Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28.238
Filtrar
1.
Circ Cardiovasc Interv ; 17(4): e013196, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38626077

RESUMO

BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P=0.02) and remodeling techniques (0.30±0.15 N; P=0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P=0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P=0.02) and triangular resectional techniques (0.36±0.27 N; P=0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P=0.02) or 6 neochordae (0.19±0.16 N; P=0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae (P=0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P=0.01) and 2 neochordae (0.29±0.18 N; P=0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Masculino , Animais , Ovinos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cordas Tendinosas/cirurgia , Resultado do Tratamento
2.
Circ Cardiovasc Imaging ; 17(4): e016435, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38626096

RESUMO

Heart valve replacement has steadily increased over the past decades due to improved surgical mortality, an aging population, and the increasing use of transcatheter valve technology. With these developments, prosthetic valve complications, including prosthetic valve endocarditis, are increasingly encountered. In this review, we aim to characterize the manifestations of prosthetic valve endocarditis using representative case studies from our institution to highlight the advances and contributions of modern multimodality imaging techniques.


Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Idoso , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/terapia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Imagem Multimodal , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/terapia
3.
J Am Heart Assoc ; 13(8): e032929, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38563385

RESUMO

BACKGROUND: TRI-SCORE was recently developed in Europe as a risk model for predicting in-hospital death after isolated tricuspid valve surgery. We aimed to validate TRI-SCORE in an Asian population and investigate its value for predicting long-term outcomes. METHODS AND RESULTS: The TRI-SCORE was calculated for 202 patients (65±11 years, 61% women, 81% functional tricuspid regurgitation) who underwent isolated tricuspid valve surgery for severe tricuspid regurgitation at 2 Korean centers and was based on 8 parameters: age, New York Heart Association class, right-sided heart failure signs, furosemide daily dose, glomerular filtration rate, bilirubin, left ventricular ejection fraction, and moderate/severe right ventricular dysfunction. The primary outcome was all-cause death during follow-up; the secondary outcome was in-hospital death. During a median follow-up duration of 50 (interquartile range, 21-82) months after isolated tricuspid valve surgery, 23 (11.4%) patients experienced the primary outcome, and 7 (3.5%) patients experienced the secondary outcome. Observed all-cause death and in-hospital death increased by up to 50% in those with higher scores. Patients with the primary outcome had a higher TRI-SCORE (4.5±2.4 versus 2.9±2.1; P=0.001) than those without. The TRI-SCORE showed a significant association with the primary outcome (concordance index, 0.77, cutoff value, 4) and in-hospital death (area under the curve, 0.84; cutoff value, 3). Using the Kaplan-Meier analysis, patients with a high TRI-SCORE exhibited a poor outcome for all-cause death at follow-up (log-rank P<0.001) and in-hospital death (log-rank P=0.004). CONCLUSIONS: TRI-SCORE was validated in an Asian population and helped predict long-term outcomes after isolated tricuspid valve surgery.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Resultado do Tratamento , Volume Sistólico , Mortalidade Hospitalar , Função Ventricular Esquerda , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos
4.
J Am Heart Assoc ; 13(8): e033510, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38567665

RESUMO

BACKGROUND: Pulmonary hypertension (PH) and secondary mitral regurgitation (MR) are associated with adverse outcomes after mitral transcatheter edge-to-edge repair. We aim to study the prognostic value of invasively measured right ventricular afterload in patients undergoing mitral transcatheter edge-to-edge repair. METHODS AND RESULTS: We identified patients who underwent right heart catheterization ≤1 month before transcatheter edge-to-edge repair. The end points were all-cause mortality and a composite of mortality and heart failure hospitalization at 2 years. Using the receiver operating characteristic curve-derived threshold of 0.6 for pulmonary effective arterial elastance ([Ea], pulmonary artery systolic pressure/stroke volume), patients were stratified into 3 profiles based on PH severity (low elastance [HE]: Ea <0.6/mean pulmonary artery pressure (mPAP)) <35; High Elastance with No/Mild PH (HE-): Ea ≥0.6/mPAP <35; and HE with Moderate/Severe PH (HE+): Ea ≥0.6/mPAP ≥35) and MR pathogenesis (Primary MR [PMR])/low elastance, PMR/HE, and secondary MR). The association between this classification and clinical outcomes was examined using Cox regression. Among 114 patients included, 50.9% had PMR. Mean±SD age was 74.7±10.6 years. Patients with Ea ≥0.6 were more likely to have diabetes, atrial fibrillation, New York Heart Association III/IV status, and secondary MR (all P<0.05). Overall, 2-year cumulative survival was 71.1% and was lower in patients with secondary MR and mPAP ≥35. Compared with patients with low elastance, cumulative 2-year event-free survival was significantly lower in HE- and HE+ patients (85.5% versus 50.4% versus 41.0%, respectively, P=0.001). Also, cumulative 2-year event-free survival was significantly higher in patients with PMR/low elastance when compared with PMR/HE and patients with secondary mitral regurgitation (85.5% versus 55.5% versus 46.1%, respectively, P=0.005). CONCLUSIONS: Assessment of the preprocedural cardiopulmonary profile based on mPAP, MR pathogenesis, and Ea guides patient selection by identifying hemodynamic features that indicate likely benefit from mitral-transcatheter edge-to-edge repair in PH or lack thereof.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prognóstico , Insuficiência da Valva Mitral/cirurgia , Hemodinâmica , Cateterismo Cardíaco/efeitos adversos , Artéria Pulmonar , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
6.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38569760

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adulto , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Sistema de Registros , Desenho de Prótese , Estudos Retrospectivos
9.
J Cardiothorac Surg ; 19(1): 164, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561823

RESUMO

BACKGROUND: Mitral regurgitation is a frequent valvular disease, with an increasing prevalence. We analyzed the short-term outcomes of mitral valve repair procedures conducted in our clinic using a new semirigid annuloplasty ring featuring a gradual saddle shape design. METHODS: We retrospectively analyzed mitral valve repair surgeries performed at our Institution between December 2019 and November 2021 with the MEMO 4D semirigid annuloplasty ring. RESULTS: In total, 53 patients were included in the study. Mean patient age was 63.6 ± 11.7 years. Most patients presented with degenerative mitral valve regurgitation (N = 44; 83%). The grade of mitral regurgitation was equal or more than 3 + in 98.1% of the patients (N = 52). The most used ring size was size 34 mm (N = 30, 56.6%). There was no intraoperative or hospital mortality. No cases of stroke, bleeding, endocarditis or other major complications occurred. At discharge, most patients were in NYHA class I. Postoperative echocardiographic results showed no (90.6%) or 1+ (5.7%) mitral valve regurgitation. Only 1 patient (1.9%) presented with mitral valve regurgitation grade 2+. Mean postoperative transvalvular gradient was low (mean = 3.3 ± 1.2 mmHg). No cases of LVOT obstruction or systolic anterior motion occurred. CONCLUSIONS: Our series showed excellent mitral valve competency and very satisfactory early clinical outcomes. The transesophageal echocardiographic follow-up, despite obtained in a limited number of patients, further confirmed the effectiveness of findings of this preliminary experience.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Anuloplastia da Valva Mitral/efeitos adversos , Ecocardiografia , Resultado do Tratamento
10.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589959

RESUMO

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Assuntos
Bioprótese , Endocardite , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Micoses , Masculino , Humanos , Adulto Jovem , Adulto , Valva Aórtica/cirurgia , Aorta Torácica/cirurgia , Aorta/cirurgia , Endocardite/diagnóstico , Endocardite/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Bioprótese/efeitos adversos
11.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594705

RESUMO

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Valva Aórtica/cirurgia , Resultado do Tratamento
12.
Braz J Cardiovasc Surg ; 39(3): e20230108, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569069

RESUMO

INTRODUCTION: This study aimed to compare the early postoperative outcomes of right anterior thoracotomy minimally invasive aortic valve replacement (RAT-MIAVR) surgery with those of median full sternotomy aortic valve replacement (MFS-AVR) approach with the goal of identifying potential benefits or drawbacks of each technique. METHODS: This retrospective, observational, cohort study included 476 patients who underwent RAT-MIAVR or MFS-AVR in our hospital from January 2015 to January 2023. Of these, 107 patients (22.5%) underwent RAT-MIAVR, and 369 patients (77.5%) underwent MFS-AVR. Propensity score matching was used to minimize selection bias, resulting in 95 patients per group for analysis. RESULTS: After propensity matching, two groups were comparable in preoperative characteristics. RAT-MIAVR group showed longer cardiopulmonary bypass time (130.24 ± 31.15 vs. 117.75 ± 36.29 minutes, P=0.012), aortic cross-clamping time (76.44 ± 18.00 vs. 68.49 ± 19.64 minutes, P=0.004), and longer operative time than MFS-AVR group (358.47 ± 67.11 minutes vs. 322.42 ± 63.84 minutes, P=0.000). RAT-MIAVR was associated with decreased hospitalization time after surgery, lower postoperative blood loss and drainage fluid, a reduced incidence of mediastinitis, increased left ventricular ejection fraction, and lower pacemaker use compared to MFS-AVR. However, there was no significant difference in the incidence of major complications and in-hospital mortality between the two groups. CONCLUSION: RAT-MIAVR is a feasible and safe alternative procedure to MFS-AVR, with comparable in-hospital mortality and early follow-up. This minimally invasive approach may be a suitable option for patients requiring isolated aortic valve replacement.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Esternotomia/métodos , Toracotomia/métodos , Estudos Retrospectivos , Estudos de Coortes , Pontuação de Propensão , Volume Sistólico , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Tempo de Internação , Função Ventricular Esquerda
13.
JACC Cardiovasc Interv ; 17(7): 837-858, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599687

RESUMO

Severe tricuspid regurgitation (TR) is a progressive condition associated with substantial morbidity, poor quality of life, and increased mortality. Patients with TR commonly have coexisting conditions including congestive heart failure, pulmonary hypertension, chronic lung disease, atrial fibrillation, and cardiovascular implantable electronic devices, which can increase the complexity of medical and surgical TR management. As such, the optimal timing of referral for isolated tricuspid valve (TV) intervention is undefined, and TV surgery has been associated with elevated risk of morbidity and mortality. More recently, an unprecedented growth in TR treatment options, namely the development of a wide range of transcatheter TV interventions (TTVI) is stimulating increased interest and referral for TV intervention across the entire medical community. However, there are no stepwise algorithms for the optimal management of symptomatic severe TR before TTVI. This article reviews the contemporary assessment and management of TR with addition of a medical framework to optimize TR before referral for TTVI.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Qualidade de Vida , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
15.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599690

RESUMO

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Cateterismo Cardíaco/métodos
17.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Cateterismo Cardíaco/métodos
19.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599692

RESUMO

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seguimentos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...