Your browser doesn't support javascript.
loading
Segurança e eficácia dos stents farmacológicos eluidores de biolimus com polímero biodegradável: análise do registro EINSTEIN (Evaluation of Next-generation drug-eluting STEnt IN patients with coronary artery disease) / Safety and efficacy of biolimus-eluting stent with biodegradable polymer: insights from EINSTEIN (Evaluation of Next-generation drug-eluting STEnt IN patients with coronary artery disease) Registry
Souza, Cristiano Freitas de; El Mouallem, Anwar Mohamed; Brito Júnior, Fábio Sândoli de; Abizaid, Alexandre Antônio Cunha; Almeida, Breno Oliveira; Almeida, Amanda Gonçalves; Nascimento, Teresa Cristina Dias Cunha; Perin, Marco Antonio; Caixeta, Adriano.
Afiliação
  • Souza, Cristiano Freitas de; Hospital Israelita Albert Einstein. São Paulo. BR
  • El Mouallem, Anwar Mohamed; Hospital Israelita Albert Einstein. São Paulo. BR
  • Brito Júnior, Fábio Sândoli de; Hospital Israelita Albert Einstein. São Paulo. BR
  • Abizaid, Alexandre Antônio Cunha; Hospital Israelita Albert Einstein. São Paulo. BR
  • Almeida, Breno Oliveira; Hospital Israelita Albert Einstein. São Paulo. BR
  • Almeida, Amanda Gonçalves; Hospital Israelita Albert Einstein. São Paulo. BR
  • Nascimento, Teresa Cristina Dias Cunha; Hospital Israelita Albert Einstein. São Paulo. BR
  • Perin, Marco Antonio; Hospital Israelita Albert Einstein. São Paulo. BR
  • Caixeta, Adriano; Hospital Israelita Albert Einstein. São Paulo. BR
Einstein (Säo Paulo) ; 11(3): 350-356, jul.-set. 2013. graf, tab
Artigo em Português | LILACS | ID: lil-688640
Biblioteca responsável: BR1.1
RESUMO

OBJETIVO:

Avaliar a incidência de eventos adversos cardíacos maiores (morte cardíaca, infarto agudo do miocárdio ou necessidade de nova revascularização do vaso-alvo) em 1 ano em pacientes do "mundo real".

MÉTODOS:

O registro EINSTEIN é um estudo observacional prospectivo, unicêntrico, que incluiu consecutivamente 103 pacientes (152 lesões) tratados com o stent BiomatrixTM, eluidor de biolimus A9 e polímero biodegradável.

RESULTADOS:

A média das idades foi de 65,0±12,4 anos; o gênero masculino representou 83,5% dos pacientes; e 37,9% deles eram diabéticos. Em 1 ano, eventos adversos cardíacos maiores ocorreram em 11,7% dos pacientes, incluindo 2,9% de morte cardíaca, 4,9% de infarto agudo do miocárdio sem supradesnivelamento do segmento ST e 3,9% de revascularização do vaso-alvo. Trombose de stent esteve presente em apenas 1% (1 paciente) após o seguimento clínico de 1 ano.

CONCLUSÃO:

O presente registro sugere que os novos stents farmacológicos eluidores de biolimus A9 com polímero biodegradável são seguros e eficazes em pacientes da prática clínica diária, com baixas taxas de eventos adversos cardíacos maiores no longo prazo.
ABSTRACT

OBJECTIVE:

To evaluate the incidence of major adverse cardiac events (cardiac death, or acute myocardial infarct, or target vessel revascularization) at one year in "real world" patients.

METHODS:

The EINSTEIN registry is an observational, prospective, single center study that consecutively included 103 patients (152 lesions) treated with the BiomatrixTM stent, a biolimus A9-eluting stent with biodegradable polymer.

RESULTS:

The mean age was 65.0±12.4 years; male gender represented 83.5% of the patients; and 37.9% of them were diabetic. At one-year, major adverse cardiac events occurred in 11.7% of the patients, including 2.9% of cardiac death, 4.9% of with non ST- segment elevation acute myocardial infarction, and 3.9% of target vessel revascularization. Stent thrombosis occurred in only 1% (1 patient) at one-yearfollow-up.

CONCLUSION:

The present Registry suggests that new generation biolimus A9 drug-eluting stents are safe and effective in a "real world", all-comers patients, showing low rates of major cardiac adverse events on long-term follow-up.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Polímeros / Materiais Biocompatíveis / Doença da Artéria Coronariana / Sistemas de Liberação de Medicamentos / Sirolimo / Stents Farmacológicos Tipo de estudo: Estudo observacional Idioma: Português Revista: Einstein (Säo Paulo) Assunto da revista: Medicina Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Israelita Albert Einstein/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Polímeros / Materiais Biocompatíveis / Doença da Artéria Coronariana / Sistemas de Liberação de Medicamentos / Sirolimo / Stents Farmacológicos Tipo de estudo: Estudo observacional Idioma: Português Revista: Einstein (Säo Paulo) Assunto da revista: Medicina Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Israelita Albert Einstein/BR
...