Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
2.
CoDAS ; 32(2): e20190127, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1089612

RESUMO

ABSTRACT Purpose Assess the effect of non-pharmaceutical interventions at work on noise exposure or occupational hearing loss compared to no or alternative interventions. Research strategies Pubmed, Embase, Web of Science, OSHupdate, Cochrane Central and Cumulative Index to Nursing and Allied Health Literature (CINAHL) were searched. Selection criteria Randomized Controlled Trials (RCT), Controlled Before-After studies (CBA) and Interrupted Time-Series studies (ITS) evaluating engineering controls, administrative controls, personal hearing protection devices, and hearing surveillance were included. Case studies of engineering controls were collected. Data analysis Cochrane methods for systematic reviews, including meta-analysis, were followed. Results 29 studies were included. Stricter legislation can reduce noise levels by 4.5 dB(A) (very low-quality evidence). Engineering controls can immediately reduce noise (107 cases). Eleven RCTs and CBA studies (3725 participants) were evaluated through Hearing Protection Devices (HPDs). Training of earplug insertion reduces noise exposure at short term follow-up (moderate quality evidence). Earmuffs might perform better than earplugs in high noise levels but worse in low noise levels (very low-quality evidence). HPDs might reduce hearing loss at very long-term follow-up (very low-quality evidence). Seventeen studies (84028 participants) evaluated hearing loss prevention programs. Better use of HPDs might reduce hearing loss but other components not (very low-quality evidence). Conclusion Hearing loss prevention and interventions modestly reduce noise exposure and hearing loss. Better quality studies and better implementation of noise control measures and HPDs is needed.


RESUMO Objetivo Avaliar o efeito de intervenções no trabalho sobre a exposição ao ruído ou a perda auditiva em comparação com ausência ou intervenções alternativas. Estratégia de pesquisa Buscas em Pubmed, Embase, Web of Science, OSHupdate, Cochrane Central e CINAHL. Critérios de seleção Incluídos ensaios clínicos randomizados (ECR), estudos controlados pré/pós-intervenção (ECPPI) e estudos de séries temporais interrompidas (SIT) avaliando controles de engenharia, administrativos, equipamentos de proteção auditiva (EPAs) e vigilância auditiva. Coletados estudos de caso de engenharia. Análise dos dados Cochrane para revisões sistemáticas, incluindo metanálise. Resultados Foram incluídos 29 estudos. Legislação mais rigorosa pode reduzir níveis de ruído em 4,5 dB(A) (evidência de qualidade muito baixa). Controles de engenharia podem reduzir imediatamente o ruído (107 casos). Onze ECR e ECPPI (3.725 participantes) avaliaram EPAs. Treinamento para inserção do EPA reduz a exposição ao ruído no acompanhamento de curto prazo (evidência de qualidade moderada). Protetores tipo concha podem ter desempenho melhor do que protetores de inserção em níveis altos de ruído, mas piores em níveis mais baixos (evidência de qualidade muito baixa). EPAs podem reduzir a perda auditiva no acompanhamento de muito longo prazo (evidência de qualidade muito baixa). Dezessete estudos (84.028 participantes) avaliaram programas de prevenção de perdas auditivas. Um melhor uso do EPA pode reduzir a perda auditiva, mas outros componentes não (evidência de qualidade muito baixa). Conclusão As intervenções para prevenção da perda auditiva reduzem modestamente a exposição ao ruído e a perda auditiva. Estudos de melhor qualidade e melhor implementação de medidas de controle de ruído e EPA são necessários.


Assuntos
Humanos , Perda Auditiva Provocada por Ruído/prevenção & controle , Ruído Ocupacional/prevenção & controle , Doenças Profissionais/prevenção & controle , Dispositivos de Proteção das Orelhas , Ruído Ocupacional/efeitos adversos , Ruído Ocupacional/legislação & jurisprudência
3.
Rev. salud pública ; 21(2): 195-201, ene.-abr. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1094390

RESUMO

RESUMEN Objetivo Verificar los niveles de atenuación de dos tipos de protectores auditivos de copa bajo condiciones reales de operación. Métodos Se realizó un diseño experimental de medidas repetidas de los niveles de presión sonora al interior y exterior de los protectores auditivos, realizando mediciones de ruido bajo circunstancias habituales de trabajo para operadores de una planta de hidrocarburos. Posteriormente, se determinaron las diferencias entre los niveles de atenuación establecidos por el fabricante, los niveles de atenuación ajustados bajo el método recomendado por NIOSH y los niveles de atenuación obtenidos experimentalmente. Resultados Los valores de atenuación ofrecidos por los fabricantes difieren de los obtenidos experimentalmente, siendo estos últimos, menores en todos los casos del estudio. Los valores de atenuación de los protectores auditivos ajustados bajo el método NIOSH alcanzaron valores más cercanos a los experimentales. Conclusiones La variabilidad entre los valores de atenuación teóricos y experimentales, permiten establecer que las estimaciones de los niveles de atenuación obtenidos en condiciones controladas no consideran aspectos que en condiciones reales de uso afectan la eficiencia del protector auditivo. Este estudio plantea la necesidad de implementar programas integrales de protección auditiva, que permitan considerar variables asociadas a la eficacia del dispositivo en condiciones de uso, a través de la aplicación de pruebas de ajuste o en su defecto a través de la aplicación de los factores de ajuste sugeridos por NIOSH, con el fin de realizar una adecuada selección que permita alcanzar un control efectivo para el ruido.


ABSTRACT Objective To verify the attenuation levels of two types of earmuffs under real operating conditions. Materials and Methods A study with experimental design was carried out to obtain repeated measurements of the sound pressure levels inside and outside hearing protectors in a sample of workers of an oil and gas company working under normal process and exposure conditions. The results allowed determining differences between the attenuation levels established by the manufacturer, the adjusted attenuation levels under the NIOSH method, and the attenuation levels obtained experimentally. Results The attenuation values established by the manufacturers are lower than those ones obtained under actual use conditions in all cases evaluated. Likewise, the attenuation values of the hearing protectors, once adjusted under the NIOSH method, reached values much closer to those obtained experimentally. Conclusions The variability between theoretical attenuation values and experimental values allows concluding that the attenuation levels obtained under controlled laboratory conditions do not take into account certain characteristics that, based on their use, affect the efficiency of the hearing protection device. This study encourages the implementation of comprehensive hearing protection programs that consider variables such as hearing protection effectiveness, under real use conditions, by applying fit tests or other adjustment factors like the one suggested by NIOSH. This would ensure an adequate selection that aims at achieving an effective control of this risk factor.


RESUMO Objetivo Verifique os níveis de atenuação de dois tipos de protetores auriculares em condições reais de operação. Métodos Foi realizado um projeto experimental de medições repetidas dos níveis de pressão sonora dentro e fora dos protetores auditivos, fazendo medições de ruído em condições normais de trabalho para operadores de uma usina de hidrocarbonetos. Posteriormente, foram determinadas as diferenças entre os níveis de atenuação estabelecidos pelo fabricante, os níveis de atenuação ajustados pelo método recomendado pelo NIOSH e os níveis de atenuação obtidos experimentalmente. Resultados Os valores de atenuação oferecidos pelos fabricantes diferem daqueles obtidos experimentalmente, sendo este último menor em todos os casos do estudo. Os valores de atenuação dos protetores auditivos ajustados pelo método NIOSH atingiram valores mais próximos aos experimentais. Conclusões A variabilidade entre os valores de atenuação teórica e experimental permite estabelecer que as estimativas dos níveis de atenuação obtidos em condições controladas não consideram aspectos que, em condições reais de uso, afetam a eficiência do protetor auditivo. Este estudo levanta a necessidade de implementar programas abrangentes de proteção auditiva que permitam considerar variáveis associadas à efetividade do dispositivo em condições de uso, através da aplicação de testes de adaptação ou, na sua falta, através da aplicação de ajuste sugerido pelo NIOSH, a fim de fazer uma seleção adequada para obter um controle eficaz do ruído.(AU)


Assuntos
Humanos , Exposição Ocupacional/normas , Dispositivos de Proteção das Orelhas/normas , Dosímetros de Radiação , Ruído Ocupacional/prevenção & controle , Estudos de Intervenção , Medição de Ruído/métodos
4.
Einstein (Säo Paulo) ; 17(2): eAO4423, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-989779

RESUMO

ABSTRACT Objective To analyze the incidence of otorrhea in the postoperative period of patients submitted to tympanotomy to place ventilation tube, and who did not protect the ear when exposed to water. Methods Open, randomized-controlled trial. Eighty patients submitted to unilateral or bilateral ear grommet tympanostomy were included and divided into two groups: Auricular Protection and Non-Protection to water during bathing and activities in water. Results In the first postoperative month, the Non-Protection Group presented a significant increase in the number of patients with otorrhea and in the incidence. Four patients of the Protection Group (11%) presented at least one episode of otorrhea in this period, representing an incidence of 0.11 (standard deviation ±0.32) episode/month, whereas in the Non-Protection Group there were 12 episodes (33%; p=0.045) and incidence of 0.33 (±0.48; p=0.02). Between the 2nd and the 13th postoperative months, there was no difference between groups. Seven patients in the Protection Group (20%) had at least one episode of otorrhea, representing an incidence of 0.04 (±0.09) episodes/month, while in the Non-Protection Group there were seven episodes (22%; p=0.8) and incidence of 0.05 (±0.1; p=0.8). Conclusion Patients who underwent ear protection when exposed to water had a lower incidence of otorrhea in the first postoperative month than those who did not undergo protection. From the second month, there was no difference between groups.


RESUMO Objetivo Avaliar a incidência de otorreia no período pós-operatório em pacientes submetidos à timpanotomia para colocação de tubo de ventilação e que não realizaram proteção auricular quando expostos à água. Métodos Ensaio clínico controlado, aberto e randomizado. Foram incluídos 80 pacientes submetidos à timpanotomia para colocação de tubo de ventilação unilateral ou bilateral, divididos em dois grupos: Grupo Proteção e Grupo Não Proteção auricular da água durante o banho e as atividades aquáticas. Resultados No primeiro mês pós-operatório, o Grupo Não Proteção apresentou aumento significativo tanto no número de pacientes com otorreia quanto na incidência. Quatro pacientes do Grupo Proteção (11%) apresentaram ao menos um episódio de otorreia neste período, representando incidência de 0,11 (desvio padrão ±0,32) episódio/mês, enquanto no Grupo Não Proteção ocorreram 12 episódios (33%; p=0,045) e incidência de 0,33 (±0,48; p=0,02). Entre o 2º e o 13º meses pós-operatórios, não houve diferença entre os grupos. Sete pacientes do Grupo Proteção (20%) apresentaram ao menos um episódio de otorreia, representando incidência de 0,04 (±0,09) episódios/mês, enquanto no Grupo Não Proteção foram registrados sete episódios (22%; p=0,8) e incidência de 0,05 (±0,1; p=0,8). Conclusão Pacientes que realizaram a proteção auricular quando expostos à água apresentaram menor incidência de otorreia no primeiro mês pós-operatório do que aqueles que não a realizaram. A partir do segundo mês, não houve diferença entre os grupos.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Adulto Jovem , Otite Média Supurativa/etiologia , Otite Média Supurativa/prevenção & controle , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Água/efeitos adversos , Ventilação da Orelha Média/efeitos adversos , Otite Média Supurativa/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Natação , Fatores de Tempo , Banhos/efeitos adversos , Brasil/epidemiologia , Modelos Logísticos , Incidência , Fatores de Risco , Resultado do Tratamento , Estatísticas não Paramétricas , Dispositivos de Proteção das Orelhas
5.
Rev. Fac. Cienc. Méd. (Quito) ; 42(1): 108-113, jun.2017.
Artigo em Espanhol | LILACS | ID: biblio-1005096

RESUMO

Contexto: los efectos de la exposición a la contaminación sonora incluyen síntomas auditivos como hipoacusia, elevación del umbral auditivo, trauma acústico y también no auditivos de tipo psicológico, físico y social. Material y métodos: estudio descriptivo analítico y transversal para determinar la eficacia de la atenuación sonora de los protectores auditivos personalizados en un grupo de 33 pacientes hombres sin alteraciones físicas del conducto auditivo externo, mediante la comparación de las respuestas obtenidas en el oído real libre y sin amplificación (Real-Ear Unaided Response) y con el oído herméticamente ocluido por medio de un tapón de silicona hecho a la medida (Real-Ear Occluded), ante la presencia de un ruido externo estable de banda ancha de 65 dB de intensidad, utilizando para ello un equipo de precisión certificado con normas ISO (Verifit de Audioscan). Resultados: se encontró que existe mayor protección a los decibeles altos con las frecuencias: 2000 Hz, 3000 Hz y 4000 Hz, bajando de 65 a 40 decibeles que traduce una reducción del 61%; no existe diferencia significativa entre ambos oídos, lo cual se explica por las particularidades en las formas anatómicas, profundidad de la inserción y la adecuada colocación de la sonda microfónica. Los valores promedio de atenuación bilateral en dB SPL que se logra en las diferentes frecuencias con tapones personalizados de protección auditiva varían dependiendo de la misma, con 250 Hz es de 9,97 en el oído derecho y 9,36 en el oído izquierdo y con 6000 Hz 15,28 en el oído derecho y 13,64 en el oído izquierdo. Una mayor atenuación se encontró con 3000 Hz (OD: 32,11 OI: 30,69), 2000 Hz (OD: 28,33 OI: 28,47) y 4000 Hz (OD: 27,28 OI: 26,67). Conclusión: el uso de protectores auditivo logra una evidente reducción de los niveles sonoros, sobre todo con frecuencias agudas (primeras) cuyos umbrales se afectan al someterse a elevados niveles de ruido por tiempos prolongados. (AU)


Context: the effects of exposure to noise pollution include auditory symptoms: hearing loss, elevation of the auditory threshold, acoustic trauma and also non-auditory psychological, physical and social. Material and methods: a descriptive, analytical, cross-sectional study, the efficacy of the sound attenuation of the personalized hearing protectors was determined in a group of 33 male patients without physical alterations in the external auditory canal, by means of the comparison of the responses obtained in the ear Real-Ear Unaided Response, and with the ear sealed by means of a custom-made silicone plug (Real-Ear Occluded), in the presence of stable external broadband noise of 65 dB Of intensity, using a precision equipment certified with ISO standards, the Verifit of Audioscan. Results: it was found that there is a greater protection to high decibels with frequencies 2000 Hz, 3000 Hz and 4000 Hz, falling from 65 to 40 decibels, which means a reduction of 61%, there is no significant difference between both ears, Which is explained by the particularities in the anatomical forms, depth of insertion and the proper placement of the microphone probe. The average bilateral attenuation values in dB SPL that is achieved in the different frequencies with personalized ear protection plugs vary depending on the same, with 250 Hz being 9.97 in the right ear and 9.36 in the left ear and with 6000 Hz 15.28 in the right ear and 13.64 in the left ear. Greater attenuation was found with 3000 Hz (OD: 32.11 OI: 30.69), 2000 Hz (OD: 28.33 OI: 28.47) and 4000 Hz (OD: 27.28 OI: 26.67). Conclusion: the use of hearing protectors; Achieves an evident reduction of the sound levels, especially with acute frequencies, which are the first ones whose thresholds are affected when undergoing high levels of noise for prolonged times. Keywords: sound attenuation, hearing protectors, noise induced hearing loss, auditory contamination


Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Otorrinolaringopatias , Limiar Auditivo , Dispositivos de Proteção das Orelhas , Orelha , Otopatias , Perda Auditiva
6.
CoDAS ; 28(2): 99-105, mar.-abr. 2016. tab, graf
Artigo em Português | LILACS | ID: lil-782135

RESUMO

RESUMO Objetivo Avaliar a eficácia da atenuação de um protetor auditivo em uma situação real de trabalho utilizando o método f-Microphone-in-real-ear (f-MIRE). Métodos Participaram 18 indivíduos, de ambos os gêneros (média de idade 47,17±8 anos). No local de trabalho, foi realizada a avaliação do nível pessoal de atenuação do Protetor Auditivo (PA) pelo método Field Microphone-in-Real-Ear (f-MIRE), seguido por orientações sobre a importância do uso do PA, higienização, armazenamento e treinamento para sua colocação efetiva. Resultados As análises mostraram que houve atenuação estatisticamente significante para todos os dados coletados (ruído total, por banda de frequência e dose) quando comparados os níveis de ruído no microfone lapela e no microfone sonda. Na comparação entre os valores de atenuação fornecidos pelo fabricante e os encontrados neste estudo, observou-se valores maiores para o fabricante em todas as bandas de frequência. Não houve diferença para os níveis de ruído nas diferentes atividades e horários avaliados. Conclusão Os achados do presente estudo possibilitaram conhecer o nível pessoal de atenuação do protetor auditivo durante uma situação real de trabalho, que estava dentro dos limites de tolerância. Também foi possível coletar informações sobre o ruído do ambiente em que esses trabalhadores estão expostos, onde observamos situações nas quais esse nível ultrapassava os valores de segurança, sendo assim recomendável o uso do PA. É importante que mais estudos sejam realizados utilizando o método f-MIRE, pois pode ser um aliado para avaliar a eficácia da atenuação do PA no local de trabalho.


ABSTRACT Purpose To evaluate the effectiveness of the attenuation of a hearing protector (HP) in a real work situation using the field-microphone-in-real-ear method (f-MIRE). Methods Eighteen individuals of both genders (mean age of 47.17±8 years) participated in this study. In the workplace, the personal attenuation level of the HP was assessed using the f-MIRE method, followed by orientation about the importance of using the HP, cleaning and storing the device, and training for effective placement. Results The analyses showed a significant statistic attenuation for all of the collected data (total noise, by frequency band and dose) when the noise levels in the lapel microphone and the probe microphone were compared. In the comparison of the attenuation values provided by the manufacturer and those found in this study, we observed higher values for the manufacturer in all frequency bands. No difference was observed for the noise levels in the different activities and times evaluated. Conclusion The findings of this study enabled us to know the personal level of attenuation of the HP during a real work situation, which was within the limits of tolerance. It was also possible to collect information about the environmental noise to which these workers are exposed. We noticed situations where this level exceeded the safety values, and therefore it is recommended the use of the HP. It is important that more studies are conducted using the f-MIRE method, because it may be an ally to assess the effectiveness of the HP attenuation in the workplace.


Assuntos
Humanos , Masculino , Feminino , Adulto , Exposição Ocupacional/prevenção & controle , Dispositivos de Proteção das Orelhas , Ruído Ocupacional/prevenção & controle , Valores de Referência , Monitoramento Ambiental/instrumentação , Local de Trabalho , Desenho de Equipamento , Perda Auditiva Provocada por Ruído/prevenção & controle , Pessoa de Meia-Idade
7.
CoDAS ; 27(6): 514-519, nov.-dez. 2015. tab
Artigo em Inglês | LILACS | ID: lil-770517

RESUMO

ABSTRACT Purpose: To determine the efficacy of hearing protector insertion by comparing attenuation values measured by objective (MIRE) and subjective (REAT) methods in groups with and without training. Methods: The study included 80 male subjects assigned to experimental (with training) and control (without training) groups. The following procedures were performed: occupational history, objective and subjective assessment of hearing protectors. Only subjects in the experimental group received training and guidance on proper hearing protector insertion. Results: Attenuation values were significantly higher in the experimental group than in the control group at all frequencies (500, 1000, 2000, and 4000 Hz) investigated through the objective (MIRE) and subjective (REAT) methods. In addition, attenuation values in the control group were lower than those provided by the hearing protector manufacturer. Conclusion: Both objective and subjective attenuation tests demonstrated the efficacy of training on insertion of hearing protectors because the group that received training on proper hearing protection insertion exhibited higher attenuation values than the untrained group.


RESUMO Objetivo: Determinar a eficácia da colocação do protetor auditivo comparando os valores de atenuação obtidos pelos métodos objetivo (MIRE) e subjetivo (REAT) em grupos com e sem treinamento. Métodos: Participaram do estudo 80 indivíduos do sexo masculino, separados em grupo pesquisa (com treinamento) e controle (sem treinamento). Os procedimentos realizados foram: anamnese e avaliações objetiva e subjetiva do protetor auditivo. Apenas os indivíduos do grupo pesquisa receberam treinamento e orientações para colocar corretamente o protetor auditivo. Resultados: Os valores de atenuação no grupo pesquisa foram maiores com diferenças estatisticamente significantes em relação ao grupo controle em todas as frequências (500, 1000, 2000 e 4000 Hz) investigadas por meio dos métodos objetivo (MIRE) e subjetivo (REAT). Além disso, os valores de atenuação no grupo controle foram menores do que as previstas pelo fabricante do protetor auditivo. Conclusão: Ambos os métodos de avaliação da atenuação (objetivo e subjetivo) demonstraram a eficácia da colocação do protetor auditivo. Entretanto, o grupo que recebeu treinamento para colocação adequada do protetor auditivo apresentou valores de atenuação maiores do que o grupo sem treinamento.


Assuntos
Adolescente , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Dispositivos de Proteção das Orelhas , Capacitação em Serviço/métodos , Ruído Ocupacional/prevenção & controle , Análise de Variância , Limiar Auditivo , Estudos Transversais , Testes Auditivos , Perda Auditiva Provocada por Ruído/prevenção & controle , Exposição Ocupacional/prevenção & controle , Avaliação de Programas e Projetos de Saúde , Padrões de Referência , Reprodutibilidade dos Testes
8.
CoDAS ; 27(4): 309-318, July-Aug. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-760418

RESUMO

PURPOSE: To evaluate and compare the workers' perception of comfort and use aspects regarding two types of hearing protectors (shell and earplug), in three units from a lumbering company, with different implantation times for Hearing Preservation Programs.METHODS: This is a cross-sectional study comparing 440 workers' perception of hearing protectors, from three companies in Paraná State (Brazil), with different times for Hearing Preservation Programs. Two closed questionnaires were applied (9 and 10 questions, respectively), with a scale of answers varying from 1 to 5 (Likert's scale) regarding the perception of the comfort of hearing protectors. Then, audiometry results were analyzed.RESULTS: About 17.5% presented audiogram examinations with alterations. With regard to the questionnaire about the comfort perception, the importance of noise attenuation (mean of 4.25) was the most relevant aspect, followed by communication possibility (mean of 4.15). In the protector assessment, Unit A with more Hearing Preservation Program time presented better scores for both the worker's perception of important aspects regarding hearing protector and for the assessment of the used hearing protector. There was a significant difference on communication difficulty with the use of a hearing protector among workers with normal and altered audiograms (p=0.0371). With regard to the global comfort in the comparison of workers using the shell-type hearing protector with those using insert-type hearing protectors, there was no difference (p=0.2264), irrespective of the type of the unit.CONCLUSION: In general, the unit workers presented a good perception of the important aspects about the hearing protection use of both types of hearing protectors.


OBJETIVO: avaliar e comparar a percepção de trabalhadores sobre aspectos de conforto e uso de dois tipos de protetores auriculares (tipo concha e inserção) em três unidades de uma empresa madeireira com tempos diferentes de implantação de Programas de Preservação Auditiva (PPA).MÉTODOS: trata-se de um estudo transversal, que comparou a percepção de 440 trabalhadores de três unidades de empresa do estado do Paraná, com tempos diferentes de Programa de Preservação Auditiva, sobre protetores auriculares. Foram aplicados dois questionários fechados (9 e 10 questões) com escala de respostas de 1 a 5 (escala Likert) sobre percepção de conforto de protetores auriculares e analisadas as audiometrias.RESULTADOS: 17,5% apresentaram audiogramas alterados. Em relação ao questionário de percepção de conforto, a importância da atenuação do ruído (média 4,25) foi o aspecto mais relevante, seguido da possibilidade de comunicação (média 4,15). Na avaliação do protetor utilizado, a Unidade A com mais tempo de PPA apresentou pontuações melhores tanto para a percepção dos aspectos importantes do protetor auricular pelos trabalhadores quanto na avaliação do protetor auricular utilizado. Houve diferença significativa sobre a dificuldade de comunicação com o uso de protetor auricular entre trabalhadores com audiogramas normais e alterados (p=0,0371). Quanto ao conforto global na comparação dos trabalhadores usuários do protetor auricular do tipo concha com os do tipo inserção, não houve diferença (p=0,2264) independente da Unidade.CONCLUSÃO: Em geral, os trabalhadores das unidades apresentaram uma boa percepção de aspectos importantes da proteção auditiva para a utilização de ambos os tipos de protetores auriculares.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Dispositivos de Proteção das Orelhas , Perda Auditiva Provocada por Ruído/prevenção & controle , Ruído Ocupacional/prevenção & controle , Doenças Profissionais/prevenção & controle , Brasil , Estudos Transversais , Testes Auditivos , Percepção , Inquéritos e Questionários
9.
Artigo em Inglês | LILACS | ID: biblio-962173

RESUMO

OBJECTIVE To analyze whether sociodemographic, occupational, and health-related data are associated with the use of hearing protection devices at work, according to gender. METHODS A cross-sectional study was conducted in 2006, using a random sample of 2,429 workers, aged between 18 and 65 years old, from residential sub-areas in Salvador, BA, Northeastern Brazil. Questionnaires were used to obtain sociodemographic, occupational, and health-related data. Workers who reported that they worked in places where they needed to shout in order to be heard were considered to be exposed to noise. Exposed workers were asked whether they used hearing protection devices, and if so, how frequently. Analyses were conducted according to gender, with estimates made about prevalence of the use of hearing protection devices, prevalence ratios, and their respective 95% confidence intervals. RESULTS Twelve percent (12.3%) of study subjects reported that they were exposed to noise while working. Prevalence of the use of hearing protection devices was 59.3% for men and 21.4% for women. Men from higher socioeconomic levels (PR = 1.47; 95%CI 1.14;1.90) and who had previous audiometric tests (PR = 1.47; 95%CI 1.15;1.88) were more likely to use hearing protection devices. For women, greater perceived safety was associated with the use of protection devices (PR = 2.92; 95%CI 1.34;6.34). This perception was specifically related to the presence of supervisors committed to safety (PR = 2.09; 95%CI 1.04;4.21), the existence of clear rules to prevent workplace injuries (PR = 2.81; 95%CI 1.41;5.59), and whether they were informed about workplace safety (PR = 2.42; 95%CI 1.23;4.76). CONCLUSIONS There is a gender bias regarding the use of hearing protection devices that is less favorable to women. The use of such devices among women is positively influenced by their perception of a safe workplace, suggesting that gender should be considered as a factor in hearing conservation programs.


OBJETIVO Analisar se dados sociodemográficos, ocupacionais e de saúde estão associados ao uso de equipamento de proteção auditiva no trabalho, segundo gênero. MÉTODOS Estudo transversal com amostra aleatória de 2.429 trabalhadores de 18 a 65 anos de subáreas de base domiciliar em Salvador, BA, no ano de 2006. Foram aplicados questionários para obtenção de dados sociodemográficos, ocupacionais e de saúde. Foram considerados expostos ao ruído aqueles que relataram trabalhar em local onde era necessário gritar para ser ouvido. Os trabalhadores expostos foram questionados sobre uso e regularidade do uso de equipamento de proteção auditiva. A análise foi conduzida por gênero, estimando-se a prevalência do uso do equipamento de proteção auditiva, razões de prevalência e os respectivos intervalos de 95% de confiança. RESULTADOS Entre os participantes do estudo, 12,3% referiram trabalhar expostos ao ruído. A prevalência do uso do equipamento de proteção auditiva foi 59,3% e 21,4%, para homens e mulheres, respectivamente. Entre os homens, maior nível socioeconômico (RP = 1,47; IC95% 1,14;1,90) e ter realizado audiometria (RP = 1,47; IC95% 1,15;1,88) foram fatores associados ao uso do equipamento. Entre as mulheres, a percepção de maior segurança associou-se ao uso do equipamento (RP = 2,92; IC95% 1,34;6,34). Essa percepção deveu-se, especialmente, à presença de supervisores comprometidos com a segurança (RP = 2,09; IC95% 1,04;4,21), à existência de regras claras para evitar acidentes de trabalho (RP = 2,81; IC95% 1,41;5,59) e ao recebimento de informações sobre segurança no trabalho (RP = 2,42; IC95% 1,23;4,76). CONCLUSÕES Há um viés de gênero em relação ao uso do equipamento de proteção auditiva menos favorável às mulheres em comparação com os homens. O uso do equipamento entre mulheres é influenciado positivamente pela percepção de um ambiente de trabalho seguro, sugerindo que o gênero precisa ser considerado nos programas de conservação auditiva.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Idoso , Adulto Jovem , Dispositivos de Proteção das Orelhas/estatística & dados numéricos , Perda Auditiva Provocada por Ruído/prevenção & controle , Ruído Ocupacional/prevenção & controle , Doenças Profissionais/prevenção & controle , Percepção , Fatores Socioeconômicos , Brasil , Fatores Sexuais , Estudos Transversais , Inquéritos e Questionários , Local de Trabalho , Testes Auditivos , Pessoa de Meia-Idade
10.
Braz. j. otorhinolaryngol. (Impr.) ; 80(6): 515-521, Nov-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-730450

RESUMO

Introduction: Impact noise is characterized by acoustic energy peaks that last less than a second, at intervals of more than 1 s. Objective: To quantify the levels of impact noise to which police officers are exposed during activities at the shooting range and to evaluate the attenuation of the hearing protector. Methods: Measurements were performed in the shooting range of a military police department. An SV 102 audiodosimeter (Svantek) was used to measure sound pressure levels. Two microphones were used simultaneously: one external and one insertion type; the firearm used was a 0.40 Taurus® rimless pistol. Results: The values obtained with the external microphone were 146 dBC (peak), and a maximum sound level of 129.4 dBC (fast). The results obtained with the insertion microphone were 138.7dBC (peak), and a maximum sound level of 121.6 dBC (fast). Conclusion: The findings showed high levels of sound pressure in the shooting range, which exceeded the maximum recommended noise (120 dBC), even when measured through the insertion microphone. Therefore, alternatives to improve the performance of hearing protection should be considered. .


Introdução: O ruído de impacto é caracterizado por apresentar picos de energia acústica de duração inferior a um segundo, em intervalos superiores a um segundo. Objetivo: Quantificar os níveis de ruído de impacto a que o policial militar fica exposto durante atividades de tiro com armas de fogo e analisar a atenuação do protetor auricular utilizado. Método: As medições foram realizadas no estande de tiros de um Batalhão da Polícia Militar. Para a medição dos níveis de pressão sonora foi utilizado um audiodosímetro modelo SV 102 (Svantek). Foram utilizados dois microfones simultaneamente: um externo e outro tipo inserção, e a arma utilizada foi a pistola calibre 40, da marca Taurus®. Resultados: Os valores obtidos no microfone externo foram de 146 dBC (pico) e ruído máximo de 129,4 dBC (fast). Os resultados obtidos no microfone de inserção foram de 138,7 dBC (pico) e ruído máximo de 121,6 dBC (fast). Conclusão: Nossos achados evidenciaram elevados níveis de pressão sonora no estande de tiros, que ultrapassaram os limites máximos recomendados (120 dBC), mesmo em medição com microfone de inserção. Portanto, alternativas para melhorar o desempenho da proteção auditiva devem ser consideradas pela equipe de segurança da corporação. .


Assuntos
Humanos , Dispositivos de Proteção das Orelhas/normas , Armas de Fogo , Ruído Ocupacional/prevenção & controle , Polícia , Estudos Transversais , Perda Auditiva Provocada por Ruído/prevenção & controle , Estudos Prospectivos
11.
Cienc. Trab ; 15(46): 35-39, abr. 2013. graf
Artigo em Espanhol | LILACS | ID: lil-700415

RESUMO

Objetivo: Determinar las actitudes y creencias de los trabajadores respecto de la protección auditiva y la pérdida de la audición por ruido como parte de una actividad del Programa de Protección Auditiva de un Centro de Trabajo. Método: Se realizó un estudio transversal observacional en un Centro Procesador de aceite crudo y gas natural, costa afuera del estado de Campeche, México. Resultados: La percepción de la susceptibilidad de la pérdida auditiva inducida por el ruido en el grupo de trabajadores fue del 100%. Respecto de percibir la severidad de las consecuencias de la pérdida auditiva inducida por ruido 15% estuvo de acuerdo y 85% totalmente de acuerdo. Del beneficio del uso de los dispositivos como medida preventiva a la pérdida de audición, 90% estuvo totalmente de acuerdo que es importante usar protectores auditivos cada vez que se está trabajando con ruido fuerte, el 10% consideró estar de acuerdo. Conclusión: El estudio de las creencias e intenciones de los trabajadores evidenció un elemento cognoscitivo establecido respecto del ruido como condicionante de la susceptibilidad para pérdida auditiva con el consecuente uso de los dispositivos de protección auditiva como medida preventiva. Sin embargo, se requiere mayor entrenamiento en el plano de la autosuficiencia ya que la mitad de los trabajadores no sabe cuándo los tapones necesitan ser reemplazados. Por otra parte, existen situaciones de tipo administrativo que requieren atención como son la nula posibilidad para los trabajadores de seleccionar dispositivos de protección de los oídos una vez que solo tienen disponibles tapones auditivos.


Objective: Determining the attitudes and beliefs of workers on hearing protection and hearing loss due to noise as part of an activity Hearing Protection Programme of Work Center. Method: An observational cross-sectional study on a crude oil and natural gas Processing Center off shore the state of Campeche, Mexico. Results: The perception of susceptibility hearing loss induced by noise in the group of workers was 100%. Regarding perceive the severity of the consequences of hearing loss induced by noise, 15% agreed and 85% strongly agree. About the benefit of using the devices as a preventive measure against hearing loss, 90% strongly agreed that it is important to wear hearing protection whenever you are working with loud noise, 10% considered agree. Conclusion: The study of the beliefs and intentions of the workers showed a cognitive element established in respect of noise as a condition of susceptibility of hearing loss and the consequent use of hearing protection devices as a precaution. However, more training is required at the level of self-sufficiency half since workers do not know when the plugs need to be replaced. On the other hand, there are situations of administrative nature that require attention such as the non-existent possibility for workers to select hearing protection devices once only earplugs are available.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Conhecimentos, Atitudes e Prática em Saúde , Dispositivos de Proteção das Orelhas , Perda Auditiva Provocada por Ruído/prevenção & controle , Categorias de Trabalhadores/psicologia , Estudos Transversais , Exposição Ocupacional , Desenvolvimento de Pessoal , México , Ruído Ocupacional/prevenção & controle
12.
Braz. j. otorhinolaryngol. (Impr.) ; 77(6): 747-753, nov.-dez. 2011. graf, tab
Artigo em Português | LILACS | ID: lil-608462

RESUMO

A prática de tiro é uma atividade que expõe o policial militar ao ruído de impacto, o que pode causar efeitos irreversíveis na audição. OBJETIVO: Avaliar o conhecimento sobre o ruído e os efeitos do ruído de impacto entre policiais militares que fazem prática de tiro. FORMA DE ESTUDO: Caso controle retrospectivo. MATERIAL E MÉTODO: Participaram 115 militares, sendo 65 expostos ao ruído de impacto e 50 não expostos. Foi realizada a avaliação do nível de ruído das armas de fogo, aplicado um questionário, realizada audiometria tonal limiar e teste de emissões otoacústicas transiente e produto de distorção. RESULTADOS: O nível médio de ruído foi de 125Db (C), a maioria (78 por cento) acredita que o ruído pode causar perda auditiva, 92,3 por cento utilizam protetor auricular nas práticas de tiro, mas grande parte (32,3 por cento) nunca recebeu orientação quanto ao seu uso, o sintoma mais referido foi o zumbido (23 por cento) e 25 por cento dos expostos apresenta perda auditiva sugestiva de induzida por ruído. Houve diferença significativa entre os grupos em relação às alterações auditivas. CONCLUSÃO: Os militares expostos ao tiro são mais suscetíveis a desenvolver perdas auditivas. Há necessidade do desenvolvimento de Programas de Preservação Auditiva nesta população.


Shooting is an activity that exposes military personnel to noise impact, which may cause irreversible effects on hearing. OBJECTIVE: To evaluate impact noise on the hearing of military personnel that practice shooting. STUDY DESIGN: A case-control retrospective study. METHODS: 115 military personnel were enrolled; 65 had been exposed to impact noise and 50 were non-exposed. Firearm noise levels were evaluated, subjects answered a questionnaire and underwent threshold tonal audiometry and otoacoustic emissions testing. RESULTS: The average noise level was 125dB(C). Most subjects (78 percent) believe that noise may cause hearing loss; nearly all (92.3 percent) used ear noise protectors while shooting, but most (32.3 percent) had never received guidance for using this equipment. There were significant differences between the two groups in relation to changes suggesting impact noise-induced hearing loss. CONCLUSION: The differences between groups show that noise-exposed military personnel are more likely to develop hearing loss. The goal of a hearing conservation program for this population should be to preserve hearing and educate these individuals about the importance of using hearing protection correctly.


Assuntos
Adulto , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Armas de Fogo , Conhecimentos, Atitudes e Prática em Saúde , Perda Auditiva Provocada por Ruído/diagnóstico , Militares/estatística & dados numéricos , Ruído Ocupacional/efeitos adversos , Audiometria de Tons Puros , Estudos de Casos e Controles , Dispositivos de Proteção das Orelhas , Perda Auditiva Provocada por Ruído/etiologia , Estudos Retrospectivos , Inquéritos e Questionários
13.
Braz. j. otorhinolaryngol. (Impr.) ; 77(2): 163-170, Mar.-Apr. 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-583828

RESUMO

Police officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system. AIM: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results. STUDY DESIGN: Cross-sectional. MATERIALS AND METHODS: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the praat software. 30 police officers were selected (27 males and 3 females). RESULTS: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and praat was 17.9±0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7 percent of the cases. CONCLUSION: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (praat cochlear response curve) and the frequencies of low hearing acuity.


Os policiais militares estão expostos a ruídos de impacto provenientes de armas de fogo, os quais são capazes de causar lesões irreversíveis ao sistema auditivo. OBJETIVO: Avaliar a exposição ao ruído no estande de tiros durante os exercícios de tiro, analisar acusticamente o ruído de impacto e relacioná-lo com os resultados de audiometria tonal. FORMA DE ESTUDO: Transversal. MATERIAL E MÉTODO: A medição do ruído foi feita por meio de decibelímetro digital e a análise acústica foi feita no software Praat, levantando as curvas de oscilograma e cocleograma. Foi selecionada uma amostra de 30 policiais militares (27 masculinos e 3 femininos). RESULTADOS: Os picos máximos medidos no estante de tiros foram de 113,1 dB(C) para pistola .40 e 116,8 dB(C) para revólver .38. Os valores obtidos por meio da relação entre o oscilograma temporal e cocleograma Praat ficaram entre 17,9±0,3 Barks, correspondendo à faixa entre 4120 e 4580 Hz. As medidas da audiometria indicaram maior perda auditiva na faixa de 4000Hz em 86,7 por cento dos casos. CONCLUSÃO: A partir da análise acústica dos tiros, foi possível demonstrar causa e efeito entre as principais áreas de excitação de energia na cóclea (cocleograma Praat) e as frequências com diminuição de acuidade auditiva.


Assuntos
Feminino , Humanos , Masculino , Armas de Fogo , Perda Auditiva Provocada por Ruído/etiologia , Ruído Ocupacional/estatística & dados numéricos , Polícia , Psicoacústica , Audiometria de Tons Puros , Estudos Transversais , Dispositivos de Proteção das Orelhas , Perda Auditiva Provocada por Ruído/diagnóstico , Ruído Ocupacional/efeitos adversos
14.
J. Soc. Bras. Fonoaudiol ; 23(1): 38-43, jan.-mar. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-586641

RESUMO

OBJETIVO: Verificar a efetividade de uma ação educativa de treinamento, com ênfase na importância da proteção auditiva, para trabalhadores expostos a ruído ocupacional. MÉTODOS: Participaram 78 funcionários do gênero masculino. Todos os indivíduos passaram por avaliação audiológica completa e responderam a um questionário no momento do início do atendimento. Para a segunda aplicação do questionário, os participantes foram randomicamente divididos em dois grupos: Grupo Pesquisa, constituído por 44 funcionários, que responderam ao questionário após passarem por treinamento educativo, e Grupo Controle, constituído por 34 funcionários, que responderem ao questionário antes de passar por treinamento educativo. O treinamento foi feito com base em material gráfico com figuras e textos, sob a forma de conversa. Os temas abordados foram: importância da audição, efeitos do ruído sobre a saúde, importância da prevenção da perda auditiva e da utilização do protetor auditivo, conservação e higienização dos protetores, níveis de ruído no ambiente de trabalho e atenuação do ruído fornecida pelos protetores auditivos. O questionário continha 14 perguntas de múltipla escolha que abordavam os mesmos temas explorados no treinamento educativo. RESULTADOS: Houve aumento significativo do número de acertos durante a 2ª aplicação do questionário, somente para o Grupo Pesquisa, em todas as comparações realizadas. CONCLUSÃO: Ações educativas realizadas com trabalhadores expostos a ruído ocupacional são efetivas. Além disso, o questionário é uma ferramenta estável e viável para a verificação da efetividade de programas educativos.


PURPOSE: To verify the effectiveness of an educational action in the form of training, emphasizing the importance of hearing protection for workers exposed to occupational noise. METHODS: The study included 78 male individuals. All participants answered a questionnaire before they were submitted to audiological evaluation. For the second application of the questionnaire, participants were randomly divided into two groups: Research Group, constituted by 44 subjects that received educational training before the second questionnaire application, and Control Group, comprising 34 individuals that answered the questionnaire before the educational training. Training was based on material with graphic images and text, in the form of conversation. The topics covered included: the importance of hearing, noise effects on health, importance of preventing hearing loss and using hearing protection, conservation and cleaning of hearing protectors, levels of noise in the workplace and noise attenuation provided by hearing protectors. The questionnaire contained 14 multiple choice questions that addressed the same themes explored in the educational training. RESULTS: There was a significant increase of correct responses in the second application of the questionnaire, only in the Research Group, in all comparisons. CONCLUSION: Educational action performed with workers exposed to occupational noise are effective, and the questionnaire is a stable and viable tool to evaluate the effectiveness of educational programs.


Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Educação em Saúde , Perda Auditiva Provocada por Ruído/prevenção & controle , Ruído Ocupacional/prevenção & controle , Doenças Profissionais/prevenção & controle , Inquéritos e Questionários , Pesquisa Comparativa da Efetividade , Dispositivos de Proteção das Orelhas , Conhecimentos, Atitudes e Prática em Saúde
15.
Braz. j. otorhinolaryngol. (Impr.) ; 76(4): 454-461, jul.-ago. 2010. tab
Artigo em Português | LILACS | ID: lil-556876

RESUMO

Músicos de pop-rock apresentam risco de perda auditiva e outros efeitos associados à exposição à música amplificada. OBJETIVO: Avaliar o uso de protetores auditivos em músicos de bandas de pop-rock. Forma de Estudo: Coorte contemporânea. MATERIAL E MÉTODO: Estudo com 23 músicos de pop-rock, do sexo masculino, com idades entre 25 e 45 anos. Após a realização de audiometria tonal, imitância acústica, EOAET e EOAPD, os músicos receberam um protetor auditivo utilizado por três meses e, após esse período, preencheram a um questionário sobre a satisfação em relação ao uso. RESULTADOS: A prevalência de perdas auditivas foi de 21,7 por cento. As principais queixas durante o uso de protetor foram: voz abafada, pressão no ouvido, interferência na percepção dos sons de frequências altas, ao uso do protetor em tempo integral nas apresentações. Houve correlação positiva entre a percepção da diminuição do zumbido após o uso do protetor auditivo com as seguintes queixas: presença de zumbido após iniciar a profissão (p= 0,044), incômodo com a intensidade sonora em seu local de trabalho (p= 0,009) e intolerância a som forte (p= 0,029). CONCLUSÕES: Houve uma elevada prevalência de perdas auditivas e uma tendência favorável à aceitação do protetor auditivo na população estudada.


Pop-rock musicians are at risk of developing hearing loss and other symptoms related to amplified music. AIM: The aim of the present study was to assess the satisfaction provided by the use of hearing protection in pop-rock musicians. Study design: Contemporary cohort study. MATERIALS AND METHODS: A study of 23 male pop-rock musicians, aged between 25 to 45 years. After audiological evaluation (pure tone audiometry, middle ear analysis, TEOAE and DPOAE) hearing protective devices were provided to be used for three months. After that musicians answered a satisfaction assessment questionnaire. RESULTS: The prevalence of hearing loss was of 21.7 percent. The most common complaints about the hearing protectors were: autophonia, pressure in the ears, interference in high frequencies perception and full time use of the hearing protector during concerts. There was a positive correlation between a reduction in tinnitus after the use of the HPD with the following complaints: tinnitus after beginning the career (p= 0.044), discomfort with the sound intensity in the work place (p= 0.009) and intolerance to loud sound (p= 0.029). CONCLUSIONS: There was a high prevalence of hearing loss and a positive tendency towards the use of the ear protector device among the sample population.


Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Dispositivos de Proteção das Orelhas , Perda Auditiva Provocada por Ruído/diagnóstico , Música , Doenças Profissionais/diagnóstico , Zumbido/diagnóstico , Audiometria de Tons Puros , Estudos de Coortes , Perda Auditiva Provocada por Ruído/prevenção & controle , Doenças Profissionais/prevenção & controle , Inquéritos e Questionários , Fatores de Tempo , Zumbido/prevenção & controle
16.
Ciênc. Saúde Colet. (Impr.) ; 15(3): 889-898, maio 2010. ilus
Artigo em Português | LILACS | ID: lil-553108

RESUMO

Neste estudo, buscou-se identificar a exposição sonora e verificar se a proteção auditiva utilizada por esses trabalhadores é adequada para a exposição ao ruído de impacto, durante as atividades de Tiro de Instrução Básico realizadas no Exército Brasileiro, produzidos pelo Fuzil Automático Leve - FAL, calibre 7,62mm. O presente estudo caracteriza-se como analítico, uma vez que busca estabelecer relações causais entre as diversas variáveis envolvidas. Utilizou-se da abordagem qualitativa, no mapeamento do processo de trabalho; e da abordagem quantitativa na analise dos dados em relação a esse processo. Foi possível uma aproximação da realidade a partir de uma triangulação de técnicas de coleta de dados, a saber: observação sistemática; entrevista semi-estruturada e exercício experimental. Diante das análises realizadas, pode-se garantir que esses trabalhadores estão expostos a um NPS mínimo de 147,3 dB durante as atividades de tiro, podendo esse valor atingir 171 dB. Assim, entende-se que a real redução do ruído, oferecida pelo protetor 1100 da 3M, principal modelo utilizado pelos militares, cujo valor de atenuação auditiva corresponde a NRRsf de 12 dB, não caracteriza efetividade na proteção auditiva para os militares.


This study aims to identify the noise exposure and verify if the hearing protection used by these workers is adjusted for the exposure to the impact noise during the activities of Basic Shot Instruction in the Brazilian Army produced by Light Automatic Fusils - FAL, caliber 7.62mm. This study can be considered analytical, since it seeks to establish causal relations among the diverse variables involved. It was used the qualitative approach, in the mapping of the working process; and also the quantitative approach in order to analyze the data in relation to this process. It was possible to have a close estimate of the reality on the basis of data collection triangulation, to include: systematic observation, half structured interview and experimental exercise. Based on the analyses, it can be stated these workers are exposed to a noise which ranges from 147.3 to 171 dB. Therefore, it can be concluded that the 3M 1100 hearing protection, which is largely used by military, do not provide noise reduction, since its reducing value corresponds to NRRsf at 12 dB. Thus, there is no effectiveness in hearing protection for the soldiers.


Assuntos
Humanos , Dispositivos de Proteção das Orelhas , Militares , Ruído Ocupacional/prevenção & controle , Brasil
17.
Arq. int. otorrinolaringol. (Impr.) ; 13(3)jul.-set. 2009. tab
Artigo em Português | LILACS | ID: lil-534653

RESUMO

Introdução: O ruído causa efeitos sobre a audição e em todo organismo. Na audição pode produzir a mudança temporária no limiar (MTL): por um curto prazo o limiar de sensibilidade auditiva é aumentado devido à exaustão metabólica das células ciliadas na presença de sons intensos. Eliminado o ruído, após o repouso auditivo, a audição volta ao seu limiar normal. Os indivíduos que atuam expostos a ruído podem adquirir mudança permanente de limiar (MPL). Uma das formas de evitar a MTL/MPL é usar o protetor auditivo quando em presença de ruído. Objetivo: O objetivo desta pesquisa foi verificar a eficácia dos protetores auditivos usados pelos trabalhadores expostos a ruído de 96,5 dB (L) em uma metalúrgica no interior do Estado de São Paulo. Método: Audiometria tonal antes e após a jornada de trabalho, em 13 trabalhadores usuários de protetores auditivos do tipo inserção, expostos a 96,5 dB (L), para determinar se há MTL. Resultados: Constatou-se que a audição dos trabalhadores não sofreu alterações de limiares audiométricos estatisticamente significante entre o exame pré e pós jornada de trabalho Conclusão: Esta pesquisa mostrou que o uso dos protetores auditivos do tipo inserção foi eficaz, pois não produziu o MTL nos trabalhadores expostos a ruído.


Introduction: The noise causes effects on the hearing and all organism. In hearing it may produce a threshold temporary shift (TTS): for a short term the auditory sensitivity is increased due to the metabolic exhaustion of the hair cells in the presence of intense sounds. When the noise is eliminated, the hearing returns to its normal threshold. The individuals who work exposed to noise may acquire a permanent threshold shift (PTS). One of the ways to avoid the TTS/PTS is using the auditory protection when in the presence of noise. Objective: The objective of this research was to verify the efficacy of the auditory protections used by workers exposed to noise of 96.5 dB (L) in a metallurgic factory in the countryside of the State of São Paulo. Method: Tonal audiometry before and after the working journey in 13 workers users of auditory protection of insertion type, exposed to 96.5 dB (L), to determine whether there is TTS. Results: We confirmed that the hearing of workers did not undergo statistically significant audiometric thresholds shifts between the pre-journey and post-journey exam. Conclusion: This research showed that the use of auditory protections of insertion type was efficient, because it did not produce TTS in the workers exposed to noise.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Audiometria , Dispositivos de Proteção das Orelhas , Eficácia , Saúde Ocupacional , Perda Auditiva/prevenção & controle , Ruído Ocupacional/efeitos adversos
18.
Rev. CEFAC ; 11(2): 345-352, abr.-jun. 2009. graf, tab
Artigo em Português | LILACS | ID: lil-519714

RESUMO

OBJETIVO: analisar a eficácia da colocação de diferentes protetores auriculares em sujeitos treinados e não-treinados e verificar a importância e a necessidade da realização de um treinamento para a colocação adequada do Equipamento de Proteção Individual auricular. MÉTODOS: investigou-se a atenuação de quatro modelos diferentes de protetores auriculares (inserção de espuma, inserção de silicone três flanges, inserção oliva e tipo concha) por meio de duas estratégias: audiometria em campo livre e medidas com microfone sonda, com e sem protetor auricular para comparação e determinação da vedação de ruído. Avaliou-se dois grupos, Grupo 1, sujeitos que receberam treinamento e orientação em relação ao uso e colocação do EPI auricular (23) e o Grupo 2, sujeitos não-treinados (8) universitários que nunca utilizaram o EPI auricular. RESULTADOS: no grupo 1, as diferenças dos limiares auditivos sem e com protetor auricular avaliadas pelos dois métodos apresentaram, em geral, valores de atenuação superiores ao do grupo 2. O protetor auricular concha apresentou valores médios de atenuação superiores aos demais tipos; e o protetor auricular oliva apresentou valores menores. CONCLUSÃO: o treinamento quanto ao uso dos protetores auriculares é necessário e deve ser incluído nos Programa de Conservação Auditiva (PCA).


PURPOSE: to analyze the effectiveness for inserting different hearing protectors in trained and non-trained subjects. METHODS: we investigated the attenuation for four models of hearing protectors (foam earplugs, three-flange silicone earplugs, olive end earplugs and shell earplugs) by means of two strategies, namely, free-field audiometry and microphone probe measurements, with and without h. p. for comparison and determination of noise elimination. Two groups were evaluated: Group 1, with workers trained (23) in the use of hearing protectors, and Group 2, with non-trained ones (8). RESULTS: in group 1, the differences of hearing thresholds with and with no hearing protectors evaluated by the aforementioned methods, in general values, are greater than those of group 2. Shell earplugs submitted average values higher then those of the other types; and olive-end earplugs submitted the minor values. CONCLUSION: training for using hearing protectors is necessary and must be included in Hearing Conservation Programs (HCP).


Assuntos
Dispositivos de Proteção das Orelhas , Audição , Auxiliares de Audição , Transtornos da Audição , Perda Auditiva , Perda Auditiva Provocada por Ruído , Testes Auditivos
19.
Rev. bras. otorrinolaringol ; 74(3): 417-422, maio-jun. 2008. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-487060

RESUMO

Os autores realizaram estudo caso-controle audiométrico em indivíduos com e sem protetor auricular auditivo. OBJETIVOS: O objetivo do estudo foi avaliar a real atenuação individual dado pelos protetores. MATERIAL E MÉTODO: Foram avaliados 30 indivíduos (ou 60 orelhas) de diferentes atividades profissionais, de ambos os sexos, com idades entre 20 e 58 anos, apresentando audição normal e tendo realizado repouso auditivo de 10 horas, submetidos a exame audiométrico com e sem protetor auricular auditivo, no período de fevereiro a julho de 2003, utilizando protetor tipo plugue. Avaliou-se as audiometrias nas vias aérea e óssea em freqüências de 500 a 4000Hz. RESULTADOS: Os resultados foram analisados estatisticamente e comparados aos dados fornecidos pelo fabricante. Assim se observou em ouvido real os níveis de atenuação auditiva obtidos com o uso destes produtos. CONCLUSÃO: Os resultados permitiram chegar à conclusão de que os índices fornecidos pelos fabricantes foram compatíveis com os que obtive nos testes.


The authors evaluated pure tone audiometry with and without specific ear protectors. AIM: The purpose of this case control study was to measure the level of sound attenuation by earplugs. MATERIAL AND METHODS: The evaluation included sixty ears of 30 subjects of both sexes, aged between 20 and 58 years, of various professional activities, with normal hearing thresholds, and following ten hours of auditory rest. The statistical results of pure tone audiometry at 500 to 4000 Hertz with and without specific ear protectors were analyzed. RESULTS: These results were compared with those provided by the ear protector manufacturer. CONCLUSION: The results show that the rate of sound reduction was similar to the manufacturer's specifications.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Audiometria de Tons Puros/métodos , Dispositivos de Proteção das Orelhas/normas , Ruído/prevenção & controle , Dispositivos de Proteção das Orelhas/estatística & dados numéricos , Valores de Referência
20.
Pró-fono ; 20(1): 49-54, jan.-mar. 2008. tab
Artigo em Inglês, Português | LILACS | ID: lil-480041

RESUMO

TEMA: o rock and roll tem como uma de suas principais características os níveis sonoros elevados. Diversos estudos já constataram que estes níveis variam de 100 a 115dB (A), alcançando picos de 150dB (A). OBJETIVO: estudar a audição de músicos de rock and roll, analisando os resultados da avaliação audiológica e investigar a influência da variável tempo de exposição à música amplificada na audição. MÉTODO: foi aplicado um questionário em 23 músicos (46 orelhas), e os mesmos foram avaliados por meio da audiometria tonal, audiometria vocal, medidas de imitância acústica e emissões otoacústicas (evocadas por estímulo transiente - EOAT e produto de distorção - EOAPD). RESULTADOS: com relação ao tempo de exposição à música, foram encontrados valores próximos do limite de aceitação (tendendo a ser significantes), nas freqüências de 0,5 e 6kHz, na audiometria tonal. Também foi encontrada diferença estatisticamente significante na freqüência de 2kHz, no teste de EOAT e diferença estatisticamente significante nas freqüências de 0,75, 1, 4 e 6kHz, no teste de EOAPD. CONCLUSÕES: os resultados mostraram que apesar de não ocorrer perda auditiva na população estudada, já existe alteração no registro das EOA, o que sugere alteração da função coclear. Com relação ao tempo de exposição, os resultados demonstraram que os músicos com carreira superior a dez anos apresentaram diferença estatisticamente significante comparados aos que estão expostos a menos tempo.


BACKGROUND: rock and roll has as one of its main characteristics the excessive sound pressure levels. Several studies have demonstrated that the sound levels of rock concerts can range from 100 to 115dB (A), with peak levels of 150dB (A). AIM: to study the hearing of rock and roll musicians, analyzing the results of the audiological evaluation and verifying the influence of time of exposure to amplified music. METHOD: a questionnaire was answered by 23 rock and roll musicians (46 ears) who were also evaluated by means of pure tone audiometry, immitance audiometry and transient/distortion product evoked otoacoustic emissions (OAET and OAEPD). RESULTS: regarding the time of exposure to music, values close to the limit of acceptance (tending to be significants) were found in the frequencies of 0.5 and 6kHz, in the pure tone audiometry. A statistically significant difference was also found in the OAET test in the frequency of 2kHz and also in the frequencies of 0.75, 1, 4 and 6kHz in the OAEPD test. CONCLUSION: the results indicate that although hearing loss was not found in the studied population, alteration in the register of the OAE already exists, suggesting alteration of the cochlear function. Regarding time of exposure, the results indicate that musicians with more than 10 years of practice present statistically significant differences when compared to those with less time of exposure.


Assuntos
Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Percepção Auditiva/fisiologia , Perda Auditiva Provocada por Ruído/etiologia , Audição/fisiologia , Música , Ruído Ocupacional/efeitos adversos , Doenças Profissionais/etiologia , Análise de Variância , Audiometria de Tons Puros , Estudos Transversais , Cóclea/fisiologia , Dispositivos de Proteção das Orelhas , Perda Auditiva Provocada por Ruído/prevenção & controle , Fatores de Tempo , Zumbido/etiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...