Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Rev. argent. cir ; 112(3): 311-316, jun. 2020. graf
Artigo em Espanhol | LILACS | ID: biblio-1279744

RESUMO

RESUMEN La técnica PIPAC se presenta como una variante de tratamiento para los pacientes con carcinomato sis peritoneal que no son candidatos a una resección. Se describen de manera detallada los pasos y el procedimiento quirúrgico para la administración de quimioterapia intraperitoneal presurizada con dispositivo PIPAC.


ABSTRACT Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is a therapeutic option for patients with unresectable peritoneal carcinomatosis. The steps and the surgical technique of the PIPAC technique are thoroughly described.


Assuntos
Tratamento Farmacológico/métodos , Neoplasias Peritoneais/cirurgia , Neoplasias Peritoneais/tratamento farmacológico , Cefuroxima/administração & dosagem , Aerossóis , Laparoscópios , Metronidazol/administração & dosagem
2.
Rev. chil. obstet. ginecol. (En línea) ; 83(4): 352-358, 2018. tab
Artigo em Espanhol | LILACS | ID: biblio-978106

RESUMO

RESUMEN Objetivos: El objetivo del estudio es observar los beneficios de la entrada laparoscópica con trocar para la óptica, tras la insuflación previa con aguja de Veress en punto de Palmer, hasta conseguir una presión intraabdominal de 25 mmHg. Material y método: Estudio prospectivo de 115 cirugías laparoscópicas realizadas con la técnica anteriormente descrita, por el mismo equipo quirúrgico; de julio de 2014 a marzo de 2018, en el Departamento de Ginecología del Hospital General Santa María del Puerto. Resultados: El tiempo medio de las maniobras de acceso fue de 175 segundos. En el 84.3 % de las ocasiones, el acceso a la cavidad abdominal se consiguió en el primer intento. Sólo en dos ocasiones (1.7%), fue necesario cambiar la técnica de acceso. No se objetivó ninguna complicación o efecto adverso en el 96.5% de las cirugías. En dos pacientes (1.7%) se produjo un enfisema subcutáneo, en una ocasión un enfisema epiploico (0.9%) y en una paciente (0.9%), se objetivó una ligera intolerancia anestésica durante la realización del neumoperitoneo. No se registró durante el estudio ninguna complicación mayor asociada a las maniobras de acceso. Conclusiones: La entrada con presiones altas intraabdominales tras insuflación con aguja de Veress en punto de Palmer, es una técnica segura y reproducible para evitar complicaciones mayores, durante las maniobras de acceso a cavidad abdominal. Además, esta técnica no produce efectos adversos anestésicos relevantes secundarios a las altas presiones en pacientes sanas, debido al escaso tiempo durante el que se mantienen las mismas.


ABSTRACT Objectives: The aim of the study is to observe the benefits of laparoscopic trocar entry for optics, after previous insufflation with Veress needle at Palmer's point, until an intra-abdominal pressure of 25 mmHg is achieved. Material and method: Prospective study of 115 laparoscopic surgeries performed with the previously described technique, by the same surgical team; from July 2014 to March 2018, in the Department of Gynecology of the Hospital General Santa María del Puerto. Results: The average time of access maneuvers was 175 seconds. In 84.3% of the cases, access to the abdominal cavity was achieved on the first attempt. Only on two occasions (1.7%), it was necessary to change the access technique. No complication or adverse effect was found in 96.5% of the surgeries. Subcutaneous emphysema (1.7%) occurred in two patients, epiploic emphysema (0.9%) and in one patient (0.9%), a slight anesthetic intolerance was observed during the pneumoperitoneum. No major complications associated with the access maneuvers were recorded during the study. Conclusions: The entry with high intra-abdominal pressures after insufflation with Veress needle at Palmer's point, is a safe and reproducible technique to avoid major complications, during maneuvers of access to the abdominal cavity. In addition, this technique does not produce relevant adverse anesthetic effects secondary to high pressures in healthy patients, due to the short time during which they remain.


Assuntos
Humanos , Procedimentos Cirúrgicos Operatórios/estatística & dados numéricos , Instrumentos Cirúrgicos , Laparoscopia/métodos , Doenças do Sistema Digestório/cirurgia , Abdome/cirurgia , Laparotomia/métodos , Agulhas , Estudos Prospectivos , Laparoscópios , Estudo Observacional , Laparotomia/efeitos adversos
3.
Rev. latinoam. enferm. (Online) ; 24: e2830, 2016. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-960989

RESUMO

ABSTRACT Objective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled) and positive control (30 filter paper supports, unsterilized), subject to the same incubation procedures. Results: there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. Conclusion: this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument.


RESUMO Objetivo: avaliar a segurança da esterilização a vapor, do instrumental laparoscópico montado com desafio da contaminação. Método: estudo experimental laboratorial, cujo corpo de prova foram trocarte e pinça laparoscópica. Utilizou-se esporos Geobacillus stearothermophillus ATCC-7953, com população microbiana de 106UFC/suporte de papel filtro, removidos do indicador biológico. Três deles foram introduzidos no interior de cada instrumento, no momento da montagem, sendo esterilizados a vapor saturado sob pressão, 134oC por 5 minutos. Depois da esterilização, o instrumental foi desmontado, e cada suporte de papel filtro foi inoculado em meio de cultura de caseína soja, incubado a 56oC por 21 dias. Não havendo crescimento, foram submetidos a um choque térmico de 80oC, por 20 minutos e reincubados por 72 horas. Tamanho da amostra, 185 pinças e 185 trocartes, com poder de 95%. Os experimentos foram acompanhados dos grupos controle negativo comparativo (5 pinças e 5 trocartes com contaminação desafio, esterilizados desmontados) e positivo (30 suportes de papel filtro, não esterilizados), submetidos aos mesmos procedimentos de incubação. Resultados: não houve nenhum crescimento microbiano nos grupos experimental e controle negativo. Os resultados do controle positivo foram satisfatórios. Conclusão: este estudo forneceu fortes evidências científicas para sustentar a segurança da prática de esterilização a vapor do instrumental laparoscópico montado.


RESUMEN Objetivo: evaluar la seguridad de la esterilización a través de vapor, de instrumental laparoscópico previamente montado con desafío de contaminación. Método: estudio experimental en laboratorio, cuyo cuerpo de prueba fueron trócarte y pinza laparoscópica. Se utilizó esporas Geobacillus stearothermophilus ATCC-7953, con población microbiana de 106UFC/soporte de papel filtro, removidos del indicador biológico. Tres de ellos fueron introducidos en el interior de cada instrumento, en el momento del montaje, los que fueron esterilizados a vapor saturado bajo presión, 134oC por 5 minutos. Después de la esterilización, el instrumental fue desmontado y cada soporte de papel filtro fue inoculado en medio de una cultura de caseína y soya, incubado a 56oC por 21 días. No habiendo crecimiento, fueron sometidos a un choque térmico de 80oC, por 20 minutos y nuevamente incubados por 72 horas. La muestra estuvo constituida por 185 pinzas y 185 trócartes, con poder de 95%. Los experimentos fueron acompañados en los grupos: control negativo comparativo (5 pinzas y 5 trócartes con contaminación desafío, esterilizados desmontados) y positivo (30 soportes de papel filtro, no esterilizados), sometidos a los mismos procedimientos de incubación. Resultados: no se encontró crecimiento microbiano en los grupos experimental y control negativo. Los resultados del control positivo fueron satisfactorios. Conclusión: este estudio suministra fuertes evidencias científicas para sustentar que la práctica, de esterilización a vapor del instrumental laparoscópico montado, es segura.


Assuntos
Esterilização/métodos , Laparoscópios/microbiologia , Vapor , Contaminação de Equipamentos
4.
Rev. SOBECC ; 19(4): 201-206, out.-dez. 2014. tab
Artigo em Português | LILACS, BDENF - Enfermagem | ID: lil-745405

RESUMO

Objetivo: Validar o protocolo de limpeza dos instrumentais utilizados em procedimentos videolaparosscópicos. Métodos: Tratou-se de um estudo transversal, realizado em um hospital universitário. Utilizaram-se o teste para detecção de proteínas e adenosina trifosfato a fim de se avaliar a limpeza. Adotou-se como parâmetro de limpeza a recuperação de até 200 unidades relativas de luz (RLU). Resultados: Obteve-se resultado negativo do resíduo de proteína para todos os itens. para o teste de detecção de adenosina trifosfato, a leitura de RLU foi inferior a 200 par os itens de menor complexidade. Enquanto que, para os de maior, ela foi acima do esperado em quatro itens, fato que evidenciou a necessidade de revisão do protocolo. Após isso, os testes de adenosina trifosfato foram repetidos, alcançando redução da leitura de RLU e validação do protocolo. Conclusão: O processamento do material de produtos para a saúde envolve análises crítica e reflexiva, além de conhecimento e poder de decisão...


Assuntos
Estudos de Validação como Assunto , Infecção Hospitalar/prevenção & controle , Instrumentos Cirúrgicos/estatística & dados numéricos , Laparoscópios/estatística & dados numéricos , Reutilização de Equipamento/estatística & dados numéricos , Reutilização de Equipamento/normas
5.
Rev. argent. ultrason ; 12(3): 158-164, sept. 2013. ilus
Artigo em Espanhol | LILACS | ID: lil-734155

RESUMO

Se presenta la experiencia de utilizar el transductor endocavitario introducido por los tres sitios de incisión laparoscópica en cirugías programadas hepato-bilio-pancreáticas.


Assuntos
Abdome/cirurgia , Laparoscopia/métodos , Laparoscopia , Laparoscópios , Ultrassonografia
6.
Gac. méd. Caracas ; 121(2): 122-131, abr.-jun. 2013. tab
Artigo em Espanhol | LILACS | ID: lil-718919

RESUMO

El propósito del trabajo es describir el estado actual de la cirugía mínimamente invasiva (CMI) en Venezuela, con el fin último de incentivar políticas públicas dirigidas a dotar a los hospitales del país con el recurso humano e instrumental necesarios para el desarrollo de procedimientos diagnósticos y terapéuticos destinado a solucionar el problema que representa el cupo quirúrgico en la población de menores recursos económicos. La metodología de investigación está guiada por el paradigma positivista lógico, de enfoque empirico análitico, de raíz epistémica positivista, utilizando lenguaje cuantitativo. Desde el punto de vista heurístico la información procede del Ministerio del Poder Popular para la Salud, Sociedad Venezolana de Cirugía, círculos quirúrgicos, bibliografía nacional e internacional. El estudio de la investigación de campo y del marco teórico referencial nos permite contextualizar el tema y generar conclusiones, así como recomendaciones acordes con el fenómeno de estudio


The purpose of the study is to describe the minimally invasive surgery current state in Venezuela with the last end of motivate public policies toward provide the country's hospitals with the human resource and the necessary instrumental for the development of diagnostic and therapeutic procedures in order to solve the problem of the surgical needs in the population with low economic resources. The research methodology is guide by the logic positivist paradigm, with the empirical analytic focus and using quantitative language. From the heuristic point of view the data comes from the popular health agency. Venezuelan surgical society, surgical circles, national and international bibliograpy. The field research study permits to contextualize the theme and generate preliminary considerations and also recommendations in concordance with the phenomenon in study


Assuntos
Humanos , Artroscópios/provisão & distribuição , Broncoscópios/provisão & distribuição , Equipamentos e Provisões Hospitalares/economia , Equipamentos e Provisões Hospitalares , Laparoscópios/provisão & distribuição , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/tendências , Saúde Pública/tendências , Período Pós-Operatório , Procedimentos Cirúrgicos Ambulatórios/métodos , Robótica/métodos , Saúde Pública/economia
8.
Rev. latinoam. enferm ; 19(2): 370-377, Mar.-Apr. 2011. tab
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: lil-586784

RESUMO

This experimental, comparative, laboratory study evaluated the effectiveness of the sterilization of single-use laparoscopic instruments - SULIs (grasper, dissector, scissors, Veress needle and electrosurgical probe system), after contamination-challenge with bacterial spores and sheep blood, and compared the results of the sterilization tests with those of the equivalent reusable instruments. The cleaning methods used were; ultrasonic washer with pulsatile water jet and enzymatic detergent, manual cleaning, cleaning with pressurized water and rinsing. The SULIs were sterilized with ethylene oxide and the reusable instruments in an autoclave. Sterility tests showed 100 percent negative results for recovery of contaminate microorganisms in both groups. It was concluded that, regarding the sterilization, that it is possible to reprocess SULIs.


O presente estudo, experimental, laboratorial e comparativo, teve como objetivo avaliar a eficácia da esterilidade dos instrumentos laparoscópicos de uso único (ILUU): grasper, dissector, tesoura, agulha de Veress e sistema de sonda de eletrocirurgia, após contaminação desafio com esporos bacterianos e sangue de carneiro, e comparar os resultados dos testes de esterilidade com aqueles dos instrumentos equivalentes "permanentes". Para limpeza, utilizou-se lavadora ultrassônica com jato pulsátil e detergente enzimático, limpeza manual, água sob pressão e enxágue. Os ILUUs foram esterilizados por óxido de etileno, os instrumentos "permanentes" em autoclave. Os testes de esterilidade acusaram resultados 100 por cento negativos para a recuperação dos micro-organismos contaminantes, nos dois grupos. Concluiu-se que, em relação ao alcance da esterilidade, é possível reprocessar ILUU.


Se trata de un estudio, experimental, de laboratorio y comparativo, que evaluó la eficacia de la esterilidad de los instrumentos laparoscópicos de uso único(ILUU): grasper, disector, tijera, aguja de Veres y el sistema de sonda electroquirúrgica, después de "contaminación desafío" con esporas bacterianas y sangre de carnero; los resultados de las pruebas de esterilidad fueron comparados con los de los instrumentos equivalentes "permanentes". Para efectuar la limpieza se utilizó: lavadora ultrasónica con chorro pulsante y detergente enzimático, limpieza manual, agua bajo presión y enjuague. Los ILUU fueron esterilizados con óxido de etileno, los instrumentos "permanentes" en autoclave. Las pruebas de esterilidad mostraron resultados 100 por ciento negativos para la recuperación de los microorganismos contaminantes en los dos grupos. Se concluye que, en relación al alcance de la esterilidad, es posible reprocesar los ILUU.


Assuntos
Esterilização , Infecção Hospitalar , Instrumentos Cirúrgicos , Laparoscópios , Reutilização de Equipamento , Laparoscopia
9.
Int. braz. j. urol ; 36(6): 718-723, Dec. 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-572401

RESUMO

PURPOSE: To confirm the feasibility of the laparoendoscopic Pfannenstiel nephrectomy using conventional laparoscopic instruments. MATERIALS AND METHODS: Since March 2009, laparoscopic nephrectomy through a Pfannenstiel incision has been performed in selected patients in our service. The Veress needle was placed through the umbilicus which allowed carbon dioxide inflow. One 5 mm (or 10 mm) trocar was placed at the umbilicus for the laparoscope, to guide the placement of three trocars over the Pfannenstiel incision. Additional trocars were placed as follows: a 10 mm in the midline, a 10 mm ipsilateral to the kidney to be removed (2 cm away from the middle one), and a 5 mm contralateral to the kidney to be removed (2 cm away from the middle one). The entire procedure was performed using conventional laparoscopic instruments. At the end of the surgery, trocars were removed and all three incisions were united into a single Pfannenstiel incision for specimen retrieval. RESULTS: Five nephrectomies were performed following this technique: one atrophic kidney, one kidney donation, two renal cancers and one bilateral renal atrophy. Median operative time was 100 minutes and median intraoperative blood loss was 100 cc. No intraoperative complications occurred and no patients required blood transfusion. Median length of hospital stay was 1 day (range 1 to 2 days). CONCLUSIONS: The use of the Pfannenstiel incision for laparoscopic nephrectomy seems to be feasible even when using conventional laparoscopic instruments, and can be considered a potential alternative for traditional laparoscopic nephrectomy.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Laparoscopia/instrumentação , Nefrectomia/instrumentação , Estudos de Viabilidade , Laparoscópios , Laparoscopia/métodos , Nefrectomia/métodos , Instrumentos Cirúrgicos , Fatores de Tempo , Resultado do Tratamento
10.
Rev. chil. cir ; 62(3): 288-292, jun. 2010. tab
Artigo em Espanhol | LILACS | ID: lil-562732

RESUMO

Introduction: Natural orifice transluminal endoscopic surgery (NOTES) and Laparoendoscopic Single Site Surgery (LESS) are emerging technologies, which allows to performed surgical procedures avoiding any surgical scars. However there are some problems due to the lack of equipment available for these procedures. The aim of these study is to present our initial experience with the transvaginal nephrectomy NOTES and LESS using standard laparoscopic instruments. Material and Methods: Two female patients (23 and 26 years old) with diagnosis of recurrent urinary tract infection and renal atrophy. A laparoscopic simple nephrectomy with transvaginal NOTES assistance was performed, using one access port for the camera and two abdominal work ports of 10 and 3mm. In a third patient (15 years old) a transumbilical LESS nephrectomy was preformed with the use of standard laparoscopic instruments. Results: Average operative time was 110 min (40-200), with an estimated blood loss of 200 cc. There were no perioperative complications and all patients were discharged 36 hours after surgery. Conclusion: Laparoscopic simple nephrectomy with transvaginal NOTES assistance and LESS are technically feasible with the use of standard laparoscopic instruments. Special access trocars and instruments development for this procedure will allow to performed a pure technique without the use of abdominal incisions.


Introducción: La cirugía endoscópica transluminal a través de orificios naturales (NOTES) y la cirugía laparoendoscópica a través de sitio único (LESS) son tecnologías emergentes, que permiten realizar procedimientos quirúrgicos minimizando el uso de incisiones abdominales. Sin embargo, existen limitaciones respecto al equipamiento disponible para simular la cirugía tradicional. Nuestro objetivo es presentar nuestra experiencia con la técnica de nefrectomía laparoscópica NOTES y LESS con el uso de instrumentos laparoscópicos estándar. Materiales y Métodos: Dos pacientes de sexo femenino de 23 y 26 años, ambas con diagnóstico de infecciones urinarias recurrentes y atrofia renal secundaria. Se les realizó una nefrectomía simple con asistencia de NOTES, utilizando un puerto de trabajo transvaginal para la cámara y dos puertos adicionales de 10 (umbilical) y 3 mm en el abdomen. Un tercer paciente de sexo masculino de 15 a±os de edad, fue operado a través de la técnica LESS por vía transumbilical con el uso de cistoscopio flexible e instrumentos laparoscópicos estándar. Resultados: La media del tiempo operatorio fue de 110 min (40-200), la pérdida sanguínea promedio fue de 133 cc (0-200). No se reportan complicaciones, siendo todos los pacientes dados de alta antes de 36 horas. Conclusión: La nefrectomía laparoscópica con asistencia de NOTES y LESS es técnicamente posible con el uso de instrumentos laparoscópicos estándar. El desarrollo y acceso a trócares y pinzas especiales, permitirá realizar una técnica pura sin el uso de incisiones abdominales.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Infecções Urinárias/cirurgia , Laparoscopia/métodos , Nefrectomia/instrumentação , Nefrectomia/métodos , Endoscopia , Laparoscópios , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Recidiva , Fatores de Tempo , Resultado do Tratamento , Umbigo , Vagina
11.
Rev. bras. ginecol. obstet ; 31(12): 586-591, dez. 2009. tab, ilus
Artigo em Português | LILACS | ID: lil-536736

RESUMO

OBJETIVO: identificar a carga microbiana presente em trocartes reprocessáveis usados nas laparoscopias ginecológicas. MÉTODOS: estudo exploratório descritivo. Um total de 57 trocartes, sendo 30 com 10 mm de diâmetro e 27 com 5 mm, foram recolhidos na sala de operação, imediatamente após o ato cirúrgico, e colocados em recipiente esterilizado onde foram adicionados 250 mL de água destilada estéril. Foi feita agitação dos trocartes para desprendimento de partículas e obtenção do lavado a ser analisado. Realizou-se filtração por meio de membrana de celulose 0,22 µm, colocadas, com pinça esterilizada, em placas ágar sangue. Após incubação, foi feita a análise microbiológica para contagem de unidades formadoras de colônias e posterior identificação do micro-organismo, usando-se técnicas laboratoriais padronizadas. RESULTADOS: a carga microbiana foi recuperada em 47,4 por cento dos trocartes analisados. Destes, 45,6 por cento apresentou crescimento de 1 a 100 unidades formadoras de colônias. Foram identificados 14 tipos de micro-organismos, dentre os quais, Staphylococcus coagulase negativo (28 por cento) e Bacillus sp (21 por cento) foram isolados com maior frequência. Identificou-se também Aeromonas hydrophila, Alcaligenes sp, Candida parapsilosis e enterobactérias. CONCLUSÕES: o estudo demonstrou que o desafio microbiano enfrentado pelos operadores responsáveis pela limpeza e esterilização dos trocartes é baixo quando comparado com o desafio imposto pelos indicadores biológicos; no entanto, não se pode inferir que os riscos de complicações infecciosas sejam mínimos para pacientes.


PURPOSE: to identify the microbial charge present in reusable trocars used in gynecological laparoscopies. METHODS: a descriptive exploratory study. An amount of 57 trocars, 30 with 10 mm of diameter and 27 with 5 mm, have been collected from the surgical unit, immediately after the surgery and placed in a sterilized recipient, in which 250 mL of sterile distilled water was added. Then, the trocars were agitated for the drainage of particles and to obtain a wash-out fluid to be analyzed. After being filtered through 0.22 µm cellulose membrane, the residue was placed on blood agar plates with a sterilized forceps. Following incubation, microbiological analysis has been done to count the number of colonies and further identify the microorganisms, using standard laboratorial techniques. RESULTS: microbial charge was recovered from 47.4 percent of the trocars analyzed. Among those, 45.6 percent presented 1 to 100 growing colonies. Fourteen types of microorganisms have been identified, among which the more frequently isolated were coagulase-negative Staphylococcus (28 percent) and Bacillus sp (21 percent), Aeromonas hydrophila, Alcaligenes sp, Candida parapsilosis, and enterobacteries were also identified. CONCLUSIONS: the study has demonstrated that the microbial challenge faced by the technician responsible for the cleaning and sterilization of trocars is low, as compared to the challenge imposed by biological markers. Nevertheless, it may be not inferred that the risks for infectious complications for patients are minimal.


Assuntos
Feminino , Humanos , Contaminação de Equipamentos , Procedimentos Cirúrgicos em Ginecologia/instrumentação , Laparoscópios/microbiologia , Gravação em Vídeo/instrumentação , Reutilização de Equipamento
12.
Acta cir. bras ; 23(6): 543-550, Nov.-Dec. 2008. graf, tab
Artigo em Inglês | LILACS | ID: lil-496758

RESUMO

PURPOSE: To test the hypothesis that needlescopic cholecystectomies (NC) offer superior outcomes in comparison to common laparoscopic cholecystectomies (LC). METHODS: Sixty consecutive patients with gallbladder disease undergoing either LC or NC were evaluated with respect to differences in operative time, frequency of per-operative incidents, post-operative pain, late postoperative symptoms, length of scars and level of postoperative satisfaction. RESULTS: Mean operative time was similar in both groups. Most of the patients, irrespective of the technique, informed mild postoperative pain. NC patients had lower levels of pain on the 7th postoperative day (PO7) (p<0.01) and decreased need for additional analgesia. Less frequency of epigastric wound pain was observed in NC patients until PO4 (p<0.01). Aesthetic result was far superior after NC (total length of scars less than half after LC). No differences regarding postoperative satisfaction with the operation were observed between the studied groups. CONCLUSIONS: Both techniques were safe and effective, presenting similar operative times and low levels of postoperative pain. Downsizing the ports to 2-3 mm was associated with significantly less frequency of postoperative pain only in the epigastric wound until PO4. Aesthetic outcome of NC was significantly superior to LC, although this advantage did not influence patient level of satisfaction.


OBJETIVO: Testar a hipótese de que colecistectomias agulhascópicas oferecem resultados superiores aos da colecistectomia laparoscópica usual (CL). MÉTODOS: Sessenta pacientes consecutivos com colecistopatia submetidos à CA ou CV foram avaliados quanto ao tempo operatório, freqüência de acidentes peroperatórios, dor pós-operatória, sintomas pós-operatórios tardios, comprimento das cicatrizes e grau de satisfação. RESULTADOS: O tempo operatório médio foi semelhante em ambos os grupos. A maioria dos pacientes, independentemente da técnica, relataram dor pós-operatória leve. Aqueles operados por CA tiveram menores níveis de dor no 7º dia de pós-operatório (PO7) (p<0.01) e menor necessidade de analgesia adicional. Menor freqüência de dor epigástrica foi observada no grupo CA até o PO4 (p<0.01). O resultado estético foi amplamente superior após CA (comprimento total das cicatrizes menor que a metade após CL). Não houve diferença quanto ao grau de satisfação entre os grupos. CONCLUSÕES: As duas técnicas foram seguras e eficazes, apresentando tempos operatórios semelhantes e baixos níveis de dor pós-operatória. A redução dos portais para 2-3 mm associou-se a menor freqüência de dor pós-operatória apenas na incisão epigástrica até o PO4. O resultado estético da agulhascopia foi significantemente superior ao da laparoscopia, apesar desta vantagem não ter influenciado o grau de satisfação dos doentes.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Colecistite/cirurgia , Laparoscópios , Laparoscopia/métodos , Dor Pós-Operatória/prevenção & controle , Colecistectomia Laparoscópica/efeitos adversos , Colecistectomia Laparoscópica/instrumentação , Colecistectomia Laparoscópica/métodos , Complicações Intraoperatórias , Laparoscopia/efeitos adversos , Agulhas , Medição da Dor , Estudos Prospectivos , Resultado do Tratamento
13.
Mediciego ; 14(1)jun. 2008. tab
Artigo em Espanhol | LILACS | ID: lil-532378

RESUMO

Se realizó un estudio observacional descriptivo para analizar el comportamiento de algunas variables relacionadas con las relaparotomías en la Unidad de Cuidados Intensivos en 4142 intervenciones sobre el abdomen realizadas por el servicio de Cirugía General del Hospital General Provincial Docente Capitán Roberto Rodríguez Fernández de Morón en el periodo comprendido entre el 1º de Enero del 2003 al 31 de Diciembre del 2005. Se relaparotomizaron 54 pacientes (índice de reintervención 1.3 por ciento), de estos el 79.63 por ciento fueron inicialmente operados por una cirugía de urgencia, comportándose el sexo masculino con un 61.11 por ciento, siendo el grupo etáreo de 70 años y más el de mayor representatividad. La cirugía sobre el tracto gastrointestinal fue la más asociada a peritonitis post-operatorias. La taquicardia, el dolor abdominal, la fiebre persistente y los disturbios humorales y hallazgos imagenológicos constituyeron los indicadores de relaparotomía de mayor peso para encontrar colecciones intraabdominales en el mayor porciento de los casos a los que se les practicó una reintervención temprana (primeras 72h). El índice de mortalidad global de nuestra serie fue de 51.85 por ciento, prevaleciendo el síndrome de disfunción orgánica múltiple (35.71 por ciento).


An observacional descriptive study was carried out so as to analyze the behavior of some variables related to laparotomies at the Intensive Care Unit, in 4142 abdominal surgeries executed by the General Surgery Service of the General Provincial Docent Hospital "Capitán Roberto Rodríguez Fernández", Morón Municipality during the period comprised between January 1st 2003 and December 31st 2005. 54 patients underwent a laparotomy (re-intervention index 1, 3 percent), out of them, 79, 63 percent were initially operated on because of an emergency surgery, being males the 61.11% and the 70 years old and more etarean group the most representative of all. Surgery on the gastrointestinal tract was the most associated to post-surgical peritonitis. Tachycardia, abdominal pain, nagging fever, humoral disturbances and imaging discoveries constituted the most important laparotomy indicators to identify intra-abdominal collections in the highest percent of the cases to whom, it was practiced an early surgical intervention. (First 71hs). The global mortality index of our series was the 51, 85 percent, prevailing the dysfunction organic multiple syndrome (35, 71percent).


Assuntos
Humanos , Masculino , Feminino , Abdome Agudo/cirurgia , Unidades de Terapia Intensiva , Laparoscópios , Peritonite/complicações , Epidemiologia Descritiva , Estudos Observacionais como Assunto
14.
Rev. chil. obstet. ginecol ; 73(2): 104-109, 2008. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-513828

RESUMO

Objetivo: Analizar la experiencia inicial de entrada umbilical con trocar mínimamente invasivo, Endopath Xcel, bajo visión directa en laparoscopia ginecológica. Método: 20 pacientes ingresadas para cirugía laparoscópica, por patología ginecológica benigna. Pacientes con una media de 54 años, IMC de 32. Cinco pacientes tenían antecedente de cirugía pélvica previa. Se utilizó el trocar blindado Xcel, con cámara endoscópica en su interior. Se identificaron los planos de la pared abdominal a la entrada. Se detuvo la entrada al identificar vasos sanguíneos susceptibles de dañar u órganos adheridos a pared abdominal con posibilidad de perforación. Se utilizó una entrada alternativa. Una vez terminada la cirugía se retiró el trocar, sin suturar la aponeurosis, sólo la piel. Resultados: Sólo en un caso (1 de 20, 5 por ciento) fue necesario detener la inserción del trocar, por identificar la adherencia de intestino delgado a la pared abdominal, susceptible de dañar. Se utilizó el cuadrante superior izquierdo como entrada alternativa. Se soltó el intestino y se realizó adherensiolisis con bisturí ultrasónico exitosamente. Conclusión: El método de inserción del trocar umbilical Xcel con cámara endoscópica acoplada, es un método que permite reducir la posibilidad de complicaciones a la entrada, durante laparoscopia ginecológica.


Objective: To analyze the initial experience of umbilical access with minimally invasive trocar Endopath Xcel, under direct vision in gynecological laparoscopy. Method: 20 patients under laparoscopy surgery for benign gynecological pathology. Media age 54 years old, BMI 32. Five patients had previous surgery. The trocar utilized was Xcel, with endoscopio camera. The planes of the abdominal wall during the entrance were identified. The access was stopped when identifying vessels or organs adhered to the abdominal wall with perforation possibility. An alternative entrance was used. Once finished the surgery the trocar was retired without suturing the muscular fascia, only the skin. Results: Only in one case (1 of 20, 5 percent) it was necessary to stop the trocar insertion, when was identified adhesion of the intestine to the abdominal wall. The left superior quadrant was used like alternative entrance. The adhesions were solved with ultrasonic scalpel. Conclusions: The method of primary access with visual umbilical Xcel trocar connected to the endoscopio camera allows reducing the possibility of complications during the entrance in gynecological laparoscopy procedures.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Doenças dos Genitais Femininos/cirurgia , Laparoscópios , Laparoscopia/métodos , Procedimentos Cirúrgicos em Ginecologia/instrumentação , Complicações Intraoperatórias/prevenção & controle , Endoscópios , Procedimentos Cirúrgicos em Ginecologia/métodos , Cirurgia Assistida por Computador , Resultado do Tratamento
15.
Rev. argent. resid. cir ; 12(2): 55-58, ago. 2007. ilus
Artigo em Espanhol | LILACS | ID: lil-563172

RESUMO

Antecedentes: Dentro de la enseñanza quirúrgica los simuladores laparoscópicos abarcan un papel importante como medio de aprendizaje, capacitación y perfeccionamiento de los futuros cirujanos. Por ésto ha surgido la necesidad de crear un simulador de alta performance y de bajo costo para la educación de un número mayor de profesionales. Objetivos: Desarrollar un simulador para el entrenamiento de cirugía laparascópica. Disminuir el costo de creación del simulador. Evaluar la eficacia del aprendizaje del médico residente en cirugía laparoscópica en este simulador. Lugar de aplicacíón: Sanatorio 9 de Julio, Tucumán. Diseño: Estudio descriptivo, prospectivo de corte transversal. Población: Médicos residentes de distintas especialidades quirúrgicas. Resultados: Se logró el desarrollo de un nuevo simulador de cirugía laparoscópica usando una mini-cámara de video, dismimuyendo ampliamente su costo. Se valoró a 20 médicos residentes, la adquisición de de habilidad y destreza, mediante la realización de maniobras laparascópicas. Conclusión: El uso de simuladores de cirugía laparoscópica está altamente comprobado, pero su costo los hace inaccesibles para el sistema de residencia. El simulador desarrollado por nosotros posee las mismas ventajas pero menor costo por lo que lo hace accesible para todos.


Assuntos
Humanos , Masculino , Feminino , Educação Médica , Internato e Residência/métodos , Laparoscópios , Robótica/educação , Argentina , Redução de Custos , Laparoscopia/tendências
16.
Rev. Fac. Cienc. Méd. (Córdoba) ; 64(2): 10-44, 2007. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-511497

RESUMO

ANTECEDENTES: En el trauma penetrante de abdomen, existe un número de laparotomías innecesarias, con un porcentaje de complicaciones no despreciable. Cuando se identifica lesión del peritoneo, debe ser evaluada la exploración quirúrgica del abdomen. OBJETIVO: Evaluar la penetración del peritoneo, utilizando un método de diagnostico de visión directa. LUGAR DE APLICACIÓN: Hospital de Urgencias de Córdoba. Hospital de trauma. DISEÑO: Se realizó laparoscopia con anestesia local en pacientes con heridas penetrantes de abdomen, que no presentaran evidencias de injuria de órganos intraabdominales en los estudios de imágenes y los cuales se planteaban dudas en el examen físico, para evidenciar lesión del peritoneo. Estudio retrospectivo. POBLACION: Pacientes con trauma penetrante de abdomen, tratados entre mayo de 2004 y enero de 2005, con diagnostico dudoso de violación peritoneal. METODO: Con sedación y anestesia local a nivel umbilical,se coloco un laparoscopio de visión directa, de 5mm y 90°, con el cual se pudo observar todo el peritoneo anterior, los flancos y el diafragma, buscando la herida peritoneal o líquido libre. RESULTADOS: En cuatro pacientes pudo evitarse la laparotomía. Los cuatro restantes se convirtieron a cirugía abierta o videolaparoscopía, de los cuales dos presentaban lesión de víscera hueca, uno hemoperitoneo y otro lesión hepática mínima. No hubo complicaciones en ambos grupos. La estadía del primer grupo fue 13 horas de promedio. CONCLUSIONES: En pacientes seleccionados, la minilaparoscopía resultó útil en disminuir el porcentaje de laparotomías innecesarias y anestesia general y sus complicaciones.


BACKGROUND: There are a number of unnecessary laparotomies in penetrating trauma, with a non worthless percentage of complications. When the peritoneal injury is identified, surgical exploration of the abdomen should be evaluated. OBJECTIVE: Evaluate the penetration of the peritoneum, using a diagnose method with direct vision. SETTING: Hospital de Urgencias de Córdoba. Trauma Hospital. DESIGN: To evidence peritoneum trespassing, laparoscopy was performed with local anaesthesia in patients with penetrating abdominal trauma without signs of abdominal injury in the imaging methods and doubts in the physical examination, in a prospective setting. POPULATION: Patient with penetrating abdominal trauma, treated between May 2004 to January 2005, with doubtful diagnose of peritoneal violation. METHOD: Under sedation and local anaesthesia, a 5 millimetres laparoscope with 90 degrees vision was placed at umbilicus. The anterior abdominal wall, flanks and diaphragm were exanimate, looking for the peritoneal wound or free fluid. RESULTS: Laparotomy could be avoided in four patients. In the four remaining, laparoscopy or conventional surgery was performed. Two presented hollow viscera injury, one hemoperitoneo and the other, minimum liver damage. There were not complications in both groups. The average hospital stay of the first group was 13 hours. CONCLUSIONS: In selected patients, the minilaparoscopy is useful in decreased the percentage of unnecessary laparotomies and general anaesthesia, and its complications.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Laparoscopia/métodos , Peritônio/lesões , Ferimentos Penetrantes/diagnóstico , Serviço Hospitalar de Emergência , Laparoscópios , Seleção de Pacientes , Estudos Prospectivos , Ferimentos Penetrantes/cirurgia
17.
Acta cir. bras ; 21(6): 385-391, Nov.-Dec. 2006. ilus, tab
Artigo em Inglês | LILACS | ID: lil-440745

RESUMO

PURPOSE: To evaluate tests performed to confirm the position of the Veress needle inserted into the left hypochondrium for creation of pneumoperitonium. METHODS: One hundred patients were submitted to laparoscopic procedure with left hypochondrium puncturing. Needle positioning tests were evaluated. The aspiration test was considered positive when organic material was aspirated; the injection test was considered positive when no increased resistance to liquid injection was observed; the recovery test was considered positive when the liquid injected was not recovered; the saline drop test was considered positive when drops of saline in the syringe disappeared quickly; the initial intraperitoneal pressure test was considered positive when pressure levels were £ 8 mmHg. A positive aspiration test indicated iatrogenic injury, whereas a positive result in any of the other tests indicated that the tip of the needle was correctly positioned in the peritoneal cavity. Sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) of the tests were calculated by correlating results considered true positives (a), false positives (b), false negatives (c) and true negatives (d), according to the formulas: SE = [a/(a + c)] x 100; SP = [d/(b + d)] x 100; PPV = [a/(a + b)] x 100; NPV = [d(c + d)] x 100. RESULTS: With regard to the aspiration test, SE and PPV were not applicable, SP was 100 percent and NPV was 100 percent. With regard to the injection test, SE was 0 percent, SP was 100 percent, PPV was inexistent and NPV was 90 percent. Both recovery and saline drop tests yielded the following results: SE was 50 percent, SP was 100 percent, PPV was 100 percent and NPV was 94.7 percent. The initial intraperitoneal pressure test yielded the following results: SE, SP, PPV and NPV were 100 percent. CONCLUSIONS: When inserting the Veress needle into the left hypochondrium, a negative aspiration test guarantees...


OBJETIVO: Avaliar provas de posicionamento da agulha de Veress introduzida no hipocôndrio esquerdo para criação de pneumoperitônio. MÉTODOS: Cem pacientes foram submetidos a laparoscopia com punção no hipocôndrio esquerdo. Provas de posicionamento da agulha foram avaliadas. A prova da aspiração foi considerada positiva quando sugava-se material orgânico; a prova da resistência foi considerada positiva quando apenas pouca pressão à infusão de líquido era observada; a prova de recuperação foi considerada positiva quando o líquido infundido não era recuperado; a prova do gotejamento foi considerada positiva quando gotas depositadas na agulha escoavam rapidamente; a prova da pressão intraperitoneal inicial foi considerada positiva quando os níveis observados eram d" 8 mmHg. Uma prova de aspiração positiva indicava iatrogenia, ao passo que resultados positivos em todas as outras provas indicavam que a ponta da agulha estava adequadamente posicionada na cavidade peritoneal. Foram calculadas a sensibilidade (S), especificidade (E), valores preditivos positivos (VPP) e negativos (VPN) das provas, mediante correlação dos resultados verdadeiro-positivos (a), falso-positivos (b), falso-negativos (c) e verdadeiro-negativos (d), segundo as fórmulas: S = [a/(a + c)] x 100; E = [d/(b + d)] x 100; VPP = [a/(a + b)] x 100; VPN = [d(c + d)] x 100. RESULTADOS: Na prova da aspiração, constatou-se que S e VPP não puderam ser aplicados, e que E = 100 por cento e VPN = 100 por cento. Na prova da resistência, S = 0 por cento, E = 100 por cento, VPP = não existiu e VPN = 90 por cento. Tanto na prova da recuperação como na do gotejamento, S = 50 por cento, E = 100 por cento, VPP = 100 por cento e VPN = 94,7 por cento. Na da pressão inicial, S, E, VPP e VPN = 100 por cento. CONCLUSÕES: Na punção no hipocôndrio esquerdo, um resultado negativo na prova da aspiração garante ausência de iatrogenia; a prova da resistência não indica com certeza o mau posicionamento...


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Abdome/cirurgia , Laparoscopia/métodos , Agulhas , Pneumoperitônio Artificial , Doenças Peritoneais/cirurgia , Punções/métodos , Parede Abdominal , Injeções Intraperitoneais , Laparoscópios , Laparoscopia/normas , Valor Preditivo dos Testes , Pressão , Estudos Prospectivos , Pneumoperitônio Artificial/métodos , Punções/normas
18.
Rev. argent. urol. (1990) ; 70(1): 14-20, ene.-mar. 2005. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-405282

RESUMO

Introducción: La adrenalectomía laparoscópica se ha convertido en una técnica de referencia. El objetivo de este trabajo es mostrar nuestra experiencia inicial en cirugía adrenal laparoscópica, y analizar los resultados quirúrgicos y postquirúrgicos obtenidos. Material y métodos: De agosto del año 2001 a abril del año 2004 inclusive, realizamos en el Servicio de Urología del H.I.B.A 10 cirugías laparoscópicas por patología suprarrenal, por vía transperitoneal. Para el análisis valoramos: datos generales, tiempo operatorio y de internación, complicaciones, necesidad de transfusión sanguínea, evolución postoperatoria, analgesia, anatomía patológica y tiempo de reinicio a la actividad laboral. Indicamos la cirugía en nódulo suprarrenal funcionante, no funcionante mayores de 3 cm. de diámetro, y no funcionante con aumento de tamaño en controles seriados. No incluímos los casos de sospecha de carcinoma suprarrenal. En todos los casos actuó el mismo equipo quirúrgico. Resultados: Fueron operados 10 pacientes, 5 varones y 5 mujeres. Edad promedio: 51,5 años. Presentación: 9 incidentalomas, y 1 hipertenso resistente a la medicación. Tiempo operatorio promedio, 172'. No hubo conversión. La pérdida estimada de sangre fue de 181 ml. No hubo mortalidad. Morbilidad representada por un caso de hemoperitoneo por sangrado del orificio de uno de los trócares, fue reoperado por vía laparoscópica y evolucionó satisfactoriamente. Analgésico: dosis promedio 160 mg. El tiempo promedio de internación fue de 3 días. El peso promedio de los especímenes anátomo-patológicos fue de 91,5 g, y su tamaño promedio fue de 5 cm. Siete pacientes reiniciaron su actividad laboral a las 3 semanas de la cirugía; 3 a las 4 semanas. Conclusión: En nuestra experiencia inicial el abordaje laparoscópico transperitoneal de la glándula suprarrenal constituyó un acceso reproducible y seguro. Los resultados postoperatorios en términos de dolor, tiempo de internación y recuperación postoperatoria resultaron ser auspiciosamente beneficiosos para los pacientes


Assuntos
Adulto , Pessoa de Meia-Idade , Adrenalectomia , Cirurgia Geral , Cirurgia Geral/métodos , Laparoscópios , Neoplasias
19.
Rev. Méd. Clín. Condes ; 15(3): 114-116, jul. 2004. ilus
Artigo em Espanhol | LILACS | ID: lil-425096

RESUMO

El dolor testicular crónico es un problema complejo para el urólogo y el paciente, ya que por la falta de elementos objetivos al examen, habitualmente es sub diagnosticado y puede llegar a constituir un trastorno en la vida diaria de quienes lo padecen. Sólo cuando las múltiples terapias conservadoras han fallado en busca de una solución satisfactoria para su problema, se les ofrece a los pacientes una alternativa quirúrgica. Para estos casos hemos utilizado la cirugía laparoscópica con instrumentos de dos mm de diámetro como una alternativa mínimamente invasiva para realizar una denervación testicular uni o bilateral, con una mínima morbilidad y una alta eficacia. Se efectúa un estudio descriptivo en 11 pacientes con dolor testicular crónico con fracaso en la terapia médica y quirúrgica previa, quienes fueron sometidos a una denervación testicular laparoscópica entre los años 2000 y 2004. Los 11 pacientes presentaron un alivio total del dolor testicular por el cual consultaron. Un paciente diabético, en que se realizó una técnica abierta por tener el abdomen sellado por adherencias, presentó una infección de la herida operatoria, otro paciente presento un hidrocele leve que no requirió tratamiento posterior. La denervación testicular efectuada por mini laparoscopia demostró ser un método simple, seguro y eficaz en el tratamiento del dolor testicular crónico.


Assuntos
Masculino , Humanos , Denervação , Dor/cirurgia , Laparoscopia/métodos , Testículo/inervação , Doença Crônica , Epidemiologia Descritiva , Laparoscópios , Tempo de Internação , Procedimentos Cirúrgicos Minimamente Invasivos , Resultado do Tratamento
20.
Rev. chil. cir ; 55(4): 385-388, ago. 2003. ilus
Artigo em Espanhol | LILACS | ID: lil-393921

RESUMO

El objetivo de este trabajo es reportar la primera colectomía total por vía laparoscópica en un paciente portador de una poliposis adenomatosa familiar. Esta cirugía se enmarca en un Protocolo de Cirugía Laparoscópica Intestinal iniciado el año 1998. Se presenta el caso de una mujer de 27 años en quien se demostró una Poliposis Adenomatosa Familiar (PAF) en una colonoscopía realizada en el marco de un estudio de pesquisa familiar. En ella se verificó la presencia de más de 100 pólipos en el colon, y escasos pólipos rectales. La cirugía se realizó sin dificultades en un tiempo de 300 minutos. La paciente no presentó complicaciones postoperatorias; se realimentó y se dió de alta, al segundo y quinto día postoperatorio, respectivamente. La frecuencia defecatoria es de 4 deposiciones diurnas diarias, sin alterar su calidad de vida. Pensamos que es una cirugía factible de realizar en el marco de un protocolo de trabajo en cirugía laparoscópica intestinal.


Assuntos
Humanos , Feminino , Polipose Adenomatosa do Colo , Colectomia/métodos , Laparoscopia , Custos de Cuidados de Saúde , Laparoscópios/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...