Resultados 1 - 20 de 154
Filtrar
1.
RFO UPF ; 28(1)20230808. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1511056

RESUMO

Introdução: Mesmo com toda evolução tecnológica desses instrumentos, com o desenvolvimento das limas de liga de níquel-titanio (NiTi) e sistemas mecanizados, as fraturas podem ocorrer durante o preparo químico/mecânico. Existem três abordagens mais regulamente aplicadas para solucionar essa intercorrencia: tentativa de remoção do instrumento com ultrassom, tentativa de ultrapassálo (bypass) ou a obturação do segmento. Objetivo: Relatar um caso da técnica de bypass em instrumento fraturado no canal radicular. Descrição do caso: Paciente, sexo feminino, 47 anos, brasileira, sem condições sistêmicas associadas, foi encaminhada à clínica do Curso de Odontologia da UNIFENAS, Divinópolis, Minas Gerais, Brasil, para resolução de fratura de instrumento no canal mésio- vestibular do primeiro molar superior direito (16). Optou-se pelo tratamento pela técnica de bypass, que envolveu as seguintes etapas: anestesia, abertura, utilização de lima C-Pilot #08 para ultrapassar o instrumento fraturado, odontometria, escalonamento regressivo a partir da lima k#20, desinfecção com hipoclorito de sódio 5%, medicação com hidróxido de cálcio por 21 dias, agitação da substância irrigadora e obturação dos canais radiculares. Conclusão: O bypass ao instrumento é uma técnica conservadora, eficaz e uma solução adequada em casos de fratura de limas endodônticas dentro dos canais radiculares. Essa técnica visa preservar o máximo possível da estrutura dental original, evitando procedimentos mais invasivos.(AU)


Introduction: Even with all technological evolution of these instruments, with the development of nickel-titanium alloy (NiTi) files and mechanized systems, fractures can occur during chemical/mechanical preparation. There are three most commonly applie to resolve this complication: attempting to remove the instrument with ultrasound, attempting to bypass it, or obturating the segment. Objective: To report a case of bypass technique in fractured instrument in the root canal. Case description: A 47-year-old female patient from Brazil, with no associated systemic conditions, was referred to the clinic of the Dentistry Course at UNIFENAS, Divinópolis, Minas Gerais, Brazil, for resolution of an instrument fracture in the mesio-vestibular canal of the right upper first molar (16). Treatment was performed using the bypass technique, which involved the following steps: anesthesia, opening, use of a C-Pilot #08 file to bypass the fractured instrument, odontometry, regressive scaling from the k#20 file, disinfection with 5% sodium hypochlorite, medication with calcium hydroxide for 21 days, agitation of the irrigating substance and root canal filling. Conclusion: Instrument bypass is a conservative, effective technique and an adequate solution in cases of endodontic file fracture within root canals. This technique aims to preserve as much of the original tooth structure as possible, avoiding more invasive procedures.(AU)


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Tratamento do Canal Radicular/instrumentação , Instrumentos Odontológicos , Cavidade Pulpar/diagnóstico por imagem , Falha de Equipamento , Titânio , Radiografia Dentária , Resultado do Tratamento , Níquel
2.
Braz. j. oral sci ; 22: e233938, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1519306

RESUMO

The study aimed to find the incidence and awareness of endodontic instrument separation and its management among dental house officers, postgraduate trainees, demonstrators, consultants, and general dentists. Methods: This online questionnaire-based cross-sectional study was conducted with the approval of the IRB in private and public dental hospitals and dental clinics in Punjab. The authors developed the survey tool, which comprises 24 closed-ended items regarding demographics, the incidence of file separation, and awareness about its management. The data were analyzed using IBM SPSS version 24. The Chi-Square Test was used to compare percentages of categorical variables. Results: Postgraduate trainees experienced the most instrument separations (43.6%), made the most retrieval attempts (49.2%), and experienced the most secondary errors during retrieval (52.1%) (p<0.001). Around four out of ten respondents always informed the patients (39.6%) and department (41.6%) about errors. Manual files (69.8%), stainless steel files (75.8%), and short files (60.4%) were more frequently separated, and the most frequent cause was older fatigue files (57.7%). Manual files were more frequently broken in public dental institutes (p=0.003). Two-thirds of the file separations (72.5%) occurred during cleaning and shaping in the apical third of molars (65.1%), especially in mesiolingual canal (56.4%). Bypass attempt was the most common in symptomatic teeth (47.7%). Conclusions: Preventive approaches such as limiting file reuse and constructing a glide path can reduce the occurrence of file separation. Operators should be familiar with the number of uses of the instrument before fatigue and should be trained through workshops and refresher courses


Assuntos
Humanos , Masculino , Feminino , Preparo de Canal Radicular/instrumentação , Instrumentos Odontológicos , Falha de Equipamento , Endodontistas/estatística & dados numéricos , Paquistão , Tratamento do Canal Radicular/instrumentação , Incidência , Estudos Transversais , Inquéritos e Questionários
5.
J. bras. nefrol ; 42(2): 147-152, Apr.-June 2020. tab
Artigo em Inglês, Português | LILACS | ID: biblio-1134815

RESUMO

ABSTRACT Introduction: The increasing prevalence of chronic kidney disease has increased the demand for arteriovenous fistula (AVF) care. The objective of this study was to assess the relationship between some risk factors for AVF failure (advanced age, female sex, diabetes, obesity, central venous catheter, previous fistula, and hospitalization) and having a Doppler ultrasound performed preoperatively. Methods: A prospective study was performed with 228 dialysis patients from Imperatriz, Maranhão. Half of the sample was randomly selected to receive preoperative Doppler ultrasound and the other half did not, from the period of October 2016 to September 2018. Results: There were 53 total failures corresponding to 23.2% of our sample, which is almost double that of the patients in the clinical group. Considering the failures and risk factors associated with the overall sample, there was a statistically significant association between a central venous catheter on the same side of the AVF with P = 0.04 (Odds Ratio 1.24) and obesity with P = 0.05 (Odds Ratio 1.36), which was not repeated in the Doppler ultrasound group individually. There was no statistically significant difference between the Doppler group and clinical group with respect to the amount of days of previous AVF hospitalization and failure. Conclusions: We concluded that the reduction of failures with an introduction of the Doppler was statistically significant in the overall sample, but establishing a relationship between specific risk factors and failure was only possible with two of the risk factors in the study - obesity and central venous catheter on the same side of the AVF.


RESUMO Introdução: A crescente prevalência de doença renal crônica aumentou a demanda por confecção de fístula arteriovenosa (FAV). O objetivo do presente estudo foi avaliar a relação entre alguns fatores de risco para falha da FAV (idade avançada, sexo feminino, diabetes, obesidade, cateter venoso central, fístula prévia e hospitalização) e a realização de ultrassonografia Doppler no pré-operatório. Métodos: Estudo prospectivo com 228 pacientes em diálise em Imperatriz, MA. Metade da amostra foi randomizada para receber ultrassonografia Doppler no pré-operatório. A outra metade dos pacientes não foi submetido a exame ultrassonográfico. O estudo incluiu pacientes atendidos no período de outubro de 2016 a setembro de 2018. Resultados: Houve 53 falhas (23,2%) em nossa amostra, quase o dobro do número dos pacientes no grupo clínico. Considerando as falhas e os fatores de risco associados à amostra geral, houve associação estatisticamente significativa entre catéter venoso central do mesmo lado da FAV (P = 0,04; Razão de Chances: 1,24) e obesidade (P = 0,05; Razão de Chances: 1,36), o que não foi reproduzido no grupo de ultrassonografia Doppler individualmente. Não houve diferença estatisticamente significativa entre o grupo Doppler e o grupo clínico em relação à quantidade de dias de internação e falha da FAV. Conclusões: A redução de falhas com a introdução do Doppler foi estatisticamente significativa na amostra geral, mas só foi possível estabelecer uma relação entre fatores de risco específicos e falha em dois dos fatores estudados, obesidade e catéter venoso central no mesmo lado da FAV.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Derivação Arteriovenosa Cirúrgica/instrumentação , Fístula Arteriovenosa/complicações , Diálise Renal/efeitos adversos , Ultrassonografia Doppler/métodos , Falência Renal Crônica/terapia , Prevalência , Fatores de Risco , Fístula Arteriovenosa/diagnóstico por imagem , Fatores Etários , Ultrassonografia Doppler/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Cateteres Venosos Centrais/efeitos adversos , Hospitalização/estatística & dados numéricos , Falência Renal Crônica/epidemiologia , Obesidade/epidemiologia
6.
Rev. invest. clín ; 72(3): 144-150, May.-Jun. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1251848

RESUMO

ABSTRACT The emergence of coronavirus disease 19 pandemic and novel research on the high transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has raised controversies over the use of face masks to prevent community transmission. Specific regulations need to be fulfilled to use a face mask as part of the personal protective equipment and high quality of evidence supporting its use to prevent respiratory viral infections, including SARS-CoV-2, is lacking. However, its widespread use is becoming a standard practice in some countries and discrepancies between health authorities on their policy have led to controversy. The aim of this review is to provide an outlook on recent research in this matter and areas of opportunity.


Assuntos
Humanos , Pneumonia Viral/prevenção & controle , Controle de Doenças Transmissíveis/instrumentação , Infecções por Coronavirus/prevenção & controle , Pandemias/prevenção & controle , Betacoronavirus/isolamento & purificação , Máscaras , Pneumonia Viral/transmissão , Dispositivos de Proteção Respiratória , Avaliação de Programas e Projetos de Saúde , Controle de Doenças Transmissíveis/legislação & jurisprudência , Controle de Doenças Transmissíveis/métodos , Infecções por Coronavirus/transmissão , Transmissão de Doença Infecciosa/prevenção & controle , Aerossóis , Síndrome Respiratória Aguda Grave/epidemiologia , Microbiologia do Ar , Desenho de Equipamento , Falha de Equipamento , Vírus da Influenza A Subtipo H1N1 , SARS-CoV-2 , COVID-19
7.
RFO UPF ; 25(1): 112-117, 20200430. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1357743

RESUMO

Objetivo: reportar um caso clínico de ultrapassagem de instrumento endodôntico fraturado em terço médio de canal mésiovestibular de molar superior permanente, utilizando a técnica de instrumentação reciprocante associada à instrumentação convencional manual e ao gel de E.D.T.A. 24%. Relato de caso: paciente do sexo masculino, 24 anos, normossistêmico, compareceu ao consultório odontológico privado com queixa de dor espontânea e encaminhamento para tratamento endodôntico do dente 17. O diagnóstico foi pulpite irreversível sintomática com indicação de tratamento endodôntico primário. A lima principal escolhida foi a Reciproc® R25 M-wire (VDW), que, durante a instrumentação do canal mésiovestibular, sofreu fratura por torção em terço médio, inviabilizando a continuação em direção apical. Considerações finais: a associação da técnica convencional manual das limas Hedströen com a técnica reciprocante de corte reverso da lima Wave One® Gold Primary e o uso do gel de E.D.T.A. 24% permitiram ultrapassagem do fragmento de lima fraturado em terço médio do canal mésiovestibular do dente 17, promovendo selamento hermético, limpeza, modelagem e obturação satisfatórias.(AU)


Objective: to report a clinical case of a fractured endodontic instrument in the middle third of the permanent maxillary molar maxillary canal using the technique instrumentation reciprocation with technique to conventional manual instrumentation and the E.D.T.A. 24% gel. Case report: a 24-yearold normosystemic male patient came to the private dental office complaining of spontaneous pain and referred for endodontic treatment of tooth 17. The diagnosis was irreversible symptomatic pulpitis with indication for primary endodontic treatment. The main file chosen was the Reciproc® R25 M-wire (VDW), which during the instrumentation of the mesiobuccal canal suffered torsional fracture in the middle third, preventing continuity in the apical direction. Final considerations: the association of the conventional manual Hedströen file technique with the reciprocal reverse cutting technique of the Wave One® Gold Primary file and the use of E.D.T.A. 24% gel allowed the fractured file fragment to be overcome in the middle third of the mesiobuccal canal of tooth 17, promoting hermetic sealing, cleaning, modeling and satisfactory filling. (AU)


Assuntos
Humanos , Masculino , Adulto , Tratamento do Canal Radicular/instrumentação , Instrumentos Odontológicos , Falha de Equipamento , Radiografia Dentária , Cavidade Pulpar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem
8.
Rev. chil. anest ; 49(6): 915-918, 2020. ilus
Artigo em Espanhol | LILACS | ID: biblio-1512360

RESUMO

Arterial catheterization is a common procedure performed for invasive blood pressure as well as cardiac output monitoring and blood sampling for analysis. The fracture or embolization of arterial catheters are rare but serious complications, and may cause vascular thrombosis or occlusion. Ultrasound can be used to identify the intravascular fragment, however their removal may be complex. The authors report a case of intra-arterial catheter fracture in the radial artery, confirmed by ultrasound and surgically removed. This case may alert to be aware of this complication when using this invasive method, helping to prevent future complications for patients.


La introducción de un catéter arterial es un procedimiento realizado regularmente para evaluar la presión arterial invasiva, el gasto cardíaco y tomar muestras de sangre para su análisis. La fractura y la embolización de los catéteres arteriales son complicaciones poco frecuentes pero graves y pueden causar trombosis u oclusión de la arteria. La ecografía puede usarse para identificar el fragmento intravascular, pero la extracción puede ser compleja. Presentamos un caso de fractura intravascular del catéter de la arteria radial confirmada por ecografía y extirpada quirúrgicamente. Este caso señala la necesidad de prestar atención a esta complicación cuando se usa el monitoreo invasivo, para evitar complicaciones futuras para los enfermos.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Vasculares , Cateterismo Periférico/efeitos adversos , Remoção de Dispositivo , Corpos Estranhos/cirurgia , Corpos Estranhos/diagnóstico por imagem , Ruptura , Artéria Radial/diagnóstico por imagem , Ultrassonografia Doppler , Falha de Equipamento , Anestésicos/administração & dosagem
10.
Arch. cardiol. Méx ; 89(3): 216-221, jul.-sep. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1149070

RESUMO

Abstract Objective: Anticoagulation is the primary management to prevent venous thromboembolism; inferior vena cava filters (IVCFs) provide a mechanical prophylactic alternative when anticoagulation is contraindicated. The aim of this study was to evaluate in IVCF patients, whether the initiation of anticoagulation therapy is associated with decreased rates of recurrent thrombotic events and device-related complications. Methods: This was a retrospective review of patients that underwent insertion of IVCF. Subjects with IVCF were studied in two groups: those initiated on anticoagulation (A) and without anticoagulation (NA). Variables as indications for IVCF, anticoagulation, recurrence of thrombosis, complications, and reinterventions were examined. Results: From April 2007 to March 2014, 54 patients underwent IVCF placement; (61% of females), with mean age of 54 years (standard deviation ± 19). 28 (52%) were initiated on anticoagulation, during a mean follow-up period of 28 months, five experienced recurrent thrombosis and three were on the A group (p=0.5); when comparing patients that developed post-thrombotic syndrome, seven were in the A group and seven in the NA. Two patients with IVC rupture were in the A group (p=0.5), and the only case of IVCF migration occurred in the A group. 11 (20%) patients died from comorbidities nonrelated to the device or procedure (four in the A cohort). Conclusions: Patients with IVCF on anticoagulation have equivalent rates of thrombotic events and device-related complications than those patients NA.


Resumen Objetivo: La anticoagulación es la terapia de elección para la prevención de tromboembolismo venoso; los filtros de vena cava inferior (FVCI) proveen una alternativa mecánica profiláctica cuando la anticoagulación está contraindicada. El objetivo de este estudio fue evaluar si la terapia anticoagulante se asocia con una tasa menor de eventos trombóticos recurrentes y complicaciones relacionadas con el dispositivo. Métodos: Los pacientes fueron categorizados en dos grupos: Aquellos a los que se les inicio anticoagulación (A) y aquellos que no (NA). Variables tales como indicación de la colocación del filtro, anticoagulación, recurrencia de trombosis y complicaciones fueron examinadas. Resultados: De abril de 2007 a marzo 2014, a 54 pacientes se les coloco un filtro (61% fueron mujeres), con una media de edad de 54 años [Desviación estándar (DE) ±19. Veintiocho (52%) fueron iniciados en anticoagulación y durante un seguimiento de 28 meses, 5 pacientes experimentaron recurrencia de trombosis, 3 en el grupo A (p=0.5). Al comparar los pacientes que desarrollaron síndrome posflebítico, 7 pertenecieron al grupo A y 7 al grupo NA. Dos pacientes con ruptura de vena cava pertenecieron al grupo A (p=0.5) y el único caso de migración del dispositivo ocurrió en el grupo A. Once (20%) pacientes fallecieron debido a comorbilidades no relacionadas con el dispositivo o el procedimiento. Conclusión: Pacientes con FVCI en anticoagulación tienen tasas de eventos trombóticos y complicaciones asociadas a los dispositivos equivalentes a aquellos pacientes sin anticoagulación.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Trombose/epidemiologia , Filtros de Veia Cava/efeitos adversos , Migração de Corpo Estranho/epidemiologia , Anticoagulantes/administração & dosagem , Recidiva , Trombose/etiologia , Incidência , Estudos Retrospectivos , Falha de Equipamento
11.
Int. braz. j. urol ; 45(4): 853-853, July-Aug. 2019.
Artigo em Inglês | LILACS | ID: biblio-1040056

RESUMO

ABSTRACT Introduction Urological surgery is estimated to be the third most common cause of iatrogenic-retained foreign bodies 1. Presentation A 76-year old man was undergoing a transurethral resection of bladder tumor with a 26-Ch continuous flow resectoscope (Karl Storz, Germany). Before starting resection, a detachment of resectoscope sheath tip was noted. The ceramic tip was free-floating in the bladder lumen, and it would not fit within the sheath, making direct extraction using the loop impossible. An attempt was made to break it with a stone punch, but it was unsuccessful due to impossibility of closing it in the branches. Therefore, we decided to fragment the tip with holmium laser (RevoLix®, LISA Laser products, Germany), using an 800-micron, front-firing fiber. Laser device was settled at with 2.5 J energy and 5 Hz frequency. Ceramic appeared very hard, but it was difficult to carry on breaking with this setting because of tip retropulsion. Then, laser setting was switched to lower energy and higher frequency (1 J and 13 Hz). This setting guaranteed the same power of 13 W, but with minimal retropulsion. Results Tip was fragmented against the posterior bladder wall in seven pieces, which were retrieved trough the outer sheath. A total 5.62 kJ were used to fragment it. At the end, superficial lesions of the posterior bladder wall were highlighted. Surgical time was 55 minutes. Patient was discharged home next day without problems. Conclusions Holmium laser fragmentation is a safe and effective approach to remove foreign bodies from the bladder.


Assuntos
Humanos , Masculino , Idoso , Bexiga Urinária/cirurgia , Cerâmica/efeitos da radiação , Falha de Equipamento , Lasers de Estado Sólido/uso terapêutico , Corpos Estranhos/cirurgia , Doses de Radiação , Fatores de Tempo , Neoplasias da Bexiga Urinária/cirurgia , Resultado do Tratamento , Duração da Cirurgia
12.
Clinics ; 74: e1076, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019701

RESUMO

OBJECTIVES: Machinery injuries account for a substantial share of traumatic upper limb injuries (TULIs) affecting young active individuals. This study is based on the hypothesis that there is an important relationship between the improper use of power saws and TULIs. The aim of the study is to assess the prevalence and epidemiology of TULIs caused by power saws and determine the risks related to power saw use. METHODS: A cross-sectional evaluation of medical records from a two-year period was performed. Patients sustaining TULIs related to power saws were analyzed. Data on the epidemiology, site of injury, mechanism of trauma, technical specifications of the tool, cutting material, personal protective equipment, time lost and return to work were obtained. RESULTS: A database search retrieved 193 TULI records, of which 104 were related to power saws. The majority of patients were male (102/104; 98.1%), right-handed (97/104; 93.3%), and manual workers (46/104; 44.2%), with an average age of 46.8 years. The thumb was the most frequently injured site (32/93; 34.4%). Most of the injuries were caused by manual saws (85/104; 81.7%), and masonry saws accounted for 68.2% (58/85) of the cases. Masonry saws improperly used for woodwork resulted in 86.2% (50/58) of the injuries. TULI caused by masonry saws was 5 times higher in manual workers than in other patients. In addition, masonry saws had a risk of kickback 15 times higher than that of other saws, and the risk of injury increased by 5.25 times when the saws were used improperly for wood cutting. CONCLUSIONS: The profile of TULIs related to power saws was demonstrated and was mainly associated with manual saws operated by manual workers that inappropriately used masonry saws for woodworking.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Falha de Equipamento/estatística & dados numéricos , Traumatismos do Antebraço/etiologia , Traumatismos da Mão/etiologia , Brasil/epidemiologia , Acidentes de Trabalho/estatística & dados numéricos , Estudos Transversais , Fatores de Risco , Traumatismos do Antebraço/epidemiologia , Traumatismos da Mão/epidemiologia
13.
Arq. bras. oftalmol ; 81(6): 514-516, Nov.-Dec. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-973851

RESUMO

ABSTRACT Although minimally invasive glaucoma surgery using different types of implants is a promising strategy for treating glaucoma, potential long-term complications require further evaluation. Here, we report a case of the anterior chamber displacement of a Xen implant due to a maneuver aimed at correcting a dysfunctional and bent subconjunctival implant.


RESUMO Embora a cirurgia de glaucoma minimamente in vasiva, que usa diferentes tipos de implantes, seja uma estratégia promissora para o tratamento do glaucoma, as possíveis complicações a longo prazo exigem uma avaliação mais aprofundada. Aqui, relatamos um caso de deslocamento da câmara anterior de um implante Xen devido a uma manobra que visa corrigir um implante subconjuntival disfuncional e dobrado.


Assuntos
Humanos , Masculino , Idoso , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Oftalmológicos/métodos , Glaucoma de Ângulo Aberto/cirurgia , Implantes para Drenagem de Glaucoma , Stents , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Falha de Equipamento , Câmara Anterior/cirurgia
15.
Licere (Online) ; 21(3): 272-298, set.2018. ilus
Artigo em Português | LILACS | ID: biblio-967674

RESUMO

Em 2015, São José do Rio Pardo sediou a 59°edição dos Jogos Regionais com um discurso de legado esportivo para a população do município. Essa pesquisa buscou avaliar o legado deixado a partir da manutenção dos equipamentos públicos de lazer esportivo seis meses após o evento mencionado. Trata-se de um estudo qualitativo de campo que cruzou dados de análise documental com visitas in loco aos equipamentos. Ocorreram investimentos e melhorias que poderiam sinalizar um legado esportivo efetivo e um incentivo às práticas de lazer. Entretanto, ao visitar os locais, percebe-se que o poder público municipal não desempenhou atividades de manutenção básica. Em alguns casos, como na pista de BMX, acredita-se estar mais próximo do "largado" esportivo devido ao estado de abandono, deterioração e falta de manutenção adequada. Sediar eventos dessa magnitude pode contribuir para o incentivo à prática esportiva, desde que o poder público continue a desenvolver políticas e leis de incentivo voltadas ao setor.


In 2015, São José do Rio Pardo City hosted the 59th Regional Games with a sports legacy address for citizenship. The present research sought to evaluate the legacy left from the maintenance of public sports leisure equipment six months after the event mentioned. This is a qualitative field study that crossed documentary analysis data with on-site visits to the equipment. The investments and improvements made could signal a sporting legacy and an incentive to leisure practices. However, when visiting the sites, it is noticed that the municipal public power did not perform basic maintenance activities. Some places are closer to "sportive abandonment" and deterioration due public neglect. Here we can mention the BMX racing track, for example. To host events of the Regional Games magnitude can contribute to the incentive to sports practice as long as the public power continues to develop policies and incentive rules aimed at the sector.


Assuntos
Humanos , Jogos e Brinquedos , Política Pública , Manutenção de Equipamento , Administração Municipal , Equipamentos Esportivos , Falha de Equipamento , Jogos Recreativos , Utilização de Equipamentos e Suprimentos , Atividades de Lazer , Governo Local
16.
Rev. bras. enferm ; 71(4): 1832-1840, Jul.-Aug. 2018.
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-958688

RESUMO

ABSTRACT Objectives: To identify equipment failures during handling by nurses and analyze the conduct of the professionals when these failures occur. Methods: Descriptive, exploratory and qualitative study, whose field was the intensive care unit of a public institution, and the participants were day nurses that worked providing direct care to patients. Data were produced in 2014 through systematic observation and interviews and were examined with thick description and content analysis. Results: The outcomes evinced the inadequate functioning of infusion bombs, users' errors related to the design of equipment and problems with batteries of artificial fans. These failures related to the management of equipment in the unit. Final considerations: It is necessary to strengthen the monitoring systems of safety conditions of equipment in intensive nursing care to prevent incidents.


RESUMEN Objetivo: Identificar las fallas de equipos mientras son utilizados por enfermeros, y analizar sus conductas ante tales fallas. Método: Estudio descriptivo-exploratorio, cualitativo, realizado en la Unidad de Terapia Intensiva de una institución pública. Participaron enfermeros de turno diurno, actuantes en la atención directa del paciente. Los datos fueron obtenidos en el año 2014 a través de observación sistemática y entrevista. Posteriormente, fueron sometidos a análisis por descripción densa y de contenido. Resultados: Se evidenció funcionamiento inadecuado de bombas de infusión, errores del usuario relacionados al diseño del equipo, problemas con baterías de ventiladores artificiales. Las fallas identificadas están relacionadas a la gestión de los equipos de la unidad. Consideraciones finales: Es necesario fortalecer los sistemas de vigilancia en las condiciones de seguridad de equipos en el cuidado intensivo de enfermería, a fin de prevenir la ocurrencia de incidentes.


RESUMO Objetivo: Identificar as falhas dos equipamentos durante o seu manejo pelo enfermeiro e analisar suas condutas diante de tais falhas. Método: Pesquisa descritivo-exploratória, qualitativa, cujo campo foi a Unidade de Terapia Intensiva de uma instituição pública, e os participantes, enfermeiros diurnos atuantes na assistência direta ao paciente. Os dados foram produzidos no ano de 2014, por meio de observação sistemática e entrevista, e posteriormente submetidos a análise por descrição densa e de conteúdo. Resultados: Evidenciaram-se o funcionamento inadequado de bombas infusoras, os erros do usuário relacionados ao desenho do equipamento e problemas com baterias de ventiladores artificiais. Essas falhas identificadas têm relação com a gestão dos equipamentos da unidade. Considerações finais: É preciso fortalecer os sistemas de vigilância das condições de segurança dos equipamentos no cuidado intensivo de enfermagem, a fim de se prevenir a ocorrência de incidentes.


Assuntos
Humanos , Erros Médicos/enfermagem , Falha de Equipamento , Segurança do Paciente/normas , Enfermeiras e Enfermeiros/psicologia , Pesquisa Qualitativa , Enfermeiras e Enfermeiros/normas
17.
Rev. SOBECC ; 23(2): 69-76, abr.-jun.2018.
Artigo em Português | BDENF - Enfermagem, LILACS | ID: biblio-909063

RESUMO

Objetivo: Identificar as implicações da não manutenção dos equipamentos hospitalares na qualidade do atendimento cirúrgico. Método: Trata-se de uma pesquisa quantitativa, exploratória, descritiva, observacional, realizada em um hospital filantrópico do interior de Minas Gerais. Aplicou-se a técnica de observação direta e a avaliação de registros de manutenção preventiva e corretiva dos equipamentos cirúrgicos. Resultados: Durante o período de observação, verificou-se que os equipamentos que mais apresentaram falhas durante a cirurgia foram: bisturi elétrico, intensificador e foco cirúrgico. Os dados de funcionalidade e manutenção dos equipamentos foram comparados com recomendações do fabricante e com a literatura científica. Conclusão: A não manutenção dos equipamentos cirúrgicos pode prolongar a recuperação pós-operatória, aumentar a morbidade e a mortalidade e levar a um impacto financeiro desnecessário para a instituição. Espera-se que os resultados deste estudo possam motivar a equipe multiprofissional à realização da manutenção preventiva dos equipamentos antes das cirurgias.


Objective: To identify the implications of non-maintenance of hospital equipment for the quality of surgical care. Method: This is a quantitative, exploratory, descriptive, observational study carried out at a philanthropic hospital in the countryside of Minas Gerais. The technique of direct observation was applied, as well as the evaluation of records related to preventive and corrective maintenance of surgical equipment. Results: During the observation period, the equipment presenting most failures during surgical procedures were: electric scalpel, intensifier, and surgical focus. Equipment functionality and maintenance data were compared with manufacturers' recommendations and the scientific literature. Conclusion: Failure in surgical equipment maintenance can prolong patients' postoperative recovery, increase morbidity and mortality, and lead to unnecessary financial impact for the institution. It is hoped that the results of this study motivate the multiprofessional team to perform preventive maintenance of equipment before surgeries.


Objetivo: Identificar las implicaciones del no mantenimiento de los equipos hospitalarios en la calidad de la atención quirúrgica. Método: Se trata de un estudio observacional, descriptivo, exploratorio y cuantitativo realizado en un hospital filantrópico del interior de Minas Gerais. Se aplicó la técnica de observación directa y la evaluación de registros de mantenimiento preventivo y correctivo de los equipos quirúrgicos. Resultados: Durante el período de observación, se verificó que los equipos que presentaron el mayor número de fallas durante la cirugía fueron: bisturí eléctrico, intensificador y foco quirúrgico. La funcionalidad del equipo y los datos de mantenimiento se compararon con las recomendaciones del fabricante y la literatura científica. Conclusión: La falta de mantenimiento del equipo quirúrgico puede prolongar la recuperación postoperatoria, aumentar la morbilidad y la mortalidad y generar un impacto financiero innecesario para la institución. Se espera que los resultados de este estudio motiven al equipo multiprofesional a realizar el mantenimiento preventivo del equipo antes de las cirugías


Assuntos
Humanos , Calibragem , Manutenção Preventiva , Falha de Equipamento , Equipamentos Cirúrgicos , Estudos de Avaliação como Assunto , Tutoria
19.
J. appl. oral sci ; 26: e20180144, 2018. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-954493

RESUMO

Abstract Objective The aim of this study was to evaluate the influence of torsional preloading on the cyclic flexural fatigue resistance of thermally treated NiTi instruments. Material and Methods Ten new instruments New Hyflex CM (HF 30.06; Coltene/Whaladent Inc.), Typhoon CM (TYP 30.06; Clinician's Choice Dental Products) and Vortex Blue (VB 30.06; Dentsply Tulsa Dental) were chosen, based on geometry and specific characteristics of the manufacturing process. The new instruments of each system were tested in a bench device to determine their fatigue resistance through mean value of number of cycles to failure (Nf) (Control Group - CG). Another group of 10 new HF, TYP and VB instruments were submitted to 20 cycles of torsional straining between 0° and 180° (Experimental Group - EG) and then submitted to fatigue until rupture under the same conditions of the CG. Tested instruments were examined by scanning electron microscopy (SEM). Data were analyzed using one-way analysis of variance and post hoc Tukey's test (α=.05). Results Higher fatigue resistance was accomplished by HF instruments, followed by VB and TYP (p<0.05). During the torsional preloading, the lowest mean torque value was observed for TYP instruments (p<0.05). The torsional preload caused a significant reduction in the Nf values (p<0.05) of about 20%, 39% and 45% for instruments HF, VB and TYP, respectively. Longitudinal cracks, generated during the torsional preloading, were present in VB files, but were not observed in the CM instruments (HF and TYP). Conclusions In conclusion, the flexural fatigue resistance of thermally treated instruments is diminished after cyclic torsional loading.


Assuntos
Titânio/química , Instrumentos Odontológicos/normas , Desenho de Equipamento/métodos , Falha de Equipamento , Torção Mecânica , Níquel/química , Valores de Referência , Rotação , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Maleabilidade , Preparo de Canal Radicular/instrumentação
20.
Rev. bras. anestesiol ; 67(6): 659-662, Nov.-Dec. 2017. graf
Artigo em Inglês | LILACS | ID: biblio-897785

RESUMO

Abstract Objective The aim of this study is to report a case of a clinically significant obstruction during mechanical ventilation caused by the dissection of the wired endotracheal tube's lumen during general anesthesia in a pediatric patient. Case report A 12-years old patient undergoing general anesthesia for open appendectomy was intubated with a wired endotracheal tube and difficult removal of the guide. After starting the mechanical ventilation, there was increased expiratory fraction of CO2 and need for increased inspiratory pressure. Chance of complications with higher incidences were raised and treated unsuccessfully. Finally, during patient reintubation, the dissection of the endotracheal tube lumen was observed, and ventilation was restored to normal. Conclusion Anesthesia involves numerous possible complications. Suspicion and constant vigilance are essential for early diagnosis and treatment of any threat to the individual integrity. This case is relevant for emphasizing a possible very rare complication related to airway, which can quickly cause hypoxia and irreversible damage. Thus, this case contributes to the detection of this complication more frequently.


Resumo Objetivo Relatar um caso de obstrução à ventilação mecânica clinicamente significativa causada por dissecção do lúmen do tubo endotraqueal aramado durante anestesia geral em um paciente pediátrico. Relato Paciente de 12 anos submetido à anestesia geral para apendicectomia aberta foi intubado com tubo endotraqueal aramado e retirada de guia do tubo difícil. Após iniciar a ventilação mecânica houve aumento da fração expiratória de CO2 e necessidade de aumento da pressão inspiratória. Hipóteses de complicações com maiores incidências foram aventadas e tratadas sem sucesso. Finalmente, ao reintubar o doente, foi verificada dissecção do lúmen do tubo endotraqueal e a ventilação foi restaurada à normalidade. Conclusão O ato anestésico envolve inúmeras possíveis complicações. A suspeição e a vigilância constantes são essenciais para diagnosticar e tratar precocemente qualquer ameaça à integridade do indivíduo. O presente caso é relevante por enfatizar uma possível complicação muito incomum relacionada às vias aéreas capaz de causar hipóxia e danos irreversíveis rapidamente. Dessa forma, o caso contribui para que essa intercorrência seja detectada com maior frequência.


Assuntos
Humanos , Masculino , Criança , Falha de Equipamento , Complicações Intraoperatórias/etiologia , Intubação Intratraqueal/instrumentação , Anestesia Geral/instrumentação