Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.599
Filtrar
1.
BMC Oral Health ; 24(1): 355, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38504246

RESUMO

BACKGROUND: In partial edentulous individuals, a partial removable dental prosthesis (PRDP) is a common dental replacement option to improve oral function and quality of life. However, some patients discontinue using their denture over time. The aim of this study was to determine the prevalence and characteristics of partial edentulous patients who no longer wear their dentures, explore their reasons, and assess their oral health-related quality of life (OHRQoL). METHODOLOGY: This cross-sectional study, conducted at Chulalongkorn University Dental School from 2013 to 2019, involved patients who received PRDP treatment. They were contacted via phone calls and asked about their denture usage. Eligible participants were patients who had stopped or rarely used their PRDPs. Data on oral status, health insurance, and PRDP variables were collected from hospital records. Telephone interviews were conducted to collect the initial reasons for seeking PRDP treatment, reasons for discontinuation, desire for a new PRDP, and OHRQoL. The Oral Impacts on Daily Performances index was used to assess the OHRQoL. The score was dichotomized into the absence or presence of oral impacts. Chi-square tests and multivariable binary logistic regression were employed to determine the associations between oral impacts and various factors in the participants who discontinued PRDP usage. RESULTS: Among the 975 contacted participants, 175 (17.9%) discontinued using their PRDPs. Most of these individuals had at least 20 remaining natural teeth and/or 4 posterior occluding pairs. The primary initial reason for seeking PRDP treatment was often based on a dentist's suggestion. Although many participants reported no impact on OHRQoL and did not express the need for new PRDPs, those experiencing oral impacts were more likely to seek replacements. CONCLUSIONS: With up to 7 years follow-up duration, individuals with partial edentulism and sufficient remaining functional dentition without oral impacts were more inclined to discontinue PRDP usage. Those with maxillary anterior teeth loss were less likely to discontinue using their PRDP. The primary initial reason for seeking PRDP treatment was often a dentists' suggestion. However, the individuals reporting oral impacts expressed their needs for new denture replacements. This highlights the significance of incorporating patient needs and preferences in prosthodontic decision-making.


Assuntos
Prótese Dentária , Prótese Parcial Removível , Boca Edêntula , Perda de Dente , Humanos , Qualidade de Vida , Estudos Transversais , Seguimentos , Saúde Bucal
2.
Sci Rep ; 14(1): 5291, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438467

RESUMO

This study aimed to measure marginal and internal fit using images captured with both an optical microscope and a smartphone camera, comparing the fit measurement performance of these devices and analyzing their correlation. Working casts (with 10 posterior and 10 anterior teeth) created to fabricate fixed dental prostheses were used. These working casts were scanned using a desktop scanner (E1) to design an interim crown, and the designed interim crown was fabricated using a three-dimensional (3D) printer. Utilizing the silicone replica technique, the fabricated interim crown replicated the fit, which was then captured using both an optical microscope and a smartphone camera. The captured images were used to measure the marginal and internal fit according to the imaging device. Intraclass correlation coefficients (ICC) were used for reliability analysis according to the imaging device. Furthermore, the Wilcoxon signed-rank test was adopted for the comparative evaluation of the marginal and internal fit between the imaging devices (α = 0.05). The measurement results of the marginal and internal fit according to the optical microscope and smartphone camera did exhibit a significant difference (P < 0.05). The ICC between the two devices showed an "excellent" agreement of over 0.9 at all measurement points (P < 0.001). A smartphone camera could be used to obtain images for evaluating the marginal and internal fit.


Assuntos
Prótese Dentária , Smartphone , Correlação de Dados , Estudos de Viabilidade , Reprodutibilidade dos Testes
3.
Dent Mater J ; 43(2): 235-246, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38417861

RESUMO

Prosthetic biomaterials can affect the composition of the subgingival microbiota and consequently the production of proinflammatory cytokines, causing damage to the periodontium. A total of 40 patients were divided into two groups: 20 with monolithic zirconia (MZ) prostheses and 20 with porcelain fused to metal (PFM) with nickel-chromium (Ni-Cr) alloy prostheses. Subgingival plaque and gingival crevicular fluid samples were taken. The Checkerboard technique for DNA-DNA hybridization and the enzyme-linked immunosorbent assay technique were performed. Teeth with MZ presented a lower percentage of bleeding on probing and tooth mobility compared to teeth with PFM with Ni-Cr alloy. Prosthodontic teeth harbored higher total levels of the 18 bacterial species than non-prosthodontic teeth. There was a higher prevalence of S. gordonii and V. parvula species in PFM with Ni-Cr alloy compared to MZ. There was an increase in IL-1ß, TNF-α and CX3CL1 levels in PFM with Ni-Cr alloy compared to MZ. MZ is a candidate biomaterial with fewer negative effects on the periodontium, allowing for longer prostheses longevity in the mouth.


Assuntos
Prótese Dentária , Microbiota , Humanos , Líquido do Sulco Gengival , Fator de Necrose Tumoral alfa , Ligas de Cromo , Porcelana Dentária , DNA , Quimiocina CX3CL1
4.
J Pak Med Assoc ; 74(2): 247-251, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419221

RESUMO

Objectives: To determine the frequency and extent of artefacts in magnetic resonance imaging and/or computed tomography scans of head caused by fixed dental prosthesis. METHODS: The retrospective study was conducted at Aga Khan University Hospital from July to December 2021, and comprised magnetic resonance imaging and/or computed tomography scans from January 2015 to December 2020 of the head of individuals with existing fixed dental prosthetic work at the time of exposure. They were analysed for the presence of artefacts. The association between artefacts and the presence of fixed dental prosthesis was explored. Data was analysed using SPSS 23. RESULTS: Of the 297 images evaluated, 173 (58%) were magnetic resonance imaging scans, and 124(42%) were computed tomography scans. The most common artefacts was grade I 148(49.8%), followed by grade II 140(47.1%) and grade III 9(3%). There was no significant association between fixed dental prosthesis and the artefacts (p>0.05). Conclusion: There should be no reservations in placing fixed metal prosthesis in individuals on account of future brain scans.


Assuntos
Artefatos , Prótese Dentária , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
5.
Int J Prosthodont ; 37(1): 109, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381993

RESUMO

PURPOSE: To compare the marginal and internal fit of monolithic zirconia (MZ) 3-unit fixed dental prostheses (FDPs) fabricated using two CAD/CAM workflows: full-chairside (FCH) and lab (LAB). MATERIALS AND METHODS: The right maxillary first premolar and first molar were prepared for MZ 3-unit FDPs on a typodont. CEREC Primescan digitized the typodont model 15 Omes. A total of 30 FDPs was fabricated using two processes: FCH (n = 15) and LAB (n = 15). FCH and LAB FDPs were designed using CEREC SW 4.5.1 and Exocad and milled using CEREC MC X and Zirkonzhan 600/V3, respectively. A fast-sintering protocol was used in both groups. A dual-scan technique was used to assess the cement space at the occlusal surface (OC), axial wall (AX), and margin (MA). Statistical analysis of the results was performed using univariate ANOVA with Scheff. post hoc test (a = .05). RESULTS: Measurements in the FCH and LAB groups were within the clinically acceptable marginal and internal fit. The fit of FCH FDPs at MA, AX, and OC was 77.50 ± 29.99 µm, 99.67 ± 21.58 µm, and 150.03 ± 30.78 µm, respectively. The fit of LAB FDPs at MA, AX, and OC was 100.27 ± 27.06 µm, 116.53 ± 17.90 µm, and 142.30 ± 19.00 µm, respectively. The difference between the two groups was not statistically significant. CONCLUSIONS: MZ 3-unit FDPs fabricated using FCH have clinically acceptable marginal and internal fit. This result verifies the ability of FCH workflow to fabricate MZ mulOunit FDPs in a single visit.


Assuntos
Planejamento de Prótese Dentária , Prótese Dentária , Planejamento de Prótese Dentária/métodos , Adaptação Marginal Dentária , Zircônio , Cimentos Dentários , Desenho Assistido por Computador
6.
J Prosthet Dent ; 131(4): 708.e1-708.e8, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383280

RESUMO

STATEMENT OF PROBLEM: Removable dental prostheses require periodic relining with the loss of intaglio surface fit because of mucosal shape changes over time. Therefore, a new material with high adaptability to tissue changes over time would be beneficial. PURPOSE: This study focused on a shape-memory gel (SMG) that softens when heated, retains its shape when cooled, and returns to its original shape when reheated. The purpose was to optimize SMG for intraoral use by controlling the ratio of 2 acrylate monomers and to evaluate the changes in the shape memory and physical properties of SMG with temperature and to evaluate biocompatibility. MATERIAL AND METHODS: SMG specimens were synthesized using the following mixing ratios of 2 monomers, docosyl acrylate (DA) and stearyl acrylate (SA): 0:100, 25:75, 50:50, 75:25, and 100:0. SMG specimens were photopolymerized using a fluorescent light-polymerizing unit. To evaluate shape memory as a function of temperature, permanent deformation was measured based on the standardized compression set test for thermoplastic rubber. For evaluation of the physical properties and cytotoxicity, a 3-dimensionally printed denture base material was used as the control material. All assessments were compared between the groups by using 1-way analysis of variance followed by the Tukey-Kramer multiple comparison test (α=.05). RESULTS: SMGs with a higher amount of DA maintained their compressed shape at room and intraoral temperatures. However, the SMG matrices softened and recovered their original shapes above 60 °C. SMGs showed Shore A hardness equivalent to that of the denture-base polymer material at intraoral temperatures because of the high phase-transition temperature. The low water solubility of SMGs supported the biocompatibility test results. CONCLUSIONS: SMG, in which the phase-transition temperature was controlled by mixing acrylate monomers with different melting points, exhibited shape memory in the intraoral environment. The results indicate the feasibility of applying SMG for the fabrication of removable dental prostheses because of its high adaptability to tissue changes over time and biocompatibility.


Assuntos
Acrilatos , Prótese Dentária , Temperatura , Temperatura de Transição , Teste de Materiais
7.
J Mech Behav Biomed Mater ; 151: 106395, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38244420

RESUMO

OBJECTIVES: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS: The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION: Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).


Assuntos
Implantes Dentários , Prótese Dentária , Zircônio , Suporte de Carga , Parafusos Ósseos , Análise de Variância , Titânio , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Coroas
8.
Int J Legal Med ; 138(2): 685-691, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37347275

RESUMO

Access to better health care anticipates that more medical devices can be found alongside skeletal remains. Those employed in oral rehabilitation, with available brands or batch/series, can prove useful in the identification process. A previous study in the Colecção de Esqueletos Identificados Século XXI described macroscopically the dental prostheses. An unusual case of a dental device with chromatic alterations demonstrated to require a more detailed analysis. The individual, a 53-year-old male, exhibited, at both arches, a fixed tooth-supported rehabilitation, with gold colouring classified initially as a gold-palladium alloy. Simultaneously, a green pigmentation deposit was observable in bone and prosthesis. This investigation aimed to verify the elemental composition of the dental prosthesis alloy. Elemental analysis was performed by X-ray fluorescence in two regions (labial surface of the prosthetic crown and the root surface of the lower right lateral incisor). Both the spectra and the qualitative results found higher levels of copper and aluminium, followed by nickel, iron, zinc, and manganese. No gold or palladium was detected. The most probable assumption is that a copper-aluminium alloy was used, as its elemental concentration corresponds to those measured in similar devices. Dental prostheses of copper-aluminium alloys have been made popular since the 1980s, particularly in the USA, Japan, and Eastern Europe. Apart from the biographical information, it was also known that the individual's place of birth was an Eastern European country, which highlighted the usefulness of this type of information when dealing with missing people cases.


Assuntos
Prótese Dentária , Paládio , Masculino , Humanos , Pessoa de Meia-Idade , Raios X , Portugal , Paládio/análise , Cobre/análise , Alumínio/análise , Fluorescência , Incisivo , Ligas de Ouro/análise
9.
Dent Mater ; 40(2): 198-209, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37951752

RESUMO

OBJECTIVES: To investigate the 5-year intraoral evolution and kinetics of low-temperature degradation (LTD) of second-generation monolithic prostheses made of 3% molar yttrium-doped tetragonal zirconia polycrystal (3Y-TZP) and the influence of masticatory mechanical stresses and glaze layer on this evolution. METHODS: A total of 101 posterior tooth elements were included in this prospective clinical study, which comprised ex vivo LTD monitoring (at baseline, 6 months, 1 year, 2 years, 3 years, and 5 years) using Raman spectroscopy (n = 2640 monoclinic phase measurement points per evaluation time) and scanning electron microscopy (SEM). Four types of areas (1-2 mm2 surface, six on molars, and four on premolars) were analysed on each element surface: occlusal, axial, glazed, or unglazed. Raman mapping, high-resolution SEM, and focused ion beam-SEM were performed on selected samples. RESULTS: The dental prostheses developed a tetragonal-to-monoclinic transformation at the extreme surface of the material after six months in a buccal environment, and this process increased significantly over time. Over the five years of monitoring, the transformation developed nonuniformly with the presence of localised clusters of monoclinic grains. Tribological stresses generate grain pull-out from these clusters, which may raise questions regarding the release of 3Y-TZP nanoparticles into the body. The prosthesis fracture rate was 4.5% after 5 years. SIGNIFICANCE: LTD developed in vivo on the surfaces of 3Y-TZP dental prostheses and progressed slowly but significantly over time, up to 5 years investigation. However, the effects of aging on the failure rate recorded and of zirconia nanoparticles released into the body require further investigation.


Assuntos
Prótese Dentária , Zircônio , Temperatura , Estudos Prospectivos , Propriedades de Superfície , Zircônio/química , Ítrio/química , Teste de Materiais , Materiais Dentários/química , Cerâmica/química
10.
J Prosthet Dent ; 131(2): 330.e1-330.e9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37993321

RESUMO

STATEMENT OF PROBLEM: Prostheses printed on a 3-dimensional (3D) printer need to undergo the postpolymerization process, which can increase the working time. However, it has been not suggested for reducing workload and improving the properties of prostheses in dental clinical practice. PURPOSE: The purpose of this in vitro study was to evaluate how the printing temperature impacts the dimensional accuracy and fracture load of 3D printed fixed dental prostheses (FDPs). MATERIAL AND METHODS: Dental prostheses were printed at room temperature (RT), 50°C, and 70°C using a stereolithography 3D printer. Subsequently, after rinsing away residual monomer, the printed parts underwent the green condition (it was not subjected to any postprocessing) and postpolymerization. The mechanical properties of the printed FDPs were determined by loading to fracture (n=6). To evaluate their clinical applicability, the dimensional accuracy and fit of FDPs fabricated at various resin polymerization temperatures were measured (n=6). The 1-way analysis of variance was used to perform statistical comparisons, followed by the Tukey honestly significant difference test (α=.05). RESULTS: The specimens printed at RT and 50°C were better than those printed at 70°C in terms of dimensional accuracy and fit (P<.05). Nonetheless, the dimensional accuracy and fit of the specimens printed at 70°C were clinically acceptable. The fracture load of the 3-unit FDPs depended significantly on the printing temperature. CONCLUSIONS: The dimensional accuracy and fracture load of the 70°C group were acceptable for FDP fabrication. Thus, the temperature of 70°C without postprocessing may help make the procedure more efficient.


Assuntos
Prótese Dentária , Estereolitografia , Temperatura , Desenho Assistido por Computador , Polimerização , Teste de Materiais , Impressão Tridimensional
11.
Artigo em Inglês | MEDLINE | ID: mdl-37552175

RESUMO

The present study assessed the impact of a fixed prosthetic rehabilitation on masticatory function in patients diagnosed with stage IV periodontitis. Eligible participants were adults in need of complex rehabilitation due to masticatory dysfunction. Masticatory function was evaluated using the two-colored chewing gum mixing ability test (VOH) at the diagnostic phase (T0), 1 week after delivery of the prosthetic prototype (T1), and 1 week after delivery of the final prosthetic solution (T2). Ten subjects were treated with a fixed prosthesis following periodontal and implant surgery using an individualized, fully digital workflow. Full-mouth plaque and bleeding scores, pocket depth, and clinical attachment level improved significantly. VOH was 0.472 ± 0.168 at T0, 0.358 ± 0.166 at T1, and 0.250 ± 0.123 at T2. A significant improvement in VOH was observed from T0 to T1 (difference: -0.114; 95% CI: -0.199 to -0.029; P = .014) and from T1 to T2 (difference: -0.108; 95% CI: -0.200 to -0.015; P = .027). From T0 to T2, VOH increased by 44.3%. Self-perceived assessment of masticatory function also improved from T0 to T2 (P = .002). The fixed prosthetic rehabilitation in patients with stage IV periodontitis allowed for a significant improvement in objective and subjective measurements of masticatory function.


Assuntos
Prótese Dentária , Mastigação , Periodontite , Adulto , Humanos
12.
Odontology ; 112(1): 169-176, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37422770

RESUMO

The aim of this study is to evaluate the effect of pre-ceramic soldering on the marginal and internal fit of 4-unit zirconia fixed dental prostheses (FPDs) that have two abutments and two pontics. 4-unit zirconia frameworks (Zirkonzahn ICE Translucent) (Z Group) and monolithic zirconia (Zirkonzahn Prettau) (M Group) FPDs were manufactured. Groups were divided into two groups (n = 10) control (ZC and MC) and soldering (ZS and MS). Samples of ZS and MS groups were cut into two pieces under cooling water and soldered with a bonding material (DCM Zircon HotBond). The marginal and internal fit of the restorations were measured from 36 points of each sample and cement space volume was calculated using reverse engineering software (Geomagic Design X). The mean and standard deviations were submitted to Generalized Linear Mixed Model (GLMM) analysis (α = 0.05). Statistical differences between groups before and after pre-ceramic soldering on point measurements were found. In total cement spacing measurements, a significant difference was found amongst all groups (P < 0.05). However, in premolars, a statistically significant difference was found between ZC and ZS groups and MC and MS groups (P < 0.05). All discrepancies after pre-ceramic soldering were found to be lower than before.


Assuntos
Porcelana Dentária , Prótese Dentária , Porcelana Dentária/química , Cerâmica/química , Materiais Dentários/química , Zircônio/química , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Adaptação Marginal Dentária , Prótese Parcial Fixa , Desenho Assistido por Computador
13.
J Dent ; 141: 104806, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38154701

RESUMO

OBJECTIVE: This review investigated the current literature pertaining to the repairability of computer-aided design-computer-aided manufacturing (CAD-CAM) milled and three-dimensional (3D) printed resin-based dental prostheses (RBDPs) as well as the appropriate surface treatment for each repair material that will produce adequate repair bond strength. DATA/SOURCES: PubMed, Web of Science, and Scopus databases were searched for published articles involving repair of CAD-CAM RBDPs between January 2010 and June 2023. Data were collected and analyzed to reveal the surface treatment effects, suggested repair materials, and strength of repaired RBDPs. STUDY SELECTION: Out of 164 retrieved titles, 11 studies were included, of which five investigated the repair of 3D-printed RBDPs, three investigated the repair of CAD-CAM milled resins, and three investigated both materials. Additionally, of the included studies, seven investigated denture base resins, three studied provisional restoration resins, and one evaluated 3D-printed intraoral splints. Various surface treatments were suggested, with air-abrasive methods being the most commonly used. Different materials for resin repair were proposed and used, including auto-polymerized, reline, and composite resins. For 3D-printed resins, repair with Bis-acrylic/Bis-GMA composites improved repair strength. CONCLUSION: Surface treatments positively affected the repair strength of conventional and milled RBDPs. However, challenges remain relevant to the repair of 3D-printed resins owing to composition mismatches and fabrication techniques. Therefore, further investigation is required to develop new 3D-printed resins. CLINICAL SIGNIFICANCE: CAD-CAM milled resins have satisfactory repair strength, which increases with surface treatment. The repair of 3D-printed resins has proven challenging even with surface treatments. However, composite resins are the materials of choice.


Assuntos
Resinas Compostas , Prótese Dentária , Teste de Materiais , Desenho Assistido por Computador , Polimetil Metacrilato , Bis-Fenol A-Glicidil Metacrilato , Propriedades de Superfície
14.
Clin Oral Investig ; 28(1): 17, 2023 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-38135856

RESUMO

OBJECTIVES: To investigate the association between access and delivery of complete dental prosthesis according to the proportion of the black population in Brazilian municipalities and to oral health policies. MATERIALS AND METHODS: Ecological data from 2017 to 2021 relating to the delivery of complete dentures stratified by race was collected in all Brazilian cities. We calculated a racial inequality indicator by subtracting the percentage of the black population from the percentage of complete dental prostheses that were delivered to blacks in each municipality. Logistic and linear regression models were carried out. RESULTS: We found that 49.2% (2737) of municipalities delivered complete prostheses. The service was more frequently available in municipalities where black individuals made up 20-80% (odds ratio [OR] = 1.45, 95% confidence interval [CI] 1.15; 1.81), those with dental specialty centers (DSC) (OR = 3.04, 95%CI 2.50; 3.68), and those with more oral health teams (OHTs) (OR = 3.43, 95%CI 2.81; 4.18). Where dental prostheses were available, racial inequities favored the white population by 7.7 percentage points (p < 0.01). Increased inequality was observed in municipalities with more OHTs and/or a higher proportion of black individuals (>80%). CONCLUSIONS: Although municipalities with a DSC, and with more OHTs offer better access to complete dental prosthesis for blacks, racial inequality still impacts the delivery of the service. Primary and secondary healthcare services may even exacerbate this. CLINICAL RELEVANCE: Policymakers should monitor racial inequities in healthcare services. The currently unmet needs of black people are critical, especially in cities with more OHTs and/or increased proportions of black people.


Assuntos
Prótese Dentária , Saúde Bucal , Humanos , Brasil , Modelos Lineares
15.
Int J Prosthodont ; 36(4): 498-500, 2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37699191

RESUMO

PURPOSE: To assess the marginal and internal fit of monolithic zirconia fixed dental prostheses (FDPs) comparing two different intraoral scanners (IOSs) and assessment methods. MATERIALS AND METHODS: A maxillary typodont with three prepared teeth allowed fabrication of five-unit high-translucency monolithic zirconia FDPs. The typodont was scanned with two IOSs: Cerec Omnicam and 3Shape TRIOS 3. In total, 30 FDPs were milled from presintered high-translucency zirconia blocks. Dual-scan and silicone replica assessments were used to determine marginal and internal gaps. RESULTS: A statistical significance was observed for marginal gaps (3Shape [74.27 ± 10.4 µm] and Cerec [86.45 ± 14.3 µm]) and for internal gaps (3Shape [126.12 ± 12.7 µm] and Cerec [112.38 ± 17.2 µm]). CONCLUSIONS: The outcomes of this study showed that the 3Shape TRIOS 3 produced a better overall marginal fit, while the Cerec Omnicam created a better internal fit. Additionally, a greater overall marginal and internal gap was noted with the silicone replica method over the dual-scan method.


Assuntos
Prótese Dentária , Silicones
16.
J Oral Rehabil ; 50(11): 1229-1238, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37394871

RESUMO

BACKGROUND: Tooth loss is associated with reduced protein intake, which leads to sarcopenia and frailty in older adults. OBJECTIVE: To evaluate the protective effect of dental prostheses on decreased protein intake in older adults with tooth loss. METHODS: This cross-sectional study was based on a self-reported questionnaire targeting older adults. Data were obtained from the Iwanuma Survey of the Japan Gerontological Evaluation Study. We used % energy intake (%E) of total protein as the outcome and the use of dental prostheses and number of remaining teeth as explanatory variables. We estimated the controlled direct effects of tooth loss by fixing the use/non-use of dental prostheses based on a causal mediation analysis, including possible confounders. RESULTS: Among 2095 participants, the mean age was 81.1 years (1SD = 5.1), and 43.9% were men. The average protein intake was 17.4%E (1SD = 3.4) of the total energy intake. Among participants with ≥20, 10-19 and 0-9 remaining teeth, the average protein intake was 17.7%E, 17.2%E/17.4%E and 17.0%E/15.4%E (with/without a dental prosthesis), respectively. Compared to participants with ≥20 remaining teeth, those with 10-19 remaining teeth without a dental prosthesis did not have a significantly different total protein intake (p > .05). Among those with 0-9 remaining teeth without a dental prosthesis, total protein intake was significantly low (-2.31%, p < .001); however, the use of dental prostheses mitigated the association by 79.4% (p < .001). CONCLUSION: Our results suggest that prosthodontic treatment could contribute to maintaining protein intake in older adults with severe tooth loss.


Assuntos
Prótese Dentária , Perda de Dente , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Estudos Transversais , Inquéritos e Questionários , Prótese Dentária/efeitos adversos , Japão
17.
BMC Oral Health ; 23(1): 393, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37316922

RESUMO

BACKGROUNDS: Long-span dental bridges may cause excessive load on abutment teeth and the periodontal area, which may lead to bridge fractures or periodontal problems. However, some reports have revealed that short- and long-span bridges can provide a similar prognosis. This clinical study aimed to investigate the technical complications associated with fixed dental prostheses (FDPs) of different span lengths. METHODS: All patients with previously cemented FDPs were clinically examined during their follow-up visits. Several data related to FDPs were registered, such as design, material type, location, and type of complication. The main clinical factors analyzed were technical complications. Life table survival analyses were performed to calculate the cumulative survival rate of FDPs when technical complications were detected. RESULTS: The study examined 229 patients with a total number of 258 prostheses and an average of 98 months of follow-up. Seventy-four prostheses suffered from technical complications, and the most common complication was ceramic fracture or chipping (n = 66), while loss of retention occurred in 11 prostheses. The long-term evaluation of long-span prostheses revealed a significantly higher technical complication rate compared to short-span prostheses (P = ,003). The cumulative survival rate for short-span FDPs was 91% in year 5, 68% in year 10, and 34% in year 15. For long-span FDPs, the cumulative survival rate was 85% in year 5, 50% in year 10, and 18% in year 15. CONCLUSION: Long-span prostheses (5 units or more) can be associated with a higher technical complication rate compared to short-span prostheses after long-term evaluation.


Assuntos
Cemento Dentário , Prótese Dentária , Humanos , Estudos Retrospectivos , Cerâmica
18.
Bratisl Lek Listy ; 124(8): 599-603, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37218492

RESUMO

The work was aimed to determine the level of oral dysbiosis of patients depending on the type of prosthetics constructures. MATERIALS AND METHODS: The study involved 48 patients with the presence in the oral cavity of fixed dentures from 4 to 6 units with a service life of no more than 3 years. The samples of plaque from the vestibular surface of dentures were collected to determine the microorganisms in the gingival plaque. Bacteriological research was carried out by the multiplex polymerase chain reaction in real time using the Phemoflor 8 reagent kit. The degree of dysbiosis of the oral cavity was determined according to the classification of V. Khazanova. RESULTS: The results of the study of patients' samples did not reveal significant changes in the microbial landscape of the cervical areas. The total bacterial mass in the group of healthy individuals was lower than the total bacterial mass of patients in the investigated group significantly. IV degree of oral dysbiosis with a decrease in the number of lactobacilli, streptococci was characteristic of patients of denture wearers. The II degree of dysbiosis in patients with metal-ceramic structures was established. Patients who used solid cast and metal-plastic structures were diagnosed with II-III degree of dysbiosis of the oral cavity. The worst indicators were characteristic of prosthesis wearers of stamped-brazed structures. CONCLUSIONS: Quantitative indicators of the composition of the microbiota of the cervical areas of denture wearers have significant differences and different levels of dysbiosis of the oral cavity, depending on the type of dentures in the patients' mouth (Tab. 2, Fig. 1, Ref. 21). Text in PDF www.elis.sk Keywords.


Assuntos
Prótese Dentária , Disbiose , Humanos , Boca/microbiologia , Bactérias
19.
Medicina (Kaunas) ; 59(5)2023 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-37241173

RESUMO

A dental prosthesis will only be successful if the restoration lasts for a long period and does not cause any illness. The presence of permanent prosthetic restorations has been linked to an increased risk of periodontal infections, according to a large body of research that has been gathered. When chronic inflammation is brought on by fixed prosthetic constructions, both cellular and noncellular immunity are activated as adaptive immune mechanisms. It has previously been stated that both clinically adequate and inadequate restorations might cause gingival inflammation. Areas surrounding the abutment teeth presented periodontal pockets, attachment loss, congestion, bleeding on probing, and gingival hyperplasia after fixed restorations were removed. The depth of pockets, bleeding on probing, and bone loss are all closely correlated with disease's severity and IL-1ß concentration in gingival crevicular fluid; IL-1ß shows higher values in disease sites than in healthy ones. hs-CRP and TNF-α blood levels showed a considerable reduction one day after fixed restorations were applied, in comparison with the pre-treatment values. Collaboration between prosthodontists and periodontists is essential for a good treatment outcome since it will increase the restoration's lifespan, enhance periodontal health, and improve the quality of life for dental patients.


Assuntos
Prótese Dentária , Periodontite , Humanos , Qualidade de Vida , Bolsa Periodontal/metabolismo , Bolsa Periodontal/terapia , Inflamação
20.
Clin Oral Investig ; 27(7): 3809-3816, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37010637

RESUMO

OBJECTIVES: The present study aimed to simulate the influence of palatal extensions for custom-made mouthguards (MGs) on protecting dentoalveolar structures and to provide a theoretical basis for designing a comfortable MG. MATERIALS AND METHODS: Based on finite element analysis (3D-FEA), five groups of maxillary dentoalveolar models of wearing MGs were established: no MG on palatal side (NP), on palatal gingival margin (G0), 2 mm from the palatal gingival margin (G2), 4 mm from the palatal gingival margin (G4), 6 mm from the palatal gingival margin (G6), and 8 mm from the palatal gingival margin (G8). A cuboid was created to simulate the solid ground impacted in falls, a gradually increasing force was applied from 0 to 500 N on the vertical ground, and the distribution and peak values of the Critical modified von-Mises stress, maximum principal stress, and displacement of dentoalveolar models were calculated. RESULTS: Stress distribution range, stress, and deformation peak value of dentoalveolar models increased as the impact strength increased, at 500 N. Maximum critical modified von-Mises stress, peak maximum principal stress and maximum displacement of dentoalveolar models G4, G3, G2, G1, G0, and NP were 154.5 MPa, 154.5 MPa, 154.4 MPa, 154.7 MPa, 154.4 MPa, and 154.7 MPa; 191.65 MPa, 192.11 MPa, 191.62 MPa, 191.81 MPa, 191.56 MPa, and 191.62 MPa; and 88.78 µm, 88.57 µm, 88.19 µm, 88.67 µm, 88.43 µm, and 89.04 µ, respectively. However, the position of the MG palatal edge had little effect on stress distribution, stress, and deformation peak values of the dentoalveolar models. CONCLUSIONS: Different extension ranges of the MG palatal edge have little effect on the protective effects of MGs on maxillary teeth and maxilla. An MG with palatal extension on the gingival margin is more appropriate than other models and may help dentists to design a suitable MG and increase its usage. CLINICAL RELEVANCE: MGs with palatal extensions on the gingival margin may provide a more comfortable wearing experience for individuals involved in sports and encourage increased MG usage.


Assuntos
Prótese Dentária , Dente Impactado , Humanos , Análise de Elementos Finitos , Estresse Mecânico , Análise do Estresse Dentário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...