Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 916
Filtrar
1.
Zhonghua Yan Ke Za Zhi ; 60(4): 352-358, 2024 Apr 11.
Artigo em Chinês | MEDLINE | ID: mdl-38583059

RESUMO

Objective: To investigate the differences in reading efficiency and visual fatigue between the use of augmented reality (AR) glasses and laptops. Methods: A prospective self-controlled study was conducted. Healthy students from Capital Medical University who frequently engaged in long-term near work and used laptops and other digital display devices were recruited as subjects at Beijing Tongren Hospital, Capital Medical University between November 1 and November 15, 2023. LogMAR visual acuity, visual functions (accommodation, convergence, and fusion), and visual fatigue scores (Likert visual fatigue scale) of the participants were assessed. The order of using the laptop and AR glasses for each participant was determined by a coin toss. Reading efficiency (reading speed and error rate multiplied by the detection rate of incorrect numbers) with different devices for 10 minutes at the same time on different dates and visual fatigue scores after watching a 20-minute video were measured. Statistical analyses were performed using paired t-tests and Wilcoxon signed-rank tests. Results: A total of 20 eligible subjects were included, comprising 7 males and 13 females, with a mean age of (25.45±2.27) years. There was no significant change in binocular visual acuity before and after using AR glasses and laptops (both P>0.05). The reading speed and reading efficiency of using AR glasses [(34.03±9.25) and (29.19±7.62) digits/min, respectively] were significantly lower than those of using laptops [(39.43±10.36) and (35.67±9.87) digits/min, respectively] (t=4.36, P<0.001), while the difference in error detection rate was not statistically significant (t=1.29, P=0.213). There was no statistically significant difference in visual fatigue scores before watching videos with the two devices (Z=-0.71, P=0.480). However, the visual fatigue score after watching videos with AR glasses [(20.55±5.04) points] was significantly higher than that with laptops [16.50 (13.00, 19.75) points] (Z=-2.85, P=0.004). The visual fatigue scores after watching videos with both devices were significantly higher than before (P<0.05), with a more significant increase observed with AR glasses [(6.05±3.50) points] (Z=-3.41, P<0.001). Conclusion: Compared with using laptops, the reading speed and efficiency were lower, and the visual fatigue was more pronounced with the use of AR glasses at the current technical level. Further optimization and improvement of AR glasses are warranted.


Assuntos
Astenopia , Realidade Aumentada , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Estudos Prospectivos , Acuidade Visual , Visão Ocular
2.
Zhonghua Yan Ke Za Zhi ; 60(4): 322-329, 2024 Apr 11.
Artigo em Chinês | MEDLINE | ID: mdl-38583055

RESUMO

Asthenopia is a group of eye discomfort syndromes with complex clinical manifestations, accompanied with systemic symptoms or not. It is caused by diverse influencing factors and occurs upon overuse of the eyes. Over the past decade, significant changes have appeared in the etiology, clinical manifestation and treatment of asthenopia with great changes in the society and lifestyles. The Chinese Optometric Association of Chinese Ophthalmological Society and the Optometry Group of Chinese Ophthalmologist Association have organized nationwide experts in the field to thoroughly discuss the latest researches on asthenopia. Consensus opinions have been formed on the causes, influencing factors, clinical manifestations, diagnosis and treatment of asthenopia, following the definition of asthenopia in the International Classification of Diseases, so as to provide guidance for the clinical diagnosis and treatment of asthenopia.


Assuntos
Astenopia , Humanos , Astenopia/etiologia , Consenso , China
3.
Appl Ergon ; 117: 104238, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38316071

RESUMO

The purpose of this paper is to establish an easy-to-use questionnaire for subjective evaluations of visually induced motion sickness (VIMS) and visual fatigue caused by stereoscopic 3D (s3D) images. We reviewed previously used questionnaires and extracted 51 important subjective evaluation items from them. We then recruited 251 participants to observe 3D images designed to easily induce sickness or visual fatigue, and we asked them to respond to the 51 items. As a result of exploratory factor analysis, four factors were extracted according to their factor loadings, and the number of items was reduced to 21. Further processing by confirmatory factor analysis led to the selection of 15 items. Comparing mean ratings for each factor before and after item reduction indicated that item reduction did not significantly affect the participant responses. Therefore, the 15-item Visually Induced Symptoms Questionnaire (VISQ), can be used to evaluate VIMS and s3D visual fatigue.


Assuntos
Astenopia , Enjoo devido ao Movimento , Humanos , Astenopia/etiologia , Imageamento Tridimensional , Enjoo devido ao Movimento/etiologia , Inquéritos e Questionários
4.
Work ; 77(1): 23-36, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37483045

RESUMO

BACKGROUND: Ever since the start of the coronavirus disease 2019 (COVID-19) pandemic, students have been spending an increasingly longer time staring at electrical devices to take online courses. OBJECTIVE: This study aimed to investigate the effect of the virtual class environment on eye and musculoskeletal problems in university students during the COVID-19 pandemic. METHODS: A total of 365 university students were enrolled in this study. They completed an online survey to examine the effects of online learning on eye and musculoskeletal health during the COVID-19 pandemic. The questionnaires consisted of four sections: demographic and general information, environmental and work factors, device-related factors, and visual display terminal syndrome (VDTS). RESULTS: Participants have been taking online classes of 14.5 hours per week during the COVID-19 pandemic. They reported the mean daily usage of digital devices of 4.8±2.2 hours before the pandemic but this increased to 8.1±2.9 during the pandemic. Eye fatigue and neck, shoulder, and back pain have also been reported. The mean VDTS score was significantly influenced by gender, obesity, daily exercise, regular breaks, wear of blue light-blocking glasses, daily hours of electronic device use, and illumination of room. CONCLUSION: The results of this study showed that university students taking online classes suffered more from VDTS, especially in eye fatigue and neck, lower back, and shoulder pain during COVID-19 pandemic than prior. This study suggests that it is necessary to take breaks in online classes and regularly provide appropriate eye exercise and physical activity to prevent VDTS.


Assuntos
Astenopia , COVID-19 , Humanos , Astenopia/epidemiologia , Astenopia/etiologia , COVID-19/epidemiologia , Pandemias , Universidades , Estudantes
5.
Exp Eye Res ; 239: 109744, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38072354

RESUMO

This study aimed to develop an enhanced environmental dry eye (EDE) model that accurately reproduces the etiology of prolonged visual fatigue and investigates the underlying pathological features. A total of 40 adult SPF-grade Wistar rats were randomly assigned to control (n = 20) and model (n = 20) groups. Rats in the control group were maintained under normal conditions, while rats in the model group were exposed to a controlled frontal airflow of 2-4 m/s from a fan for 7.5 h daily while placed on a suspended cylindrical wire mesh frame. Various assessments were performed at different time points during the 14-day experiment, including blink frequency, tear secretion (phenol red thread test), tear film breakup time (BUT), fluorescein staining (FL), corneal epithelial status (light microscopy), ultrastructure of corneal epithelial cells (electron microscopy), and expression levels of inflammatory cytokines (IL-1ß, TNF-α) in tears (enzyme-linked immunosorbent assay). Additionally, mRNA and protein expression levels of MMP-9, IL1ß, IL6, TNF-α, IFN-γ, and caspase-3 in corneal tissues were quantified (real-time quantitative PCR and Western blotting). Compared to the control group, the model group rats exhibited significant decreases in blink frequency (P < 0.001), tear secretion (Schirmer I test) values (P < 0.001), and tear film breakup time levels (P < 0.001). There was also a significant increase in fluorescein staining scores (P < 0.001) in the model group. Histological examination revealed distinct differences of the corneal epithelium between groups. The corneal epithelium of the model group appeared thicker, with disorganized cell arrangement in the superficial and basal layers, partial defects or detachment of superficial epithelial cells, and a rough, uneven surface. Scanning electron microscopy observations showed a rough corneal epithelial surface with numerous cracks and scattered vesicular-like structures in the model group. Furthermore, the model group rats exhibited a significant increase in expression of IL-1ß and TNF-α in tears (P < 0.001), and upregulated expression levels of MMP-9, TNF-α, IL-1ß, caspase-3, IL-6, and IFN-γ at both the mRNA and protein levels in corneal tissues (P < 0.001). In conclusion, the modified "wire-meshing cylindrical board" model effectively overcomes the limitations of the traditional "jogging board " dry eye model and successfully simulates the etiology of prolonged visual fatigue. This innovative EDE model demonstrates a high degree of relevance to dry eye conditions resulting from prolonged visual tasks, with a high success rate of model induction. Moreover, it proves to be a simple, practical, and easily replicable model, making it highly suitable for further studies on prolonged visual fatigue and facilitating its widespread adoption in research and clinical applications.


Assuntos
Astenopia , Síndromes do Olho Seco , Ratos , Animais , Metaloproteinase 9 da Matriz/genética , Metaloproteinase 9 da Matriz/metabolismo , Caspase 3/genética , Caspase 3/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , Astenopia/metabolismo , Ratos Wistar , Síndromes do Olho Seco/metabolismo , Lágrimas/metabolismo , Fluoresceína/metabolismo , Interleucina-1beta/metabolismo , RNA Mensageiro/metabolismo
6.
Indian J Ophthalmol ; 72(1): 98-104, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38131578

RESUMO

PURPOSE: This study aimed to determine the prevalence, risk factors, symptoms, and awareness of computer vision syndrome (CVS) among medical students during the coronavirus disease 2019 (COVID-19) pandemic. METHODS: A cross-sectional observational study was conducted among 283 undergraduate medical students at a tertiary healthcare center. An electronic survey was conducted to collect the data. Data were analyzed using Statistical Package for Social Sciences (SPSS version 23). The Chi-square test (Fisher's exact test when required) was used to study the significance of associations. A P value <0.05 was considered statistically significant. RESULTS: A high prevalence of CVS was observed in which 92% reported at least one symptom while using a digital device, the most frequent being eye strain (49%). Among extraocular complaints, joint pain in the wrist and fingers was most frequent. Significant association (P < 0.05) of CVS was found with increased duration of digital device usage, refractive error, use of glasses or contact lens, preexisting dry eye disease, and use of topical eye drops. 37% of the participants were aware of the 20-20-20 rule, while only 11% followed it. CONCLUSION: CVS is a common health concern among medical students. Hence, to increase the productivity of work, significant risk factors need to be addressed and awareness must be raised.


Assuntos
Astenopia , COVID-19 , Instrução por Computador , Estudantes de Medicina , Humanos , Pandemias , Estudos Transversais , COVID-19/epidemiologia
8.
BMC Ophthalmol ; 23(1): 508, 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38093208

RESUMO

BACKGROUND: Computer Vision Syndrome (CVS) is a complex of eye and visual problems that arise while using a computer or other Video Display Terminal (DVT). With the advent of the COVID-19 pandemic, the use of these DVTs has become indispensable in the lives of students and teachers. This study aims to identify the prevalence of CVS and associated factors in students and teachers at Lúrio University, in Nampula, during the pandemic period. METHODS: This is a cross-sectional study, carried out between November 2020 and March 2021. The validated CVS questionnaire (CVS-Q) and another semi-structured questionnaire on ergonomic risk factors were applied. Odds ratios (OR) and adjusted odds ratios (aOR) were calculated to measure the association between CVS and computer use conditions. RESULTS: The prevalence of CVS was 76.6%, and the female gender, age ≤ 20 years, levels I, II, III of course, lack of knowledge about ergonomics, use the computer to study, use more than 6 hours daily, absence of anti-reflex treatment, use of other devices and sitting in an inappropriate chair were risk factors for the occurrence of CVS, while being a teacher was a protective factor. CONCLUSION: The prevalence of CVS found in this study was high, due to several factors, especially not using ergonomic principles when using computers and other DVTs. There is a need to adopt intervention strategies focused on the most vulnerable groups such as women, age group ≤20 years and students, especially at the first year level, right after entering the University.


Assuntos
Astenopia , Pandemias , Humanos , Feminino , Adulto Jovem , Adulto , Estudos Transversais , Universidades , Moçambique , Astenopia/epidemiologia , Astenopia/etiologia , Síndrome , Inquéritos e Questionários , Computadores , Estudantes
9.
Nutr Res ; 120: 115-134, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37980835

RESUMO

The retina, an important tissue of the eye, is essential in visual transmission and sustaining adequate eyesight. However, oxidative stress and inflammatory reactions can harm retinal structure and function. Recent studies have demonstrated that exposure to light can induce oxidative stress and inflammatory reactions in retinal cells, thereby facilitating the progression of retinal damage-related diseases and asthenopia. Plant bioactive compounds such as anthocyanin, curcumin, resveratrol, lutein, zeaxanthin, epigallocatechin gallate, and quercetin are effective in alleviating retinal damage and asthenopia. Their strong oxidation resistance and unique chemical structure can prevent the retina from producing reactive oxygen species and regulating eye muscle relaxation, thus alleviating retinal damage and asthenopia. Additionally, the combination of these active ingredients produces a stronger antioxidant effect. Consequently, understanding the mechanism of retinal damage caused by light and the regulation mechanism of bioactive compounds can better protect the retina and reduce asthenopia.


Assuntos
Astenopia , Humanos , Disponibilidade Biológica , Retina , Antioxidantes/farmacologia , Antioxidantes/uso terapêutico , Estresse Oxidativo , Compostos Fitoquímicos/farmacologia , Compostos Fitoquímicos/uso terapêutico
10.
Int Ophthalmol ; 43(12): 4879-4885, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37923878

RESUMO

OBJECTIVE: To detect the presence of asthenopia after implantation of Implantable Collamer Lens (ICL). METHOD: Design: prospective observational case series. Patients with myopia and/or astigmatism who underwent ICL surgeries and completed 3-month follow-up were enrolled. Asthenopia scores, amplitude of accommodation (AA), positive/negative relative accommodation (PRA/NRA), accommodative facility (AF), the ratio of accommodative convergence and accommodation (AC/A), Schirmer test, noninvasive breakup time (NBUT), and HOA were examined before surgeries and at 1 week, 1 month and 3 months postoperatively then statistically analyzed. RESULTS: Symptoms of asthenopia were significantly decreased at 1 week after ICL surgeries than those before surgeries, but increased gradually as time went by, eventually recovered at 3 months postoperatively. AA, AF, AC/A decreased 1 week postoperatively, returned to the baseline at 1 month and were improved at 3 months after surgeries. NBUT at 1 week, 1 month and 3 months after surgeries were significantly decreased and was the lowest at 1 week postoperatively. PRA, NRA, Schiermer values and HOA had no significant change. Correlation analysis showed that the lower AF and NBUT after ICL surgeries, the more severe the asthenopia symptoms. CONCLUSION: The symptoms of asthenopia aggravated transiently after ICL implantation surgeries, but improved gradually with time. AF and NBUT were important factors affecting the changes of asthenopia.


Assuntos
Astenopia , Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular , Astenopia/diagnóstico , Astenopia/etiologia , Astenopia/cirurgia , Miopia/cirurgia , Acomodação Ocular
11.
Front Public Health ; 11: 1273886, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026296

RESUMO

Aim: This study aimed to assess the prevalence of Computer Vision Syndrome (CVS) among children and adolescents in Qatar during the period of remote learning and explore the associated factors and discuss some digital health remedies that might reduce the risk. Methods: We conducted an analytical cross-sectional study between June and August 2022 by collecting data via telephone interviews with parents of selected students utilizing the Computer Vision Syndrome Questionnaire (CVS-Q). Results: We completed 1,546 interviews. The mean age of the students was (11 ± 2), male: female ratio was almost 1:1. About one quarter (368, 23.8%) of parents reported a previous diagnosis of visual disturbances among their children with over 88% of them wearing eyeglasses or medical contact lenses. The prevalence of CVS in our sample was about 8% (95%CI: 6.8-9.6). Mother's employment, having positive history of visual disturbances, and excess screen time were found to be significant predictors of CVS. Conclusion: Health care providers in collaboration with teachers should provide parents with evidence-based strategies to prevent or minimize the digital eye strain among students. In the landscape of remote learning, the implementation of digital remedies emerges as a proactive approach to mitigate the risk of digital eye strain.


Assuntos
Astenopia , Criança , Adolescente , Humanos , Masculino , Feminino , Estudos Transversais , Astenopia/epidemiologia , Estudantes , Computadores , Síndrome
12.
Indian J Ophthalmol ; 71(12): 3707-3710, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37991308

RESUMO

PURPOSE: This study aimed to determine the effect of the blue light (BL) filter on the different tasks performed on a laptop on a daily basis. METHODS: Forty subjects were required to perform a 45-minute task on the laptop screen with or without the BL filter on two different days. In the first task, subjects were made to watch a video. In the second task, subjects were made to read a passage from the laptop for 3 minutes, and reading speed was calculated. In the third task, subjects were made to enter the data on the laptop. The time taken to fill in the data was recorded. After the completion of the task, questionnaires were administered. Pre- and post-task accommodative tests were performed. RESULTS: Forty emmetropes with a mean age of 21 ± 2 were recruited. In visual performance, the subjective response showed a significant difference in visual fatigue level with and without the filter. A statistically significant difference was seen in reading speed and data entry during task performance with and without the filter. Pre- and post-task accommodative parameters showed variable responses. CONCLUSION: This study showed that the use of a BL filter improves task performance, but subjectively, people experienced more visual fatigue while using the filter.


Assuntos
Astenopia , Análise e Desempenho de Tarefas , Humanos , Adulto Jovem , Adulto , Astenopia/diagnóstico , Astenopia/etiologia , Luz , Acomodação Ocular , Microcomputadores
13.
Sensors (Basel) ; 23(18)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37765755

RESUMO

Augmented reality (AR) has been shown to improve productivity in industry, but its adverse effects (e.g., headaches, eye strain, nausea, and mental workload) on users warrant further investigation. The objective of this study is to investigate the effects of different instruction methods (i.e., HoloLens AR-based and paper-based instructions) and task complexity (low and high-demanding tasks) on cognitive workloads and performance. Twenty-eight healthy males with a mean age of 32.12 (SD 2.45) years were recruited in this study and were randomly divided into two groups. The first group performed the experiment using AR-based instruction, and the second group used paper-based instruction. Performance was measured using total task time (TTT). The cognitive workload was measured using the power of electroencephalograph (EEG) features and the NASA task load index (NASA TLX). The results showed that using AR instructions resulted in a reduction in maintenance times and an increase in mental workload compared to paper instructions, particularly for the more demanding tasks. With AR instruction, 0.45% and 14.94% less time was spent on low- and high-demand tasks, respectively, as compared to paper instructions. According to the EEG features, employing AR to guide employees during highly demanding maintenance tasks increased information processing, which could be linked with an increased germane cognitive load. Increased germane cognitive load means participants can better facilitate long-term knowledge and skill acquisition. These results suggested that AR is superior and recommended for highly demanding maintenance tasks since it speeds up maintenance times and increases the possibility that information is stored in long-term memory and encrypted for recalls.


Assuntos
Astenopia , Realidade Aumentada , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Masculino , Humanos , Adulto , Cognição , Nível de Saúde
14.
Cochrane Database Syst Rev ; 8: CD013244, 2023 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-37593770

RESUMO

BACKGROUND: 'Blue-light filtering', or 'blue-light blocking', spectacle lenses filter ultraviolet radiation and varying portions of short-wavelength visible light from reaching the eye. Various blue-light filtering lenses are commercially available. Some claims exist that they can improve visual performance with digital device use, provide retinal protection, and promote sleep quality. We investigated clinical trial evidence for these suggested effects, and considered any potential adverse effects. OBJECTIVES: To assess the effects of blue-light filtering lenses compared with non-blue-light filtering lenses, for improving visual performance, providing macular protection, and improving sleep quality in adults. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL; containing the Cochrane Eyes and Vision Trials Register; 2022, Issue 3); Ovid MEDLINE; Ovid Embase; LILACS; the ISRCTN registry; ClinicalTrials.gov and WHO ICTRP, with no date or language restrictions. We last searched the electronic databases on 22 March 2022. SELECTION CRITERIA: We included randomised controlled trials (RCTs), involving adult participants, where blue-light filtering spectacle lenses were compared with non-blue-light filtering spectacle lenses. DATA COLLECTION AND ANALYSIS: Primary outcomes were the change in visual fatigue score and critical flicker-fusion frequency (CFF), as continuous outcomes, between baseline and one month of follow-up. Secondary outcomes included best-corrected visual acuity (BCVA), contrast sensitivity, discomfort glare, proportion of eyes with a pathological macular finding, colour discrimination, proportion of participants with reduced daytime alertness, serum melatonin levels, subjective sleep quality, and patient satisfaction with their visual performance. We evaluated findings related to ocular and systemic adverse effects. We followed standard Cochrane methods for data extraction and assessed risk of bias using the Cochrane Risk of Bias 1 (RoB 1) tool. We used GRADE to assess the certainty of the evidence for each outcome. MAIN RESULTS: We included 17 RCTs, with sample sizes ranging from five to 156 participants, and intervention follow-up periods from less than one day to five weeks. About half of included trials used a parallel-arm design; the rest adopted a cross-over design. A variety of participant characteristics was represented across the studies, ranging from healthy adults to individuals with mental health and sleep disorders. None of the studies had a low risk of bias in all seven Cochrane RoB 1 domains. We judged 65% of studies to have a high risk of bias due to outcome assessors not being masked (detection bias) and 59% to be at high risk of bias of performance bias as participants and personnel were not masked. Thirty-five per cent of studies were pre-registered on a trial registry. We did not perform meta-analyses for any of the outcome measures, due to lack of available quantitative data, heterogenous study populations, and differences in intervention follow-up periods. There may be no difference in subjective visual fatigue scores with blue-light filtering lenses compared to non-blue-light filtering lenses, at less than one week of follow-up (low-certainty evidence). One RCT reported no difference between intervention arms (mean difference (MD) 9.76 units (indicating worse symptoms), 95% confidence interval (CI) -33.95 to 53.47; 120 participants). Further, two studies (46 participants, combined) that measured visual fatigue scores reported no significant difference between intervention arms. There may be little to no difference in CFF with blue-light filtering lenses compared to non-blue-light filtering lenses, measured at less than one day of follow-up (low-certainty evidence). One study reported no significant difference between intervention arms (MD - 1.13 Hz lower (indicating poorer performance), 95% CI - 3.00 to 0.74; 120 participants). Another study reported a less negative change in CFF (indicating less visual fatigue) with high- compared to low-blue-light filtering and no blue-light filtering lenses. Compared to non-blue-light filtering lenses, there is probably little or no effect with blue-light filtering lenses on visual performance (BCVA) (MD 0.00 logMAR units, 95% CI -0.02 to 0.02; 1 study, 156 participants; moderate-certainty evidence), and unknown effects on daytime alertness (2 RCTs, 42 participants; very low-certainty evidence); uncertainty in these effects was due to lack of available data and the small number of studies reporting these outcomes. We do not know if blue-light filtering spectacle lenses are equivalent or superior to non-blue-light filtering spectacle lenses with respect to sleep quality (very low-certainty evidence). Inconsistent findings were evident across six RCTs (148 participants); three studies reported a significant improvement in sleep scores with blue-light filtering lenses compared to non-blue-light filtering lenses, and the other three studies reported no significant difference between intervention arms. We noted differences in the populations across studies and a lack of quantitative data. Device-related adverse effects were not consistently reported (9 RCTs, 333 participants; low-certainty evidence). Nine studies reported on adverse events related to study interventions; three studies described the occurrence of such events. Reported adverse events related to blue-light filtering lenses were infrequent, but included increased depressive symptoms, headache, discomfort wearing the glasses, and lower mood. Adverse events associated with non-blue-light filtering lenses were occasional hyperthymia, and discomfort wearing the spectacles. We were unable to determine whether blue-light filtering lenses affect contrast sensitivity, colour discrimination, discomfort glare, macular health, serum melatonin levels or overall patient visual satisfaction, compared to non-blue-light filtering lenses, as none of the studies evaluated these outcomes. AUTHORS' CONCLUSIONS: This systematic review found that blue-light filtering spectacle lenses may not attenuate symptoms of eye strain with computer use, over a short-term follow-up period, compared to non-blue-light filtering lenses. Further, this review found no clinically meaningful difference in changes to CFF with blue-light filtering lenses compared to non-blue-light filtering lenses. Based on the current best available evidence, there is probably little or no effect of blue-light filtering lenses on BCVA compared with non-blue-light filtering lenses. Potential effects on sleep quality were also indeterminate, with included trials reporting mixed outcomes among heterogeneous study populations. There was no evidence from RCT publications relating to the outcomes of contrast sensitivity, colour discrimination, discomfort glare, macular health, serum melatonin levels, or overall patient visual satisfaction. Future high-quality randomised trials are required to define more clearly the effects of blue-light filtering lenses on visual performance, macular health and sleep, in adult populations.


Assuntos
Astenopia , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Melatonina , Adulto , Humanos , Óculos , Sono , Luz
15.
Indian J Ophthalmol ; 71(6): 2592-2594, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37322686

RESUMO

COVID-19 infection has been linked to various ocular complications and complaints, but not to refractive errors. In this case report, we present ethnically diverse patients who reported asthenopic symptoms shortly after recovering from COVID-19 infection. The hyperopic shift in the refractive error, post-COVID could indicate the ciliary body muscle's inability to sustain accommodation, resulting in asthenopia. Hence, refractive errors should also be considered as a post-COVID complication, even if the magnitude is small, especially when patients have a headache and other asthenopic symptoms. Performing dynamic retinoscopy and cycloplegic refraction will also aid in the better management of these patients.


Assuntos
Astenopia , COVID-19 , Hiperopia , Erros de Refração , Humanos , Astenopia/diagnóstico , Astenopia/etiologia , COVID-19/complicações , Erros de Refração/diagnóstico , Erros de Refração/etiologia , Acomodação Ocular
17.
Nutrients ; 15(11)2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37299596

RESUMO

When the eyes are exposed to the environment, they are easily affected by strong light stimulation and harmful substances. At the same time, prolonged use of the eyes or incorrect eye habits can cause visual fatigue, which mainly manifests as eye dryness, soreness, blurred vision, and various discomforts. The main reason for this is a decline in the function of the eye, especially the cornea and retina on the surface of the eye, which have the greatest impact on the normal function of the eye. Research has found that supplementation with appropriate foods or nutrients can effectively strengthen the eye against external and internal stimuli, thereby alleviating or avoiding visual fatigue. Among these, supplementation with polyunsaturated fatty acids has been found to be effective at protecting eye health and relieving visual fatigue. This article summarizes the sources of polyunsaturated fatty acids (including the main dietary sources and internal synthesis), the mechanisms of digestion and absorption of polyunsaturated fatty acids in the body and the safety of polyunsaturated fatty acid applications. It also reviews the mechanism of action of polyunsaturated fatty acids in aiding the relief of visual fatigue based on the mechanism of impaired function or structure of the ocular surface and fundus in the hope of providing some reference and insight into the development and application of polyunsaturated fatty acids in functional foods for the relief of visual fatigue.


Assuntos
Astenopia , Ácidos Graxos Ômega-3 , Humanos , Ácidos Graxos Insaturados , Alimento Funcional , Digestão , Ácidos Graxos
18.
Zhonghua Yan Ke Za Zhi ; 59(6): 452-459, 2023 Jun 11.
Artigo em Chinês | MEDLINE | ID: mdl-37264575

RESUMO

Objective: To design a visual fatigue questionnaire that can be used for population surveys. Methods: This was a cross-sectional study that involved three stages of subjects' recruitment. In the first stage, by convenience sampling, 150 individuals who complained of visual fatigue were selected at public places in Wenzhou City in May 2016. The 19-Item Asthenopia Survey Questionnaire (ASQ-19) was used to conduct the survey, and the questionnaire was adjusted. In the second stage, 200 outpatient participants were recruited from Wenzhou Medical University Affiliated Eye and Optometry Hospital from June 2016 to May 2017 and were divided into a visual fatigue group and a control group based on clinical diagnosis. The adjusted visual fatigue questionnaire was used for validation. In the third stage, 64 outpatient participants who met the inclusion criteria were continuously recruited from the Wenzhou Medical University Affiliated Eye and Optometry Hospital in July 2022. They were tested using the adjusted visual fatigue questionnaire and retested one week later. During the questionnaire adjustment stage, factor analysis and feedback were used to adjust the scoring method and items of the ASQ-19 questionnaire. The adjusted questionnaire was then analyzed for reliability, validity, accuracy, and subject acceptance during the validation and retest stages. Results: A total of 403 participants were included, and 456 questionnaires were distributed. Eventually, 432 valid questionnaires were collected from 379 participants, resulting in a valid response rate of 94.7%. During the questionnaire adjustment phase, there were 140 valid questionnaires from 140 participants consisting of 56 males and 84 females with an average age of (35.2±12.4) years. In the questionnaire validation phase, there were 186 valid questionnaires from 186 participants. Sixty-two participants had visual fatigue and 124 were controls. During the questionnaire retesting phase, 53 participants yielded 106 valid questionnaires. The group consisted of 20 males and 33 females with an average age of (22.8±4.9) years. After factor analysis, the symptom severity graded as none, mild, moderate, severe, and very severe was scored as 0, 1, 2, 3, and 4 points, respectively. The total score was 44, and the final questionnaire consisted of 11 items (numbered 1, 2, 3, 5, 6, 8, 10, 15, 17, 18, and 19). The 11-Item Asthenopia Survey Questionnaire (ASQ-11) had a Cronbach's α coefficient of 0.89, a split-half reliability of 0.82, and a test-retest Pearson correlation coefficient of 0.90 (P<0.001). The structural validity was 51.26%, and the discriminative validity was a t-value of 9.19 (P<0.001). On average, it took (2.82±0.43) minutes for participants to complete the questionnaire. The receiver operating characteristic curve had a cutoff value of 8.5, with a sensitivity of 74.19% and a specificity of 80.65%. Conclusion: The ASQ-11, with fewer items and a shorter completion time, is easy for participants to use and is suitable for screening or self-assessment of visual fatigue in the general population. Additionally, it is convenient for clinical and epidemiological studies related to visual fatigue.


Assuntos
Astenopia , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Adolescente , Reprodutibilidade dos Testes , Estudos Transversais , Inquéritos e Questionários , Curva ROC
19.
Opt Express ; 31(6): 10420-10433, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-37157589

RESUMO

People spend about 5-8 hours per day on phones, causing circadian disruption and eye fatigue, thus raising a great need for comfort and health. Most phones have eye protection modes, claiming a potential eye protection effect. To examine the effectiveness, we investigated the color quality, namely gamut area and just noticeable color difference (JNCD), and circadian effect, namely equivalent melanopic lux (EML) and melanopic daylight efficacy ratio (MDER), characteristics of two smartphones: iPhone 13 and HUAWEI P30, in normal and eye protection mode. The results show that the circadian effect is inversely proportional to color quality when the iPhone 13 and HUAWEI P30 changed from normal to eye protection mode. The gamut area changed from 102.51% to 82.5% sRGB and 100.36% to 84.55% sRGB, respectively. The EML and MDER decreased by 13 and 15, and, 0.50 and 0.38, respectively, affected by the eye protection mode and screen luminance. The EML and JNCD results in different modes show that the eye protection mode benefits the nighttime circadian effect at the cost of the image quality. This study provides a way to precisely assess the image quality and circadian effect of displays and elucidates the tradeoff relationship between them.


Assuntos
Astenopia , Smartphone , Humanos , Ritmo Circadiano , Astenopia/prevenção & controle
20.
J Robot Surg ; 17(5): 1873-1878, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37204648

RESUMO

Stereopsis may be an advantage of robotic surgery. Perceived robotic ergonomic advantages in visualisation include better exposure, three-dimensional vision, surgeon camera control, and line of sight screen location. Other ergonomic factors relating to visualisation include stereo-acuity, vergence-accommodation mismatch, visual-perception mismatch, visual-vestibular mismatch, visuospatial ability, visual fatigue, and visual feedback to compensate for lack of haptic feedback. Visual fatigue symptoms may be related to dry eye or accommodative/binocular vision stress. Digital eye strain can be measured by questionnaires and objective tests. Management options include treatment of dry eye, correction of refractive error, and management of accommodation and vergence anomalies. Experienced robotic surgeons can use visual cues like tissue deformation and surgical tool information as surrogates for haptic feedback.


Assuntos
Astenopia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Astenopia/etiologia , Astenopia/prevenção & controle , Percepção de Profundidade , Acomodação Ocular , Ergonomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...