Your browser doesn't support javascript.
loading
Escore eletrocardiográfico para avaliação de isquemia miocárdica: aplicação em testes ergométricos sequenciais para avaliação do fenômeno do aquecimento / Electrocardiographic score for myocardial ischemia evaluation: application in sequential exercise tests for warm-up phenomenon evaluation
São Paulo; s.n; 2009. [69] p.
Tese em Português | LILACS | ID: lil-587418
Biblioteca responsável: BR66.1
Localização: BR66.1; W4.DB8, U18es, FM-2, 2009
RESUMO
O tempo para 1,0mm de depressão do segmento ST (T-1,0mm) adotado para caracterizar o fenômeno do aquecimento, uma expressão do precondicionamento isquêmico (PCI), em testes ergométricos sequenciais é consistente e reprodutível, porém, possui várias limitações. O objetivo deste estudo foi aplicar um escore eletrocardiográfico de isquemia miocárdica em testes ergométricos sequenciais comparando com o clássico índice T-1,0mm. Avaliamos 61 pacientes, com idade média de 62,2+7,5 anos, 86,9% homens, portadores de diabetes mellitus tipo 2 e coronariopatia multiarterial. Foram analisados 151 exames, destes 116 de pacientes completaram as duas fases de avaliação. A primeira fase compreendia dois testes ergométricos sequenciais para documentação do PCI e a segunda fase, após 1 semana, mais dois testes sob efeito de repaglinida oral. Dois observadores aplicaram o escore de forma cega. Observou-se concordância perfeita inter e intraobservador (Kendall Tau-b = 0,96, p<0,0001, Kendall Tau-b=0,98, p<0,0001, respectivamente). Os valores de sensibilidade, especificidade, valor preditivo negativo, valor preditivo positivo e acurácia, foram respectivamente de 72,41%, 89,29%, 75,8%, 87,5% e 81%. Concluímos que o escore de isquemia é um método consistente e reprodutível para documentação do fenômeno do aquecimento, representando uma alternativa factível ao índice T-1,0mm.
ABSTRACT
The time to 1.0mm ST-segment depression (T-1.0mm), adopted to document the warm-up phenomenon, an expression of the ischemic preconditioning (IPC), during sequential exercise tests is considered reliable and reproductible, although with several limitations. The main goal of this study was to apply an electrocardiographic ischemic myocardium score to sequential exercise tests, comparing with the standard T-1.0mm. We evaluated 61 patients, mean age 62,2+7,5 years-old, 86.9% male, with type 2 diabetes mellitus and multivessel coronary disease. We analyzed 151 exercise tests, being 116 tests from patients who fulfilled the two phases of the study. The first phase enrolled the patients for two sequential exercise tests to document the IPC and the second phase, after 1 week, two additional sequential exercise tests were performed under repaglinide treatment. We observed a perfect concordance inter and intraobserver (Kendall Tau-b=0.96, p<0.0001; Kendall Tau-b=0,98, p<0,0001, respectively). The sensibility, specificity, positive predictive value and negative predictive value were also determined 72.41%, 89.29%, 75.8%, 87.5% and 81%, respectively. In conclusion, the electrocardiographic ischemic score is a consistent and reproductible tool to document the warm-up phenomenon, representing a reliable alternative to the T-1.0mm.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Isquemia Miocárdica / Precondicionamento Isquêmico / Doença das Coronárias / Eletrocardiografia / Teste de Esforço Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Português Ano de publicação: 2009 Tipo de documento: Tese
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Isquemia Miocárdica / Precondicionamento Isquêmico / Doença das Coronárias / Eletrocardiografia / Teste de Esforço Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Português Ano de publicação: 2009 Tipo de documento: Tese
...