Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Filtros aplicados
Intervalo de ano de publicação
1.
J. oral res. (Impresa) ; 9(5): 405-413, oct. 31, 2020. ilus, graf, tab
Artigo em Inglês | LILACS | ID: biblio-1179032

RESUMO

Introduction: This study evaluated the influence of sonic vibration and thermocycling on the bond strength of fiberglass posts using conventional dual-cured and self-adhesive resin cements. Material and Methods: Ninety-six single-rooted endodontically treated teeth were divided randomly into eight groups according to the cement used (dual-cured or self-adhesive resin cement), use of sonic vibration during post accommodation, and aging conditions (24h in distilled water or 5,000 thermal cycles). The fiberglass posts (White Post DC1, FGM) were cleaned with alcohol, treated with silane and cemented with dual-cured (Allcem Core, FGM) or with self-adhesive resin cement (seT, SDI). For groups in which sonic vibration was used, the posts were accommodated, and sonic vibration was applied for 10 s using a special tip placed on top of the post (Sonic Smart Device, FGM). Pull-out tests were performed after storage in distilled water for 24h at 37°C or after thermocycling (5000 cycles, at 5°C and 55°C). The results were evaluated using three-way ANOVA and Tukey's test (α=0.05). Results: Significant differences were not observed between the bond strengths of dual-cured (87.93±41.81 N) and self-adhesive cement (82.53±41.43 N). Bond strength for the sonic vibration groups (100.36±42.35 N) was significantly higher than for groups without sonic vibration (70.13±34.90 N). There were significant differences between specimens subjected to thermocycling (98.33±39.42 N) and those stored for 24h in distilled water (72.16±39.67 N). Conclusion: It can be concluded that both sonic vibration and thermocycling significantly improved bond strength of fiberglass posts with the two evaluated resin cements.


Introducción: Este estudio evaluó la influencia de la vibración sónica y el termociclado en la fuerza de unión de los postes de fibra de vidrio utilizando cementos de resina autoadhesivos y de curado dual convencionales Material y Métodos: Se dividieron aleatoriamente noventa y seis dientes tratados endodónticamente de raíz única en ocho grupos según el cemento utilizado (cemento de resina de curado dual o autoadhesivo), el uso de vibración sónica durante la acomodación posterior y las condiciones de envejecimiento (24 horas agua destilada o 5.000 ciclos térmicos). Los postes de fibra de vidrio (White Post DC1, FGM) se limpiaron con alcohol, se trataron con silano y se cementaron con cemento de curado dual (Allcem Core, FGM) o con cemento de resina autoadhesivo (seT, SDI). Para los grupos en los que se utilizó vibración sónica, se acomodaron los postes y se aplicó la vibración sónica durante 10 s utilizando una punta especial colocada en la parte superior del poste (Sonic Smart Device, FGM). Las pruebas de extracción se realizaron después del almacenamiento en agua destilada durante 24 horas a 37ºC o después del termociclado (5000 ciclos, a 5ºC y 55ºC). Los resultados se evaluaron mediante ANOVA de tres vías y la prueba de Tukey (α = 0.05). Resultados: No se observaron diferencias significativas entre las resistencias de adhesión del cemento de curado dual (87,93 ± 41,81 N) y el cemento autoadhesivo (82,53 ± 41,43 N). La fuerza de unión para los grupos de vibración sónica (100,36 ± 42,35 N) fue significativamente mayor que para los grupos sin vibración sónica (70,13 ± 34,90 N). Hubo diferencias significativas entre los especímenes sometidos a termociclado (98,33 ± 39,42 N) y los almacenados durante 24 h en agua destilada (72,16 ± 39,67 N). Conclusión: Se puede concluir que tanto la vibración sónica como el termociclado mejoraron significativamente la fuerza de unión de los postes de fibra de vidrio con los dos cementos de resina evaluados.


Assuntos
Humanos , Vibração , Técnica para Retentor Intrarradicular/instrumentação , Cimentos de Resina/química , Resistência à Flexão , Vidro , Sonicação/métodos , Raiz Dentária , Colagem Dentária , Adesivos Dentinários , Dentina/química , Ondas Ultrassônicas
2.
Rev. bras. cir. cardiovasc ; 35(5): 824-830, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | LILACS, Sec. Est. Saúde SP | ID: biblio-1137319

RESUMO

Abstract Objective: To investigate the cardiovascular effects produced by transthoracic application of low-intensity pulsed ultrasound therapy (LIPUST). Methods: Three-month-old male Wistar rats (± 300 g, N=16) were randomly allocated in two groups, namely SHAM (control group, faked procedures) and UST (animals treated with LIPUST). These animals, under anesthesia, were instrumented (femoral artery and vein catheterization) for hemodynamic recordings (mean blood pressure [MBP], heart rate [HR]) and blood biochemical profile (lipids, creatine kinase-myocardial band [CK-MB]). Then, LIPUST (spatial average-temporal average [ISATA] 1-MHz, power 0.1 to 1.2 W/cm2, pulsed 2:8 ms, cycle at 30%, for three minutes) was applied to animals from the UST group, externally to their thorax. SHAM animals were equally manipulated, but without application of ultrasound energy. After the hemodynamic and biochemical measurements, animals were sacrificed, and their hearts were mounted in a Langendorff apparatus for coronary reactivity evaluation. Standard histology techniques were employed to analyze the hearts. Results: LIPUST application caused statistically significant reductions in MBP (92±4 vs. 106±1 mmHg) and HR (345±14 vs. 380±17 rpm) when compared with SHAM procedures. UST rats exhibited higher CK-MB levels (318±55 vs. 198±26 U/dL) and lower plasma triglycerides levels (38±7 vs. 70±10 mg/dL) than SHAM animals. Coronary reactivity was not significantly changed by LIPUST. Cardiac histopathology showed an increase in capillary permeability in treated animals when compared with SHAM animals. Conclusion: Noninvasive LIPUST induces significant metabolic and hemodynamic changes, including intensity-dependent bradycardia and hypotension, indicating a possible therapeutic effect for cardiac events.


Assuntos
Animais , Masculino , Ratos , Bradicardia/terapia , Hipotensão , Miocárdio , Ratos Wistar , Ondas Ultrassônicas , Coração , Hemodinâmica
3.
J. appl. oral sci ; 28: e20190145, 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1056576

RESUMO

Abstract Ultrasonic wave technology is widely used during dental treatments. We previously demonstrated that this method protects the gingival tissue. However, the physiological change on the gingival microvasculature caused by this method remains unclear. Objective The aim of this study was to investigate the relationship between the morphological and physiological effects on gingival microcirculation when preparing teeth, using the conventional dental turbine or ultrasonic method. Methodology The lower premolar teeth of beagle dogs were prepared along the gingival margin by using a dental turbine or ultrasonic wave instrument. Gingival vasculature changes were investigated using scanning electron microscopy for corrosion resin casts. Gingival blood flow at the preparation site was determined simultaneously by laser Doppler flowmetry. These assessments were performed immediately (Day 0), at 7 days and 30 days after tooth preparation. Results At day 0, in the turbine group, blood vessels were destroyed and some resin leaked. Furthermore, gingival blood flow at the site was significantly increased. In contrast, the ultrasonic group demonstrated nearly normal vasculature and gingival blood flow similar to the non-prepared group for 30 days after preparation. No significant alterations occurred in gingival circulation 30 days after either preparation; however, the turbine group revealed obvious morphological changes. Conclusions Based on multiple approach analyses, this study demonstrated that ultrasonic waves are useful for microvascular protection in tooth preparation. Compared with a dental turbine, ultrasonic wave instruments caused minimal damage to gingival microcirculation. Tooth preparation using ultrasonic wave instruments could be valuable for protecting periodontal tissue.


Assuntos
Humanos , Animais , Feminino , Cães , Preparo do Dente/instrumentação , Ondas Ultrassônicas , Gengiva/irrigação sanguínea , Microcirculação/fisiologia , Fatores de Tempo , Microscopia Eletrônica de Varredura , Protocolos Clínicos , Reprodutibilidade dos Testes , Fluxometria por Laser-Doppler/métodos , Preparo do Dente/métodos , Instrumentos Odontológicos
4.
Braz. dent. j ; 30(1): 58-65, Jan.-Feb. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-989434

RESUMO

Abstract The aim of this study was to evaluate different conditioning protocols and sonic/ultrasonic application of an infiltrant resin (IR) in artificial white spot lesions (AWSL). the V/L surfaces of 48 molars were induced to an AWSL and divided in 6 groups, according to the conditioning protocols and application technique: 15% hydrochloric acid (HA) + manual application of the IR; HA + 37% phosphoric acid (PA) + manual application of the IR; HA + ultrasonic application (U) of the IR; HA + sonic application (S) of the IR; PA+HA+S; and PA+HA+U. For the Penetration Depth (PD), the crowns were etched with HA for 120s. The IR Icon® (DMG) was applied according to the manufacturer`s instructions. The crowns were dye penetrated (0.1% red fluorophore rhodamine B isothiocyanate for 12h) and bleached with 30% hydrogen peroxide for 12 h. The discs were immersed in a 50% ethanol solution, containing 100 µM of sodium fluorescein. The PD (in µm) was measured using confocal laser scanning microscopy (20x). The bond strength (BS) was performed by michoshear test (0.5 mm/min). Data were submitted to 2-way ANOVA and Tukey (α=0.05). For BS, the interaction was not significant (p>0.05). For PD, the main factors were significant (application - p<0.001; conditioning technique - p=0.003). The ultrasonic application showed the highest PD values. PA+HA presented higher results than HA. The sonic/ultrasonic applications and the use of phosphoric acid prior to hydrochloric acid improved PD of the infiltrant resin. Conditioning protocols or application techniques did not influence BS values.


Resumo: O objetivo deste estudo foi avaliar diferentes protocolos de condicionamento e a aplicação sônica/ultrassônica de uma resina infiltrante (RI) em lesões de mancha branca produzidas artificialmente (LMBA). As superfícies vestibulares/linguais de 48 molares foram induzidas à formação de LMBA e divididas em 6 grupos, de acordo com os protocolos de condicionamento e técnica de aplicação da resina infiltrante: ácido hidroclorídrico 15% (AH) + aplicação manual da RI; AH + ácido fosfórico 37% (AF) + aplicação manual da RI; AH + aplicação ultrassônica da RI (U); AH + aplicação sônica da RI (S); AF + AH + S; e AF + AH + U. para o grau de penetração (GP), condicionou-se as coroas com AH por 120 s. A RI Icon® (DMG) foi aplicada de acordo com as instruções do fabricante. As coroas foram coradas (rodamina B 0,1% por 12 h) e clareadas com peróxido de hidrogênio 30% por 12 h. os discos foram imersos em solução de etanol 50%, contendo 100 µM de fluoresceína sódica. O GP (em µm) foi mensurado por meio de microscopia confocal a laser (20´). A resistência de união (RU) foi calculada pelo teste de microcisalhamento (0,5 mm/min). Os dados foram submetidos ao teste ANOVA 2 fatores e Tukey (α=0,05). Para RU, a interação não foi significante (p>0,05). Para GP, os fatores principais foram significantes (técnica de aplicação - p<0,001; protocolos de condicionamento - p=0,003). A aplicação U mostrou os maiores valores de GP. AF+AH demonstrou resultados superiores ao grupo AH. As aplicações sônica/ultrassônica e o uso do ácido fosfórico antes do ácido hidroclorídrico aumentaram o GP da resina infiltrante. Os protocolos de condicionamento ou as técnicas de aplicação não influenciaram os valores de RU.


Assuntos
Humanos , Rodaminas/química , Cor , Resinas Compostas/química , Esmalte Dentário , Estética Dentária , Ondas Ultrassônicas , Microscopia Confocal
5.
Braz. oral res. (Online) ; 33: e0045, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019594

RESUMO

Abstract The aim of this study was to investigate the effects of low-intensity pulsed ultrasound (LIPUS) on the osteogenic differentiation of dental follicle cells (DFCs) in vitro and on the regenerative effects of DFC-OsteoBoneTM complexes in vivo. DFCs were isolated and characterized. In the in vitro study, DFCs were cultured in an osteogenic medium in the presence or absence of LIPUS. The expression levels of ALP, Runx2, OSX, and COL-I mRNA were analyzed using real-time polymerase chain reaction (RT-PCR) on day 7. Alizarin red staining was performed on day 21. The state of the growth of the DFCs that were seeded on the scaffold at 3, 5, 7, and 9 days was detected by using a scanning electron microscope. In our in vivo study, 9 healthy nude mice randomly underwent subcutaneous transplantation surgery in one of three groups: group A, empty scaffold; group B, DFCs + scaffold; and group C, DFCs + scaffold + LIPUS. After 8 weeks of implantation, a histological analysis was performed by HE and Mason staining. Our results indicate that LIPUS promotes the osteogenic differentiation of DFCs by increasing the expression of the ALP, Runx2, OSX, and COL-I genes and the formation of mineralized nodules. The cells can adhere and grow on the scaffolds and grow best at 9 days. The HE and Mason staining results showed that more cells, fibrous tissue and blood vessels could be observed in the DFCs + scaffold + LIPUS group than in the other groups. LIPUS could promote the osteogenic differentiation of DFCs in vitro and promote tissue regeneration in a DFCs-scaffold complex in vivo. Further studies should be conducted to explore the underlying mechanisms of LIPUS.


Assuntos
Animais , Osteogênese/efeitos da radiação , Terapia por Ultrassom/métodos , Regeneração Óssea/efeitos da radiação , Saco Dentário/citologia , Ondas Ultrassônicas , Fatores de Tempo , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Cerâmica , Reprodutibilidade dos Testes , Ratos Sprague-Dawley , Saco Dentário/efeitos da radiação , Reação em Cadeia da Polimerase em Tempo Real , Citometria de Fluxo , Camundongos Nus
6.
J. appl. oral sci ; 27: e20180556, 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1019971

RESUMO

Abstract Objective: To evaluate the effect of ultrasonic and sonic activation on physicochemical properties of AH Plus, MTA Fillapex, ADSeal, GuttaFlow Bioseal, and GuttaFlow 2 sealers. Methodology: Three experimental groups were formed: no activation (NA), ultrasonic activation (UA), and sonic activation (SA). The sealers were manipulated according to the manufacturers' instructions. A 3-mL syringe was adapted to receive 1 mL of sealer. Activation was performed with a 20/.01 ultrasonic insert (20 s/1W) in the UA group. A size 35.04 sonic tip was used (20 s/10,000 cycles/min-1) in the SA group. The molds for physicochemical analysis were filled and evaluated according to ANSI/ADA specification no. 57: setting time (ST), flow (FL), dimensional change (DC), solubility (SB), and radiopacity (RD). Statistical analysis was performed by Kruskal-Wallis, one-way ANOVA, and Tukey's tests (P<0.05). Results: Regarding ST, only AH Plus and GuttaFlow 2 in the NA group met the ANSI/ADA standards. All FL values were greater than 20 mm in diameter, as determined by ANSI/ADA. The tested sealers and protocols did not comply with the ANSI/ADA standards for DC. As for SB, only MTA Fillapex, regardless of the activation protocol, did not follow the ANSI/ADA standards. All of the investigated sealers, regardless of the activation protocol, presented radiographic density higher than 3 mm Al, as proposed by ANSI/ADA. Conclusions: UA and SA promoted changes in the physicochemical properties of the evaluated root canal sealers, mainly in ST and F. Thus, it is important to evaluate the physicochemical properties of endodontic sealers associated with activation techniques prior to clinical application in order to determine whether the properties follow the parameters set by ANSI/ADA, ensuring safety and quality of root canal filling.


Assuntos
Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Compostos de Cálcio/química , Compostos de Alumínio/química , Dimetilpolisiloxanos/química , Resinas Epóxi/química , Ondas Ultrassônicas , Guta-Percha/química , Valores de Referência , Solubilidade , Propriedades de Superfície , Fatores de Tempo , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Combinação de Medicamentos
7.
Braz. j. med. biol. res ; 51(12): e7862, 2018. graf
Artigo em Inglês | LILACS | ID: biblio-974259

RESUMO

Although the effects of low-intensity pulsed ultrasound (LIPUS) on diverse cell types have been fully studied, the functional role of LIPUS in keratinocytes remains poorly understood. This study aimed to investigate the effects of LIPUS on proliferation and migration of HaCaT cells as well as the regulatory mechanisms associated with signaling pathways. Human HaCaT cells were exposed or not to LIPUS, and cell proliferation and migration were measured by BrdU incorporation assay and Transwell assay, respectively. Expression of proteins associated with proliferation and migration was evaluated by western blot analysis. Expression of key kinases in the PI3K/AKT and JNK pathways was also evaluated by western blot analysis. Effects of LIPUS on the PI3K/AKT and JNK pathways, and whether LIPUS affected HaCaT cells via these two pathways were finally explored. When the parameter of LIPUS (number of cycles) was set at 300, cell viability was the highest after LIPUS stimulation. We then found that the percentage of BrdU positive cells was enhanced by LIPUS, along with up-regulation of cyclinD1, CDK6, CDK4, and VEGF. LIPUS promoted migration, as well as up-regulation of MMP-2 and MMP-9. Phosphorylation levels of key kinases in the PI3K/AKT and JNK pathways were increased by LIPUS. Inhibition of either PI3K/AKT pathway or JNK pathway attenuated effects of LIPUS on HaCaT cells, and co-inhibition of these two pathways showed augmented effects. LIPUS promoted proliferation and migration of HaCaT cells through activating the PI3K/AKT and JNK pathways.


Assuntos
Queratinócitos/efeitos da radiação , Movimento Celular/efeitos da radiação , Fosfatidilinositol 3-Quinases/efeitos da radiação , Sistema de Sinalização das MAP Quinases/efeitos da radiação , Proliferação de Células/efeitos da radiação , Ondas Ultrassônicas , Bromodesoxiuridina , Linhagem Celular Transformada , Transdução de Sinais/efeitos da radiação , Queratinócitos/metabolismo , Regulação para Cima , Sobrevivência Celular/efeitos da radiação , Western Blotting , Reprodutibilidade dos Testes , Análise de Variância , Fosfatidilinositol 3-Quinases/metabolismo , Metaloproteinase 2 da Matriz/metabolismo , Metaloproteinase 9 da Matriz/metabolismo
8.
Clín. int. j. braz. dent ; 12(2): 192-195, abr.-jun. 2016.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1219

RESUMO

As microinfiltrações em restaurações de resina composta constantemente são referidas como principal motivo de insucesso do procedimento restaurador. Com a necessidade de otimizar o tempo de atendimento aos pacientes e torná-lo menos desconfortável, passou-se a utilizar os aparelhos de ultrassom como instrumentos atuantes no auxílio de procedimentos de raspagem periodontal. Este artigo discorre sobre estudos na literatura que abordam a relação entre o uso da instrumentação ultrassônica em procedimentos periodontais e as deficiências no selamento marginal das restaurações em resina composta(AU)


Microleakage of composite resin restorations is consistently reported as the main reason for failure of this restorative procedure. Ultrasonic devices have been developed to reduce patient's chair time and to make periodontal scaling procedures less uncomfortable. This article discusses studies that address the relationship between the use of ultrasonic instrumentation used for periodontal procedures and failure of the marginal sealing of composite resin restorations(AU)


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Ultrassom , Infiltração Dentária , Ondas Ultrassônicas
9.
Clinics ; 71(3): 140-144, Mar. 2016. graf
Artigo em Inglês | LILACS | ID: lil-778991

RESUMO

OBJECTIVE: The assessment of fracture union includes physical examination and radiographic imaging, which depend on the examiner’s experience. The development of ancillary methods may avoid prolonged treatments and the improper removal of implants. Quantitative bone ultrasonometry has been studied for this purpose and will soon be included in clinical practice. The aims of the present study were to assess the feasibility of using this technique on the clavicle and to standardize its in vivo application. METHODS: Twenty adult volunteers, including 10 men and 10 women without medical conditions or a previous history of clavicle fracture, underwent axial quantitative ultrasonometric assessment using transducers in various positions (different distances between the transducers and different angulations relative to the clavicle). RESULTS: Similar values of wave propagation velocity were obtained in the different tested set-ups, which included distinct distances between the transducers and angular positions relative to the clavicle. There were significant differences only in the transducers positioned at 0° and at 5 or 7 cm apart. CONCLUSIONS: The use of bone ultrasonometry on the clavicle is feasible and the standardization of the technique proposed in this study (transducers placed at 45° and at 7 cm apart) will allow its future application in clinical trials to evaluate the healing process of diaphyseal fractures of the clavicle.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Clavícula , Osso e Ossos , Estudos de Viabilidade , Padrões de Referência , Transdutores/normas , Ondas Ultrassônicas
10.
Acta cir. bras ; 31(1): 36-43, Jan. 2016. graf
Artigo em Inglês | LILACS | ID: lil-771853

RESUMO

PURPOSE: To determine the effectiveness of low-intensity therapeutic ultrasound (LITUS) on wound healing in rats with third-degree burns. METHODS: Twenty rats were divided into the Control Group that comprised four rats without third-degree burns that did not undergo LITUS, the Burned Group (BG), comprising eight rats with third-degree burns that did not undergo LITUS, and the Burned with Treatment Group (BTG), comprising eight rats with third-degree burns that were administered LITUS. LITUS began 24 h after injury and involved daily applications for 8 min at 0.1 W/cm2 for 14 days. RESULTS: The BTG lost less weight than the BG (Q=2.75; p<0.05). No visible differences were apparent among the groups' lesions on day 4. By the end of treatment, wound healing was more evident in the BTG. No statistically significant differences were found between the BG and the BTG in relation to the parameters measured using the histological changes in burn wound healing scoring system. CONCLUSION: The LITUS protocol applied to the animals with third-degree burns accelerated the formation of fibrin-leukocyte crusts and significantly reduced weight loss. However, burn wound healing was not accelerated.


Assuntos
Animais , Masculino , Queimaduras/terapia , Tecido Conjuntivo/lesões , Ondas Ultrassônicas , Cicatrização , Queimaduras/classificação , Queimaduras/patologia , Fibrina/metabolismo , Temperatura Alta/efeitos adversos , Ratos Wistar , Reepitelização , Redução de Peso
11.
Braz. oral res. (Online) ; 30(1): e16, 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-952011

RESUMO

Abstract The aim of this study is to evaluate the solubility of a Mineral Trioxide Aggregate sealer (MTA-Fillapex) compared with five other sealers, calcium hydroxide (Sealapex), resin (Realseal), zinc oxide-eugenol (Tubli-Seal), and two epoxy resins (AH-26 and AH-Plus), in chloroform and eucalyptoil in static and ultrasonic environments. Samples of each sealer were prepared (n = 180) and then divided into 12 groups that were immersed in solvents for 5 and 10 min in static and ultrasonic environments. The mean weight loss was determined, and the values were compared using Student's t-test, One-way ANOVA, and Tukey's HSD post-hoc test (p < 0.05). In chloroform, MTA-Fillapex, AH-26, and Sealapex displayed moderate solubility with no significant difference in dissolution (p = 0.125); however, their dissolution was significantly lower than that of AH-Plus (p < 0.001), which was almost fully dissolved after 10 minutes. Realseal was significantly less soluble than all sealers (p < 0.001). In eucalyptoil, MTA-Fillapex showed low solubility, as all of the sealers did, but Tubli-Seal was significantly more soluble than other sealers (p < 0.001). Using ultrasonic activation resulted in a significantly higher dissolution rate in chloroform for all sealers except MTA-Fillapex after 10 min (p = 0.226). In eucalyptoil, ultrasonic activation significantly increased the dissolution rate of all sealers except MTA-Fillapex after 5 and 10 min, Sealapex at 10 min, and AH-Plus at 5 min (p > 0.05). In conclusion, MTA-Fillapex was not sufficiently dissolved in either solvent. Ultrasonic activation had limited effectiveness on MTA-Fillapex dissolution, whereas it significantly increased the efficiency of solvents in dissolving a number of endodontic sealers.


Assuntos
Óxidos/química , Materiais Restauradores do Canal Radicular/química , Solventes/química , Clorofórmio/química , Silicatos/química , Compostos de Cálcio/química , Compostos de Alumínio/química , Cicloexanóis/química , Monoterpenos/química , Valores de Referência , Prata/química , Solubilidade , Fatores de Tempo , Titânio/química , Cimento de Óxido de Zinco e Eugenol/química , Bismuto/química , Teste de Materiais , Hidróxido de Cálcio/química , Salicilatos/química , Reprodutibilidade dos Testes , Análise de Variância , Combinação de Medicamentos , Resinas Epóxi/química , Ondas Ultrassônicas , Eucaliptol , Imersão
13.
Salud(i)ciencia (Impresa) ; 14(4): 204-208, jun. 2006. tab.
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1290552

RESUMO

The impact of low intensity, pulsed ultrasound on fracture healing is controversial. This review summarizes the authors' research on therapeutic ultrasound in fracture management. Our survey of orthopaedic surgeons and senior physiotherapy students found that use of therapeutic ultrasound is rare, due primarily to a perceived lack of evidence and lack of availability. There is evidence from randomized trials that low intensity ultrasound may significantly reduce the time to fracture healing, particularity in those fractures treated nonoperatively. The benefit of ultrasound following operativelymanaged fractures remains uncertain. Our economic analysis suggests that, from both governmental and societal perspectives, reamed intramedullary nailing is the treatment of choice for closed and open grade I tibial shaft fractures; however, there is evidence from a societal perspective that treatment of low energy tibial fractures with therapeutic ultrasound and casting may also be an economically-sound intervention. Larger trials are needed to resolve the role of therapeutic ultrasound in fracture healing


La relevancia que tiene un tratamiento con pulsos de ultrasonido de baja intensidad para la consolidación de las fracturas es controvertida. Esta revisión resume la investigación de los autores acerca de la terapia ultrasónica en el manejo de las fracturas. Nuestra encuesta de las creencias y las conductas de los cirujanos ortopedistas y de los estudiantes avanzados de fisioterapia encontró que la terapia ultrasónica es utilizada rara vez, debido fundamentalmente a que es vista como carente de pruebas en cuanto a sus beneficios y a que no es fácilmente accesible. Existen datos sugestivos tomados de ensayos aleatorizados de que el ultrasonido de baja intensidad podría reducir considerablemente el tiempo de consolidación de las fracturas, particularmente en el caso de aquellas tratadas incruentamente. Los beneficios del ultrasonido aplicado a las fracturas tratadas quirúrgicamente son aún inciertos. Nuestro análisis económico sugiere que, tanto desde la perspectiva gubernamental como desde la social, el enclavado endomedular fresado es el tratamiento de elección para las fracturas diafisarias de la tibia, tanto cerradas como expuestas tipo I; sin embargo, existen además hechos indicativos de que desde la perspectiva de la sociedad, el tratamiento de las fracturas tibiales de baja intensidad con reducción incruenta e inmovilización con yeso, en combinación con terapia ultrasónica, podría también ser una intervención económicamente beneficiosa. Se necesitan ensayos más grandes para dilucidar al papel que la terapia ultrasónica tiene en la consolidación de las fracturas


Assuntos
Ultrassom , Consolidação da Fratura , Fraturas Ósseas , Ondas Ultrassônicas , Fixação Intramedular de Fraturas , Imobilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...