Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.401
Filtrar
1.
Artigo em Chinês | MEDLINE | ID: mdl-38296241

RESUMO

In September 8th, 2021, a male patient (aged 18 years) with severe destructive injuries of high-voltage electric burns in the head, face, and neck was admitted to General Hospital of Taiyuan Iron Steel (Group) Co., Ltd. Based on the economic theory of flaps, the flap donor site and transplantation method were optimized and evaluated before surgery, and then debridement of head, face, and neck wounds+removal of necrotic skull+free transplantation of super large latissimus dorsi myocutaneous flap+thin intermediate thickness skin graft transplantation from the left thigh was performed. The extra large flap donor site wound was sutured directly. This surgery reduced the adverse consequences of the flap donor site on the premise of ensure of repair effect. After operation, the patient's condition was stable, the flap and skin graft survived well, the repair effect of wound was well, the scar in the flap donor area was relatively mild, and the upper limb had no dysfunction.


Assuntos
Queimaduras por Corrente Elétrica , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Humanos , Masculino , Queimaduras por Corrente Elétrica/cirurgia , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Retalhos Cirúrgicos/cirurgia , Cicatrização , Adolescente
2.
Microsurgery ; 44(1): e31057, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37199482

RESUMO

Volar finger contractures can be challenging for plastic surgeons. The dorsal metacarpal artery perforator (DMCAP) flap is frequently used to cover bones, tendons, and neurovascular structures in the dorsum of the hand after trauma and burns as an alternative to grafts and free flaps. We aimed to report volar finger defect reconstruction with expanded DMCAP flap. A 9-year-old male patient applied to our clinic with the complaint of inability to open the second finger of the left hand after an electrical burn that caused proximal and distal interphalangeal joints flexion contractures. Reconstruction was planned for the patient with a two-session expanded first DMCAP flap. A 16 mL 5 × 3 cm tissue expander was placed in the prepared area from the vertical incision in the first session. The tissue expander was inflated with 4 mL of isotonic solution. The DMCA area was enlarged 6 weeks later by giving 22 mL of isotonic solution. After the pedicle dissection, the 9 × 3 cm DMCAP flap was elevated by dissection over the paratenon. With 180° of rotation, the left-hand second finger was adapted to the 6 × 2 cm defect area on the volar face. The flap donor site was closed primarily. The operation was terminated by placing the hand on a protective splint. There were no complications in the flap in the postoperative 6 months. The patient was referred to the physical therapy and rehabilitation department. As a result, an expanded DMCAP flap may cover volar tissue defects up to the distal phalanx. This report may present the first case in which volar finger contracture reconstruction was performed with an expanded first DMCAP flap after an electrical burn in a pediatric patient.


Assuntos
Queimaduras por Corrente Elétrica , Contratura , Traumatismos dos Dedos , Ossos Metacarpais , Retalho Perfurante , Lesões dos Tecidos Moles , Masculino , Humanos , Criança , Retalho Perfurante/irrigação sanguínea , Queimaduras por Corrente Elétrica/cirurgia , Ossos Metacarpais/cirurgia , Resultado do Tratamento , Dedos/cirurgia , Contratura/etiologia , Contratura/cirurgia , Artérias/cirurgia , Soluções Isotônicas , Traumatismos dos Dedos/cirurgia , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia
3.
J Burn Care Res ; 45(2): 478-486, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-37962554

RESUMO

Burn prevention programs can effectively reduce morbidity and mortality rates. In this article, we present the findings of our investigation of the knowledge, attitudes, and practices of the Saudi Arabian population regarding electrical burns. Our study was a cross-sectional online survey that used a five-part questionnaire to assess the participant's demographic information, knowledge of electrical burns, attitudes toward electrical injuries, and practices related to electrical burns and their prevention. Overall, 2314 individuals responded to the survey (males: 41.2%; females: 58.8%). A total of 839 participants (36%) had a personal or family history of electrical burns. Approximately ≥90% of the responses to questions on electrical burn-related knowledge were correct; relatively less responses to questions on the extent of tissue damage from electrical burns and arcs were correct (74% and 29%, respectively). Only 54% of the respondents knew that applying first aid to the burn-affected areas at home could lead to a better outcome; 27% and 19% did not know the correct answer and thought that this would not lead to a better outcome, respectively. The most common source of information was school or college (38.9%), followed by social media (20.8%) and internet websites (16.3%). Enhancing community awareness and practices related to electrical burns is a cost-effective and straightforward strategy to prevent the morbidity and mortality associated with electrical injuries.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Masculino , Feminino , Humanos , Queimaduras por Corrente Elétrica/terapia , Queimaduras/terapia , Conhecimentos, Atitudes e Prática em Saúde , Estudos Transversais , Arábia Saudita
4.
J Burn Care Res ; 45(2): 493-498, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-37982657

RESUMO

Electrical burns pose unique challenges in reconstructive surgery due to the extensive tissue damage they cause. The thumb is particularly susceptible to electrical burns, leading to severe functional impairment. This case series introduces the use of the temporal fascia free flap for thumb coverage in patients with electrical burn injuries. The study aims to assess the functional outcomes of this approach using the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire. Six male patients underwent thumb reconstruction using temporal fascia free flaps following electrical burn injuries. The extent of the injury was assessed, and necrotic tissue was debrided. Functional outcomes were evaluated using the DASH questionnaire 6 months postoperation. All procedures were conducted in accordance with ethical guidelines, and informed consent was obtained from all patients. All patients achieved successful transplants using temporal fascia free flaps. The average DASH score at the 6-month follow-up indicated satisfactory functional recovery. Patients reported improvements in thumb mobility and functionality, and the cosmetic appearance of the thumb was acceptable. The appearance of the scar in the donor area was well-received. The temporal fascia free flap proved to be an effective method for thumb reconstruction following electrical burn injuries. Its thin and flexible nature allows for optimal contouring and improved range of motion. Although one case of partial flap loss was observed, overall functional and aesthetic outcomes were satisfactory. Further research with larger sample sizes is warranted to optimize surgical techniques and postoperative care for better outcomes.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Retalhos de Tecido Biológico , Humanos , Masculino , Queimaduras por Corrente Elétrica/cirurgia , Polegar/cirurgia , Ombro , Queimaduras/cirurgia , Resultado do Tratamento
5.
J Burn Care Res ; 45(2): 525-527, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38006581

RESUMO

Advancements in technology allow for the utilization of low-voltage battery-powered devices for patients admitted to the hospital. There have been rare cases of burns due to leakage of the internal contents from low-voltage batteries, but to date, there have been no reports of electrical burns caused by low-voltage batteries. We present the case of an 89-year-old female who presented to the general surgery service with a suspected electrical burn from laying on a 9-volt battery. The patient underwent operative debridement with no evidence of a deeper injury. The patient continues to follow up with an outpatient wound clinic and is healing well. This case highlights the importance of teaching and raising awareness of all small devices that may become entangled or lost in patients' linens, such as 9-volt telemetry batteries, to prevent harm.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Feminino , Humanos , Idoso de 80 Anos ou mais , Queimaduras/cirurgia , Queimaduras/etiologia , Queimaduras por Corrente Elétrica/cirurgia , Queimaduras por Corrente Elétrica/complicações , Cicatrização , Hospitalização , Fontes de Energia Elétrica
6.
J Burn Care Res ; 45(2): 512-519, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38141257

RESUMO

High-voltage electrical injury usually causes severe tissue damage and serious secondary complications. We report a case of treatment of severe high-voltage electrical injury. A series of personalized and effective treatment plans were created through repeated discussions, we successfully handled a series of acute and critical conditions, including severe limb damage, a very large area of full-thickness abdominal wall defect, abdominal viscera (stomach and liver) necrosis, abdominal infection, renal insufficiency, myocardial damage, and malignant arrhythmia (atrial fibrillation). Finally, the wounds were all closed, the functions of the abdominal organs were restored, and the course of the disease was successfully transitioned into the rehabilitation stage. It took a lot of twists and turns but ultimately saved the patient's life. The successful treatment of this patient provides an important reference for similar patients with serious electrical injury in the future.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Procedimentos de Cirurgia Plástica , Humanos , Queimaduras por Corrente Elétrica/terapia , Queimaduras por Corrente Elétrica/cirurgia , Queimaduras/complicações , Transplante de Pele , Eletricidade
7.
Zhonghua Shao Shang Yu Chuang Mian Xiu Fu Za Zhi ; 39(12): 1180-1184, 2023 Dec 20.
Artigo em Chinês | MEDLINE | ID: mdl-38129306

RESUMO

Objective: To explore the effects of artificial dermis combined with autologous skin in repairing the wounds with exposed bone and/or tendon in fingers of children after electric burns. Methods: A retrospective observational study was conducted. From January 2017 to December 2022, 14 children with bone and/or tendon exposed wounds in fingers after electric burns who met the inclusion criteria were admitted to Zhengzhou First People's Hospital, including 9 males and 5 females, aged 2 to 11 years. A total of 38 fingers were affected, with 1 wound per finger. After debridement, artificial dermal coverage combined with vacuum sealing drainage was performed in all the wounds in the first stage, with wound area of 2.0 cm×1.0 cm-4.5 cm×2.5 cm after debridement. The second stage surgery was performed to close the wound with autologous thin intermediate thickness skin graft. Then the children were told to perform functional rehabilitation exercise as early as possible. The survival of autologous skin graft was observed at the 7th day after the second stage surgery. The wound healing time was recorded. After 12 months of follow-up, the Vancouver scar scale was used to evaluate the scar hyperplasia at the skin grafting site of the affected finger; the total action mobility (TAM) of the affected finger joint was measured for evaluating the functional recovery of the affected finger; a self-made efficacy satisfaction rating table was used to investigate the parents' satisfaction with the curative effect of the children. Results: At the 7th day after the second stage surgery, all the children had good survival of autologous skin grafts. The wound healing time was (24.1±2.7) d. After 12 months of follow-up, the scar score at the skin grafting site of the affected finger was 5.2±2.4; the TAM of the affected finger joint was (177±40)°; the functional assessment was good in 12 fingers, medium in 23 fingers, and poor in 3 fingers; the parents' satisfaction with the curative effect of the children in the survey was very satisfied in 10 cases, satisfied in 3 cases, and dissatisfied in 1 case. Conclusions: The combination of artificial dermis and autologous thin intermediate thickness skin graft is an alternative surgical method that can effectively repair the bone and/or tendon exposed wounds in fingers of children after electric burns. After wound healing, the scars are slight, the finger function is well recovered, and the parents of the children are highly satisfied with the curative effect of the children, which is worthy of clinical promotion.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Lesões dos Tecidos Moles , Criança , Feminino , Humanos , Masculino , Queimaduras/cirurgia , Queimaduras por Corrente Elétrica/cirurgia , Cicatriz/cirurgia , Derme/cirurgia , Transplante de Pele/métodos , Lesões dos Tecidos Moles/cirurgia , Tendões/cirurgia , Resultado do Tratamento , Cicatrização , Estudos Retrospectivos
8.
Artigo em Chinês | MEDLINE | ID: mdl-37899559

RESUMO

Objective: To explore the selection strategy of pedicled axial flaps for repairing high-voltage electric burn wounds in foot and ankle. Methods: The retrospective observational research method was used. From January 2017 to December 2022, 16 patients with skin and soft tissue defects in foot and ankle after high-voltage electric burns were treated in General Hospital of Eastern Theater Command, including 11 cases of unilateral defect and 5 cases of bilateral defect. All patients were male, aged from 25 to 75 years. After thorough debridement, the area of the defect to be repaired with the flap was 5.0 cm×4.0 cm to 12.0 cm×8.0 cm. Before operation, the color Doppler ultrasound, computed tomography angiography, or digital subtraction angiography was used to fully evaluate the degree of vascular injury in the affected limb and to identify the distribution and traffic anastomosis of vascular network. Pedicled axial flaps with reliable blood supply were used to repair the wounds as soon as possible, and the area of flaps ranged from 3.0 cm×2.0 cm to 13.0 cm×8.0 cm. The wound in the donor area of flaps was repaired with split-thickness skin graft from head or medium-thickness skin graft from thigh. The flap repair of wounds in various areas of the ankle and foot was recorded. The postoperative survivals of the flaps and skin grafts were observed after surgery. The postoperative appearance of flaps and walking function of patients were followed up. At the last follow-up, the foot and ankle function was evaluated and rated using the American Association of Foot and Ankle Surgeons Ankle Posterior Foot Scoring System. Results: Two wounds in toe area were repaired with reverse dorsal pedis flaps, 3 wounds in medial ankle area and 2 wounds in heel area were repaired with medial plantar flaps, 2 wounds in anterior plantar area combined with toe area were repaired with reverse medial plantar flaps, 2 wounds in anterior plantar area combined with toe area and 5 wounds in anterior plantar area were repaired with reverse medial pedis flaps, 1 wound in toe area was combined with proper plantar digital artery flap, 1 dorsal pedis wound and 1 lateral malleolus wound were repaired with lateral supramalleolar perforator flaps, and 1 lateral malleolus wound and 1 dorsal pedis wound were repaired with sural neurovascular flap. One flap had venous reflux disorder after surgery and survived after treatment, while the other flaps and skin grafts survived completely after surgery. During the follow-up of 6 to 24 months after operation, the appearance of the flaps was good, and the walking function of patients was normal. At the last follow-up, the functional score of foot and ankle was 76 to 95, which was evaluated as excellent in 11 cases and good in 5 cases. Conclusions: According to the condition of high-voltage electric burn in foot and ankle, early and thorough debridement, preoperative imaging examination to evaluate blood vessels of the affected limb, and selection of pedicled axial flap with reliable blood supply are good methods for wound repair and related functional reconstruction of high-voltage electric burn in foot and ankle.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Feminino , Humanos , Masculino , Tornozelo/cirurgia , Queimaduras/cirurgia , Queimaduras por Corrente Elétrica/cirurgia , Estudos Retrospectivos , Lesões dos Tecidos Moles/cirurgia , Cicatrização , Adulto , Pessoa de Meia-Idade , Idoso
9.
Artigo em Chinês | MEDLINE | ID: mdl-37899561

RESUMO

Objective: To explore the effects of low position lateral supramalleolar flap carrying periosteum and proximal leg propeller flap in relay repair of electric burn wounds of forefoot. Methods: A retrospective observational study was conducted. From January 2019 to January 2022, 12 patients with electric burn wounds of forefoot meeting the inclusion criteria were admitted to the Sixth Hospital of Shanxi Medical University, including 10 males and 2 females, aged 23-65 years. After debridement, the wound with an area of 6.0 cm×3.0 cm to 15.0 cm×7.0 cm was repaired with the lateral supramalleolar flap carrying part of the periosteum of the distal tibia and fibula with the rotation point moved down to the front of the ankle joint. The area of the cutted flap was 6.5 cm×3.5 cm-15.5 cm×7.5 cm. At the same stage, the donor site wound of lateral supramalleolar flap was repaired with peroneal artery or superficial peroneal artery perforator propeller flap in relay, with the relay flap area of 3.0 cm×1.5 cm-15.0 cm×4.0 cm. After operation, the survival of the lateral supramalleolar flap and relay flap, and the wound healing of the relay flap donor site were observed. During follow-up, the shapes of the lateral supramalleolar flap and its donor site were observed. Results: After operation, one patient developed secondary blisters in the superficial skin distal to the lateral supramalleolar flap, which healed after dressing change, and the lateral supramalleolar flap and relay flaps survived well in the other patients; the donor site wound of the relay flap healed well. During follow-up of 12-18 months, the lateral supramalleolar flaps were in good shape and not bloated, with only linear scar left in the donor site of the flap. Conclusions: The low position lateral supramalleolar flap carrying periosteum can repair electric burn wounds of forefoot with advantages including reliable blood supply, low rotation point, and better repair effects. The use of relay flap to repair the donor site of lateral supramalleolar flap can reduce the damage to the appearance and function of the donor site.


Assuntos
Queimaduras por Corrente Elétrica , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Feminino , Humanos , Masculino , Queimaduras por Corrente Elétrica/cirurgia , Perna (Membro)/cirurgia , Periósteo/cirurgia , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Resultado do Tratamento , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso
10.
Artigo em Chinês | MEDLINE | ID: mdl-37899564

RESUMO

Objective: To analyze the literature on electric burns published at home and abroad, and to explore the research hotspots and frontiers of electric burns. Methods: The bibliometric method was used. The Chinese and English literature related to electric burns published in China National Knowledge Infrastructure, Wanfang database, VIP database and the core collection of Web of Science database from January 1, 2013 to December 31, 2022 were searched respectively, and the CiteSpace 6.2.R2 software was used for analysis. The number of papers, authors, countries, and institutions of Chinese and English literature were counted respectively, and the co-occurrence analysis of keywords and mutation analysis and cluster analysis on the basis of the co-occurrence analysis were conducted, besides, the clustering time line figure was obtained after the keywords were sorted by time to explore the current research status and the evolution process of hotspots in the field of electric burns. Results: A total of 398 English papers were retrieved from the core collection of Web of Science database, and a total of 523 Chinese papers were retrieved from China National Knowledge Infrastructure, Wanfang database, and VIP database after duplicate check. From 2013 to 2022, the number of English literature published in the field of electric burns showed a steadily upward trend, and the number of published Chinese literature showed a downward trend and tended to be stable. In Chinese literature, a total of 302 authors as the first author published papers related to electric burns, with 17 core authors published ≥3 papers; in English literature, a total of 320 authors as the first author published papers related to electric burns. Researches on electric burns were carried out in 65 countries, with United States having the most cooperation with other countries and the largest number of papers published. A total of 512 institutions at home and abroad published papers related to electric burns, and the institutions with the largest number of Chinese and English papers were Shanghai Electric Power Hospital in China (n=14) and Hallym University in Korea (n=11), respectively. A total of 1 176 Chinese keywords and 1 068 English keywords were included for co-occurrence analysis after excluding keywords related to the searching words. The top three keywords in frequency in Chinese literature were surgical flap, wound repair, and nursing, and the top three keywords in frequency in English literature were management, epidemiology, and children. Ten clusters were obtained by keyword analysis in Chinese literature, and the largest cluster was wound healing, followed by clinical effects and surgical flaps. Seven clusters were obtained by keyword analysis in English literature, and the largest cluster was reconstructive surgical procedures, followed by chronic pain and shock. The persistent clusters in Chinese literature were wound healing and clinical outcomes, etc., and the prominent nodes in the recent two years were surgical timing, limb electric burns, and hypertrophic scars; the persistent clusters in English literature were reconstructive surgical procedures and chronic pain, etc., and the prominent nodes in the recent two years were predictors and burn management, etc. In Chinese literature, the keyword with the longest duration of mutation (2017-2021) was wrist electric burns, and the keyword with the highest intensity of mutation was flap repair; in English literature, the keyword with the longest duration of the mutation (2019-2022) was voltage, and the keyword with the highest intensity of mutation was prevention. Conclusions: There are similarities and differences in the research directions and hotspots of electric burns at home and abroad. Surgical flap repair is a common research hotspot at home and abroad. At present, domestic research focuses on wound healing, wrist electric burns, and other aspects, while international research focuses on treatment management, epidemiology, reconstruction, and other aspects.


Assuntos
Queimaduras por Corrente Elétrica , Dor Crônica , Criança , Humanos , Estados Unidos , China/epidemiologia , Retalhos Cirúrgicos , Bibliometria
11.
Artigo em Chinês | MEDLINE | ID: mdl-37805715

RESUMO

The treatment of burn wounds of special causes and sites is a very challenging clinical work. In this paper, we briefly discussed the incidence rates of chemical burns, electric burns, facial burns, hand burns, and perineal burns, as well as the complexity and severity of pathological injury of the corresponding wound tissue. In addition, we briefly discussed the main principles and methods of clinical treatment, as well as the difficult problems to be solved. It is hoped to attract attention and provide reference for further improving the overall treatment ability of burns.


Assuntos
Queimaduras Químicas , Queimaduras por Corrente Elétrica , Traumatismos Faciais , Traumatismos da Mão , Traumatismos do Punho , Humanos , Queimaduras por Corrente Elétrica/terapia
12.
Artigo em Chinês | MEDLINE | ID: mdl-37805718

RESUMO

Objective: To explore the effects of free gracilis muscle flap combined with sural nerve transfer for reconstruction of digital flexion and sensory function of hand in patient with severe wrist electric burn. Methods: A retrospective observational study was conducted. From January 2017 to December 2020, 4 patients with wrist high-voltage electric burn admitted to the Department of Burns of the First People's Hospital of Zhengzhou and 4 patients with wrist high-voltage electric burn admitted to the Department of Hand Surgery of Beijing Jishuitan Hospital met the inclusion criteria, including 6 males and 2 females, aged 12 to 52 years. They were all classified as type Ⅱ wrist high-voltage electric burns with median nerve defect. In the first stage, the wounds were repaired with free anterolateral thigh femoral myocutaneous flap. In the second stage, the free gracilis muscle flap combined with sural nerve transplantation was used to reconstruct the digital flexion and sensory function of the affected hand in 3 to 6 months after wound healing. The cut lengths of muscle flap and nerve were 32 to 38 and 28 to 36 cm, respectively. The muscle flap donor area and nerve donor area were both closed and sutured. The survival condition of gracilis muscle flap and sural nerve, the wound healing time of recipient area on forearm, the healing time of suture in muscle flap donor area and nerve donor area were observed and recorded after operation, and the recovery of donor and recipient areas was followed up. In 2 years after operation, the muscle strength of thumb and digital flexion and finger sensory function after the hand function reconstruction were evaluated with the evaluation criteria of the hand tendon and nerve repair in the trial standard for the evaluation of functions of upper limbs of Hand Surgery Society of Chinese Medical Association. Results: All the gracilis muscle flap and sural nerve survived successfully after operation. The wound healing time of recipient area on forearm was 10 to 14 days after operation, and the healing time of suture in muscle flap donor area and nerve donor area was 12 to 15 days after operation. The donor and recipient areas recovered well. In the follow-up of 2 years after operation, the muscle strength of thumb and digital flexion was evaluated as follows: 4 cases of grade 5, 3 cases of grade 4, and 1 case of grade 2; the finger sensory function was evaluated as follows: 4 cases of grade S3+, 2 cases of grade S3, and 2 cases of grade S2. Conclusions: For patients with hand dysfunction caused by severe wrist electric burn, free gracilis muscle flap combined with sural nerve transplantation can be used to reconstruct the digital flexion and sensory function of the affected hand. It is a good repair method, which does not cause great damage to thigh muscle flap donor area or calf nerve donor area.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Músculo Grácil , Traumatismos da Mão , Transferência de Nervo , Retalho Perfurante , Lesões dos Tecidos Moles , Traumatismos do Punho , Feminino , Humanos , Masculino , Queimaduras/cirurgia , Queimaduras por Corrente Elétrica/cirurgia , Músculo Grácil/cirurgia , Mãos/cirurgia , Traumatismos da Mão/cirurgia , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Nervo Sural/cirurgia , Resultado do Tratamento , Extremidade Superior/cirurgia , Cicatrização , Punho/cirurgia , Traumatismos do Punho/cirurgia , Estudos Retrospectivos
13.
Artigo em Chinês | MEDLINE | ID: mdl-37805767

RESUMO

Objective: To investigate the clinical effect of the giant deep inferior epigastric artery paraumbilical perforator flap in repairing the circular high-voltage electric burn wounds on the wrist. Methods: A retrospective observational study method was used. From September 2016 to October 2021, thirteen male patients (aged 20-43 years) with annular high voltage (10-100 kV) electrical burns on the wrist were admitted to the Beijing Jishuitan Hospital. At the early stage after injury, the patient's wrist was subjected to incision, tension reduction and debridement, with the wound area after debridement being 27 cm×16 cm-32 cm×19 cm; in 12 patients with vascular injury, the radial or ulnar artery was reconstructed by great saphenous vein transplantation, with the length of 15-25 cm; the wrist wound was repaired by free transplantation of the deep inferior epigastric artery paraumbilical perforator flap (if the wound was giant, the lower abdominal flap carrying other perforators was used), with the area of 30 cm×19 cm-35 cm×20 cm. The donor site was repaired by direct suture+skin grafting or relay flap transplantation. After surgery, the survival of flap in recipient area, as well as survival of the skin or flap in donor site were observed. During follow-up, the appearances of the flap in recipient area and the recovery of hand function, as well as the healing of donor site, occurrence of abdominal wall hernia, and scar in skin graft area were observed. Results: After surgery, all the 13 patients' paraumbilical perforator flaps survived. Among them, 3 patients had subcutaneous fat necrosis at the distal end of the wrist flap, and the wound had mild infection, which healed after re-expansion and dressing change. All the skin grafts in the donor site of 10 patients survived, and the flaps in the donor site of 3 patients survived well. The patients were followed up for 6 months to 3 years. The flaps in recipient area were in good shape, 8 cases had partial recovery of hand function, and 5 cases had loss of finger flexion function; the donor site of abdominal flap healed well with no abdominal hernia occurred, and the skin graft site had no obvious scar hyperplasia and was soft in texture. Conclusions: Early vascular reconstruction after injury, together with free transplantation of the giant deep inferior epigastric artery paraumbilical perforator flap are effective in repairing circular high-voltage electrical burn wounds on the wrist.


Assuntos
Queimaduras por Corrente Elétrica , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Humanos , Masculino , Queimaduras por Corrente Elétrica/cirurgia , Cicatriz/cirurgia , Artérias Epigástricas/cirurgia , Estudos Retrospectivos , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Resultado do Tratamento , Punho/cirurgia , Traumatismos do Punho/etiologia , Traumatismos do Punho/cirurgia , Adulto Jovem , Adulto
14.
Artigo em Chinês | MEDLINE | ID: mdl-37805780

RESUMO

Electric burn is a kind of three-dimensional destructive damage. It is necessary to attach great importance to the functional reconstruction and rehabilitation of patients with destructive electric burns. Wound repair and limb salvage are not the end of the treatment of destructive electric burns, but functional rehabilitation and reintegration into society of patients are the goals of treatment. This paper systematically discusses the early wound repair, late functional reconstruction and rehabilitation, limb salvage and amputation, minimized damage of donor area, psychological rehabilitation, and multi-disciplinary cooperation of destructive electric burns. Only by attaching great importance to the functional reconstruction and rehabilitation, and embedding these concepts in people's brains, perfect repair and rehabilitation of destructive electric burns can be realized.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Procedimentos de Cirurgia Plástica , Humanos , Queimaduras por Corrente Elétrica/cirurgia , Cicatrização , Transplante de Pele , Salvamento de Membro , Queimaduras/cirurgia , Queimaduras/reabilitação
15.
Artigo em Chinês | MEDLINE | ID: mdl-37805781

RESUMO

High-voltage electric burn is one of burns that can cause severe damages to tissue and organs. Clinically, progressive injury in high-voltage electric burns is a key pathological change that affects the level of amputation and the success rate of treatment. At present, the exact definition and mechanism of progressive injury in high-voltage electric burns have not been elucidated, and the clinical treatment is mainly symptomatic treatment. Relevant research data on the mechanism and treatment of progressive injury in high-voltage electric burns are lacking. This paper analyzes and summarizes the mechanism, diagnosis, treatment, and common outcome of progressive injury in high-voltage electric burns, and provides a reference for the mechanism research, clinical diagnosis and treatment of progressive injury in high-voltage electric burns.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Humanos , Queimaduras por Corrente Elétrica/diagnóstico , Queimaduras por Corrente Elétrica/prevenção & controle , Queimaduras/terapia , Eletricidade , Transplante de Pele , Amputação Cirúrgica
16.
Artigo em Chinês | MEDLINE | ID: mdl-37805783

RESUMO

Objective: To investigate the treatment methods of upper limbs with destructive electric burns and its clinical efficacy. Methods: A retrospective observational study was conducted. From July 2014 to December 2020, 20 male patients with destructive electric burns in upper limbs who met the inclusion criteria were admitted to Tongren Hospital of Wuhan University & Wuhan Third Hospital, aged from 21 to 57 years, of whom 7 patients underwent emergency surgery, and a total of 20 affected limbs were treated with limb salvage. The necrotic bone was resected in 5 affected limbs, the residual hand and wrist at the distal end of left affected limb was replanted to the residual end of the right forearm in one patient in a cross heterotopic way, and short reduction and replantation after osteotomy were performed for two affected limbs with distal ulnar and radial necrosis. After thorough debridement, the area of wound proposed to be repaired by tissue flap was from 12 cm×7 cm to 58 cm×13 cm. According to the size and distribution of wound, the wounds of 2 affected limbs were repaired by transplantation of pedicled latissimus dorsi myocutaneous flap and free groin flap with vascular anastomosis. The wounds of the remaining 17 affected limbs were repaired with the transplantation of free latissimus dorsi myocutaneous flap, anterolateral thigh flaps, and paraumbilical perforator flap, with 10 affected limbs with larger wounds being jointly transplanted with the groin flap or the paraumbilical perforator flap on the other side. The total grafted tissue flap area was 20 cm×8 cm to 52 cm×20 cm. During tissue flap transplantation, according to the length of blood vessel defect in the affected limb, the distal artery of the affected limb was bridged with the distal part of flap vascular pedicle, undamaged vein on the affected side, superficial vein of abdominal wall, and great saphenous vein, etc., in 14 affected limbs, and the great saphenous vein was grafted in 3 of them with impeded distal return for recanalization of distal limb veins. The wound in the donor area was repaired by direct suture or grafting with split-thickness scalp. After the wound was basically healed, the functional rehabilitation training was started gradually, and the functional reconstruction and scar rectification surgery were started 3 months after tissue flap transplantation. The survival of tissue flaps/skin grafts, wound healing, limb salvage, and follow-up status after surgery were recorded. At the last follow-up, the function of the successfully salvaged limb was evaluated and scored by the disabilities of the arm, shoulder and hand (DASH) scoring scale. Results: After surgery, the grafted tissue flap in the affected limb and the skin grafts transplanted on the wound at flap donor site survived, and wounds at the recipient and donor sites healed well. Two affected limbs had distal necrosis within 10 days after tissue flap transplantation, and the middle and upper forearms were amputated. The remaining 18 affected limbs were successfully salvaged (including shortened replantation and cross heterotopic replantation). During 6-48 months of follow-up, 5 affected limbs that were successfully salvaged developed aseptic dissolution of residual tendon and bone tissue 3 to 18 months after tissue flap transplantation, which gradually healed after surgical debridement combined with vacuum sealing drainage treatment. At the last follow-up, the stump of two affected limbs healed well after amputation; 18 affected limbs that were successfully salvaged all survived well, of which 8 affected limbs had good recovery of finger flexion and extension function and thumb opponensplasty and could complete daily activities independently, 9 affected limbs regained partial mobility and could complete daily activities such as dressing and eating with the assistance of the opposite upper limb or auxiliary devices, and one affected limb had no function. At the last follow-up, the functional scores of DASH scoring scale of the 18 affected limbs that were successfully salvaged ranged from 30.0 to 100. Conclusions: Timely surgical debridement, proper treatment of the injured bone tissue, effective vascular bridging for reconstruction of the distal artery of the affected limb, and the use of blood-rich tissue flap to repair the wound, combined with early rehabilitation and functional restoration treatment, are beneficial to salvage the upper limb with destructive electric burns and improve the function of the affected limb.


Assuntos
Queimaduras por Corrente Elétrica , Salvamento de Membro , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Humanos , Masculino , Queimaduras por Corrente Elétrica/cirurgia , Necrose/cirurgia , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Resultado do Tratamento , Extremidade Superior/cirurgia , Cicatrização , Adulto Jovem , Adulto , Pessoa de Meia-Idade
17.
Artigo em Chinês | MEDLINE | ID: mdl-37805782

RESUMO

Objective: To explore the curative effects of foot microflap free transplantation in the repair of full-thickness electric burn wounds deep to tendon or even bone in fingers. Methods: A retrospective observational study was conducted. From July 2017 to February 2022, 20 patients with full-thickness electric burn wounds deep to tendon or even bone in fingers who met the inclusion criteria were admitted to Zhengzhou First People's Hospital, including 19 males and 1 female, aged 18 to 64 years. Among the 20 wounds, 15 wounds were located on the palm side, including 8 on the thumb, 5 on the index finger, and 2 on the middle finger; 5 wounds were located on the back, including 1 on the index finger and 4 on the middle finger. After debridement, the wound area ranged from 4.5 cm×2.0 cm to 7.0 cm×3.0 cm. According to the principle of tissue structure similarity, 10 wounds were repaired with plantar medial flaps, 5 wounds were repaired with hallux peroneal flaps, and 5 wounds were repaired with dorsalis pedis artery flaps, with flap area of 5.0 cm×2.5 cm-8.0 cm×3.5 cm. The flaps were transplanted freely and arteries and veins and/or nerves were anastomosed at the same time. The wound in the donor site was repaired with thigh medium-thick skin graft. The survival of flaps and skin grafts were observed after surgery. The appearance of flap, temperature and color of the distal end in the affected finger were observed during follow-up. At the last follow-up, the joint function and flap sensory recovery of the affected finger were evaluated with the trial standard for the evaluation of the functions of the upper limbs of the Hand Surgery Society of the Chinese Medical Association; the two-point discrimination distance of skin in the area of flaps with nerve anastomosis was measured; the satisfaction of patients with the curative effect was investigated by using the curative effect satisfaction rating scale, and the very satisfied rate was calculated; the repair effect of flap was evaluated by the comprehensive evaluation scale, and the excellent and good rate was calculated. Results: All the flaps and skin grafts survived after surgery. During the follow-up of 10-18 months after surgery, the appearance of flap was natural and not bloated; the temperature and color of the distal end in the affected finger were basically the same as that of normal finger skin. At the last follow-up, the function recovery of the affected finger joints was as follows: 11 affected fingers were within the normal range of motion, 6 affected fingers had their total active range of motion recovered to 85% of the healthy side, and 3 affected fingers had their total active range of motion recovered to 75% of the healthy side; the flap sensory recovery was as follows: the sense of 15 flaps with nerve anastomosis all recovered to grade S3+, and the two-point discrimination distance of skin in the flap area was 7.0-9.0 mm; the sense of 1 flap without nerve anastomosis recovered to grade S2 and the sense of 4 flaps recovered to grade S1. The satisfaction with curative effect of 20 patients was very satisfied in 16 cases and moderately satisfied in 4 cases, with the very satisfied rate of 80%; the repair result of 20 flaps was excellent in 16 cases, good in 2 cases, and fair in 2 cases, with excellent and good rate of 90%. Conclusions: Due to the similar tissue structure of donor site and recipient site, foot microflap free transplantation in the repair of full-thickness electric burn wounds deep to tendon or even bone in fingers can achieve good appearance and function, with better functional and sensory recovery of the affected finger in the case of nerve anastomosis. Patients have high degree of satisfaction with the curative effects, which is worthy of promotion.


Assuntos
Queimaduras por Corrente Elétrica , Queimaduras , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Feminino , Humanos , Masculino , Queimaduras/cirurgia , Queimaduras por Corrente Elétrica/cirurgia , Retalho Perfurante/transplante , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Retalhos Cirúrgicos , Tendões/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
18.
Artigo em Chinês | MEDLINE | ID: mdl-37805784

RESUMO

Objective: To establish and validate a risk prediction model of disseminated intravascular coagulation (DIC) by the screening independent risk factors for the occurrence of DIC in patients with electrical burns. Methods: The retrospective case series study was conducted. The clinical data of 218 electrical burn patients admitted to Baogang Hospital of Inner Mongolia from January 2015 to January 2023 who met the inclusion criteria were collected, including 198 males and 20 females, with the age of (38±14) years. The patients were divided into DIC group and non DIC group based on whether they were diagnosed with DIC during the treatment period. The following data of patients of two groups were collected and compared, including age, gender, total burn area, full-thickness burn area, injury voltage, whether osteofascial compartment syndrome occurred within 1 day after injury, duration of stay in burn intensive care unit, total length of hospital stay, whether combined with inhalation injury and multiple injuries, whether shock occurred upon admission, the abbreviated burn severity index score, and the acute physiology and chronic health evaluation Ⅱ score. The laboratory examination data of the patients within 24 hours after admission were also collected, including blood routine indexes: white blood cell count (WBC), hemoglobin level, platelet count (PLT), and neutrophil count; coagulation indexes: activated partial thromboplastin time (APTT), prothrombin time, thrombin time, and levels of D-dimer and fibrinogen (FIB); blood biochemistry indexes: aspartic transaminase, alanine transaminase, direct bilirubin, total bilirubin, total protein, albumin, blood glucose, creatinine, and urea nitrogen; blood gas analysis indexes: blood pH value, arterial partial pressure of oxygen, arterial partial pressure of carbon dioxide, bicarbonate, and base excess; and cardiac zymogram indexes: levels of myoglobin, troponin, lactate dehydrogenase, creatine kinase (CK), and α-hydroxybutyrate dehydrogenase. Data were statistically analyzed with chi-square test, Fisher's exact probability test, independent sample t test, and Mann-Whitney U test. For the variables with statistically significant differences in single factor analysis, the least absolute value selection and shrinkage operator (LASSO) regression was used to reduce the dimension, and the predictive factors for DIC in 218 patients with electrical burns were screened. The above-mentioned predictors were included in multivariate logistic regression analysis to find out the independent risk factors for DIC in 218 patients with electrical burns, and to draw the prediction model nomograms. The performance of the prediction model was evaluated by the receiver operating characteristic (ROC) curve and the area under the ROC curve, and the prediction model was validated by the calibration curve and clinical decision curve analysis (DCA). Results: Compared with those in non DIC group, the total burn area, full-thickness burn area, total length of hospital stay, and the proportions of high voltage caused injury, occurrence of osteofascial compartment syndrome within 1 day after injury, combination of inhalation injury, and occurrence of shock upon admission of patients in DIC group were significantly increased/prolonged (with Z values of -2.53, -4.65, and -2.10, respectively, with χ2 values of 11.46, 16.00, 7.98, and 18.93, respectively, P<0.05). Compared with those in non DIC group, the APTT, level of D-dimer, myoglobin, WBC, PLT, and levels of FIB, total bilirubin, and CK of patients within 24 hours after admission in DIC group were significantly prolonged/increased (with Z values of -2.02, -4.51, and -3.82, respectively, with t values of -3.84, -2.34, -2.77, -2.70, and -2.61, respectively), and the level of total protein and blood pH value were significantly reduced (t=-2.85, Z=-2.03), P<0.05. LASSO regression analysis was carried out for the above 17 indicators with statistically significant differences. The results showed that injury voltage, the occurrence of shock upon admission, the occurrence of osteofascial compartment syndrome within 1 day after injury, and levels of D-dimer and total protein within 24 hours after admission were predictive factors for the occurrence of DIC in 218 patients with electrical burns (with regression coefficients of 0.24, 0.52, 0.35, 0.13, and -0.001, respectively). Multivariate logistic regression analysis showed that injury voltage, the occurrence of shock upon admission, the occurrence of osteofascial compartment syndrome within 1 day after injury, and D-dimer level within 24 hours after admission were independent risk factors for DIC in 218 patients with electrical burns (with odds ratios of 3.33, 4.24, 2.68, and 1.38, respectively, with 95% confidence intervals of 1.43-7.79, 1.78-10.07, 1.17-6.13, and 1.19-1.61, respectively, P<0.05). Based on the aforementioned four independent risk factors, the nomogram of prediction model for evaluating the probability of DIC in patients was drawn. The area under the ROC curve of prediction model was 0.88, and the 95% confidence interval was 0.82-0.95, indicating that the model had good predictive ability; the curve of prediction model tended to be near the ideal curve, indicating that the model had a high calibration degree; the clinical DCA of prediction model showed that the threshold probability of patients ranged from 4% to 97%, indicating that the model had good predictive ability. Conclusions: The injury voltage, the occurrence of shock upon admission, the occurrence of osteofascial compartment syndrome within 1 day after injury, and D-dimer level within 24 hours after admission are independent risk factors for the occurrence of DIC in patients with electrical burns. The prediction model established based on the above indicators can provide early warning for the occurrence of DIC in these patients.


Assuntos
Queimaduras por Corrente Elétrica , Síndromes Compartimentais , Coagulação Intravascular Disseminada , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Coagulação Intravascular Disseminada/etiologia , Mioglobina , Curva ROC , Bilirrubina , Prognóstico
19.
Artigo em Chinês | MEDLINE | ID: mdl-37805797

RESUMO

Objective: To explore the curative effects of medial plantar free flap in reconstructing electric burn wound and scar contracture in the palm. Methods: A retrospective observational study was conducted. From January 2020 to January 2023, 6 patients with electric burn wounds or scar contracture in the palm who met the inclusion criteria were admitted to the First Affiliated Hospital of Air Force Medical University, including 5 males and 1 female, aged 35 to 55 years. The wound area was 5.0 cm×3.0 cm-8.0 cm×7.0 cm after the debridement of electric burn wounds or resection of scar in the palm. The medial plantar free flap anastomosed with cutaneous nerve was used for wound reconstruction, with flap area of 5.5 cm×3.5 cm-8.5 cm×7.5 cm. The wound in the donor site was repaired with transplantation of abdominal full-thickness skin graft. After surgery, the survival of flaps and skin grafts were observed, the shape and texture of flap and the recovery of donor site of flap were observed, and the holding function of the affected hand was assessed. At the last follow-up, the two-point discrimination distance of flap was measured, the sensory recovery of flap was evaluated with the trial standard for the evaluation of the functions of the upper limbs of the Hand Surgery Society of the Chinese Medical Association, and the function recovery of flap was evaluated by post-surgery flap function evaluation scale. Results: After surgery, 5 flaps survived well, while the distal part of 1 flap was partially necrotic, which was repaired by medium-thickness skin graft from lateral thigh after debridement. All the skin grafts at the donor sites survived well. During follow-up of 3 to 24 months, the flap was not bloated, the texture and color were good, the match with the surrounding tissue was high, with no obvious scar contracture occurred at the donor site. The affected hand had good holding function. At the last follow-up, the two-point discrimination distance of flap was 6-8 mm, the flap sensation recovery was as follows: 5 flaps recovered to grade S3+, 1 flap recovered to grade S3, and the functional evaluation of flaps was excellent in 5 cases and good in 1 case. The patients basically returned to normal life and work. Conclusions: The medial plantar free flap with cutaneous nerve anastomosis has many advantages, such as high matching degree of appearance, good sensory recovery, and holding function of the affected hand. It is an ideal choice for the reconstruction of the electric burn wound and scar contracture in the palm.


Assuntos
Queimaduras por Corrente Elétrica , Contratura , Retalhos de Tecido Biológico , Retalho Perfurante , Lesões dos Tecidos Moles , Feminino , Humanos , Masculino , Queimaduras por Corrente Elétrica/cirurgia , Cicatriz/cirurgia , Contratura/etiologia , Contratura/cirurgia , Mãos/cirurgia , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
20.
J Wound Care ; 32(Sup10): ccxix-ccxxiv, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37830804

RESUMO

OBJECTIVE: In this study, the aim was to discuss the effects of seasonal changes on the patient profile and number of patients hospitalised at our burn centre. METHOD: All cases of burns that occurred between 1 January 2014 and 1 January 2020 at our hospital were investigated. RESULTS: In total, 1417 patients were investigated, 799 of whom were male (56.4%) and 618 (43.6%) were female. The number of patients with burns in the 1-4 years age group was the highest of all the age groups. Scald burns and electrical burns were mostly observed in the spring; flame burns were mostly observed in the winter, and hot object contact and chemical burns were mostly observed in the summer. When considered in total, burn cases were mostly observed in spring and autumn. CONCLUSION: Understanding seasonal epidemiology of burn injuries can facilitate seasonal injury prevention campaigns and education efforts. Burn centres can also allocate resources appropriately, according to the patient volume and possible burn outcomes for each season.


Assuntos
Queimaduras Químicas , Queimaduras por Corrente Elétrica , Humanos , Masculino , Feminino , Tempo de Internação , Estações do Ano , Hospitais , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...