Sistema de Informações Hospitalares do Sistema Único de Saúde (SIH-SUS): uma avaliação do seu desempenho para a identificação do near miss materno / /The Hospital Information System of the Brazilian Unified National Health System: a performance evaluation for auditing maternal near miss / /Sistema de Información Hospitalaria del Sistema Único de Salud (SIH-SUS): una evaluación de su rendimiento para la identificación de near miss materno
Nakamura-Pereira, Marcos; Mendes-Silva, Wallace; Dias, Marcos Augusto Bastos; Reichenheim, Michael E; Lobato, Gustavo.
Afiliação
  • Nakamura-Pereira, Marcos; Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Rio de Janeiro. Brasil
  • Mendes-Silva, Wallace; Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Rio de Janeiro. Brasil
  • Dias, Marcos Augusto Bastos; Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Rio de Janeiro. Brasil
  • Reichenheim, Michael E; Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Rio de Janeiro. Brasil
  • Lobato, Gustavo; Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Rio de Janeiro. Brasil
Cad. saúde pública ; 29(7): 1333-1345, Jul. 2013. ilus, tab
Artigo em Português | ENSP, FIOCRUZ | ID: ens-30849
Biblioteca responsável: BR526.1
RESUMO
Este estudo avaliou o desempenho do Sistema de Informações Hospitalares do Sistema Único de Saúde (SIH-SUS) na identificação de casos de near miss materno ocorridos em hospital do Rio de Janeiro, em 2008. Os casos foram captados pela revisão de todos os prontuários médicos de gestantes ou puérperas internadas na unidade, e a busca por potenciais eventos de near miss na base do SIH-SUS valeu-se de uma lista de procedimentos e códigos da Classificação Internacional de Doenças, 10ª revisão (CID-10), que fossem compatíveis com esse diagnóstico. A revisão de prontuários identificou 27 casos, enquanto na base do SIH-SUS encontrou-se 70 possíveis ocorrências de near miss. Porém, dessas 70 apenas cinco efetivamente eram casos near miss conforme os prontuários, correspondendo então à sensibilidade de 18,5% (IC95% 6,3-38,1), especificidade de 94,3% (IC95% 92,8-95,6), área sob a curva ROC de 0,56 (IC95% 0,48-0,63) e valor preditivo positivo de 10,1% (IC95% 4,7-20,3). Esses achados sugerem que o SIH-SUS não é adequado para o monitoramento dos casos de near miss materno.(AU)
ABSTRACT
This study aimed to investigate the performance of the Hospital Information System of the Brazilian Unified National Health System (SIH-SUS) in identifying cases of maternal near miss in a hospital in Rio de Janeiro, Brazil, in 2008. Cases were identified by reviewing medical records of pregnant and postpartum women admitted to the hospital. The search for potential near miss events in the SIH-SUS database relied on a list of procedures and codes from the International Classification of Diseases, 10th revision (ICD-10) that were consistent with this diagnosis. The patient chart review identified 27 cases, while 70 potential occurrences of near miss were detected in the SIH-SUS database. However, only 5 of 70 were "true cases" of near miss according to the chart review, which corresponds to a sensitivity of 18.5% (95%CI 6.3-38.1), specificity of 94.3% (95%CI 92.8-95.6), area under the ROC of 0.56 (95%CI 0.48-0.63), and positive predictive value of 10.1% (IC95% 4.7-20.3). These findings suggest that SIH-SUS does not appear appropriate for monitoring maternal near miss.(AU)
RESUMEN
Este estudio evaluó el desempeño del Sistema de Información Hospitalaria del Sistema Único de Salud (SIH-SUS) en la identificación de casos de near miss materno en un hospital de Río de Janeiro en 2008. Los casos se obtuvieron mediante revisión de los historiales clínicos de las embarazadas y puérperas ingresadas en la unidad, y la búsqueda de posibles eventos near miss en la base del SIH-SUS se basó en una lista de procedimientos y códigos de la Clasificación Internacional de Enfermedades (CIE-10) que son compatibles con este diagnóstico. Una revisión retrospectiva de historiales clínicos identificó 27 casos, mientras que la base de la SIH-SUS localizó 70 posibles casos con este diagnóstico. Sin embargo, sólo cinco de los 70 casos fueron en realidad casos de near miss, por ello, la sensibilidad correspondiente fue de un 18,5% (IC95% 6,3-38,1), una especificidad del 94,3% (IC95% 92,8-95,6), el área bajo la curva ROC de un 0,56 (IC95% 0,48-0,63) y el valor predictivo positivo de un 10,1% (IC95% 4,7-20,3). Estos hallazgos sugieren que SIH-SUS no es adecuado para el seguimiento de near miss.(AU)
Assuntos


Texto completo: Disponível Base de dados: ENSP / FIOCRUZ Assunto principal: Complicações na Gravidez / Mortalidade Materna / Sistemas de Informação Hospitalar / Programas Nacionais de Saúde Limite: Adolescente / Adulto / Feminino / Humanos / Gravidez País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Cad. saúde pública Ano de publicação: 2013 Tipo de documento: Artigo / Documento de projeto Instituição/País de afiliação: Fundação Oswaldo Cruz/Brasil

Texto completo: Disponível Base de dados: ENSP / FIOCRUZ Assunto principal: Complicações na Gravidez / Mortalidade Materna / Sistemas de Informação Hospitalar / Programas Nacionais de Saúde Limite: Adolescente / Adulto / Feminino / Humanos / Gravidez País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Cad. saúde pública Ano de publicação: 2013 Tipo de documento: Artigo / Documento de projeto Instituição/País de afiliação: Fundação Oswaldo Cruz/Brasil
...