Medida do átrio esquerdo em pacientes com suspeita de insuficiência cardíaca com fração de ejeção normal / Left atrium measurement in patients suspected of having heart failure with preserved ejection fraction
Jorge, Antônio José Lagoeiro; Ribeiro, Mario Luiz; Rosa, Maria Luiza Garcia; Licio, Fernanda Volponi; Fernandes, Luiz Cláudio Maluhy; Lanzieri, Pedro Gemal; Jorge, Bruno Afonso Lagoeiro; Brito, Flavia Oliveira Xavier; Mesquita, Evandro Tinoco.
Afiliação
  • Jorge, Antônio José Lagoeiro; Universidade Federal Fluminense. Niterói. BR
  • Ribeiro, Mario Luiz; Universidade Federal Fluminense. Niterói. BR
  • Rosa, Maria Luiza Garcia; Universidade Federal Fluminense. Niterói. BR
  • Licio, Fernanda Volponi; Universidade Federal Fluminense. Niterói. BR
  • Fernandes, Luiz Cláudio Maluhy; Universidade Federal Fluminense. Niterói. BR
  • Lanzieri, Pedro Gemal; Universidade Federal Fluminense. Niterói. BR
  • Jorge, Bruno Afonso Lagoeiro; Universidade Federal Fluminense. Niterói. BR
  • Brito, Flavia Oliveira Xavier; s.af
  • Mesquita, Evandro Tinoco; Universidade Federal Fluminense. Niterói. BR
Arq. bras. cardiol ; 98(2): 175-181, fev. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-614509
Biblioteca responsável: BR1.1
RESUMO
FUNDAMENTO O modelo fisiopatológico da insuficiência cardíaca com fração de ejeção normal (ICFEN) está centrado na presença de disfunção diastólica, o que ocasiona mudanças estruturais e funcionais no átrio esquerdo (AE). A medida do tamanho do AE pode ser utilizada como um marcador da presença de ICFEN, sendo um indicador da elevação crônica da pressão de enchimento do VE, cuja mensuração é de fácil obtenção.

OBJETIVO:

Estimar a acurácia da medida do tamanho do AE, utilizando os valores indexados do diâmetro e do volume do AE para o diagnóstico de ICFEN em pacientes ambulatoriais.

MÉTODOS:

Estudamos 142 pacientes (67,3 ± 11,4 anos, 75 por cento de mulheres) com suspeita de IC, os quais foram divididos em dois grupos com ICFEN (n = 35) e sem ICFEN (n = 107).

RESULTADOS:

A função diastólica, avaliada pelo ecodopplercardiograma, mostrou diferença significativa entre os dois grupos em relação aos parâmetros que avaliaram o relaxamento ventricular (E' 6,9 ± 2,0 cm/s vs. 9,3 ± 2,5 cm/s - p < 0,0001) e a pressão de enchimento do VE (relação E/E' 15,2 ± 6,4 vs. 7,6 ± 2,2 - p < 0,0001). O ponto de coorte do volume do AE indexado (VAE-I) de 35 mL/m² foi o que melhor se correlacionou com o diagnóstico de ICFEN, demonstrando sensibilidade de 83 por cento, especificidade de 83 por cento e acurácia de 83 por cento. Já o ponto de coorte do diâmetro ântero-posterior do AE indexado (DAE-I) de 2,4 cm/m² apresentava sensibilidade de 71 por cento, especificidade de 66 por cento e acurácia de 67 por cento.

CONCLUSÃO:

Para o diagnóstico de ICFEN em pacientes ambulatoriais, o VAE-I é o método mais acurado em comparação ao DAE-I. Na avaliação ecocardiográfica, a medida do tamanho do AE deveria ser substituída pela medida indexada do volume. (Arq Bras Cardiol. 2011; [online].ahead print, PP.0-0).
ABSTRACT

BACKGROUND:

The pathophysiological model of heart failure (HF) with preserved ejection fraction (HFPEF) focuses on the presence of diastolic dysfunction, which causes left atrial (LA) structural and functional changes. The LA size, an indicator of the chronic elevation of the left ventricular (LV) filling pressure, can be used as a marker of the presence of HFPEF, and it is easily obtained.

OBJECTIVE:

To estimate the accuracy of measuring the LA size by using indexed LA volume and diameter (ILAV and ILAD, respectively) for diagnosing HFPEF in ambulatory patients.

METHODS:

This study assessed 142 patients (mean age, 67.3 ± 11.4 years; 75 percent of the female sex) suspected of having HF, divided into two groups with HFPEF (n = 35) and without HFPEF (n = 107).

RESULTS:

The diastolic function, assessed by use of Doppler echocardiography, showed a significant difference between the groups regarding the parameters assessing ventricular relaxation (E' 6.9 ± 2.0 cm/s vs. 9.3 ± 2.5 cm/s; p < 0.0001) and LV filling pressure (E/E' ratio 15.2 ± 6.4 vs. 7.6 ± 2.2; p < 0.0001). The ILAV cutoff point of 35 mL/m2 best correlated with the diagnosis of HFPEF, showing sensitivity, specificity, and accuracy of 83 percent. The ILAD cutoff point of 2.4 cm/m2 showed sensitivity of 71 percent, specificity of 66 percent, and accuracy of 67 percent.

CONCLUSION:

For diagnosing HFPEF in ambulatory patients, the ILAV proved to be a more accurate parameter than ILAD. On echocardiographic assessment, ILAV, rather than ILAD, should be routinely measured. (Arq Bras Cardiol. 2011; [online].ahead print, PP.0-0).
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Volume Sistólico / Disfunção Ventricular Esquerda / Insuficiência Cardíaca Diastólica Tipo de estudo: Estudo diagnóstico / Estudo de avaliação Limite: Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal Fluminense/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Volume Sistólico / Disfunção Ventricular Esquerda / Insuficiência Cardíaca Diastólica Tipo de estudo: Estudo diagnóstico / Estudo de avaliação Limite: Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal Fluminense/BR
...