Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 19.604
Filtrar
1.
BMC Surg ; 24(1): 110, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622597

RESUMO

BACKGROUND: The reporting of surgical instrument errors historically relies on cumbersome, non-automated, human-dependent, data entry into a computer database that is not integrated into the electronic medical record. The limitations of these reporting systems make it difficult to accurately estimate the negative impact of surgical instrument errors on operating room efficiencies. We set out to determine the impact of surgical instrument errors on a two-hospital healthcare campus using independent observers trained in the identification of Surgical Instrument Errors. METHODS: This study was conducted in the 7 pediatric ORs at an academic healthcare campus. Direct observations were conducted over the summer of 2021 in the 7 pediatric ORs by 24 trained student observers during elective OR days. Surgical service line, error type, case type (inpatient or outpatient), and associated length of delay were recorded. RESULTS: There were 236 observed errors affecting 147 individual surgical cases. The three most common errors were Missing+ (n = 160), Broken/poorly functioning instruments (n = 44), and Tray+ (n = 13). Errors arising from failures in visualization (i.e. inspection, identification, function) accounted for 88.6% of all errors (Missing+/Broken/Bioburden). Significantly more inpatient cases (42.73%) had errors than outpatient cases (22.32%) (p = 0.0129). For cases in which data was collected on whether an error caused a delay (103), over 50% of both IP and OP cases experienced a delay. The average length of delays per case was 10.16 min. The annual lost charges in dollars for surgical instrument associated delays in chargeable minutes was estimated to be between $6,751,058.06 and $9,421,590.11. CONCLUSIONS: These data indicate that elimination of surgical instrument errors should be a major target of waste reduction. Most observed errors (88.6%) have to do with failures in the visualization required to identify, determine functionality, detect the presence of bioburden, and assemble instruments into the correct trays. To reduce these errors and associated waste, technological advances in instrument identification, inspection, and assembly will need to be made and applied to the process of sterile processing.


Assuntos
Salas Cirúrgicas , Instrumentos Cirúrgicos , Humanos , Criança , Hospitais
2.
J Evid Based Integr Med ; 29: 2515690X241244845, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38613379

RESUMO

Garcinia dulcis (GD) extract possesses anti-hypertensive property that are poorly characterized. This study aimed to investigate an anti-inflammatory effect of GD flower extract in the 2-kidney-1-clip (2K1C) hypertensive compared to sham operative (SO) rat. Male Wistar rats were divided into 2 groups; the 2K1C group in which a silver clip was placed around renal artery to induce hypertension, and the SO normotensive group. Four weeks later, each group of rats were further divided into 2 subgroups, each subgroup was orally gavaged of either corn oil (vehicle) or 50 mg/kg BW GD extract daily for 4 weeks. The malondialdehyde (MDA) levels in serum, liver, and kidney were determined. Hematoxylin and eosin staining was carried out for histological examination, Periodic acid - Schiff staining for glomerular injury, Masson's trichrome staining for renal fibrosis, and immunohistochemistry for either tumor necrosis factor alpha (TNF-α) or endothelial nitric oxide synthase (eNOS) investigation. Taken together, our results demonstrated that GD flower extract decreased the MDA level in both serum and liver and kidney tissue and suppressed the expression of TNF-α in both liver and kidney of 2K1C hypertensive rats. Mesangial cell proliferation, expansion of mesangial matrix, widening Bowman's capsule space, congestion of glomerular capillary and vessel, cloudy swelling of renal tubular epithelial cell, and renal fibrosis were observed in the kidneys of 2K1C rats. Therefore, we concluded that GD flower extract can alleviate liver and kidney inflammation in which partially attenuates the glomerular injury in the 2K1C rat.


Assuntos
Hipertensão , Fator de Necrose Tumoral alfa , Masculino , Ratos , Animais , Fator de Necrose Tumoral alfa/genética , Ratos Wistar , Rim , Fígado , Inflamação/tratamento farmacológico , Instrumentos Cirúrgicos , Fibrose , Extratos Vegetais/farmacologia
7.
PLoS One ; 19(4): e0301590, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598515

RESUMO

To promote the comprehensive utilization of corn stover and the development of field water-saving irrigation technology, a method of returning corn stover to the field was prosed; in this method, the crop stalks were crushed, mixed with soil in different proportions of adulteration, and then extruded to form hollow round tubes. To compare the influence of the winch blade with or without a diameter change on the composite pipe molding performance, two composite pipe molding devices were theoretically designed, simulated, and analyzed using discrete element simulation software, and a composite pipe molding bench test was performed. The simulation test revealed that the composite pipe molding rate of the winch blade without the reducer molding device was 3.45 kg/s, the output power of the winch shaft was 20.7 kW, the composite pipe molding rate of the winch blade with the reducer molding device was 1.20 kg/s, and the output power of the winch shaft was 18.75 kW. By calculating the weighted average of two indices, the composite pipe forming rate and the winch shaft output power, the comprehensive performance index of the composite pipe forming device without a reducer was greater than that of the device with a reducer. The composite pipe forming bench test revealed two kinds of molding devices with an extrusion molding with an outer diameter of 100 mm and an inner diameter of 30 mm. The composite pipe density test average was greater than 1.30 g/cm3 and met the requirements of composite pipe molding; the winch blade without a reducer molding device had an average composite pipe molding rate of 3.23 kg/s, and the winch blade with an average reducer molding rate of 2.07 kg/s. The forming rate of the composite pipe without a reducer was faster. Therefore, a winch blade without a reducer composite pipe molding device is more conducive to improving the composite pipe molding performance.


Assuntos
Instrumentos Cirúrgicos , Zea mays , Tecnologia , Solo , Água
8.
World J Surg Oncol ; 22(1): 91, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600546

RESUMO

OBJECTIVE: To compare the efficacy of ultrasounic-harmonic scalpel and electrocautery in the treatment of axillary lymph nodes during radical surgery for breast cancer. METHODS: A prospective study was conducted in the Department of Breast Surgery, Zhongda Hospital Affiliated to Southeast University. A total of 128 patients with pathologically confirmed breast cancer who were treated by the same surgeon from July 2023 to November 2023 were included in the analysis. All breast operations were performed using electrocautery, and surgical instruments for axillary lymph nodes were divided into ultrasounic-harmonic scalpel group and electrocautery group using a random number table. According to the extent of lymph node surgery, it was divided into four groups: sentinel lymph node biopsy, lymph node at station I, lymph node at station I and II, and lymph node dissection at station I, II and III. Under the premise of controlling variables such as BMI, age and neoadjuvant chemotherapy, the effects of ultrasounic-harmonic scalpel and electrocautery in axillary surgery were compared. RESULTS: Compared with the electrosurgical group, there were no significant differences in lymph node operation time, intraoperative blood loss, postoperative axillary drainage volume, axillary drainage tube indwelling time, postoperative pain score on the day after surgery, and the incidence of postoperative complications (p>0.05). CONCLUSION: There is no significant difference between ultrasounic-harmonic scalpel and electrocautery in axillary lymph node treatment for breast cancer patients, which can provide a basis for the selection of surgical energy instruments.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Estudos Prospectivos , Excisão de Linfonodo , Biópsia de Linfonodo Sentinela , Instrumentos Cirúrgicos , Eletrocoagulação/efeitos adversos , Linfonodos/cirurgia , Linfonodos/patologia , Axila/patologia
10.
Int J Colorectal Dis ; 39(1): 41, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520546

RESUMO

PURPOSE: Tattoo markings are often used as preoperative markers for colorectal cancer. However, scattered ink markings adversely affect tumor site recognition intraoperatively; therefore, interventions for rectal cancer may lead to an inaccurate distal resection margin (DRM) and incomplete total mesorectal excision (TME). This is the first case series of fluorescence-guided robotic rectal surgery in which near-infrared fluorescence clips (NIRFCs) were used to localize rectal cancer lesions. METHODS: We enrolled 20 consecutive patients who underwent robotic surgery for rectal cancer between December 2022 and December 2023 in the current study. The primary endpoints were the rate of intraoperative clip detection and its usefulness for marking the tumor site. Secondary endpoints were oncological assessments, including DRM and the number of lymph nodes. RESULTS: Clip locations were confirmed in 17 of 20 (85%) patients. NIRFCs were not detected in 3 out of 7 patients who underwent preoperative chemoradiation therapy. No adverse events, including bleeding or perforation, were observed at the time of clipping, and no clips were lost. The median DRM was 55 mm (range, 22-86 mm) for rectosigmoid (Rs), 33 mm (range, 16-60 mm) for upper rectum (Ra), and 20 mm (range, 17-30 mm) for low rectum (Rb). The median number of lymph nodes was 13 (range, 10-21). CONCLUSION: The rate of intraoperative clip detection, oncological assessment, including DRM, and the number of lymph nodes indicate that the utility of fluorescence-guided methods with NIRFCs is feasible for rectal cancer.


Assuntos
Laparoscopia , Neoplasias Retais , Procedimentos Cirúrgicos Robóticos , Humanos , Reto/cirurgia , Reto/patologia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Estudos Retrospectivos , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Corantes , Instrumentos Cirúrgicos , Laparoscopia/métodos
11.
Ann Med ; 56(1): 2301596, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38478750

RESUMO

BACKGROUND: Rapid Cycle Deliberate Practice (RCDP) has gained prominence in recent years as an innovative teaching method in simulation-based training for adult and pediatric emergency medical skills. However, its application in the training of forceps delivery skills among obstetrics and gynecology residents remains unexplored. This study aimed to assess the impact of RCDP in this domain. METHODS: Conducted in March 2021, this randomized controlled study involved 60 second-year obstetrics and gynecology residents undergoing standardized training. Participants were randomly assigned to the RCDP group or the traditional teaching method (TTM) group, each comprising 30 residents. The RCDP group followed the RCDP practice mode, while the TTM group adhered to conventional simulation teaching. Post-training assessment of operational proficiency was conducted immediately and after one year. Independent operational confidence and training satisfaction were evaluated through questionnaire surveys and the Satisfaction with Simulation Experience (SSE) scale. Data analysis utilized SPSS 23.0. RESULTS: The RCDP group displayed significantly higher immediate post-training forceps operation scores compared to the TTM group (92.00 [range: 90.00-94.00] vs. 88.00 [range: 86.75-92.00]; z = 3.79; p < .001). However, no significant difference emerged in forceps operation scores after one year (86.00 [range: 85.00-88.00] vs. 85.50 [range: 84.00-88.25]; z = 0.54; p = .59). The RCDP group exhibited notable performance improvement over the TTM group (z = 3.49; p < .001). Independent operation confidence showed no significant discrepancy (p > .05). Importantly, the RCDP group reported higher satisfaction scores, particularly in the Debriefing and Reflection subscale (44.00 [range: 43.00-45.00] vs. 41.00 [range: 41.50-43.00]; z = 5.24; p < .001), contributing to an overall superior SSE score (z = 4.74; p < .001). CONCLUSIONS: RCDP exhibits immediate efficacy in elevating forceps delivery skills among residents. However, sustained skill enhancement necessitates innovative approaches, while RCDP's value lies in tailored feedback and reflection for enriched medical education.


Rapid Cycle Deliberate Practice (RCDP) demonstrates immediate effectiveness in enhancing forceps delivery skills among obstetrics and gynecology residents, leading to improved immediate performance, which also increased their satisfaction with the teaching process and operational confidence.Long-term skill retention through RCDP appears limited, highlighting the importance of ongoing reinforcement to prevent skill decay and maintain proficiency.


Assuntos
Ginecologia , Internato e Residência , Treinamento por Simulação , Humanos , Competência Clínica , Ginecologia/educação , Instrumentos Cirúrgicos
12.
Fam Pract ; 41(2): 147-154, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38518797

RESUMO

BACKGROUND: Speculum examination is an intrusive practice in the clinical care of women. It requires privacy and patients may experience discomfort or anxiety related to the procedure, which can result in delays or avoidance of necessary healthcare. Speculum self-insertion originated in the United States in the 1970s as part of the self-help movement. However, this clinical practice is largely unknown among healthcare providers and has rarely been assessed. AIM: This study investigates the women's views and healthcare providers' experiences of the self-insertion method. METHOD: A qualitative study was conducted between December 2021 and October 2022, including fieldwork combining semi-structured interviews (10 women) and focus groups associated with individual interviews of 13 healthcare providers. The data collected were independently coded by 2 authors and analysed using an inductive approach and grounded theory method. RESULTS: Speculum self-insertion was described as a way to decrease discomfort and facilitate speculum insertion. Self-insertion was proposed as a means of allowing women to participate in the examination, reducing their vulnerability against power imbalances in the doctor-patient relationship. Both patients and healthcare providers have reported that speculum self-insertion is a method that can contribute to improving trust and communication during the examination. CONCLUSION: The practice of speculum self-insertion during the consultation is an alternative to traditional practitioner insertion and may be offered to all women by any practitioner who wishes to use this technique.


The use of a speculum is common in gynaecological consultations and most women are likely to encounter this tool during a medical examination. Several studies have already shown that this examination can cause pain and anxiety. Speculum self-insertion is not widely used and consists of allowing the woman to insert the speculum herself while being assisted by the practitioner. A study was conducted with 10 women and 13 healthcare providers to evaluate this technique and its impact on women's healthcare. This technique reduces the discomfort that can be felt during the examination. The woman will regain control of her body during the examination and this technique will reduce the hierarchical relationship felt by some women. A discussion about the gynaecological examination and women's healthcare is created during the consultation. Even if this technique does not seem to be suitable for all women, routinely offering self-insertion allows the healthcare provider to adapt to each woman and to her choice. The proposal of speculum self-insertion is an alternative technique that can improves women's feelings and their overall health.


Assuntos
Exame Ginecológico , Relações Médico-Paciente , Feminino , Humanos , Instrumentos Cirúrgicos , Pessoal de Saúde , Ansiedade
13.
J Cancer Res Clin Oncol ; 150(3): 145, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507110

RESUMO

OBJECTIVE: To investigate the superiority of preoperative ultrasound-guided titanium clip and nanocarbon dual localization over traditional methods for determining the surgical approach and guiding resection of Siewert type II adenocarcinoma of the esophagogastric junction (AEG). METHOD: This study included 66 patients with Siewert type II AEG who were treated at the PLA Joint Logistics Support Force 900th Hospital between September 1, 2021, and September 1, 2023. They were randomly divided into an experimental group (n = 33), in which resection was guided by the dual localization technique, and the routine group (n = 33), in which the localization technique was not used. Surgical approach predictions, proximal esophageal resection lengths, pathological features, and the occurrence of complications were compared between the groups. RESULT: The use of the dual localization technique resulted in higher accuracy in predicting the surgical approach (96.8% vs. 75.9%, P = 0.02) and shorter proximal esophageal resection lengths (2.39 ± 0.28 cm vs. 2.86 ± 0.39 cm, P < 0.001) in the experimental group as compared to the routine group, while there was no significant difference in the incidence of postoperative complications (22.59% vs. 24.14%, P = 0.88). CONCLUSION: Preoperative dual localization with titanium clips and carbon nanoparticles is significantly superior to traditional methods and can reliably delineate the actual infiltration boundaries of Siewert type II AEG, guide the surgical approach, and avoid excessive esophageal resection.


Assuntos
Adenocarcinoma , Neoplasias Esofágicas , Nanopartículas , Neoplasias Gástricas , Humanos , Titânio , Estudos Retrospectivos , Neoplasias Gástricas/patologia , Gastrectomia/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/cirurgia , Adenocarcinoma/patologia , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/patologia , Junção Esofagogástrica/diagnóstico por imagem , Junção Esofagogástrica/cirurgia , Junção Esofagogástrica/patologia , Instrumentos Cirúrgicos , Ultrassonografia de Intervenção , Carbono
15.
Kyobu Geka ; 77(1): 35-37, 2024 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-38459843

RESUMO

Oral anticoagulants for atrial fibrillation are the standard approach to prevent stroke in patients with atrial fibrillation. However, oral anticoagulant therapy carries the risk of cerebral infarction recurrence, not to mention hemorrhagic complications, even under appropriate drug therapy. Surgical treatments targeting the left atrial appendage include left atrial appendage closure( LAAO) and left atrial appendage resection (LAAR). Our hospital uses AtriClip (approved and available in Japan since 2018) as a device for LAAO, and we investigated the early and long-term results of LAAO using AtriClip in our hospital. As a result, stable early to long-term results were expected for left atrial appendage closure using AtriClip device, suggesting that it may be an option that can be considered as a method for preventing stroke in patients with atrial fibrillation. But further investigation is required in the future.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , 60589 , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes/uso terapêutico , Instrumentos Cirúrgicos/efeitos adversos , Resultado do Tratamento
16.
Langenbecks Arch Surg ; 409(1): 89, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38457041

RESUMO

PURPOSE: Polymeric clips (Hem-o-lok ligation system) are now widely used to securing the base of the appendix during laparoscopic appendectomy. Studies comparing the use of single or double hem-o-lok clips are limited. The aim of this study was to compare the reliability of a single hem-o-lok clips with a double hem-o-lok clips for closure of an appendiceal stump. METHODS: This prospective randomized study includes patients from two centers who underwent laparoscopic appendectomy with the diagnosis of appendicitis between September 2020 and March 2023. Demographic, operative and clinical outcomes of the use of single or double hem-o-lok clips for closure of the appendiceal stump were compared. Factors affecting long postoperative hospital stay were investigated using univariate and multivariate analyzes. RESULTS: One hundred forty two (48.3%) patients in the single hem-o-lok arm and 152 (51.7%) patients in the double hem-o-lok arm were included in the analysis.The shortest operative time was noted in the single hem-o-lok group (52.1 ± 19.9 versus 61.6 ± 24.9 min, p < 0.001). The median hospital stay was 1 day (range 1-10) in the single hem-o-lok group and 1 day (range 1-12) in the double hem-o-lok group, and was shorter in the single hem-o-lok arm (1.61 ± 1.56 vs 1.84 ± 1.69, p = 0.019). Based on multivariate analysis, drain placement was identified as an independent predictive factor for long hospital stay. CONCLUSIONS: The use of single hem-o-lok clips for appendiceal stump closure during laparoscopic appendectomy is safe and effective. Trial registration NCT04387370 ( http://www. CLINICALTRIALS: gov ).


Assuntos
Apendicite , Laparoscopia , Humanos , Apendicectomia , Estudos Prospectivos , Reprodutibilidade dos Testes , Apendicite/cirurgia , Instrumentos Cirúrgicos
19.
Int J Med Robot ; 20(2): e2624, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38430543

RESUMO

BACKGROUND: The aim of this study was to investigate 8-mm robotic trocar site hernia (TSH) rate over the short and long term, providing aids to manage the related fascial wounds. METHODS: A retrospective analysis of 320 patients undergoing robotic surgery was conducted. The primary outcome was 8-mm TSH rate with a minimum follow-up of 12 months. The secondary outcome was the rate of haematomas and infections related to 8-mm wounds and their association with patient comorbidities and trocar position. RESULTS: One case of TSH was observed (0.31%). There were 15 cases of wound infection (4.68%) and 22 cases of wound haematoma (6.87%). Trocar related complications were significantly associated with patient comorbidities, not with trocar position. CONCLUSIONS: Our results do not justify the 8-mm fascial wound closure. Data concerning the association between trocar-related complications and patient comorbidities strengthen the need to implement the control of metabolic state and correct administration of perioperative therapy in high-risk patients.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Estudos Retrospectivos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Instrumentos Cirúrgicos/efeitos adversos , Tireotropina
20.
J Hosp Infect ; 143: 1-7, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38529779

RESUMO

BACKGROUND: Using robots to handle medical devices in the decontamination area of the Central Sterile Supply Department (CSSD) can reduce risks and address staff shortages. The gripper design must allow reliable cleaning using standard CSSD procedures to avoid build-up of biofilms and possible cross-contamination between different instrument trays and the gripper's functionality. This study explores the design of the robot's gripper regarding cleanability, aiming to determine whether successful cleaning can be achieved even after prolonged drying for a working shift of 8 h. METHODS: We optimized a gripper for cleanability and used it to assess the spread of different test soils depending on different forms of motion. Subsequently, we analysed the cleanability using sheep's blood as test soil, reprocessing the gripper in different assembly configurations after 4 and 8 h of drying, and measuring residual protein. FINDINGS: Based on our investigations, we documented the spread of contamination depending on the type of motion of the gripper's components. Sheep's blood exhibited the highest dispersion among the test soils, permeating through thin crevices. Importantly, all samples displayed residual protein levels below the warning threshold, irrespective of drying time and gripper disassembly or cleaning position. Cleaning in a device-specific optimized position achieved results comparable to cleaning the disassembled individual components. CONCLUSIONS: These findings indicate that cleaning even after one working shift of 8 h and without the labour-intensive disassembly of the gripper is feasible, supporting the future use of robots to handle contaminated medical devices in the CSSD decontamination area.


Assuntos
Robótica , Humanos , Descontaminação/métodos , Contaminação de Equipamentos/prevenção & controle , Instrumentos Cirúrgicos , Solo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...