Your browser doesn't support javascript.
loading
Avaliação da higiene oral em prótese fixa múltipla sobre implantes expostos após necrose óssea ­ relato de caso / Evaluation of oral hygiene in multiple fixed prostheses on implants exposed after bone necrosis ­ case report
Barbosa, Tiago Augusto Quirino; Zancope, Karla; Karam, Frederick Khalil; Reis, Taís Alves dos; Neves, Flávio Domingues das.
Afiliação
  • Barbosa, Tiago Augusto Quirino; s.af
  • Zancope, Karla; Universidade Federal de Uberlândia. Uberlândia. BR
  • Karam, Frederick Khalil; Universidade de Rio Verde. Rio Verde. BR
  • Reis, Taís Alves dos; s.af
  • Neves, Flávio Domingues das; Universidade Federal de Uberlândia. Uberlândia. BR
Prosthes. Esthet. Sci ; 7(28): 55-60, jul-set 2018. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-946448
Biblioteca responsável: BR510.1
RESUMO
Alguns pacientes podem apresentar dificuldades motoras que inviabilizam a adequada higienização de próteses implantossuportadas. No entanto, a utilização de escovas elétricas pode compensar essas dificuldades e melhorar a qualidade de higiene oral. O presente trabalho relata um caso clínico que utilizou escova dental elétrica Philips Sonicar e AirFloss Ultra® como meio de higienização da área de implante osseointegrado exposta pós necrose óssea. Paciente dirigiu-se a um serviço de reabilitação oral com desconforto em prótese implantada ferulizada de três elementos localizada no arco inferior direito. Após análise clínica e diagnóstico, o paciente foi orientado quanto as etapas do tratamento, assim como a necessidade da manutenção dos tecidos peri-implantares através de uma correta higienização. Após um ano é possível verificar uma condição satisfatória da região avaliada e maior satisfação do paciente quanto ao método de limpeza empregado. (AU).
ABSTRACT
Some patients may present motor difficulties that prevent the adequate hygiene of implanted prosthesis. However, the use of electric toothbrushes can compensate these difficulties and improve the quality of oral hygiene. The present study reported the case of a patient who used Philips Sonicar electric brush and AirFloss Ultra® to clean an osseointegrated implant area exposed after bone necrosis. Patient went to an oral rehabilitation service with discomfort in a three-element splinted implanted prosthesis area, located in the lower right arch. After clinical analysis and diagnosis, the patient was advised on the steps of treatment as well as the necessity of the maintenance of the peri-implant tissues with a correct oral hygiene. After one year, it is still possible to verify a satisfactory condition of the evaluated region and greater satisfaction of the patient regarding the cleaning method employed. (AU).
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Higiene Bucal / Qualidade de Vida / Prótese Dentária Fixada por Implante Aspecto: Preferência do paciente Limite: Adulto / Humanos / Masculino Idioma: Português Revista: Prosthes. Esthet. Sci Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Universidade Federal de Uberlândia/BR / Universidade de Rio Verde/BR
Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Higiene Bucal / Qualidade de Vida / Prótese Dentária Fixada por Implante Aspecto: Preferência do paciente Limite: Adulto / Humanos / Masculino Idioma: Português Revista: Prosthes. Esthet. Sci Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Universidade Federal de Uberlândia/BR / Universidade de Rio Verde/BR
...