenafila/administração & dosagem , Estudos de Casos e Controles , Voluntários Saudáveis , Fluxometria por Laser-Doppler/métodos , Microcirculação , Pênis/efeitos dos fármacos , Fluxo Sanguíneo Regional , Vasodilatação/efeitos dos fármacos
15.
Rev. bras. ginecol. obstet ; 39(9): 464-470, Sept. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-898900

RESUMO

Abstract Objective To describe the blood flow velocities and impedance indices changes in the uterine arteries of leiomyomatous uteri using Doppler sonography. Methods This was a prospective, case-control study conducted on 140 premenopausal women with sonographic diagnosis of uterine leiomyoma and 140 premenopausal controls without leiomyomas. Pelvic sonography was performed to diagnose and characterize the leiomyomas. The hemodynamics of the ascending branches of both main uterine arteries was assessed by Doppler interrogation. Statistical analysis was performed mainly using non-parametric tests. Results The median uterine volume of the subjects was 556 cm3, while that of the controls was 90.5 cm3 (p < 0.001). The mean peak systolic velocity (PSV), end-diastolic velocity (EDV), time-averaged maximum velocity (TAMX), time-averaged mean velocity (Tmean), acceleration time (AT), acceleration index (AI), diastolic/systolic ratio (DSR), diastolic average ratio (DAR), and inverse pulsatility index (PI) were significantly higher in the subjects (94.2 cm/s, 29.7 cm/s, 49.1 cm/s, 25.5 cm/s, 118 ms, 0.8, 0.3, 0.6, and 0.8 respectively) compared with the controls (54.2 cm/s, 7.7 cm/s, 20.0 cm/s, 10.0 cm/s, 92.0 ms, 0.6, 0.1, 0.4, and 0.4 respectively); p < 0.001 for all values. Conversely, the mean PI, resistivity index (RI), systolic/diastolic ratio (SDR) and impedance index (ImI) of the subjects (1.52, 0.70, 3.81, and 3.81 respectively) were significantly lower than those of the controls (2.38, 0.86, 7.23, and 7.24 respectively); p < 0.001 for all values. Conclusion There is a significantly increased perfusion of leiomyomatous uteri that is most likely due to uterine enlargement.


Resumo Objetivo Descrever as velocidades do fluxo sanguíneo e as alterações dos índices de impedância nas artérias uterinas leiomiomatoso utilizando a ultrassonografia Doppler. Métodos Estudo prospectivo, caso-controle, realizado em 140 mulheres pré-menopáusicas com diagnóstico ultrassonográfico de leiomioma uterino e em 140 controles na pré-menopausa sem leiomiomas. A ultrassonografia pélvica foi realizada para diagnosticar e caracterizar os leiomiomas. A hemodinâmica dos ramos ascendentes de ambas as artérias uterinas principais foi avaliada por meio de interrogatório Doppler. A análise estatística foi feita principalmente por meio de testes não paramétricos. Resultados A média do volume uterino dos das pacientes foi de 556 cm3, enquanto a dos controles foi de 90,5 cm3 (p < 0,001). A média de velocidade de pico sistólico (VPS), a velocidade diastólica final (VDF), a velocidade máxima do tempo médio (VMTM), a velocidade média do tempo médio (VMdTM), o tempo de aceleração (TA), o índice de aceleração (IA), a relação diástole/sístole (RDS), a proporção diastólica média (PDM) e o índice de pulsatilidade (IP) inversa foram significativamente maiores em pacientes (94,2 cm/s, 29,7 cm/s, 49,1 cm/s, 25,5 cm/s, 118 ms, 0,8, 0,3, 0,6 e 0,8, respectivamente) do que nos controles (54,2 cm/s, 7,7 cm/s, 20,0 cm/s, 10,0 cm/s, 92,0 ms, 0,6, 0,1, 0,4 e 0,4, respectivamente); p < 0,001 para todos os valores. Por outro lado, o IPmédio, o índice de resistividade (IR), a relação sístole/diástole (RSD) e o índice de impedância (II) nas pacientes (1,52, 0,70, 3,81 e 3,81, respectivamente) foram significativamente mais baixos do que os dos controles (2,38, 0,86, 7,23 e 7,24, respectivamente); p < 0,001 para todos os valores. Conclusão Existe um aumento significativo da perfusão dos úteros leiomiomatosos, que provavelmente se deve ao alargamento uterino.


Assuntos
Humanos , Feminino , Adulto , Neoplasias Uterinas/irrigação sanguínea , Neoplasias Uterinas/diagnóstico por imagem , Fluxometria por Laser-Doppler , Artéria Uterina/diagnóstico por imagem , Leiomioma/irrigação sanguínea , Leiomioma/diagnóstico por imagem , Estudos de Casos e Controles , Estudos Prospectivos , Ultrassonografia Doppler
16.
Rev. méd. Hosp. José Carrasco Arteaga ; 9(2): 195-198, Julio 2017. Cuadros
Artigo em Espanhol | LILACS | ID: biblio-1015813

RESUMO

INTRODUCCIÓN: La enfermedad hemolítica perinatal causada principalmente por la producción de anticuerpos irregulares anti D, es una enfermedad que por mucho tiempo fue de etiología y pronóstico desconocido, en la actualidad un manejo oportuno ha aumentado las expectativas de sobrevida. CASO CLÍNICO: Paciente femenino de 27 años de edad, multípara 1, embarazo de 27+1 semanas de gestación, RH negativo sensibilizada con Rogham después de postparto anterior, anemia fetal y diagnóstico reciente de diabetes gestacional. Los exámenes de laboratorio mostraron la velocidad máxima del flujo de la arteria cerebral media fuera de rangos normales, se hospitalizó para cordocentesis y transfusión intraútero. EVOLUCIÓN: Se realizó transfusión intrauterina, se evidenciaron parámetros normales, y se controló bisemanalmente. A las 29+1 semanas se realizó una segunda transfusión intrauterina, a las 33+4 semanas de gestación y durante control de rutina, se detectó por tercera vez aumento de la velocidad máxima del flujo de la arteria cerebral media, se interrumpió la gestación, se obtuvo recién nacido (RN) de sexo masculino, peso 2130 gramos, APGAR 6-8. CONCLUSIÓN: El uso de la velocidad máxima del flujo de la arteria cerebral media nos ayuda a realizar un diagnóstico certero no invasivo y un tratamiento oportuno de enfermedad hemolítica perinatal. Las transfusiones intrauterinas, lograron prolongar el embarazo por un periodo de 6 semanas, permitiendo un incremento de peso cercano a los mil gramos, desde el diagnóstico de nemia severa hasta su resolución.(au)


BACKGROUND: The Hemolytic Perinatal Disease is a disease unknown etiology and prognosis, actually a timely management has increased expectations of survival, is caused by the production of irregular antibodies anti D. CASE REPORT: 27-year-old female patient, multiparous 1, pregnancy of 27 + 1 weeks of gestation, RH negative sensitized with Rogham after postpartum, fetal anemia and recent diagnosis of gestational diabetes. Laboratory tests show maximum speed of the middle cerebral artery outside normal ranges, it was decided to hospitalize for cordocentesis and intrauterine transfusion. EVOLUTION: Intrauterine transfusion was performed, normal parameters were evident, and it was monitored biweekly. At 29 + 1 weeks, a second intrauterine transfusion was performed, at 33 + 4 weeks of gestation and during routine control, a third time increase of maximum speed of the middle cerebral artery was detected, gestation was interrupted, newborn male, weight 2130 grams, APGAR 6-8. CONCLUSION: The use of maximum speed of the middle cerebral artery helps us to make an accurate non-invasive diagnosis and timely treatment of the hemolytic perinatal disease. Intrauterine transfusions were able to prolong the pregnancy for a period of 6 weeks, allowing a weight increase of around one thousand grams, from the diagnosis of severe anemia to its resolution.(AU)


Assuntos
Humanos , Feminino , Gravidez , Isoimunização Rh/prevenção & controle , Fluxometria por Laser-Doppler , Assistência Perinatal , Transfusão de Sangue Intrauterina , Cordocentese
18.
Rev. ADM ; 73(5): 241-244, sept.-oct. 2016.
Artigo em Espanhol | LILACS | ID: biblio-835301

RESUMO

El efecto Doppler es la base científica de la flujometría láser Doppler. El efecto fue descrito por primera vez en el año de 1842 por el físico austriaco Christian Doppler en su tratado Über das farbige licht der doppelsterne und einige andere gestirne des himmels (Sobre el color de la luz en estrellas binarias y otros astros). Este principio ha permitido desarrollar técnicas y aparatos que han sido empleados en el ramo médico para medir la perfusión en diversos órganos y tejidos del cuerpo, y que han sido útiles como método diagnóstico. En la odontología, poco a poco comienza a reportarse información acerca del uso del Doppler en las diversas estructuras bucodentales, y ha demostrado ser no invasivo y de gran utilidad diagnóstica. Son pocos los estudios reportados en la rama de la odontología en cuanto a esta nueva tecnología; es importante comenzar líneas de investigación apoyadas en ella para beneficio de los pacientes.


The Doppler eff ect, the scientifi c basis of laser Doppler fl owmetry, wasfi rst described in 1842 by Austrian physicist Christian Doppler in histreatise Über das farbige Licht der doppelsterne und einige andere gestirnedes Himmels (On the Colored Light of the Binary Stars and SomeOther Stars of the Heavens). This principle has led to the developmentof techniques and devices that have been used in the fi eld of medicineto measure perfusion in various organs and tissues, and have provideda useful method of diagnosis. In dentistry, information on the use ofthis method in the various structures of the mouth has slowly begunto be published. As a result, the need for its continued use in the fi eldof oral health has become evident, given that it has proven to be noninvasiveand extremely useful in diagnosis. It is a diagnostic technique that is commonly used in healthcare and has been widely developedin the fi eld of medicine, yet there have been few reported studies of it suse in dentistry, which is an important step towards opening new linesof research based on this new technology for the benefi t of patients.


Assuntos
Humanos , Fluxometria por Laser-Doppler/normas , Fluxometria por Laser-Doppler/tendências , Odontologia/tendências , Cicatrização/efeitos da radiação , Dente/efeitos da radiação , Fraturas dos Dentes/diagnóstico , Tecnologia Odontológica/tendências , Mucosa Bucal/efeitos da radiação
19.
San Salvador; s.n; 2016. 18 p. graf.
Tese em Espanhol | BISSAL, LILACS | ID: biblio-1248279

RESUMO

Determinar la calidad del intercambio de flujo placentario que existe entre la madre y el feto es de suma importancia en situaciones que amenazan el bienestar materno-fetal, es por esto que la flujometría doppler fetal es una valiosa herramienta para prevenir daños posteriores por medio de la detección temprana y manejo oportuno de fetos con alteración del flujo placentario. La flujometría doppler es un método no invasivo que ha demostrado una mayor exactitud diagnóstica para la evaluación del bienestar fetal y una mayor sensibilidad y especificidad para diagnosticar la muerte perinatal y la baja calificación de APGAR al nacer. El presente trabajo de investigación consiste en un estudio descriptivo transversal que relacionó el resultado de la flujometría doppler fetal con los valores de APGAR a los 5 y 10 minutos en recién nacidos de embarazos mayores de 34 semanas, atendidos en el Hospital Materno Infantil 1º de Mayo en el año 2014. Los datos fueron recopilados por medio de la revisión de expedientes y procesados en la herramienta Epi InfoTM7 para su posterior interpretación. Se incluyó un total de 231 flujometrías, de las cuales se obtuvieron 209 con resultado normal y 22 alteradas, de estas últimas resultaron con APGAR debajo de 7 puntos un 40% a los 5 minutos y un 9% a los 10 minutos. En base a los resultados inferimos que la flujometría alterada tiene poco valor pronóstico de APGAR bajo al nacer, por lo que su indicación debe limitarse a embarazos con riesgo de insuficiencia placentaria, ya que realizarla de forma indiscriminada puede alterar las decisiones obstétricas e incrementar el intervencionismo médico en aquellos embarazos sin factores de riesgo


Assuntos
Gravidez/efeitos da radiação , Índice de Apgar , Fluxometria por Laser-Doppler , Ginecologia , Obstetrícia
20.
Braz. j. med. biol. res ; 49(10): e5541, 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-792524

RESUMO

Evaluation of microvascular endothelial function is essential for investigating the pathophysiology and treatment of cardiovascular and metabolic diseases. Although laser speckle contrast imaging technology is well accepted as a noninvasive methodology for assessing microvascular endothelial function, it has never been used to compare male patients with coronary artery disease with male age-matched healthy controls. Thus, the aim of this study was to determine whether laser speckle contrast imaging could be used to detect differences in the systemic microvascular functions of patients with established cardiovascular disease (n=61) and healthy age-matched subjects (n=24). Cutaneous blood flow was assessed in the skin of the forearm using laser speckle contrast imaging coupled with the transdermal iontophoretic delivery of acetylcholine and post-occlusive reactive hyperemia. The maximum increase in skin blood flow induced by acetylcholine was significantly reduced in the cardiovascular disease patients compared with the control subjects (74 vs 116%; P<0.01). With regard to post-occlusive reactive hyperemia-induced vasodilation, the patients also presented reduced responses compared to the controls (0.42±0.15 vs 0.50±0.13 APU/mmHg; P=0.04). In conclusion, laser speckle contrast imaging can identify endothelial and microvascular dysfunctions in male individuals with cardiovascular disease. Thus, this technology appears to be an efficient non-invasive technique for evaluating systemic microvascular and endothelial functions, which could be valuable as a peripheral marker of atherothrombotic diseases in men.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Doença da Artéria Coronariana/fisiopatologia , Endotélio Vascular/fisiopatologia , Fluxometria por Laser-Doppler/métodos , Microvasos/fisiopatologia , Imagem de Perfusão/métodos , Estudos de Casos e Controles , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Transversais , Endotélio Vascular/diagnóstico por imagem , Hiperemia/fisiopatologia , Microcirculação/fisiologia , Microvasos/diagnóstico por imagem , Projetos Piloto , Reprodutibilidade dos Testes , Pele/irrigação sanguínea , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...