Your browser doesn't support javascript.
loading
La tomografía por emisión de positrones-tomografía computarizada con 18F-fluordesoxiglucosa en los pacientes con cáncer diferenciado de tiroides en recurrencia y rastreo con radioyodo negativo. Rendimiento diagnóstico y relación con los niveles de tiroglobulina / Positron emission tomography-computed tomography with 18F-fluorodeoxyglucose in patients with recurrent differentiated thyroid carcinoma and negative radioiodine scan. Diagnostic performance and relation with tyroglobulin levels
Mariscal Labrador, E; García Burillo, A; Castell-Conesa, J; Obiols Alfonso, G; Kisiel González, N; Barios Profitós, M; Aguadé-Bruix, S; Mesa Manteca, J.
Afiliação
  • Mariscal Labrador, E; Universitat Autònoma de Barcelona. Hospital Universitari Vall d’Hebron. Barcelona. España
  • García Burillo, A; Universitat Autònoma de Barcelona. Hospital Universitari Vall d’Hebron. Barcelona. España
  • Castell-Conesa, J; Universitat Autònoma de Barcelona. Hospital Universitari Vall d’Hebron. Barcelona. España
  • Obiols Alfonso, G; Universitat Autònoma de Barcelona. Hospital Universitari Vall d’Hebron. Barcelona. España
  • Kisiel González, N; Universitat Autònoma de Barcelona. Hospital Universitari Vall d’Hebron. Barcelona. España
  • Barios Profitós, M; Universitat Autònoma de Barcelona. Hospital Universitari Vall d’Hebron. Barcelona. España
  • Aguadé-Bruix, S; Universitat Autònoma de Barcelona. Hospital Universitari Vall d’Hebron. Barcelona. España
  • Mesa Manteca, J; Universitat Autònoma de Barcelona. Hospital Universitari Vall d’Hebron. Barcelona. España
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 32(3): 146-151, mayo-jun. 2013.
Artigo em Espanhol | IBECS | ID: ibc-112562
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Objetivo. Evaluar el rendimiento diagnóstico de la PET-TC con 18F-FDG y su relación con los niveles séricos de tiroglobulina (Tg) en los pacientes con cáncer diferenciado de tiroides con sospecha de persistencia o recurrencia de enfermedad y rastreo con radioyodo negativo. Material y métodos. Análisis retrospectivo de 35 estudios PET-TC en 25 pacientes (17 mujeres, edad media 48,8±15,2 años). Los resultados se comprobaron histológicamente, o mediante ecografía y seguimiento clínico. Se analizó la relación entre el rendimiento diagnóstico de la PET-TC y 3 niveles de Tg ≤2ng/ml; entre 2 y 10 ng/ml, y >10ng/ml. Resultados. Se obtuvieron 26 verdaderos positivos, un falso positivo, 3 verdaderos negativos y 5 falsos negativos. De los 18 pacientes con una PET-TC clasificada como verdadero positivo, 3 mostraron lesiones en el lecho postiroidectomía, 15 mostraron afectación ganglionar y 5 presentaron metástasis a distancia. La sensibilidad fue del 83,9% (IC95% 69,3-98,4%) y la especificidad del 75% (IC95% 20-100%). Para 3 intervalos de Tg, la PET-TC mostró una tasa de verdaderos positivos del 37,5, del 83 y del 100% en los pacientes con niveles de Tg <2, entre 2 y 10, y >10 ng/ml, respectivamente. Conclusiones. La PET-TC con 18F-FDG muestra un alto rendimiento diagnóstico de la enfermedad locorregional y a distancia en la población de pacientes con cáncer diferenciado de tiroides en situación de persistencia de enfermedad y rastreo con yodo negativo con niveles de Tg >2ng/ml(AU)
ABSTRACT
Objective. To assess the diagnostic performance of 18F-FDG PET-CT scan and its relation to serum thyroglobulin (Tg) levels in patients with differentiated thyroid carcinoma with suspicion of persistence or recurrence of the disease and negative radioiodine scans. Materials and methods. This is a retrospective analysis of 35 PET-CT studies in 25 patients (17 women, average age 48.8±15.2 years). The results were confirmed by histology or by ultrasonography and clinical follow-up. We analyzed the relationship between the diagnostic performance of the PET-CT scans and three levels of Tg ≤2ng/ml; between 2 and 10 ng/ml, and >10ng/ml. Results. We obtained 26 true-positives (TP), one false-positive (FP), 3 true-negatives (TN) and 5 false-negatives (FN). Of the 18 patients with PET-CTs classified as TP, 3 showed lesions at the post-thyroidectomy bed, 15 showed lymph node metastases and 5 were distant metastases. Sensitivity was 83.9% (95%CI 69.3%-98.4%) and specificity was 75% (95%CI 20%-100%). Regarding the three intervals of Tg, PET-CT scan showed TP rates of 37.5%, 83% and 100% in patients with Tg levels <2ng/ml, between 2 and 10ng/ml, and >10ng/ml, respectively. Conclusions. 18F-FDG PET-CT demonstrates high diagnostic yield in local disease and distant lesions for the population of patients with differentiated thyroid carcinoma and persistence of the disease with negative radioiodine scans at Tg levels above 2ng/ml(AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Tireoglobulina / Neoplasias da Glândula Tireoide / Sensibilidade e Especificidade / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo de rastreamento Limite: Adulto / Feminino / Humanos Idioma: Espanhol Revista: Rev. esp. med. nucl. imagen mol. (Ed. impr.) Ano de publicação: 2013 Tipo de documento: Artigo Instituição/País de afiliação: Universitat Autònoma de Barcelona/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Tireoglobulina / Neoplasias da Glândula Tireoide / Sensibilidade e Especificidade / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo de rastreamento Limite: Adulto / Feminino / Humanos Idioma: Espanhol Revista: Rev. esp. med. nucl. imagen mol. (Ed. impr.) Ano de publicação: 2013 Tipo de documento: Artigo Instituição/País de afiliação: Universitat Autònoma de Barcelona/España
...