Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.983
Filtrar
1.
Clin Exp Dent Res ; 10(2): e879, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38558512

RESUMO

BACKGROUND: Orthodontic treatment is often accompanied by discomfort and pain in patients, which are believed to be a result of orthodontic tooth displacement caused by the mechanical forces exerted by the orthodontic appliances on the periodontal tissues. These lead to change blood oxygen level dependent response in related brain regions. OBJECTIVE: This systematic review aims to assess the impact of experimental orthodontic tooth displacement on alterations in central nervous system activation assessed by tasked based and resting state fMRI. MATERIALS AND METHODS: A literature search was conducted using online databases, following PRISMA guidelines and the PICO framework. Selected studies utilized magnetic resonance imaging to examine the brain activity changes in healthy participants after the insertion of orthodontic appliances. RESULTS: The initial database screening resulted in 791 studies. Of these, 234 were duplicates and 547 were deemed irrelevant considering the inclusion and exclusion criteria. Of the ten remaining potential relevant studies, two were excluded during full-text screening. Eight prospective articles were eligible for further analysis. The included studies provided evidence of the intricate interplay between orthodontic treatment, pain perception, and brain function. All of the participants in the included studies employed orthodontic separators in short-term experiments to induce tooth displacement during the early stage of orthodontic treatment. Alterations in brain activation were observed in brain regions, functional connectivity and brain networks, predominantly affecting regions implicated in nociception (thalamus, insula), emotion (insula, frontal areas), and cognition (frontal areas, cerebellum, default mode network). CONCLUSIONS: The results suggest that orthodontic treatment influences beyond the pain matrix and affects other brain regions including the limbic system. Furthermore, understanding the orthodontically induced brain activation can aid in development of targeted pain management strategies that do not adversely affect orthodontic tooth movement. Due to the moderate to serious risk of bias and the heterogeneity among the included studies, further clinical trials on this subject are recommended.


Assuntos
Imageamento por Ressonância Magnética , Má Oclusão , Humanos , Estudos Prospectivos , Técnicas de Movimentação Dentária/efeitos adversos , Técnicas de Movimentação Dentária/métodos , Dor/etiologia , Encéfalo/diagnóstico por imagem
2.
Clin Oral Investig ; 28(5): 258, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637429

RESUMO

OBJECTIVES: To investigate the effects of material type and thickness on force generation and distribution by aligners. MATERIALS AND METHODS: Sixty aligners were divided into six groups (n = 10): one group with a thickness of 0.89 mm using Zendura Viva (Multi-layer), four groups with a thickness of 0.75 mm using Zendura FLX (Multi-layer), CA Pro (Multi-layer), Zendura (Single-layer), and Duran (Single-layer) sheets, and one group with a thickness of 0.50 mm using Duran sheets. Force measurements were conducted using Fuji® pressure-sensitive films. RESULTS: The lowest force values, both active and passive, were recorded for the multi-layered sheets: CA Pro (83.1 N, 50.5 N), Zendura FLX (88.9 N, 60.7 N), and Zendura Viva (92.5 N, 68.5 N). Conversely, the highest values were recorded for the single-layered sheets: Duran (131.9 N, 71.8 N) and Zendura (149.7 N, 89.8 N). The highest force was recorded at the middle third of the aligner, followed by the incisal third, and then the cervical third. The net force between the incisal and cervical thirds (FI-FC) showed insignificant difference across different materials. However, when comparing the incisal and middle thirds, the net force (FI-FM) was higher with single-layered materials. Both overall force and net force (FI-FM) were significantly higher with 0.75 mm compared to those with a thickness of 0.50 mm. CONCLUSIONS: Multi-layered aligner materials exert lower forces compared to their single-layered counterparts. Additionally, increased thickness in aligners results in enhanced retention and greater force generation. For effective bodily tooth movement, thicker and single-layered rigid materials are preferred. CLINICAL RELEVANCE: This research provides valuable insights into the biomechanics of orthodontic aligners, which could have significant clinical implications for orthodontists. Orthodontists might use this information to more effectively tailor aligner treatments, considering the specific tooth movement required for each individual patient. In light of these findings, an exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol proposes alternating between multi-layered and single-layered materials within the same treatment phase. This strategy is suggested to optimize treatment outcomes, particularly when planning for a bodily tooth movement.


Assuntos
Desenho de Aparelho Ortodôntico , Técnicas de Movimentação Dentária , Humanos , Fenômenos Biomecânicos , Resultado do Tratamento , Técnicas de Movimentação Dentária/métodos
3.
Angle Orthod ; 94(3): 280-285, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639458

RESUMO

OBJECTIVES: To survey treatment-planning practices of orthodontists related to the Invisalign Lite clear aligner appliance (Align Technology, San Jose, Calif). MATERIALS AND METHODS: Patients satisfying inclusion and exclusion criteria and treated with Invisalign Lite were selected from a database containing more than 17,000 patients. Relevant data regarding treatment-planning practices were obtained from Align Technology's treatment-planning facility, ClinCheck, and evaluated. RESULTS: Most (n = 135; 79.9%) patients were female and had a median (interquartile range [IQR]) age of 30.5 (23.8, 43.1) years. The median (IQR) number of aligners for the sample was 23.0 (14, 28) for the maxilla and 24 (14, 28) for the mandible. Most (n = 122; 72.2%) patients required at least one additional series of aligners. More locations for interproximal reduction (IPR) were prescribed in the mandible (mean 1.91 [1.78]) than in the maxilla (1.03 [1.78]; P < .024) in the initial accepted plan of all patients. More teeth were prescribed composite resin (CR) attachments in the maxilla (P < .0001) in the initial accepted plan of all patients. Issues regarding tooth position protocols (n = 50; 53.3%) and requirement for additional IPR (n = 68; 45.3%) were reasons for treatment plan changes before acceptance of the initial treatment plan by orthodontists. CONCLUSIONS: More than 7 of 10 patients required at least one additional series of aligners after the initial series of Invisalign Lite aligners was completed. Prescription of IPR was more common in the mandible, and prescription of CR attachments was more common in the maxilla.


Assuntos
Aparelhos Ortodônticos Removíveis , Técnicas de Movimentação Dentária , Humanos , Feminino , Masculino , Estudos Transversais , Ortodontistas , Maxila , Resinas Compostas
4.
BMC Oral Health ; 24(1): 424, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582881

RESUMO

INTRODUCTION: Neodymium-iron-boron magnets have been suggested as a contemporary method for accelerating the process of orthodontic tooth movement (OTM). A limited number of clinical trials evaluated their effectiveness in accelerating OTM which is desirable for both orthodontists and patients. The present study aimed to investigate the effectiveness of a low-intensity static magnetic field (SMF) in accelerating upper canine retraction movement. MATERIALS AND METHODS: Seventeen patients (mean age 20.76 ± 2.9 years) with their orthodontic treatment decision to extract the upper and lower first premolars due to bimaxillary protrusion malocclusion were included in this split-mouth study. Canine retraction was performed using Nickel-titanium (Ni-Ti) closed-coil springs (150 g of force on each side). The experimental side received SMF via an auxiliary wire that carried 4-neodymium iron-born magnets with an air gap of 2 mm between the magnets to produce a magnetic field density of 414 mT in the region corresponding to the lateral ligament of the upper canine. To determine the rate of upper canine retraction and upper molar drift, alginate impressions were taken once a month to create plaster casts, which were analyzed digitally via a three-dimensional method. RESULTS: The rate of upper canine retraction was significantly greater (P < 0.05) on the SMF side than that on the control side during the first and second months, with an overall duration (19.16%) that was greater than that on the control side. The peak acceleration occurred during the second month (38.09%). No significant differences in upper molar drift were detected between the experimental and control sides (P > 0.05). CONCLUSION: A low-intensity static magnetic field was effective at accelerating upper canine retraction. The difference between the two sides was statistically significant but may not be clinically significant. The SMF did not affect upper molar drift during the upper canine retraction phase. TRIAL REGISTRATION: The trial was retrospectively registered at the ISRCTN registry ( ISRCTN59092624 ) (31/05/2022).


Assuntos
Má Oclusão , Neodímio , Humanos , Adolescente , Adulto Jovem , Adulto , Fios Ortodônticos , Boca , Técnicas de Movimentação Dentária/métodos , Ferro , Dente Canino
5.
Sci Rep ; 14(1): 7952, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575623

RESUMO

To investigate the effectiveness of AcceleDent Aura vibrating device on the rate of canine retraction. Thirty-two patients requiring extraction of upper first premolars and canine retraction were randomly allocated with a 1:1 ratio into either no-appliance group or the AcceleDent Aura appliance group. Canine retraction was done applying 150gm of retraction force using NiTi coil springs on 16 × 22 stainless steel archwires. The duration of the study was 4 months. Models were collected and digitized directly after extraction of upper first premolars and at monthly intervals during canine retraction for recording the monthly as well as the total distance moved by the canine. Digitized models were superimposed on the initial model and data were statistically analyzed. Anchorage loss, rotation, tipping, torque and root condition were evaluated using cone beam computed tomography imaging. Pain was evaluated by visual analog scale. No patients were dropped-out during this study. There was no statistically significant difference between both groups regarding the total distance travelled by the canine (P = 0.436), as well as the rate of canine retraction per month (P = 0.17). Root condition was the same for the two groups. Regarding the pain level, there was no statistically significant difference between the two groups at day 0 (P = 0.721), after 24 h (P = 0.882), after 72 h (P = 0.378) and after 7 days (P = 0.964). AcceleDent Aura was not able to accelerate orthodontic tooth movement. Pain level couldn't be reduced by vibrational force with an AcceleDent device during orthodontic treatment. Root condition was not affected by the vibrational forces.


Assuntos
Epilepsia , Vibração , Humanos , Vibração/uso terapêutico , Dente Canino/diagnóstico por imagem , Técnicas de Movimentação Dentária/métodos , Dor
6.
Biomolecules ; 14(3)2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38540720

RESUMO

A recent study reported that micro-osteoperforations (MOPs) accelerated tooth movement by activating alveolar bone remodeling. However, very little is known about the relationship between MOPs and external apical root resorption during orthodontic treatment. In this study, in order to investigate the mechanism through which MOPs accelerate tooth movement without exacerbating the progression of root resorption, we measured the volume of the resorbed root, and performed the terminal deoxynucleotidyl transferase (TdT)-mediated dUTP-biotin nick-end labeling (TUNEL) method on exposed MOPs during experimental tooth movements in rats. Male Wistar rats (11 weeks old) were divided into three groups: 10 g orthodontic force (optimal force) applied to the maxillary first molar (optimal force: OF group), 50 g orthodontic force application (heavy force: HF group), and 10 g force application plus three small perforations of the cortical plate (OF + MOPs group). On days 1, 4, 7, 10, and 14 after force application, the tooth movement and root volume were investigated by micro-computed tomography. Furthermore, the number of apoptotic cells in the pressured sides of the periodontal ligament (PDL) and surrounding hard tissues were determined by TUNEL staining. The OF + MOPs group exhibited a 1.8-fold increase in tooth movement on days 7, 10, and 14 compared with the OF group. On days 14, the HF group had a higher volume of root loss than the OF and OF + MOPs groups. On the same day, the number of TUNEL-positive cells in the HF group increased at the root (cementum) site whereas that in the OF group increased at the alveolar bone site. Furthermore, the number of TUNEL-positive cells in the OF + MOPs group increased at the alveolar bone site compared with the OF group. These results suggest that MOPs accelerate orthodontic tooth movement without exacerbating the progression of root resorption.


Assuntos
Reabsorção da Raiz , Ratos , Masculino , Animais , Ratos Wistar , Técnicas de Movimentação Dentária/métodos , Microtomografia por Raio-X , Marcação In Situ das Extremidades Cortadas
13.
Clin Oral Investig ; 28(4): 236, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556610

RESUMO

OBJECTIVES: Anterior open bite can be treated non-surgically via molar intrusion using temporary skeletal devices (TAD). Clear aligner therapy (CAT) is recognized as a viable therapeutic modality for non-extraction treatment of adults with mild open bite. This study aimed to compare the treatment effect and mechanisms of open bite closure between patients treated with braces and TADs double arch intrusion and those treated with CAT. Treatment success at T3 was based on 1- positive overbite on ceph; 2- Change in the vertical dimension 3- post treatment POSI score equal to zero. MATERIAL AND METHODS: The TAD group includes 18 consecutively treated patients from the main author. The CAT group consisted of 16 selected patients from three different orthodontists. The observation time points were as follows: pretreatment (T1), end of molar intrusion and positive overbite achieved (T2), end of treatment (T3), at least 6-month follow-up (T4). Treatment changes were assessed by cephalometric analysis and frontal intraoral photo. RESULTS: At the end of treatment, 100% of the patient of the TAD group and 78,6% of the CAT group had a posi score of 0. The TAD group showed a significant reduction in vertical measurements (SN-MPA: -1,55° ± 0.41, LAFH: -3,05 ± 0.51 mm, U6-PP: -1.48 ± 0.30 mm), but the CAT group did not have significant changes for these variables. Both groups had significant increases in overbite from T1 to T3 (TAD: 4,32 ± 0,5 mm; CAT: 2,33 ± 0.56 mm), and overbite remained stable at T4. The CAT group did not have a significant upper molar intrusion, but a significant extrusion of 1.22 ± 0.42 mm of the lower incisor occurred. CONCLUSION: The TAD group achieved bite closure by upper molar intrusion, lower molar and incisors vertical control, and mandibular plane counterclockwise rotation, resulting in an improved AP and vertical relationship. The CAT group achieved bite closure through the lower incisor extrusion without significant change in the vertical dimension. CLINICAL RELEVANCE: This study provides relevant information about the skeletal and dental changes of open bite treatment with TADs double arch intrusion. The comparison with a control group treated with CAT confirms known information.


Assuntos
Má Oclusão Classe II de Angle , Mordida Aberta , Aparelhos Ortodônticos Removíveis , Sobremordida , Adulto , Humanos , Mordida Aberta/terapia , Tratamento Conservador , Mandíbula , Cefalometria/métodos , Técnicas de Movimentação Dentária , Maxila
14.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(4): 400-406, 2024 Apr 09.
Artigo em Chinês | MEDLINE | ID: mdl-38548599

RESUMO

Improper diagnosis and design, misusing orthodontic technique, relapse after orthodontic treatment, and poor patient compliance may lead to treatment failure, requiring orthodontic retreatment. While in such cases, patients usually have already had their teeth extracted, or are with periodontal, joint, and other dental problems, which often require multidisciplinary treatment. The retreatment of orthodontic patients is difficult, and the treatment options are limited. The characteristics of clear aligner treatment, such as comfortable and beautiful appearance, high degree of digital precision, and personalized tooth arrangement to simulate the final outcome, make it popular in the orthodontic retreatment. This article discusses and summarizes the details of orthodontic design, case monitoring, and the application of clear aligner in orthodontic retreatment of failed cases. Before starting treatment, the difficulty assessment tool (clear aligner treatment complexity assessment tool) can be used to evaluate the difficulty of clear aligner treatment. Orthodontists are recommended to treat orthodontic patients with clear aligners within their ability to avoid treatment failure. The key to the success of the extraction case treatment with clear aligner is to make the correct diagnosis and select the right cases. In the treatment planning, attention should be paid to the restoration of anterior tooth torque, making good use of molar distalization to obtain the space, vertical control, and improving posterior tooth relationship. Proper selection of cases and reasonable design in clear aligner treatment are expected to obtain tooth alignment, good intercuspation, normal overbite and overjet, periodontal health, parallel roots, and to achieve the goal of aesthetic, functional, stable, and healthy orthodontic treatment.


Assuntos
Estética Dentária , Aparelhos Ortodônticos Removíveis , Humanos , Técnicas de Movimentação Dentária , Assistência Odontológica , Retratamento
15.
BMC Oral Health ; 24(1): 338, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491450

RESUMO

BACKGROUND: Refinements are very common in clear aligner treatments. The aim of this study is to assess whether the predictability of deep overbite correction is similar over several refinements using clear aligners (Invisalign, Align Technology, San Jose, Calif) and examine the accuracy of vertical movement and inclination change of individual teeth. METHODS: This retrospective study included 20 deep bite patients (7M and 13F; 32.63 ± 11.88 years old; an initial overbite of 5.09 ± 0.98 mm), consecutively treated from September 2016 and March 2023, who completed at least two sets of aligners, including refinements. The initial, predicted, and achieved models were exported from ClinCheck or OrthoCAD (Cadent Inc, Carlstadt, NJ) and superimposed via best-fit surface-based registration using SlicerCMF (version 4.9.0; cmf.slicer.org). We also examined 15 out of 20 patients who completed treatments. The overbite correction and changes in vertical movement and inclination for individual teeth were measured. Descriptive statistics and a paired t-test or Wilcoxon signed-rank test were performed. P < 0.05 was considered statistically significant. RESULTS: The mean accuracy of overbite correction was 37.63% after 1st set, followed by 11.19%, 6.32%, and 13.80% (2nd-4th sets), respectively. There were statistically significant differences between the predicted and achieved vertical movements and inclination changes for all teeth for the 1st and 2nd sets. For the completed cases, the mean overbite correction was 38.54% compared to the initially planned overbite correction, which is similar to one of the 1st set. Still, the vertical movements and inclination changes of all teeth present statistically significant differences between the initially planned and finally achieved movements except for maxillary lateral incisor torque. CONCLUSIONS: The most overbite correction occurs during the 1st set of aligners, and refinement treatment does not significantly improve the deep bite correction.


Assuntos
Má Oclusão Classe II de Angle , Aparelhos Ortodônticos Removíveis , Sobremordida , Humanos , Adulto Jovem , Adulto , Sobremordida/terapia , Estudos Retrospectivos , Técnicas de Movimentação Dentária
16.
Prog Orthod ; 25(1): 10, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38462550

RESUMO

AIM: To evaluate the maxillary incisors and canine's immediate movement tendency using three different power arms (PA) height levels during total arch maxillary distalization supported on infrazygomatic crest (IZC) miniscrews according to finite element analysis (FEA). METHODS: Three finite element models of the maxilla were developed based on CBCT imaging of a teenage male patient presenting a Class II Division 1 malocclusion in the early permanent dentition. Maxillary complex, periodontium, orthodontic accessories, IZC miniscrews and an orthodontic wire were digitally created. The PAs were placed between canines and lateral incisors and projected at 4, 7, and 10 mm height distances. After that, distalization forces were simulated between PA and IZC miniscrews. RESULTS: The anterior teeth deformation produced in the FEA models was assessed according to a Von Mises equivalent. The stress was measured, revealing tendencies of initial maxillary teeth movement. No differences were found between the right and left sides. However, there was a significant difference among models in the under-stress areas, especially the apical and cervical root areas of the maxillary anterior teeth. More significant extrusion and lingual tipping of incisors were observed with the 4 mm power arm compared to the 7 mm and 10 mm ones. The 10 mm power arm did not show any tendency for extrusion of maxillary central incisors but a tendency for buccal tipping and intrusion of lateral incisors. CONCLUSION: The maxillary incisors and canines have different immediate movement tendencies according to the height of the anterior point of the en-masse distalization force application. Based on the PA height increase, a change from lingual to buccal tipping and less extrusion tendency was observed for the incisors, while the lingual tipping and extrusion trend for canines increased.


Assuntos
Má Oclusão Classe II de Angle , Procedimentos de Ancoragem Ortodôntica , Adolescente , Humanos , Masculino , Análise de Elementos Finitos , Técnicas de Movimentação Dentária/métodos , Maxila , Má Oclusão Classe II de Angle/diagnóstico por imagem , Má Oclusão Classe II de Angle/terapia , Fios Ortodônticos , Procedimentos de Ancoragem Ortodôntica/métodos
17.
Clin Oral Investig ; 28(3): 206, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459220

RESUMO

OBJECTIVES: This finite element study aimed to simulate maxillary canine movement during anterior teeth retraction. MATERIALS AND METHODS: Three methods of maxillary canine movement including miniscrew sliding with high hooks (MSH), miniscrew sliding with low hooks (MSL), and the traditional sliding method (TS) without using miniscrews were simulated using three-dimensional finite element analysis. The initial displacement of the maxillary canine, the maximum principal stress of the periodontal ligament and the Von Mises stress were calculated. RESULTS: The distolingual tipping movements of the canine were shown in three movement modes. MSH showed a small tendency to lingual tipping movement and a extrusion movement while MSL had the largest lingual inclination. TS demonstrated a tendency toward distolingual torsion displacement. Compressive stress values were mainly concentrated in the range - 0.003 to -0.006 MPa. For tensile stress, the distribution of MSH and MSL was concentrated in the range 0.005 to 0.009 MPa, TS was mainly distributed about 0.003 MPa. Von Mises equivalent stress distribution showed no significant difference. CONCLUSIONS: The loss of tooth torque was inevitable, irrespective of which method was used to close the extraction space. However, miniscrew application and higher hooks reduced the loss of torque and avoided lingual rotation. CLINICAL RELEVANCE: This study shows that miniscrew implants with different hooks can better control the movement of the maxillary canines. The non-invasive nature of the finite element analysis and its good simulation of dental stress and instantaneous motion trend have a clinical advantage in the analysis of tooth movement.


Assuntos
Dente Canino , Técnicas de Movimentação Dentária , Dente Pré-Molar , Estresse Mecânico , Análise de Elementos Finitos , Torque , Técnicas de Movimentação Dentária/métodos , Maxila
18.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(3): 290-294, 2024 Mar 09.
Artigo em Chinês | MEDLINE | ID: mdl-38432664

RESUMO

Appropriate torque control of anterior teeth is of great significance to obtain ideal orthodontic treatment outcome. Clear aligners are less effective in torque control of anterior teeth due to their special application mode and material properties. Therefore, it is important to investigate how to improve the torque control of anterior teeth by using clear aligners, with the expectation of providing guidance for clinicians. This article discussed the methods to control the torque of anterior teeth by using traditional fixed appliances, the efficiency of clear aligner in controlling the torque of anterior teeth, the difficult points of clear aligner in controlling the torque of anterior teeth and the therapeutic methods to better control the torque of anterior teeth by using clear aligners.


Assuntos
Aparelhos Ortodônticos Removíveis , Técnicas de Movimentação Dentária , Humanos , Torque , Incisivo , Resultado do Tratamento
19.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(3): 295-300, 2024 Mar 09.
Artigo em Chinês | MEDLINE | ID: mdl-38432665

RESUMO

The success of clear aligner treatment relies on rational treatment planning, favorable patients' compliance and high-quality clinical dental monitoring. High-quality clinical dental monitoring involves not only evaluation of real-time tooth position and treatment-designed tooth position, but also the assessment of the root-alveolar bone relationship. However, fluent imaging tests with ionizing radiation are not realistic in clinical practice. Regarding the rapid advances in digital techniques, biomechanism based method, image processing algorithm-based method and multimodal data fusion-based method all exhibit great potential in monitoring tooth movement. This paper introduced the progress and clinical application in those methods for clinicians' reference.


Assuntos
Aparelhos Ortodônticos Removíveis , Técnicas de Movimentação Dentária , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...