Your browser doesn't support javascript.
loading
Defectos de perfusión en el mapa de iodo pulmonar: causas y semiología / Perfusion defects in pulmonary perfusion iodine maps: causes and semiology
Bustos Fiore, A; González Vázquez, M; Trinidad López, C; Mera Fernández, D; Costas Álvarez, M.
Afiliação
  • Bustos Fiore, A; Hospital POVISA. Servicio de Radiodiagnóstico. Vigo. España
  • González Vázquez, M; Hospital POVISA. Servicio de Radiodiagnóstico. Vigo. España
  • Trinidad López, C; Hospital POVISA. Servicio de Radiodiagnóstico. Vigo. España
  • Mera Fernández, D; Hospital POVISA. Servicio de Radiodiagnóstico. Vigo. España
  • Costas Álvarez, M; Hospital POVISA. Servicio de Radiodiagnóstico. Vigo. España
Radiología (Madr., Ed. impr.) ; 60(4): 301-309, jul.-ago. 2018. ilus
Artigo em Espanhol | IBECS | ID: ibc-175254
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Describir la utilidad de la tomografía computarizada con energía dual (TCED) en la obtención de mapas de perfusión pulmonar para aportar información morfológica y funcional en el tromboembolismo pulmonar (TEP). Revisar la semiología de los defectos de perfusión debidos a TEP y diferenciarlos de los defectos no debidos a TEP que son alteraciones que quedan fuera del rango utilizado en el mapa de iodo y están causados por otras enfermedades del parénquima pulmonar o por artefactos.

Conclusión:

La angiografía por TC de las arterias pulmonares es la técnica de elección en el diagnóstico de TEP. Las nuevas TC con energía dual son útiles para detectar defectos de perfusión secundarios a obstrucción completa o parcial de las arterias pulmonares, y tiene su mayor utilidad en la detección de TEP en ramas subsegmentarias
ABSTRACT

Objective:

to describe the usefulness of dual-energy CT for obtaining pulmonary perfusion maps to provide morphological and functional information in patients with pulmonary embolisms. To review the semiology of perfusion defects due to pulmonary embolism so they can be differentiated from perfusion defects due to other causes alterations outside the range used in the iodine map caused by other diseases of the lung parenchyma or artifacts.

Conclusion:

CT angiography of the pulmonary arteries is the technique of choice for the diagnosis of pulmonary embolisms. New dual-energy CT scanners are useful for detecting perfusion defects secondary to complete or partial obstruction of pulmonary arteries and is most useful for detecting pulmonary embolisms in subsegmental branches
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Embolia Pulmonar / Tomografia Computadorizada por Raios X / Imagem de Perfusão Tipo de estudo: Estudo de etiologia Limite: Humanos Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Hospital POVISA/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Embolia Pulmonar / Tomografia Computadorizada por Raios X / Imagem de Perfusão Tipo de estudo: Estudo de etiologia Limite: Humanos Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Hospital POVISA/España
...