Your browser doesn't support javascript.
loading
Estudo comparativo entre a curva diária de pressão intra-ocular e a associação da curva ambulatorial com o teste de sobrecarga hídrica no glaucoma primário de ângulo aberto, glaucoma de pressão normal e olhos normais / Comparative study between diurnal intraocular pressure curve and the association of ambulatory intraocular pressure curve with the water-drinking test in open angle glaucoma, normal tension glaucoma and normal eyes
Meirelles, Sergio Henrique Sampaio; Yamane, Riuitiro; Álvares, Riani Morelo; Botelho, Priscilla Barbuto; Morais, Fábio Barreto; Moreira, Pedro Bertino; Dantas, Adalmir Morterá; Moraes Júnior, Haroldo Vieira de.
Afiliação
  • Meirelles, Sergio Henrique Sampaio; Universidade Gama Filho. Rio de Janeiro. BR
  • Yamane, Riuitiro; Universidade Estadual do Rio de Janeiro. Rio de Janeiro. BR
  • Álvares, Riani Morelo; Hospital Municipal da Piedade. Rio de Janeiro. BR
  • Botelho, Priscilla Barbuto; Hospital Municipal da Piedade. Rio de Janeiro. BR
  • Morais, Fábio Barreto; Hospital Municipal da Piedade. Rio de Janeiro. BR
  • Moreira, Pedro Bertino; Hospital Municipal da Piedade. Rio de Janeiro. BR
  • Dantas, Adalmir Morterá; Universidade Estadual do Rio de Janeiro. Rio de Janeiro. BR
  • Moraes Júnior, Haroldo Vieira de; UFRJ. Rio de Janeiro. BR
Arq. bras. oftalmol ; 70(3): 471-479, maio-jun. 2007. graf, tab
Artigo em Português | LILACS | ID: lil-459835
Biblioteca responsável: BR1.1
RESUMO

OBJETIVO:

Avaliar e correlacionar os picos e a flutuação da pressão intra-ocular verificados na associação da curva ambulatorial com o teste de sobrecarga hídrica com os picos e a flutuação verificados na curva diária de pressão intra-ocular.

MÉTODOS:

A amostra foi constituída de 77 olhos de 77 pacientes divididos em três grupos compostos por 31 olhos de 31 pacientes portadores de glaucoma primário de ângulo aberto, 26 olhos de 26 pacientes com glaucoma de pressão normal e 20 olhos normais de 20 indivíduos.

RESULTADOS:

Houve correlação significativa entre os picos de pressão obtidos na curva diária de pressão intra-ocular e os picos de pressão verificados na curva ambulatorial, no teste de sobrecarga hídrica e na associação da curva ambulatorial com o teste de sobrecarga hídrica. O procedimento em que os picos de pressão apresentaram maior correlação com os picos da curva diária de pressão intra-ocular foi a curva ambulatorial (r²= 0,81), embora não tenha havido diferença estatisticamente significativa com os coeficientes de correlação verificados nos outros métodos. A correlação entre a flutuação da pressão intra-ocular obtida na associação da curva ambulatorial com o teste de sobrecarga hídrica e a flutuação da pressão verificada na curva diária de pressão intra-ocular apresentou uma fraca associação (r²= 0,21).

CONCLUSÃO:

A associação da curva ambulatorial com o teste de sobrecarga hídrica não se mostrou eficaz para predizer os picos e a flutuação da curva diária de pressão intra-ocular. A curva ambulatorial e o teste de sobrecarga hídrica, devem ser analisados separadamente. O procedimento mais eficaz em prever o pico e a flutuação da pressão da curva diária de pressão intra-ocular foi a curva ambulatorial.
ABSTRACT

PURPOSE:

To evaluate and correlate the peaks and the fluctuation of intraocular pressure seen in the association of the ambulatory intraocular pressure curve with the water-drinking test versus the peaks and the fluctuation seen in the daily intraocular pressure curve.

METHODS:

The sample was as follows 77 eyes belonging to 77 patients who were divided into three groups composed of 31 eyes belonging to 31 patients with primary open-angle glaucoma, 26 eyes belonging to 26 patients with normal tension glaucoma and 20 normal eyes belonging to 20 individuals.

RESULTS:

A significant correlation could be observed between the pressure peaks collected from the daily intraocular pressure curve and the pressure peaks seen in the ambulatory intraocular pressure curve, on the water-drinking test, as well as in the association of the ambulatory intraocular pressure curve with the water-drinking test. The procedure which showed the highest rate of correlation between the pressure peaks and the peaks of the daily intraocular pressure curve was the ambulatory intraocular pressure curve (r²= 0.81). However, no statistically significant difference was found between the pressure peaks and the correlation coefficients observed in the other methods. The correlation between the fluctuation of intraocular pressure obtained in the association of the ambulatory intraocular pressure curve with the water-drinking test and the fluctuation of the pressure seen in the daily intraocular pressure curve showed a slight association (r²= 0.21).

CONCLUSIONS:

The association between ambulatory intraocular pressure curve and water-drinking test was not efficient to estimate peaks and the fluctuation of daily intraocular pressure curve. The ambulatory intraocular pressure curve and the water-drinking test must be analyzed separately. When predicting the peak and the fluctuation of the daily intraocular pressure curve, the ambulatory intraocular pressure curve was the most...
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Água / Glaucoma de Ângulo Aberto / Técnicas de Diagnóstico Oftalmológico / Ingestão de Líquidos / Pressão Intraocular Tipo de estudo: Estudo prognóstico / Fatores de risco Limite: Adulto / Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Municipal da Piedade/BR / UFRJ/BR / Universidade Estadual do Rio de Janeiro/BR / Universidade Gama Filho/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Água / Glaucoma de Ângulo Aberto / Técnicas de Diagnóstico Oftalmológico / Ingestão de Líquidos / Pressão Intraocular Tipo de estudo: Estudo prognóstico / Fatores de risco Limite: Adulto / Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Municipal da Piedade/BR / UFRJ/BR / Universidade Estadual do Rio de Janeiro/BR / Universidade Gama Filho/BR
...