Your browser doesn't support javascript.
loading
Doppler tecidual como índice prognóstico em longo prazo na disfunção sistólica do ventrículo esquerdo / Tissue doppler imaging as a long-term prognostic index in left ventricular systolic dysfunction
Saraiva, Roberto Magalhães; Rocha, Rita de Cássia Castelli da; Martins, Adriana Ferraz; Duarte, Dario Marins; Peixoto, Renata da Silva; Castro, Simone Henriques de; Gallicchio, Carla Tavares; Araújo, Andréa Lúcia de; Kaiser, Sérgio Emanuel.
Afiliação
  • Saraiva, Roberto Magalhães; Total Care. Rio de Janeiro. BR
  • Rocha, Rita de Cássia Castelli da; Total Care. Rio de Janeiro. BR
  • Martins, Adriana Ferraz; Total Care. Rio de Janeiro. BR
  • Duarte, Dario Marins; Total Care. Rio de Janeiro. BR
  • Peixoto, Renata da Silva; Total Care. Rio de Janeiro. BR
  • Castro, Simone Henriques de; Total Care. Rio de Janeiro. BR
  • Gallicchio, Carla Tavares; Total Care. Rio de Janeiro. BR
  • Araújo, Andréa Lúcia de; Total Care. Rio de Janeiro. BR
  • Kaiser, Sérgio Emanuel; Total Care. Rio de Janeiro. BR
Arq. bras. cardiol ; 91(2): 85-92, ago. 2008. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-488892
Biblioteca responsável: BR1.1
RESUMO
FUNDAMENTO Parâmetros derivados do Doppler tecidual correlacionam-se com a pressão diastólica final do ventrículo esquerdo (VE) e podem servir como índice prognóstico na insuficiência cardíaca.

OBJETIVO:

Determinar se parâmetros do Doppler tecidual podem predizer eventos em longo prazo em pacientes ambulatoriais com disfunção sistólica do VE.

MÉTODOS:

Estudo retrospectivo envolvendo 73 pacientes (60,9±12,1 anos) que realizaram ecocardiograma Doppler entre março de 2001 e maio de 2004. O evento primário pesquisado foi morte ou hospitalização por piora da insuficiência cardíaca.

RESULTADOS:

O período de seguimento médio foi de 1.367±665 dias. Após análise logística multivariada "stepwise" incluindo os parâmetros ecocardiográficos, a razão entre as velocidades máximas de enchimento do VE e miocárdica no início da diástole (razão E/E'; p=0,0007) e a fração de ejeção do VE (FE; p=0,01) permaneceram como preditores do evento primário. Os pontos de corte ótimos para a previsão do evento primário para a razão E/E' (AUC 0,77; p=0,0001) e FE (AUC 0,68; p=0,006) foram, respectivamente, 12,7 por cento e 30 por cento. Assim, pacientes com razão E/E' > 12,7 (razão de risco=3,8, p=0,001) ou FE <30 por cento (razão de risco=2,3, p=0,03) demonstravam pior prognóstico pela análise da curva de sobrevida. Importante salientar que 47 por cento dos pacientes com FE acima do ponto de corte, mas razão E/E' elevada, apresentaram eventos durante o período estudado.

CONCLUSÃO:

Em pacientes ambulatoriais com disfunção sistólica do VE, a razão E/E' é um importante e independente indicador prognóstico em longo prazo de morte ou hospitalização. Portanto, recomenda-se incluir a medida dessa variável na avaliação rotineira desses pacientes.
ABSTRACT

BACKGROUND:

Tissue Doppler parameters correlate with left ventricular (LV) filling pressure and can be useful as prognostic indexes for patients with heart failure.

OBJECTIVE:

Determine whether tissue Doppler parameters can predict events during long term follow-up of outpatients with LV systolic dysfunction.

MeTHODS:

Retrospective study with 73 patients (aged 60.9±12.1 years) who underwent Doppler echocardiogram between March 2001 and May 2004. The primary endpoint studied was death or hospitalization due to heart failure worsening.

RESULTS:

The mean follow-up period was 1,367±665 days. After logistic stepwise multivariate analysis, including echocardiographic parameters, the ratio of maximal early diastolic filling wave velocity to maximal early diastolic myocardial velocity (E/E` ratio; p=0.0007), and LV ejection fraction (EF; p=0.01) remained significant predictors of the primary outcome. The optimal cutoffs for primary endpoint prediction for E/E' ratio (AUC 0.77; p=0.0001) and EF (AUC 0.68, p=0.006) were respectively 12.7 and 30 percent. Accordingly, patients with E/E' ratio > 12.7 (hazard ratio=3.8, p =0.001) or EF <30 percent (hazard ratio=2.3, p=0.03) had a poorer outcome by survival curve analysis. It is noteworthy that 47 percent of the patients with EF above the optimal cutoff point, but with high E/E' ratio, presented events during follow-up.

CONCLUSION:

E/E' ratio is an important independent long-term prognostic index of death or hospitalization due to worsening heart failure in outpatients with LV systolic dysfunction. Therefore, we recommend the measurement of this variable in the routine evaluation of such patients.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Disfunção Ventricular Esquerda / Insuficiência Cardíaca Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Total Care/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Disfunção Ventricular Esquerda / Insuficiência Cardíaca Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Total Care/BR
...