Your browser doesn't support javascript.
loading
Análise da confiabilidade do teste clínico de queda do navicular / Reliability analysis of the clinical application of the navicular drop test
Sabino, George Schayer; Rocha, Ivan Casas; Guimarães, Cristiano Queiroz; Alcântara, Marcus Alessandro de; Felício, Diogo Carvalho.
Afiliação
  • Sabino, George Schayer; Universidade Federal de Minas Gerais. BR
  • Rocha, Ivan Casas; s.af
  • Guimarães, Cristiano Queiroz; Universidade Federal de Minas Gerais. BR
  • Alcântara, Marcus Alessandro de; Universidade Federal de Minas Gerais. BR
  • Felício, Diogo Carvalho; s.af
Fisioter. mov ; 25(2): 301-309, abr.-jun. 2012. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-640242
Biblioteca responsável: BR16.1
RESUMO

Introdução:

A utilização de medidas confiáveis e práticas são necessárias para a tomada de decisões clínicas.O Teste da Queda do Navicular (TQN) fornece informações importantes na avaliação dos membros inferiores. Assim, os objetivos do presente estudo foram verificar a confiabilidade do TQN, conforme realizado na clínica, e analisar uma forma de minimizar a interferência do avaliador.

Materiais e métodos:

Participaram do estudo 15 indivíduos (30 pés), selecionados por conveniência. O TQN foi aplicado de forma independente por dois examinadores experientes na realização do teste, o qual foi realizado apenas uma vez em cada , utilizando-se um paquímetro de plástico. Foi realizada uma análise descritiva dos dados. Para avaliação da confiabilidade inter examinadores, foi utilizado o índice de correlação intraclasse (ICC₂,₁) e a discrepância das medidas entre avaliadores foi analisada pelo erro típico da medição.

Resultados:

A média e o desvio padrão para o primeiro e segundo examinador foram 8,7 ± 5,3 e 9,7 ± 4,7 milímetros. O teste apresentou excelente confiabilidade interexaminador (ICC = 0,93). O erro típico da medição foi 2,16 milímetros.

Conclusão:

Os procedimentos para minimizar a interferência do avaliador resultaram, contraditoriamente, em uma piora dos índices de confiabilidade. O TQN pode ser simplificado por meio do uso de instrumentos comuns na clínica e registrado a partir de uma única medida. Mesmo apresentando boa confiabilidade, o TQN apresenta um erro típico da medida, que deve ser levado em consideração para a tomada de decisão. Mudanças no teste, por vezes necessárias em um ambiente clínico, deverão ser analisadas quanto à conservação de suas propriedades
ABSTRACT

INTRODUCTION:

Reliable and practical measures are necessary for making clinical decisions. The Navicular Drop Test (NDT) provides important information during evaluation of lower limbs. The purpose of the present article was to assess the psychometric properties of NDT as usually done in clinical environment, and to analyze a way to minimize the evaluator interference. MATERIALS AND

METHODS:

Fifteen people (30 feet), selected by convenience, participated. The NDT was performed independently by two investigators experienced in the test realization. The test was performed once in each foot, using a plastic caliper. Descriptive analysis of data was done. In order to evaluate the inter-examiner reliability, intraclass correlation index (ICC2,1) was used. The divergence between the measures was examined by the typical error measurement.

RESULTS:

The mean and standard deviation for the first and second examiner was 8.7 ± 5.3 and 9.7 ± 4.7 mm. The test showed excellent inter-examiner reliability (ICC = 0.93). The typical error of measurement was 2.16 mm.

CONCLUSION:

The procedures to minimize the interference of evaluator, paradoxically, showed worse indices of reliability. The NDT can be simplified by using common clinical tools and recorded from a single measure. Even though it showed a good reliability, the NDT contains a typical error of measurement which has to be considered for decision making. Changes in the test, sometimes required in a dynamic clinical environment, should be analyzed for maintenance of test properties.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Exame Físico / Acidentes por Quedas / Extremidade Inferior / Pé Tipo de estudo: Estudo prognóstico Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Fisioter. mov Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Exame Físico / Acidentes por Quedas / Extremidade Inferior / Pé Tipo de estudo: Estudo prognóstico Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Fisioter. mov Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR
...