Your browser doesn't support javascript.
loading
A contralateral eye study comparing apodized diffrative and full diffrative lenses: wavefront analysis and distance and near uncorrected visual acuity
Santhiago, Marcony Rodrigues de; Netto, Marcelo Vieira; Barreto Júnior, Jackson; Gomes, Beatriz de Abreu Fiuza; Schaefer, Arthur; Kara-Junior, Newton.
Afiliação
  • Santhiago, Marcony Rodrigues de; Universidade de São Paulo. Department of Cataract Surgery. São Paulo. BR
  • Netto, Marcelo Vieira; Universidade de São Paulo. Department of Refractive Surgery. São Paulo. BR
  • Barreto Júnior, Jackson; Universidade de São Paulo. Department of Refractive Surgery. São Paulo. BR
  • Gomes, Beatriz de Abreu Fiuza; Universidade Federal do Rio de Janeiro. Department of Ophthalmology. Rio de Janeiro. BR
  • Schaefer, Arthur; Universidade de São Paulo. Department of Cataract Surgery. São Paulo. BR
  • Kara-Junior, Newton; Universidade de São Paulo. Department of Cataract Surgery. São Paulo. BR
Clinics ; 64(10): 953-960, 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-529537
Biblioteca responsável: BR1.1
ABSTRACT

PURPOSE:

To evaluate intraindividual visual acuity, wavefront errors and modulation transfer functions in patients implanted with two diffractive multifocal intraocular lenses.

METHODS:

This prospective study examined 40 eyes of 20 cataract patients who underwent phacoemulsification and implantation of a spherical multifocal ReSTOR intraocular lens in one eye and an aspheric Tecnis ZM900 multifocal intraocular lens in the other eye. The main outcome measures, over a 3-month follow-up period, were the uncorrected photopic distance and near visual acuity and the defocus curve. The visual acuity was converted to logMAR for statistical analysis and is presented in decimal scale. The wavefront error and modulation transfer function were also evaluated in both groups.

RESULTS:

At the 3-month postoperative visit, the mean photopic distance uncorrected visual acuity (UCVA) was 0.74 ± 0.20 in the ReSTOR group and 0.76 ± 0.22 in the Tecnis group (p=0.286). The mean near UCVA was 0.96 ± 0.10 in the ReSTOR group and 0.93 ± 0.14 in the Tecnis group (p=0.963). The binocular defocus curve showed measurements between the peaks better than 0.2 logMAR. The total aberration, higher-order aberration and coma aberration were not significantly different between the groups. The spherical aberration was significantly lower in the Tecnis group than in the ReSTOR group. (p=0.004). Both groups performed similarly for the modulation transfer function.

CONCLUSION:

The ReSTOR SN60D3 and Tecnis ZM 900 intraocular lenses provided similar photopic visual acuity at distance and near. The diffractive intraocular lenses studied provided a low value of coma and spherical aberrations, with the Tecnis intraocular lens having a statistically lower spherical aberration compared to the ReSTOR intraocular lens. In the 5 mm pupil diameter analyses, both intraocular lens groups showed similar modulation transfer functions.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Erros de Refração / Sensibilidades de Contraste / Lentes Intraoculares Tipo de estudo: Estudo observacional Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Clinics Assunto da revista: Medicina Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio de Janeiro/BR / Universidade de São Paulo/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Erros de Refração / Sensibilidades de Contraste / Lentes Intraoculares Tipo de estudo: Estudo observacional Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Clinics Assunto da revista: Medicina Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio de Janeiro/BR / Universidade de São Paulo/BR
...