Your browser doesn't support javascript.
loading
Substituição da valva mitral com tração dos músculos papilares em pacientes com miocardiopatia dilatada / Mitral valve replacement with chordae tendineae preservation, traction and fixation in end-stage dilated cardiomyopathy
Gaiotto, Fabio Antonio; Puig, Luiz Boro; Mady, Charles; Fernandes, Fábio; Tossuniam, Carlos Eduardo; Pardi, Miriam Magalhães; Dallan, Luis A. O; Oliveira, Sérgio Almeida de; Ramires, José F; Pomerantzeff, Pablo M. A.
Afiliação
  • Gaiotto, Fabio Antonio; USP. FM. HC. InCor. São Paulo. BR
  • Puig, Luiz Boro; USP. FM. HC. InCor. São Paulo. BR
  • Mady, Charles; USP. FM. HC. InCor. São Paulo. BR
  • Fernandes, Fábio; USP. FM. HC. InCor. São Paulo. BR
  • Tossuniam, Carlos Eduardo; USP. FM. HC. InCor. São Paulo. BR
  • Pardi, Miriam Magalhães; USP. FM. HC. InCor. São Paulo. BR
  • Dallan, Luis A. O; USP. FM. HC. InCor. São Paulo. BR
  • Oliveira, Sérgio Almeida de; USP. FM. HC. InCor. São Paulo. BR
  • Ramires, José F; USP. FM. HC. InCor. São Paulo. BR
  • Pomerantzeff, Pablo M. A; USP. FM. HC. InCor. São Paulo. BR
Rev. bras. cir. cardiovasc ; 22(1): 68-74, jan.-mar. 2007. tab, ilus, graf
Artigo em Português | LILACS | ID: lil-454629
Biblioteca responsável: BR44.1
RESUMO

OBJETIVO:

Avaliar a geometria e a função do ventrículo esquerdo (VE) após a troca mitral com tração e fixação dos papilares, em portadores de insuficiência cardíaca terminal com insuficiência mitral secundária.

MÉTODO:

Dos 20 pacientes avaliados, 70 por cento eram homens, com idade média de 50,2 anos e 55 por cento recebiam inotrópicos. A fração de ejeção (FEVE) foi menor que 30 por cento em todos; 85 por cento estavam em classe funcional (CF) IV. Dezoito receberam próteses de pericárdio bovino e dois, mecânicas. Os períodos considerados foram 3, 6, 12 e 18 meses. As variáveis consideradas volume sistólico do VE (VS), a FEVE, os diâmetros sistólico e diastólico finais (DSF e DDF) e os volumes sistólico e diastólico finais (VSF e VDF). No estudo estatístico, empregou-se da análise de variância (AV) e o teste de Friedmann (F). A sobrevida foi aferida pelo método de Kaplan-Meyer.

RESULTADOS:

Dois (10 por cento) faleceram no período imediato. A sobrevida no primeiro ano foi de 85 por cento, no segundo, 44 por cento, no terceiro, 44 por cento, no quarto, 44 por cento e no quinto, 44 por cento. A comparação entre pré e 3 meses, empregando-se a AV, não revelou alteração significativa para o VS (p=0,086). Houve acréscimo da FEVE (p=0,008) e decréscimo do DDF (p=0,038); do DSF (p=0,008); do VDF (p=0,029) e do VSF (p=0,009). Os momentos pré, 3 e 6 meses, com o teste F, não revelaram alterações. Entre os momentos pré, 3 meses e final, empregando-se a AV, não houve significância.

CONCLUSÃO:

Há melhora da FEVE, dos VDF, VSF, DDF e DSF; até o terceiro mês. A partir de então, as variáveis permanecem estáveis.
ABSTRACT

OBJECTIVE:

This study aimed at evaluating results of mitral valve replacement using a new technique of complete chordae tendineae adjustment for left ventricular remodeling.

METHODS:

Twenty end-stage idiopathic dilated cardiomyopathy patients with severe functional mitral valve regurgitation underwent mitral valve replacement. Seventeen (85 percent) were in functional class IV. Both anterior and posterior leaflets of the mitral valve were divided to obtain 4 pillars of chordae tendineae. These were displaced with traction toward the left atrium and anchored between the mitral annulus and a valvular prosthesis. To evaluate the left ventricular remodeling, Doppler echocardiography was performed. For statistical analysis, variance analysis and the Friedman's test were employed.

RESULTS:

Two (10 percent) early deaths occurred. Kaplan-Meyer showed survival at one year post-operative was 85 percent, 2 years it was 44 percent, at 3 years 44 percent, at 4 years 44 percent and at 5 years it was 44 percent. In the 48- and 54-month follow-ups, the McNemar test showed improvement in the functional class (p<0.001). In the third month of follow-up, variance analysis showed improvement in the ejection fraction (p=0.008) and reductions of the end diastolic diameter (p=0.038), end systolic diameter (p=0.008), end systolic volume (p=0.029) and end diastolic volume (p=0.009). No statistical differences were noted in the systolic volume. Comparing pre-operative and third- and six-month follow-ups, the Friedman test showed no statistical differences for all studied variables. Variance analyses between pre, three-month and final evaluations showed no significant differences.

CONCLUSION:

This technique of mitral valve replacement improved the left ventricle ejection fraction and decreased the end diastolic and systolic diameters and the end systolic diastolic volumes up to the third month of follow-up. From then on the variables stabilized.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Meta 3.4 Reduzir as mortes prematuras devido doenças não transmissíveis Problema de saúde: Doença Cardiovascular / Outras Doenças Circulatórias Base de dados: LILACS Assunto principal: Cardiomiopatia Dilatada / Insuficiência Cardíaca / Valva Mitral Limite: Humanos Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / CIRURGIA GERAL Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: USP/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Meta 3.4 Reduzir as mortes prematuras devido doenças não transmissíveis Problema de saúde: Doença Cardiovascular / Outras Doenças Circulatórias Base de dados: LILACS Assunto principal: Cardiomiopatia Dilatada / Insuficiência Cardíaca / Valva Mitral Limite: Humanos Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / CIRURGIA GERAL Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: USP/BR
...