Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 235
Filtrar
1.
Rev. bras. oftalmol ; 82: e0043, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1507881

RESUMO

ABSTRACT LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative risk factor for ectasia. The objective of this study was to assess flap thickness and calculate percentage tissue altered to check if unexpectedly thicker flaps and higher percentage tissue altered could pose as risk factors of ectasia. Four subjects (eight eyes) were submitted to mechanical LASIK in 2009 and 2010. Pre and postoperative clinical and tomographic data were reviewed. Mean preoperative estimated percentage tissue altered was 39.18±1.31%, which was borderline for increased ectasia risk when considering the limit of 40%. However, when considering the postoperatively measured flap thickness, the actual mean percentage tissue altered turned out to be 45.17 ± 4.13%, which was significantly higher than predicted preoperatively (p=0.002). Unexpectedly higher postoperative percentage tissue altered may be responsible for corneal ectasia after mechanical LASIK.


RESUMO A LASIK é um procedimento cirúrgico refrativo, no qual um retalho corneano é criado para expor o leito estromal corneano. A estimativa pré-operatória da espessura do retalho corneano é necessária para calcular o percentual de tecido alterado no LASIK, um importante fator de risco quantitativo para ectasia. O objetivo deste estudo foi avaliar a espessura do retalho e calcular o percentual de tecido alterado para verificar se retalhos inesperadamente mais espessos e percentuais de tecido alterado mais altos poderiam representar fatores de risco de ectasia. Quatro indivíduos (oito olhos) foram submetidos à LASIK mecânica em 2009 e 2010. Dados clínicos e tomográficos pré e pós-operatórios foram revisados. A média de percentual de tecido alterado pré-operatória estimada foi de 39,18±1,31%, limítrofe para risco aumentado de ectasia quando considerado o limite de 40%. No entanto, ao considerar a espessura do retalho medida no pós-operatório, o percentual de tecido alterado médio real foi de 45,17±4,13%, ou seja, significativamente maior do que o previsto no pré-operatório (p=0,002). O percentual de tecido alterado pós-operatóriao inesperadamente mais alto pode ser responsável pela ectasia da córnea após LASIK mecânico.


Assuntos
Humanos , Masculino , Feminino , Adulto , Complicações Pós-Operatórias , Retalhos Cirúrgicos/patologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Dilatação Patológica/etiologia , Lasers de Excimer/efeitos adversos , Erros de Refração , Córnea/cirurgia , Córnea/patologia , Topografia da Córnea/métodos , Tomografia de Coerência Óptica , Dilatação Patológica/diagnóstico , Procedimentos Cirúrgicos Refrativos/métodos , Lasers de Excimer/uso terapêutico
2.
Rev. bras. oftalmol ; 82: e0016, 2023. graf
Artigo em Português | LILACS | ID: biblio-1431669

RESUMO

RESUMO Objetivo: Analisar retrospectivamente as alterações na ceratometria e no astigmatismo corneano obtidas após cirurgia de implante de anel intraestromal, comparando o uso de um segmento de arco longo versus o implante de dois segmentos de comprimento de arco tradicional. Métodos: A partir de um estudo transversal, obtivemos os dados de 94 olhos de pacientes diagnosticados com ceratocone, que foram submetidos ao implante de anel corneano. Eles foram divididos em dois grupos, dependendo do tipo de implante recebido: Grupo A, um segmento de arco longo; Grupo B, dois segmentos tradicionais. Todos os segmentos implantados possuíam 250µ de espessura. Os dados do pré-operatório dos dois grupos foram comparados, para garantir que as amostras eram similares (as diferenças encontradas entre os dois grupos não eram estatisticamente significativas). As variáveis analisadas no pré e no pós-operatório foram acuidade visual com correção, ceratometria, astigmatismo corneano e refração. Resultados: A amostra que recebeu apenas um segmento de arco longo (Grupo A) obteve redução da ceratometria média de 4,42D (8,7%) e do astigmatismo corneano de 2,43D (40,4%). Já na amostra dos olhos que receberam dois segmentos de arco tradicional (Grupo B), houve redução média de 2,66D (5,1%) em relação à ceratometria média e redução média de 2,11D (34,8%) em relação ao astigmatismo corneano. A redução obtida na ceratometria média no Grupo A foi maior que a obtida no Grupo B (diferença estatisticamente significativa). A redução obtida no astigmatismo do Grupo A não foi estatisticamente significante, se comparada com o resultado obtido no Grupo B (considerando p≤0,05). Conclusão: Foi demonstrado que o uso de um segmento de arco longo possui maior capacidade de aplanação corneana, se comparado com o uso de dois segmentos com comprimento de arco tradicional. Em relação à redução do astigmatismo, os dois grupos mostraram resultados equivalentes.


ABSTRACT Purpose: To retrospectively analyze the changes in corneal keratometry and astigmatism after intrastromal ring surgery, comparing the use of one long arch segment versus two traditional arc length segments. Methods: A cross-sectional study obtained data from 94 eyes of patients diagnosed with keratoconus that underwent surgical treatment with corneal ring implant. They were divided into two groups according to the type of implant received: one long-arch segment (Group A) or two traditional segments (Group B), both 250 microns thick. Preoperative data from the two groups were compared to ensure that the samples were similar (the differences between the two groups were not statistically significant). The variables (pre and post-operatively) analyzed were: best corrected visual acuity, keratometry, corneal astigmatism and refraction. Results: Group A, which received one long arch segment, showed a Km decrease of 4.42D (8.7%) and a corneal astigmatism reduction of 2.43D (40.4%). Group B, where the eyes acquired two traditional arch segments, showed an average Km decrease of 2.66D (5.1%) and corneal astigmatism reduction of 2.11D (34.8%). The mean keratometry (Km) reduction obtained was statistically significant (p≤0.05) when comparing both groups (A and B). The mean corneal astigmatism reduction was not statistically significant (p≤0.05) when comparing both groups (A and B). Conclusions: One long-arch segment has been demonstrated to have a greater capacity to reduce corneal curvature when compared to the use of two traditional-sized arch segments. No significant differences were found regarding the reduction of corneal astigmatism after comparing the results obtained in both groups.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Próteses e Implantes , Substância Própria/cirurgia , Implantação de Prótese/métodos , Ceratocone/cirurgia , Refração Ocular , Astigmatismo , Acuidade Visual , Estudos Transversais , Resultado do Tratamento , Topografia da Córnea , Paquimetria Corneana
3.
Rev. bras. oftalmol ; 81: e0004, 2022. tab, graf
Artigo em Português | LILACS | ID: biblio-1357124

RESUMO

RESUMO A acurácia do cálculo da lente intraocular não é perfeita, podendo ser comuns erros refrativos pós-operatórios, especialmente em pacientes submetidos à cirurgia refrativa prévia ou na presença de córneas assimétricas. O poder corneano após cirurgia refrativa pode ser medido com maior acurácia utilizando o mapa de poder óptico total na zona central de 4mm, com Orbscan II ou pelo mapa equivalent keratometric reading disponível no pentacam, com medidas centrais de 1,0, 2,0, 3,0 e 4,5mm. O objetivo desta série de casos é demonstrar a abordagem de quatro olhos em condições especiais corneanas, por meio do equivalent keratometric reading do pentacam para mensuração do poder corneano e o utilizando na biometria, em comparação com possíveis resultados obtidos com outras estratégias. Os quatro olhos foram submetidos a procedimentos refrativos prévios, e a lente intraocular escolhida a partir do uso do poder corneano calculado pelo equivalent keratometric reading mostrou excelentes resultados pós-operatórios.


ABSTRACT The accuracy of the intraocular lens calculation is not perfect, and postoperative refractive errors are common, especially in patients who have undergone previous refractive surgery or in presence of asymmetric corneas. Corneal power after refractive surgery can be more accurately measured using the total optical power map in the 4-mm central zone, by means of Orbscan II or equivalent keratometric reading map available on pentacam, with central measurements of 1.0, 2.0, 3.0 and 4.5 mm. The purpose of this case series is to demonstrate four approaches performed in special corneal conditions, using pentacam equivalent keratometric reading to measure corneal power and biometrics, and comparing with possible results obtained with other strategies. The four eyes were submitted to previous refractive procedures, and the intraocular lens chosen from the use of the corneal power calculated by equivalent keratometric reading showed excellent postoperative results.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Biometria/métodos , Implante de Lente Intraocular , Procedimentos Cirúrgicos Refrativos , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Erros de Refração/fisiopatologia , Catarata/diagnóstico , Acuidade Visual , Topografia da Córnea , Microscopia com Lâmpada de Fenda , Lentes Intraoculares
4.
Rev. bras. oftalmol ; 81: e0058, 2022. tab
Artigo em Inglês | LILACS | ID: biblio-1394861

RESUMO

ABSTRACT Objective To analyze and describe the coefficients found on maximum Ambrósio Relational Thickness-Maximum (ART-Max) and Belin/Ambrósio Enhanced Ectasia Display total deviation (BAD-D) in eyes with normal corneal topography subjected to cataract surgery with premium intraocular lens implantation and correlated these data with final visual acuity. Methods ART-Max and BAD-D data from 103 eyes of patients subjected to implantation of diffractive bifocal intraocular lens, with normal corneal topography who achieved visual acuity of 20/20 or 20/25 without correction after cataract surgery were analyzed. The groups with normal and abnormal values were compared using the chi-square test. Results Thirty-two (31.1%) and 71 (68.9%) eyes presented normal and abnormal ART-Max values, respectively. The difference between these groups was significant (p=0.0002). Fifty-five (53.4%) and 48 (46.6%) eyes had normal and abnormal BAD-D, respectively, and intergroup difference was not significant (p=0.9576). Conclusion Among patients with normal corneal topography who underwent premium intraocular and had good final visual acuity of 20/20 or 20/25, suspicious or abnormal indices of ART-Max and BAD-D were frequent, providing evidence that it possibly should not be a contraindication.


RESUMO Objetivo Analisar e descrever os coeficientes numéricos encontrados nos exames Ambrósio Relational Thickness-Maximum (ART-Max) e desvio total do Belin/Ambrósio Enhanced Ectasia Display (BAD-D) em olhos com topografia normal submetidos ao implante de lente intraocular premium na cirurgia de catarata, correlacionando-os com a acuidade visual final pós-operatória. Métodos Foram analisados os resultados de ART-Max e BAD-D de 103 olhos de pacientes submetidos ao implante de lentes bifocais difrativas, que apresentavam exame topográficos normal e alcançaram acuidade visual 20/20 ou 20/25 sem correção visual no pós-operatório final. Para a análise estatística entre os grupos normais e anormais ou suspeitos, utilizou-se o teste do qui-quadrado. Resultados Foram encontrados 32 (31,1%) olhos com ART-Max normal e 71 (68,9%) com ART-Max suspeito/anormal. A diferença entre os grupos foi significativa (p=0,0002). Quanto ao BAD-D, foram encontrados 55 (53,4%) olhos com resultados normais e 48 (46,6%) com resultados suspeitos/anormais. A diferença entre os grupos não foi significativa (p=0,9576). Conclusão Entre os pacientes com topografia normal submetidos ao implante de lentes premium e que alcançaram acuidade visual 20/20 ou 20/25, os índices suspeitos ou anormais de ART-Max e BAD-D eram frequentes, não se configurando em contraindicação para a realização do implante.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Erros de Refração/prevenção & controle , Acuidade Visual/fisiologia , Córnea/patologia , Doenças da Córnea/diagnóstico , Topografia da Córnea/métodos , Dilatação Patológica/diagnóstico , Complicações Pós-Operatórias , Extração de Catarata/efeitos adversos , Estudos Retrospectivos , Curva ROC , Doenças da Córnea/etiologia , Implante de Lente Intraocular/efeitos adversos , Paquimetria Corneana/métodos
5.
Arq. bras. oftalmol ; 84(4): 324-329, July-Aug. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1285298

RESUMO

ABSTRACT Purpose: Keratoconus presents certain specificities in pediatric patients compared with adults. The greatest challenge is because the disease is typically more severe and progresses faster in children. This retrospective study aimed to report crosslinking procedure in patients under 18 years of age and their follow-up for at least 24 months after the procedure. Methods: Overall, 12 eyes from 10 patients were studied and data, such as visual acuity with and without correction, maximum keratometry, corneal thickness, foveal thickness, and endothelial microscopy, were assessed at both preoperative and postoperative visits. Corneal crosslinking was performed in all patients. Results: A tendency toward reduced Kmax and improved Corrected Distance Visual Acuity at all postoperative moments. Only one of the 12 eyes exhibited increased Kmax of more than 1 D during a time frame longer than 12 months. Regarding pachymetry, a tendency for corneal thinning was observed in the first four months after surgery. Conclusion: Encouraging results were obtained regarding the stabilization of the disease, progression, and procedural safety, corroborating to other authors' findings. The significance of early diagnosis and short-term follow-up were highlighted.


RESUMO Objetivo: O ceratocone na população pediátrica apresenta algumas particularidades em relação à população adulta. O maior desafio é devido à doença ser geralmente mais severa e rapidamente progressiva em crianças. Métodos: Este artigo utiliza uma análise retrospectiva para relatar o uso do crosslinking em jovens menores de 18 anos e sua evolução pelo menos 24 meses após o procedimento. Foram estudados 12 olhos de 10 pacientes, e dados como acuidade visual com e sem correção, ceratometria máxima, espessura corneana, espessura foveal e microscopia endotelial avaliados no pré e pós-operatórios. O crosslinking corneano foi realizado em todos os pacientes pelo mesmo cirurgião. Resultados: Observou-se uma tendência de redução do valor do Kmax e melhora da acuidade visual corrigida em todos os momentos de pós operatório. Com relação à paquimetria, observou-se afinamento corneano do ponto mais fino, nos primeiros quatro meses de pós-operatório. Conclusão: Resultados encorajadores foram obtidos com relação à estabilização da doença, progressão e segurança do procedimento, corroborando com as conclusões de outros autores. A importância do diagnóstico precoce e do acompanhamento a curto prazo do paciente deve ser destacada.


Assuntos
Adolescente , Adulto , Criança , Humanos , Fotoquimioterapia , Ceratocone , Riboflavina/uso terapêutico , Raios Ultravioleta , Estudos Retrospectivos , Colágeno/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Córnea , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Paquimetria Corneana , Ceratocone/cirurgia , Ceratocone/tratamento farmacológico
6.
Medisan ; 25(3)2021. tab
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1287302

RESUMO

Introducción: La operación de pterigión se exige como habilidad desde el primer año de residencia y la evaluación topográfica es clave para evaluar las modificaciones corneales y perfeccionar las habilidades clinicoquirúrgicas de los cirujanos en formación. Objetivo: Determinar las modificaciones corneales en pacientes operados de pterigión en el Centro Oftalmológico de Santiago de Cuba. Métodos: Se realizó un estudio descriptivo, prospectivo y transversal de 53 pacientes operados de pterigión en el Centro Oftalmológico de Santiago de Cuba, desde enero de 2019 hasta igual mes de 2021, a los cuales se les evaluó topográficamente antes y después de la intervención quirúrgica. Resultados: Predominaron el sexo femenino (60,4 %), el grupo etario de 40-49 años (5,8 %), el grado II de la enfermedad (43,4 %) y el astigmatismo inducido como complicación más frecuente (33,9 %). El poder corneal promedio sufrió variación de 43,25D a 45,75D y el astigmatismo topográfico descendió de 4,75 a 3,55 D. Conclusiones: Con el uso de la topografía se comprobó que existen modificaciones corneales importantes derivadas de la invasión del pterigión en la córnea y de la manipulación quirúrgica.


Introduction: Pterigium surgery is demanded as a skill in the first year of the residency and the topographical evaluation is a key element to evaluate corneal modifications and to improve clinical -surgical skill of training surgeons. Objective: To determine the corneal modifications in patients with pterigium surgery in the Ophthalmological Center from Santiago de Cuba, from January 2019 to the same month in 2021, in whom a topographical evaluation was carried out before and after the surgical procedure. Results: Female sex (60.4 %), age group 40-49 (5.8 %), the disease grade II (43.4 %) and induced astigmatism as the most frequent complication (33.9 %) predominated. Average corneal power suffered a variation of 43.25 D and 45.75 and the topographical astismatism decreased from 4.75 to 3.55 D. Conclusions: With the use of topography it was proven that there are corneal modifications derived from pterigium invasion to the cornea and from the surgical manipulation.


Assuntos
Competência Profissional , Pterígio/cirurgia , Astigmatismo , Topografia da Córnea/métodos
7.
Arq. bras. oftalmol ; 84(2): 107-112, Mar,-Apr. 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1153113

RESUMO

ABSTRACT Purpose: To investigate the effects of pharmacological accommodation and cycloplegia on ocular measurements. Methods: Thirty-three healthy subjects [mean (±SD) age, 32.97 (±5.21) years] volunteered to participate in the study. Measurement of the axial length, macular and choroidal thickness, refractive error, and corneal topography, as well as anterior segment imaging, were performed. After these procedures, pharmacological accommodation was induced by applying pilocarpine eye drops (pilocarpine hydrochloride 2%), and the measurements were repeated. The measurements were repeated again after full cycloplegia was induced using cyclopentolate eye drops (cyclopentolate hydrochloride 1%). The correlations between the measurements were evaluated. Results: A significant increase in subfoveal choroidal thickness after applying 2% pilocarpine was identified (without the drops, 319.36 ± 90.08 µm; with pilocarpine instillation, 341.60 ± 99.19 µm; with cyclopentolate instillation, 318.36 ± 103.0 µm; p<0.001). A significant increase in the axial length was also detected (without the drops, 23.26 ± 0.83 mm; with pilocarpine instillation, 23.29 ± 0.84 mm; with cyclopentolate instillation, 23.27 ± 0.84 mm; p=0.003). Comparing pharmacological accommodation and cycloplegia revealed a significant difference in central macular thickness (with pilocarpine instillation, 262.27 ± 19.34 µm; with cyclopentolate instillation, 265.93 ± 17.91 µm; p=0.016). Pilocarpine-related miosis (p<0.001) and myopic shift (p<0.001) were more severe in blue eyes vs. brown eyes. Conclusion: Pharmacological accommodation may change ocular measurements, such as choroidal thickness and axial length. This condition should be considered when performing ocular measurements, such as intraocular lens power calculations.(AU)


RESUMO Objetivo: Investigar os efeitos da acomodação farmacológica e da cicloplegia nas medições oculares. Métodos: participaram do estudo 33 voluntários saudáveis (média de idade [± DP], 32,97 anos [± 5,21 anos]). Foram medidos o comprimento axial, a espessura macular e coroidal e o erro refrativo, bem como realizados exames de imagem da topografia corneana e do segmento anterior. Em seguida, foi induzida a acomodação farmacológica aplicando-se colírio de pilocarpina (cloridrato de pilocarpina a 2%) e as medições foram repetidas nos participantes. As mesmas medições foram repetidas depois de induzir a cicloplegia completa com colírio de ciclopentolato (cloridrato de ciclopentolato a 1%) e foram avaliadas as correlações entre as medidas. Resultados: Identificou-se aumento significativo da espessura coroidal subfoveal com o uso da pilocarpina a 2% (sem colírio, 319,36 ± 90,08 µm; com a instilação de pilocarpina, 341,60 ± 99,19 µm; com a instilação de ciclopentolato, 318,36 ± 103,0 µm; p<0,001). Detectou-se também aumento significativo do comprimento axial (sem colírio, 23,26 ± 0,83 mm; com a instilação de pilocarpina, 23,29 ± 0,84 mm; com a instilação de ciclopentolato, 23,27 ± 0,84 mm; p=0,003). Ao se comparar a acomodação farmacológica e a cicloplegia, houve diferença significativa na espessura macular central (com a instilação de pilocarpina, 262,27 ± 19,34 µm; com a instilação de ciclopentolato, 265,93 ± 17,91 µm; p=0,016). Observou-se que a miose associada à pilocarpina (p<0,001) e o desvio miópico (p<0,001) foram mais severos nos olhos azuis que nos castanhos. Conclusão: A acomodação farmacológica pode alterar medidas oculares como a espessura da coroide e o comprimento axial. Essa possibilidade deve ser levada em consideração ao se efetuarem medições oculares, tais como cálculos de potência de lentes intraoculares.(AU)


Assuntos
Humanos , Corioide/anatomia & histologia , Acomodação Ocular , Pilocarpina/farmacologia , Topografia da Córnea/instrumentação , Comprimento Axial do Olho/anatomia & histologia , Midriáticos/farmacologia
8.
Rev. bras. oftalmol ; 80(2): 143-145, Mar.-Apr. 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1280101

RESUMO

ABSTRACT A 27-year-old healthy man with a history of bilateral photorefractive keratectomy (PRK) enhancement after femtosecond laser in situ keratomileusis (LASIK) presented with decreased uncorrected distance visual acuity (UDVA) of 20/125 in the right eye (OD) and 20/300 in the left eye (OS) six months after PRK. Examination revealed bilateral dense subepithelial opacities. Both eyes (OU) were treated with superficial keratectomy combined with phototherapeutic keratectomy (PTK) and adjunctive application of mitomycin C 0.02%. At three months follow up UDVA was 20/30 OD and 20/25 OS. Superficial keratectomy combined with PTK seems to be a safe and efficient technique for treatment of dense subepithelial scar formation following PRK enhancement after LASIK.


RESUMO Um homem saudável de 27 anos de idade com história de aprimoramento com ceratectomia fotorrefrativa (PRK) bilateral, após Ceratomileuse Assistida por Excimer Laser In Situ (LASIK) com laser de femtossegundos, apresentou diminuição da acuidade visual à distância não corrigida (AVNC) de 20/125 no olho direito (OD) e 20/300 no olho esquerdo (OE) seis meses após PRK. O exame revelou opacidades subepiteliais densas bilaterais. Ambos os olhos (AO) foram tratados com queratectomia superficial combinada com ceratectomia fototerapêutica (PTK) e aplicação adjuvante de mitomicina C a 0,02%. Aos três meses de acompanhamento, o AVNC foi de 20/30 OD e 20/25 OE. A ceratectomia superficial combinada com PTK parece ser uma técnica segura e eficiente para o tratamento da formação densa de cicatrizes subepiteliais após o aprimoramento com PRK pós-LASIK.


Assuntos
Humanos , Masculino , Adulto , Fibrose/terapia , Ceratectomia Fotorrefrativa/efeitos adversos , Cicatrização , Fibrose/etiologia , Acuidade Visual , Mitomicina/administração & dosagem , Ceratectomia Fotorrefrativa/métodos , Opacidade da Córnea/diagnóstico , Opacidade da Córnea/etiologia , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Desbridamento , Cirurgia da Córnea a Laser , Microscopia com Lâmpada de Fenda , Miopia/cirurgia
9.
Rev. bras. oftalmol ; 80(2): 107-110, Mar.-Apr. 2021. tab, graf
Artigo em Português | LILACS | ID: biblio-1280108

RESUMO

RESUMO Objetivo: Avaliar a contagem endotelial da córnea em pacientes com ceratocone (KCN) por microscopia especular e correlacionar com o estágio do ceratocone. Métodos: Noventa e três olhos de 61 pacientes com KCN foram incluídos neste estudo transversal. Os olhos foram classificados nos estágios 1 a 4 de KCN de acordo com a classificação de Amsler-Krumeich utilizando ceratometria obtida pela topografia de córnea e leituras de paquimetria obtidas pela microscopia especular. Resultados: A idade variou de 12 a 43 anos, média ± (desvio padrão) 22,1 ± 6,7 anos. A ceratometria média variou de 42,25 a 71,4 D (53,0 ± 6,1 D). A paquimetria variou de 350 a 606 µm, (461,7 ± 47,1 µm). Em relação a classificação, 23 pacientes (24,7%) apresentavam estágio 1, 24 (25,8%) estágio 2, 5 (6,5%) estágio 3 e 41 pacientes (44,1%) estágio 4. Não foi observada correlação linear entre ceratometria média e contagem de células endoteliais (Coeficiente de correlação de Pearson = -0,05). Nos estágios iniciais a moderados de KCN, a média da contagem de células endoteliais foi 2738,3 ± 285,4 cel/mm2, enquanto no grupo de KCN avançado (estágios 3 e 4) foi 2670,6 ± 262,7 cel/mm2, p= 0,24. Conclusões: Não há correlação entre a contagem de células endoteliais e o estágio do KCN.


ABSTRACT Objective: To evaluate the corneal endothelial count in patients with keratoconus (KCN) by specular microscopy and correlate with the stage of keratoconus. Methods: Ninety-three eyes from 61 patients with KCN were included in this cross-sectional study. The eyes were classified into KCN stages 1 to 4 according to the Amsler-Krumeich classification using keratometry obtained by corneal topography and pachymetry readings obtained by specular microscopy. Results: Age ranged from 12 to 43 years, mean ± (standard deviation) 22.1 ± 6.7 years. The average keratometry ranged from 42.25 to 71.4 D, (53.0 ± 6.1 D). Pachymetry ranged from 350 to 606 µm, (461.7 ± 47.1 µm). Regarding the Amsler classification, 23 patients (24.7%) had stage 1, 24 (25.8%) stage 2, 5 (6.5%) stage 3 and 41 patients (44.1%) stage 4. No linear correlation was observed between mean keratometry and endothelial cell count (Pearson's correlation coefficient = -0.05). In the early to moderate stages of KCN, the mean endothelial cell count was 2738.3 ± 285.4 cell / mm2, while in the advanced KCN group (stages 3 and 4) it was 2670.6 ± 262.7 cell / mm2 , p = 0.24. Conclusions: No correlation was found between the endothelial cell count and the KCN stage.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Células Endoteliais , Ceratocone/diagnóstico , Microscopia , Endotélio Corneano , Contagem de Células , Estudos Transversais , Topografia da Córnea , Paquimetria Corneana
10.
Rev. bras. oftalmol ; 80(2): 136-139, Mar.-Apr. 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1280110

RESUMO

ABSTRACT We report a case of two twins for whom advanced keratoconus is present in one of the siblings and no clear sign of the disease could be found for the other.


RESUMO Relatamos um caso de dois gêmeos em que o ceratocone avançado está presente em um dos irmãos e nenhum sinal da doença foi encontrado no outro.


Assuntos
Humanos , Masculino , Adulto , Ceratocone/diagnóstico , Gêmeos , Tomografia , Acuidade Visual , Doenças da Córnea/diagnóstico , Topografia da Córnea , Ceratocone/genética
11.
Rev. bras. oftalmol ; 80(1): 71-76, jan.-fev. 2021. tab, graf
Artigo em Português | LILACS | ID: biblio-1251315

RESUMO

RESUMO O artigo tem como objetivo descrever de forma prospectiva diferentes casos de ectasias altamente assimétricas (very asymmetric ectasia, VAE) para diferenciar formas subclínicas ou "frustas" do ceratocone (forme fruste keratoconus - FFKC) de casos de doença ectásica unilateral. O Caso 1 é um paciente de 39 anos, que admitiu ter coçado intensamente apenas o olho direito (OD) na juventude, se apresentando com ectasia unilateral tratada com sucesso por meio de implante de anel intraestromal em OD. O olho esquerdo (OE) apresentou-se normal ao exame completo por meio de propedêutica multimodal e acuidade visual não corrigida (AVsc) de 20/20, estável por mais de 5 anos, com TBI (tomography and biomechanical index) de 0.02. No Caso 2 é um paciente de 15 anos com ectasia clínica em OD, e OE com topografia normal, mas alterações tomográficas e biomecânicas, incluindo o TBI 0,56, caracterizarando a doença subclínica (FFKC). O Caso 3 é a mãe do paciente do Caso 2, de 46 anos, que se apresentou com presbiopia, sem qualquer histórico oftalmológico relevante. A AVsc foi de 20/20 em cada olho, topografia de Placido com leve encurvamento inferior, mas sem sinais definitivos de ectasia. A avaliação biomecânica e tomográfica revelou sinais de ceratocone em ambos os olhos, com TBI de 1,0 e 0,99. Esses três casos estão de acordo com a definição do consenso global e a hipótese de dois acertos (two-hit hypothesis), que ceratocone é uma doença bilateral, mas ectasia pode ocorrer por causa estritamente mecânica unilateralmente (ou em qualquer olho). A relevância da propedêutica multimodal é destacada, destacando-se a integração do estudo biomecânico e tomográfico com imagens de Scheimpflug.


ABSTRACT The article aims to prospectively describe different cases of highly asymmetric ectasia (very asymmetric ectasia, VAE) to differentiate subclinical or "frustrated" forms of keratoconus (forme fruste keratoconus - FFKC) from cases of unilateral ectatic disease. Case 1 is a 39-year-old patient with unilateral ectasia treated with an intrastromal ring implant. The contralateral eye was normal due to multimodal propaedeutics, stable for more than 3 years, with a TBI of 0.02. The patient admitted to having intensely scratched only his right eye in his youth. In Case 2, a 15-year-old patient with clinical ectasia in the right eye, had a left eye with normal topography and tomographic and biomechanical changes characterizing FFKC. Case 3 is the mother of the case 2 patient, aged 46, who presented with presbyopia, without any relevant ophthalmological history. Uncorrected visual acuity of 20/20 in each eye, Placido topography with slight lower curving, but without definitive signs of ectasia. The biomechanical and tomographic evaluation revealed signs of keratoconus in both eyes. These three cases are in accordance with the definition of the global consensus: keratoconus is a bilateral disease, but ectasia can occur because of strictly mechanical unilateral (in any eye). The relevance of multimodal refractive imaging is highlighted, with a focus on integrating biomechanical and tomographic assessments with Scheimpflug images.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Tomografia/métodos , Topografia da Córnea/métodos , Dilatação Patológica , Ceratocone/diagnóstico , Epidemiologia Descritiva
12.
Arq. bras. oftalmol ; 84(1): 11-16, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1153094

RESUMO

ABSTRACT Purpose: To determine the effect of upper blepharoplasty on corneal topography and intraocular lens power calculation using Galilei and IOLMaster. Methods: Thirty patients submitted to upper blepharoplasty from May 2014 to March 2017 at the Hospital Oftalmológico de Sorocaba (São Paulo, Brazil) were included in this observational case series. All patients underwent imaging sessions with Galilei and IOLMaster preoperatively (baseline) and at 1 and 6 months postoperatively. Primary outcome measures using both devices included flattest, average, and steepest corneal curvature, corneal astigmatism, and blepharoplasty-induced corneal astigmatism. Determination of axial length and lens power calculation were performed using only IOLMaster (Holladay formula). Paired t-test and vectorial analysis were used for statistical analysis. Results: Sixty eyes from 30 patients were prospectively included. Vectorial analysis showed that 6 months after surgery, blepharoplasty induced on average 0.39 D and 0.31 D of corneal astigmatism, as measured with Galilei and IOLMaster, respectively. IOLMaster measurements showed that average corneal curvature (44.56 vs 44.64 D, p=0.01), steepest corneal curvature (45.17 vs 45.31, p=0.01) and corneal astigmatism (1.22 vs 1.34, p=0.03) were higher 6 months after surgery. IOLMaster measurements also showed that intraocular lens power was significantly smaller 6 months after surgery (22.07 vs 21.93, p=0.004). All other parameters showed no change for comparisons between baseline and 6 months (p>0.05 for all comparisons). Conclusion: Upper eyelid blepharoplasty influenced intraocular lens calculation using the IOLMaster. However, the influence was not clinically significant. No topographic changes were found using Galilei.


RESUMO Objetivo: Determinar o efeito da blefaroplastia superior na topografia corneana e no cálculo do poder das lentes intraoculares usando Galilei e IOLMaster. Métodos: Trinta pacientes submetidos a blefaroplastia superior de maio de 2014 a março de 2017 no Hospital Oftalmológico de Sorocaba, São Paulo, Brasil foram incluídos neste estudo de série de casos observacional. Todos os pacientes foram submetidos a sessões de imagem com Galilei e IOLMaster antes da cirurgia (exame de base) e no 1º e 6º mês pós-operatório. Os resultados primários utilizando os dois aparelhos incluíram ceratometria, astigmatismo corenano e astigmatismo corneano induzido pela blefaroplastia. O comprimento axial e o cálculo do poder da lente intraocular foram realizados unicamente com o IOLMaster (fórmula de Holladay). Teste-t pareado e análise vetorial foram usados na análise estatística. Resultados: Sessenta olhos de 30 pacientes foram incluídos prospectivamente. A análise vec­torial mostrou que após 6 meses da cirurgia, a blefaroplastia superior induziu na média 0,39 D de astigmatismo corneano medido com o Galilei e 0,31 D com IOLMaster. As medidas com o IOLMaster mostraram que a ceratometria média (44,56 vs 44,64 D, p=0,01), ceratometria máxima (45,17 vs 45,31, p=0,01) e o astigmatismo corneano (1,22 vs 1,34, p=0,03) foram maiores após 6 meses da blefaroplastia. As medidas com IOLMaster mostraram que o poder da lente intraocular foi significativamente menor 6 meses após a blefaroplastia (22,07 vs 21,93, p=0,004). Todos os outros parâmetros não mostraram mudanças entre o pré-operatório e o 6º mês da cirurgia (p>0,05 para todas as comparações). Conclusões: A blefaroplastia superior influenciou o cálculo da lente intrao­cular utilizando o IOLMaster. Contudo, a influência não foi cli­­nicamente significativa. Não foram encontradas mudanças topográficas com o Galilei.


Assuntos
Humanos , Astigmatismo , Astigmatismo/etiologia , Biometria , Blefaroplastia , Lentes Intraoculares , Refração Ocular , Brasil , Córnea/cirurgia , Córnea/diagnóstico por imagem , Topografia da Córnea , Blefaroplastia/efeitos adversos , Implante de Lente Intraocular , Pálpebras
13.
Arq. bras. oftalmol ; 84(1): 17-21, Jan.-Feb. 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1153101

RESUMO

ABSTRACT Purpose: To compare the severity and laterality of keratoconus according to allergic rhinitis, scratching and sleeping habits, and manual dexterity. Methods: Objective assessments regarding allergic rhinitis, eye itching, and slee­ping position among patients with keratoconus (diagnosed based on corneal tomography) were conducted. Diagnostic criteria and classification were based on the Amsler-Krumeich classification. Results: Ocular pruritus was reported by 29 of 34 participants (85.29%). Eighteen participants (62.07%) reported equal scratching of both eyes, six (20.69%) more on the right eye, and five (17.24%) more on the left eye. Comparison of the main sleeping position and the eye with more severe presentation of the disease using Fisher's exact test revealed some correlations (0.567 and 0.568 in the right and left eye, respectively). However, these correlations were not statistically significant. Conclusions: The association between higher keratometry values and sleeping position appears to be more significant than that reported between keratometry and itching, or manual dexterity.


RESUMO Objetivo: Comparar a gravidade e a lateralidade do ceratocone de acordo com a rinite alérgica, os hábitos de coçar e dormir e a destreza manual. Métodos: Foram realizadas questões objetivas sobre rinite alérgica, prurido ocular e posi­ção do sono em pacientes com ceratocone, diagnosticados com base na tomografia corneana. Esses exames foram analisados e classificados de acordo com a classificação de Amsler-Krumeich. Resultados: O prurido ocular foi referido por 29 (85,29%) dos 34 voluntários. Dezoito sujeitos (62,07%) relataram coçar ambos os olhos igualmente, 6 (20,69%) mais no olho direito e 5 (17,24%) mais no olho esquerdo. Comparando-se a posição de dormir principal e o olhos com apresentação mais grave da doença, foi encontrada alguma relação baseada no teste exato de Fisher (0,567 no olho direito e 0,568 no olho esquerdo), embora nenhuma comparação parecesse estatisticamente significante. Conclusões: A associação entre maiores valores de ceratometria e posição do sono parece ser mais importante do que entre ceratometria e prurido ou destreza manual.


Assuntos
Humanos , Córnea , Topografia da Córnea , Hipersensibilidade , Ceratocone , Visão Ocular , Ceratocone/diagnóstico
14.
Rev. bras. oftalmol ; 80(6): e0053, 2021. tab, graf
Artigo em Português | LILACS | ID: biblio-1351855

RESUMO

RESUMO Objetivo: Avaliar retrospectivamente a influência da espessura do anel intracorneano na redução do astigmatismo corneano em pacientes portadores de ceratocone. Métodos: De um banco de dados com 2.033 olhos submetidos à cirurgia de implante de anel corneano, foi selecionada uma amostra de 90 olhos com características semelhantes em relação à ceratometria e ao astigmatismo. Todos os olhos deste estudo receberam dois segmentos de comprimento de arco tradicional de aproximadamente 160°, com espessuras variadas: Grupo A recebeu dois segmentos de 150µm; Grupo B recebeu dois segmentos de 200µm, e Grupo C recebeu dois segmentos de 250µm. As variáveis analisadas foram ceratometria média e astigmatismo corneano pré e pós-operatório. Resultados: Nos olhos que receberam dois segmentos de anel de 150µm de espessura (Grupo A), houve redução média de 5,0D (10%) em relação à ceratometria média e redução média de 3,26D (57,69%) em relação ao astigmatismo corneano. Na amostra em que foram utilizados dois segmentos de 200µm (Grupo B), foi observada redução da ceratometria média de 7,0D (14,28%) e do astigmatismo corneano de 3,53D (63,6%). Já na amostra que recebeu dois segmentos de anel de 250µm de espessura (Grupo C), a redução média da ceratometria foi de 10D (20,4%) e de seu astigmatismo corneano de 2,09D (38,99%). Conclusão: Nos pacientes com ceratocone submetidos à cirurgia de anel corneano, o aumento da espessura dos segmentos implantados promove maior aplanamento da córnea, mas não o aumento em sua capacidade de reduzir o astigmatismo ceratométrico. Seria interessante a análise de uma amostra maior de pacientes, aliada a cálculos vetoriais de astigmatismo, para comprovar os achados deste estudo.


ABSTRACT Objective: To retrospectively evaluate the influence of intracorneal ring thickness on reduction of corneal astigmatism in patients with keratoconus. Methods: From a database of 2,033 eyes submitted to corneal ring implant surgery, a sample of 90 eyes with similar keratometry and astigmatism characteristics was selected. All eyes in this study received two segments of traditional arc length of approximately 160°, with varying thicknesses: Group A received two segments of 150 µm; Group B received two segments of 200 µm, and Group C received two segments of 250 µm. The variables analyzed were mean keratometry and corneal astigmatism before and after surgery. Results: In the eyes that received two 150-µm ring segments (Group A), there was a mean reduction of 5.0 D (10%) in relation to mean keratometry, and a mean reduction of 3.26 D (57.69%) in relation to corneal astigmatism. In the sample in which two 200-µm segments (Group B) were used, there was a mean reduction in keratometry of 7.0 D (14.28%) and in corneal astigmatism of 3.53 D (63.6%). In the sample receiving two 250-µm ring segments (Group C), the mean reduction in keratometry was 10 D (20.4%) and in corneal astigmatism was 2.09 D (38.99%). Conclusion: In keratoconus patients undergoing corneal ring surgery, increased thickness of the implanted segments promotes greater flattening of the cornea, but does not enhance their ability to reduce corneal astigmatism. It would be interesting to analyze a larger sample of patients, combined with vector calculations of astigmatism, to confirm the findings of this study.


Assuntos
Humanos , Adolescente , Adulto , Pessoa de Meia-Idade , Astigmatismo/cirurgia , Implantação de Prótese , Ceratocone/cirurgia , Próteses e Implantes , Astigmatismo/etiologia , Acuidade Visual , Topografia da Córnea , Ceratocone/complicações
15.
Rev. bras. oftalmol ; 80(3): e0011, 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1280118

RESUMO

ABSTRACT The authors report the case of a male adult presenting significant ocular complications and irreversible visual impairment, resulting from the long-term progression and late diagnosis of an iris cyst in the right eye, probably secondary to trauma. The patient was admitted to Hospital Universitário Antonio Pedro with a total corneal opacity that blocked direct visualization of the anterior chamber. Ultrasound biomicroscopy was crucial for the anatomic study, and the patient was submitted to enucleation for aesthetic improvement and clarifying diagnosis. We concluded athalamia and deformation of the anterior segment, due to expansion of the cyst, led to gradual elevation of the intraocular pressure and damage of the optic nerve, resulting in visual loss.


RESUMO Relatamos o caso de um paciente com evolução e diagnóstico tardios de cisto de íris no olho direito, provavelmente secundário a trauma, com complicações importantes e baixa irreversível da visão, tendo sido admitido no Hospital Universitário Antônio Pedro já com leucoma total da córnea e câmara anterior indevassável. A biomicroscopia ultrassônica se mostrou imprescindível para o estudo anatômico, sendo o paciente finalmente submetido à enucleação, para melhora estética e elucidação diagnóstica. Concluímos que a atalamia e a desestruturação do segmento anterior, consequentes ao crescimento cístico, levaram a um gradativo aumento da pressão intraocular e lesão do nervo óptico, com consequente perda da visão.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Cistos/complicações , Cistos/diagnóstico , Doenças da Íris/diagnóstico , Oftalmoscopia , Tonometria Ocular/métodos , Imageamento por Ressonância Magnética , Enucleação Ocular , Acuidade Visual , Iris/diagnóstico por imagem , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/etiologia , Cegueira/etiologia , Topografia da Córnea , Cistos/cirurgia , Cistos/patologia , Paquimetria Corneana , Microscopia com Lâmpada de Fenda/métodos , Doenças da Íris/cirurgia , Doenças da Íris/complicações , Doenças da Íris/patologia
16.
Rev. bras. oftalmol ; 80(4): e0016, 2021. tab
Artigo em Português | LILACS | ID: biblio-1288633

RESUMO

RESUMO Objetivo: Avaliar a possibilidade de alterações precoces sugestivas de ectasia detectáveis no Pentacam em casos sutis de alergia ocular em crianças. Métodos: Análise retrospectiva de 49 prontuários, com paciente de ambos os sexos e idades entre 3 e 14 anos. Do total de crianças estudadas, 31 apresentavam alergia ocular grau 1, e 18 não apresentavam qualquer sinal ou sintoma de alergia ocular, servindo como controles. Avaliaram-se diversos índices do Pentacam. Resultados: Houve associação estatisticamente significativa nas variáveis "Df - variação do mapa da elevação anterior da córnea" e "Pentacam combinado", que podem estar relacionadas com a detecção precoce de ectasia corneana nesses pacientes. Conclusão: Houve relação causal entre a prevalência da alergia ocular e alterações tomográficas na córnea, sugestivas de ceratocone em alguns pacientes provavelmente suscetíveis, podendo ser considerado um fator de risco para essa complicação.


ABSTRACT Objective: To assess if early alterations detected by Pentacam in children suffering from mild ocular allergy are suggestive of ectasia. Methods: A retrospective analysis of 49 medical records of patients of both sexes, aged between 3 and 14 years was performed. In this sample, 31 children suffered from grade I ocular allergy, and 18 presented no signs or symptoms of ocular allergy and comprised the control group. Several Pentacam indexes were evaluated. Results: A statistically significant association was found in the variables "Df - variation of the anterior corneal elevation map" and "combined Pentacam", which can be related to the early detection of corneal ectasia in these patients. Conclusion: There was a causal relation between prevalence of ocular allergy and tomographic alterations on the cornea, suggestive of keratoconus in some probably susceptible patients, which may be considered a risk factor for this complication.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Conjuntivite Alérgica/complicações , Conjuntivite Alérgica/etiologia , Ceratocone/diagnóstico , Ceratocone/etiologia , Ceratocone/epidemiologia , Estudos Retrospectivos , Topografia da Córnea , Técnicas de Diagnóstico Oftalmológico
17.
Rev. bras. oftalmol ; 80(3): e0003, 2021. tab
Artigo em Português | LILACS | ID: biblio-1251330

RESUMO

RESUMO Objetivo: Avaliar sensibilidade do volume corneano, asfericidade e índice D para o diagnóstico precoce de ceratocone. Métodos: Estudo transversal analítico, realizado entre dezembro de 2018 e outubro de 2020, no qual foram analisados os prontuários de 39 pacientes (78 olhos) diagnosticados com ceratocone por um único subespecialista em córnea, por meio dos critérios de Belin/Ambrosio Enhanced Ectasia. Os dados coletados foram: asfericidade anterior, asfericidade posterior, índice D e suas frações (Da, Db, Dt, Dp e Df). Os dados foram digitados e manipulados em Excel, para posterior tratamento utilizando o programa Statistical Package for Social Science do Windows, versão 21.0. As variáveis categóricas foram apresentadas como valor absoluto e percentual. Variáveis contínuas foram apresentadas como média ± desvio-padrão e mediana (intervalo de confiança de 95%). Resultados: Foram analisados 78 olhos, com idade média de 28,2±5,8 anos e porcentagem entre o sexo feminino e masculino de 59,0% e 41,0%, respectivamente. O índice D apresentou estreita relação com sua fração Db nos casos iniciais de ceratocone, enquanto a fração Dt apresentou tal relação de forma reduzida. Conclusão: A correlação entre o índice D e sua fração Db sugere alterações precoces na elevação corneana posterior, colaborando para o diagnóstico de ceratocone subclínico.


ABSTRACT Objective: To assess sensitivity of corneal volume, corneal asphericity, and D index in early diagnosis of keratoconus. Methods: A cross-sectional analytical study, carried out between December 2018 and October 2020, which analyzed the medical records of 39 patients (78 eyes) diagnosed as keratoconus by a single corneal specialist, using the criteria of Belin-Ambrosio Enhanced Ectasia Display. The collected data were anterior asphericity, posterior asphericity, D index and its parameters (Da, Db, Dt, Dp and Df). The data were entered and handled in Excel, for later data treatment using the software Statistical Package for Social Science, version 21.0, for Windows. The categorical variables were presented as absolute value and percentages. The continuous variables were presented as mean±standard deviation, and median (95% of confidence interval). Results: We analyzed 78 eyes, mean age of 28.2±5.8 years, 59.0% of sample were female, and 41.0%, male. The D index showed a close relation to its Db parameter in the cases of keratoconus at early stage, while Dt parameter showed a reduced relation. Conclusion: The correlation between the D index and its Db parameter suggests early changes in the posterior corneal elevation, contributing to early diagnosis of subclinical keratoconus.


Assuntos
Humanos , Masculino , Feminino , Adulto , Tomografia/métodos , Topografia da Córnea , Ceratocone/fisiopatologia , Ceratocone/diagnóstico por imagem , Epidemiologia Descritiva , Estudos Transversais , Diagnóstico Precoce
18.
Rev. bras. oftalmol ; 79(6): 420-425, nov.-dez. 2020. tab, graf
Artigo em Português | LILACS | ID: biblio-1156163

RESUMO

Resumo Objetivo: Realizar uma revisão sobre o diagnóstico do ceratocone, com enfoque nos métodos propedêuticos disponíveis. Métodos: Foi realizada uma pesquisa no banco de dados PubMed com as palavras chave: Keratoconus, diagnosis, topography e tomography. Por se tratar de uma revisão, não houve restrição de período para a publicação dos artigos selecionados. Foram também utilizados o manual Prefered Practice Pattern(PPP) da academia americana de oftalmologia, assim como o site "eyewiki.aao.org". Resultados: Dos 641 artigos encontrados no PubMed, assim como os usados como referência para o PPP, 36 foram selecionados por serem considerados mais relevantes para o tema proposto. O site "eyewiki.aao.org" foi utilizado como referência para as figuras. Conclusão: O diagnóstico do ceratocone evoluiu consideravelmente desde quando foi primeiramente descrito. É desejável que seja feito em suas fases precoces devido ao alto potencial de morbidade desta doença. Uma possível integração entre os múltiplos índices diagnósticos, investigação genética, biologia molecular e inteligência artificial é almejado para uma maior acurácia diagnóstica.


Abstract Objective: To Perform a review on the diagnosis of keratoconus, focusing on the available propaedeutic methods. Methods: A search was performed in the PubMed database using the key words: Keratoconus, diagnosis, topography and tomography. As it is a review, there was no restriction regarding the publication period of the selected articles. Furthermore, both the preferred practice pattern(PPP) manual of the American Academy of Ophthalmology, as well as the website "eyewiki.aao.org" were used as reference. The project was submitted to the research ethics committee of the Federal University of São Paulo / UNIFESP / SP 2018 (# 2,568,770). Results: Out of the 641 papers found in PubMed, in adition to those used as a reference for PPP, 36 were selected while considered more relevant to the adopted theme. The website "eyewiki.aao.org" was used as a reference for the images. Conclusion: The diagnosis of keratoconus has evolved considerably since it was first described. It is desirable to diagnose it on the early stages due to its high potential of morbility. A possibility of an integration between the various diagnostic indices, genetic research, molecular biology and artificial intelligence is recommended for greater diagnostic accuracy.


Assuntos
Humanos , Masculino , Adolescente , Pessoa de Meia-Idade , Tomografia/métodos , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Fenômenos Biomecânicos , Dilatação Patológica
19.
Arq. bras. oftalmol ; 83(6): 478-484, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1153081

RESUMO

ABSTRACT Purpose: To investigate the impact of different sizes of steep meridian clear corneal incisions for phacoemul sification on anterior corneal higher-order aberrations. Methods: Medical records of patients who underwent 2.2-mm coaxial micro-incision cataract surgery or 2.75-mm coaxial small-incision cataract surgery were retrospectively reviewed. Only patients with preexisting anterior corneal astigmatism <2.00 diopters (D) and ≥0.50 D who underwent a steep meridian clear corneal incision were included. Primary outcomes were 3rd- to 6th-order anterior corneal higher-order aberrations with an 8-mm pupil. Anterior corneal astigmatism and effective phaco time were evaluated as secondary outcomes. Preoperative and 3-month postoperative outcomes were evaluated. Results: Anterior corneal astigmatism significantly decreased after both procedures; however, there was no significant difference found in surgically induced anterior corneal astigmatism between the two procedures (p=0.146). Although the total higher-order aberrations did not significantly change after both procedures, the group comparison showed a significant difference in surgically induced total higher-order aberrations (a decrease of 0.337 ± 1.156 mm in 2.2-mm coaxial micro-incision cataract surgery and an increase of 0.106 ± 0.521 mm in 2.75-mm coaxial small-incision cataract surgery, p=0.046). Spherical aberrations significantly decreased after 2.2-mm coaxial micro-incision cataract surgery (p=0.001), whereas they did not change significantly after 2.75-mm coaxial small-incision cataract surgery (p=0.564). Coma did not significantly change after either of the procedures. Trefoil did not significantly change after 2.2-mm coaxial micro-incision cataract surgery (p=0.361), whereas it significantly increased after 2.75-mm coaxial small-incision cataract surgery (p<0.001). There was no significant difference shown in effective phaco time between the procedures. A significantly positive correlation was shown between surgically induced anterior corneal astigmatism and coma in 2.75-mm coaxial small-incision cataract surgery (r=0.387, p=0.006). There was no significant correlation found between any surgically induced higher-order aberration changes and effective phaco time. Conclusions: The results showed that 2.2-mm coaxial micro-incision cataract surgery and 2.75-mm coaxial small-incision cataract surgery did not significantly degrade the total higher-order aberrations of the anterior cornea. However, the surgically induced changes in total higher-order aberration showed a significant difference between the two procedures, with a slight reduction after 2.2-mm coaxial micro-incision cataract surgery and a slight increase after 2.75-mm coaxial small-incision cataract surgery. Phaco time and power used during surgery had no impact on corneal aberrations.


RESUMO Objetivo: Investigar o impacto de diferentes ta manhos de incisões em córnea clara com meridiano íngreme para facoemulsificação com aberrações de mais alta ordem da córnea anterior. Métodos: Foram retrospectivamente revisados os prontuários médicos de pacientes que se submeteram a cirurgias de catarata com microincisões coaxiais de 2,2 mm ou com incisões coaxiais pequenas de 2,75 mm. Foram apenas incluídos pacientes com astigmatismo preexistente da córnea anterior <2,00 dioptrias (D) e ³0,50 D, e submetidos a incisões em córnea clara com meridiano íngreme. Os desfechos primários foram aberrações da córnea anterior da 3ª à 6ª ordem com uma pupila de 8 mm. O astigmatismo da córnea anterior e o tempo efetivo de facoemulsificação foram avaliados como desfechos secundários. Os desfechos pré-operatório e pós-operatório aos 3 meses também foram avaliados. Resultados: O astigmatismo da córnea anterior diminuiu significativamente após ambos os procedimentos, mas não se encontrou nenhuma diferença significativa entre os dois procedimentos quanto ao astigmatismo da córnea anterior, induzido pela cirurgia (p=0,146). Embora as aberrações totais de mais alta ordem não se tenham alterado significativamente após ambos procedimentos, a comparação entre os grupos revelou uma diferença significativa nas aberrações totais de mais alta ordem, induzidas pela cirurgia (uma diminuição de 0,337 ± 1,156 mm na cirurgia de catarata por microincisão coaxial de 2,2 mm e um aumento de 0,106 ± 0,521 mm na cirurgia de catarata por incisão coaxial pequena de 2,75 mm; p=0,046). A aberração esférica diminuiu significativamente após cirurgia de catarata por microincisão coaxial de 2,2 mm (p=0,001), mas não se alterou significativamente após cirurgia de catarata por incisão coaxial pequena de 2,75 mm (p=0,564). A aberração de coma não mudou significativamente após qualquer dos procedimentos. O trifólio não se alterou significativamente após cirurgia de catarata por microincisão coaxial de 2,2 mm (p=0,361), mas aumentou significativamente após cirurgia de catarata por incisão coaxial pequena de 2,75 mm (p<0,001). Nenhuma diferença significativa se evidenciou quanto ao tempo efetivo de faco-emulsificação entre os dois procedimentos. Houve uma correlação positiva significativa entre o astigmatismo da córnea anterior, induzido pela cirurgia e a aberração de coma na cirurgia de catarata por incisão coaxial pequena de 2,75 mm (r=0,387, p=0,006). Não foi encontrada correlação significativa entre as alterações nas aberrações totais de mais alta ordem, induzidas pela cirurgia e o tempo efetivo de faco-emulsificação. Conclusões: Nem a cirurgia de catarata por microincisão coaxial de 2,2 mm, nem aquela por incisão coaxial pequena de 2,75 mm degradaram significativamente as aberrações totais de mais alta ordem da córnea anterior. Porém, as alterações nas aberrações totais de mais alta ordem, induzidas pela cirurgia mostraram uma diferença significativa entre os dois procedimentos, com uma ligeira redução na cirurgia de catarata por microincisão coaxial de 2,2 mm e um pequeno aumento na cirurgia de catarata por incisão coaxial pequena de 2,75 mm. O tempo de facoemulsificação e a potência utilizada durante a cirurgia não tiveram impacto nas aberrações corneanas.


Assuntos
Humanos , Astigmatismo , Catarata , Extração de Catarata , Facoemulsificação , Astigmatismo/cirurgia , Astigmatismo/etiologia , Estudos Retrospectivos , Facoemulsificação/efeitos adversos , Córnea/cirurgia , Topografia da Córnea , Implante de Lente Intraocular
20.
Arq. bras. oftalmol ; 83(6): 538-542, Nov.-Dec. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1153084

RESUMO

ABSTRACT Corneal ectasia is one of the main complications of keratorefractive procedures. In this report, we describe a case of corneal ectasia after laser-assisted in situ keratomileusis), which progressed with acute hydrops and aqueous leakage and required a suture for correction.


RESUMO A ectasia corneana é uma das principais complicações das cirurgias refrativas. Neste caso, descrevemos um caso de ectasia corneana induzida por laser-assisted in situ keratomileusis, que evoluiu com hidrópsia aguda e extravasamento de humor aquoso, necessitando de sutura corneana.


Assuntos
Humanos , Córnea/cirurgia , Doenças da Córnea , Doenças da Córnea/etiologia , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Dilatação Patológica , Complicações Pós-Operatórias/etiologia , Suturas/efeitos adversos , Estudos Retrospectivos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...