1.
Odovtos (En línea) ; 21(2): 63-72, May.-Aug. 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1091482

RESUMO

ABSTRACT The purpose of this preliminary study is to evaluate the push-out bond strength (PBS) of experimental dentin posts (EDPs) obtained from human and bovine teeth sterilized by autoclaving and gamma radiation. Eighty-four mandibulary premolars were obturated and divided into three post groups: the glass fiber group (Fb) human EDP group (Hm) and the bovine EDP group (Bv). Three subgroups (n=12) were obtained for each EDP groups according to the sterilization methods; no sterilization (Cnt), steam autoclaving (Aut), and gamma radiation (Rad) a total dose of 25 kGy. All posts were cemented to root canals using a dual cured resin cement (Panavia SA). After the micro slices (1mm in thickness) were obtained of each subgroup, PBS test was performed. Data were analyzed using two-way ANOVA and Tukey's multiple comparison tests (α=.05). The post type and sterilization method was significantly effective on the PBS values according to the ANOVA (P<.001). No sterilization apllied EDP groups showed significantly higher PBS values than the sterilized groups (P<.001). Bv_Cnt (9.42 ±1.31) showed significantly lower PBS values than both Fb (12.36 ±1.54) and Hm_Cnt (11.06 ±1.38) groups (P<.001). Both steam autoclaving and gamma radiation affect the PBS values and fracture modes of EDPs negatively. The bovine EDPs are not as effective as human EDPs with regard to the PBS to the root dentin.


RESUMEN El propósito de este estudio preliminar es evaluar el push-out bond strength de los postes de dentina experimentales (PDE) obtenidos de dientes humanos y bovinos esterilizados por autoclave y radiación gamma. Ochenta y cuatro premolares mandibulares fueron obturadores y se dividieron en tres grupos experimentales de postes: el grupo de fibra de vidrio (Fb) grupo PDE humano (Hm) y el grupo PDE bovino (Bv). Se obtuvieron tres subgrupos (n=12) para cada grupo de PDE según los métodos de esterilización; sin esterilización (Cnt), autoclave a vapor (Aut) y radiación gamma (Rad) con una dosis total de 25 kGy. Todos los postes se cementaron a los conductos radiculares utilizando un cemento de resina de curado doble (Panavia SA). Después de que se obtuvieron las micro rebanadas (1 mm de espesor) de cada subgrupo, se realizó una prueba de push-out bond strength. Los datos se analizaron utilizando ANOVA de dos vías y las pruebas de comparación múltiple de Tukey (α=.05). El tipo de poste y el método de esterilización fueron significativamente efectivos en los valores de push-out bond strength según el ANOVA (P <.001). Los grupos de PDE no aplicados a la esterilización mostraron valores de push-out bond strength significativamente mayores que los grupos esterilizados (p <0,001). Bv_Cnt (9.42 ±1.31) mostró valores de push-out bond strength significativamente más bajos que los grupos Fb (12.36 ±1.54) y Hm_Cnt (11.06 ±1.38) (P <.001). Tanto el autoclave al vapor como la radiación gamma afectan negativamente los valores de push-out bond strength y los modos de fractura de los PDE. Los PDE bovinos no son tan efectivos como los PDE humanos con respecto a la fuerza de adhesión a la dentina de la raíz.


Assuntos
Esterilização/métodos , Dentina/efeitos dos fármacos , Dente/efeitos da radiação , Materiais Dentários , Equipamentos e Provisões para Radiação
2.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-777230

RESUMO

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm2 of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey’s tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm2 (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm2 at all curing distances.


Assuntos
Luzes de Cura Dentária , Resinas Compostas/efeitos da radiação , Cura Luminosa de Adesivos Dentários/instrumentação , Cura Luminosa de Adesivos Dentários/métodos , Análise de Variância , Resinas Compostas/química , Equipamentos Odontológicos , Teste de Materiais , Polimerização/efeitos da radiação , Doses de Radiação , Equipamentos e Provisões para Radiação , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo