Your browser doesn't support javascript.
loading
Digitizing radiographic films: a simple way to evaluate indirect digital images
Rubia-Bullen, Izabel Regina Fischer; Escarpinati, Maurício Cunha; Schiabel, Homero; Vieira, Marcelo Andrade da Costa; Rubira, Cássia Maria Fischer; Lauris, José Roberto Pereira.
Afiliação
  • Rubia-Bullen, Izabel Regina Fischer; University of São Paulo. Bauru School of Dentistry. Department of Stomatology. Bauru. BR
  • Escarpinati, Maurício Cunha; University of São Paulo. School of Electrical Engineering. São Carlos. BR
  • Schiabel, Homero; University of São Paulo. School of Electrical Engineering. São Carlos. BR
  • Vieira, Marcelo Andrade da Costa; University of São Paulo. School of Electrical Engineering. São Carlos. BR
  • Rubira, Cássia Maria Fischer; University of São Paulo. Bauru School of Dentistry. Bauru. BR
  • Lauris, José Roberto Pereira; University of São Paulo. Bauru School of Dentistry. Bauru. BR
J. appl. oral sci ; 15(1): 14-17, Jan.-Feb. 2007. tab, graf
Artigo em Inglês | LILACS | ID: lil-450004
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVES:

This study applied a simple method to evaluate the performance of three digital devices (two scanners and one digital camera) using the reproducibility of pixel values attributed to the same radiographic image.

METHODS:

Using the same capture parameters, a radiographic image was repeatedly digitized in order to determine the variability of pixel values given to the image throughout the digitization process. One coefficient value was obtained and was called pixel value reproducibility.

RESULTS:

A significant difference in pixel values was observed among the three devices for the digitized images (ANOVA, p<0.00001). There was significant pixel value variability at the same digitization conditions for one scanner and the digital camera.

CONCLUSIONS:

Digital devices may assign pixel values differently in consecutive digitization depending on the optical density of the radiographic image and the equipment. The pixel value reproducibility was not satisfactory as tested for two devices. It is maybe advisable knowing the digitization variations regarding pixel values whenever using digital radiography images in longitudinal clinical examinations.
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: University of São Paulo/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: University of São Paulo/BR
...