Influência da aspiração endotraqueal por sistema aberto e fechado nos sinais vitais de recém-nascidos submetidos à ventilação mecânica invasiva / The effect of open and closed endotracheal suctioning system on vital signs of newborns on invasive mechanical ventilation
Anjos, Elizabete Souza dos; Oliveira, Ana Claudia Tomazetti de.
Affiliation
  • Anjos, Elizabete Souza dos; Centro Universitário Lusíadas. Santos, SP. BR
  • Oliveira, Ana Claudia Tomazetti de; Centro Universitário Lusíadas. Santos, SP. BR
Rev. Soc. Bras. Clín. Méd ; 15(2): 103-108, 20170000. ilus, tab
Article in Portuguese | LILACS | ID: biblio-875553
Responsible library: BR1610.9
RESUMO

OBJETIVO:

Comparar o sistema de aspiração aberto e o fechado em relação às variações nos sinais vitais no neonato e verificar o recurso mais adequado para esta população, de acordo com seus efeitos e as características do paciente.

MÉTODOS:

Ensaio clínico crossover randomizado com sete pacientes com idade gestacional média de 20 dias. Realizaram-se os dois métodos de aspiração endotraqueal no mesmo recém-nascido, com intervalo de 24 horas, sendo a ordem da aplicação escolhida de forma aleatória. O procedimento foi avaliado em três períodos 5 minutos antes da aspiração (P1), durante a aspiração - depois de duas aspirações (P2) e após 5 minutos do procedimento (P3).

RESULTADOS:

Na frequência respiratória, houve significância entre os tipos de aspiração endotraqueal, tendo o sistema de aspiração aberto apresentado maior variação; na análise isolada dos sistemas, o sistema de aspiração aberto apresentou significância com aumento nos momentos de P1 para P2, e com diminuição de P2 para P3. Na saturação do oxigênio, houve significância na análise isolada dos sistemas, com diminuição de P1 para P2, e com aumento de P2 para P3 no sistema de aspiração aberto. Ambas as alterações encontravam-se dentro dos padrões fisiológicos aceitáveis.

CONCLUSÃO:

Sob circunstâncias rigidamente controladas em pacientes hemodinamicamente e clinicamente estáveis, tanto o sistema de aspiração aberto como o fechado podem ser utilizados, desde que a casuística seja semelhante ao estudo apresentado.(AU)
ABSTRACT

OBJECTIVE:

To compare the open and closed suctioning systems regarding changes in vital signs in the neonate, and thus to check the most appropriate resource for this population, according to its effects, and the patient's characteristics.

METHODS:

This is a crossover randomized clinical trial with seven patients with mean gestational age of 20 days. The two endotracheal suction methods were performed in the same newborn with an interval of 24 hours, with the order of application being chosen randomly. The procedure was performed in three periods five minutes before the suction (P1), during endotracheal suctioning - after two suctions (P2), after five minutes of the procedure (P3).

RESULTS:

Regarding the respiratory rate, there was significant difference between the types of endotracheal suctioning, with the open suctioning system presenting greater variation; in an isolated analysis of the systems, the open suctioning system was statistically significant with an increase in times of P1 to P2, and decrease of P2 to P3. Regarding oxygen saturation, there was significance in isolated analysis of the systems, with a reduction of P1 to P2, and increase of P2 to P3 in the open suctioning system. Both changes were within acceptable physiological patterns.

CONCLUSION:

Under strictly controlled conditions, with hemodynamically and clinically stable patients, both the open and closed suctioning systems may be used, provided that the sample is similar to the study presented.(AU)
Subject(s)

Full text: Available Collection: International databases Database: LILACS Main subject: Respiration, Artificial / Suction / Intubation, Intratracheal Type of study: Controlled clinical trial / Diagnostic study Limits: Female / Humans / Male / Infant, Newborn Language: Portuguese Journal: Rev. Soc. Bras. Clín. Méd Journal subject: Therapeutics Year: 2017 Document type: Article Affiliation country: Brazil Institution/Affiliation country: Centro Universitário Lusíadas/BR
Full text: Available Collection: International databases Database: LILACS Main subject: Respiration, Artificial / Suction / Intubation, Intratracheal Type of study: Controlled clinical trial / Diagnostic study Limits: Female / Humans / Male / Infant, Newborn Language: Portuguese Journal: Rev. Soc. Bras. Clín. Méd Journal subject: Therapeutics Year: 2017 Document type: Article Affiliation country: Brazil Institution/Affiliation country: Centro Universitário Lusíadas/BR
...