Your browser doesn't support javascript.
loading
Comparação de diferentes testes funcionais de membros inferiores em pacientes com doença pulmonar obstrutiva crônica: há concordância entre eles? / Comparison of different functional tests of lower limbs in patients with chronic obstructive pulmonary disease: there is concordance between them?
Pessoa, Bruna Varanda; Jamami, Mauricio; Basso, Renata Pedrolongo; Regueiro, Eloisa Maria Gatti; Oliveira Junior, Antônio Delfino de; Lorenzo, Valéria Amorim Pires Di.
Afiliação
  • Pessoa, Bruna Varanda; Universidade Federal de São Carlos. São Carlos. BR
  • Jamami, Mauricio; Universidade Federal de São Carlos. São Carlos. BR
  • Basso, Renata Pedrolongo; Universidade Federal de São Carlos. São Carlos. BR
  • Regueiro, Eloisa Maria Gatti; Universidade Federal de São Carlos. São Carlos. BR
  • Oliveira Junior, Antônio Delfino de; s.af
  • Lorenzo, Valéria Amorim Pires Di; Universidade Federal de São Carlos. São Carlos. BR
Fisioter. mov ; 26(3): 491-502, jul.-set. 2013. graf, tab
Artigo em Português | LILACS | ID: lil-688653
Biblioteca responsável: BR16.1
RESUMO

INTRODUÇÃO:

Pacientes com Doença Pulmonar Obstrutiva Crônica (DPOC) apresentam diminuição da capacidade funcional, tornando imprescindível a sua avaliação por meio de testes físicos funcionais.

OBJETIVOS:

Comparar, em pacientes com DPOC, saturação periférica de oxigênio (SpO2), dispneia e fadiga de membros inferiores (MMII) nos testes de caminhada de seis minutos em corredor (TC6) e em pista oval (TC6Po), do degrau de seis minutos (TD6) e de sentar-e-levantar da cadeira de dois minutos (TSL). Além disso, pretende-se verificar se há correlação e concordância dessas variáveis entre o TC6 e os demais testes.

MATERIAIS E MÉTODOS:

Foram avaliados 11 pacientes com DPOC (71 ± 8 anos, VEF1 < 80% previsto) por meio dos testes.

RESULTADOS:

Na análise intertestes, não se observaram diferenças significativas nos deltas da SpO2, dispneiadispneia) e fadiga de MMII (ΔfadigaMMII). Constatou-se correlação significante, mas não concordância entre os menores valores da SpO2 no TC6 com os menores valores da SpO2 nos TC6Po, TD6 e TSL, sendo a média da diferença entre as médias com ± 1,96 desvio padrão 0,8 ± 3,5; -1,9 ± 3,5 e -2,5 ± 4,6, respectivamente; entre Δdispneia e ΔfadigaMMII no TC6 com Δdispneia e ΔfadigaMMII no TC6Po 0,0 ± 1,0 e 0,4 ± 0,8, respectivamente; e do ΔfadigaMMII no TC6 com ΔfadigaMMII no TSL 0,1 ± 1,1.

CONCLUSÃO:

Os testes funcionais produziram respostas de oxigenação e perceptuais de esforço semelhantes em magnitude. Entretanto, de acordo com as variáveis analisadas, não foi encontrada concordância entre o TC6 com os demais testes, pelas grandes variações dos limites de concordância e grande variação interindividual, assim o TC6Po, TD6 e TSL não substitui o TC6.
ABSTRACT

INTRODUCTION:

Patients with Chronic Obstructive Pulmonary Disease (COPD) have reduced functional capacity, becoming indispensable to their evaluation through functional physical tests.

OBJECTIVE:

To compare the peripheral oxygen saturation (SpO2), dyspnea and fatigue of the lower limbs (LL), between the six-minute walk test in hallway (6MWT) and the of oval track (6MWToT), the six-minute step test (6MST) and the sit--to-stand test (STST), in patients with COPD; also verifying correlate and concordance of these variables between 6MWT and other tests. MATERIALS AND

METHODS:

Ten patients with COPD (72 ± 7 years, FEV1 < 80% predicted) were assessed using the functional tests.

RESULTS:

In the inter-tests analysis, there was no significant difference in SpO2 and in the change in dyspneadyspnea) and fatigue in the lower-limbs (ΔfatigueLL) between rest and exercise of peak (Δ). Significant correlation were observed, but no concordance between the lowest values of SpO2 in the 6MWT with lowest values of SpO2 in 6MWToT, 6MST and STST, and the mean of difference between the mean with standard deviation ± 1.96 0.8 ± 3.5%, -1.9 ± 3.5% and -2.5 ± 4.6%, respectively; and between Δdyspnea and ΔfatigueLL in the 6MWT with the Δdyspnea and ΔfatigueLL in the 6MWToT 0.0 ± 1.0 and 0.4 ± 0.8, respectively; and ΔfatigueLL in the 6MWT with ΔfatigueLL in the STST 0.1 ± 1.1.

CONCLUSION:

The functional tests assess oxygenation and perceived effort responses similar in magnitude. However, according to the variables analyzed, weren't found correlation between the 6MWT with the 6MWToT, 6MST and STST, by the large variations in the limits of agreement and large interindividual variation, thereby the 6MWToT, 6MST and STST and doesn't replace the 6MWT.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Tolerância ao Exercício / Doença Pulmonar Obstrutiva Crônica / Dispneia / Teste de Esforço Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Português Revista: Fisioter. mov Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Carlos/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Tolerância ao Exercício / Doença Pulmonar Obstrutiva Crônica / Dispneia / Teste de Esforço Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Português Revista: Fisioter. mov Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Carlos/BR
...