Your browser doesn't support javascript.
loading
Relación entre la percepción de la capacidad aeróbica y el VO2máx en bomberos / Relation between the perception of the aerobic capacity and the VO2max in firemen
Prieto Saborit, José Antonio; Valle Soto, Miguel del; Montoliú Sanclement, M. Ángeles; Martínez Suárez, Pedro Carlos; Nistal Hernández, Paloma; González Díez, Vicente.
Afiliação
  • Prieto Saborit, José Antonio; Universidad de Oviedo. Oviedo. España
  • Valle Soto, Miguel del; Universidad de Oviedo. Oviedo. España
  • Montoliú Sanclement, M. Ángeles; Hospital Central de Asturias. Asturias. España
  • Martínez Suárez, Pedro Carlos; Escuela Universitaria de Enfermería de Cabueñes. España
  • Nistal Hernández, Paloma; Universidad de Oviedo. Oviedo. España
  • González Díez, Vicente; Mancomunidad Cabo Peñas. s.p
Psicothema (Oviedo) ; 22(1): 131-136, 2010. tab
Artigo em Espanhol | IBECS | ID: ibc-77229
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Para un bombero, conocer su estado de forma implica regular la intensidad del rescate sin provocar una fatiga prematura. El objetivo principal del estudio es conocer la capacidad aeróbica real (CAR) de una muestra de bomberos basada en su VO2máx y compararla con dos medidas autoinformadas la valoración subjetiva de su capacidad aeróbica (VSCA) y la valoración del ejercicio físico realizado (VEF). Participaron 37 bomberos del Principado de Asturias. Se realizaron pruebas de esfuerzo hasta la extenuación en una cinta sin fin, midiendo la frecuencia cardíaca y el consumo VO2máx. El 94,4% de los bomberos que obtuvieron un VO2máx por debajo de 43 ml/min/Kg (mínimo aconsejado para desarrollar su trabajo eficazmente) consideró su capacidad aeróbica «alta» o «muy alta». Esto podría ser influenciado por la falta de información que reciben sobre su capacidad aeróbica a causa de un entrenamiento voluntario y autoprogramado. Se aconseja planificar entrenamientos supervisados por un especialista y realizar test periódicos que informen del la capacidad aeróbica (AU)
ABSTRACT
For a fireman, knowing whether he is fit enough for his job implies regulating the intensity of the rescue without causing premature body fatigue. Therefore, the main purpose of this study is to determine the real aerobic capacity in a sample of firemen, based on the VO2máx, and to compare it with two self-report

measures:

the subjective appraisal of aerobic capacity and the appraisal of the physical exercise carried out. Thus, 37 firemen from Asturias took part in this study and performed effort tests on a treadmill, measuring their heart frequency and VO2máx consumption. Of the firemen, 94.4% who obtained a VO2máx below 43 ml/min/kg (the minimum advised to perform their job effectively) considered their aerobic capacity to be «high» or «very high». This might be influenced by the lack of feedback on their aerobic capacity, as their training is voluntary and self-planned. Therefore, it is highly recommended to program specialized training and to carry out periodical tests to provide feedback about aerobic capacity (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Ventilação Voluntária Máxima / Esforço Físico Limite: Adulto / Humanos / Masculino Idioma: Espanhol Revista: Psicothema (Oviedo) Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Escuela Universitaria de Enfermería de Cabueñes/España / Hospital Central de Asturias/España / Mancomunidad Cabo Peñas/s.p / Universidad de Oviedo/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Ventilação Voluntária Máxima / Esforço Físico Limite: Adulto / Humanos / Masculino Idioma: Espanhol Revista: Psicothema (Oviedo) Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Escuela Universitaria de Enfermería de Cabueñes/España / Hospital Central de Asturias/España / Mancomunidad Cabo Peñas/s.p / Universidad de Oviedo/España
...