Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31.719
Filtrar
1.
Sci Rep ; 14(1): 8723, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622273

RESUMO

The Alpha stent is an intracranial closed-cell stent with a unique mesh design to enhance wall apposition. It recently underwent structural modifications to facilitate easier stent deployment. This study aimed to evaluate the safety and efficacy of stent-assisted coil embolization for unruptured intracranial aneurysms using the Alpha stent. Between January 2021 and November 2021, 35 adult patients with 35 unruptured intracranial aneurysms in the distal internal carotid artery were prospectively enrolled. For efficacy outcomes, magnetic resonance angiography at the 6-month follow-up was evaluated using the Raymond-Roy occlusion classification (RROC). The safety outcome evaluated the occurrence of symptomatic procedure-related neurological complications up to 6 months postoperatively. Technical success was achieved in 34/35 (97.1%). Six months postoperatively, aneurysm occlusion showed RROC I in 32/35 (91.4%) and RROC II in 3/35 (8.6%) patients. Procedure-related neurologic complications occurred in one patient (2.9%) who experienced hemiparesis due to acute lacunar infarction, which resulted in a 6-month mRS score of 1. The Alpha stent demonstrated excellent efficacy and safety outcomes in stent-assisted coil embolization of unruptured distal ICA aneurysms. The recent structural modifications allowed for easier stent delivery and deployment.Clinical trial registration number: KCT0005841; registration date: 28/01/2021.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Adulto , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Stents/efeitos adversos , Prótese Vascular , Angiografia Cerebral/métodos , Estudos Retrospectivos
2.
J Cardiothorac Surg ; 19(1): 239, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632653

RESUMO

OBJECTIVES: Aortic pathologies often present with elevated inflammatory biomarkers due to the nature of the disease. Open aortic surgery causes significant trauma to the body due to often mandatory ischemic periods, long cardiopulmonary bypass times and polytransfusion. We aim to determine postoperative trends on inflammation biomarkers for different aortic pathologies and type of surgery in different segments of the aorta. METHODS: Retrospective review of prospectively collected data of 193 consecutive patients who underwent aortic surgery in our centre between 2017 and 2021, grouped according to the type of aortic intervention: (1) Type A aortic dissection (AD) repair with ascending aorta/hemiarch replacement, (2) Aortic root replacement (ARR), (3) Aortic arch + Frozen elephant trunk (FET), (4) Descending thoracic aorta (DTA)/Thoraco-Abdominal aortic repair (TAA). Primary outcomes were daily values of white blood cells (WBC) and C-Reactive Protein (CRP) during the first 15 postoperative days. RESULTS: All groups had a similar inflammatory peak in the first 2-4 days (WBC 12-15 × 109 c/L). AD and FET groups show similar trends with WBC and CRP peaks on days 2 and 10. The ARR group didn't experience the 2nd peak as most patients were already discharged. DTA/TAA patients experienced a more prolonged inflammatory response, reaching a plateau by day 5-10. AD group shows the highest WBC levels and the DTA/TAAA group the highest CRP levels. CRP levels remain elevated (100-200 mg/L) in all groups after 15 postoperative days. CONCLUSIONS: Inflammatory biomarkers show different postoperative trends depending on the clinical presentation and complexity of the aortic procedure performed. Further understanding of the inflammatory response to different aortic pathologies and surgical procedures will permit reduction on the liberal use of antibiotics that this cohort of patients are usually exposed to. An earlier version of the data included in this manuscript was presented as Oral Abstract in the UK Society of Cardiothoracic Surgery Annual meeting in 2021.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Humanos , Implante de Prótese Vascular/métodos , Aorta/cirurgia , Aorta Torácica/cirurgia , Estudos Retrospectivos , Inflamação , Biomarcadores , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Prótese Vascular
3.
J Mech Behav Biomed Mater ; 154: 106531, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38588633

RESUMO

Despite polyester vascular grafts being routinely used in life-saving aortic aneurysm surgeries, they are less compliant than the healthy, native human aorta. This mismatch in mechanical behaviour has been associated with disruption of haemodynamics contributing to several long-term cardiovascular complications. Moreover, current fabrication approaches mean that opportunities to personalise grafts to the individual anatomical features are limited. Various modifications to graft design have been investigated to overcome such limitations; yet optimal graft functionality remains to be achieved. This study reports on the development and characterisation of an alternative vascular graft material. An alginate:PEGDA (AL:PE) interpenetrating polymer network (IPN) hydrogel has been produced with uniaxial tensile tests revealing similar strength and stiffness (0.39 ± 0.05 MPa and 1.61 ± 0.19 MPa, respectively) to the human aorta. Moreover, AL:PE tubular conduits of similar geometrical dimensions to segments of the aorta were produced, either via conventional moulding methods or stereolithography (SLA) 3D-printing. While both fabrication methods successfully demonstrated AL:PE hydrogel production, SLA 3D-printing was more easily adaptable to the fabrication of complex structures without the need of specific moulds or further post-processing. Additionally, most 3D-printed AL:PE hydrogel tubular conduits sustained, without failure, compression up to 50% their outer diameter and returned to their original shape upon load removal, thereby exhibiting promising behaviour that could withstand pulsatile pressure in vivo. Overall, these results suggest that this AL:PE IPN hydrogel formulation in combination with 3D-printing, has great potential for accelerating progress towards personalised and mechanically-matched aortic grafts.


Assuntos
Aneurisma Aórtico , Impressão Tridimensional , Humanos , Prótese Vascular , Aorta , Hidrogéis
4.
J Cardiothorac Surg ; 19(1): 237, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627730

RESUMO

Redo ascending and aortic arch surgeries following previous cardiac or aortic surgery are associated with high risk of morbidity and mortality due to multiple factors included sternal re-entry injury, extensive aortic arch surgery, emergency aortic surgery, prolonged cardiopulmonary bypass duration, poor heart function, and patients with older age. Therefore, appropriate surgical strategies are important. We report a case of a 72-year-old gentleman with previous surgery of aortic root replacement who presented with acute Type A aortic dissecting aneurysm of ascending and aortic arch complicated with left hemothorax, which was successfully treated by emergency redo aortic surgery with frozen elephant trunk (FET) technique.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Masculino , Humanos , Idoso , Aorta Torácica/cirurgia , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Valva Aórtica/cirurgia , Dissecção Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Stents
5.
J Cardiothorac Surg ; 19(1): 199, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600502

RESUMO

BACKGROUND: Total endovascular technique with fenestrated endovascular graft might be hampered for the late dilatation of proximal landing zone, which may cause endografts migration. We describe a successful urgent hybrid procedure for extent III thoracoabdominal aortic aneurysm with aortic intramural hematoma. CASE PRESENTATION: A 55-year-old female with thoracoabdominal aortic aneurysm was considered at high surgical risk and unfit for open repair due to multiple comorbidities. Therefore, a hybrid procedure of surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted Transaortic epicardial fixation of endograft was finally chosen and performed in the endovascular operating room. A 3-port technique was performed through a left video-assisted thoracoscopic approach. After the first tampering stent-graft was deployed, a double-needle suture was penetrated both the aortic wall and stent-graft to fixate it in the proximal descending aorta. Then the second endograft, which had been fenestrated on table, was introduced and oriented extracorporeally by rotating superior mesenteric artery and left renal artery fenestration radiopaque markers and deployed with perfect apposition between the fenestrations and target visceral artery. Each vessel was sequentially stented using Viabahn self-expandable stent to finish target vessel stenting. An Ankura cuff stent was deployed in the distal abdominal aortic artery. CONCLUSION: Surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted fixation may be an innovative and viable alternative for selected high-risk patients with extent III thoracoabdominal aortic aneurysm. A longer follow-up is needed to ascertain the success of this approach.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Cirurgiões , Feminino , Humanos , Pessoa de Meia-Idade , Prótese Vascular , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Toracoscópios , Resultado do Tratamento , Stents , Procedimentos Endovasculares/métodos , Desenho de Prótese , Aneurisma da Aorta Abdominal/cirurgia
6.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579061

RESUMO

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Masculino , Humanos , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Axila/cirurgia , Perna (Membro)/cirurgia , Procedimentos Endovasculares/métodos , Stents , Resultado do Tratamento , Aneurisma Ilíaco/cirurgia
7.
Expert Rev Med Devices ; 21(3): 165-177, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38431273

RESUMO

INTRODUCTION: With the incidence of thoracic aortic disease on the rise, total arch replacement (TAR) with frozen elephant trunk (FET) remains the gold-standard management strategy due to optimal results. Several FET devices exist commercially on the global market. However, the mainstay and most commonly used and reported device is the Thoraflex Hybrid Prosthesis (THP), with several recent reports suggesting its superiority. AREAS COVERED: This review aims to collate and summarize the evidence in the literature on the clinical outcomes of TAR with FET using THP, with a focus on mortality, neurological complications, endoleak, distal stent-induced new entry (dSINE), aortic remodeling, coagulopathy, and graft kinking. In addition, the design features of THP is discussed, and an overview of market competitors is also highlighted. EXPERT OPINION: THP consistently demonstrates its effectiveness in treating complex thoracic aortic pathology through favorable clinical outcomes, which can be attributed to its unique and innovative design. Rates of early mortality ranged 0.6-14.2%, neurological complications 0-25%, endoleak 0-8.4% and dSINE 0-14.5%, with minimal incidence of graft kinking and coagulopathy. Aortic remodeling is favorable and comparable to competitors. All this evidence solidifies THP as the leading FET device, particularly when combined with appropriate patient selection and surgical planning.


Assuntos
Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Prótese Vascular , Endoleak/cirurgia , Stents , Aorta Torácica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
8.
Medicine (Baltimore) ; 103(10): e37410, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38457563

RESUMO

RATIONALE: Acute type B aortic dissection (ABAD) is a fatal cardiovascular disease with high morbidity and mortality. Isolated left vertebral artery (ILVA) is a rare aortic arch mutation originating from the aortic arch. The simultaneous occurrence of both increases the complexity and difficulty of thoracic endovascular aortic repair. However, there have been few reports on the recommendation of thoracic endovascular aortic repair treatment strategies for aortic dissection patients concomitant ILVA with insufficient landing zone. Here, we report a case of ABAD combined with ILVA treated with hybrid surgery of left vertebral artery transposition alliance with Scallop and in vivo fenestration endograft. PATIENT CONCERNS: A 38-year-old middle-aged man was transferred to our vascular department with persistent pain in his lower abdomen for 8 hours. DIAGNOSES: Preoperative computed tomography angiogram of the thoracic and abdominal aorta diagnosed with ABAD accompanied with ILVA. INTERVENTIONS: Hybrid surgery of left vertebral artery transposition alliance with Scallop and in situ fenestration endograft for revascularization of ILVA, left subclavian artery, and left common carotid artery. OUTCOMES: The hybridization operation was successfully completed. There were no complications of cerebral and spinal cord ischemia after operation. Computed tomography angiogram examination indicated no internal leakage existed in the stent and patency of the arch vessels and the transposed left vertebral artery follow-up 3 months after surgery. LESSONS: This study gave us experience in the treatment of aortic dissection with left vertebral artery variation and suggested that left vertebral artery transposition combined with scallop and in vivo fenestration stent is safe and effective.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Pectinidae , Masculino , Pessoa de Meia-Idade , Humanos , Adulto , Animais , Aorta Torácica/cirurgia , Artéria Vertebral/diagnóstico por imagem , Artéria Vertebral/cirurgia , Prótese Vascular , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Dissecção Aórtica/complicações , Dissecção Aórtica/cirurgia , Artéria Subclávia , Stents/efeitos adversos , Implante de Prótese Vascular/métodos
9.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38485695

RESUMO

Endovascular aortic arch repair (Ar-TEVAR) with single-branch, off-the-shelf Nexus aortic arch system has shown promising early and 3-year outcomes. There is lack of data regarding long-term results of this specific device, particularly regarding patency of supra-aortic bypasses and stability of the connection between the 2 modules. This case report describes 6-year clinical and imaging follow-up of a 74-year-old patient who underwent Ar-TEVAR with Nexus. Over 6 years, the patient experienced minor complications unrelated to the device. The patency of supra-aortic bypasses and integrity of the device's connection were confirmed. Computed tomography angiography constantly showed exclusion of the aneurysm and reduction of the aneurysmal sac. In conclusion, although extended research and broader data are needed, this case provides encouraging evidence of long-term results of Ar-TEVAR with Nexus.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Idoso , Prótese Vascular , Angiografia por Tomografia Computadorizada , Implante de Prótese Vascular/métodos , Stents , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Seguimentos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Estudos Retrospectivos
10.
Nat Commun ; 15(1): 2187, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467617

RESUMO

Advancements in congenital heart surgery have heightened the importance of durable biomaterials for adult survivors. Dystrophic calcification poses a significant risk to the long-term viability of prosthetic biomaterials in these procedures. Herein, we describe the natural history of calcification in the most frequently used vascular conduits, expanded polytetrafluoroethylene grafts. Through a retrospective clinical study and an ovine model, we compare the degree of calcification between tissue-engineered vascular grafts and polytetrafluoroethylene grafts. Results indicate superior durability in tissue-engineered vascular grafts, displaying reduced late-term calcification in both clinical studies (p < 0.001) and animal models (p < 0.0001). Further assessments of graft compliance reveal that tissue-engineered vascular grafts maintain greater compliance (p < 0.0001) and distensibility (p < 0.001) than polytetrafluoroethylene grafts. These properties improve graft hemodynamic performance, as validated through computational fluid dynamics simulations. We demonstrate the promise of tissue engineered vascular grafts, remaining compliant and distensible while resisting long-term calcification, to enhance the long-term success of congenital heart surgeries.


Assuntos
Prótese Vascular , Calcinose , Ovinos , Animais , Estudos Retrospectivos , Calcinose/cirurgia , Materiais Biocompatíveis , Politetrafluoretileno
11.
Molecules ; 29(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38474448

RESUMO

Prosthetic infections are associated with high morbidity, mortality, and relapse rates, making them still a serious problem for implantology. Staphylococcus aureus is one of the most common bacterial pathogens causing prosthetic infections. In response to the increasing rate of bacterial resistance to commonly used antibiotics, this work proposes a method for combating pathogenic microorganisms by modifying the surfaces of synthetic polymeric biomaterials using proteolytic enzyme inhibitors (serine protease inhibitors-4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride and puromycin). While using techniques based on the immobilization of biologically active molecules, it is important to monitor the changes occurring on the surface of the modified biomaterial, where spectroscopic techniques (e.g., FTIR) are ideal. ATR-FTIR measurements demonstrated that the immobilization of both inhibitors caused large structural changes on the surface of the tested vascular prostheses (polyester or polytetrafluoroethylene) and showed that they were covalently bonded to the surfaces of the biomaterials. Next, the bactericidal and antibiofilm activities of the tested serine protease inhibitors were determined using the CLSM microscopic technique with fluorescent staining. During LIVE/DEAD analyses, a significant decrease in the formation of Staphylococcus aureus biofilm after exposure to selected concentrations of native inhibitors (0.02-0.06 mg/mL for puromycin and 0.2-1 mg/mL for 4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride) was demonstrated.


Assuntos
Anti-Infecciosos , Infecções Estafilocócicas , Sulfonas , Humanos , Prótese Vascular , Antibacterianos/farmacologia , Biofilmes , Inibidores de Serino Proteinase/farmacologia , Staphylococcus aureus , Materiais Biocompatíveis , Puromicina , Peptídeo Hidrolases
12.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479833

RESUMO

OBJECTIVES: The Ross procedure represents an excellent treatment option in younger patients with aortic stenosis but is limited by poor availability of homografts. In this study, we investigated the hydrodynamic performance of 3 different types of right ventricular outflow tract replacement with pericardium or synthetic material. METHODS: Three different types of valved conduits were constructed using pericardium and/or synthetic material (Group PEPE: pericardial cusps and pericardial conduit, Group PEPR: pericardial cusps and Dacron conduit, Group PRPR: expanded polytetrafluoroethylene cusps and Dacron conduit). The conduits were designed according to the Ozaki method. Their hydrodynamic performance (effective orifice area, mean pressure gradient and leakage volume) were evaluated in a mock circulation loop at different hydrodynamic conditions. RESULTS: Hydrodynamic assessment showed significantly larger effective orifice area of PEPE and PEPR compared to PRPR under all conditions and there were no significant differences between PEPE and PEPR [for condition 2: PEPE 2.43 (2.35-2.54) cm2, PEPR: 2.42 (2.4-2.5) cm2, PRPR: 2.08 (1.97-2.21) cm2, adjusted pairwise comparisons: PEPE versus PEPR: P = 0.80, PEPE versus PRPR: P < 0.001, PEPR versus PRPR: P < 0.001]. Mean pressure gradient was significantly lower for PEPE and PEPR compared with PRPR, whereas no significant differences were seen between PEPE and PEPR. Leakage volume was significantly lower for PEPE and PEPR compared with PRPR under all conditions while leakage was similar between PEPE and PEPR. CONCLUSIONS: Pulmonary graft reconstruction with pericardium cusps showed superior hydrodynamic performance compared with polytetrafluoroethylene cusps. Our results suggest that it could be considered as an alternative substitute for right ventricular outflow tract replacement during the Ross procedure.


Assuntos
Próteses Valvulares Cardíacas , Obstrução do Fluxo Ventricular Externo , Humanos , Polietilenotereftalatos , Prótese Vascular , Desenho de Prótese , Obstrução do Fluxo Ventricular Externo/cirurgia , Politetrafluoretileno , Resultado do Tratamento , Estudos Retrospectivos
13.
Biomed Mater ; 19(3)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38430567

RESUMO

In our previous study, the pristine bilayer small-diameterin situtissue engineered vascular grafts (pTEVGs) were electrospun from a heparinized polycaprolactone (PCL45k) as an inner layer and a non-heparinized PCL80k as an outer layer in the thickness of about 131 µm and 202 µm, respectively. However, the hydrophilic enhancement of inner layer stemmed from the heparinization accelerated the degradation of grafts leading to the early formation of arterial aneurysms in a period of 3 months, severely hindering the perennial observation of the neo-tissue regeneration, host cell infiltration and graft remodeling in those implanted pTEVGs. Herein to address this drawback, the thickness of the outer layers was increased with PCL80k to around 268 µm, while the inner layer remained unchangeable. The thickened TEVGs named as tTEVGs were evaluated in six rabbits via a carotid artery interpositional model for a period of 9 months. All the animals kept alive and the grafts remained patent until explantation except for one whose one side of arterial blood vessels was occluded after an aneurysm occurred at 6 months. Although a significant degradation was observed in the implanted grafts at 9 month, the occurrence of aneurysms was obviously delayed compared to pTEVGs. The tissue stainings indicated that the endothelial cell remodeling was substantially completed by 3 months, while the regeneration of elastin and collagen remained smaller and unevenly distributed in comparison to autologous vessels. Additionally, the proliferation of macrophages and smooth muscle cells reached the maximum by 3 months. These tTEVGs possessing a heparinized inner layer and a thickened outer layer exhibited good patency and significantly delayed onset time of aneurysms.


Assuntos
Aneurisma , Poliésteres , Engenharia Tecidual , Animais , Coelhos , Prótese Vascular , Artérias Carótidas
14.
No Shinkei Geka ; 52(2): 263-269, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38514115

RESUMO

With the advent of high-resolution imaging and advancements in computational fluid dynamics(CFD)and computational structural mechanics(CSM)analyses, clinical simulation of endovascular intervention has gradually become feasible. Virtual stents have become indispensable for coil embolization. For braided stents, such as those with low-profile visualized intraluminal support and flow diverters, predicting postplacement elongation and contraction is challenging; however, software development has enabled more precise treatment planning. Additionally, simulations utilizing three-dimensional(3D)printer models can enable realistic simulations of procedures such as intracranial stents and Woven EndoBridge placement. This approach is beneficial for shunt disorders such as arteriovenous malformations and dural arteriovenous fistulas, offering 3D visualization of shunt access routes and intuitive treatment strategy planning, even for beginners. Furthermore, it can be applied to procedures such as open surgical clipping and nidus resection, aiding in the selection of suitable clips and considerations for ideal resection based on nidus curvature. Simulations using CFD, CSM, and 3D printers are crucial for training surgeons and handling new devices. Harnessing medicine-engineering synergy is essential, and regulatory approval(insurance coverage)and appropriate commercialization of simulations are paramount for the future.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/cirurgia , Prótese Vascular , Stents , Software , Embolização Terapêutica/métodos , Resultado do Tratamento
15.
BMC Cardiovasc Disord ; 24(1): 182, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532333

RESUMO

OBJECTIVE: To evaluate the early and mid-term outcomes of open repair in patients with thoracoabdominal aortic aneurysm (TAAA) after thoracic endovascular aortic repair (TEVAR). METHODS: This was a retrospective single center study. Data were retrospectively collected and analyzed for consecutive patients undergoing open TAAA repair (TAAAR) after TEVAR from November 2016 to June 2021. Indications for TAAAR included aneurysm progression due to endoleak, persisted false lumen perfusion, proximal/distal disease progression, and aorta rupture. The risk factor of operative mortality was analyzed by multivariable logistic regression model and the survival was evaluated by Kaplan-Meier. RESULTS: Sixty-three patients who met the inclusion criteria for the study were identified. The mean age at TAAAR was 41 ± 12 years and 43 (68.3%) were male. Marfan syndrome (MFS) was presented in 39 patients (61.9%). 60 (95.2%) patients presented with post-dissection aneurysm and 3 (4.8%) patients with degenerative aneurysm. The extent of TAAA was Crawford I in 9 (14.3%), II in 22 (34.9%), III in 23 (36.5%), and IV in 9 (14.3%). Emergent TAAAR was done in 10 (15.9%) patients, and deep hypothermic circulatory arrest was used in 22 (34.6%). Endograft was explanted in 31 (49.2%). Operative mortality was 11 (17.5%). Stroke, paraplegia, and acute kidney failure occurred in 5 (7.9%), 7 (11.1%), and 6 (9.5%) patients, respectively. Pulmonary complications occurred in 19 (30.2%) patients. The estimated survival was 74.8 ± 4.9% at 5 years. Late reoperations were performed in 2 patients at 2.5 years and 1.3 years, respectively. CONCLUSIONS: In this series of TAAA after TEVAR, TAAAR was related with a high risk of operative mortality and morbidity and the midterm outcomes represented a durable treatment and were respectable.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias
16.
J Cardiothorac Surg ; 19(1): 153, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532449

RESUMO

BACKGROUND: The Cabrol procedure has undergone various modifications and developments since its invention. However, there is a notable gap in the literature regarding meta-analyses assessing it. METHODS: A systematic review and meta-analysis was conducted to evaluate the effectiveness and long-term outcomes of the Cabrol procedure and its modifications. Pooling was conducted using random effects model. Outcome events were reported as linearized occurrence rates (percentage per patient-year) with 95% confidence intervals. RESULTS: A total of 14 studies involving 833 patients (mean age: 50.8 years; 68.0% male) were included in this meta-analysis. The pooled all-cause early mortality was 9.0% (66 patients), and the combined rate of reoperation due to bleeding was 4.9% (17 patients). During the average 4.4-year follow-up (3,727.3 patient-years), the annual occurrence rates (linearized) for complications were as follows: 3.63% (2.79-4.73) for late mortality, 0.64% (0.35-1.16) for aortic root reoperation, 0.57% (0.25-1.31) for hemorrhage events, 0.66% (0.16-2.74) for thromboembolism, 0.60% (0.29-1.26) for endocarditis, 2.32% (1.04-5.16) for major valve-related adverse events, and 0.58% (0.34-1.00) for Cabrol-related coronary graft complications. CONCLUSION: This systematic review provides evidence that the outcomes of the Cabrol procedure and its modifications are acceptable in terms of mortality, reoperation, anticoagulation, and valve-related complications, especially in Cabrol-related coronary graft complications. Notably, the majority of Cabrol procedures were performed in reoperations and complex cases. Furthermore, the design and anastomosis of the Dacron interposition graft for coronary reimplantation, considering natural anatomy and physiological hemodynamics, may promise future advancements in this field.


Assuntos
Cardiopatias , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Prótese Vascular , Valva Aórtica/cirurgia , Aorta/cirurgia , Reoperação , Cardiopatias/cirurgia
17.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459863

RESUMO

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Estudos Retrospectivos
18.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38439540

RESUMO

OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) for aortic arch aneurysms is challenging because of anatomical restrictions and the presence of cervical branches. Revascularization of the cervical branch is required when conventional commercial stent grafts are used. TEVAR using fenestrated stent grafts (FSG) often does not require additional procedures to revascularize cervical branches. This study aimed to evaluate the features and initial and midterm outcomes of TEVAR using fenestrated stent grafts. METHODS: From April 2007 to December 2016, 101 consecutive patients underwent TEVAR using fenestrated stent grafts for distal aortic arch aneurysms at a single centre. Technical success, complications, freedom from aneurysm-related death, secondary intervention and aneurysm progression were retrospectively investigated. RESULTS: All the patients underwent TEVAR using fenestrated stent grafts. The 30-day mortality rate was zero. Cerebral infarction, access route problems and spinal cord injury occurred in 4, 3 and 2 patients, respectively. Each type of endoleak was observed in 38 of the 101 patients during the course of the study; 20/38 patients had minor type 1 endoleaks at the time of discharge. The endoleak disappeared in 2 patients and showed no significant change in 8 patients; however, the aneurysm expanded over time in 10 patients. Additional treatment was performed in 8 of the 10 patients with type 1 endoleaks and dilatation of the aneurysm. The rate of freedom from aneurysm-related death during the observation period was 98%. CONCLUSIONS: TEVAR with FSG is a simple procedure, with few complications. Additional treatment has been observed to reduce aneurysm-related deaths, even in patients with endoleaks and enlarged aneurysms. Based on this study, the outcomes of endovascular repair of aortic arch aneurysms using a fenestrated stent graft seem acceptable.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Correção Endovascular de Aneurisma , Endoleak/etiologia , Stents , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Fatores de Tempo , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia
19.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38453660

RESUMO

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Masculino , Humanos , Idoso , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Isquemia do Cordão Espinal/etiologia , Paraplegia/etiologia
20.
BMJ Case Rep ; 17(3)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38521516

RESUMO

A patient in his late 30s presented with issues of retrosternal chest pain and palpitations. He had sustained a splinter injury to the left hemithorax a year ago for which he had been managed with a tube thoracostomy. During subsequent evaluations, he was found to have atrial fibrillations and a CT angiography revealed an arch of the aorta pseudoaneurysm with a fistulous communication with the innominate vein, which being a rare condition has no established treatment protocols. Endovascular salvage of the condition required an aortic Ishimaru zone 2 deployment of the thoracic endovascular aortic repair stent graft to provide an adequate landing zone. The elective left subclavian artery revascularisation was obtained by a left carotid artery to left subclavian artery bypass. Post procedure there was complete exclusion of the pseudoaneurysm sac, and the fistulous aorto-venous communication inflow tract. The patient recuperated well and has returned to full active duties.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Traumatismos Torácicos , Humanos , Masculino , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/lesões , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Veias Braquiocefálicas/diagnóstico por imagem , Veias Braquiocefálicas/cirurgia , Desenho de Prótese , Stents , Traumatismos Torácicos/cirurgia , Resultado do Tratamento , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...