Your browser doesn't support javascript.
loading
Efectos de la eliminación de la tensión mediante puntos epineurales: estudio comparativo empleando diferentes técnicas de sutura en un modelo animal / Effects of tension elimination by using epineural anchoring stitches: a comparative study employing different techniques of suture in an experimental model
Bustamante, Jorge; Socolovsky, Mariano; Emmerich, Juan; Pennini, María Gabriela; Lausada, Natalia; Domitrovic, Luis; Fernández, Eduardo; Martins, Roberto.
Afiliação
  • Bustamante, Jorge; Universidad Nacional de La Plata. Facultad de Medicina. Laboratorio de Transplantes. La Plata. AR
  • Socolovsky, Mariano; Universidad de Buenos Aires. Hospital de Clínicas. Instituto de Neurociencias. Servicio de Neurocirugía. Buenos Aires. AR
  • Emmerich, Juan; Hospital de Pediatría Sor María Ludovica. La Plata. AR
  • Pennini, María Gabriela; Hospital de Pediatría Sor María Ludovica. La Plata. AR
  • Lausada, Natalia; Universidad Nacional de La Plata. Facultad de Medicina. Laboratorio de Transplantes. La Plata. AR
  • Domitrovic, Luis; Universidad de Buenos Aires. Hospital de Clínicas. Instituto de Neurociencias. Servicio de Neurocirugía. Buenos Aires. AR
  • Fernández, Eduardo; Universittá Católica di Roma. Departamento de Neurocirugía. Roma. IT
  • Martins, Roberto; Universidad de Sao Paulo. Hospital das Clínicas. Departamento de Neurocirugía. Sao Paulo. BR
Rev. argent. neurocir ; 23(2): 71-76, abr.-jun. 2009. ilus
Artigo em Espanhol | LILACS | ID: lil-560006
Biblioteca responsável: AR423.1
RESUMEN
Objetivo. Documentar la utilidad de una técnica de sutura epineural bajo tensión, en comparación con la sutura mediante injerto interpuesto y la neurorrafia termino-terminal, en un estudio realizado en un modelo experimental animal (rata Wistar). Material y Método. Un lote de 20 animales, considerados como 40 unidades fisiológicas independientes a nivel del miembro inferior, fueron separados en 4 grupos de 10 en el primero se realizó una sutura bajo tensión con puntos epineurales a nivel del nervio ciático luego de resecar 4 mm de nervio. En el segundo se realizó una sutura término-terminal sin tensión, en el tercero se colocó un puente de injerto autólogo de 4 mm de extensión y el cuarto fue utilizado como control. A los 90 días de efectuados los procedimientos, se reexpusieron las zonas operadas y se documentaron las respuestas fisiológicas a los diferentes tipos de sutura mediante potenciales de acción de músculo (PAM) y nervio (PAN). Resultados. El promedio de la velocidad de conducción para la sutura simple fue el mejor de los tres grupos operados (14,60 mm/ ms), aunque peor que el control (19,31 mm/ms). La sutura a tensión mediante puntos epineurales (12,02 mm/ms) demostró resultados neurofisiológicos superiores que cuando se utilizó injerto autólogo (11,09 mm/ms). Conclusión. El presente estudio demuestra que si se logra coaptar un nervio ciático de rata mediante sutura epineural con puntos distales a la línea de neurorrafia, sus resultados son mejores que al emplear injerto. Sin embargo, estos resultados, obtenidos en un modelo de animal pequeño, deben ser cuidadosamente extrapolados a la práctica quirúrgica habitual.
ABSTRACT
Objective. To measure the utility of this technique, in comparison with interposed grafts and termino-terminal neuroraphy, all applied in an experimental model (Wistar rat).Materials and method. 20 rats were used in both sides (40 legs, each one considered as independent physiological units, were grouped in four groups in the first one, a section of thesciatic nerve was performed, a segment 4mm long was discarded and an epineural suture with distal anchoring stitches was done under slight tension. In the second group a tensionlesstermino-terminal neuroraphy was performed after sciatic nerve section. In the third group a 4 mm long graft was employed and the fourth was used as control. 90 days after this procedure, the animals were reoperated and muscle and nerve action potentialswere recorded in both sides. Results. The mean conduction velocity for the simple suture was higher than the other two groups, but lower than the control(19,31 mm/ms). Neuroraphy with epineural stitches (12,02 mm/ms) was better than when an autologous nerve graft was employed (11,09 mm/ms).Conclusion. This study demonstrates that a good result can be obtained if a nerve is sutured under slight tension, employing epineural anchoring stitches. Nevertheless, more studies shouldbe performed before applying these results to human nerve suture.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Técnicas de Sutura / Ratos Wistar Idioma: Espanhol Revista: Rev. argent. neurocir Assunto da revista: Neurocirurgia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Argentina / Brasil / Itália Instituição/País de afiliação: Hospital de Pediatría Sor María Ludovica/AR / Universidad Nacional de La Plata/AR / Universidad de Buenos Aires/AR / Universidad de Sao Paulo/BR / Universittá Católica di Roma/IT
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Técnicas de Sutura / Ratos Wistar Idioma: Espanhol Revista: Rev. argent. neurocir Assunto da revista: Neurocirurgia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Argentina / Brasil / Itália Instituição/País de afiliação: Hospital de Pediatría Sor María Ludovica/AR / Universidad Nacional de La Plata/AR / Universidad de Buenos Aires/AR / Universidad de Sao Paulo/BR / Universittá Católica di Roma/IT
...