1.
J. health med. sci. (Print) ; 8(1): 45-50, ene.-mar. 2022. ilus, graf, tab
Artigo em Inglês | LILACS | ID: biblio-1395758

RESUMO

Radiation absorbed doses to organs outside the radiation therapy treatment beam can be significant and therefore of clinical interest. Two sets of out-of-beam measurements were performed measuring the leak dose and the scattered dose, at 5 points within the accelerator components (accelerator tube and collimator) and at 21 points on the equipment and surroundings based on a positioning scheme. For this purpose, 52 Optically Stimulated Luminescence (OSL) dosimeters were used in a latest generation helical linear accelerator. Of the 200 cGy fired at a cheese-like phantom, 0.332% of the out-of-beam dose contribution was found to come from the leak and 0.784% was transformed into scattering. For these dose values, estimates of the risk of second tumors in long-term survivors indicate a reduced probability of acquiring a second secondary radiation malignancy, based on information from the 1990 BEIR Committee report.


La dosis absorbida de radiación a órganos fuera del haz de tratamiento de radioterapia puede ser significativa y, por lo tanto, de interés clínico. Se realizaron dos sets de mediciones fuera del haz para determinar la dosis de fuga y la dosis dispersa, en 5 puntos dentro de los componentes del acelerador (tubo de aceleración y colimador) y 21 puntos en el equipo y alrededores basado en un esquema de posicionamiento. Para este fin se utilizaron 52 dosímetros de luminiscencia estimulada ópticamente (OSL, Optically Stimulated Luminescence), en un acelerador lineal helicoidal de última generación. De los 200 cGy disparados a un maniquí tipo queso, se encontró que el 0.332% de la contribución de dosis fuera del haz provenía de la fuga y 0.784% se transforma en dispersión. Para estos valores de dosis, las estimaciones del riesgo de segundos tumores en los supervivientes a largo plazo indican una reducida probabilidad de contraer una segunda malignidad por radiación secundaria, según la información del informe del Comité BEIR de 1990.


Assuntos
Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Dosimetria por Luminescência Estimulada Opticamente , Radiometria/instrumentação , Dosimetria Termoluminescente , Calibragem , Luminescência , Medições Luminescentes
2.
J. health med. sci. (Print) ; 7(4): 231-238, oct.-dic. 2021. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1391707

RESUMO

To ensure a reliable verification of a radiation detector, the right parameters for this response verification must be determined and a specific characterization on the detectors of interest must be performed. These were the main pillars of this study, where four Geiger-Müller at the University of Costa Rica's Cyclotron Facilities' main laboratories were studied and characterized using a 137Cs source. First, a verification of the inverse-square law was performed to corroborate the correct measurement by the detectors as the distance from a 137Cs source to the detectors was varied using a new design for a positioner support to ensure repeatability. This verification yielded a potential fit curve with and equation D=670635 x-1.961 (error percentage of 1.95%) and an R2 value of 0.9836. Then, using combinations of copper plates of widths 1.0 mm and 2.0 mm as attenuators between the source and the detectors, the mass attenuation coefficient for copper was obtained only as a reference value for future calibrations of the detectors. The result for this value was 0.040 cm2 /g. The results obtained in this study and the method developed to achieve these results will serve as a base for calibrations of the detectors at these facilities, which will ensure the safety of the patients and personnel in this building.


Para asegurar respuesta correcta de un detector de radiación, se deben determinar los parámetros correctos para esta verificación y debe realizarse una caracterización específica de los detectores de interés. Estos fueron los pilares principales de este estudio, donde se estudiaron y caracterizaron 4 detectores Geiger-Müller en los laboratorios principales del Ciclotrón de la Universidad de Costa Rica utilizando una fuente radiactiva de 137Cs. Primero, se realizó una verificación de la ley del inverso-cuadrado para corroborar la medición correcta de los detectores según se varía la distancia entre la fuente de 137Cs al detector utilizando un diseño nuevo de un soporte posicionador para la fuente que asegura la repetibilidad entre experimentos. Esta verificación resultó en una curva de ajuste potencial de ecuación D=670635x-1,961 (porcentaje de error de 1,95%) y un valor de R2 de 0,9836. Luego, utilizando combinaciones de placas de cobre de espesores 1,0 mm y 2,0 mm como atenuadores entre la fuente y los detectores, se obtuvo el coeficiente de atenuación másico para el cobre como un valor de referencia para futuras calibraciones de los detectores. Este resultado fue de 0,040 cm2/g. Los resultados obtenidos en esta investigación y el método desarrollado para lograr estos resultados servirán como una base para una futura confirmación metrológica calibraciones de los detectores en estos laboratorios, lo cual colaborará con la seguridad y protección radiológica de pacientes y trabajadores en este edificio.


Assuntos
Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Radiometria/instrumentação , Radiometria/métodos , Universidades , Calibragem , Radioisótopos de Césio , Ciclotrons , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Costa Rica
3.
J. health med. sci. (Print) ; 7(3): 177-182, jul.-sept. 2021. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1381661

RESUMO

Radiosurgery is a high-precision technique for delivering, in most cases, a single highly conformal dose to a stereotactically localized target. It can be indicated for small intracranial injury treatment, using either multiple sources of 60Co (γ rays) or high energy photon beams produced by linear accelerators. In order to minimize the impact of inaccurate localization of the target or dose delivery, a rigorous Quality Assurance (QA) program must be enforced, which should include an independent auditing system. This work proposes a simple and reliable postal QA phantom to be used as an independent evaluation. In it two important parameters were verified such as, the dosimetric precision of the planning system, by comparing the absorbed doses measured in the target volume using different dosimeters (ionization chamber, films, thermoluminescent dosimeters and L-alanine dosimeters) all calibrated against a small volume ion chamber. The exact positioning of the target volume was localized using air spaces and small steel spheres to find the appropriate target coordinates. The head phantom and the instruction sheets were extensively tested and sent by mail to selected institutions. The overall results were very encouraging and suggest that the proposed phantom may be used as a postal system as part of an independent QA tool in radiosurgery.


La radiocirugía es una técnica de alta precisión para administrar, en la mayoría de los casos, una sola dosis altamente conformada en un objetivo localizado estereotípicamente. Puede estar indicado para el tratamiento de pequeñas lesiones intracraneales, utilizando múltiples fuentes de 60Co (rayos γ) o haces de fotones de alta energía producidos por aceleradores lineales. Con el fin de minimizar el impacto de la ubicación inexacta de la administración de la meta o de la dosis, se debe aplicar un riguroso programa de control de calidad (QA), que debe incluir un sistema de auditoría independiente. Este documento propone un fantoma postal de control de calidad simple y fiable que se utilizará como evaluación independiente. Se verificó dos parámetros importantes, como la precisión dosimétrica del sistema de planificación, comparando las dosis absorbidas medidas en el volumen objetivo mediante diferentes dosis (cámara de ionización, películas, dosímetros Termoluminiscentes y dosímetros de L-alanina) todos calibrados con una pequeña cámara de iones de volumen. El posicionamiento exacto del volumen objetivo se localizó utilizando espacios aéreos y pequeñas esferas de acero para encontrar las coordenadas de destino adecuadas. El fantoma principal y las hojas de instrucciones fueron ampliamente probados y enviados por correo a instituciones seleccionadas. Los resultados generales fueron muy alentadores y sugieren que el fantoma propuesto puede utilizarse como sistema postal como parte de una herramienta independiente de control de calidad en radiocirugía.


Assuntos
Humanos , Neoplasias Encefálicas/terapia , Malformações Arteriovenosas Intracranianas/terapia , Radiocirurgia/métodos , Serviços Postais , Controle de Qualidade , Radiometria , Radiocirurgia/efeitos adversos
5.
Braz. dent. j ; 30(4): 397-403, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1011558

RESUMO

Abstract This study measured and compared exitance irradiance and power of 4 commercial dental light-curing units (LCU) (Elipar S10, Elipar DeepCure-S, Corded VALO and Bluephase Style) using different types of radiometers. The devices used to analyze the LCU were classified as either handheld analog (Henry Schein, Spring, Demetron 100A, Demetron 100B and Demetron 200), handheld digital (Bluephase 1, Bluephase II, Coltolux, CureRite and Hilux), or laboratory instruments (Thermopile and Integrating Sphere). The laboratory instruments and the Bluephase II radiometer were also used to measure the LCU's power (mW). The LCU's were activated for 20 s (n=5). Data were analyzed using Kruskal-Wallis and Student-Newman-Keuls multiple comparison test (a=0.05). Among the LCU, the laboratory instruments presented different irradiance values, except for Corded VALO. The Coltolux and Hilux radiometers measured greater irradiance values compared to the laboratory instruments for the four LCUs tested. Within a given LCU, handheld analog units measured lower irradiance values, compared to handheld digital and laboratory instruments, except using the Spring radiometer for the Elipar S10 LCU. None of the handheld radiometers were able to measure similar irradiance values compared to laboratory instruments, except for Elipar S10 when comparing Bluephase 1 and Thermopile. Regarding power measurement, Bluephase II always presented the lowest values compared to the laboratory instruments. These findings suggest that the handheld radiometers utilized by practitioners (analog or digital) exhibit a wide range of irradiance values and may show lower outcomes compared to laboratory based instruments.


Resumo Esse estudo mensurou e comparou a irradiância e a energia de quatro fotopolimerizadores comerciais (Elipar S10, Elipar DeepCure-S, Corded VALO e Bluephase Style) utilizando diferentes tipos de radiômetros. Os dispositivos utilizados para analisar os fotopolimerizadores foram classificados em portáteis analógicos (Henry Schein, Spring, Demetron 100A, Demetron 100B e Demetron 200), portáteis digitais (Bluephase 1, Bluephase II, Coltolux, CureRite e Hilux), ou instrumentos laboratoriais (Thermopile e Integrating Sphere). Os instrumentos laboratoriais e o radiômetro Bluephase II também foram utilizados para medir a energia dos fotopolimerizadores (mW). Os fotopolimerizadores foram ativados por 20 s (n=5). Os dados foram analisados utilizando Kruskal-Wallis e teste de Student-Newman-Keuls (a=0,05). Dentre os fotopolimerizadores, os instrumentos laboratoriais apresentaram diferentes valores de irradiância, exceto para o Corded VALO. O Coltolux e o Hilux mensuraram uma irradiância maior comparado aos instrumentos de laboratório para os quatro fotopolimerizadores testados. Para o mesmo fotopolimerizador, os radiômetros analógicos portáteis mensuraram menores valores de irradiância quando comparados aos digitais portáteis ou aos instrumentos laboratoriais, exceto quando utilizado o Spring para o Elipar S10. Nenhuma diferença foi observada entre os instrumentos laboratoriais na irradiância do Corded VALO. Para a medição da energia, nenhuma diferença foi observada usando Thermopile e a Integrating Sphere para o Corded VALO. Para os outros fotopolimerizadores, cada instrumento indicou uma energia diferente. Esses achados sugerem que radiômetros portáteis utilizados pelos cirurgiões-dentistas (analógico ou digital) exibem uma ampla gama de valores de irradiância e podem mostrar medidas inferiores comparados aos instrumentos de laboratório.


Assuntos
Humanos , Radiometria , Luzes de Cura Dentária , Teste de Materiais , Resinas Compostas
6.
J. oral res. (Impresa) ; 8(2): 104-107, abr. 30, 2019. tab
Artigo em Inglês | LILACS | ID: biblio-1145300

RESUMO

Current evidence indicates that the minimum light intensity of photo curing units required to polymerize in a reliable way a composite resin, in increments of 2mm, is 300mW/cm2. The recent introduction of new generations of composite resin materials for large volume increments, partially contrasts with ISO 4049 (2009), calling for the use of light intensity of 1,000mW/cm2. Therefore, it is considered relevant to carry out periodic measurements of the emission intensity of light-curing units of clinical use. The aim of this study was to test the intensity [mW/cm2] of a representative sample of tungsten-halogen and LED photopolymerization units used in private and public health service in different areas of the Valparaíso Region in Chile. This was achieved through the use of dental radiometers, without considering the variables of intensity modification over time (either spontaneously, by undesirable inherent characteristics of the device, or by programs of intensity modification in time), or the density of accumulated power needed. This in vitro diagnostic test, evaluated a sample of 507 units, 107 halogen and 400 LED, for a period of around one month, using two radiometers as measuring instruments. For LED units the Bluephase Meter® radiometer, from Ivoclar-VivadentTM was used, and for halogen units we used the Coltolux® from ColténeTM. As a result, 85% of the LED and halogen units achieved the minimum requirements of intensity needed for the polymerization of conventional dental biomaterials. However, only 25% from the tested units achieved a power density of 1,000mW/cm2.


Assuntos
Humanos , Tecnologia Odontológica/instrumentação , Resinas Compostas/efeitos da radiação , Equipamentos Odontológicos , Radiometria , Chile , Halogênios , Luz
7.
J. health med. sci. (Print) ; 5(1): 7-14, Ene-Mar. 2019. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1151804

RESUMO

En esta investigación se planteó como objetivo la verificación del comportamiento dosimétrico del Sistema de Planificación de Tratamiento (TPS) de Radioterapia mediante las curvas de calibración de Densidades Electrónicas Relativas (DER). Este estudio se realizó en el Hospital de la Sociedad de Lucha Contra el Cáncer (SOLCA) Núcleo Loja, usando un fantoma antropomorfo CIRS 062M y un tomógrafo Toshiba Activion 16. Para determinar la nueva curva de calibración DER se tomaron los valores de densidades electrónicas especificadas en el manual del fantoma y las Unidades Hounsfield de la imagen tomográfica. Se realizó controles de calidad dosimétricos y verificación dosimétrica en tres casos clínicos: tórax, pelvis y cráneo; para realizar las pruebas dosimétricas se utilizó un acelerador CLINAC CX, cámara de ionización PTW tipo Farmer con volumen sensible de 0,6 cm3 y un electrómetro PTW UNIDOS E. Los resultados mostraron que las medidas para cada inserto del fantoma en ningún caso excedieron los límites establecidos de ± 20 UH, para el tomógrafo y el TPS; las pruebas de control de calidad no superaron el límite máximo de desviaciones en el cálculo de dosis absorbida por el TPS y la obtenida por medición de ± 4 % establecida por la IAEA y las verificaciones dosimétricas en tórax, pelvis y cráneo, determinaron que las desviaciones en el cálculo de la dosis absorbida por el TPS y la obtenida por medición no superaban la tolerancia del ± 5 % establecida por la ICRU.


In this research, the aim was to verify the dosimetric behavior of the Radiotherapy Treatment Planning System (TPS) using the Relative Electron Density (DER) calibration curves. This study was carried out at the SOLCA (Society of Fight Against Cancer) hospital in Loja, using an CIRS model 062M anthropomorphic phantom and a Toshiba Activion 16 tomograph. To determine the new DER calibration curve, the values of the electron densities specified in the manual of the phantom and the Hounsfield Units of the tomographic image were taken. Dosimetric quality controls were made in the location of three clinical cases: thorax pelvis and skull; used a CLINAC CX accelerator was used to perform the dosimetric tests, PTW ionization chamber type Farmer with sensitive volume of 0.6 cm3 and a PTW UNIDOS E electrometer. The results showed that the measurements for each insert of the phantom in no case exceeded the established limits of ± 20 UH, for the tomograph and the TPS; the quality control tests did not exceed the maximum limit of deviations in the calculation of dose absorbed by the TPS and the one obtained by measurement of ± 4% established by the IAEA and the clinical planning in the thorax, pelvis and skull, determine that the deviations in the calculation of the dose absorbed by the TPS and that obtained by measurement, they do not exceed the tolerance of ± 5% established by the ICR.


Assuntos
Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Elétrons , Doses de Radiação , Radiometria , Dosagem Radioterapêutica , Densidade Óssea/fisiologia , Imagens de Fantasmas , Equador , Tomografia Computadorizada de Feixe Cônico/métodos
8.
J. health med. sci. (Print) ; 5(1): 67-73, Ene-Mar. 2019. graf, tab
Artigo em Espanhol | LILACS | ID: biblio-1151928

RESUMO

El objetivo de esta investigación fue determinar la relación entre la dosis de radiación recibida y la práctica en intervención médica. Se estudiaron estadísticamente los reportes dosimétricos de profesionales que han laborado en intervencionismo con un Arco en C en el Hospital José Carrasco Arteaga de la ciudad de Cuenca, Ecuador. Estos informes se basan en lecturas bimensuales de los dosímetros TLD utilizados por el personal para seguridad radiológica. En total, se analizaron 124 personas que trabajaron en el período de noviembre de 2013 a marzo de 2018, es decir, 24 informes. La dosis promedio anual para las enfermeras de quirófanos es de 1,32 mSv, 1,59 mSv para el personal de Urología, 1,74 mSv para el personal de Gastroenterología, 1,78 mSv para el personal de Hemodinamia y 2,33 mSv para el personal de Traumatología. Se concluyó que la dosis promedio para cada práctica no excede la dosis de restricción de 1/3 de la dosis permitida para trabajadores ocupacionalmente expuestos. Intervencionismo en Traumatología resulta ser la práctica con mayor dosis recibida y la más baja perteneció al personal de Enfermería de Quirófanos. Estos resultados son de gran utilidad para saber qué nivel va acorde con cada práctica médica.


The objective of this research was to determine the relationship between the radiation dose received and the practice in medical intervention. The dosimetric reports of professionals who have worked in intervention with a C-Arm at the José Carrasco Arteaga Hospital in the city of Cuenca, Ecuador, were studied statistically. These reports are based on bi-monthly readings of the TLD dosimeters used by the staff for radiological safety. In total, 124 professionals who worked in the period from November 2013 to March 2018 were analyzed, that is, 24 reports. The average annual dose for operating room nurses is 1.32 mSv, 1.59 mSv for urology staff, 1.74 mSv for gastroenterology staff, 1.78 mSv for hemodynamic staff and 2.33 mSv for trauma staff. It is concluded that the average dose for each practice does not exceed the restriction dose of 1/3 of the dose allowed for occupationally exposed workers. Traumatology is the practice with the highest dose received and the lowest belongs to the operating room nursing staff. These results are very useful to know which level is consistent with each medical practice.


Assuntos
Humanos , Masculino , Feminino , Proteção Radiológica/métodos , Radiometria/métodos , Doses de Radiação , Radiologia Intervencionista/tendências , Pessoal de Saúde , Equador , Relatório de Pesquisa , Dosímetros de Radiação/normas
9.
Clinics ; 74: e835, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1011902

RESUMO

The efficacy and toxicity of radionuclide therapy are believed to be directly related to the radiation doses received by target tissues; however, nuclear medicine therapy continues to be based primarily on the administration of empirical activities to patients and less frequently on the use of internal dosimetry for individual therapeutic planning. This review aimed to critically describe the techniques and clinical evidence of dosimetry as a tool for therapeutic planning and the main limitations to its implementation in clinical practice. The present article is a nonsystematic review of voxel-based dosimetry. Clinical evidence pointing to a correlation between the radiation dose and therapeutic response in various diseases, such as thyroid carcinoma, neuroendocrine tumors and prostate cancer, is reviewed. Its limitations include technical aspects related to image acquisition and processing and the lack of randomized clinical trials demonstrating the impact of dosimetry on patient therapy. A more widespread use of dosimetry in therapeutic planning involves the development of user-friendly dosimetric protocols and confirmation that dose estimation implies good efficacy and low treatment-related toxicity.


Assuntos
Humanos , Radioisótopos/administração & dosagem , Radiometria/métodos , Radioterapia/métodos , Cintilografia/métodos , Fatores de Tempo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia por Emissão de Pósitrons/métodos
10.
Braz. J. Pharm. Sci. (Online) ; 53(1): e16092, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839463

RESUMO

ABSTRACT The aim of this study was to create and test a new mice 3D-voxel phantom named DM_BRA for mice and human first-estimation radiopharmaceutical dosimetry. Previously, the article reviews the state-of-art in animal model development. Images from Digimouse CT database were used in the segmentation and on the generation of the voxelized phantom. Simulations for validation of the DM_BRA model was performed at 0.015, 0.1, 0.5, 1 and 4 MeV photons with heart-source. Specific Absorbed Fractions (SAF) data were compared with literature data. The organ masses of DM_BRA correlated well with existing models based on the same dataset; however, few small organ masses hold significant variations. The SAF data in most simulated cases were statistically equal to a significant level of 0.01 to the reference data.


Assuntos
Alfabetização Digital , Dosimetria/análise , Camundongos/classificação , Radiometria/métodos
11.
Braz. j. med. biol. res ; 50(3): e5848, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839264

RESUMO

This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current), the radiometric survey (leakage radiation) and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1) and remained stable for long (constant) and short (repeatability) intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer). The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators) for cells and small animal irradiation, especially in early research stages.


Assuntos
Animais , Doses de Radiação , Radiometria/instrumentação , Calibragem , Desenho de Equipamento , Aceleradores de Partículas , Radiometria/métodos , Raios X
12.
Dental press j. orthod. (Impr.) ; 21(4): 66-72, July-Aug. 2016. tab
Artigo em Inglês | LILACS | ID: lil-795062

RESUMO

ABSTRACT Objective: The aim of this study was to compare the equivalent and effective doses of different digital radiographic methods (panoramic, lateral cephalometric and periapical) with cone-beam computed tomography (CBCT). Methods: Precalibrated thermoluminescent dosimeters were placed at 24 locations in an anthropomorphic phantom (Alderson Rando Phantom, Alderson Research Laboratories, New York, NY, USA), representing a medium sized adult. The following devices were tested: Heliodent Plus (Sirona Dental Systems, Bernsheim, Germany), Orthophos XG 5 (Sirona Dental Systems, Bernsheim, Germany) and i-CAT (Imaging Sciences International, Hatfield, PA, USA). The equivalent doses and effective doses were calculated considering the recommendations of the International Commission of Radiological Protection (ICRP) issued in 1990 and 2007. Results: Although the effective dose of the radiographic set corresponded to 17.5% (ICRP 1990) and 47.2% (ICRP 2007) of the CBCT dose, the equivalent doses of skin, bone surface and muscle obtained by the radiographic set were higher when compared to CBCT. However, in some areas, the radiation produced by the orthodontic set was higher due to the complete periapical examination. Conclusion: Considering the optimization principle of radiation protection, i-CAT tomography should be used only in specific and justified circumstances. Additionally, following the ALARA principle, single periapical radiographies covering restricted areas are more suitable than the complete periapical examination.


RESUMO Objetivo: o objetivo deste estudo foi comparar as doses equivalentes e efetivas absorvidas pelo mesmo receptor, quando exposto a diferentes exames radiográficos digitais (panorâmica, telerradiografia lateral e periapicais) e à tomografia computadorizada de feixe cônico (TCFC). Métodos: dosímetros termoluminescentes pré-calibrados foram colocados em 24 locais em um phantom antropomórfico (Alderson Rando Phantom, Laboratórios de Pesquisas de Alderson, New York, NY, EUA), o que representa um adulto de tamanho médio. Os seguintes equipamentos foram avaliados: Heliodent Plus (Sirona Dental Systems, Bernsheim, Alemanha), Orthophos XG 5 (Sirona Dental Systems, Bernsheim, Alemanha) e i-CAT (Imaging Sciences International, Hatfield, PA, EUA). As doses equivalentes e as doses efetivas foram calculadas tendo-se em conta as recomendações da Comissão Internacional de Proteção Radiológica (International Commission on Radiological Protection, ICRP), publicadas em 1990 e 2007. Resultados: embora a dose eficaz do set radiográfico tenha correspondido a 17,5% (ICRP 1990) e 47,2% (ICRP 2007) da dose da TCFC, as doses equivalentes na pele e superfícies ósseas e musculares desse set foram maiores, quando comparadas às da TCFC. Em algumas áreas, a radiação produzida pelo set de radiografias foi maior, devido à radiação do exame periapical completo. Conclusão: considerando-se o princípio da otimização da proteção radiológica, a tomografia computadorizada adquirida no tomógrafo i-CAT deve ser usada apenas em circunstâncias específicas e justificadas. Além disso, seguindo o princípio ALARA, radiografias periapicais unitárias de áreas pré-selecionadas são mais apropriadas do que o exame periapical completo.


Assuntos
Humanos , Doses de Radiação , Radiografia Panorâmica , Radiografia Dentária Digital , Tomografia Computadorizada de Feixe Cônico , Radiometria/instrumentação , Calibragem , Cefalometria
13.
Dental press j. orthod. (Impr.) ; 21(2): 81-87, Mar.-Apr. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-782947

RESUMO

ABSTRACT Objective: Since the color of esthetic brackets should match that of teeth, the aims of this study were to determine the color and translucency of esthetic brackets by means of the clinically relevant use of a spectroradiometer, and to compare the color of brackets with that of a commercial shade guide. Methods: The color of central and tie-wing regions of four plastic and four ceramic brackets was measured according to the CIE L*a*b* color scale over white and black backgrounds. Brackets were classified into five groups based on their composition. The color of Vitapan Classical Shade Guide tabs was also measured. Translucency parameter (TP) and contrast ratio (CR) were calculated to determine translucency. Results: Color differences between brackets and the shade guide tabs were 10.4 - 34.5 ∆E*ab units. TP and CR values for the central region were 16.4 - 27.7 and 0.38 - 0.58, whereas for the tie-wings they were 24.0 - 39.9 and 0.25 - 0.45, respectively. The color coordinates, TP and CR values were significantly influenced by bracket composition and brand (p < 0.05). Conclusions: Esthetic brackets investigated herein showed unacceptable color differences (∆E*ab > 5.5) compared with the shade guide tabs. Differences in the translucency of brackets by brand were within the visually perceptible range (∆CR > 0.07). Therefore, brackets showing the best matching performance for each case should be selected considering esthetic and functional demands.


RESUMO Objetivo: considerando-se que a cor dos braquetes estéticos deve corresponder à cor dos dentes, os objetivos do presente estudo foram determinar a cor e a translucidez de braquetes estéticos, por meio do uso clinicamente relevante de um espectroradiômetro, e comparar a cor desses braquetes com a cor de uma escala comercial de cores. Métodos: a cor das regiões central e da aleta de quatro braquetes plásticos e quatro braquetes cerâmicos foi medida segundo o sistema de cores CIE L*a*b*, sobre fundos branco e preto. Os braquetes foram classificados em cinco grupos, de acordo com a sua composição. A cor das peças da escala de cores Vitapan Classical(r) também foi medida. O parâmetro de translucidez (PT) e a razão de contraste (RC) foram calculados para se determinar a translucidez. Resultados: as diferenças de cor entre os braquetes e as peças da escala de cores variaram de 10,4 a 34,5 unidades ∆E*ab. Os valores de PT e RC, respectivamente, variaram de 16,4 a 27,7 e de 0,38 a 0,58 na região central; já para a região das aletas, esses valores variaram de 24,0 a 39,9 e de 0,25 a 0,45. As coordenadas de cor e os valores de PT e RC foram significativamente influenciados pela marca e composição dos braquetes (p < 0,05). Conclusões: os braquetes estéticos investigados nesse estudo demonstraram diferenças de cor inaceitáveis (∆E*ab > 5,5), quando comparados às peças da escala de cores. As diferenças de translucidez entre as marcas de braquetes estavam dentro do limite visualmente perceptível (∆RC > 0,07). Portanto, ao selecionar os braquetes com a melhor correspondência de cor, deve-se levar em consideração as exigências estéticas e funcionais de cada caso.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Braquetes Ortodônticos , Estética Dentária , Plásticos , Radiometria , Cerâmica , Cor
14.
Braz. oral res. (Online) ; 30(1): e80, 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-951980

RESUMO

Abstract Dental trauma in immature permanent teeth can damage pulp vascularization, which leads to necrosis and cessation of apexogenesis. Studies on tissue engineering using stem cells from human exfoliated deciduous teeth (SHEDs) have yielded promising results. Laser phototherapy (LPT) is able to influence the proliferation and differentiation of these cells, which could improve tissue engineering. SHEDs (eighth passage) were seeded into 96-well culture plates (103 cells/well) and were grown in culture medium supplemented with 15% defined fetal bovine serum (FBS) for 12 h. After determining the appropriate nutrition deficiency status (5% FBS), the cells were assigned into four groups: 1) G1 - 15% FBS (positive control); 2) G2 - 5% FBS (negative control); 3) G3 - 5% FBS+LPT 3 J/cm2; and 4) G4 - 5% FBS+LPT 5 J/cm2. For the LPT groups, two laser irradiations at 6 h intervals were performed using a continuous wave InGaAlP diode laser (660 nm, with a spot size of 0.028 cm2, 10 mW) in punctual and contact mode. Cell viability was assessed via an MTT reduction assay immediately after the second laser irradiation (0 h) and 24, 48, and 72 h later. We found that G3 and G4 presented a significantly higher cell growth rate when compared with G2 (p < 0.01). Moreover, G4 exhibited a similar cell growth rate as G1 throughout the entire experiment (p > 0.05). These findings indicate that LPT with 5 J/cm2 can enhance the growth of SHEDs during situations of nutritional deficiency. Therefore, LPT could be a valuable adjunct treatment in tissue engineering when using stem cells derived from the dental pulp of primary teeth.


Assuntos
Humanos , Animais , Bovinos , Células-Tronco/efeitos da radiação , Dente Decíduo/citologia , Terapia com Luz de Baixa Intensidade/métodos , Polpa Dentária/citologia , Desnutrição , Radiometria , Fatores de Tempo , Dente Decíduo/efeitos da radiação , Sobrevivência Celular/efeitos da radiação , Células Cultivadas , Reprodutibilidade dos Testes , Análise de Variância , Meios de Cultura , Engenharia Tecidual , Polpa Dentária/efeitos da radiação , Proliferação de Células/efeitos da radiação
15.
Braz. j. med. biol. res ; 48(10): 895-901, Oct. 2015. tab
Artigo em Inglês | LILACS | ID: lil-761598

RESUMO

According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry.


Assuntos
Humanos , Lesões por Radiação/diagnóstico , Liberação Nociva de Radioativos/estatística & dados numéricos , Radiometria/métodos , Pele/efeitos da radiação , Brasil/epidemiologia , Chile/epidemiologia , Espectroscopia de Ressonância de Spin Eletrônica , Traumatismos dos Dedos/etiologia , Traumatismos da Mão/etiologia , Medições Luminescentes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Lesões por Radiação/epidemiologia
16.
Braz. j. med. biol. res ; 48(10): 908-914, Oct. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-761605

RESUMO

Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates.


Assuntos
Adulto , Humanos , Masculino , Aberrações Cromossômicas/efeitos da radiação , Relação Dose-Resposta à Radiação , Elétrons , Leucócitos Mononucleares/efeitos da radiação , Aceleradores de Partículas , Calibragem/normas , Cultura Primária de Células , Doses de Radiação , Radiometria/métodos
17.
Rev. chil. radiol ; 21(3): 94-99, 2015. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-771668

RESUMO

Because diagnostic and interventional radiology procedures represent one of the main sources of irradiation by ionizing radiation in the population, it has become a priority to become familiar with the quantities and units that account for patient dosimetry. There are countless documents and international recommendations on names, concepts, definitions and areas of application for various quantities and units used in patient dosimetry, in interventional and diagnostic radiology procedures. However, national legislation is not updated in this regard and does not provide, in any of its documents, an updated glossary that enables finding this type of information quickly and precisely. Therefore, this review paper presents in a didactic way and in plain language, the main quantities and units to be used in the dosimetry of patients undergoing diagnostic and interventional radiology procedures.


Debido a que los procedimientos de radiodiagnóstico e intervencionismo representan una de las principales fuentes de irradiación a la población por radiaciones ionizantes, se vuelve prioritario conocer las magnitudes y unidades que dan cuenta de la dosimetría a los pacientes. Existen innumerables documentos y recomendaciones internacionales sobre nombres, conceptos, definiciones y campos de aplicación para diversas magnitudes y unidades utilizadas en la dosimetría de pacientes en procedimientos de radiodiagnóstico e intervencionismo. Sin embargo, la legislación nacional no se encuentra actualizada en este sentido y no contempla en ninguno de sus documentos, un glosario actualizado que permita encontrar en forma rápida y precisa este tipo de información. Por lo anterior, este trabajo de revisión presenta de manera didáctica y en un lenguaje sencillo, las principales magnitudes y unidades que se deben utilizar en la dosimetría de pacientes sometidos a procedimientos de radiodiagnóstico e intervencionismo.


Assuntos
Humanos , Diagnóstico por Imagem/normas , Kerma , Radiografia Intervencionista/normas , Radiometria/normas
18.
São Paulo; s.n; 2015. 73 p. ilus, tab.
Tese em Português | LILACS, Inca | ID: biblio-870256

RESUMO

Objetivos: Os objetivos deste estudo foram avaliar os aspectos dosimétricos do uso do estabilizador bucal em reduzir a dose de irradiação nos tecidos saudáveis em pacientes com câncer de boca e orofaringe submetidos à radioterapia conformada tridimensional (3D) e radioterapia de intensidade modulada do feixe (IMRT) e, analisar a incidência das complicações orais decorrente do tratamento e sua relação com as técnicas de irradiação. Materiais e Métodos: Um total de 53 pacientes com câncer de cavidade oral (n = 38) e orofaringe (n = 15), foram prospectivamente avaliados e alocados em três grupos: Grupo 1 (cavidade oral parte inferior, n = 29), Grupo 2 (cavidade oral parte superior, n = 9) e Grupo 3 (orofaringe, n= 15). Para o planejamento radioterápico e avaliação dosimétrica, o mesmo paciente foi submetido a dois exames de tomografias computadorizadas – um com o uso do dispositivo e o outro sem. Todos os pacientes utilizaram o estabilizador bucal durante a radioterapia e foram acompanhados semanalmente em relação aos efeitos colaterais do tratamento. Resultados: Os planejamentos radioterápicos que usaram o estabilizador bucal tiveram menor dose de irradiação nas estruturas saudáveis quando comparado com os planejamentos sem o estabilizador bucal em todos os grupos, principalmente na técnica IMRT. As glândulas parótidas contralaterais e os ossos gnáticos foram as estruturas saudáveis mais poupadas da dose de irradiação. A mucosite foi a complicação oral mais frequente durante a RT...


Objetive: The aims of this study were to evaluate the dosimetric features of intraoral stent in reducing the radiation dose in healthy tissue in patients with oral and oropharyngeal cancer undergoing three-dimensional conformal radiotherapy (3D) or intensity-modulated radiotherapy (IMRT) and, to analyze the incidence of oral complications and its relation with radiation techniques. Materials and Methods: A total of fifty-three patients with oral cavity (n = 38) and oropharynx (n = 15) cancer were prospectively evaluated and allocated into three groups: Group 1 (tumor located in lower oral cavity, n = 29), Group 2 (tumor located in upper oral cavity, n = 9) and Group 3 (oropharynx, n = 15). For radiotherapy planning and dosimetric analysis, the same patient underwent two CT scans - one with the use of the stent and the other without it. All patients used the stent during radiotherapy and were followed-up on a weekly basis to verify possible side effects. Results: In all three groups, the radiotherapy planning with intraoral stent showed significant lower irradiation dose in healthy structures when compared to the planning without the stentthis was particularly clear with the use of the IMRT technique. The contralateral parotid gland and jawbones were the healthy tissues better preserved. The most frequent oral complications verified during RT were mucositis. Interestingly, oral ulcerations were seem, in Group 1, only on the floor of mouth, tongue and lower lip, not affecting the upper oral mucosa. In addition, 3D-treated patients experienced more severe acute dysphagia and dysgeusia than IMRT-treated patients...


Assuntos
Humanos , Radiometria , Neoplasias Bucais , Neoplasias Orofaríngeas , Radioterapia Conformacional , Radioterapia de Intensidade Modulada
19.
Acta méd. costarric ; 55(3): 110-117, jul.-sep. 2013. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-700688

RESUMO

La biodosimetría citogenética se aplica en la evaluación médica de las personas involucradas en situaciones radiológicas anormales, con el fin de evaluar las dosis recibidas, el peligro inminente para la salud y aplicar los tratamientos médicos más adecuados. Además, contribuye al esclarecimiento de sucesos cuando existen dudas respecto a los resultados de la dosimetría física por dosímetros defectuosos, no calibrados o ausentes. Es el método más preciso de dosimetría biológica, ya que existe una relación matemática que permite calcular la dosis, establecer el grado de homogenidad de la exposición y, en caso de exposiciones no homogéneas, establecer la fracción del cuerpo irradiada y la dosis que recibió esa fracción mediante la cuantificación del número y tipos de aberraciones cromos¢micas y de micronúcleos y su distribución en los linfocitos de la sangre periférica. Para este análisis se establecen las relaciones dosis-efecto y un sistema automatizado para el cálculo de las dosis de radiación recibidas. Actualmente se está desarrollando un proyecto conjunto Universidad de Costa Rica-Hospital San Juan de Dios, con el objetivo de explorar los efectos cromosómicos de la radiación, en pacientes expuestos por razones el objetivo de explorar los efectos cromosómicos de la radiación, en pacientes expuestos por razones terapéuticas y atendidos en este hospital. De igual modo, se hará la curva de calibración dosis-respuesta in vitro para rayos gama y se validar  mediante la intercomparación con el Laboratorio de Dosimetría Citogenética de Centro para la Protección e Higiene de las Radiaciones de Cuba...


Assuntos
Humanos , Citogenética , Liberação Nociva de Radioativos/classificação , Exposição à Radiação , Radiação Ionizante , Radiobiologia , Radiometria
20.
Radiol. bras ; 45(2): 71-81, mar.-abr. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-624455

RESUMO

OBJETIVO: Apresentar uma ferramenta de análise de dados que pode ser utilizada para proteção de pacientes e trabalhadores em áreas de uso de equipamentos móveis. MATERIAIS E MÉTODOS: Foi desenvolvida uma ferramenta, em planilha ativa Excel®, que utiliza medidas de exposição para gerar um banco de dados de fatores de forma e calcular o kerma no ar ao entorno de um leito. O banco de dados inicial foi coletado com três equipamentos móveis. Um espalhador não antropomórfico foi utilizado, sendo realizadas medidas de exposição em uma malha de (4,2 × 4,2) m², ao passo de 0,3 m. RESULTADOS: A ferramenta calcula o kerma no ar (associado à exposição de pacientes expostos e ao equivalente de dose ambiente) à radiação secundária. Para distâncias inferiores a 60,0 cm, valores acima do limite máximo de equivalente de dose ambiente definido para área livre (0,5 mSv/ano) foram verificados. Os dados coletados a 2,1 m foram sempre inferiores a 12% do referido limite. CONCLUSÃO: A ferramenta é capaz de auxiliar na proteção radiológica de pacientes e trabalhadores, quando associada à coleta de dados adequada, pois possibilita a determinação de áreas livres ao entorno de leitos em áreas onde equipamentos móveis geradores de radiação X são utilizados.


OBJECTIVE: To present a data analysis toolkit that may be utilized with the purpose of radiation protection of hospital inpatients and workers in areas where mobile apparatuses are used. MATERIALS AND METHODS: An Excel® ActiveSheet was utilized to develop a computational toolkit with exposure measurements to generate a database of shape factors and to calculate the air kerma around hospital beds. The initial database included data collected with three mobile apparatuses. A non-anthropomorphic phantom was utilized and exposure measurements were performed on a (4.2 × 4.2) m² mesh-grid at 0.3 m steps. RESULTS: The toolkit calculates the air kerma (associated with patients' radiation exposure and with ambient equivalent dose) under secondary radiation. For distances lower than 60.0 cm, values above the maximum ambient equivalent dose threshold defined for radiation free areas (0.5 mSv/year) were verified. Data collected at 2.1 m have always presented values lower than 12% of that threshold. CONCLUSION: The toolkit can aid in the radiological protection of patients and workers, provided it is combined with appropriate data collection, since it allows the determination of radiation free areas around beds in rooms where mobile X-ray apparatuses are utilized.


Assuntos
Humanos , Kerma , Exposição à Radiação , Proteção Radiológica , Radiologia , Radiometria/normas , Software , Bases de Dados como Assunto , Manual de Segurança Radiológica , Saúde Ocupacional , Segurança do Paciente