Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.206
Filtrar
1.
Pesqui. bras. odontopediatria clín. integr ; 24: e220113, 2024. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1529140

RESUMO

Abstract Objective: To evaluate the effect of different pressures of an oral irrigation device (OID) and the irrigation solution type on the surface roughness of the giomer restorative material. Material and Methods: In this in vitro study, disk-shaped giomer samples were fabricated and assigned to 5 groups (n=23): Group 1, storage in distilled water (control); Group 2, OID #7 pressure/ water; Group 3, OID #10 pressure/ water; Group 4, OID #7 pressure/ 0.05% CHX; Group 5, OID #10 pressure/ 0.05% CHX. The samples' treatment simulated a one-year application of OID. Surface roughness (Ra) and topography of the giomer were evaluated using profilometry and scanning electron microscopy. The data were analyzed with Paired t-test, Tukey, and ANOVA tests (α=0.05). Results: The Ra of the samples increased significantly after treatment with OID (p<0.001). The roughness increase in groups with a pressure of 10 was higher than those with a pressure of 7 (p<0.001). The effect of pressure on surface changes was significant (p<0.001). However, the solution type and the cumulative effect of these two factors were insignificant (p=0.08 and p=0.43, respectively). Conclusion: Oral irrigation device with both solutions significantly increased the surface roughness and topographic changes of the giomer. The severity of these changes was related to the device's pressure.


Assuntos
Biguanidas , Água Destilada , Clorexidina/efeitos adversos , Resinas Compostas , Propriedades de Superfície , Técnicas In Vitro/métodos , Análise de Variância , Testes de Dureza/métodos
2.
Braz. dent. sci ; 27(1): 1-7, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1532450

RESUMO

Objective: The aim of this study was to determine if SEM used with imaging software could be used to quantitatively determine the extent of dentine roughness due to tooth-brushing. Material and methods: Flat, polished dentine surfaces were subjected to 25,000 cycles of simulated tooth-brushing at 2 strokes per second with a load of 200 g. At the end of the brushing cycle, dentine surfaces were first assessed using profilometry and then subjected to SEM analysis. Ra (average roughness) readings were obtained for profilometric assessment. Using imaging software, the horizontal distance between adjacent characteristic grooves noted on micrographs was measured, ensuring that the middle of each crest of the associated groove was used as the reference point, the Crest-to-Crest distance (C-C distance). These two parameters were examined statistically for correlation. Results: When Spearman Rank tests were utilized the correlation between average Ra and crest to crest measurements was 0.709 (p <0.01). The Bland Altman plot, however, showed poor agreement between the two test parameters. Conclusion: Further work is needed to validate the use of this methodology in the quantitative assessment of tooth surface loss due to abrasion (AU)


Objetivo: O objetivo deste estudo foi determinar se o MEV usado com software de imagem poderia ser usado para determinar quantitativamente a extensão da rugosidade da dentina devido à escovação dentária. Material e Métodos: Superfícies dentinárias planas e polidas foram submetidas a 25.000 ciclos de escovação dentária simulada a 2 movimentos por segundo com uma carga de 200g. No final do ciclo de escovação, as superfícies dentinárias foram primeiro avaliadas por perfilometria e depois submetidas à análise MEV. Leituras de Ra (rugosidade média) foram obtidas para avaliação perfilométrica. Utilizando um software de imagem, foi medida a distância horizontal entre sulcos característicos adjacentes observados nas micrografias, garantindo que o meio de cada crista do sulco associado fosse usado como ponto de referência, a distância crista a crista (distância CC). Esses dois parâmetros foram examinados estatisticamente para correlação. Resultados: Quando foram utilizados os testes de Spearman Rank, a correlação entre a média de Ra e as medidas de crista a crista foi de 0,709 (p<0,01). O gráfico de Bland Altman, no entanto, mostrou fraca concordância entre os dois parâmetros de teste. Conclusão: Mais trabalhos são necessários para validar o uso desta metodologia na avaliação quantitativa da perda da superfície dentária devido à abrasão(AU)


Assuntos
Propriedades de Superfície , Abrasão Dentária , Escovação Dentária , Microscopia Eletrônica de Varredura , Dentina
3.
RFO UPF ; 27(1)08 ago. 2023. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1511047

RESUMO

Objetivo: avaliar in vitro o polimento sobre resina acrílica quimicamente ativada (RAQA), por meio da rugosidade de superfície (Ra). Materiais e Método: Foram confeccionadas 40 amostras de RAQA, com dimensões de 10 a 10 x 2 mm, e foram divididas em quatro grupos (n=10): ausência do acabamento (AA); Ausência de polimento (AP); Polimento químico (PQ); Polimento com borrachas siliconadas + Escovas (PM). Os espécimes foram avaliados no quanto a rugosidade média (Ra) antes e após o envelhecimento em água destilada em uma estufa por 60 dias. Três medições de Ra (µm), na horizontal foram realizadas e calculada uma média para cada espécime. Os dados foram analisados de forma descritiva e inferencial, ANOVA de medidas repetidas e teste de Tukey com nível de significância de 5%. Resultados: Inicialmente, o grupo AA teve os menores valores de Ra e o grupo AP os maiores valores de rugosidade, com média e desvio padrão respectivamente 0,17 (±0,11) e 0,52 (±0,10). Após o envelhecimento, o grupo AA teve as menores médias e o grupo PQ os maiores valores de Ra, sendo 0,38 (±0,20) e 1,33 (±0,32), respectivamente. Os resultados evidenciaram diferença estatística significante quando as amostras foram submetidas ao acabamento com brocas. Conclusão: A RAQA necessita de polimento após acabamento com brocas, uma vez que a ausência de polimento comprometerá a lisura de superfície do material.(AU)


Objective: to evaluate in vitro polishing on chemically activated acrylic resin (RAQA), using surface roughness (Ra). Materials and Method: 40 RAQA samples were made, measuring 10 to 10 x 2 mm, and divided into four groups (n=10): absence of finishing (AA); Lack of polishing (AP); Chemical polishing (PQ); Polishing with silicone rubbers + Brushes (PM). The specimens were evaluated for their average roughness (Ra) before and after aging in distilled water in an oven for 60 days. Three horizontal Ra (µm) measurements were taken and an average was calculated for each specimen. Data were analyzed descriptively and inferentially, using repeated measures ANOVA and Tukey test with a significance level of 5%. Results: Initially, the AA group had the lowest Ra values and the AP group the highest roughness values, with mean and standard deviation respectively 0.17 (±0.11) and 0.52 (±0.10). After aging, the AA group had the lowest averages and the PQ group the highest Ra values, being 0.38 (±0.20) and 1.33 (±0.32), respectively. The results showed a statistically significant difference when the samples were finished with drills. Conclusion: RAQA requires polishing after finishing with drills, as the lack of polishing will compromise the surface smoothness of the material.(AU)


Assuntos
Resinas Acrílicas/química , Polimento Dentário/métodos , Valores de Referência , Elastômeros de Silicone , Propriedades de Superfície , Fatores de Tempo , Análise de Variância , Estudo de Avaliação
4.
RFO UPF ; 28(1): 38-49, 20230808. tab, ilus, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1509411

RESUMO

Objetivo: Este estudo teve como objetivo comparar a qualidade da obturação e a resistência de união de dois cimentos endodônticos, AH Plus e Bio-C Sealer, em dentes humanos e bovinos. Métodos: Os canais radiculares de 60 dentes unirradiculares [30 humanos (H) e 30 bovinos (B)] foram preparados e obturados por condensação lateral da guta-percha e AH Plus (grupos AP-H e AP-B) ou Bio-C Sealer (grupos BC-H e BC-B). Seis fatias de 1,5 mm de espessura foram obtidas de cada raiz. Os espécimes foram observados em estereomicroscópio para avaliar a qualidade da obturação, considerando possíveis espaços vazios no material obturador. Posteriormente, as fatias radiculares foram avaliadas em termos de resistência de união por push-out e modo de falha. Os dados foram analisados pelos testes de Mann-Whitney e coeficientes de correlação de Spearman (α=5%). Resultados: A qualidade de obturação fornecida por AP e BC foi semelhante em ambos os substratos de dentina. No entanto, ao comparar dentes humanos e bovinos, os escores de espaços vazios foram maiores nas amostras bovinas, para ambos os cimentos. AP teve maior resistência de união à dentina humana e bovina do que BC. No entanto, não houve diferença significativa na resistência de união entre os substratos dentinários, para ambos os cimentos testados. Além disso, houve uma correlação positiva e moderada entre os valores de resistência de união de dentes humanos e bovinos. O modo de falha misto foi o mais prevalente. Conclusão: AP e BC fornecem qualidade de obturação semelhante, mas o primeiro apresenta maiores valores de resistência de união à dentina humana e bovina. A utilização de dentes bovinos como substitutos de amostras humanas parece ser adequada em estudos relacionados à resistência de união, mas não naqueles que testam a qualidade da obturação endodôntica.(AU)


Objective: This study aimed to compare the filling quality and bond strength of two endodontic sealers, AH Plus and Bio-C Sealer, in human and bovine teeth. Methods: The root canals of 60 [30 human (H) and 30 bovine (B)] single-rooted teeth were prepared and filled by lateral condensation of gutta-percha and AH Plus (groups AP-H and AP-B) or Bio-C Sealer (groups BC-H and BC-B). Six 1.5-mm-thick slices were obtained from each root. The specimens were observed under a stereomicroscope to assess filling quality, considering possible voids within the filling material. Subsequently, root slices were evaluated in terms of push-out bond strength and failure mode. Data were analyzed by Mann-Whitney tests and Spearman correlation coefficients (α=5%). Results: The filling quality provided by AP and BC was similar in both dentin substrates. However, when comparing human and bovine teeth, void scores were greater in the bovine samples, for both sealers. AP had higher bond strength to human and bovine dentin than BC. However, there was no significant difference in bond strength between dentin substrates, for both sealers tested. Also, there was a positive and moderate correlation between the bond strength values of human and bovine teeth. The mixed failure mode was the most prevalent. Conclusion: AP and BC provide similar filling quality, but the first presents higher bond strength values to human and bovine dentin. The use of bovine teeth as substitutes for human samples seems adequate in studies related to bond strength, but not in those testing root canal filling quality.(AU)


Assuntos
Humanos , Animais , Bovinos , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Silicatos/química , Compostos de Cálcio/química , Resinas Epóxi/química , Valores de Referência , Propriedades de Superfície , Teste de Materiais , Cimentação/métodos , Estatísticas não Paramétricas , Falha de Restauração Dentária , Guta-Percha/química
5.
Rev. Flum. Odontol. (Online) ; 1(60): 45-55, jan.-abr. 2023.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1411271

RESUMO

Amplamente utilizados para substituir dentes perdidos, os implantes dentários nos últimos anos vêm apresentando tecnologias como superfícies com micro e nanotopografia e ajustes nas composições químicas, dentre outros, para melhorar a osseointegração e reduzir o prazo de tratamento, permitindo, assim, carga funcional imediata ou precoce em pacientes com densidade óssea reduzida. Vários métodos são aplicados com intuito de modificar a superfície do implante, como jateamento com areia, corrosão ácida, oxidação anódica, tratamento com flúor, usinagem, pulverização de plasma de titânio e revestimento de fosfato de cálcio; esses métodos podem aumentar notavelmente a área de superfície quando operada a técnica adequadada de modificação, quer por procedimento de adição ou subtração. Tais modificações promovem superfícies rugosas, as quais aumentam a porcentagem de contato osso-implante (BIC) durante o processo de cicatrização óssea inicial. Os principais benefícios da modificação da superfície são melhorar a molhabilidade (hidrofilicidade), adesão e fixação de células a implantes e proliferação celular. Dentre os tratamentos de superfície de implantes dentários destaca-se o jateamento de areia com granulação grossa e ataque-ácido com HCL/H2SO4 (SLA) em altas temperaturas, o revestimento de superfície do implante com hidroxiapatita, oxidação anódica e o duplo ataque ácido. O objetivo deste trabalho é realizar uma revisão de literatura discutindo a importância e eficácia desses métodos para a osseointegração e, por conseguinte, para a redução do período de tratamento.


Widely used to replace lost teeth, dental implants have been presenting technologies such as surfaces with micro and nano topography and adjustments in chemical compositions, among others, to improve osseointegration and reduce treatment time, thus allowing immediate or early functional load in patients with reduced bone density. Several methods are applied to modify the implant surface, such as sandblasting, acid corrosion, anodic oxidation, fluoride treatment, machining, titanium plasma spraying, and calcium phosphate coating; these methods can notably increase the surface area when the appropriate modification technique is operated, either by the addition or subtraction procedure. Such modifications promote rough surfaces, which increase the percentage of bone-implant contact (BIC) during the initial bone healing process. The main benefits of surface modification are to improve wettability (hydrophilicity), adhesion and attachment of cells to implants, and cell proliferation. Among the surface treatments for dental implants, sandblasting with large grit and acid-etching with HCL/H2SO4 (SLA) stands out at high temperatures. The surface coating of the implant with hydroxyapatite, anodic oxidation, and double acid-etching. This work aims to conduct a literature review discussing the importance and effectiveness of these methods for osseointegration and, therefore, for reducing the treatment period.


Assuntos
Propriedades de Superfície , Terapêutica , Implantes Dentários , Osseointegração
6.
Pesqui. bras. odontopediatria clín. integr ; 23: e210059, 2023. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1529136

RESUMO

ABSTRACT Objective: To identify the tobacco effect on flexural properties and the microhardness of three acrylic resins. Material and Methods: Three resins were tested: two thermo-polymerizable acrylic resins (RMB 20 and BMS 014) and one autopolymerized acrylic resin. The 3-point bending and microhardness tests were carried out with a universal tensile-compression machine and a micro-Vickers hardness tester. The acrylic resin specimens have been exposed for 21 days to cigarette smoke in a smoking room. Their mechanical strength was compared to unexposed samples. Statistical analysis was performed using the data processing software SPSS Statistics 21.0. Results: The flexural properties of the resins were affected by cigarette smoke only in the case of Major Base 20® (drop in strength with p= 0.02; 0.6; 0.7 and in elastic modulus with p= 0.86; 0.74 and 0.85 for Major Base 20®, BMS 014® and Major Repair®). The cigarette smoke affected significantly microhardness for all groups (p<0.001). Conclusion: Cigarette smoking does not affect the flexural properties of the acrylic resin (BMS 014® and Major Repair® unlike Major Base 20®), but it does reduce the microhardness.


Assuntos
Dentaduras , Fumar Cigarros/efeitos adversos , Resistência à Flexão , Propriedades de Superfície , Análise de Variância
7.
Braz. j. oral sci ; 22: e238637, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1512222

RESUMO

The objective of this study was to evaluate the effect of abrasion wear on surface roughness and microhardness of different commercially available resin composites simulating pH-challenges of the oral cavity. Methods: Three resin composites (RC) were used in this study: one conventional: Z250; and two bulk fill resin composites (BRC): Tetric N-Ceram (TNC) and Sonic Fill (SF). The RC was inserted in a prefabricated mold (15mm wide x 4mm thickness) in two layers, or in a single layer for BRC. Thirty samples were prepared and surface roughness (Ra) and Knoop microhardness (KHN) test were performed at three different time-points of evaluation: baseline (24h after sample preparation); partial (after pH cycling); and final (after simulated toothbrushing procedure). Two samples of each group were selected after different treatments and analyzed descriptively on a scanning electron microscopy (SEM). Data from Ra and KHN were analyzed by two-way repeated-measures ANOVA and Bonferroni's post-hoc test with a significance level set at 5%. Results: Ra increased for all groups (p<0.001), at the final time-point, Z250 and TNC groups present the highest values. Oppositely, KHN decreased for all groups (p<0.001), Z250 group showed the highest KHN values for all time-points (p<0.001). The SEM imagens showed a regular surface for samples cycled and irregular with inorganic particles exposed for samples toothbrushed. Conclusion: pH-cycling and simulated toothbrushing affected the superficial properties (roughness and Knoop microhardness), as observed at SEM imagens, with irregular surface with inorganic particles exposure


Assuntos
Propriedades de Superfície , Escovação Dentária , Microscopia Eletrônica de Varredura , Resinas Compostas
8.
Rev. odontol. UNESP (Online) ; 52: e20230021, 2023. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1530303

RESUMO

Introdução: A importância da rugosidade para a osseointegração se dá pela correlação das interações das proteínas com a superfície do implante, a adsorção. Diferentes métodos são utilizados nos tratamentos de superfície, em que ocorre a remoção de partes da camada superficial, como o ataque ácido. Objetivo: Analisar as alterações de rugosidade na superfície dos implantes osseointegrados tratadas por duplo ataque ácido com uso único e até quatro reutilizações dos ácidos. Material e método As amostras de implantes dentários de liga de titânio (SINGULAR Implants ®) (n = 10) foram subdividas em cinco grupos: controle, tratamento 1, 2, 3 e 4, conforme as reutilizações dos ácidos. As capturas dos implantes no aumento de 500x, 1000x, 2000x e 4000x foram realizadas no microscópio eletrônico de varredura, para posterior análise de rugosidade pelo software ImageJ. Os valores de Ra e Rq foram analisados estatisticamente pelo teste ANOVA e o pós-teste de Tukey. Resultado: Os dados obtidos pelas imagens capturadas e pelos números de Ra e Rq adquiridos pelo ImageJ demonstraram que o tratamento com o duplo ataque ácido com cinco utilizações dos mesmos ácidos foi positivo para o tratamento de superfície do implante de liga de titânio. Conclusão: Pode-se concluir que até quatro reutilizações dos ácidos não interferiu estatisticamente nos valores de rugosidade em diferentes aumentos. São necessários mais estudos referentes à reutilização dos ácidos, contribuindo para a diminuição dos custos aos fabricantes, aumentando a sustentabilidade e mantendo-se a qualidade do produto.


Introduction: The importance of roughness for osseointegration is due to the configuration of proteins with the surface of the implant, and adsorption. Different methods are used in surface treatments, in which parts of the surface layer are removed, such as acid attack. Objective: To analyze changes in roughness on the surface of osseointegrated implants treated by double acid etching with single-use and up to 4 reuses of serums at a magnification of 500x, 1000x, 2000x, and 4000x in the scanning microscope (SEM). Method Samples of adherent implants (SINGULAR Implants ®) of lever alloy (n=10) were subdivided into 5 groups: control, treatment 1, 2, 3, and 4, according to the reuses. For the surface topography of the samples, SEM was used, followed by analysis by ImageJ software. Using the ANOVA test and Turkeys post-test, Ra and Rq values were statistically analyzed. Result: The data obtained both by the images captured in the SEM and by the Ra and Rq numbers acquired by the ImageJ illustrate that the treatment with the double acid attack with 5 uses of the same ones served, was positive for the surface treatment of the alloy implant of independent. Conclusion: It can be concluded that up to four reuses of food do not statistically interfere with roughness values. More studies are needed regarding the reuse of acids, certainly to reduce costs to manufacturers, increasing sustainability while maintaining product quality.


Assuntos
Propriedades de Superfície , Titânio , Implantes Dentários , Análise de Variância , Osseointegração , Adsorção , Microscopia Eletrônica de Varredura
9.
Braz. dent. sci ; 26(3): 1-9, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1442905

RESUMO

Objetivo: Este estudo avaliou as propriedades de polimento dos materiais de splint oclusal obtidos usando métodos de fabricação subtrativos e aditivos com os procedimentos de polimento laboratorial (LP) e polimento em consultório (CP). Material e Métodos: As amostras (N=180, n=60 para cada grupo) foram fabricadas usando um dos seguintes métodos: método de fabricação subtrativo (SMM) (M-PM Disc, Merz Dental GmbH), método de fabricação aditivo (AMM) (Freeprint Splint 2.0, DETAX GmbH & Co. KG) e o método de fabricação convencional (CMM) (Promolux HC, Merz Dental GmbH). Seguindo os procedimentos de LP e CP, a rugosidade da superfície dos espécimes foi medida usando um perfilômetro de superfície digital. Um espécime representativo foi selecionado de cada grupo, e uma imagem de microscópio eletrônico de varredura (SEM) foi obtida. Resultados: Tanto o método de fabricação quanto os procedimentos de polimento afetaram significativamente os resultados (P<0,01). Os termos de interação também foram significativos (P<0,001). Conclusão: Com ambos os métodos de polimento, a rugosidade superficial do grupo AMM foi a maior e a do grupo CMM a menor. Embora o procedimento CP tenha sido mais eficaz do que LP com ambos os métodos, a rugosidade da superfície ficou abaixo do limite de 0,2 µm após ambos os procedimentos de polimento testados (AU)


Objective: This study evaluated the polishing properties of the occlusal splint materials obtained using subtractive and additive manufacturing methods with the laboratory-type polishing (LP) and chairside-type polishing (CP) procedures. Material and Methods: Specimens (N=180, n=60 each group) were manufactured using one of the following methods: subtractive manufacturing method (SMM) (M-PM Disc, Merz Dental GmbH), additive manufacturing method (AMM) (Freeprint Splint 2.0, DETAX GmbH & Co. KG), and the conventional manufacturing method (CMM) (Promolux HC, Merz Dental GmbH). Following LP and CP procedures, surface roughness of the specimens was measured using a digital surface profilometer. One representative specimen was selected from each group, and a scanning electron microscope (SEM) image was made. Results: Both the manufacturing method and the polishing procedures significantly affected the results (P<0.01). Interaction terms were also significant (P<0.001). Conclusion: With both polishing methods, surface roughness of the AMM group was the highest and the CMM group the least. Although the CP procedure was more effective than LP with both methods, surface roughness was below the 0.2 µm threshold after both polishing procedures tested. (AU)


Assuntos
Propriedades de Superfície , Placas Oclusais , Desenho Assistido por Computador , Polimetil Metacrilato , Materiais Dentários
10.
Araçatuba; s.n; 2023. 44 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1510490

RESUMO

Atualmente novos princípios ativos de função reabsortiva têm ganhado campo de estudo para avaliar seus mecanismos e comportamento biológico. Com isso, um novo antirreabsortivo, inibidor da catepsina K tem apresentado efeito positivo na osseointegração. Este estudo tem como objetivo avaliar a resposta óssea da superfície de implantes revestida por duplo ataque ácido e Odanacatib (MK-0822) em ratas ovariectomizadas. Neste estudo foram utilizadas ratas (Albinus, Wistar) ovariectomizadas ou sham (placebo). Cinquenta e dois (52) tiveram as superfícies revestidas por duplo ataque ácido e MK-0822 a 0,06 mg/ml através do método biomimético, e 48 implantes foram instalados em tíbias de ratas ovariectomizadas ou sham. Microscopia eletrônica de varredura (MEV) e energia dispersiva de raios-x (EDS) foram realizadas em 4 implantes após tratamento de superfície, para análise da topografia e composição química, além da realização da análise do ângulo de contato em 16 discos de titânio comercialmente puro tratados com as mesmas superfícies. Aos 15 e 40 dias após instalação de implantes (n=6), foi realizada microtomografia computadorizada. Dados quantitativos foram avaliados adotando-se o nível de significância p< 0,05. Além dos resultados topográficos favoráveis para os grupos tratados com MK-0822, os resultados microtomográficos apresentaram diferença estatisticamente significante entre os grupos SHAM e OVX na maioria dos parâmetros (p< 0,05). Ainda assim, os grupos tratados com MK-0822 apresentaram resultado semelhante ou maior, porém sem diferença estatística, em relação ao grupo controle em todos os parâmetros (TV, BV, BV ̸TV, Tb.Sp e Tb.N)(AU)


Currently new active principles of resorptive function have gained field of study to evaluate their mechanisms and biological behavior. Thereby a new anti-absorbent, cathepsin K inhibitor has had a positive effect on osseointegration. This study aims to evaluate the bone response of the surface of implants coated by double acid-etched and Odanacatib (MK-0822) in ovariectomized rats. In this study, either ovariectomized rats (Albinus, Wistar) or sham (placebo) have been used. Fifty-two (52) implants had the surfaces coated with double acid-etched and MK-0822 at 0,06 mg/ml by the biomimetic method and 48 implants were installed on sham or ovariectomized rat tibias. Scanning electron microscopy (SEM) and X-ray dispersive energy (EDS) were performed in 4 implants after surface treatment for analysis of topography and chemical composition, in addition to performing contact angle analysis on 16 commercially pure titanium discs treated with the same surfaces. At 15 and 40 days after implant installation, microcomputer tomography was performed. Quantitative data was evaluated by adopting the significance level of p< 0.05. Besides the favorable topographic results to MK-0822 coated implants group, the microtomographic results presents statistically significant differences between the SHAM and OVX groups at most of the parameters (p< 0,05). Nevertheless, the MK-0822 coated group presents similar or higher values, although without statistic differences related to the control group in all parameters (TV, BV, BV ̸TV, Tb.Sp and Tb.N)(AU)


Assuntos
Animais , Ratos , Propriedades de Superfície , Reabsorção Óssea , Implantes Dentários , Ratos Wistar , Catepsina K
11.
Braz. j. oral sci ; 21: e224265, jan.-dez. 2022. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1354719

RESUMO

Aim: This study assessed the color and translucency stability of a polymer infiltrated ceramic network (PICN) and compared it with a resin composite (RC) and a feldspathic ceramic (FEL). Methods: Disc-shaped samples of a PICN (Vita Enamic), a feldspathic ceramic (Vitablocks Mark II), and a resin composite (Brava block) were prepared from CAD/CAM blocks. PICN and RC surfaces were finished with a sequence of polishing discs and diamond paste. FEL samples received a glaze layer. The samples were subjected to 30-min immersions in red wine twice a day for 30 days. CIEL*a*b* coordinates were assessed with a spectrophotometer at baseline and after 15 and 30 days of immersion. Color alteration (ΔE00) and translucency parameter (TP00) were calculated with CIEDE2000. Average roughness was measured before the staining procedures. Color difference and translucency data were analyzed with repeated-measures ANOVA and Tukey's tests. Roughness was analyzed with the Kruskal-Wallis test. Results: Roughness was similar among the experimental groups. All materials had their color alteration significantly increased from 15 to 30 days of staining. PICN reached an intermediate ΔE00 between FEL and RC at 15 days. PICN revealed a color alteration as high as the composite after 30 days. No statistical difference was observed regarding translucency. Conclusion: PICN was not as color stable as the feldspathic ceramic at the end of the study. Its color alteration was comparable to the resin composite when exposed to red wine. However, the translucency of the tested materials was stable throughout the 30-day staining


Assuntos
Propriedades de Superfície , Teste de Materiais , Cerâmica , Desenho Assistido por Computador , Cor , Resinas Compostas
12.
J. oral res. (Impresa) ; 11(5): 1-12, nov. 23, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1435341

RESUMO

In Purpose: The fabrication technique can influence the mechanical properties of Cobalt-Chromium (Co-Cr) dental alloys. Hence, the present study aims to determine the corrosion resistance and thermal expansion of alloys manufactured using three contemporary techniques. Material and Methods: A total of nine specimens of Co-Cr alloy were prepared according to ISO 22674 by each one of the three manufacturing processes (three in each process); conventional casting, direct metal laser sintering (DMLS) and milling (MIL). All these specimens were tested for coefficient of thermal expansion and corrosion resistance. The data was tabulated and analyzed statistically. Results: The difference in the thermal expansion of alloys fabricated using three techniques was non-significant at almost all the temperatures from 50 ºC to 950 ºC (p>0.05), except 450 ºC and 600 °C. The polarization resistance of specimens manufactured using the conventional method was more compared to DMLS and MIL at pH 5 (Conventional>MIL>DMLS) (p<0.001). Conclusion: The thermal expansion behavior of alloys manufactured using the three selected techniques were similar, whereas, at acidic pH, the corrosion resistance of conventional and MIL were better than the DMLS.


Antecedentes: La técnica de fabricación puede influir en las propiedades mecánicas de las aleaciones dentales de cobalto-cromo (Co-Cr). Por lo tanto, el presente estudio tiene como objetivo determinar la resistencia a la corrosión y la expansión térmica de aleaciones fabricadas con tres técnicas contemporáneas. Material y Métodos: Se prepararon un total de nueve probetas de aleación de Co-Cr según ISO 22674 por cada uno de los tres procesos de fabricación (tres en cada proceso); fundición convencional, sinterización directa de metal por láser (DMLS) y fresado (MIL). Todos estos especímenes fueron probados para determinar el coeficiente de expansión térmica y la resistencia a la corrosión. Los datos fueron tabulados y analizados estadísticamente. Resultados: La diferencia en la dilatación térmica de las aleaciones fabricadas con las tres técnicas no fue significativa en casi todas las temperaturas desde 50ºC hasta 950ºC (p>0,05), excepto 450ºC y 600ºC. La resistencia a la polarización de las muestras fabricadas con el método convencional fue mayor en comparación con DMLS y MIL a pH 5 (Convencional>MIL>DMLS) (p<0, 0 01). Conclusión: El comportamiento de expansión térmica de las aleaciones fabricadas con las tres técnicas seleccionadas fue similar, mientras que, a pH ácido, la resistencia a la corrosión de la convencional y la MIL fue mejor que la de la DMLS.


Assuntos
Humanos , Temperatura , Ligas de Cromo , Corrosão , Ligas Dentárias , Propriedades de Superfície , Técnicas In Vitro , Cromo/química , Cobalto/química , Lasers
13.
Rev. ADM ; 79(5): 284-291, sept.-oct. 2022. tab
Artigo em Espanhol | LILACS | ID: biblio-1428520

RESUMO

Introducción: se realizó una revisión bibliográfica con el objetivo de conocer, analizar y comparar los diferentes tipos de adhesivos de octava generación que se encuentran en el mercado y la diferencia que existe entre cada uno. Los adhesivos universales han demostrado mejoras en su resistencia, sobre todo en las técnicas de aplicación y en las propiedades de estos materiales, al mejorar la fuerza adhesiva para que el odontólogo pueda brindar tratamientos restaurativos exitosos. Objetivo: conocer, analizar y comparar los diferentes tipos de adhe- sivos de la octava generación empleados en odontología. Material y métodos: se realizó una búsqueda en las bases de datos electrónicas PubMed, BVS, Redalyc y ScienceDirect. Se utilizaron 32 artículos que cumplieron con los criterios predeterminados y la especificidad reque- rida para la pregunta de investigación. Conclusiones: se demostró que la tecnología cada día avanza, sobre todo en el área de los adhesivos, ya que éstos son de mucha utilidad en el día a día del odontólogo; es importante conocer cada uno de éstos, puesto que es un poco complejo seleccionar el correcto, mas no el uso. En la actualidad, existen diversas opciones por las que el odontólogo puede optar, es por ello que el pro- fesional debe estar capacitado sobre cada una de las diferentes marcas existentes y, de acuerdo al tratamiento, debe elegir cuál es mejor utilizar en una rehabilitación. Es importante para el odontólogo conocer estos materiales, ya que esto lo beneficiará al momento de llevar un plan de tratamiento restaurador (AU)


Introduction: a bibliographic review was carried out to learn about, analyze, and compare the different types of eighth-generation adhesives on the market and the difference between each one. Universal adhesives have demonstrated improvements in their resistance, especially in the application techniques and properties of these materials, improving the adhesive strength so that the dentist can provide successful restorative treatments. Objective: to know, analyze and compare the different types of eighth-generation adhesives used in dentistry. Material and methods: a search was made of the following electronic databases: PubMed, BVS, Redalyc, ScienceDirect. Finally, 32 articles that met the predetermined criteria and the specificity required for the research question were used. Conclusions: it was demonstrated that technology is advancing every day, especially in the area of adhesives since these are very useful in the daily life of the dentist. It is important to know each one of these since it is a little complex at the moment of selecting the correct one, but not the use. Currently, there are several options that the dentist can choose, which is why the professional must be trained on each of the various existing brands and according to the treatment which is the best to use at the time of rehabilitation. The dentist needs to know these materials since they will benefit him/her when carrying out a restorative treatment plan (AU)


Assuntos
Tecnologia Odontológica/tendências , Adesivos Dentinários , Propriedades de Superfície , Condicionamento Ácido do Dente/métodos , Força Compressiva , Esmalte Dentário/efeitos dos fármacos , Resistência ao Cisalhamento , Dentina/efeitos dos fármacos , Nanopartículas , Resistência à Flexão
14.
São Paulo; s.n; 20220720. 185 p.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1379715

RESUMO

O desgaste dentário é um processo de perda de estrutura dental, de etiologia multifatorial, com incidência crescente na população e ocasionado, principalmente, pela frequência do contato da superfície dentária com substâncias químicas e mecânicas, resultantes da alimentação e de hábitos orais. Os efeitos da ação dos desafios químicos e/ou mecânicos no dente, hígido ou restaurado, podem variar conforme as propriedades e características do substrato dentina, material restaurador. O estudo objetivou analisar os efeitos dos desafios erosivo (DE) e erosivo-abrasivo (DEA) na superfície de diferentes materiais restauradores (MR), sistemas adesivos (SA) e da dentina adjacente às restaurações (DAR). Molares humanos hígidos (n=75) foram limpos e preparados até obtenção de dentina oclusal uniforme. Os espécimes foram aleatoriamente divididos em 5 grupos (n=15). Na superfície dentinária, uma cavidade 4 x 2 mm foi confeccionada por meio de uma ponta diamantada, e restaurada por diferentes tipos de SR: Amaris® (AMA), Beautifil® II (BEA), ClearfilTM SE Bond 2 (CFB), FL-Bond II (FLB) e RIVA Self Cure (RIVA). Após restauração, a superfície do espécime foi delimitada em três partes duas, nas extremidades, que foram protegidas por fita adesiva anticorrosiva, e uma, intermediária (2 mm), que foi deixada livre para exposição da área aos desafios. No DE, o espécime foi imerso em solução de ácido cítrico 1% (pH 2.3) por dois min, seguido de imersão em saliva artificial por 60 min. Esse ciclo foi realizado durante 5 dias (6x/dia). No DEA, os espécimes foram submetidos ao mesmo DE descrito, porém foram escovados em máquina de escovação (escova macia, 45 ciclos/150g/15s), 2x/dia (após 30 min do primeiro e do último ciclo erosivo do dia). Os efeitos dos desafios foram avaliados pela análise das propriedades de perda de superfície (PS, m) e rugosidade superficial (RS, m) (Perfilometria óptica); e dureza superficial (HB, nanoindentação, Kg/mm2). Os dados foram analisados estatisticamente (p=0.05) pelos testes ANOVA, de Tukey e pela Correlação Linear de Pearson. Após desafios, as DAR de todos os grupos apresentaram elevada perda e diminuição na dureza. O DE ocasionou maior PS na dentina (PS>20 m). Não houve diferença entre a rugosidade dos materiais restauradores após desafios. O material RIVA apresentou elevada perda (PS>2 m), elevada rugosidade (RS=0.93048±0.2) e diminuição na dureza (HB<35 Kg/mm2) após desafios, principalmente após escovação. A rugosidade dentinária de AMA+CFB (RS=0.61921±0.1) foi menor após abrasão. Os desafios agiram igualmente sobre a dureza da interface adesiva. A dureza da interface de BEA+FLB (HB=16.97627±2.32) foi menor após escovação. Após erosão, a dureza dos materiais bioativos BEA, FLB e RIVA reduziram. Os efeitos observados dependeram do tipo de desafio e substrato envolvido no processo. A ação isolada do ácido cítrico foi mais agressiva no substrato dentinário. Os desafios tiveram efeitos sobre as propriedades dos materiais restauradores, principalmente nas dos bioativos. Nenhum material foi eficaz contra a desmineralização severa da dentina.


Assuntos
Propriedades de Superfície , Abrasão Dentária , Desgaste dos Dentes
15.
Pesqui. bras. odontopediatria clín. integr ; 22: e210120, 2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1422283

RESUMO

Abstract Objective: To examine the cyclic fatigue resistance and surface topography of TruNatomy and ProTaper Gold nickel-titanium rotary files and evaluate the presence of alterations to surface topography following instrumentation in simulated curved canals. Material and Methods: Twenty-four nickel-titanium instruments, twelve each of TN and PTG file systems, were evaluated for cyclic fatigue resistance. The rotary files were rotated in a simulated root canal with standardized diameter, angle of curvature, and radius of curvature in a custom-made cyclic fatigue testing device until the instrument fracture occurred. The time to fracture for each instrument was recorded with a stopwatch; in seconds in each group. Fractured instruments were subjected to atomic force microscopy analysis measuring the average roughness and the root mean square values to investigate surface features of endodontic files. Mean values and standard deviation were calculated. Data were analyzed using the Mann-Whitney U test. Results: Time to fracture was marginally higher in PTG instruments than in the TN file systems. PTG files exhibited higher surface roughness when compared with TN files (p<0.05). Conclusion: TN file system had a higher cyclic fatigue resistance than PTG. Cyclic fatigue causing file breakage did affect the surface topography of the files. PTG files showed a higher surface porosity value than the TN files (AU).


Assuntos
Titânio/química , Microscopia de Força Atômica/instrumentação , Ligas Dentárias , Instrumentos Odontológicos , Endodontia , Propriedades de Superfície , Estatísticas não Paramétricas , Cavidade Pulpar , Testes de Dureza , Níquel/química
16.
Braz. oral res. (Online) ; 36(Jun): e082, 2022.
Artigo em Inglês | LILACS, BNUY-Odon, BNUY | ID: biblio-1372593

RESUMO

Abstract The objective of the present study was to evaluate the effect of irradiance and radiant exposure on the chemical-mechanical properties of a resin composite. A micro-hybrid resin composite (Clearfil AP-X, Kuraray) was investigated under two different irradiances: low (300 mW/cm2) and high (800 mW/cm2) and radiant exposures: 8 and 16 J/cm2. Four groups, named Low 8 J/cm2, High 8 J/cm2, Low 16 J/cm2, and High 16 J/cm2 were tested, and their flexural strengths, elastic moduli, depths of cure, and degrees of conversion were evaluated. Data were analyzed using two-way ANOVA and Tukey's test. A multiple linear regression model was used to correlate the irradiance and radiant exposure with dependent variables (α = 0.05). Irradiance and radiant exposure were found statistically significant for all dependent variables. The interaction between the factors was statistically significant only for the degree of conversion and elastic modulus. Group Low 16 J/cm2 exhibited a significantly superior performance in all the evaluated properties. Barring the degree of conversion, no significant differences were observed among the properties evaluated between the Low 8 J/cm2 and High 8 J/cm2 groups. The adjusted R2 values were high for the depth of cure and degree of conversion (0.58 and 0.96, respectively). Both irradiance and radiant exposure parameters play an important role in establishing the final properties of a micro-hybrid resin composite. Irradiance has a greater influence under higher radiant exposures.


Assuntos
Teste de Materiais , Resinas Compostas , Materiais Dentários , Luzes de Cura Dentária , Polimerização , Resistência à Flexão , Propriedades de Superfície
17.
Pesqui. bras. odontopediatria clín. integr ; 22: e210044, 2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1365224

RESUMO

ABSTRACT Objective To assess the effects of coloring beverages on the color stability of two types of hybrid ceramics with different surface treatments. Material and Methods 180 specimens of two hybrid ceramics (Vita Enamic and Mazic Duro) and a feldspathic ceramic (Vita Mark II) were prepared (n=60 in each group). Half of the discs in each group were glazed while the other was polished. The specimens were then divided into three subgroups and immersed in distilled water, carrot juice, and coffee. The overall color difference (∆E) was calculated based on CIE L*a*b* color space. Data were analyzed using three-way and one-way ANOVA; Tukey's honest significant difference was also done for pairwise comparisons (α=0.05). Results Vita Mark II specimens revealed less overall color changes compared to other groups. The ∆E of the glazed Vita Enamic specimens was greater than polished specimens following immersion in distilled water (p=0.03) and coffee (p=0.001), but it was not significant for carrot juice. The same results were obtained for polished Mazic Duro specimens. Relatively similar amounts of ∆E were recorded in polished and glazed subgroups of Vita Mark II. Conclusion The ∆E of hybrid ceramics was higher than Vita Mark II. Polishing could be recommended for surface treatment of hybrid ceramics instead of glazing, saving time and facilitating the process.


Assuntos
Espectrofotometria/instrumentação , Propriedades de Superfície , Bebidas , Cor , Cimentos Dentários , Água Destilada , Cerâmica , Análise de Variância , Prótese Dentária , Desenho Assistido por Computador/instrumentação , Café , Porcelana Dentária , Corantes , Sucos de Frutas e Vegetais , Irã (Geográfico)/epidemiologia
18.
Braz. j. oral sci ; 20: e213736, jan.-dez. 2021. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1253012

RESUMO

Although Spondias mombin L. extract has an excellent antimicrobial effect against oral microorganisms, it should be clarified how it affects enamel surface properties. Aim: To evaluate the color change, wettability/contact angle, surface roughness and morphology of bovine enamel submitted to the Spondias mombin L. extract. Methods: Thirty bovine teeth were distributed into the following groups: 0.12% chlorhexidine digluconate, 1:32 Spondias mombin L. extract and distilled water. Color change (CC) was evaluated after immerging specimens into the solutions for 14 days. Surface roughness (Ra) was measured using a roughness meter; wettability/contact angles (CA) were determined by the sessile drop method, and scanning electron microscopy images were obtained to characterize the morphology (SMA). The pH of the solutions was evaluated using a pHmeter. The Ra, CA, and CC data were parametric (Kolmogorov-Smirnov; p>0.05). Two-way ANOVA (for Ra and CA) and one-way ANOVA (for CC) with Tukey's posthoc tests at a significance level of 5% were used. SMA was analyzed descriptively. Results: The Spondias mombin L. extract revealed an acidic pH, and when in contact with the bovine teeth, it increased the wettability, but it did not cause statistically significant differences in the Ra. Spondias mombin L. extract caused the highest color change. The SEM images showed differences in the specimens' surface submitted to the extract compared to the other groups. Conclusion: Spondias mombin L. extract provided negative effects on bovine enamel's surface, including a high color change and a more wettable substrate


Assuntos
Animais , Bovinos , Propriedades de Superfície , Anacardiaceae , Esmalte Dentário , Fitoterapia , Antissépticos Bucais
19.
Braz. j. oral sci ; 20: e211670, jan.-dez. 2021. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1254259

RESUMO

Aim: To evaluate the effect of different surface treatments and adhesive approaches on the microshear bond strength of resin cement to a polymer-infiltrated ceramic network (PICN). Methods: PICN blocks were randomly assigned into 9 groups (n=10): CTRL: no treatment; HF: 5% hydrofluoric acid etching; HF-S: HF + silane; HF-S-A: HF-S + adhesive (Adper Single Bond 2); HF-UA: HF + universal adhesive (Single Bond Universal); SB: sandblasting with 50 µm Al2O3 particles; SB-S: SB + silane; SB-S-A: SB-S + adhesive; SB-UA: SB + universal adhesive. Resin cement microcylinders (Ø = 0.96 mm; height = 1 mm) (RelyX Ultimate) were built upon the PICN surface after roughness and contact angle measurements. Next, microshear bonding tests (µSBS) were performed (0.5 mm/min) after water storage (37ºC, 90 days) and thermocycling (12,000 cycles; 5ºC-55ºC). Failure modes were observed under stereomicroscope. Bond strength data were analyzed by two-way ANOVA/Tukey's test and t-tests. Kruskal-Wallis/Dunn's tests were conducted for roughness and contact angle data (α = 0.05). Results: A rougher surface and lower contact angles were observed for Sandblasting. HF-S (18.54 ± 2.03 MPa), SB-S (19.00 ± 1.66 MPa) and SB-UA (18.07 ± 2.36 MPa) provided the highest bond strength values, followed by the other treated groups. The CTRL group resulted in lower bond strength (7.18 ± 2.34 MPa). Conclusion: Hydrofluoric acid etching followed by silane application and sandblasting followed by silane or universal adhesive are useful clinical steps to enhance bonding to PICN. Adhesive applications after HF etching have no advantages in bonding to PICN


Assuntos
Propriedades de Superfície , Cerâmica , Adesivos Dentinários , Cimentos de Resina , Abrasão Dental por Ar , Ácido Fluorídrico
20.
Braz. dent. j ; 32(4): 96-105, July-Aug. 2021. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1345515

RESUMO

Abstract This study evaluated the effect of post-cure heat treatment (PCHT) on the Knoop microhardness (KHN), degree of conversion (DC), color changes, and contrast ratio (CR) of four resin composites (RCs): Z100 (3M ESPE), Z350 XT (3M ESPE), Estelite Omega (Tokuyama) and Empress Direct (Ivoclar Vivadent). Specimens (12 × 1 mm) were prepared for each material (n = 10 / group). After curing, samples were subjected to PCHT for 10 min at 100°C or 170°C. Control group was maintained at room temperature (24°C) for the same time. The DC was analyzed by FT-NIR immediately and 24 h after the PCHT (n = 3 / group). KHN was analyzed 24 h after PCHT (n = 10 / group). According to CIEDE2000 (∆E00), color measurements were obtained immediately after curing, five minutes after PCHT, and after seven days of storage in water, coffee, and red wine. Data were analyzed by One and Two-Way ANOVA (p < 0.05). Z100, Z350, and Estelite Omega showed increases in KHN with increased temperature (p < 0.05). PCHT at 100°C and 170°C led to a higher DC of all RCs (p < 0.05). Initially, the PCHT lead to increased ∆E00 values (p < 0.05), which was decreased after immersion in coffee and wine (p < 0.05). Considering the effect of PCHT and staining solutions, lower color changes were observed in the thermally treated specimens (p < 0.05). Taken collectively, the results suggest the PCHT as an economical and practical alternative to enhance direct RC's properties in direct-indirect and indirect restorations.


Resumo Este estudo avaliou o efeito do tratamento térmico pós-cura (PCHT) na microdureza Knoop (KHN), grau de conversão (DC), mudanças de cor e razão de contraste (CR) de quatro compósitos resinosos (RCs): Z100 (3M ESPE ), Z350 XT (3M ESPE), Estelite Omega (Tokuyama) e Empress Direct (Ivoclar Vivadent). Corpos de prova (12 × 1 mm) foram preparadas para cada material (n = 10 / grupo). Após a cura, as amostras foram submetidas ao PCHT por 10 min a 100 ou 170° C. O grupo controle foi mantido à temperatura ambiente (24° C) pelo mesmo tempo. O DC foi analisada por FT-NIR imediatamente e 24 h após a PCHT (n = 3 / grupo). KHN foi analisado 24 h após PCHT (n = 10 / grupo). De acordo com o CIEDE2000 (∆E00), as medidas de cor foram obtidas imediatamente após a cura, cinco minutos após a PCHT e após sete dias de armazenamento em água, café e vinho tinto. Os dados foram analisados por ANOVA de um e dois fatores (P < 0,05). Z100, Z350 XT e Estelite Omega mostraram aumentos no KHN com o aumento da temperatura (P < 0,05). PCHT a 100 ° C e 170 ° C levou a uma maior DC de todos os RCs (P < 0,05). Inicialmente, o PCHT levou ao aumento dos valores de ∆E00 (P < 0,05), que diminuiu após a imersão em café e vinho (P < 0,05). Considerando o efeito de PCHT e soluções de coloração, menores mudanças de cor foram observadas nas amostras tratadas termicamente (P < 0,05). Os resultados sugerem o PCHT como uma alternativa econômica e prática para aumentar as propriedades diretas de compósitos resinosos em restaurações diretas-indiretas e indiretas.


Assuntos
Resinas Compostas , Temperatura Alta , Propriedades de Superfície , Teste de Materiais , Café
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...