Your browser doesn't support javascript.
loading
Relación entre los componentes ópticos oculares e implicaciones en el proceso de emetropización / The realtionships between ocular optical components and implication sin the process of emmetropization
Yebra-Pimentel, E; González-Méijome, JM; García-Resúa, C; Giráldez-Fernández, MJ.
Afiliação
  • Yebra-Pimentel, E; Universidad Santiago de Compostela. Escuela Universitaria de Óptica y Optometría. Santiago de Compostela. España
  • González-Méijome, JM; Universidad do Minho. Braga. Portugal
  • García-Resúa, C; Universidad Santiago de Compostela. Escuela Universitaria de Óptica y Optometría. Santiago de Compostela. España
  • Giráldez-Fernández, MJ; Universidad Santiago de Compostela. Escuela Universitaria de Óptica y Optometría. Santiago de Compostela. España
Arch. Soc. Esp. Oftalmol ; 83(5): 307-316, mayo 2008. ilus, tab
Artigo em Es | IBECS | ID: ibc-64537
Biblioteca responsável: ES15.1
Localização: ES15.1 - BNCS
RESUMEN

Objetivo:

Determinar la relación entre los diferentes componentes ópticos oculares y la emetropización en función de la longitud axial (LA).

Métodos:

Participaron 109 jóvenes universitarios divididos en cinco grupos según el error refractivo emétropes, hipermétropes, miopes bajos, miopes moderados y miopes altos. La medida de los parámetros intraoculares y el análisis de la topografía corneal se realizó mediante ultrasonografía y videoqueratoscopia respectivamente.

Resultados:

Se encontró una correlación estadísticamente significativa entre la profundidad de la cámara anterior (PCA) y la LA en ojos con LA menor de 24 mm (r = 0,441; p < 0,001). Sin embargo en ojos con LA mayor no se encontró tal relación (r = 0,098; p = 0,527). El espesor del cristalino (EC) mostró una correlación inversa con la LA para los ojos con LA < 24 mm (r = 0,391; p < 0,001), siendo nula en el caso de ojos con LA ≥ 24 mm. La curvatura corneal (RC) sólo mostró una débil correlación con la profundidad de la cámara vítrea (PCV) en ojos con LA < 24 mm (r = 0,363; p < 0,003).

Conclusión:

Los parámetros ópticos del ojo humano se relacionan de distinta forma según el tamaño del ojo, encontrándose en los ojos más miopes una ausencia de coordinación entre los componentes ópticos oculares, que según los resultados de este estudio, es a partir de 2,00 D
ABSTRACT

Purpose:

To report the relationship between different optical ocular components and the influence of axial length on emmetropization.

Methods:

109 young university students, divided into five groups, were enrolled in this study emmetropes, hyperopes, low myopes, moderate myopes and high myopes. Intraocular parameters and topographic corneal analyses were performed by ultrasonography and videokeratoscopy respectively.

Results:

Anterior chamber depth and axial length were found to correlate significantly in eyes with axial lengths less than 24 mm (r = 0.441; p < 0.001) However this correlation was not found in eyes with longer axial lengths (r = 0.098; p = 0.527). Lens thickness showed an inverse correlation with axial length for shorter eyes (r = 0.391; p < 0.001), whereas any correlation in longer eyes was associated with moderate to high levels of myopia. Anterior corneal curvature only correlated, although weakly, with vitreous chamber depth for shorter eyes (r = 0.363; p < 0.003).

Conclusion:

Differences in optical parameters of the human eye displayed different associations in longer eyes. A lack of correlation was seen between ocular components in eyes with higher myopia, corresponding to myopia in excess of 2.00 D (Arch Soc Esp Oftalmol 2008; 83 307-316)
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Erros de Refração / Estudantes / Tetracaína / Topografia da Córnea Tipo de estudo: Estudo prognóstico / Fatores de risco Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Santiago de Compostela/España / Universidad do Minho/Portugal
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Erros de Refração / Estudantes / Tetracaína / Topografia da Córnea Tipo de estudo: Estudo prognóstico / Fatores de risco Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Santiago de Compostela/España / Universidad do Minho/Portugal
...