Your browser doesn't support javascript.
loading
Sensibilidad y especificidad de la tomografía axial computarizada para el diagnóstico de hemorragia de vías digestivas: metaanálisis / Sensitivity and Specificity of Computer Tomography in the Diagnostic of Gastrointestinal Bleeding: Meta-Analysis
Hernández, Jairo; Mora, Carolina; Cobeñas, Ricardo; Cruz Gallo, Juan.
Afiliação
  • Hernández, Jairo; Universidad de los Andes. CL
  • Mora, Carolina; Centro de Educación Médica e Investigaciones Clínicas (CEMIC), Departamento de Imágenes Diagnósticas. AR
  • Cobeñas, Ricardo; Centro de Educación Médica e Investigaciones Clínicas (CEMIC), Departamento de Imágenes Diagnósticas. AR
  • Cruz Gallo, Juan; Centro de Educación Médica e Investigaciones Clínicas (CEMIC), Departamento de Imágenes Diagnósticas. AR
Rev. colomb. radiol ; 26(2): 4178-4185, 2015. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: biblio-988034
Biblioteca responsável: CO371.9
RESUMEN

Objetivo:

Hacer un metaanálisis mediante una revisión sistemática de la literatura, de los estudios de diagnóstico con mayor calidad metodológica según el quality assessment tool for diagnostic accuracy studies (QUADAS-1).

Métodos:

Se evaluó la eficacia diagnóstica de la TC para HVD en comparación con la angiografía, la endoscopia, la colonoscopia, el seguimiento médico, la cirugía, los procedimientos de medicina nuclear o la combinación de cualquiera de estos métodos; se realizó una búsqueda sistemática de la información de enero de 1998 a agosto de 2013 en PubMed, National Guideline Clearinghouse, Canadian Medical Association Infobase, The Cochrane Library y en el Database of Abstracts of Reviews of Effectiveness (DARE), de artículos que evaluaran la TC en comparación con los procedimientos mencionados anteriormente; se escogieron 13 artículos con calidad metodológica adecuada de acuerdo al QUADAS-1 (mayor de 6), en los cuales se evaluó la heterogeneidad y, posteriormente, de acuerdo con estos resultados, se realizó el análisis estadístico.

Resultados:

Las medias combinadas de los 13 estudios son las siguientes Sensibilidad 88 %, especificidad 96 %, valor predictivo positivo 22,5, valor predictivo negativo 0,12, Diagnostic Odds Ratio 182 y área bajo la curva 0,91.

Conclusión:

Los resultados indican que la TC presenta una buena exactitud diagnóstica, por lo que se puede concluir que la TC es una modalidad con alto rendimiento en el diagnóstico de HVD.

Summary:

ABSTRACT

Objective:

To perform a meta-analysis through a systematic review of the literature, of the diagnosis studies with higher methodological quality according to the quality assessment tool for diagnostic accuracy studies (QUADAS-1).

Methods:

We evaluated the diagnostic efficacy of CT for gastrointestinal bleeding compared with angiography, endoscopy, colonoscopy, medical assessment, surgery, nuclear medicine procedures, or a combination of any of these methods; A systematic review was made from January 1998 to August 2013-in PubMed, National Guideline Clearinghouse, Canadian Medical Association Infobase, The Cochrane Library and the Database of Abstracts of Reviews of Effectiveness (DARE)-of papers that assessing the CT compared to the above procedures, 13 articles with adequate methodological quality according to QUADAS-1 (more than 6) were chosen, in which the heterogeneity results were evaluated and according to it, the statistical analysis was performed.

Results:

The combined average of the 13 studies is the following sensitivity 88%, specificity 96%, positive predictive value 22.5, negative predictive value 0.12, Diagnostic Odds Ratio 182 and AUC 0.91.

Conclusions:

The results indicate that CT has a good diagnostic accuracy with which we can conclude that CT is a modality with high performance in the diagnosis of gastrointestinal bleeding.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Tomografia Computadorizada por Raios X Tipo de estudo: Estudo diagnóstico / Guia de prática clínica / Estudo prognóstico / Revisão sistemática Limite: Humanos Idioma: Espanhol Revista: Rev. colomb. radiol Assunto da revista: Radiologia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Argentina / Chile Instituição/País de afiliação: Centro de Educación Médica e Investigaciones Clínicas (CEMIC), Departamento de Imágenes Diagnósticas/AR / Universidad de los Andes/CL
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Tomografia Computadorizada por Raios X Tipo de estudo: Estudo diagnóstico / Guia de prática clínica / Estudo prognóstico / Revisão sistemática Limite: Humanos Idioma: Espanhol Revista: Rev. colomb. radiol Assunto da revista: Radiologia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Argentina / Chile Instituição/País de afiliação: Centro de Educación Médica e Investigaciones Clínicas (CEMIC), Departamento de Imágenes Diagnósticas/AR / Universidad de los Andes/CL
...