Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.942
Filtrar
1.
J Int Med Res ; 52(4): 3000605241237680, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606755

RESUMO

Intraventricular haemorrhage (IVH) is a severe and acute type of stroke with a complex pathophysiology and is a therapeutic challenge. This case report described a man in his early 50's diagnosed with IVH by computed tomography (CT). Although bilateral extraventricular drainage (EVD) was undertaken, a postoperative CT scan showed that while the left catheter was correctly positioned, the right catheter had been wrongly inserted into the cisterna ambiens. The procedure was equivalent to simultaneous EVD combined with cisternostomy. As a consequence, the haematoma was rapidly removed, the risk of infection and long-term hydrocephalus was reduced, and prognosis was improved. Large case-control studies or prospective studies are needed to evaluate the safety and effectiveness of this treatment modality.


Assuntos
Hemorragia Cerebral , Hidrocefalia , Masculino , Humanos , Zolpidem/uso terapêutico , Resultado do Tratamento , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/etiologia , Hemorragia Cerebral/cirurgia , Hidrocefalia/cirurgia , Drenagem/métodos , Cateteres/efeitos adversos
2.
Medicine (Baltimore) ; 103(15): e37772, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608117

RESUMO

RATIONALE: Retrograde jejunoduodenogastric intussusception refers to invagination of distal small intestine into the stomach. It is extremely rare. It is often associated with displaced feeding catheter in which its balloon tip migrates past the gastric pylorus. The intussusception is triggered by retraction of migrated catheter. It is often accompanied by feeding intolerance or catheter malfunction. This report describes a distinctive case of retrograde jejunoduodenogastric intussusception associated with a fully functioning nonballoon nasojejunal tube. PATIENT CONCERN: A 19-year-old female was presented with repeated vomiting and abdominal distension for 5 days. DIAGNOSIS: An abdominal computerized tomography revealed retrograde jejunoduodenogastric intussusception causing air/fluid-filled gastric distension. Immediate endoscopic examination revealed a loop of small intestine, protruding through the pylorus. Progressed ischemia of the migrated small bowel loop was confirmed. INTERVENTIONS: At laparotomy, a jejunal loop migrating into the duodenum and stomach at the level of the ligament of Treitz was noticed. After manual reduction of migrated bowel, 2 segmental resections of necrotic segment were performed. A feeding jejunostomy was constructed in the proximal jejunum. OUTCOMES: Enteral feeding through the surgically constructed feeding jejunostomy was started on the 5th operative day and the patient was discharged on the 16th postoperative day. LESSONS: When a patient under tube feeding exhibits abrupt intractable gastroesophageal reflux with a sign of catheter migration, we must consider the possibility of catheter-related intussusception. Having a fully functioning feeding catheter with nonballoon tip does not preclude retrograde jejunoduodenogastric intussusception.


Assuntos
Refluxo Gastroesofágico , Intussuscepção , Feminino , Humanos , Recém-Nascido , Adulto Jovem , Adulto , Intussuscepção/etiologia , Intussuscepção/cirurgia , Cateteres/efeitos adversos , Estômago , Vômito
3.
Urolithiasis ; 52(1): 59, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568426

RESUMO

To evaluate the safety and efficacy of tubeless percutaneous nephrolithotomy (PCNL) in patients with Escherichia coli (E. coli) bacteriuria. We conducted a retrospective review of 84 patients with E. coli bacteriuria who underwent PCNL. Patients were divided into two groups according to whether a nephrostomy tube is placed at the end of the procedure. Preoperative clinical data, surgical outcomes, and postoperative complications were compared. Then, regression analysis of factors predicting success rate of PCNL in patients with E. coli bacteriuria was performed. After PCNL, residual fragments ≤ 4 mm were considered as success. At baseline, the two groups were similar with regard to age, gender, BMI, underlying disease, hydronephrosis, stone characteristics, and urinalysis. Postoperative fever occurred in 1 patient (3.8%) in the tubeless PCNL group, and in 5 patients (8.6%) in the conventional PCNL group (p > 0.05). There were no significant differences in terms of successful rate, decrease in hemoglobin, pain scores, blood transfusion, and hospitalization expenses. However, the tubeless PCNL group had significantly shorter operative time (60 vs. 70 min, p = 0.033), indwelling time of catheter (2 vs. 4 days, p < 0.001), and hospital stays (3 vs. 5 days, p < 0.001) than the conventional PCNL group. In the analysis of factors predicting success, the stone diameter, stone burden, and operative time were associated with success rate of PCNL. It is safe and effective to perform tubeless PCNL in patients with E. coli bacteriuria. Compared to conventional PCNL, tubeless PCNL accelerates patient recovery and shortens hospital stays.


Assuntos
Bacteriúria , Nefrolitotomia Percutânea , Humanos , Nefrolitotomia Percutânea/efeitos adversos , Escherichia coli , Cateteres , Hospitalização
4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584395

RESUMO

AIMS: A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS: A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION: The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fenômenos Magnéticos , Recidiva
5.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Cateteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
6.
Adv Tech Stand Neurosurg ; 50: 1-30, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38592526

RESUMO

As a concept, drainage of excess fluid volume in the cranium has been around for more than 1000 years. Starting with the original decompression-trepanation of Abulcasis to modern programmable shunt systems, to other nonshunt-based treatments such as endoscopic third ventriculostomy and choroid plexus cauterization, we have come far as a field. However, there are still fundamental limitations that shunts have yet to overcome: namely posture-induced over- and underdrainage, the continual need for valve opening pressure especially in pediatric cases, and the failure to reinstall physiologic intracranial pressure dynamics. However, there are groups worldwide, in the clinic, in industry, and in academia, that are trying to ameliorate the current state of the technology within hydrocephalus treatment. This chapter aims to provide a historical overview of hydrocephalus, current challenges in shunt design, what members of the community have done and continue to do to address these challenges, and finally, a definition of the "perfect" shunt is provided and how the authors are working toward it.


Assuntos
Hidrocefalia , Próteses e Implantes , Humanos , Criança , Instituições de Assistência Ambulatorial , Terapia Comportamental , Cateteres , Hidrocefalia/cirurgia
7.
A A Pract ; 18(4): e01774, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38587301

RESUMO

Traditionally, intrathecal therapy has been used for pain amelioration in cancer patients, but now has indications for nonmalignant chronic pain conditions. Due to its expanding use, it is imperative to understand the risks and management of intrathecal pump implantation. This case illustrates a series of uncommon intrathecal pump complications in a 52-year-old woman with complex regional pain syndrome. Considering the complications outlined in this case, there is a need to conduct retrospective studies and establish guidelines to address when it is optimal to remove a chronically placed catheter as well as the proper technique for removal.


Assuntos
Dor Crônica , Síndromes da Dor Regional Complexa , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Bombas de Infusão Implantáveis/efeitos adversos , Dor Crônica/tratamento farmacológico , Cateteres
8.
A A Pract ; 18(4): e01777, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38587314

RESUMO

Tethered cord syndrome results from adherence of the conus medullaris to the sacrum and may be associated with high complication rates from neuraxial anesthesia. We present the case of a 32-year-old gravida 2 para 0 patient with a history of lipomyelomeningocele (one of several types of spina bifida) and tethered cord status post repair, residual low-lying conus medullaris, supermorbid obesity (body mass index of 58), and Mallampati IV airway, who underwent successful fluoroscopically guided epidural catheter placement for vaginal delivery. Risks and benefits of epidural catheter utilization and methods of placement are reviewed.


Assuntos
Anestesia Epidural , Defeitos do Tubo Neural , Obesidade Mórbida , Feminino , Humanos , Adulto , Obesidade Mórbida/complicações , Medula Espinal , Cateteres
9.
J Vis Exp ; (205)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38587368

RESUMO

Acute myocardial infarction (AMI) is a prevalent and high-mortality cardiovascular condition. Despite advancements in revascularization strategies for AMI, it frequently leads to myocardial ischemia-reperfusion injury (IRI), amplifying cardiac damage. Murine models serve as vital tools for investigating both acute injury and chronic myocardial remodeling in vivo. This study presents a unique closed-chest technique for remotely inducing myocardial IRI in mice, enabling the investigation of the very early phase of occlusion and reperfusion using in-vivo imaging such as MRI or PET. The protocol utilizes a remote occlusion method, allowing precise control over ischemia initiation after chest closure. It reduces surgical trauma, enables spontaneous breathing, and enhances experimental consistency. What sets this technique apart is its potential for simultaneous noninvasive imaging, including ultrasound and magnetic resonance imaging (MRI), during occlusion and reperfusion events. It offers a unique opportunity to analyze tissue responses in almost real-time, providing critical insights into processes during ischemia and reperfusion. Extensive systematic testing of this innovative approach was conducted, measuring cardiac necrosis markers for infarction, assessing the area at risk using contrast-enhanced MRI, and staining infarcts at the scar maturation stage. Through these investigations, emphasis was placed on the value of the proposed tool in advancing research approaches to myocardial ischemia-reperfusion injury and accelerating the development of targeted interventions. Preliminary findings demonstrating the feasibility of combining the proposed innovative experimental protocol with noninvasive imaging techniques are presented herein. These initial results highlight the benefit of utilizing the purpose-built animal cradle to remotely induce myocardial ischemia while simultaneously conducting MRI scans.


Assuntos
Infarto do Miocárdio , Isquemia Miocárdica , Traumatismo por Reperfusão Miocárdica , Camundongos , Animais , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Necrose , Cateteres , Modelos Animais de Doenças
10.
J Vis Exp ; (205)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38587399

RESUMO

Catheter-related infection (CRI) is a common nosocomial infection caused by candida albicans during catheter implantation. Typically, biofilms are formed on the outer surface of the catheter and lead to disseminated infections, which are fatal to patients. There are no effective prevention and treatment management in clinics. Therefore, it is urgent to establish an animal model of CRI for the preclinical screening of new strategies for its prevention and treatment. In this study, a polyethylene catheter, a widely used medical catheter, was inserted into the back of the BALB/c mice after hair removal. Candida albicans ATCC MYA-2876 (SC5314) expressing enhanced green fluorescent protein was subsequently inoculated on the skin's surface along the catheter. Intense fluorescence was observed on the surface of the catheter under a fluorescent microscope 3 days later. Mature and thick biofilms were found on the surface of the catheter via scanning electron microscopy. These results indicated the adhesion, colonization, and biofilm formation of candida albicans on the surface of the catheter. The hyperplasia of the epidermis and the infiltration of inflammatory cells in the skin specimens indicated the histopathological changes of the CRI-associated skin. To sum up, a mouse CRI model was successfully established. This model is expected to be helpful in the research and development of therapeutic management for candida albicans associated CRI.


Assuntos
Candida albicans , Infecções Relacionadas a Cateter , Humanos , Camundongos , Animais , Cateteres , Modelos Animais de Doenças , Biofilmes , Antifúngicos
13.
Biosens Bioelectron ; 255: 116267, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38581838

RESUMO

External ventricular drainage is one of the most common neurosurgical procedures in the world for acute hydrocephalus, which must be performed carefully by a neurosurgeon. Although various neuromonitoring external ventricular drain (EVD) catheters have been utilized, they still suffer from rigidity and bulkiness to mitigate post-EVD placement trauma. Here, we introduce a flexible and low-profile smart EVD catheter using a class of technologies with sensitive electrical materials, seamless integration, and flexible mechanics, which serves as a highly soft and minimally invasive device to monitor electrical brain signals. This device reliably captures biopotentials in real time while exhibiting remarkable flexibility and reliability. The seamless integration of its sensory system promises a minimally invasive EVD placement on brain tissue. This work validates the device's distinct characteristics and performances through in vitro experiments and computational analysis. Collectively, this device's exceptional patient- and user-friendly attributes highlight its potential as one of the most practical EVD catheters.


Assuntos
Técnicas Biossensoriais , Humanos , Reprodutibilidade dos Testes , Cateteres , Encéfalo , Drenagem/métodos
14.
J Diabetes ; 16(4): e13536, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38599884

RESUMO

AIMS: It is not clear whether there are differences in glycemic control between the Equil patch and the MMT-712 insulin pump. Our objective was to compare two types of insulin pumps in the treatment of type 2 diabetes mellitus (T2DM), using continuous glucose monitoring (CGM) metrics and profiles. METHODS: This was a randomized case-crossover clinical trial. Participants were hospitalized and randomly allocated to two groups and underwent two types of insulin pump treatments (group A: Equil patch-Medtronic MMT-712 insulin pump; group B: Medtronic MMT-712-Equil patch insulin pump) separated by a 1-day washout period. Glycemic control was achieved after 7-8 days of insulin pump therapy. Each patient received CGM for 5 consecutive days (from day 1 to day 5). On day 3 of CGM performance, the Equil patch insulin pump treatment was switched to Medtronic MMT-712 insulin pump treatment at the same basal and bolus insulin doses or vice versa. CGM metrics and profiles including glycemic variability (GV), time in range (TIR, 3.9-10.0 mmol/L), time below range (TBR, <3.9 mmol/L), time above range (TAR, >10.0 mmol/L), and postprandial glucose excursions, as well as incidence of hypoglycemia. RESULTS: Forty-six T2DM patients completed the study. There was no significant difference in parameters of daily GV and postprandial glucose excursions between the Equil patch insulin pump treatment and the Medtronic insulin pump treatment. Similarly, there was no between-treatment difference in TIR, TBR, and TAR, as well as the incidence of hypoglycemia. CONCLUSION: The Equil patch insulin pump was similar to the traditional MMT-712 insulin pump in terms of glycemic control. Equil patch insulin pump is a reliable tool for glycemic management of diabetes mellitus.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Humanos , Glicemia , Automonitorização da Glicemia , Cateteres , 60431 , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glucose , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Estudos Cross-Over
15.
Eur Rev Med Pharmacol Sci ; 28(7): 2654-2661, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38639504

RESUMO

OBJECTIVE: This study aimed to explore the effect of flipped venous catheters combined with spinal cord electrical stimulation on functional recovery in patients with sciatic nerve injury. PATIENTS AND METHODS: 160 patients with hip dislocation and sciatic nerve injury were divided into conventional release and flipped catheter + electrical stimulation groups according to the treatment methods (n=80). Motor nerve conduction velocity (MCV) and lower limb motor function were compared. Serum neurotrophic factors brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) were compared. The frequency of complications and quality of life were also compared. RESULTS: The MCV levels of the common peroneal nerve and tibial nerve in the flipped catheter + electrical stimulation group were greater than the conventional lysis group (p<0.05). After treatment, the lower extremity motor score (LMEs) in the flipped catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). The serum levels of BDNF and NGF in the flip catheter + electrical stimulation group were higher than the conventional lysis group (p<0.05). The complication rate in the flipped catheter + electrical stimulation group was lower than in the conventional release group (6.25% vs. 16.25%, p<0.05). The quality-of-life score in the flip catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). CONCLUSIONS: The flipped venous catheter combined with spinal cord electrical stimulation can improve nerve conduction velocity, lower limb motor function, serum BDNF and NGF levels, reduce complications, and help improve the quality of life of sufferers with sciatic nerve injury. Chictr.org.cn ID: ChiCTR2400080984.


Assuntos
Fator Neurotrófico Derivado do Encéfalo , Neuropatia Ciática , Ratos , Animais , Humanos , Fator Neurotrófico Derivado do Encéfalo/metabolismo , Ratos Sprague-Dawley , Fator de Crescimento Neural/metabolismo , Qualidade de Vida , Neuropatia Ciática/metabolismo , Neuropatia Ciática/terapia , Medula Espinal/metabolismo , Nervo Isquiático , Cateteres , Estimulação Elétrica/métodos
16.
Medicine (Baltimore) ; 103(16): e37849, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640270

RESUMO

INTRODUCTION: Left-sided inferior vena cava (IVC) is an uncommon condition with a prevalence rate of 0.2% to 0.5%. Most of them remain asymptomatic and are discovered incidentally. The patient condition in this case is critical, and conventional procedures are not applicable. The surgical approach being considered is innovative, but it carries significant risks and uncertain therapeutic efficacy. PATIENT CONCERNS: A 42-year-old male presented with acute right lower extremity pain with swelling for 2 days. DIAGNOSIS: The patient was subsequently diagnosed with acute right lower extremity deep vein thrombosis, inferior vena cava thrombosis, and a left-sided IVC. INTERVENTIONS: Based on the treatment guidelines for lower extremity deep venous thrombosis. OUTCOMES: We successfully cured him with percutaneous mechanic thrombectomy (PMT) combined with catheter directed thrombolysis (CDT). CONCLUSION AND SIGNIFICANCE: The relatively low incidence of left-sided IVC does not diminish the significance of its identification. PMT combined with CDT is a safe way to treat acute thrombosis. It provides a new approach for similar patients in the future.


Assuntos
Terapia Trombolítica , Trombose Venosa , Humanos , Masculino , Adulto , Terapia Trombolítica/métodos , Fibrinolíticos/uso terapêutico , Veia Cava Inferior , Extremidade Inferior/irrigação sanguínea , Trombose Venosa/tratamento farmacológico , Trombectomia/métodos , Cateteres , Resultado do Tratamento
17.
Int Wound J ; 21(4): e14795, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572781

RESUMO

This study investigates the effects of comprehensive nursing interventions on wound pain in patients undergoing catheter insertion for peritoneal dialysis. Sixty patients who underwent catheter insertion for peritoneal dialysis from January 2021 to January 2023 at our hospital were selected as subjects and randomly divided into an experimental group and a control group using a random number table method. The control group received routine nursing care, while the experimental group was subjected to comprehensive nursing interventions. The study compared the impact of nursing measures on visual analogue scale (VAS), self-rating anxiety scale (SAS), self-rating depression scale (SDS) and nursing satisfaction between the two groups. The analysis revealed that on the third, fifth and seventh days post-intervention, the experimental group's wound VAS scores were significantly lower than those of the control group (p < 0.001). Furthermore, levels of anxiety and depression were markedly lower in the experimental group compared with the control group (p < 0.001). In addition, the nursing satisfaction rate was significantly higher in the experimental group than in the control group (96.67% vs. 73.33%, p = 0.011). This study indicates that the application of comprehensive nursing interventions in patients undergoing catheter insertion for peritoneal dialysis is highly effective. It can alleviate wound pain and negative emotions to a certain extent, while also achieving high patient satisfaction, thus demonstrating significant clinical value.


Assuntos
Dor , Diálise Peritoneal , Humanos , Ansiedade/etiologia , Ansiedade/terapia , Transtornos de Ansiedade , Cateteres
18.
Antimicrob Resist Infect Control ; 13(1): 38, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600526

RESUMO

BACKGROUND: Most surveillance systems for catheter-related bloodstream infections (CRBSI) and central line-associated bloodstream infections (CLABSI) are based on manual chart review. Our objective was to validate a fully automated algorithm for CRBSI and CLABSI surveillance in intensive care units (ICU). METHODS: We developed a fully automated algorithm to detect CRBSI, CLABSI and ICU-onset bloodstream infections (ICU-BSI) in patients admitted to the ICU of a tertiary care hospital in Switzerland. The parameters included in the algorithm were based on a recently performed systematic review. Structured data on demographics, administrative data, central vascular catheter and microbiological results (blood cultures and other clinical cultures) obtained from the hospital's data warehouse were processed by the algorithm. Validation for CRBSI was performed by comparing results with prospective manual BSI surveillance data over a 6-year period. CLABSI were retrospectively assessed over a 2-year period. RESULTS: From January 2016 to December 2021, 854 positive blood cultures were identified in 346 ICU patients. The median age was 61.7 years [IQR 50-70]; 205 (24%) positive samples were collected from female patients. The algorithm detected 5 CRBSI, 109 CLABSI and 280 ICU-BSI. The overall CRBSI and CLABSI incidence rates determined by automated surveillance for the period 2016 to 2021 were 0.18/1000 catheter-days (95% CI 0.06-0.41) and 3.86/1000 catheter days (95% CI: 3.17-4.65). The sensitivity, specificity, positive predictive and negative predictive values of the algorithm for CRBSI, were 83% (95% CI 43.7-96.9), 100% (95% CI 99.5-100), 100% (95% CI 56.5-100), and 99.9% (95% CI 99.2-100), respectively. One CRBSI was misclassified as an ICU-BSI by the algorithm because the same bacterium was identified in the blood culture and in a lower respiratory tract specimen. Manual review of CLABSI from January 2020 to December 2021 (n = 51) did not identify any errors in the algorithm. CONCLUSIONS: A fully automated algorithm for CRBSI and CLABSI detection in critically-ill patients using only structured data provided valid results. The next step will be to assess the feasibility and external validity of implementing it in several hospitals with different electronic health record systems.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Infecção Hospitalar , Sepse , Humanos , Feminino , Pessoa de Meia-Idade , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Estudos Prospectivos , Estudos Retrospectivos , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Cateteres , Algoritmos
19.
J Clin Apher ; 39(3): e22111, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38634439

RESUMO

The objective of this study was to assess the use of midline catheters as venous access for apheresis procedures in pediatric patients. A retrospective analysis of medical records was conducted from September 2019 to June 2022 to evaluate the safety and efficacy of midline catheters for therapeutic pediatric apheresis. During the study period, a total of 121 procedures were inserted in 22 unique patients. The age of the subjects ranged from 2.7 to 21 years. The blood flow rates achieved with midline catheters met or exceeded the recommended rates for apheresis in children (40 mL/min), by the Wilcoxon signed-rank test (p < 0.0001). There was one episode of catheter-related thrombosis, but no cases of bloodstream infection or catheter dislodgement were reported. In conclusion, this study supports the use of midline catheters as a safe and effective alternative for venous access during therapeutic and donor apheresis procedures in pediatric patients.


Assuntos
Remoção de Componentes Sanguíneos , Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Trombose , Humanos , Criança , Pré-Escolar , Adolescente , Adulto Jovem , Adulto , Cateterismo Venoso Central/métodos , Estudos Retrospectivos , Cateteres , Remoção de Componentes Sanguíneos/métodos , Cateterismo Periférico/métodos
20.
Sci Rep ; 14(1): 9111, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643229

RESUMO

Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) may be useful in treating exsanguinating trauma patients. This study seeks to compare rates of success, complications and time required for vascular access between ultrasound-guidance and surgical cut-down for femoral sheath insertion as a prospective observational case control study. Participating clinicians from either trauma surgery or anesthesiology were allocated to surgical cut-down or percutaneous ultrasound-guided puncture on a 1:1 ratio. Time spans to vessel identification, successful puncture, and balloon inflation were recorded. 80 study participants were recruited and allocated to 40 open cut-down approaches and 40 percutaneous ultrasound-guided approaches. REBOA catheter placement was successful in 18/40 cases (45%) using a percutaneous ultrasound guided technique and 33/40 times (83%) using the open cut-down approach (p < 0.001). Median times [in seconds] compared between percutaneous ultrasound-guided puncture and surgical cut-down were 36 (18-73) versus 117(56-213) for vessel visualization (p < 0.001), 136 (97-175) versus 183 (156-219) for vessel puncture (p < 0.001), and 375 (240-600) versus 288 (244-379) for balloon inflation (p = 0.08) overall. Access to femoral vessels for REBOA catheter placement is safer when performed by cut-down and direct visualization but can be performed faster by an ultrasound-guided technique when vessels can be identified clearly and rapidly.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Choque Hemorrágico , Humanos , Estudos de Casos e Controles , Procedimentos Endovasculares/métodos , Hemorragia/etiologia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Ressuscitação/métodos , Oclusão com Balão/métodos , Cateteres/efeitos adversos , Ultrassonografia de Intervenção/efeitos adversos , Choque Hemorrágico/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...