Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.269
Filtrar
1.
Nano Lett ; 24(15): 4588-4594, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38587406

RESUMO

Effective thawing of cryopreserved samples requires rapid and uniform heating. This is achievable through nanowarming, an approach that heats magnetic nanoparticles by using alternating magnetic fields. Here we demonstrate the synthesis and surface modification of magnetic nanoclusters for efficient nanowarming. Magnetite (Fe3O4) nanoclusters with an optimal diameter of 58 nm exhibit a high specific absorption rate of 1499 W/g Fe under an alternating magnetic field at 43 kA/m and 413 kHz, more than twice that of commercial iron oxide cores used in prior nanowarming studies. Surface modification with a permeable resorcinol-formaldehyde resin (RFR) polymer layer significantly enhances their colloidal stability in complex cryoprotective solutions, while maintaining their excellent heating capacity. The Fe3O4@RFR nanoparticles achieved a high average heating rate of 175 °C/min in cryopreserved samples at a concentration of 10 mg Fe/mL and were successfully applied in nanowarming porcine iliac arteries, highlighting their potential for enhancing the efficacy of cryopreservation.


Assuntos
Calefação , Magnetismo , Suínos , Animais , Criopreservação , Óxido Ferroso-Férrico , Campos Magnéticos
2.
Sci Rep ; 14(1): 7879, 2024 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570608

RESUMO

Achieving non-invasive spatiotemporal control over cellular functions, tissue organization, and behavior is a desirable aim for advanced therapies. Magnetic fields, due to their negligible interaction with biological matter, are promising for in vitro and in vivo applications, even in deep tissues. Particularly, the remote manipulation of paramagnetic (including superparamagnetic and ferromagnetic, all with a positive magnetic susceptibility) entities through magnetic instruments has emerged as a promising approach across various biological contexts. However, variations in the properties and descriptions of these instruments have led to a lack of reproducibility and comparability among studies. This article addresses the need for standardizing the characterization of magnetic instruments, with a specific focus on their ability to control the movement of paramagnetic objects within organisms. While it is well known that the force exerted on magnetic particles depends on the spatial variation (gradient) of the magnetic field, the magnitude of the field is often overlooked in the literature. Therefore, we comprehensively analyze and discuss both actors and propose a novel descriptor, termed 'effective gradient', which combines both dependencies. To illustrate the importance of both factors, we characterize different magnet systems and relate them to experiments involving superparamagnetic nanoparticles. This standardization effort aims to enhance the reproducibility and comparability of studies utilizing magnetic instruments for biological applications.


Assuntos
Magnetismo , Nanopartículas , Reprodutibilidade dos Testes , Imãs , Campos Magnéticos
3.
Int J Mol Sci ; 25(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38612456

RESUMO

Platelets are actively involved in tissue injury site regeneration by producing a wide spectrum of platelet-derived growth factors such as PDGF (platelet-derived growth factor), IGF-1 (insulin-like growth factor), TGF-ß1 (transforming growth factor ß), FGF (fibroblast growth factor), etc. A rotating magnetic field (RMF) can regulate biological functions, including reduction or induction regarding inflammatory processes, cell differentiation, and gene expression, to determine the effect of an RMF on the regenerative potential of platelets. The study group consisted of 30 healthy female and male volunteers (n = 15), from which plasma was collected. A portion of the plasma was extracted and treated as an internal control group. Subsequent doses of plasma were exposed to RMF at different frequencies (25 and 50 Hz) for 1 and 3 h. Then, the concentrations of growth factors (IGF-1, PDGF-BB, TGF-ß1, and FGF-1) were determined in the obtained material by the ELISA method. There were statistically significant differences in the PDGF-BB, TGF-ß1, IGF-1, and FGF-1 concentrations between the analyzed groups. The highest concentration of PDGF-BB was observed in the samples placed in RMF for 1 h at 25 Hz. For TGF-ß1, the highest concentrations were obtained in the samples exposed to RMF for 3 h at 25 Hz and 1 h at 50 Hz. The highest concentrations of IGF-1 and FGF-1 were shown in plasma placed in RMF for 3 h at 25 Hz. An RMF may increase the regenerative potential of platelets. It was noted that female platelets may respond more strongly to RMF than male platelets.


Assuntos
Fator 1 de Crescimento de Fibroblastos , Fator de Crescimento Insulin-Like I , Humanos , Feminino , Masculino , Becaplermina , Fator de Crescimento Transformador beta1 , Fatores de Crescimento de Fibroblastos , Fator de Crescimento Derivado de Plaquetas , Campos Magnéticos
4.
PLoS One ; 19(4): e0301852, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625980

RESUMO

In view of the growing role of magnetic particles under magnetic field influence in medical and other applications, and perforce the bead chaining, it is important to understand more generally the chain dynamics. As is well known, in the presence of a magnetic field, magnetic beads tend to form chains that are aligned with the magnetic field vector. In addition, if there is a magnetic field gradient, there will be a magnetic force acting on this chain. The main goal of the present research is to study the motion of a magnetic bead chain that makes an arbitrary angle with the magnetic force vector in the Stokes flow limit, that is, in the limit of zero Reynolds number. We used the public-domain computer program HYDRO++ to calculate the mobility matrix, which relates the magnetic force acting on the chain to the velocity of the chain, for a chain of N beads making an arbitrary angle with the magnetic force vector. Because of the presence of off-diagonal elements of the mobility matrix, as the chain is drawn in the direction of the magnetic force, it is also deflected to the side. We derived analytic solutions for this motion. Also, for bead chains moving in directions both parallel and perpendicular to their lengths, we fit three-parameter functions to solutions from HYDRO++. We found the fits to be excellent. Combining these results with the analytic solutions, we obtained expressions for the velocity components for the bead chains that provide excellent fits to HYDRO++ solutions for arbitrary angles. Finally, we apply the methodology used for the bead chain studies to the study of an obliquely falling rod in a viscous fluid and derive analytic solutions for the velocity components of the obliquely falling rod.


Assuntos
Acidentes por Quedas , Magnetismo , Fenômenos Físicos , Movimento (Física) , Campos Magnéticos
5.
Methods Enzymol ; 694: 1-49, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38492947

RESUMO

Magnetic tweezers have become popular with the outbreak of single molecule micromanipulation: catching a single molecule of DNA, RNA or a single protein and applying mechanical constrains using micron-size magnetic beads and magnets turn out to be easy. Various factors have made this possible: the fact that manufacturers have been preparing these beads to catch various biological entities-the ease of use provided by magnets which apply a force or a torque at a distance thus inside a flow cell-some chance: since the forces so generated are in the right range to stretch a single molecule. This is a little less true for torque. Finally, one feature which also appears very important is the simplicity of their calibration using Brownian motion. Here we start by describing magnetic tweezers used routinely in our laboratory where we have tried to develop a device as simple as possible so that the experimentalist can really focus on the biological aspect of the biomolecules that he/she is interested in. We discuss the implications of the various components and their important features. Next, we summarize what is easy to achieve and what is less easy. Then we refer to contributions by other groups who have brought valuable insights to improve magnetic tweezers.


Assuntos
Magnetismo , Imãs , Magnetismo/métodos , DNA , Campos Magnéticos , Movimento (Física) , Pinças Ópticas
6.
Bioinspir Biomim ; 19(3)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38452388

RESUMO

Certain animal species use the Earth's magnetic field (i.e. magnetoreception) alongside their other sensory modalities to navigate long distances that include continents and oceans. It is hypothesized that several animals use geomagnetic parameters, such as field intensity and inclination, to recognize specific locations or regions, potentially enabling migration without a pre-surveyed map. However, it is unknown how animals use geomagnetic information to generate guidance commands, or where in the world this type of strategy would maximize an animal's fitness. While animal experiments have been invaluable in advancing this area, the phenomenon is difficult to studyin vivoorin situ, especially on the global scale where the spatial layout of the geomagnetic field is not constant. Alongside empirical animal experiments, mathematical modeling and simulation are complementary tools that can be used to investigate animal navigation on a global scale, providing insights that can be informative across a number of species. In this study, we present a model in which a simulated animal (i.e. agent) navigates via an algorithm which determines travel heading based on local and goal magnetic signatures (here, combinations of geomagnetic intensity and inclination) in a realistic model of Earth's magnetic field. By varying parameters of the navigation algorithm, different regions of the world can be made more or less reliable to navigate. We present a mathematical analysis of the system. Our results show that certain regions can be navigated effectively using this strategy when these parameters are properly tuned, while other regions may require more complex navigational strategies. In a real animal, parameters such as these could be tuned by evolution for successful navigation in the animal's natural range. These results could also help with developing engineered navigation systems that are less reliant on satellite-based methods.


Assuntos
Campos Magnéticos , Magnetismo , Animais , Sensação , Oceanos e Mares , Modelos Biológicos
7.
Sci Rep ; 14(1): 6597, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504094

RESUMO

Transcranial static magnetic field stimulation (tSMS) is a non-invasive brain stimulation technique that is portable and easy to use. Long-term, home-based treatments with tSMS of the supplementary motor area (SMA) are promising for movement disorders and other brain diseases. The aim of the present work was to investigate the potential of SMA-tSMS for reducing corticospinal excitability. We completed an open pilot study in which twenty right-handed healthy subjects (8 females; age: 31.3 ± 5.4 years) completed two 30-min sessions (at least one week apart) of SMA-tSMS. We assessed corticospinal excitability by applying transcranial magnetic stimulation (TMS) over the primary motor cortex, recording 30 motor evoked potentials (MEPs) from either the left or right first dorsal interosseous (FDI, 'hotspot' muscle) and extensor carpi radialis (ECR, 'offspot' muscle) in each session before and after (up to 30 min) tSMS. We observed moderate-to-extreme level of Bayesian evidence for a reduction of MEP amplitude after 30 min of tSMS over SMA compared to baseline. Thus, tSMS applied over SMA may reduce corticospinal excitability. These findings, if confirmed with double-blind, placebo-controlled experiments, support the potential of targeting the SMA for neuromodulating a large motor network in future therapeutic applications of tSMS.


Assuntos
Córtex Motor , Estimulação Magnética Transcraniana , Feminino , Humanos , Adulto , Estimulação Magnética Transcraniana/métodos , Córtex Motor/fisiologia , Projetos Piloto , Teorema de Bayes , Potencial Evocado Motor/fisiologia , Campos Magnéticos , Músculo Esquelético/fisiologia
8.
ACS Appl Mater Interfaces ; 16(14): 17339-17346, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38531044

RESUMO

Living organisms inspire the design of microrobots, but their functionality is unmatched. Next-generation microrobots aim to leverage the sensing and communication abilities of organisms through magnetic hybridization, attaching magnetic particles to them for external control. However, the protocols used for magnetic hybridization are morphology specific and are not generalizable. We propose an alternative approach that leverages the principles of negative magnetostatics and magnetophoresis to control nonmagnetic organisms with external magnetic fields. To do this, we disperse model organisms in dispersions of Fe3O4 nanoparticles and expose them to either uniform or gradient magnetic fields. In uniform magnetic fields, living organisms align with the field due to external torque, while gradient magnetic fields generate a negative magnetophoretic force, pushing objects away from external magnets. The magnetic fields enable controlling the position and orientation of Caenorhabditis elegans larvae and flagellated bacteria through directional interactions and magnitude. This control is diminished in live spermatozoa and adult C. elegans due to stronger internal biological activity, i.e., force/torque. Our study presents a method for spatiotemporal organization of living organisms without requiring magnetic hybridization, opening the way for the development of controllable living microbiorobots.


Assuntos
Caenorhabditis elegans , Nanopartículas , Animais , Magnetismo , Imãs , Campos Magnéticos
9.
Int J Biol Macromol ; 264(Pt 2): 130525, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38431004

RESUMO

To realize the maximum therapeutic activity of medicine and protect the body from the adverse effects of active ingredients, drug delivery systems (DDS) featured with targeted transportation sites and controllable release have captured extensive attention over the past decades. Hydrogels with unique three-dimensional (3D) porous structures present tunable capacity, controllable degradation, various stimuli sensitivity, therapeutic agents encapsulation, and loaded drugs protection properties, which endow hydrogels with bred-in-the-bone advantages as vehicles for drug delivery. In recent years, with the impressive consciousness of the "back-to-nature" concept, biomass materials are becoming the 'rising star' as the hydrogels building blocks for controlled drug release carriers due to their biodegradability, biocompatibility, and non-toxicity properties. In particular, cellulose and its derivatives are promising candidates for fabricating hydrogels as their rich sources and high availability, and various smart cellulose-based hydrogels as targeted carriers under exogenous such as light, electric field, and magnetic field or endogenous such as pH, temperature, ionic strength, and redox gradients. In this review, we summarized the main synthetic strategies of smart cellulose-based hydrogels including physical and chemical cross-linking, and illustrated the detailed intelligent-responsive mechanism of hydrogels in DDS under external stimulus. Additionally, the ongoing development and challenges of cellulose-based hydrogels in the biomedical field are also presented.


Assuntos
Celulose , Hidrogéis , Celulose/química , Hidrogéis/química , Sistemas de Liberação de Medicamentos/métodos , Portadores de Fármacos , Campos Magnéticos
10.
Food Chem ; 447: 138990, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38492306

RESUMO

This study investigated the combined effects of direct-current magnetic field (DC-MF, 9.5 mT) and tetrasodium-pyrophosphate (TSPP, 1-5 g/L) on emulsified gel properties of porcine myofibrillar protein (MP). Results showed that MP at DC-MF and 3 g/L TSPP had decreased spectrum intensity of UV and fluorescence compared to that without DC-MF, owing to the changes of MP tertiary structure caused by DC-MF, especially tryptophan and tyrosine. The emulsion treated with DC-MF behaved better emulsifying activity and stability than that without DC-MF under such condition. And emulsion had lower creaming index and better storage stability. Gels prepared by this MP emulsion had low porosity and stable structure, accompanying with smaller size and more uniform distribution of oil droplets. Microstructure images showed that gels were covered with microporous structure, which was conducive to the good WHC of the emulsified gels (97.12%). These results showed the feasibility of DC-MF and TSPP in improving MP emulsion/emulsified gel.


Assuntos
Proteínas Musculares , Fosfatos , Animais , Suínos , Emulsões/química , Proteínas Musculares/química , Géis/química , Campos Magnéticos
11.
J Colloid Interface Sci ; 664: 454-468, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38484514

RESUMO

Nowadays, diseases associated with an ageing population, such as osteoporosis, require the development of new biomedical approaches to bone regeneration. In this regard, mechanotransduction has emerged as a discipline within the field of bone tissue engineering. Herein, we have tested the efficacy of superparamagnetic iron oxide nanoparticles (SPIONs), obtained by the thermal decomposition method, with an average size of 13 nm, when exposed to the application of an external magnetic field for mechanotransduction in human bone marrow-derived mesenchymal stem cells (hBM-MSCs). The SPIONs were functionalized with an Arg-Gly-Asp (RGD) peptide as ligand to target integrin receptors on cell membrane and used in colloidal state. Then, a comprehensive and comparative bioanalytical characterization of non-targeted versus targeted SPIONs was performed in terms of biocompatibility, cell uptake pathways and mechanotransduction effect, demonstrating the osteogenic differentiation of hBM-MSCs. A key conclusion derived from this research is that when the magnetic stimulus is applied in the first 30 min of the in vitro assay, i.e., when the nanoparticles come into contact with the cell membrane surface to initiate endocytic pathways, a successful mechanotransduction effect is observed. Thus, under the application of a magnetic field, there was a significant increase in runt-related transcription factor 2 (Runx2) and alkaline phosphatase (ALP) gene expression as well as ALP activity, when cells were exposed to RGD-functionalized SPIONs, demonstrating osteogenic differentiation. These findings open new expectations for the use of remotely activated mechanotransduction using targeted magnetic colloidal nanoformulations for osteogenic differentiation by drug-free cell therapy using minimally invasive techniques in cases of bone loss.


Assuntos
Mecanotransdução Celular , Osteogênese , Humanos , Diferenciação Celular , Campos Magnéticos , Oligopeptídeos/farmacologia , Células Cultivadas
12.
Phys Med Biol ; 69(8)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38479018

RESUMO

Objective.To investigate the reliability and accuracy of the manual three-point co-registration in neuronavigated transcranial magnetic stimulation (TMS). The effect of the error in landmark pointing on the coil placement and on the induced electric and magnetic fields was examined.Approach.The position of the TMS coil on the head was recorded by the neuronavigation system and by 3D scanning for ten healthy participants. The differences in the coil locations and orientations and the theoretical error values for electric and magnetic fields between the neuronavigated and 3D scanned coil positions were calculated. In addition, the sensitivity of the coil location on landmark accuracy was calculated.Main results.The measured distances between the neuronavigated and 3D scanned coil locations were on average 10.2 mm, ranging from 3.1 to 18.7 mm. The error in angles were on average from two to three degrees. The coil misplacement caused on average a 29% relative error in the electric field with a range from 9% to 51%. In the magnetic field, the same error was on average 33%, ranging from 10% to 58%. The misplacement of landmark points could cause a 1.8-fold error for the coil location.Significance.TMS neuronavigation with three landmark points can cause a significant error in the coil position, hampering research using highly accurate electric field calculations. Including 3D scanning to the process provides an efficient method to achieve a more accurate coil position.


Assuntos
Campos Magnéticos , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Reprodutibilidade dos Testes , Eletricidade , Voluntários Saudáveis
13.
Phys Med Biol ; 69(8)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38452383

RESUMO

Objective. The aim of this work is to investigate the response of the Roos chamber (type 34001) irradiated by clinical proton beams in magnetic fields.Approach. At first, a Fano test was implemented in Monte Carlo software package GATE version 9.2 (based on Geant4 version 11.0.2) using a cylindrical slab geometry in a magnetic field up to 1 T. In accordance to an experimental setup (Fuchset al2021), the magnetic field correction factorskQB⃗of the Roos chamber were determined at different energies up to 252 MeV and magnetic field strengths up to 1 T, by separately simulating the ratios of chamber signalsMQ/MQB⃗,without and with magnetic field, and the dose-conversion factorsDw,QB⃗/Dw,Qin a small cylinder of water, with and without magnetic field. Additionally, detailed simulations were carried out to understand the observed magnetic field dependence.Main results. The Fano test was passed with deviations smaller than 0.25% between 0 and 1 T. The ratios of the chamber signals show both energy and magnetic field dependence. The maximum deviation of the dose-conversion factors from unity of 0.22% was observed at the lowest investigated proton energy of 97.4 MeV andB⃗= 1 T. The resultingkQB⃗factors increase initially with the applied magnetic field and decrease again after reaching a maximum at around 0.5 T; except for the lowest 97.4 MeV beam that show no observable magnetic field dependence. The deviation from unity of the factors is also larger for higher proton energies, where the maximum lies at 1.0035(5), 1.0054(7) and 1.0069(7) for initial energies ofE0= 152, 223.4 and 252 MeV, respectively.Significance. Detailed Monte Carlo studies showed that the observed effect can be mainly attributed to the differences in the transport of electrons produced both outside and inside of the air cavity in the presence of a magnetic field.


Assuntos
Terapia com Prótons , Prótons , Radiometria/métodos , Terapia com Prótons/métodos , Campos Magnéticos , Método de Monte Carlo
14.
ACS Nano ; 18(12): 8694-8705, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38466230

RESUMO

Small-scale magnetic robots with fixed magnetizations have limited locomotion modes, restricting their applications in complex environments in vivo. Here we present a morphology-reconfigurable millirobot that can switch the locomotion modes locally by reprogramming its magnetizations during navigation, in response to distinct magnetic field patterns. By continuously switching its locomotion modes between the high-velocity rigid motion and high-adaptability soft actuation, the millirobot efficiently navigates in small lumens with intricate internal structures and complex surface topographies. As demonstrations, the millirobot performs multimodal locomotion including woodlouse-like rolling and flipping, sperm-like rotating, and snake-like gliding to negotiate different terrains, including the unrestricted channel and high platform, narrow channel, and solid-liquid interface, respectively. Finally, we demonstrate the drug delivery capability of the millirobot through the oviduct-mimicking phantom and ex vivo oviduct. The magnetization reprogramming strategy during navigation represents a promising approach for developing self-adaptive robots for performing complex tasks in vivo.


Assuntos
Oviductos , Sêmen , Masculino , Feminino , Humanos , Animais , Movimento (Física) , Sistemas de Liberação de Medicamentos , Campos Magnéticos
15.
Sci Rep ; 14(1): 7000, 2024 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-38523150

RESUMO

There is considerable interest in developing anti-glioma nanoplatforms. They make the all-in-one combination of therapies possible. Here we show how the selective Glioblastoma multiforme (GBM) cell killing of the here-established nanoplatforms increased after each coating and how the here-established vibration-inducing Alternating magnetic field (AMF) decreased the treatment time from 72 h to 30 s. Thanks to their magnetite core, these nanoplatforms can be guided to the tumor's specific site by a Fixed magnetic field, they bypass the Blood-Brain Barrier (BBB) and accumulate at the tumor site thanks to the RVG29 bonding to the G-protein on the ion-gated channel receptor known as the nicotinic acetylcholine receptor (nAchR), which expresses on BBB cells and overexpresses on GBM cells, and thanks to the positive charge gained by both chitosan and RVG29's peptide. Both ZIF-8 and its mediate adherence, Chitosan increases the drug loading capacity that stimuli response to the tumor's acidic environment. The Zn2+ ions generated from ZIF-8 sustained degradation in such an environment kill the GBM cells. Dynamic Light Scattering (DLS) evaluated these nanoplatform's mean size 155 nm indicating their almost optimum size for brain applications. Based on their elements' intrinsic properties, these nanoplatforms can enhance and combine other adjuvant therapies.


Assuntos
Quitosana , Glioblastoma , Glioma , Humanos , Quitosana/metabolismo , Glioma/metabolismo , Encéfalo/metabolismo , Barreira Hematoencefálica/metabolismo , Glioblastoma/terapia , Glioblastoma/metabolismo , Campos Magnéticos , Linhagem Celular Tumoral
16.
Sci Rep ; 14(1): 5792, 2024 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-38461218

RESUMO

Cisplatin is a chemotherapy drug widely used in cancer treatment. Alongside its clinical benefits, however, it may inflict intolerable toxicity and other adverse effects on healthy tissues. Due to the limitation of administering a high dose of cisplatin as well as cancer drug resistance, it is necessary to utilize new methods optimizing treatment modalities through both higher therapeutic efficacy and reduced administered doses of radiation and drugs. In this study, sensitive (A2780) and resistant (A2780CP) ovarian carcinoma cells underwent treatment with cisplatin + static magnetic field (SMF). First, the levels of genotoxicity after treatment were evaluated by Comet assay. Then, cell cycle analysis and apoptosis assay were conducted by a flow cytometer. Lastly, the expression levels of genes involved in apoptosis and cellular drug uptake were investigated by PCR. After treating different groups of cells for 24, 48, and 96 h, the co-treatment of SMF and cisplatin as a combination managed to increase the amount of DNA damage in both sensitive and resistant cell lines. A considerable increase in mortality of cells was also observed mostly in the form of apoptosis, which was caused by inhibition of the cell cycle. The combination also increased the expression levels of apoptotic genes, namely P53 and P21; however, it did not have much effect on the expression levels of BCL2. Besides, the levels of CTR1 gene expression increased significantly in the groups receiving the aforementioned combination. Our study suggests that the combination of cisplatin + SMF might have clinical potential which needs further investigations through future studies.


Assuntos
Antineoplásicos , Neoplasias Ovarianas , Humanos , Feminino , Cisplatino/farmacologia , Cisplatino/uso terapêutico , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Neoplasias Ovarianas/patologia , Linhagem Celular Tumoral , Resistencia a Medicamentos Antineoplásicos/genética , Apoptose , Dano ao DNA , Campos Magnéticos
17.
Nat Commun ; 15(1): 2160, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38461256

RESUMO

Rotating magnetic fields enable biomedical microrobots to overcome physiological barriers and promote extravasation and accumulation in tumors. Nevertheless, targeting deeply situated tumors requires suppression of off-target actuation in healthy tissue. Here, we investigate a control strategy for applying spatially selective torque density to microrobots by combining rotating fields with magnetostatic selection fields. Taking magnetotactic bacteria as diffuse torque-based actuators, we numerically model off-target torque suppression, indicating the feasibility of centimeter to millimeter resolution for human applications. We study focal torque application in vitro, observing off-target suppression of actuation-dependent effects such as colonization of bacteria in tumor spheroids. We then design and construct a mouse-scale torque-focusing apparatus capable of maneuvering the focal point. Applying this system to a mouse tumor model increased accumulation of intravenously injected bacteria within tumors receiving focused actuation compared to non-actuated or globally actuated groups. This control scheme combines the advantages of torque-based actuation with spatial targeting.


Assuntos
Magnetismo , Neoplasias , Animais , Humanos , Camundongos , Torque , Fenômenos Físicos , Campos Magnéticos , Bactérias
18.
Nanotheranostics ; 8(2): 163-178, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38444740

RESUMO

Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted thermometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object transfer from one system to another. Here, we present the design, development and evaluation process for integrable MFH platforms, which extends a commercial MPI scanner with the functionality of MFH. Methods: The biggest issue of integrating magnetic fluid hyperthermia platforms into a magnetic particle imaging system is the magnetic coupling of the devices, which induces high voltage in the imaging system, and is harming its components. In this paper, we use a self-compensation approach derived from heuristic algorithms to protect the magnetic particle imaging scanner. The integrable platforms are evaluated regarding electrical and magnetic characteristics, cooling capability, field strength, the magnetic coupling to a replica of the magnetic particle imaging system's main solenoid and particle heating. Results: The MFH platforms generate suitable magnetic fields for the magnetic heating of particles and are compatible with a commercial magnetic particle imaging scanner. In combination with the imaging system, selective heating with a gradient field and steerable heating positioning using the MPI focus fields are possible. Conclusion: The proposed MFH platforms serve as a therapeutic tool to unlock the MFH functionality of a commercial magnetic particle imaging scanner, enabling its use in future preclinical trials of MPI-guided, spatially selective magnetic hyperthermia therapy.


Assuntos
Hipertermia Induzida , Campos Magnéticos
19.
Proc Biol Sci ; 291(2016): 20232308, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38320616

RESUMO

Migratory birds possess remarkable accuracy in orientation and navigation, which involves various compass systems including the magnetic compass. Identifying the primary magnetosensor remains a fundamental open question. Cryptochromes (Cry) have been shown to be magnetically sensitive, and Cry4a from a migratory songbird seems to show enhanced magnetic sensitivity in vitro compared to Cry4a from resident species. We investigate Cry and their potential involvement in magnetoreception in a phylogenetic framework, integrating molecular evolutionary analyses with protein dynamics modelling. Our analysis is based on 363 bird genomes and identifies different selection regimes in passerines. We show that Cry4a is characterized by strong positive selection and high variability, typical characteristics of sensor proteins. We identify key sites that are likely to have facilitated the evolution of an optimized sensory protein for night-time orientation in songbirds. Additionally, we show that Cry4 was lost in hummingbirds, parrots and Tyranni (Suboscines), and thus identified a gene deletion, which might facilitate testing the function of Cry4a in birds. In contrast, the other avian Cry (Cry1 and Cry2) were highly conserved across all species, indicating basal, non-sensory functions. Our results support a specialization or functional differentiation of Cry4 in songbirds which could be magnetosensation.


Assuntos
Aves Canoras , Animais , Filogenia , Aves Canoras/fisiologia , Criptocromos/metabolismo , Campos Magnéticos , Migração Animal/fisiologia
20.
PLoS One ; 19(2): e0292737, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38324619

RESUMO

The transition towards renewable energy sources necessitates efficient energy storage systems to meet growing demands. Electrochemical capacitors, particularly electric double-layer capacitors (EDLCs), show promising performance due to their superior properties. However, the presence of resistance limits their performance. This study explores using an external magnetic field to mitigate ion transfer resistance and enhance capacitance in magnetite-reduced graphene oxide (M-rGO) nanocomposites. M-rGO nanocomposites with varying weight ratios of magnetite were synthesized and comprehensively characterized. Characterization highlighted the difference in certain parameters such as C/O ratio, the Id/Ig ratio, surface area and particle size that contribute towards alteration of M-rGO's capacitive behaviour. Electrochemical studies demonstrated that applying a magnetic field increased specific capacitance by approximately 20% and reduced resistance by 33%. Notably, a maximum specific capacitance of 16.36 F/g (at a scan rate of 0.1 V/s) and 27.24 F/g (at a current density of 0.25 A/g) was achieved. These improvements were attributed to enhanced ion transportation and migration at the electrode/electrolyte interface, lowering overall resistance. However, it was also observed that the aforementioned parameters can also limit the M-rGO's performance, resulting in saturated capacitive state despite a reduced resistance. The integration of magnetic fields enhances energy storage in nanocomposite systems, necessitating further investigation into underlying mechanisms and practical applications.


Assuntos
Óxido Ferroso-Férrico , Grafite , Nanocompostos , Capacitância Elétrica , Campos Magnéticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...